Upload
dokhuong
View
285
Download
20
Embed Size (px)
Citation preview
Our Vision
Since 1992, Allied International SARL has been generating and providingPower Solutions to partnering clients in more than 30 countries;
“We care. You trust. We deliver”
Allied International SARL strives to conduct its business with the highest standards
of Quality, Ethics, and Integrity. It commits itself to continuous human and technological
developments.
After consolidating its competitive position in the market and establishing a strong
reference list in the Telecom Sector; to name but a few, Orascom Group, MTN,
We c a r e .
You trust.
We deliver
QUOTE
Quality means doing it right when no one is looking (H.Ford)
Allied International SARL differentiates itself from the pack with lasting and mutually beneficail relationships, built on Care, Trust and Timeliness with both suppliers and clients;From here stems our motto:
VivaCell, Asiacell, Zain,
Eaton Tower, American
Tower, Allied International
extended its focus and
know how into larger
power solutions and new
market boundaries.
Back in 2012, and on the verge of its 25th Anniversary, A l l i e dInternational launched its Network of partnering Exclusive Agents Network,under the name of PowerMet International,
whose focus is on the selling, maintenance, renting and servicing Allied International Gensets ranging from 5 to 10,000 KVA.
Genset Product Portfolio
The current portfolio of Allied International SARL includes Gensets from 5 to 3000 KVA, in Open Sets or with Soundproof Canopies (65 & 75 db @ 1 meter)
Lister from 5 to 20 KVA
VM from 20 to 60 KVA
Perkins from 9 to 2500 KVA
Cummins from 25 to 2000 KVA
Genmet Series from 5 to 700 KVA
Allied International is an approved OEM by Perkins, Cummins, Doosan, MAXXFORCE, VM, Lister Petter, Meccalte Stamford & WEG.
RANGE OF GENSETS
Generating Sets50 Hz - Range 1 - From 9 KVA to 20 KVA
Genset Engine Alternator Rating @ 3x400V, Fuel #of Aspiration Dimensions Weight
Model Model 50Hz, 1500rpm Consumption cylinders (cm) (kg)
Prime Standby g/kWh - (L/h) Open Type
MP9D-S 403D-11G PI044E 9 KVA 9.9 KVA 257 - (2.3) 3-L Natural 145x76x111.5 420
MP9A-S 403A-11G1 PI044E 9 KVA 9.9 KVA 257 - (2.3) 3-L Natural 145x76x108.7 488
MP13D-S 403D-15G PI044F 12.5 KVA 13.75 KVA 252 - (2.8) 3-L Natural 145x76x120.6 498
MP13A-S 403A-15G1 PI044F 12.5 KVA 13.75 KVA 252 - (2.8) 3-L Natural 145x76x120.6 498
MP20D-S 404D-22G PI144D 20 KVA 22 KVA 240 - (4.8) 4-L Natural 145x76x125.5 572.5
MP20A-S 404A-22G1 PI144D 20 KVA 22 KVA 238 - (4) 4-L Natural 145x76x125.5 572.5
Diesel EngineGenerating Sets
Powered by Perkins Stamford
Genset Engine Alternator Rating @ 3x400V, Fuel #of Aspiration Dimensions Weight
Model Model 50Hz, 1500rpm Consumption cylinders (cm) (kg)
Prime Standby g/kWh - (L/h) Open Type
MP9D-M 403D-11G ECP3-1L/4 9 KVA 9.9 KVA 257 - (2.3) 3-L Natural 145x76x111.5 422
MP9A-M 403A-11G1 ECP3-1L/4 9 KVA 9.9 KVA 257 - (2.3) 3-L Natural 145x76x108.7 490
MP13D-M 403D-15G ECP3-2L/4 13 KVA 14.3 KVA 252 - (2.8) 3-L Natural 145x76x120.6 500
MP13A-M 403A-15G1 ECP3-2L/4 13 KVA 14.3 KVA 252 - (2.8) 3-L Natural 145x76x120.6 500
MP15-M 403A-15G2 ECP3-3L/4 15 KVA 16.5 KVA NA 3-L Natural 145x76x120.8 549
MP20D-M 404D-22G ECO28-1L/4 20 KVA 22 KVA 240 - (4.8) 4-L Natural 145x76x125.5 575
MP20A-M 404A-22G1 ECO28-1L/4 20 KVA 22 KVA 238 - (4) 4-L Natural 145x76x125.5 575
Genset Engine Alternator Rating @ 3x400V, Fuel #of Aspiration Dimensions Weight
Model Model 50Hz, 1500rpm Consumption cylinders (cm) (kg)
Prime Standby (L/h) Open Type
MV20 SUN 2105E2 19 KVA 21 KVA 2.8 2-L Natural 126x70x105 500
15 KW 17KW
Powered by Perkins Meccalte
Powered by VM
Generating Sets50 Hz - Range 2 - From 30 KVA to 60 KVA
Genset Engine Alternator Rating @ 3x400V, Fuel #of Aspiration Dimensions Weight
Model Model 50Hz, 1500rpm Consumption cylinders (cm) (kg)
Prime Standby g/kWh - (L/h) Open Type
MP27-S 1103A- 33G PI144F 27.5 KVA 30KVA NA - (5.4) 3-L Natural 180x93x126 811
MP30-S 1103A- 33G PI144G 30 KVA 33KVA NA - (5.4) 3-L Natural 180x93x126 822
MP40-S 1103A-33TG1 PI144J 40 KVA 44 KVA NA - (8.2) 3-L Turbocharged 180x93x126 809
& A/A
MP42-S 1103A-33TG1 PI144K 42.5 KVA 46.5 KVA NA - (8.2) 3-L Turbocharged 180x93x126 818
& A/A
MP45-S 1103A-33TG1 UC224D 45 KVA 50 KVA NA - (8.2) 3-L Turbocharged 180x93x126 955
& A/A
MP60-S 1103A-33TG2 UC224E 60 KVA 66 KVA NA - (10.4) 3-L Turbocharged 180x93x126 981
& A/A
Powered by Perkins Stamford
Genset Engine Alternator Rating @ 3x400V, Fuel #of Aspiration Dimensions Weight
Model Model 50Hz, 1500rpm Consumption cylinders (cm) (kg)
Prime Standby g/kWh - (L/h) Open Type
MP30-M 1103A- 33G ECP28- VL/4 30 KVA 33 KVA NA - (5.4) 3-L Natural 180x93x126 827
MP42-M 1103A- 33TG1 ECO32-3S/4 40 KVA 44 KVA NA - (8.2) 3-L Turbocharged 180x93x126 884
MP45-M 1103A- 33TG1 ECO32- 1L/ 4 45 KVA 49.5 KVA NA - (8.2) 3-L Turbocharged 180x93x126 918
MP60-M 1103A- 33TG2 ECO32- 2L/4 60 KVA 66 KVA NA - (10.4) 3-L Turbocharged 180x93x126 952
Genset Engine Alternator Rating @ 3x400V, Fuel #of Aspiration Dimensions Weight
Model Model 50Hz, 1500rpm Consumption cylinders (cm) (kg)
Prime Standby g/kWh - (L/h) Open Type
MC25-S X2.5-G2 (India) PI144E 25KVA 27.5KVA NA - (4.8) 3-L Natural 180x93x124.7 605
MC35-S X3.3-G1 (India) PI144H 35 KVA 38.5 KVA NA - (6.1) 4-L Natural 180x93x125 910
MC40-S S3.8G4 (India) PI144J 40 KVA 44 KVA NA - (7.6) 4-L Natural 180x93x121.5 765
MC50-S S3.8-G6 (India) UCI224D 50KVA 55 KVA NA - (9.5) 4-L Natural 180x93x121.5 815
MC60-S S3.8-G7 (India) UCI224E 60 KVA 66 KVA NA - (11) 4-L Natural 180x93x132 865
Genset Engine Alternator Rating @ 3x400V, Fuel #of Aspiration Dimensions Weight
Model Model 50Hz, 1500rpm Consumption cylinders (cm) (kg)
Prime Standby (L/h) Open Type
MV30 SUN 3105E2 28 kVA 31 kVA 4.2 3-L Natural 145x70x105 600
22 kW 25 kW
MV40 SUN 3105TE2 37 kVA 41 kVA 5.4 3-L Turbocharged 160x70x105 650
30 kW 33 kW
MV60 SUN 4105TE2 59 kVA 65 kVA 7.9 4-L Turbocharged 176x70x110 800
47 kW 52 kW
Powered by Perkins Meccalte
Powered by Cummins Stamford
Powered by VM
Generating Sets50 Hz - Range 3 - From 65 KVA to 100 KVA
Genset Engine Alternator Rating @ 3x400V, Fuel #of Aspiration Dimensions Weight
Model Model 50Hz, 1500rpm Consumption cylinders (cm) (kg)
Prime Standby g/kWh - (L/h) Open Type
MP65-S 1104A-44TG1 UC224F 65 KVA 72 KVA 209-(11.2) 4-L Turbocharged 211x106x138 1104
& A/A
MP80-S 1104A-44TG2 UC224G 80 KVA 88 KVA NA-(14) 4-L Turbocharged 211x106x138 1212
& A/A
MP95-S 1006TG1A UCI274C 93 KVA 102 KVA NA-(16.5) 6-L Turbocharged 252x110x164 1314
& A/A
MP100-S 1104C-44TAG2 UCI274C 100 KVA 110 KVA 207-(17.1) 4-L Turbocharged 211x106x139 1322
& A/A
Powered by Perkins Stamford
Genset Engine Alternator Rating @ 3x400V, Fuel #of Aspiration Dimensions Weight
Model Model 50Hz, 1500rpm Consumption cylinders (cm) (kg)
Prime Standby g/kWh - (L/h) Open Type
MP65-M 1104A- 44TG1 ECO32- 3L/4 65 KVA 71.5 KVA 209 - (11.2) 4-L Turbocharged 211x106x138 1065
MP80-M 1104A- 44TG2 ECP34- 1S 80 KVA 88 KVA NA - (14) 4-L Turbocharged 211x106x138 1170
MP95-M 1006TG1A ECP34- 2S 93 KVA 102.3 KVA NA - (16.5) 6-L Turbocharged 252x110x164 1327
MP100-M 1104C-44TAG2 ECP34- 2S 100 KVA 110 KVA 207 - (17.1) 4-L Turbocharged 211x106x139 1335
& A/A
Genset Engine Alternator Rating @ 3x400V, Fuel #of Aspiration Dimensions Weight
Model Model 50Hz, 1500rpm Consumption cylinders (cm) (kg)
Prime Standby g/kWh - (L/h) Open Type
MC100-S 6BTA5.9-G5 (India) UCI274C 100 KVA 110 KVA 221 - (18) 6-L Turbocharged 252x110x157.7 1337
Powered by Perkins Meccalte
Powered by Cummins Stamford
Generating Sets50 Hz - Range 4 - From 93 KVA to 150 KVA
Genset Engine Alternator Rating @ 3x400V, Fuel #of Aspiration Dimensions Weight
Model Model 50Hz, 1500rpm Consumption cylinders (cm) (kg)
Prime Standby g/kWh - (L/h) Open Type
MP105-S 1006TG2A UCI274C 102 KVA 110 KVA NA - (16.5) 6-L Turbocharged 252x110x164 1325
& A/A
MP140-S 1006TAG UCI274E 136 KVA 197.2 KVA NA - (24.1) 6-L Turbocharged 252x110x159 1409
& A/A
MP150-S 1006TAG2 UCI274F 150 KVA 165 KVA NA- (31) 6-L Turbocharged 252x110x159 1447
& A/A
Powered by Perkins Stamford
Genset Engine Alternator Rating @ 3x400V, Fuel #of Aspiration Dimensions Weight
Model Model 50Hz, 1500rpm Consumption cylinders (cm) (kg)
Prime Standby g/kWh - (L/h) Open Type
MP105-M 1006TG2A ECP34- 2S 102 KVA 112 KVA NA - (16.5) 6-L Turbocharged 252x110x164 1338
MP140-M 1006TAG ECP34- 2L 136 KVA 149.6 KVA NA - (24.1) 6-L Turbocharged 252x110x159 1408
& A/A
MP150-M 1006TAG2 ECP34- 2L 150 KVA 165 KVA NA - (31) 6-L Turbocharged 252x110x159 1408
& A/A
Genset Engine Alternator Rating @ 3x400V, Fuel #of Aspiration Dimensions Weight
Model Model 50Hz, 1500rpm Consumption cylinders (cm) (kg)
Prime Standby g/kWh - (L/h) Open Type
MC125-S 6BTAA5.9-G3 CI274E 125 KVA 137 KVA 213 - (24) 6-L Turbocharged 252x110x157.7 1423
(India)
Powered by Perkins Meccalte
Powered by Cummins Stamford
Generating Sets50 Hz -Range 5 - From 180 KVA to 250 KVA
Genset Engine Alternator Rating @ 3x400V, Fuel #of Aspiration Dimensions Weight
Model Model 50Hz, 1500rpm Consumption cylinders (cm) (kg)
Prime Standby g/kWh - (L/h) Open Type
MP180-S 1106C-E66TAG4 UCI274G 180 KVA 198 KVA 212.7- (31) 6-L Turbocharged 272x121x156.5 1762
& A/A
MP200-S 1306C- E87TAG3 UCI274H 200 KVA 220 KVA 213 - (35) 6-L Turbocharged 272x121x179.4 1691
& A/A
M230-S 1306C- E87TAG4 UCD274J 228 KVA 250.8 KVA 207 - (37.5) 6-L Turbocharged 272x121x179.4 1792
& A/A
MP250-S 1306C- E87TAG6 UCD274K 250 KVA 275 KVA 200 - (36) 6-L Turbocharged 272x121x179.4 1792
& A/A
Powered by Perkins Stamford
Genset Engine Alternator Rating @ 3x400V, Fuel #of Aspiration Dimensions Weight
Model Model 50Hz, 1500rpm Consumption cylinders (cm) (kg)
Prime Standby g/kWh - (L/h) Open Type
MP180-M 1106C-E66TAG4 ECO38- 1S 180 KVA 198 KVA 212.7 - (31) 6-L Turbocharged 272x121x156.5 1742
& A/A
MP200-M 1306C- E87TAG3 ECO38- 2S 200 KVA 220 KVA 213 - (35) 6-L Turbocharged 272x121x179.4 1625
& A/A
MP230-M 1306C- E87TAG4 ECO38- 3S/N 228 KVA 250 KVA 207 - (37.5) 6-L Turbocharged 272x121x179.4 1655
& A/A
MP250-M 1306C- E87TAG6 ECO38- 1L/N 250 KVA 275 KVA 200 - (36) 6-L Turbocharged 272x121x179.4 1745
& A/A
Powered by Perkins Meccalte
Genset Engine Alternator Rating @ 3x400V, Fuel #of Aspiration Dimensions Weight
Model Model 50Hz, 1500rpm Consumption cylinders (cm) (kg)
Prime Standby g/kWh - (L/h) Open Type
MC180-S 6CTA8.3-G2 (UK) UCI274G 182 KVA 200 KVA NA - (30) 6-L Turbocharged 272x121x165.3 2350
MC200Q-S QSB7-G5 (UK) UCI274H 200 KVA 220 KVA 223 - (36) 6-L Turbocharged 280x1133x161.5 1652
& A/A
MC200C-S 6CTAA8.3-G3 (UK) UCI274H 200 KVA 220 KVA 205 - (34) 6-L Turbocharged 280x133x166.5 1861
& A/A
MC250-S QSL9-G3 (UK) HCI444C 250 KVA 275 KVA 246 - (49) 6-L Turbocharged 280x133x188.8 2152
& A/w
Powered by Cummins Stamford
Generating Sets50 Hz -Range 6 - From 300 KVA to 500 KVA
Genset Engine Alternator Rating @ 3x400V, Fuel #of Aspiration Dimensions Weight
Model Model 50Hz, 1500rpm Consumption cylinders (cm) (kg)
Prime Standby g/kWh - (L/h) Open Type
MP300-S 1606A-E93TAG5 HC444D 330 KVA 300 KVA NA 6-L Turbocharged 360x141x181 2365
& A/A
MP350-S 2206A-E13TAG2 HC444E 350 KVA 385 KVA 198 - (54) 6-L Turbocharged 360x141x218.2 2964
& A/A
MP400-S 2206A-E13TAG3 HC444F 400 KVA 440 KVA 199 - (62) 6-L Turbocharged 360x141x218.7 3175
& A/A
MP450-S 2506A-E15TAG1 HC544C 455 KVA 500 KVA 200 - (72) 6-L Turbocharged 360x141x218 3433
& A/A
MP500-S 2506A-E15TAG2 HC544C 455 KVA 550 KVA 201 - (76) 6-L Turbocharged 360x141x218 3563
& A/A
Powered by Perkins Stamford
Genset Engine Alternator Rating @ 3x400V, Fuel #of Aspiration Dimensions Weight
Model Model 50Hz, 1500rpm Consumption cylinders (cm) (kg)
Prime Standby g/kWh - (L/h) Open Type
MP300-M 1606A-E93TAG5 ECO38- 2L/ N 300 kVA 330 kVA NA 6-L Turbocharged 360x141x181 2190
& A/A
MP350-M 2206A-E13TAG2 ECO38- 3L/ N 350 kVA 385 kVA 198 - (54) 6-L Turbocharged 360x141x218.2 2845
& A/A
MP400-M 2206A-E13TAG3 ECO40- 1S 400 kVA 440 kVA 199 - (62) 6-L Turbocharged 360x141x218.7 3055
& A/A
MP450-M 2506A-E15TAG1 ECO40- 2S 450 kVA 495 kVA 200 - (72) 6-L Turbocharged 360x141x218 3288
& A/A
MP500-M 2506A-E15TAG2 ECO40- 3S 500 kVA 550 kVA 201 - (76) 6-L Turbocharged 360x141x218 3998
& A/A
Powered by Perkins Meccalte
Genset Engine Alternator Rating @ 3x400V, Fuel #of Aspiration Dimensions Weight
Model Model 50Hz, 1500rpm Consumption cylinders (cm) (kg)
Prime Standby g/kWh - (L/h) Open Type
MC300-S QSL9-G5 (UK) HCI444D 300 KVA 330 KVA 194 - (46) 6-L Turbocharged 280x133x188.8 2252
& A/A
MC320-S NT855-G6 (India) HCI444E 320 KVA 352 KVA 210 - (52) 6-L Turbocharged 360x141x198.5 2971
MC365-S NTA855-G4 (India) HCI444F 365 KVA 402 KVA 204 - (57) 6-L Turbocharged 360x141x198.5 3107
& A/W
MC500-S QSX15-G8 (USA) HCI544C 500 KVA 550 KVA 201 - (78.7) 6-L Turbocharged 360x141x190 3785
& A/A
Powered by Cummins Stamford
Generating Sets50 Hz - Range 7 - From 600 KVA to 2000 KVA
Genset Engine Alternator Rating @ 3x400V, Fuel #of Aspiration Dimensions Weight
Model Model 50Hz, 1500rpm Consumption cylinders (cm) (kg)
Prime Standby g/kWh - (L/h) Open Type
MP600-S 2806A-E18TAG1A HC544E 600 KVA 660 KVA 199 - (90) 6-L Turbocharged 331x155x209.8 4787
& A/A
MP650-S 2806A-E18TAG2 HC544F 650 KVA 715 KVA 198 - (97) 6-L Turbocharged 331x155x224.6 4900
& A/A
MP750-S 4006- 23TAG2A HCI634G 750 KVA 825 KVA 211 - (121) 6-L Turbocharged 385x132x227.2 6000
& A/A
MP800-S 4006- 23TAG3A HCI634G 800 KVA 880 KVA 210 - (130) 6-L Turbocharged 385x172x227.2 6370
& A/A
MP1000-S 4008TAG2A HCI634J 1022 KVA 1124 KVA 202 - (160) 8-L Turbocharged 480x207x223.5 7600
& A/A
Powered by Perkins Stamford
Genset Engine Alternator Rating @ 3x400V, Fuel #of Aspiration Dimensions Weight
Model Model 50Hz, 1500rpm Consumption cylinders (cm) (kg)
Prime Standby g/kWh - (L/h) Open Type
MP1250-S 4012- 46TWG2A PI734A 1250 KVA 1375 KVA 216 - (196) 12-L Turbocharged 478x178x242.4 9255
& & A/W
MP1500-S 4012- 46TAG2A PI734C 1505 KVA 1655 KVA 201 - (237) 12-L Turbocharged 520x210x243.5 9910
& A/A
MP1850-S 4016TAG1A PI734E 1845 KVA 2029.5 KVA 198 - (277) 16-L Turbocharged 600x274x302 15416
& A/A
MP2000-S 4016TAG2A PI734F 2058 KVA 2263.8 KVA 203 - (316) 16-L Turbocharged 600x274x302 15700
& A/A
MP2000U-S 4016- 61TRG2*** PI734F 2000 KVA 2200 KVA 206 - (337) 16-L Turbocharged 600x274x302 15700
& A/W
MP2000T-S 4016- 61TRG2*** PI734F 2000 KVA 2200 KVA 206 - (337) 16-L Turbocharged 600x274x302 15700
& A/W
MP2200-S 4016- 61TRG3*** PI734G 2200 KVA 2420 KVA 200 - (346) 16-L Turbocharged 600x274x302 15914
& A/W
Powered by Perkins Stamford
Genset Engine Alternator Rating @ 3x400V, Fuel #of Aspiration Dimensions Weight
Model Model 50Hz, 1500rpm Consumption cylinders (cm) (kg)
Prime Standby g/kWh - (L/h) Open Type
MC635-S VTA25-G5(2) HCI544F 636 KVA 700 KVA 211 - (104) 12-V Turbocharged 331x55x253.5 6140
(India) & A/A
MC800-S QSK23-G3(3) HCI634G 810 KVA 891 KVA 196 - (121) 6-L Turbocharged 385x172x235 6238
(Japan) & A/A
MC1000-S QST30-G4 HCI634J 1000 KVA 1100 KVA 194 - (151) 12-V Turbocharged 480x207x235 7264
(USA) & A/W
MC1260-S KTA50-G3 PI734A 1260 KVA 1385 KVA 206 - (199) 16-L Turbocharged 478x178x237 9637
(India) & A/W
MC1275-S KTA50-G3 PI734B 1275 KVA 1400 KVA 206 - (199) 16-L Turboharged 478x178x237 9637
(India) & A/W
MC1400-S KTA50-G8 PI734B 1400 KVA 1540 KVA 210 - (222) 16-L Turbocharged 520x210x287.8 10713
(Japan) & A/W
MC2000-S QSK60-G4 PI734F 2045 KVA 2250 KVA 191 - (291) 16-V Turbocharged 600x274x353 16815
(UK) & A/W
Powered by Cummins Stamford
New ProductIntroduction (NPIs)
Ranger
Ranger 24/40 1001 series
A unique Solution, especially de-signed to withstand rough weather and road conditions that will run for 1000 hours or 40 days before the any service.
EnerSaver
HTA 1000
An AC/DC Hybrid Solution for Telecom Applications which enables you to pay your Capex through the savings on your Opex.
SandStormer VX1
A reliable Solution, equipped with
designed to withstand rain and sand storms.
Ranger 24/40 1001 series
SandStormerEnerSaver
Standard Generating Set Features:• Water cooled diesel coupled to
single bearing alternator.• • Standard voltage 230/400 at 50 Hz.• Three poles circuit breaker
(MCCB).• Auto Start Module of type
DSE6010 (M-DCM-317B).• Steel base frame with anti-
vibration pads.• Fuel level reading and protection.Each Genset is factory load tested and quality controlled.
Engine Speci�cations:• Vertical inline indirect injection.• Water cooled, four strokes,
turbocharged.• 12V cranking battery voltage.• Mechanically governed fuel
injection pump.• Thermostat controlled
cooling system with gear-driven water pump.
Alternator Speci�cations:• Brushless single bearing 4
poles.• Class H insulation.• IP21 (higher protection level
on request).• 5% voltage variation
(locally or remotely), under speed protection, stability adjustment.
• 2/3 pitch winding system to
• Alternator is 12 lead reconnectable.• Comply with the norms: CEE/CE12-
3/EN60034-1/IEC34-1/VDE/BS/CAN/CSA.
• Oil Management system allowing long run operation of up to 1000 hrs continuously.
• Sy-Klone Air Precleaner installed at air intake system.
• Chrome, Red painted canopy design for heavy duty purposes.• Sandstormer canopy design for sand traping ability.• Skid mounted fuel tank (524L) for 24hrs operation at full load.•
and automotive lighting.
Engine• Manual Sump Drain Pump (DP)• Semi Rotator Hand Oil Pump (DRP)• Water Level Protection (WLP)• Jacket Heater (EJH-20P)Fuel Options• Fuel Water Seperator (Separ 2000/5)Alternator• Anti Condensation Heater (ACH)
Additional Key Features: Generating Set Options
Open Set:Length (mm): 3789 mmwidth (mm): 1090 mmHeight (mm): 1600 mm
Enclosed-Trailer S TypeLength (mm): 4520 mmwidth (mm): 2110 mmHeight (mm): 2450 mm
Electrical System• Battery Charger 12V, 5A (BC12)• Genset Alarm Relay (GAR12)• 4-Pole Circuit Breaker (4P)• DSE Genset Controller (DSE-XXXX)Enclosed Unit• Sound Proof Enclosure (SM Type)Voltage Connections• 230/400V• 115/200V
Max Dimensions
24/40 1001 series
An Enclosed SandStormer set with a prime 103 KVA Perkins engine coupled with Meccalte alternator, equipped with a long run engine kit and mounted on
A unique Solution, especially designed to withstand rough weather and road conditions that will run for 1000 hours
service.
A solution that will save you both time and money while operating in rainy or sandy storms.
Ranger
Ran
ger
24/4
0
100
1 ser
ies
An AC/DC Hybrid
Solution for Telecom
Applications which
enables you to pay
your Capex through the
savings on your Opex.
Adopt a solution that will enable
• More than 60% fuel
savings
• Lower frequency of site
visits
• Decreased
maintenance costs
• Increased site
availability
• Less replacement costs
• Master control of
system management
and remote monitoring
Allied International o�ers you Enersaver
An economic, maintenance free, eco-friendly solution implementing robust batteries powered by a combination of diesel generators, unreliable grid and renewable solar/wind energy.
the system.Allied International EnerSaver adapts to your existing system. Standard genset can be upgraded into a hybrid system adding up to your existing components to achieve maximum return on investment (ROI) in less than 2 years.
Allied International is delighted to suggest its EnerSaver Hybrid Power station in order to supply your BTS sites. An economic, maintenance free, eco-friendly solution implementing robust batteries powered by a combination of diesel generators, unreliable grid and a renewable solar/wind energy. Allied International EnerSaver adapts to your existing system. Standard genset can be upgraded into a hybrid system adding up to your existing components to achieve maximum return on investment (ROI) in less than 2 years depending on your Site load demand. Based on this arrangement you will get a dramatically reduced OPEX by minimizing the engine daily run to as economical as 65% minimum fuel reduction and reduced site Visits .
EnerSaverHTA 1000
Software Calculation Tools
Allied International comprehensive array of modeling and dimensioning tools allows the optimum Hybrid solution to be accurately specified based on power consumption, geographic location, financial and O&M data to suit a given CapEx/ OpEx/ ROI requirement.A complete financial analysis can be done to compare a typical site (ex. two generating sets, generator and batteries) with the new hybrid solution.
The Perfect Solution For Dusty Application
Sand
Stor
mer
VX1
• Designed to operate in
dusty desert conditions,
due to sand traps and
and gravity dampers on
the outlet side
• Compact & maintenance
friendly sound proof enclosure
• All canopy openings
(Diesel connections, cable
entry…) are carefully
designed to protect the
genset against sand and
splashing water
SandStormer
VX1
The new ALLIED
SANDSTORMER is
to withstand sand and
water reaching a high
protection level of IP 53
6 Reasons
to choose
GENMET
1• Easier Maintenance
2• No Electronics
3•Tropical Radiators for higher ambient temperature
4• Lower Fuel Consumption
5• Extended warranty
6• Lower TCO (Total Cost of Ownership)
GENMET SERIES50 Hz - Ranges - From 5 KVA to 700 KVA
Genset Engine Alternator Rating @ 3x400V, Fuel #of Aspiration Dimensions Weight
Model Model 50Hz, 1500rpm Consumption cylinders (cm) (kg)
Prime Standby g/kWh - (L/h) Open Type
GL7-LP LPW2 LPA712 8 KVA 8.8 KVA 214 (1.9) 2-L Natural 145*76*106.2 431
GL12-LP LPW3 LPA815 12.2 KVA 13.4 KVA 209.3 (2.8) 3-L Natural 145*76*110 461
GL16-LP KPW4 LPA1118 16.3 KVA 18 KVA 214 (3.8) 4-L Natural 145*76*110 513
GL20-LP LPWX4 LPA1524 20 KVA 22 KVA 224.4 (4.7) 4-L Natural 145*76*110 545
GA40-E ALGPW4DMK1EE GE188-40D 40 KVA 44 KVA 5.6 4-L Natural 211*106*126.5 826
GA60-E AL4DTG3E GE228-60B 60 KVA 66 KVA 9 4-L Turbocharged 211*106*135.5 942
GA80-E AL4DTIG2E GE228-80E 80 KVA 88 KVA 13 4-L Turbocharged 211*106*152.5 980
GA100-E AL6DTIG1E GE228-100G 100 KVA 110 KVA 16.5 6-L Turbocharged 252*121*145.5 1278
&Intercooled
Genmet Set
Genset Engine Alternator Rating @ 3x400V, Fuel #of Aspiration Dimensions Weight
Model Model 50Hz, 1500rpm Consumption cylinders (cm) (kg)
Prime Standby g/kWh - (L/h) Open Type
GM125-W 7.2P-125 GTA251ZEHD 125 KVA 137.5 KVA 202 (27.13) 6-L TCA 272*120*173 1460
GM160-W 7.2P-160 GTA251ZEHE 160 KVA 176 KVA 197 (34.15) 6-L TCA 272*120*173 1480
GM180-W 7.2P-180 GTA251ZIHE 180 KVA 198 KVA 202.5 (38.5) 6-L TCA 272*120*173 1480
GM200-W 7.2P-200 GTA252ZIVB 200 KVA 220 KVA 202.5 (42) 6-L TCA 272*120*173 1662
GD200-W P086T1 GTA252ZIVB 191 KVA 210 KVA 203 (43.1) 6-L TCA 274*940*155 1810
GD275-W P126T1 GTA252ZIIR 273 KVA 300 KVA 201 (58.1) 6-L TCA 280*105*155.6 2025
GD300-W P126T1-II GTA252ZIVS 291 KVA 320 KVA 201 (63.1) 6-L TCA 300*105*155.6 2300
GD400-W P158LE GTA311ZIIH 401.6 KVA 442 KVA 215 (89.3) 8-V TCA 300*124*184.3 2720
GD500-W P180LE GTA312ZIIB 507.8 KVA 559 KVA 209 (111.6) 10-V TCA 320*124*184.3 3040
GD625-W P222LE GTA312ZIDI 612 KVA 673 KVA 209 (134) 12-V TCA 350*140*184.31 3685
Genmet Set
After Sales Services
On top of the product portfolio comes The Service Excellence Allied International could be providing for its partners either directly by itself as an additional knowledge and expertise sharing making sure our partners are selecting their right and correct optimized needed solution to suit their requirements and related application pointing to: • Space restriction; • Electrical load needs (actual load and
potential future expansions…)
• CAPEX optimization;
• OPEX reduction (fuel consumption…)
or indirectly through our specialized teams
in Allied Octopus -- sales, after sales,
service and maintenance support network
known by POWERMET who would be providing
a guided preventive and corrective maintenance
services respecting LSA agreements while
ensuring:
• Financial facilities ;
• Spare parts availability;
Customer Service
Ten Commandments of customer service
• We Simply love you , our customers
• We consider your business as it’s ours
• We under-promise and over-deliver
• We strive for Regular feedback
• We know how to apologize
• We make customers understand our systems
• When we don’t hear your complaint, we suspect something is wrong
• We are compassionate
• We are courteous
WORDS WE LIVE BY
“ WE CARE. YOU TRUST. WE DELIVER”
Cummins P owered
MC -6 /35S
MC -6 /45S
MC -6 /55S
MC -6 /125S
MC -6 /200S
MC -6 /225S
MC -6 /230S
MC -6 /285S
MC -6 /345S
MC -6 /325S
MC -6 /450S
MC -6 /560S
MC -6 /680S
MC -6 /910S
MC -6 /1140S
MC -6 /1400S
MC -6 /1600S
S-3.8G8 (India)
S-3.8G9 (India)
S-3.8G10 (India)
6BTA-5.9G6 (India)
6C TA-8.3G2 (UK)
QSB -7G5 (UK)
6C TAA-8.3G1)3) (UK)
QSL -9G3 (UK)
QSL -9G5 (UK)
NT -855G6 (India)
QSX -15G8 (USA)
QSX -15G9 (USA)
VTA-28G2)5) (India)
QSK -23G3)3) (Japan)
QST -30G4 (USA)
KTA-50G3 (India)
KTA-50G9 (India)
NA - (8.5 )
NA - (10.5 )
NA - (12.5 )
22) - 219 )
35) - 211 )
NA - (40)
41) - 211)
58) - 248)
55) - 201)
56) - 215)
75.2) - 206)
90.5) - 202)
118) - 220 )
139) - 195 )
177) - 199 )
222) - 207 )
257) - 211 )
-4L
-4L
-4L
-4L
-6L
-6L
-6L
-6L
-6L
-6L
-6L
-6L
-12V
-6L
-12V
-16V
-16V
815
865
1168
1312
1558
1652
1861
2152
2252
2887
3655
4286
6140
6238
7264
10400
10970
180x93x125
180x93x132
211x106x143.8
252x110x257.5
272x121x165.3
280x133x161.5
280x133x166.5
280x133x188.8
280x133x188.8
360x141x198.5
360x141x290
331x155x205.9
331x155x253.5
385x172x235
480x207x235
520x225x223.3
520x225x225
Genset EngineModel
Fuel Consumption*
g/kWh - (L/h)
# of Cylinders
We ight(Kg)
Dimensions(cm)
Open Type
* Fuel Consumption figures above are given @ %75 Prime Load.
Standard Equipment
Diesel Engine: 4 stroke, direct & indirect injection, water cooled, suitable for high ambient temperature.
Alternator: Synchronous, 4 poles alternating current, three phase, horizontal axle, self/seperately excited, brushless, self ventilated, designed in compliance withIEC 1 -34, CEI 3 -2, VDE 0530, BS 5000- 4999, NF 100 -51, electronic voltage regulator .
Coupling: The alternator and engine are directly coupled by means of SAE flange adaptor so that there is no possibility of misalignment af ter prolonged use. The engine flywheel is flexibly coupled to the alternator rotor and a full torsional analysis has been carried out to ensure no harmful vibration will occur in the assembly.
Base frame: The complete generator set is mounted, as a whole, on a heavy duty fabricated, welded steel base frame. The base frame incorpo rates a daily fuel tank, with digital fuel level reading and shut down protection.
Anti- Vibration pads: Anti-vibration pads are affixed between engine and alternator feet and the base frame thus ensuring complete vibration isolation of the rotating assemblies and enabling the machine to be placed on an even surface without any detrimental e�ects.
Due to continuous product development, we reserve the right to change specifications at any time without prior notice.
PI144 H
UCI224 D
UCI224 D
UCI224 E
UCI224 G
UCI274 H
UCI274 H
HCI444 C
HCI444 D
HCI444 D
HCI544 C
HCI544 E
HCI544 F
HCI634 G
HCI634 J
PI734 A
PI734 C
AlternatorModel
Turbocharged
Aspiration
Turbocharged& A/A
Turbocharged& A/A
Turbocharged& A/A
Turbocharged& A/W
Turbocharged& A/W
Turbocharged& A/W
Turbocharged
Turbocharged
Turbocharged& A/A
60Hz, 1800 rpmDiesel Engine:
Alternator:CEI 3 -2, VDE 0530, BS 5000 -4999, NF 100- 51, electronic voltage regulator
Coupling:engine flywheel is flexibly coupled to the alternator rotor and a full torsional analysis has been carried out to ensure no harmf
Base frame:tank, with digital fuel level reading and shut down protection.
Anti-rotating assemblies and enabling the machine to be placed on an even surface without any detrimental e�ects.
Due to continuous product development, we reserve the right to change specifications at any time without prior notice.
35 kV A
45 kV A
54 kV A
125 kV A
200 kV A
225 kV A
228 kV A
285 kV A
344 kV A
325 kV A
450 kV A
563 kV A
680 kV A
909 kV A
1138 kV A
1418 kV A
1619 kV A
38.5 kV A
49.5 kV A
54.9 kV A
137 kV A
220 kV A
248 kV A
251 kV A
314 kV A
378 kV A
358 kV A
495 kV A
619 kV A
748 kV A
1000 kV A
1252 kV A
1400 kV A
1781 kV A
35 kV A
45 kV A
54 kV A
125 kV A
200 kV A
225 kV A
228 kV A
285 kV A
344 kV A
325 kV A
450 kV A
563 kV A
670 kV A
875 kV A
1138 kV A
1375 kV A
1619 kV A
38.5 kV A
49.5 kV A
49.5 kV A
137 kV A
220 kV A
248 kV A
251 kV A
314 kV A
378 kV A
358 kV A
495 kV A
619 kV A
670 kV A
963 kV A
1252kV A
1513 kV A
1781 kV A
Prime Standby
Rating @3 x 480 V,
Prime Standby
Rating @3 x 416 V,
Turbocharged& A/A
Turbocharged
Turbocharged& A/W
Turbocharged& A/A
Turbocharged& A/A
Turbocharged& A/W
Turbocharged& A/A
MP-6 /11M
MP-6 /16M
MP-6 /18M
MP-6 /25M
MP-6 /35M
MP-6 /48M
MP-6 /53M
MP-6 /70M
MP-6 /75M
MP-6 /90M
MP-6 /110M
MP-6 /113M
MP-6 /120M
MP-6 /150M
MP-6 /205M
MP-6 /230M
MP-6 /245M
MP-6 /345M
MP-6 /400M
MP-6 /500M
MP-6
MP-6
MP-6
MP-6
MP-6
MP-6
MP-6
MP-6
Genset
Lister P owered
ML-6 /8 M
ML-6 /9 M
ML-6 /14M
ML-6 /19M
ML-6 /25M
LPW2
LPW2
LPW3
LPW4
LPWX4
NA - (1.8 )
NA - (1.8 )
NA - (2.7 )
3.6) - 219 )
4.6) - 211 )
-2L
-2L
-3L
-4L
-4L
405
411
453
513
519
145x76x106.2
145x76x106.2
145x76x110
145x76x110
145x76x110
Genset EngineModel
Fuel Consumption*
g/kWh - (L/h)
# of Cylinders
We ight(Kg)
Dimensions(cm)
Open Type
ECP1 -3SN/ 4
ECP25 -3N/ 4
ECP2 -3LN/ 4
ECO-28 SN/ 4
ECO1 -28LN/ 4
AlternatorModel
Aspiration60Hz, 1800 rpm
7.8 kV A
9.3 kV A
13.7 kV A
19 kV A
24 kV A
8.6 kV A
10.2 kV A
15 kV A
20.9 kV A
26.4 kV A
6.8 kV A
8.5 kV A
13.7 kV A
17.25 kV A
20.5 kV A
7.4 kV A
9.3 kV A
15 kV A
139 kV A
22.6 kV A
Prime Standby
Rating @3 x 480 V,
Prime Standby
Rating @3 x 400 V,
Natural
Natural
Natural
Natural
Turbocharged
* Fuel Consumption figures above are given @ %75 Prime Load.
Genset
Diesel Engine: 4 stroke, direct injection, water cooled, suitable for high ambient temperature.
Alternator: Synchronous, 4 poles alternating current, three phase, horizontal axle, self excited, brushless, self ventilated, designed in compliance with IEC 1- 34 ,CEI 3 -2, VDE 0530, BS 5000 -4999, NF 100- 51, electronic voltage regulator .
Coupling: The alternator and engine are directly coupled by means of SAE flange adaptor so that there is no possibility of misalignment after prolonged use. The engine flywheel is flexibly coupled to the alternator rotor and a full torsional analysis has been carried out to ensure no harmful vibration will occur in the assembly.
Base frame: The complete generator set is mounted, as a whole, on a heavy duty fabricated, welded steel base frame. The base frame incorpo rates a daily fuel tank, with digital fuel level reading and shut down protection.
Anti- Vibration pads: Anti-vibration pads are affixed between engine and alternator feet and the base frame thus ensuring complete vibration isolation of the rotating assemblies and enabling the machine to be placed on an even surface without any detrimental e�ects.
Due to continuous product development, we reserve the right to change specifications at any time without prior notice.
Standard Equipment
Perkins Po wered
Natural
Natural
Natural
Natural
Natural
MP-6 /11M
MP-6 /16M
MP-6 /18M
MP-6 /25M
MP-6 /35M
MP-6 /48M
MP-6 /53M
MP-6 /70M
MP-6 /75M
MP-6 /90M
MP-6 /110M
MP-6 /113M
MP-6 /120M
MP-6 /150M
MP-6 /205M
MP-6 /230M
MP-6 /245M
MP-6 /345M
MP-6 /400M
MP-6 /500M
MP-6 /11S
MP-6 /16S
MP-6 /25S
MP-6 /34S
MP-6 /35S
MP-6 /50S
MP-6 /55S
MP-6 /70S
403D 11-G
403A 15-G
403A 15-G 2
404D 22-G
1103 A33-G
1103 A- 33TG1
1103 A- 33TG1
1103 A- 33TG2
1104 A- 44TG1
1104 A- 44TG2
1006TG1A
1104 C- 44 TAG2
1006TG2A
1006 TAG
1106C -E66T AG 4
1306 C- E87T AG 3
1306 C- E87T AG 4
1606 A-E93TAG 4
2206 A-E13TAG 2
2506 A-E15TAG 1
403D - 11 G
403D - 15 G
404D - 22 G
1103 A- 33G
1103 A- 33G
1103 A- 33TG1
1103 A- 33TG1
1103 A- 33TG2
11.3 kV A
16 kV A
18 kV A
24 kV A
35 kV A
48 kV A
53 kV A
68 kV A
76 kV A
91 kV A
110 kV A
113 kV A
120 kV A
151 kV A
206 kV A
230 kV A
245 kV A
344 kV A
400 kV A
500 kV A
11 kV A
15.6 kV A
24.2 kV A
34 kV A
35 kV A
50 kV A
53 kV A
68 kV A
12.43 kV A
17.6 kV A
19.8 kV A
26.4 kV A
38.5 kV A
52.8 kV A
58.3 kV A
74.8 kV A
83.6 kV A
100 kV A
121 kV A
124 kV A
112 kV A
166 kV A
227 kV A
253 kV A
250 kV A
300 kV A
440 kV A
550 kV A
12.1 kV A
17.16 kV A
26.6 kV A
37 kV A
39 kV A
55 kV A
46.5 kV A
75 kV A
-3 L
-3 L
-3 L
-4 L
-3 L
-3 L
-3 L
-3 L
-4 L
-4 L
-6 L
-4 L
-6 L
-6 L
-6 L
-6 L
-6 L
-6 L
-6 L
-6 L
-3 L
-3 L
-4 L
-3 L
-3 L
-3 L
-3 L
-3 L
2.4) - 257 )
3.3) - 249 )
NA
4.8) - 247 )
NA - (6.6 )
NA - (9.9 )
NA - (9.9 )
NA - (12.5)
13.5 ) - 214)
NA - (16.9)
NA - (19.9)
20.2 ) -218 )
NA - (19.9)
NA - (28.9)
NA - (36.8)
38.5 ) - 211)
40.3 ) - 208)
NA
62) - 199)
78) - 206)
2.4) - 257 )
3.3) - 249 )
4.8) - 247 )
NA - (6.6 )
NA - (6.6 )
NA - (9.9 )
NA - (9.9)
NA - (12.5)
42 2
50 0
54 9
57 5
82 7
88 4
91 8
95 2
1065
1170
1327
1335
1338
1408
1742
1625
1655
2190
2845
3288
42 0
49 8
572. 5
81 1
82 2
80 9
81 8
98 1
145x76x111.5
145x76x120.6
145x76x120.8
145x76x125.5
180x93x126
180x93x126
180x93x126
180x93x126
211x106x13 8
211x106x13 8
252x110x16 4
211x106x139
252x110x164
252x110x159
272x121x156. 5
272x121x179. 4
272x121x179. 4
360x141x18 1
360x141x218. 2
3360x141x218
145x76x111.5
145x76x120.6
145x76x125.5
180x93x126
180x93x126
180x93x126
180x93x126
180x93x126
ECP1 -3L/ 4
ECP2 -3L/ 4
ECP3 -3L/ 4
ECO1 -28L/ 4
ECP-28 VL/ 4
ECO3 -32S/ 4
ECO1 -32L/ 4
ECO2 -32L/ 4
ECO3 -32L/ 4
ECP1 -34S
ECP2 -34S
ECP2 -34S
ECP2 -34S
ECP2 -34L
ECO1 -38S
ECO2 -38S
ECO3 -38S/ N
ECO2 -38L/ N
ECO3 -38L/ N
ECO2 -40S
PI044E
PI044F
PI144D
PI144F
PI144G
PI144J
PI144K
UC224E
Turbocharged
Turbocharged
Turbocharged
Turbocharged &A/A
Turbocharged
Turbocharged &A/A
Turbocharged &A/A
Turbocharged &A/A
Turbocharged &A/A
Turbocharged &A/A
Turbocharged &A/A
Turbocharged &A/A
Genset EngineModel
Fuel Consumption*
g/kWh - (L/h)
# of Cylinders
We ight(Kg)
Dimensions(cm)
Open Type
AlternatorModel
Aspiration60Hz, 1800 rpm
Prime Standby
Rating @3 x 480 V,
Prime Standby
Rating @3 x 400 V,
11.3 kV A
13.75 kV A
15.5 kV A
20.5 kV A
31.5 kV A
44 kV A
53 kV A
60 kV A
72.5 kV A
91 kV A
109 kV A
113 kV A
113 kV A
150 kV A
195 kV A
218 kV A
245 kV A
313 kV A
365 kV A
470 kV A
11 kV A
13.8 kV A
22 kV A
30 kV A
33 kV A
44 kV A
50 kV A
68 kV A
12.43 kV A
15.13 kV A
17 kV A
22.55 kV A
32.5 kV A
48.4 kV A
58.3 kV A
66 kV A
79.8 kV A
100 kV A
120 kV A
124 kV A
124 kV A
165 kV A
215 kV A
228 kV A
250 kV A
328 kV A
403 kV A
517 kV A
12.1 kV A
14.9 kV A
24.2 kV A
33 kV A
36 kV A
48 kV A
55 kV A
74 kV A
Turbocharged
Turbocharged
Turbocharged
Natural
Natural
Natural
Natural
Natural
Turbocharged &A/A
Turbocharged &A/A
Turbocharged &A/A
Genset EngineModel
Fuel Consumption*
g/kWh - (L/h)
# of Cylinders
We ight(Kg)
Dimensions(cm)
Open Type
AlternatorModel
Aspiration60Hz, 1800 rpm
Prime Standby
Rating @3 x 480 V,
Prime Standby
Rating @3 x 416 V,
Rating Sheet 5 to 2500 kV ARating Sheet 5 to 2500 kV A - 50 Hz
Riad El Solh Square, Banks Street, Arab Bank BuildingBeirut Central District - Lebanon
T. +961 1 973 919 +961 1 973 917 - M. +961 3 112 824
[email protected] www.aigtcc.com
Rating Sheet 5 to 2500 kV ARating Sheet 5 to 2500 kV A - 60 Hz
A L L I E DINTERNATIONAL
Perkins Powered / Stamford
* Fuel Consumption figures above are given @ 75% P rime Load.
Perkins Po wered / Meccalte
Lister Po wered / Meccalte
Cummins Po wered / Stamfor d
Riad El Solh Square, Banks Street, Arab Bank BuildingBeirut Central District - Lebanon
T. +961 1 973 919 +961 1 973 917 - M. +961 3 112 824
[email protected] www.aigtcc.com