3
QUICK PROGRAMING GUIDE page1 Connect the battery and power up the system select: SECURITY, MENU, TOOLBOX, RIGHT ARROW, INSTALLER TOOLBOX enter: 1561 select: Here is where you will be programing your different zones, or modifying the field programing. (see your Instalation/Programing Guide) System Configuration Q.1 ZONE PROGRAMING Scroll between options using or Move to previous or next prompt by selecting or Q.1 RF SENSOR PROGRAMING (1 thru 48) select: Sensor (zone) Type (see p.2) select: Equipment Code (see p.2) enter: Serial Number Enter the serial number manually or Learn in the sensor by selecting: Shift, Learn, then trip the sensor select: Equipment Age (New/Existing) select: Sensor Loop Number Loop 1-Motions, Glassbreaks, Smoke, Recessed D/W, Panic Pendant, D/W with wire lead Loop 2-D/W using internal switch Loop 3-Flood and Freeze Sensors select: Dialer Delay (Enabled/Disabled) select: Voice Descriptor (see p.2) Insert to add a word, then type the 3 digit code Repeat for additional words and to move between words select: Sensor Reports (Enabled/Disabled) select: Sensor Supervised (Enabled/Disabled) select: Sensor Chine 0-Disabled 1-Voice Only 2-Voice with Ding-Dong 3-Loud Ding-Dong 4-Loud Ding-Dong with Voice 5-Ding-Dong SUMMARY SCREEN Look over sensor information to make sure all settings are satisfactory. Edit Next to add the next sensor Skip to move to Wired Sensor programing Skip (again) to move to Keyfob programing Q.2 WIRED SENSOR PROGRAMING (1-2) select: Sensor (Zone) Type (see p.2) select: Equipment Code (see p.2) select: Equipment Age (New/Existing) select: Normal State 0-Not Used 1-Normaly Closed 3-Normaly Open 4-Mixed with no EOL select: Dialer Delay (Enabled/Disabled) select: Voice Descriptor (same as RF sensor programing. See p.2) select: Sensor Reports (Enabled/Disabled) select: Sensor Chimes (same as RF sensor programing) SUMMARY SCREEN Look over sensor information to make sure all settings are satisfactory. Edit Next to add the next sensor Skip to move to Wired Sensor programing Skip (again) to move to Keyfob programing ///////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////// ///////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////// /////////////////////////////////////////////////////////////////////////// /////////////////////////////////////////////////////////////////////////// /////////////////////////////////////////////////////////////////////////// /////////////////////////////////////////////////////////////////////////// Q.3 KEYFOB PROGRAMING Q.3 FOB # (1 thru 8) select: Fob Used (Used/Unused) select: Equipment Code (see p.2) enter: Serial Number (Same as RF Programing) select: Equipment Age (New/Existing) select: Emergency Key 0-Disabled 1-Auxilary 2-Audible 3-Silent Panic 4-Fire select: Fob Can Disarm (Enabled/Disabled) select: Voice Descriptor (Same as RF Programing. See p.2) select: Fob Arm with No Delay (Enabled/Disabled) select: Fob Output 0-Disabled 1-Toggle Output 2-Momentary Output SUMMARY SCREEN Look over sensor information to make sure all settings are satisfactory. Edit Next to add the next sensor Skip to move to Wired Sensor programing Skip (again) to move to Keyfob programing Q.4 KEYPAD PROGRAMING Q.4 KEYPAD # (1 thru 4) select: Keypad Used (Used/Unused) select: Equipment Code (see p.2) enter: Serial Number (Same as RF Programing) select: Equipment Age (New/Existing) select: Emergency Key (Enabled/Disabled) select: Voice Descriptor (Same as RF Programing. See p.2) SUMMARY SCREEN Look over sensor information to make sure all settings are satisfactory. Edit Next to add the next sensor Skip to move to Wired Sensor programing Skip (again) to move to Keyfob programing FIELD PROGRAMING Change the Questions below accordingly: CELL PRIMARY 2-WAY or DIGITAL Go To: 13- enter 1 (2-way) enter 0 (digital) Go To: 08-Disable Go To: 63-Disable CELL BACKUP Go To: 08-Enable Go To: 63-Enable Go To: 11-Enter Receiver Line# Go To: 12-Enter CSID#

QUICK PROGRAMING GUIDE - Security Pro of Florida LLC · QUICK PROGRAMING GUIDE page1 Connect the ... Go To: 12-Enter CSID# ... 162 one hundred 163 output 164 outside 165 PANEL

Embed Size (px)

Citation preview

QUICK PROGRAMING GUIDE page1

Connect the battery and power up the system

select: SECURITY, MENU, TOOLBOX, RIGHT ARROW, INSTALLER TOOLBOXenter: 1561select:Here is where you will be programing your different zones,or modifying the field programing. (see your Instalation/Programing Guide)

System Configuration

Q.1 ZONE PROGRAMING Scroll between options using or Move to previous or next prompt by selecting or

Q.1 RF SENSOR PROGRAMING (1 thru 48)select: Sensor (zone) Type (see p.2)

select: Equipment Code (see p.2)

enter: Serial Number Enter the serial number manually or Learn in the sensor by selecting: Shift, Learn, then trip the sensor

select: Equipment Age (New/Existing)

select: Sensor Loop Number Loop 1-Motions, Glassbreaks, Smoke, Recessed D/W, Panic Pendant, D/W with wire lead Loop 2-D/W using internal switch Loop 3-Flood and Freeze Sensors

select: Dialer Delay (Enabled/Disabled)

select: Voice Descriptor (see p.2) Insert to add a word, then type the 3 digit code Repeat for additional words and to move between words

select: Sensor Reports (Enabled/Disabled)

select: Sensor Supervised (Enabled/Disabled)

select: Sensor Chine 0-Disabled 1-Voice Only 2-Voice with Ding-Dong 3-Loud Ding-Dong 4-Loud Ding-Dong with Voice 5-Ding-Dong

SUMMARY SCREENLook over sensor information to make sure all settings are satisfactory.Edit Next to add the next sensorSkip to move to Wired Sensor programingSkip (again) to move to Keyfob programing

Q.2 WIRED SENSOR PROGRAMING (1-2)select: Sensor (Zone) Type (see p.2) select: Equipment Code (see p.2)

select: Equipment Age (New/Existing)

select: Normal State 0-Not Used 1-Normaly Closed 3-Normaly Open 4-Mixed with no EOL

select: Dialer Delay (Enabled/Disabled)

select: Voice Descriptor (same as RF sensor programing. See p.2)

select: Sensor Reports (Enabled/Disabled)

select: Sensor Chimes (same as RF sensor programing)

SUMMARY SCREENLook over sensor information to make sure all settings are satisfactory.Edit Next to add the next sensorSkip to move to Wired Sensor programingSkip (again) to move to Keyfob programing

/////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////

/////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////

///////////////////////////////////////////////////////////////////////////

///////////////////////////////////////////////////////////////////////////

///////////////////////////////////////////////////////////////////////////

///////////////////////////////////////////////////////////////////////////

Q.3 KEYFOB PROGRAMING

Q.3 FOB # (1 thru 8)select: Fob Used (Used/Unused)

select: Equipment Code (see p.2)

enter: Serial Number (Same as RF Programing)

select: Equipment Age (New/Existing)

select: Emergency Key 0-Disabled 1-Auxilary 2-Audible 3-Silent Panic 4-Fire

select: Fob Can Disarm (Enabled/Disabled)

select: Voice Descriptor (Same as RF Programing. See p.2)

select: Fob Arm with No Delay (Enabled/Disabled)

select: Fob Output 0-Disabled 1-Toggle Output 2-Momentary Output

SUMMARY SCREENLook over sensor information to make sure all settings are satisfactory.Edit Next to add the next sensorSkip to move to Wired Sensor programingSkip (again) to move to Keyfob programing

Q.4 KEYPAD PROGRAMING

Q.4 KEYPAD # (1 thru 4)select: Keypad Used (Used/Unused)

select: Equipment Code (see p.2)

enter: Serial Number (Same as RF Programing)

select: Equipment Age (New/Existing)

select: Emergency Key (Enabled/Disabled)

select: Voice Descriptor (Same as RF Programing. See p.2)

SUMMARY SCREENLook over sensor information to make sure all settings are satisfactory.Edit Next to add the next sensorSkip to move to Wired Sensor programingSkip (again) to move to Keyfob programing

FIELD PROGRAMINGChange the Questions below accordingly:

CELL PRIMARY

2-WAY or DIGITALGo To: 13- enter 1 (2-way) enter 0 (digital)

Go To: 08-DisableGo To: 63-Disable

CELL BACKUPGo To: 08-EnableGo To: 63-EnableGo To: 11-Enter Receiver Line#Go To: 12-Enter CSID#

QUICK PROGRAMING GUIDE page2/////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////

/////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////

ZONE TYPES

VOICE DESCRIPTORS

[01] ENTRY/EXIT1 (DOORS)[02] ENTRY/EXIT 2 (DOORS BY CUST REQUEST[03] PERIMETER (WINDOWS/GLASSBREAK)[04] INTERIOR FOLLOWER (MOTION)[05] TROUBLE DAY/ALARM NIGHT[06] 24 HR SILENT[07] 24 HR AUDIBLE (POLICE)[08] 24 AUX (MEDICAL, PANIC, FREEZE, H2O)[09] FIRE/HEAT WITHOUT VERIFY (SMOKE/HEAT)[10] INTERIOR WITH DELAY (MOTION)[14] CARBON MONOXIDE (CO DETECTOR)[16] FIRE WITH VERIFICATION[23] NO RESPONSE[24] SILENT BURGLARY

EQUIPMENT CODES

0000 - OTHER0862 - DW10-345 THIN D/W (SURFACE) CONTACT0863 - DW20-345 RECESSED DOOR CONTACT0869 - PIR-345 MOTION WITH PET IMMUNITY0864 - GB1-345 GLASS BREAK DETECTOR0872 - SMKE1-345 SMOKE DETECTOR (USA)0871 - SMK1-345C SMOKE DETECTOR (CANADA)0868 - PANIC1-345 PANIC BUTTON REMOTE0860 - CO1-345 CO DETECTOR (USA)0859 - CO1-345C CO DETECTOR (CANADA)0873 - TAKE-345 TAKEOVER MODULE0866 - KEY1-345 KEYFOB0867 - PAD1-345 KEYPAD

0637 - HONEYWELL D/W “5816”0470 - HONEYWELL R-D/W “5818MNL”0533 - HONEYWELL PIR “5890”0530 - HONEYWELL PIR “5894PI”0519 - HONEYWELL GLASS BREAK “5853”0589 - HONEYWELL SMOKE “5008W3”0557 - HONEYWELL HEAT SENSOR “5809”0624 - HONEYWELL FLOOD SENSOR “5821”0491 - HONEYWELL PANIC PENDANT “5802MN2”

002 ABORT003 ac 004 access005 alarm006 and007 announcement008 area009 arm010 armed011 arming012 at013 attic014 audio015 auto016 automation017 auxiliary018 away019 BABYS020 back021 basement022 bathroom023 battery024 bedroom025 bonus026 break027 button028 bypass029 bypassed030 CABINET031 cancel032 carbon monoxide033 cellar034 cellular035 cell radio036 center037 check038 chest039 childrens

040 chime041 closet042 code043 communications044 computer045 control046 cool047 crawl048 current049 DAY050 degrees051 den052 detector053 dim054 dining055 disarm056 disarmed057 dock058 door059 downstairs060 driveway061 EAST062 eight063 eighteen064 eighty065 electric066 eleven067 emergency068 enter069 entrance070 entry071 error072 exercise073 exit074 exit now075 exterior076 external077 FAILURE

078 family079 fan080 �fteen081 �fty082 �re083 �re alert084 �re detector085 �rst086 �ve087 �ood088 �oor089 �uid090 foil091 for092 forty093 four094 fourteen095 fourth096 freeze097 freezer098 front099 furnace100 GAME101 garage102 gas103 glass104 glassbreak105 guest106 gun107 HALL108 hallway109 hanging110 hang up111 heat112 high113 home114 house115 ICE

116 inside117 instant118 interior119 intrusion120 is121 KEY122 keyfob123 keypad124 kids125 kitchen126 LAUNDRY127 left 128 level129 library130 light131 lights132 liquor133 living134 loading135 lock136 loft137 low138 MAIN139 maintenance140 master141 medical142 medicine143 menu144 middle145 monitor146 motion147 motion detector148 mud149 NINE150 nineteen151 ninety152 north153 not

154 not ready155 no delay156 no entry delay157 nursery158 OFF159 o�ce160 on161 one162 one hundred163 output164 outside165 PANEL166 panic167 pantry168 patio169 perimeter170 phone line171 play172 police173 pool174 pound175 power176 press177 previous178 pump179 RADIO180 ready181 rear182 relay183 remote184 repeat185 rf jam186 right187 room188 SAFE189 second190 security191 sensor

192 sensors193 session194 set195 seven196 seventeen197 seventy198 shed199 shop200 side201 silent202 siren203 six204 sixteen205 sixty206 skylight207 sliding208 smoke209 sounder210 south211 space212 spare213 stairs214 star215 status216 stay217 stop218 storage219 study220 sump221 supervision222 system223 TAMPER224 temperature225 ten226 terminated227 thermostat228 third229 thirteen

230 thirty231 three232 to233 tool234 transmitted235 transmitter236 trouble237 turn238 twelve239 twenty240 two241 UNLOCK242 upper243 upstairs244 user245 utility246 VALVE247 voice248 WALL249 water250 west251 window252 wireless253 YARD254 ZERO255 zone

Z-WAVE QUICK PROGRAMING GUIDE

IN SYSTEM CONFIGURATIONQ79: Enable/Disable Z-Wave Feature (1-3)Q80: Enable/Disable SwitchesQ81: Enable/Disable ThermostatsQ82: Select Fahrenheit/Celsius

LINKING A THERMOSTAT OR SWITCH

select: Home Servicesselect: Tool Boxenter: Master Code (default 1111)select: Add Devicespress/release: The binding button on the thermostat or switch2GIG-Z-STAT: PRESS MENU ON THE RIGHT, THEN MATE ON THE LEFT (TWICE)Allow time for the panel to download the devices informationselect: Backselect: Back

CREATING A SCENEselect: Scenesselect: Add Sceneenter: A Name for the Scene (eg, Disarm)select: OKselect: Add to create the sceneselect: Z-Wave Thermostat/Switchselect: Desired Mode and Setpoint for Thermostat ON/OFF for switchselect: OKselect: Backselect: Run to test sceneselect: Back

CREATING A RULE (if accessible locally)select: Rulesselect: Add Ruleselect: Event use right and left arrowsselect: Scene use right and left arrowsselect: Back

/////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////

/////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////

///////////////////////////////////////////////////////////////////////////

PRE SS Z-WAVEDEVICE BUTTON

add z-wave device screen

pressing the device’s programming button

linking the 2GIG Z-STAT

menumate (twice)

MATE