Quality CPR for Emergency Care Simulation Training Solutions
Resusci Anne® Simulator with SimPad®
The Resusci Anne® Simulator with SimPad® helps students and healthcare
professionals train to Quality CPR standards. With a live CPR feedback
and debriefing screen, coupled with basic airway management, vital signs
and spontaneous breathing features, the Resusci Anne with SimPad is
the new gold standard in training simulators for basic and intermediate
patient care assessment for emergency medical personnel.
Visit us for a comprehensive list of Resusci Anne Simulator
with Simpad features
©20
13 L
aerd
al M
edic
al.
All
right
s re
serv
ed.
Prin
ted
in U
SA
. 00
0187
68 R
ev. A
#1
3-13
582
Resusci Anne® Simulator with SimPad®
AIRWAY FEATURES:
• Bag-Valve-Mask ventilation• Oropharyngeal Airway insertion• Nasopharyngeal Airway insertion• Laryngeal Mask Airway insertion and ventilation• Laryngeal Tube Airway insertion and ventilation• Combitube insertion and ventilation• Sellick Manuever (cricoid pressure)• Spontaneous breathing with realistic chest rise and fall - On/Off and rate controlled via SimPad - SpO2 and etCO2 settings
• “Chin Lift” and “Jaw Thrust” and “Head Tilt” sensors including tongue fall back• Airway closing mechanism (located in torso) - Overrides an open airway to simulate an obstruction at any time - Open or closed airway status operated via SimPad Control unit
CIRCULATION FEATURES:
• Eyes for pupil assessment Normal - Dilated - Constricted • Automatically generated carotid pulses synchronized with ECG Bilateral carotid, brachial and radial pulses Pulse strengths dependent on BP or set individually Brachial pulse off when BP cuff pressure is above 20mmHg Radial pulse off when BP cuff pressure is above Systolic BP level• Auscultated and palpated blood pressure simulation Korotkoff sounds synchronized with ECG Systolic and diastolic pressure may be set individually in steps of 2mmHg Systolic 0-300mmHg, Diastolic 0-200mmHg Auscultative Gap, with on/off feature Pressure accuracy +/- 4mmHg Brachial and radial pulse control, palpated BP function • Defibrillation capabilities (25-360j) 4 - Lead ECG monitoring Synchronized variable rate, rhythm, abnormalities, and duration
HEART SOUNDS (Synchronized with programmable ECG):
• Aortic Stenosis• Friction Rub• Austin Flint Murmur• Diastolic Murmur• Systolic Murmur• Mitral Valve Prolapse• Opening Snap 70ms• Normal
SimCenter
Visit www.mysimcenter.com to learn how to optimize your simulation training using SimCenter and SimPad
For more information, visit laerdal.com
Operat ion
Resusci Anne Simulator is operated by the SimPad Remote control allowing easy navigation through simulation based education.
Serv ices
Laerdal offers comprehensive Educational Services to support your curriculum, and Technical Services to meet your simulator servicing needs.
SimStoreAccess to validated, standardized content from industry experts
SimManagerA suite of online tools that allows you
to fully optimize your entire simulation center operation
SimViewAn integrated debriefing solution giving you
the ability to study simulation events more closely
LUNG SOUNDS (Synchronized with breathing rate, 0 – 60 breaths per minute with individual lung or bilateral sound selection):
• Normal• Crackles• Pneumonia• Stridor• Wheezes• Rhonchi• No sound
VOCAL SOUNDS (Computer-generated sounds, mixed with live voice input via headset – sold separately):
• Cough• Vomit• SOB Breathing• Moan• Scream• Yes• No ORDERING INFORMATION:
150-20001 Resusci Anne Simulator with SimPad Includes: Torso with Extrication Rescue Legs, SimPad (Link Box with Lithium-Ion Battery Installed in Manikin), Air Pump, Blood Pressure Cuff, Manual Defibrillation Plates, 3 Eye Sets (Normal, Constricted, Dilated Pupils), (2) AC Adapters, USB Cable, Simulated Blood, Lubricant, Full-Body Soft Pack Carry Case, Resusci Anne Track Suit, User Guide and Important Product Information Booklet.