5

Default Setup values are give in BOLD*Changing these values while the device is in use, is not recommended.

SYS= Power system's configuration*: STAR, DELTA, 2phase, 1phase, WYE

V.PRI= Voltage primary winding (PT), line-line* Input range: 100 V to 999 kV (415.0)

V.SEC= Voltage secondary winding (PT), line-line*Input range: 80 V to 600 V (415.0)

A.PRI= Current primary winding (CT)*Input range: 1 A to 99 kA (100.0)

A.SEC= Current secondary winding (CT) (5.000)

LABL= Phase labeling Choose from: 123, RYB, RST, PQR, ABC

VA.FN= VA function selection*Set the VA function to: 3D, ARTH

F.S%= Full scale %Set the full scale between1 to 100: 100

POLE = Number of poles for RPMChoose from 2, 4, 6, 8, 10, 12, 14, 16

BAUD= Baud rate : 1200, 2400, 4800, 9600, 19200.

ID = RS485 Device ID number: 001 to 247.(Evn.1 = Even.1 stop bit)

PRTY= Parity & Stop bit settings: EVN.1, EVN.2, ODD.1, ODD.2, no.1, no.2

O.F = Overflow parameter selection :Wh, Vah – INTG clears when 9999 Run hours ( almost 13.88 months)

EDITA.PRI100.0

EDITA.SEC5.000

EDITV.PRI415.0

EDITV.SEC415.0

EDITSYS

STAR

EDITLABL123

EDITBAUD9600

EDITPRTYEVn1

EDITID

1.000

EDITF.S%100.0

EDITOVF.P

Wh

EDITPOLE4.000

EDITVA.Fn

3D

VIEWA.PRI100.0

VIEWA.SEC5.000

VIEWV.PRI415.0

VIEWV.SEC415.0

VIEWSYS

STAR

VIEWLABL123

VIEWBAUD9600

VIEWPRTYEVn1

VIEWID

1.000

VIEWF.S%100.0

VIEWOVF.P

Wh

VIEWPOLE4.000

VIEWVA.Fn

3D

EDITMODE

VIEWMODE

d.SEL = Demand Selection* : auto, userEDITd.SELAUTO

VIEWd.SELAUTO

d.PAR = Demand Parameter* : VA, W, AEDITd.PAR

VA

VIEWd.PAR

VA

d.PRD = Demand Period: 5,10, 15, 20, 25, 30EDITd.PRD15.00

VIEWd.PRD15.00

NOTE: indicates blinking / editable

1 means blinking 1

PASSCODE1 000

CODE2 000EDITCLR

RMS

SET VIEW

RMS

CLR

SET VIEWVIEWA.PRI100.0

SET

RMS

CLREDITA.PRI100.0

VIEW

EDITEDITA.PRI100.0

EDITA.PRI200.0

EDITA.PRI210.0

EDITA.PRI220.00

EDITA.PRI220.0

NOTE: indicates blinking / editable

E.g. 2 means blinking y

EDITA.PRI200.0

NOTE: indicates blinking / editable

E.g. y means blinking y

EDITA.PRI220.0

SAVE yPASS

SAVE nFAIL

EDITSET

NOTE: indicates blinking / editable

E.g. y means blinking y

CLRCLRINTG

CLRINTG PASS

CLRINTG FAIL

CLRMD

CLRMD PASS

CLRMD FAIL

n

y

n

n

RMS