3
QITTM Crash Cushion Attenuating Terminal System Features: . Can be used as a longitndinal barrier and as a crash cushion either in the median or on the shoulder. . Various post and post/sleeve options are avail- able. Available in weathering steel. NCIIRPReport 350 Test Level3 compliant. a a The Firelands Supply Co. is a stocking distributor of the assembly and parts of the QdFu Crash Cushion Attenuating Terminal. This energy-absorbing attenu- ator is used where blunt ends of rigid barriers and fixed objects are in the median or on the shoulder. ffue Qdfru assernbly has some installation and repair advantges, such as, there are no torque requirements on bolts. It can be installed in soil, no concrete pads required. Foundations and deadmen anchors are not required. Material below ground is typically found un- damaged after impact, allowing for simple repair and replacement of damaged parts. CATTM TERMINAL USAGE . HIGHWAY . PERMANENT . UNDIRECTIONAL TRAFF'IC . BI-DIRECTIONAL TRAF'FIC . BRIDGES/TT]NNELS SPECIFICATIONS: . SYSTEM LENGTH 3I,3'' . TOTALNUMBEROF POST 6 . SYSTEM WIDTH 24'' INSIDE / 30" OUTSIDE . SYTEM HEIGTH 27.75" TOP OF RAILS PN QTY DBSCRIPTION 3lG 2 l2ll2' 6"10 cAT (GUARDRATL) l30A 2 10112' 6" /s' 10:6' 8/SP CAT (GUARDRAIL) 705G 1 2"x5l/2"PIPE 740G 6 4'6" TUBE SLEEVE 766G 6 ll4" x 18" x 24" SOIL PLATE 782G I 5/8" x 8" x 8" BEARING PLATE 983G I I O/NOSE PLATE/CAT/ROLLED 984G 2 IO/SIDE PLATE CAI 3012G I CABLE 3/4" x 8'/DBL SWG 30748 5 wD 3' 6" POST # 2, 3, 4, 5, 6 CNI 3075B I WD 3'6'' POST #1 CAT 31008 2 WD BLOCK 1'2# l CAT 3 t01B l0 wD BLOCK l'2#2,3,4,5,6 CNI 3263G 4 3/8" x2" LAG SCREW 32'75G 2 3/8" x 24 1/2' RESTRAINT ROD 3300G 20 5/8" FLATWASHER 3320G 4 3116" x I 314" x 3' RECTANGLE WASHER 3340G 85 5/8" GRNUT 3360G l6 5/8" x I l/4" GR BOLI 3380G 8 5/8" x I 1/2" HEX BOLI 3395G 32 5/8" x 1 314" HEX BOLI CAT 3478G 13 5/8" xi 1/2" HEX BOLI 3497c 6 518" x9 1/2" HEX BOLI 3650G 2 518" x25" GR BOLI 3900G 2 1''FLATWASHER 39r0G 4 l"HEXNUT 4252G 8 3/8* HEXNUT 325sG 4 3/8" FLATWASHER 4258G 4 3/8" LOCKWASHER 4640G 8 518" x24" HEX BOLT 98s24 I CHANNEL STRUT 6'- 6'' 99154 SPACER CHANNEL CAT 99161. IO/BENT PLATE SLEEVE 9921G 2 6"SLEEVE6x8 t9259G 32 3116" x2" x 10" PLATE WASHER t926tG 2 Il2" x3 x 7 POST PLATE t927tG 1" x2l/2" PIPE SLEEVE CAT 591 88 YELLOW REFLECTIVE SHEETING

QITTM Crash Cushion Attenuating Terminal - · PDF fileQITTM Crash Cushion Attenuating Terminal ... x 8" BEARING PLATE 983G I I O/NOSE PLATE/CAT ... RESTRAINT ROD 3300G 20 5/8" FLATWASHER

Embed Size (px)

Citation preview

Page 1: QITTM Crash Cushion Attenuating Terminal - · PDF fileQITTM Crash Cushion Attenuating Terminal ... x 8" BEARING PLATE 983G I I O/NOSE PLATE/CAT ... RESTRAINT ROD 3300G 20 5/8" FLATWASHER

QITTM Crash Cushion Attenuating Terminal System

Features:. Can be used as a longitndinal barrier and as

a crash cushion either in the median or on theshoulder.

. Various post and post/sleeve options are avail-able.Available in weathering steel.NCIIRPReport 350 Test Level3 compliant.

a

a

The Firelands Supply Co. is a stocking distributor ofthe assembly and parts of the QdFu Crash CushionAttenuating Terminal. This energy-absorbing attenu-ator is used where blunt ends of rigid barriers andfixed objects are in the median or on the shoulder.ffue Qdfru assernbly has some installation and repairadvantges, such as, there are no torque requirementson bolts. It can be installed in soil, no concrete padsrequired. Foundations and deadmen anchors are notrequired. Material below ground is typically found un-damaged after impact, allowing for simple repair andreplacement of damaged parts.

CATTM TERMINAL USAGE

. HIGHWAY. PERMANENT. UNDIRECTIONAL TRAFF'IC. BI-DIRECTIONAL TRAF'FIC. BRIDGES/TT]NNELS

SPECIFICATIONS:. SYSTEM LENGTH 3I,3''. TOTALNUMBEROF POST 6. SYSTEM WIDTH 24'' INSIDE / 30" OUTSIDE. SYTEM HEIGTH 27.75" TOP OF RAILS

PN QTY DBSCRIPTION3lG 2 l2ll2' 6"10 cAT (GUARDRATL)

l30A 2 10112' 6" /s' 10:6' 8/SP CAT (GUARDRAIL)

705G 1 2"x5l/2"PIPE740G 6 4'6" TUBE SLEEVE

766G 6 ll4" x 18" x 24" SOIL PLATE

782G I 5/8" x 8" x 8" BEARING PLATE

983G I I O/NOSE PLATE/CAT/ROLLED

984G 2 IO/SIDE PLATE CAI3012G I CABLE 3/4" x 8'/DBL SWG

30748 5 wD 3' 6" POST # 2, 3, 4, 5, 6 CNI3075B I WD 3'6'' POST #1 CAT

31008 2 WD BLOCK 1'2# l CAT

3 t01B l0 wD BLOCK l'2#2,3,4,5,6 CNI

3263G 4 3/8" x2" LAG SCREW

32'75G 2 3/8" x 24 1/2' RESTRAINT ROD

3300G 20 5/8" FLATWASHER

3320G 4 3116" x I 314" x 3' RECTANGLE WASHER

3340G 85 5/8" GRNUT

3360G l6 5/8" x I l/4" GR BOLI

3380G 8 5/8" x I 1/2" HEX BOLI3395G 32 5/8" x 1 314" HEX BOLI CAT

3478G 13 5/8" xi 1/2" HEX BOLI

3497c 6 518" x9 1/2" HEX BOLI3650G 2 518" x25" GR BOLI3900G 2 1''FLATWASHER

39r0G 4 l"HEXNUT4252G 8 3/8* HEXNUT

325sG 4 3/8" FLATWASHER

4258G 4 3/8" LOCKWASHER

4640G 8 518" x24" HEX BOLT

98s24 I CHANNEL STRUT 6'- 6''

99154 SPACER CHANNEL CAT

99161. IO/BENT PLATE SLEEVE

9921G 2 6"SLEEVE6x8

t9259G 32 3116" x2" x 10" PLATE WASHER

t926tG 2 Il2" x3 x 7 POST PLATE

t927tG 1" x2l/2" PIPE SLEEVE CAT

591 88 YELLOW REFLECTIVE SHEETING

Page 2: QITTM Crash Cushion Attenuating Terminal - · PDF fileQITTM Crash Cushion Attenuating Terminal ... x 8" BEARING PLATE 983G I I O/NOSE PLATE/CAT ... RESTRAINT ROD 3300G 20 5/8" FLATWASHER

The ET:PLUSTM is a cost-effectiveo energy-absorbing end terminal

Features:. Tall and narrow extruder head.. Softer ride down for smaller vehicles.. Lighter weight head helps ease installation.. NCHRP Report 350 Test Level 2 and,Test Level3compliant.

. ET-PlusrM head is sometimes reusable after a NCIIRPReport 350 criteria impact.

The Firelands Supply Co. is a fulI stocking distributor of the ET-PLUSTM assembly and parts. Thisenergy-absorbing end treatment, is O.D.O.T and Federally approved. It can be used at the termination offlexible barriers on the shoulder of a roadway or in the median. The ET-PLUSTM is a cable-anchored systemdesigned, when hit head on, to bring vehicles to a controlled stop. In the case of a side impact, the systemacts just as a nofinal guard rail, redirecting the vehicle towards its original path.

PN QTY DESCRIPTION

60G 12125' 16',3" lS (GUARDRAIL)

62G l2/25', 16',3" /S ANC (GUARDRAIL)

7044 CABLEANCHORBRACKET705G 2" x5l/2"PWE740G 2 4'- 6TUBE SLEEVE

749G 2 6'TUBE SLEEVE

782G 5/8" x 8" x 8" BEARING PLATE

995A ET-PLUS EXTRUDER

3000G CABLE 314x6'6"3300G 7 5/8"WASHER

3340G 29 5/8" HEXNUT3360G t6 5/8" x I l/4" SPLICE BOLT

3478G 4 518" x7 ll2 HEX HEAD BOLT

3497G 2 5/8" x 9 l/2" }lEX HEAD BOLT

3s00G 5/8" x 10" POST BOLT

3s80G 6 5/8" x 18" POST BOLT

3700G 4 3/4"WASHER

3704G 2 3/4'' HEXNUT3900G 2 [,, WASHER

3810G 2 I" NUT4063B, 4 6" x 8" x 6'WOOD POST

40758 6 6" x8" x l'2 WOOD BLOCK

41478 4 5l/2" x7 ll2" x 3'9 WOOD POST

4228G 2 3/8" x4" LAG SCREW

5148G 2 3/4" x9112" HEX HEAD BOLT

3387sG ANGLE STRUT

END TERMINAL USAGE

. HIGIIWAY

. PERMANENT

. L]NDIRECTIONAL TRAFFIC

. BI-DIRECTIONAL TRAI]FIC

. BRIDGES/TIINNELS

. MUNICIPAL/CITY

SPECIFICATIONS:

. OFFSET:0TO2'

. LENGTH: 25'TEST LEVEL 2 & 50'TEST LEVEL 3

. POST SPACING: 6'3"

Page 3: QITTM Crash Cushion Attenuating Terminal - · PDF fileQITTM Crash Cushion Attenuating Terminal ... x 8" BEARING PLATE 983G I I O/NOSE PLATE/CAT ... RESTRAINT ROD 3300G 20 5/8" FLATWASHER

SRT-350TM @-98) Slotted Rail Terminal, 8 Post System is a gating, flared end terminal.

Features:

.3' - 4o offset results in reducedinstallation costs.

. fmproved angle sfruts allow for easierinstallation.

. Fewer post and a straight layout providecost savings in construction, makingreplacement easier.

The SRT-350rM System has 2 steel tube sleeves with breakaway wood posts, and 6 wood CRT posts. Thissystem installs on a offset flared dimension, with a style similar to previously used BCT's and MELT'smaking replacement easier. Strategically located slots in the W-Beam rail enhance SRT-350rM perfor-mance. call The Firelands Supply Co. for all your guardrail end treatment requirements.

PN QTY DESCRIPTION9G I r2l 12' 61 6' 3 /S (GUARDRAIL)

30c I I2l 12', 61 6', 3 lS SRT- 1 (GUARDRAIL)

39G I r2l t2' 6ls sRT-2 (GUARDRATL)

700A I CABLEANCHOR BRACKET

705G 1 2" x5ll2"PLPF,742G 2 6'0 TUBE SLEEVE

775G I 5/8"x6x8BEARINGPLATE907G 1 I 2/BUFFER/ROLLED (TERMTNAT)

3000c I 314x6'6 CABLE

3300c 20 5/8'' WASHER

3340G 62 5/8" HEX NUT3360G 44 5/8" x I ll4" SPLICE BOIif3380G 8 5/8" x I ll2" HEX HD BOLI3497G 2 5/8" x9ll2" HEX HD BOLT

3500G 2 5/8" x 10" POST BOLT

3580G 6 5/8" x 18" POST BOLI3900G I 1" WASHER

3910G 2 1'' HEX NUT40638 6 6'0 POST 6" x 8"40758 6 14" BLOCK 6" x 8"

6058B 2 3'9" POST 5 112" x7 ll2"s968G 2 l6dNAIL SRT

9852lt I STRUTASSEMBLY

9960G 4 SLOT GUARD

9961c I 3/8" x 3" x 4" PLATE WASHER

SRT-35OTM END TERMINAL USAGE

.HIGIIWAY

.PERMANENT

.UNDIRECTIONAL TRAFFIC

.BI-DIRE CTIONAL TRAFFIC

.BRIDGES/TT]NNELS

.MUNICIPAL/CITY

SPECIFICATIONS:. OFFSET 3'TO 4'. SYSTEM LENGTH 37'6". LENGTH OF NEED 12'6" FROM THE END

OF THE TERMINAL (AT 3rd POST). STRAIGHT FLARE OPTIONS