Q U I C K S E R V I C E D O O R S
A range of rationalised doorsets, designed to streamline the order process
Version 1.0 - 2020
WHY SHOULD YOU CHOOSE AHMARRA?
QUALITY We use the finest materials, cutting edge technology and traditional craftsmanship to guarantee exceptional standards.
GREEN We care about the environment, our materials are FSC® certified and we hold ISO 14001 certification for our environmental practices. Our wood waste is converted into heat for our production facility in our biomass boiler. Our local forest planting scheme has meant thousands of plants and trees have been planted as a result of our donations.
BRITISH Made in Britain to the highest quality standards, we are proud to fly the flag for UK manufacturing.
2
Our Quick Service Doors are a rationalised range of pre-hung bespoke doorsets.
This brochure seeks to simplify the options, streamlining the process with materials stocked and ready to go. This range is designed to eliminate the usual RFI’s so that your performance fire doorsets can be delivered with a reduced lead-time.
Follow the simple steps and complete the form at the back of the brochure by using the drop-downs to select the options code and email it to [email protected] for a fast-track quotation.
3
The Importance of Fire Doors and Third Party CertificationFire doors save lives and protect property, so it is vital that they are manufactured and installed correctly, or their fire-resistance can be seriously compromised. Third party certification provides an additional level of assurance of boththe level and consistency of performance.
Q-Mark Fire Door Manufacturer SchemeAhmarra are proud to be certified members of this comprehensive third party certification scheme. Q-Mark has been designed to allow fire door manufacturers to demonstrate that their doors meet the standards required, and to provide ongoing reassurance that their product is fit for purpose. Performance, and production are regularly checked through audit testing and inspections.
BM TRADA Q-MARK CERTIFICATION
Pre-hung doorset Single doors will arrive fitted on its hinges and perfectly fitted into its frame. Double doors will arrive with frame assembled but doors removed for manual handling purposes (unless door only ordered)
Architrave and stops supplied loose
Hinges, intumescent, drop seals (if acoustic or smoke controlled door) fitted at works
Doors can also be supplied and morticed only for one of our lock cases, or flush bolts on double doors (if required)
Plugged to confirm Q-Mark Fire Door Certification
Palletised and express delivered to your project
Full set of installation instructions
Ironmongery is not included (other than our tested hinges), but can be supplied separately upon request
YOUR DOORSET WILL INCLUDE:
4
DO
OR
CO
NF
IGU
RA
TIO
N,
FIR
E A
ND
AC
OU
ST
IC O
PT
ION
S
QU
ICK
SE
RV
ICE
DO
OR
SE
LE
CT
ION
5
Technical Details Door Core
UNEQUAL PAIR OF DOORS
SeverecoreTM
Specification
Configuration
Vision Panel
Technical Details Door Core SeverecoreTM
DOUBLE DOORS
Double
Yes/No
Configuration
Vision Panel
Specification
Technical Details
Fire Rating
Door Core
Configuration
Vision Panel
SeverecoreTM
SINGLE DOOR
Single
Yes/No
Acoustic Rating Rw(dB)*
Specification
Replace image
SINGLE UNEQUAL PAIR EQUAL PAIR
S U E
CODE 1: DOOR CONFIGURATION
QUICK SERVICE DOOR CONFIGURATIONSSelect the most appropriate door configuration for each structural opening.
Fire Rating Acoustic Rating Rw(dB)* Fire Rating Acoustic Rating Rw(dB)*
NON-FIRE RATED FD30 FD60
FD30SMOKE
CONTROL
FD60SMOKE
CONTROL
NFR FD30 FD60 FD30/S FD60/S
CODE 2: FIRE RATING
Ensure each door has the correct fire rating associated, NFR, FD30 or FD60. This should be derived from the building’s fire strategy, by a professional.
FD30 and FD60 doors are also available with smoke control. Smoke controlled doors will have a drop seal fitted.
When doors only are ordered intumescent is not supplied, machined or fitted by Ahmarra.
NON-ACOUSTIC RATED
30 RwdB 35 RwdB
NR 30 35
CODE 3: ACOUSTIC RATING
If noise reduction is required, please select the appropriate acoustic rating.
All acoustically attenuated doors require a drop seal and will also be fitted to smoke controlled doors allowing an 8mm gap below your fire door which will be sealed when door is in closed position
FD60
FD30NFR NR 30 35FD
60FD30NFR NR 30 35FD
60FD30NFR NR 30 35
Unequal Pair
Yes/No
7 6
Design Considerations
FA
CIN
GS
& F
INS
IHE
S A
ND
VIS
ION
PA
NE
LS
DO
OR
SE
T F
EA
TU
RE
S
NO APERTURE STANDARD VISION PANEL
None VP01
VP01Single narrow vision panel
Vision panels allow users of the building to view what is on the other side of the door and are an important safety feature, vital in preventing injury resulting from collision with opening doors.
BS 8300:2009
MINIMUM ZONE OF VISIBILITY
FD60
FD30NFR
Technical Details
Aperture Width
Aperture Height
200 mm
1400 mm
Fire Ratings
VISION PANELStandard vision panel style details, DDA compliant to BS 8300:2009.
CODE 5: VISION PANEL
Choose whether you would like your doors to feature a vision panel.
Pre-Primed Veneer
The pre-primed paper has been designed as a time saving initiative for paint grade doors and is ideal for concealing any lippings ensuring a smoother finish.
PRIMED ECO-VENEERReady Primed Eco-Veneer suitable for on-site painting.
- Economic
- Surface damage can easily be fixed on-site
- Can be painted on-site to match the project’s design scheme
- FSC® certified
Benefits
FACINGS & FINISHESFrames will be pre-primed. Doors can either be primed for on-site painting or factory finished with high pressure laminate selected from the options below.
PRIMED ECO-VENEER
BLANCARTIC
BLANC MEGÈVE
GRISTOURTERELLE
GRISPERLE
GRISCENDRE
GRISACIER
PRIMED B117 B070 G029 G003 G075 G076
CODE 4: FACINGS & FINISHES
HIGH PRESSURE LAMINATEAhmarra supply laminate from Polyrey®.
- Highly resistant surface (impact, abrasion, stains, chemicals)
- Nonporous surface: easy to clean and resistant to disinfection protocols
- Antibacterial Sanitized® treatment as a standard, eliminates 99.9% of bacteria on the surface
- FSC® certified
- Volatile organic compounds (VOCs): Greenguard Gold Certified
- Suitable for high-traffic public environments
Benefits
B117 FABlanc Artic
G075 FAGris Cendre
B116 FABeige Nature
B070 FABlanc Megève
G076 FAGris Acier
R062 FARouge Fatal
G029 FAGris Tourterelle
G059 FAGris Orage
B086 FABleu Caraïbes
G003 FAGris Perle
N005 FANoir
D018 FAChêne de Meymac
The laminate is available in 13 colour options. We keep stock of these standard colour options;
B100 FABanian Blanchi
GRISORAGE
NOIR BEIGE NATURE
ROUGE FATAL
BLEUCARAÏBES
CHÊNEDE MEYMAC
BANIAN BLANCHI
G059 N005 B116 R062 B086 D018 B100
Bolection BeadHardwood bolection bead (cloak bead)will also be in American White Oak, where laminate, to match the lippings. Pin fixed.
LIPPINGS & GLAZING BEADS
LippingsAll doors from Ahmarra are lipped all around.
Laminate faced doors will be lipped in American White Oak (semi-concealed as shown).
9 8
FR
AM
E,
AR
CH
ITR
AV
E,
HIN
GE
, H
AN
DIN
G &
LO
CK
S
DO
OR
SE
T F
EA
TU
RE
S
FRAMES & ARCHITRAVE
Our most popular frame type, suitable for most project types.
Frame finish is primed for on-site decoration.
Seals will always be white and can be painted over.
Technical Details
Min. Wall Depth
Max. Wall Depth
Fire Rating
75 mm
250 mm
NFR, FD30, FD60
LINING WITH PLANTED DOOR STOPS (LNG)
- Overall cost saving
- Natural timber defects eliminated
- Consistent material appearance
- Long term product stability
- Overall cost saving
- Natural timber defects eliminated
- Consistent material appearance
- Long term product stability
DensityFire ratingFinish
DensityFire ratingFinish
>470Kg/M3 NFR, FD30
Primed for on-site painting
>650 Kg/M3 FD60
Primed for on-site painting
FRAME MATERIALS
Engineered Softwood (ESWD) Engineered Hardwood (EHWD)
PRIMEDFOR ON-SITE PAINTING
PRIMEDFOR ON-SITE PAINTING
HINGESIn fire door applications, three hinges must be fitted to each door. Lift off hinge and butt hinge options are available.Where door only, hinges can be supplied for on-site machining and fitting to align with existing frames.
LIFT OFF HINGES
BUTT HINGES
NONE
LO BT N/A
CODE 7: HINGE
LIFT OFF HINGESClass 11
Supplied and fitted by Ahmarra
BUTT HINGESSSS Class 13
Supplied and fitted by Ahmarra
HANDINGBe sure to select the correct handing for each doorset.
Standing on the non-hinge side (door opening away), if the door opens towards the right then it is a right handed door. If it opens towards the left it is a left handed door.
LEFT HAND RIGHT HAND NONE
LH RH N/A
CODE 8: HANDING
Left Hand Right Hand
ARCHITRAVE
Standard (44 x 18 mm)EDARC1
Ahmarra’s standard architrave profile is 44 x 18 mm with 3mm radiused edges.
DOOR SIZES DOORSET SIZES
DOOR HEIGHT x DOOR WIDTH
STRUCTURAL OPENING HEIGHT x STRUCTURAL OPENING WIDTH x
FRAME DEPTH + UNDERCUT
CODE 6: SIZESFor doors only, enter the door height and width in millimetres. For doorsets (doors pre-hung in frame), enter the structural opening height and width, plus the partition depth in millimetres.
Extended (69 x 18 mm)EDARC2
Extended architraves (69 mm wide) may be necessary for refurbishment projects where structural openings may be inconsistent.
LOCK MORTICEAhmarra can mortice for our modular lock and flush bolt if required.
LOCK MORTICE FLUSH BOLTS RECESSED
LOCK & FLUSH BOLTS RECESSED
NONE
LM FBR L&FBR N/A
CODE 9: LOCK FLUSH BOLTS
FLUSH BOLT2 x flush
bolt recess
SASHLOCKFlush bolts will be edge mounted if required. Modular lock-body only will be factory morticed into the door edge and positioned so that when fitted on site, the lever handle sits at 900mm height.
Where door only, locks can be supplied for on-site machining and fitting.
ARCHITRAVE SIZE OPTION 1
ARCHITRAVE SIZE OPTION 2
NONE
44mm 69mm N/A
CODE 6: ARCHITRAVE
1 0
SCREENS, INTERNAL WINDOWS & FANLIGHTSScreens and fanlights provide transfer of natural light in internal spaces. Standard configurations are shown below.
SC
RE
EN
S,
INT
ER
NA
L W
IND
OW
S &
FA
NL
IGH
TS
QU
ICK
SE
RV
ICE
SC
RE
EN
S
1 1
SIDE SCREEN (SS01)Screen adjacent to a door.
FANLIGHT (FL01)Screen above a door.
SIDE SCREEN & FANLIGHT (SSFL01)Side screen with adjacent fanlight.
Technical Data Technical Data
Max screen width Fire rating
900mmNFR, FD30, FD60
Max screen width Fire rating
To suit doorNFR, FD30, FD60
Technical Data
Max screen width Fire rating
900mmNFR, FD30, FD60
INTERNAL WINDOW (IW01)Screen, elevated from floor level. Screen not attached to door.
Technical Data
Max screen width Fire rating
N/ANFR, FD30, FD60
Technical Data
ELEVATED SIDE SCREEN (SS02)Side screen elevated above the ground.
Max screen width Fire rating
N/ANFR, FD30, FD60
MULTIPLE SCREENS (SS03)Single door with multiple side screens.
Technical DataMax screen width Fire rating
900mm each moduleNFR, FD30, FD60
Specification Code
Acoustic Rating
Fire Rating
Fire Insulation
Insulation Classification
Safety Ratings
Glass Thickness
Minimum Frame Depth
SRB-35-0 35 RwdB NFR 0 1B1 6.8 mm 75 mm
SRB-40-0 40 RwdB NFR 0 1B1 12.8 mm 85 mm
SRB-46-0 46 RwdB NFR 0 1B1 8.8 mm12 mm Spacer8.8 mm
100 mm
SRB-50-0 50 RwdB NFR 0 1B1 12.8 mm12 mm Spacer12.8 mm
110 mm
SRB-51-0 51 RwdB NFR 0 1B1 16.8 mm12 mm Spacer16.8 mm
115 mm
SRB-34-30 34 RwdB FD30 0 EW 3B3 7 mm 75 mm
SRB-44-30 44 RwdB FD30 0 EW 3B3 1B1
7 mm12 mm Spacer8.8 mm
100 mm
SRB-39-60 39 RwdB FD60 30 EI 2B2 16 mm 85 mm
SRB-40-60 40 RwdB FD60 60 El 1B1 25mm 95 mm
SRB-45-60 45 RwdB FD60 30 El 2B2 1B1
16mm12 mm Spacer6.8mm
105 mm
GLAZING CONFIGURATIONSInsulating GlassAhmarra would recommend the architect / BCO refer to Approved Document B of the Building regulations: Table A4, which gives guidance on the ‘Limitations of the use of uninsulated glazed elements on escape routes’.
Classification
EW= Integrity and low heat radiation or the ability of the element to prevent the passage of flames and to limit the level of heat transfer through the element
EI= Integrity and insulation or the ability of the element to prevent the passage of flames and to block the heat transfer through the element.
The required fire protection rating is specified by the respective national building regulations following a risk assessment based on the building characteristics and the location of the fire rated element (facade, partitioning walls, stairways etc).
Safety Rating
For glass to be classified as an impact-safe material, it must undergo the Safety Standard Test. This test is used to define the level at which glass will ‘break safely’, meaning there will be no large shards of glass, only small fragments that will cause less injury.
The classifications within BS EN 12600 are;
Class 1B1 (highest performing)
Class 2B2
Class 3B3 (lowest performing)
QUICK SERVICE DOORS ENQUIRY FORM
For a fast-track quotation, please send this completed form to [email protected].
Door Number
1Door
Configuration
2Fire Rating
3Acoustic Rating
4Facing/Finish
5Vision Panel
6Door Size Height
(mm)
6Door Size Width
(mm)Quantity
Company Name:
Contact Name:
Email:
Tel No: Project:
Or to discuss your requirements, please call 02392 389 076.
DOOR ONLY
Doorset Number
1Doorset
Configuration
2Fire
Rating
3Acoustic Rating
4Facing/Finish
5Vision Panel
6Structural Opening
Height (mm)
6Structural Opening
Width (mm)
6Frame Depth (mm)
6Undercut
(mm)
6Architrave
(mm)
7Hinges
8Handing
Ahmarra Convention
9Lock Quantity
DOORSET (DOOR PRE-HUNG IN FRAME)Left Hand Right Hand
QUICK SERVICE SCREENS ENQUIRY FORMFor a fast-track quotation, please send this completed form to [email protected].
Screen Number
Screen Type Specification Code (see Glazing Configuration table on page 11)
Screen Frame Height (mm)
Screen Frame Width(mm)
Frame Depth(mm)
Quantity
Company Name:
Contact Name:
Email:
Tel No: Project:
Order Form Submitted
Quote Issued
Order Confirmed & Payment Made
Doors Delivered
ORDER PROCESSOur QSD range reduces our current lead-time by two weeks by saving time at the front end through rapid quote generation, reduced RFI’s and having materials in stock.
Doors in Production