PURIFIED WATER
The water that has been
treated to filter out
sediments, remove alldissolved minerals and kill all
micro organisms.
8/10/2019 Purified Water Generetion System Operation1
3/13
BORE WELL
(RAW WATER
SOURCE)
SODIUMHYPO
CHLORITE
SOLUTION
(CHLORINE
DOSING)
The raw water is having suspended solids, dissolved impurities, colloids, organics, bacterialimpurities etc and resulting in high TDS of the Raw Water. All the impurities will foul the RO
membranes or any filters if used down stream. Hence, it is proposed to reduce the impurities to
desired level by pre-treatment.
Sodium H ypo Chlor ite Dosing Soluti on: -Provided to disinfect the feed water as well as control
the bacterial concentration in the subsequent steps. Free chlorine is maintained around 1 2 ppm.
Free chlorine in water reduces the possibility of bacterial germination in Multi grade filter andSoftener, which are otherwise potential breeding ground.
8/10/2019 Purified Water Generetion System Operation1
4/13
MGF SERVICE CYCLE
RWP
FI
FROMBOREWELL
Multi Grade Fil ter: -
MGF is provided to reduce
turbidity & suspended
particles up to 100. MGF
is designed with multi
layer of pebbles, gravels
and mix sand.
8/10/2019 Purified Water Generetion System Operation1
5/13
SOFTENER SERVICE
FROMMGF
BMT
BRINE
SOL.
TANK
(NaCl)
Softener unit is provided to
reduce the hardness of water up
to
8/10/2019 Purified Water Generetion System Operation1
6/13
NORMAL OPERATION OF
SOFTENER
Ca(HCO3)2 + 2NaR CaR2 + 2NaHCO3(Calcium bicarbonate) ( Sodium Resin ) (Calcium Resin) (Sodium bicarbonate)
MgSO4 + 2NaR MgR2 + Na2SO4(magnesium sulphate) (Sodium Resin ) (magnesium Resin) (Sodium sulphate)
Regeneration of Softener
CaR2 + 2NaCl 2NaR + CaCl2
(Calcium Resin) (Sodium Chloride) (Sodium Resin) (Calcium Chloride)
MgR2 + 2NaCl 2NaR + MgCl2(Magnesium Resin) (Sodium Chloride) (Sodium Resin) (Magnesium Chloride)
8/10/2019 Purified Water Generetion System Operation1
7/13
FI
FEED
REJECT
U
F
UF PRODUCT STORAGE TANK 1101
M
C
F
TANK
Micro n Cartr id ge Fil ter (MCF):-MCF with 5 cartridge is provided before ultra filtration (UF)
module as additional safety for ultra filtration from suspended particles.
Ultra Fil trat ion module (UF):-UF system is a membrane separation process. UF employs a cross
flow path of water across a membrane where the purified water and the reject are separated out
continuously. The reject water containing the separated bacteria is continuously drained and henceavoiding the accumulation of bacteria.
8/10/2019 Purified Water Generetion System Operation1
8/13
pH Dosing
(NaOH)
1102
Anti Scalent
Dosing 1103SMBS
Dosing 1104
FROM UF PRODUCT
STORAGE TANK 1101M
C
F
PG
AUTO
DUMPVALVE
SP SP
MCF DOSING SECTION
BUFFER
TANK 2101
pH Correct ion Dosing :-Provided to maintain the quantity of permeates. An alkaline pH also ensures the removal of
dissolved CO2from the system during desalination.
Ant i Scalent Dosing:-The salt during desalination tends to deposit on membrane surface thus affecting the
performance of RO system. To avoid deposition of salts on RO membranes Anti Scalent dosing is provided which
reduces salt deposition on RO membranes and increases the cleaning duration.
Micro n Cartrid ge Filter (MCF):-High suspended particles in water may choke membrane passage and may also
damage the membranes thus affecting performance and life of RO system. 5 Cartridge filter removes the suspended
particles from the feed water.
Sodium Meta Bi Sulphate Dosing;-The free chlorine in feed water is injurious for RO Polyamide membranes and is
removed from water by SMBS Dosing.
8/10/2019 Purified Water Generetion System Operation1
9/13
FROM
BUFFER
TANK
H.P.P
FI
FI
FI
REVERSE OSMOSIS (RO) IN SERVICE
FEED PT
AUTO
VALVE
TO BT
REJ PT
REJVALVE
FEED
PRODUCT
RECYCLE
MEMBRANE MEMBRANE
MEMBRANE MEMBRANE
PARTIALLY
OPEN
Reverse Osmos is:-A process which removesthe dissolved salt molecules & metallic ions from
water by forcing it through polyamide semi-
permeable membrane by operating the system
above the osmotic pressure and each membrane
is designed for NaCl salt rejection by 95- 97%.
The pretreated water is passed through RO
Module for Primary Salt Reduction from Water.
8/10/2019 Purified Water Generetion System Operation1
10/13
ROPROD.
DILUATE
INLET
CONCEN
. INLET
FI
REJECT
PRODUCT
PRODUCT
EDI UF OPERATION
EDIUV LAMPS 2101
Electro De Ion ization (EDI):-The permeate water from RO system is further to be treated
by passing through resin bed for removal of dissolved salt (approx < 5ppm) and to bring down the
overall conductivity
8/10/2019 Purified Water Generetion System Operation1
11/13
DISTRIBUTION PUMP
3101
EDI PRODUCT
The purified water generated is stored in Purified Water Storage Tank.
PURIFIED WATER
STORAGE TANK
8/10/2019 Purified Water Generetion System Operation1
12/13
UV LAMAPS
USER POINTSFROM PURIFIEDWATER TANK
Purified water from the storage tank is distributed
through closed loop to user points. Each user point is
designed with zero dead diaphragm valves to keep
the loop in circulation.
A UV is provided in the supply loop to check the
microbial in the supply loop.
On line TOC (Total Organic Carbon) analyzer with
transmitter is also provided.
TO
PURIFIEDWATER
STORAGE
TANK
TOC