4
Stg Rev Description Date Int. App SK A 01 02 ISSUED TO CLIENT FOR INFORMATION ISSUED FOR APPROVAL 13/09/2016 12/05/2017 MG LMD LD LMD MINOR WORKS - PUNCHBOWL PRIMARY SCHOOL DEPARTMENT OF EDUCATION GENERAL NOTES : L . M . DELL ACC . No . CC 5932 G Level 2, 73 Paterson street, Launceston Tas 7250. P.O Box 378 Tel - 633 89914 - Mob - 0400 655 771 Email - [email protected] IN ACCORDANCE WITH THE N.C.C.S BUILDING CODE OF AUSTRALIA VOLUME TWO, ALL BUILDING WORK SHALL BE IN STRICT COMPLIANCE WITH COUNCIL LAWS, REFERENCED AUSTRALIAN STANDARDS, BUILDING ACTS & REGULATIONS REFER ALSO TO THE GENERAL REQUIREMENTS PAGE. SITE CLASSIFICATION : DESIGN WIND SPEED CLIMATE ZONE: SCALE @ A3 12/05/2017 DRAWING No: PRINT DATE: PROJECT NUMBER: SCALE: IF IN DOUBT ASK 7 N2 N/A ALL DRAWINGS SHALL BE READ IN CONJUNCTION WITH THE ENGINEERING DRAWINGS AND SPECIFICATIONS. THE DESIGNER SHALL BE NOTIFIED OF ANY DISCREPANCIES WITH THE DRAWINGS. THE BUILDER SHALL BE RESPONSIBLE FOR THE CORRECT SETOUT OF ALL WORKS. A LAND SURVEYOR IS RECCOMENDED BY THE DESIGNER FOR ALL SETOUT. USE FIGURED DIMENSIONS IN PREFERENCE TO SCALED DIMENSIONS. ALL FITTINGS & FIXTURES INSTALLED SHALL BE PURCHASED AS NEW CONDITION & QUALITY & CARRY THE RELEVANT AUSTRALIAN STANDARD COMPLIANCES. THE BUILDER SHALL CARRY OUT DIAL BEFORE YOU DIG REFERRAL FOR LOCATIONS OF ALL UNDERGROUND SERVICES PRIOR TO COMMENCING ANY EARTHWORKS. THE BUILDER SHALL SECURE AND MAKE SAFE THE WORKSITE IN ACCORDANCE WITH WORK SAFE TASMANIA & WHS GUIDELINES & REGULATIONS. THE BUILDER SHALL INSTALL SILT TRAPS & SCREENS AT THE PROPERTY BOUNDARY TO PREVENT SILT RUNOFF INTO THE COUNCIL MAIN SYSTEM FOR THE DURATION OF SITE WORKS. 161111 BUSHFIRE ATTACK LEVEL: BAL N/A ALPINE AREA: N/A PROJECT INFORMATION: WIND REGION: A3 TERRAIN CLASSIFICATION: T2 FLOOR FLOOR AREAS: DECK & SEATING AREA - 136 m 2 LAND TITLE, VOLUME & FOLIO ID 6887570 A000-A02 PUNCHBOWL PRIMARY SCHOOL 146 PUNCHBOWL RD NEWSTEAD TAS 7250 PROPERTY ID - 6887570 North LOCATION PLAN SCALE 1:1000 0mm 10000 20000 30000 40000 50000

PUNCHBOWL PRIMARY GENERAL NOTES: IN ... COUNCIL MAIN SYSTEM FOR THE DURATION OF SITE WORKS. 161111 BUSHFIRE ATTACK LEVEL: BAL N/A ALPINE AREA: N/A PROJECT INFORMATION: WIND REGION:

Embed Size (px)

Citation preview

Page 1: PUNCHBOWL PRIMARY GENERAL NOTES: IN ... COUNCIL MAIN SYSTEM FOR THE DURATION OF SITE WORKS. 161111 BUSHFIRE ATTACK LEVEL: BAL N/A ALPINE AREA: N/A PROJECT INFORMATION: WIND REGION:

Stg Rev Description Date Int. AppSK

A

01

02

ISSUED TO CLIENT FOR INFORMATION

ISSUED FOR APPROVAL

13/09/2016

12/05/2017

MG

LMD

LD

LMD

MINOR WORKS - PUNCHBOWL PRIMARY SCHOOLDEPARTMENT OF EDUCATION

GENERAL NOTES:

L .M.DELL ACC. No. CC5932 GLevel 2, 73 Paterson street, Launceston Tas7250. P.O Box 378Tel - 633 89914 - Mob - 0400 655 771Email - [email protected]

IN ACCORDANCE WITH THE N.C.C.S BUILDING CODE OFAUSTRALIA VOLUME TWO, ALL BUILDING WORK SHALL BEIN STRICT COMPLIANCE WITH COUNCIL LAWS,REFERENCED AUSTRALIAN STANDARDS, BUILDING ACTS &REGULATIONS REFER ALSO TO THE GENERALREQUIREMENTS PAGE.

SITE CLASSIFICATION :

DESIGN WIND SPEED

CLIMATE ZONE:

SCALE @ A3 12/05/2017DRAWING No:PRINT DATE:PROJECT NUMBER: SCALE: IF IN DOUBT ASK

7

N2

N/A

ALL DRAWINGS SHALL BE READ IN CONJUNCTION WITHTHE ENGINEERING DRAWINGS AND SPECIFICATIONS.THE DESIGNER SHALL BE NOTIFIED OF ANYDISCREPANCIES WITH THE DRAWINGS.

THE BUILDER SHALL BE RESPONSIBLE FOR THE CORRECTSETOUT OF ALL WORKS. A LAND SURVEYOR ISRECCOMENDED BY THE DESIGNER FOR ALL SETOUT.USE FIGURED DIMENSIONS IN PREFERENCE TO SCALEDDIMENSIONS.

ALL FITTINGS & FIXTURES INSTALLED SHALL BEPURCHASED AS NEW CONDITION & QUALITY & CARRYTHE RELEVANT AUSTRALIAN STANDARD COMPLIANCES.

THE BUILDER SHALL CARRY OUT DIAL BEFORE YOU DIGREFERRAL FOR LOCATIONS OF ALL UNDERGROUNDSERVICES PRIOR TO COMMENCING ANY EARTHWORKS.

THE BUILDER SHALL SECURE AND MAKE SAFE THEWORKSITE IN ACCORDANCE WITH WORK SAFETASMANIA & WHS GUIDELINES & REGULATIONS.

THE BUILDER SHALL INSTALL SILT TRAPS & SCREENS AT THEPROPERTY BOUNDARY TO PREVENT SILT RUNOFF INTOTHE COUNCIL MAIN SYSTEM FOR THE DURATION OF SITEWORKS.

161111

BUSHFIRE ATTACK LEVEL:

BAL N/AALPINE AREA:

N/A

PROJECT INFORMATION:

WIND REGION:

A3TERRAIN CLASSIFICATION:

T2

FLOOR FLOOR AREAS:

DECK & SEATING AREA - 136 m2

LAND TITLE, VOLUME & FOLIO

ID 6887570

A000-A02

PUNCHBOWL PRIMARYSCHOOL146 PUNCHBOWL RDNEWSTEAD TAS 7250PROPERTY ID - 6887570

North

LOCATION PLANSCALE 1:1000

0mm 10000 20000 30000 40000 50000

croweg
Stamp
Page 2: PUNCHBOWL PRIMARY GENERAL NOTES: IN ... COUNCIL MAIN SYSTEM FOR THE DURATION OF SITE WORKS. 161111 BUSHFIRE ATTACK LEVEL: BAL N/A ALPINE AREA: N/A PROJECT INFORMATION: WIND REGION:

Stg Rev Description Date Int. AppSK

SK

SK

A

01

02

03

04

ISSUED TO CLIENT FOR INFORMATION

ISSUED FOR INFORMATION

ISSUED FOR INFORMATION

ISSUED FOR APPROVAL

13/09/2016

26/09/2016

30/09/2016

12/05/2017

MG

MG

MG

LMD

LD

LD

LD

LMD

MINOR WORKS - PUNCHBOWL PRIMARY SCHOOLDEPARTMENT OF EDUCATION

GENERAL NOTES:

L .M.DELL ACC. No. CC5932 GLevel 2, 73 Paterson street, Launceston Tas7250. P.O Box 378Tel - 633 89914 - Mob - 0400 655 771Email - [email protected]

IN ACCORDANCE WITH THE N.C.C.S BUILDING CODE OFAUSTRALIA VOLUME TWO, ALL BUILDING WORK SHALL BEIN STRICT COMPLIANCE WITH COUNCIL LAWS,REFERENCED AUSTRALIAN STANDARDS, BUILDING ACTS &REGULATIONS REFER ALSO TO THE GENERALREQUIREMENTS PAGE.

SITE CLASSIFICATION :

DESIGN WIND SPEED

CLIMATE ZONE:

SCALE @ A3 12/05/2017DRAWING No:PRINT DATE:PROJECT NUMBER: SCALE: IF IN DOUBT ASK

7

N2

N/A

ALL DRAWINGS SHALL BE READ IN CONJUNCTION WITHTHE ENGINEERING DRAWINGS AND SPECIFICATIONS.THE DESIGNER SHALL BE NOTIFIED OF ANYDISCREPANCIES WITH THE DRAWINGS.

THE BUILDER SHALL BE RESPONSIBLE FOR THE CORRECTSETOUT OF ALL WORKS. A LAND SURVEYOR ISRECCOMENDED BY THE DESIGNER FOR ALL SETOUT.USE FIGURED DIMENSIONS IN PREFERENCE TO SCALEDDIMENSIONS.

ALL FITTINGS & FIXTURES INSTALLED SHALL BEPURCHASED AS NEW CONDITION & QUALITY & CARRYTHE RELEVANT AUSTRALIAN STANDARD COMPLIANCES.

THE BUILDER SHALL CARRY OUT DIAL BEFORE YOU DIGREFERRAL FOR LOCATIONS OF ALL UNDERGROUNDSERVICES PRIOR TO COMMENCING ANY EARTHWORKS.

THE BUILDER SHALL SECURE AND MAKE SAFE THEWORKSITE IN ACCORDANCE WITH WORK SAFETASMANIA & WHS GUIDELINES & REGULATIONS.

THE BUILDER SHALL INSTALL SILT TRAPS & SCREENS AT THEPROPERTY BOUNDARY TO PREVENT SILT RUNOFF INTOTHE COUNCIL MAIN SYSTEM FOR THE DURATION OF SITEWORKS.

161111

BUSHFIRE ATTACK LEVEL:

BAL N/AALPINE AREA:

N/A

PROJECT INFORMATION:

WIND REGION:

A3TERRAIN CLASSIFICATION:

T2

FLOOR FLOOR AREAS:

DECK & SEATING AREA - 136 m2

LAND TITLE, VOLUME & FOLIO

ID 6887570

A121-A04

4,50011,410

15,910

4,50011,455

9,54

5

3,00

01,

000

1,00

01,

000

1,00

01,

000

RL +540

RL- 0.0 GRASS OVAL

+300

+600

+900

+1200

+1500

+1800

RL +540

AA2100

AA2100

BA2100

BA2100

3A2100

EXISTING FENCE LINE

EXIS

TIN

G W

IRE

MES

H F

ENCE

LIN

E

EX.GARDENBED

EX.GARDENBED

EX. GARDEN BED

NEW ROOF EXTENSION TOMATCH EX. BUILDING 4 ROOF

NEWGARDENBED

DECK

BALUSTRADE

TIERED SEATING AREA

WALKWAY & EXTERNAL DECK

NEW UNDER DECKACCESS GATE

NEW Col.

EX. ROOF LINE

BUILDING 4EARLY CHILDHOOD LEARNING

STORAGESPACEBELOW

EX.RETAININGWALL

NEW Col.

REPLACE WITH NEW DECKING 52m2EXISTINGSTAIRS

EX. H

AND

RAIL

EXISTING FENCE LINENEWCol.

NEWCol.

STAI

R

HAN

DRA

IL

HAN

DRA

IL

HAN

DRA

IL

TIER 06

TIER 04

TIER 03

TIER 02

TIER 01

BALU

STRA

DE

TIM

BER

LAN

DIN

GTO

MAT

CH R

AMP

LAN

DIN

G

GARDEN BED

NEW TIMBER ORCONCRETE STEPS

NOT COVERED

NEWCol.

NEW ROOF EXTENSION TOMATCH EX. BUILDING 4 ROOF NEW

Col.

NEW Col.

NEW Col.

EX HARDSTAND PLAYCOURTS

EX. RAMP

EX. RAMP

EX. R

AMP

EX. RAMP

DEMOLISH EXISTING TIERED DECK AREA

DEMOLISH EXISTING BLDG 4 DECKING

EX GRAVELEX RAMP

EX L

AND

ING

EX RAMP

EX R

AMP

EX RAMP

LINE OF EX ROOF

EX. G

ARDE

N BE

D

EX. GARDEN BED

RETAIN EXISTING ROOF

EXISTING HARDCOURTS

EXISTING OVAL

Project North

DECK - GROUND FLOOR PLANSCALE 1:100

0mm 1000 2000 3000 4000 5000

North

DECK GROUND FLOOR DEMOLITION PLANSCALE 1:100

0mm 1000 2000 3000 4000 5000

croweg
Stamp
Page 3: PUNCHBOWL PRIMARY GENERAL NOTES: IN ... COUNCIL MAIN SYSTEM FOR THE DURATION OF SITE WORKS. 161111 BUSHFIRE ATTACK LEVEL: BAL N/A ALPINE AREA: N/A PROJECT INFORMATION: WIND REGION:

Stg Rev Description Date Int. AppA 01 ISSUED FOR APPROVAL 12/05/2017 LMD LMD

MINOR WORKS - PUNCHBOWL PRIMARY SCHOOLDEPARTMENT OF EDUCATION

GENERAL NOTES:

L .M.DELL ACC. No. CC5932 GLevel 2, 73 Paterson street, Launceston Tas7250. P.O Box 378Tel - 633 89914 - Mob - 0400 655 771Email - [email protected]

IN ACCORDANCE WITH THE N.C.C.S BUILDING CODE OFAUSTRALIA VOLUME TWO, ALL BUILDING WORK SHALL BEIN STRICT COMPLIANCE WITH COUNCIL LAWS,REFERENCED AUSTRALIAN STANDARDS, BUILDING ACTS &REGULATIONS REFER ALSO TO THE GENERALREQUIREMENTS PAGE.

SITE CLASSIFICATION :

DESIGN WIND SPEED

CLIMATE ZONE:

SCALE @ A3 12/05/2017DRAWING No:PRINT DATE:PROJECT NUMBER: SCALE: IF IN DOUBT ASK

7

N2

N/A

ALL DRAWINGS SHALL BE READ IN CONJUNCTION WITHTHE ENGINEERING DRAWINGS AND SPECIFICATIONS.THE DESIGNER SHALL BE NOTIFIED OF ANYDISCREPANCIES WITH THE DRAWINGS.

THE BUILDER SHALL BE RESPONSIBLE FOR THE CORRECTSETOUT OF ALL WORKS. A LAND SURVEYOR ISRECCOMENDED BY THE DESIGNER FOR ALL SETOUT.USE FIGURED DIMENSIONS IN PREFERENCE TO SCALEDDIMENSIONS.

ALL FITTINGS & FIXTURES INSTALLED SHALL BEPURCHASED AS NEW CONDITION & QUALITY & CARRYTHE RELEVANT AUSTRALIAN STANDARD COMPLIANCES.

THE BUILDER SHALL CARRY OUT DIAL BEFORE YOU DIGREFERRAL FOR LOCATIONS OF ALL UNDERGROUNDSERVICES PRIOR TO COMMENCING ANY EARTHWORKS.

THE BUILDER SHALL SECURE AND MAKE SAFE THEWORKSITE IN ACCORDANCE WITH WORK SAFETASMANIA & WHS GUIDELINES & REGULATIONS.

THE BUILDER SHALL INSTALL SILT TRAPS & SCREENS AT THEPROPERTY BOUNDARY TO PREVENT SILT RUNOFF INTOTHE COUNCIL MAIN SYSTEM FOR THE DURATION OF SITEWORKS.

161111

BUSHFIRE ATTACK LEVEL:

BAL N/AALPINE AREA:

N/A

PROJECT INFORMATION:

WIND REGION:

A3TERRAIN CLASSIFICATION:

T2

FLOOR FLOOR AREAS:

DECK & SEATING AREA - 136 m2

LAND TITLE, VOLUME & FOLIO

ID 6887570

A2100-A01

+4,200

-1,800

1,80

04,

200

6,00

0

±0

EX. ROOF HT

GROUND LEVEL

GROUND FLOOR

TABLE BY OTHERSNEW STEEL AND TREATED PINEFRAMED DECKING AND TIEREDSEATING.

EXPLAYCOURTS

EXISTING GROUND LINE VARIES.

EXISTING SPORTS OVAL

EX RAMP

EX F

ENCE

NEW STEEL SUPPORTSTRUCTURE.

-1,819

1,81

91,

000

±0

+1,000

+3,000EX. ROOF HT

OVAL LEVEL

GROUND FLOOR

BALUSTRADE HT

NEW ROOF OVER DECK

BALUSTRADE

COLORBONDCLADDING

NEW STAIRSAND HANDRAILAND LANDING

1m HIGH BALUSTRADETO MATCH EXISTING.

STEEL FRAMED ROOF STRUCTURE.METAL DECK ROOF SHEETING TOMATCH EXISTING.

NEW STEEL AND TREATED PINEFRAMED DECKING AND TIEREDSEATING.

EX RAMP.

+2,700

-1,819

±0

+1,000

+2,100

(240

0 M

IN)

WINDOW HT

OVAL LEVEL

GROUND FLOOR

BALUSTRADE HT

EX.WINDOW

EX.WINDOW

EX.WINDOW

DOOR HT

NEW ROOF

TABLE BY OTHERS

NEW COVEREDDECK

NEW STEEL AND TREATED PINEFRAMED DECKING AND TIEREDSEATING.

EXISTING SPORTS OVAL

EXPLAYCOURTS

EX F

ENCE

EXISTINGTERRAPIN

ROOFRETAINED

NEW WALKWAY ROOFTO MATCH EXISTING

EXISTINGROOF RETAINED

NEW ROOFOVER NEW DECK

EAVE

S GU

TTER

D.P. EAVES GUTTER

NEW METAL DECK ROOFSHEETING TO MATCH EXISTING.

1-

A SECTION AASCALE 1:100

0mm 1000 2000 3000 4000 5000

3-

E01 ELEVATIONSCALE 1:100

0mm 1000 2000 3000 4000 5000

2-

B SECTION BBSCALE 1:100

0mm 1000 2000 3000 4000 5000

4A122

ROOF PLANSCALE 1:100

0mm 1000 2000 3000 4000 5000

croweg
Stamp
Page 4: PUNCHBOWL PRIMARY GENERAL NOTES: IN ... COUNCIL MAIN SYSTEM FOR THE DURATION OF SITE WORKS. 161111 BUSHFIRE ATTACK LEVEL: BAL N/A ALPINE AREA: N/A PROJECT INFORMATION: WIND REGION:

Stg Rev Description Date Int. AppSK

A

01

02

ISSUED TO CLIENT FOR INFORMATION

ISSUED FOR APPROVAL

13/09/2016

12/05/2017

MG

LMD

LD

LMD

MINOR WORKS - PUNCHBOWL PRIMARY SCHOOLDEPARTMENT OF EDUCATION

GENERAL NOTES:

L .M.DELL ACC. No. CC5932 GLevel 2, 73 Paterson street, Launceston Tas7250. P.O Box 378Tel - 633 89914 - Mob - 0400 655 771Email - [email protected]

IN ACCORDANCE WITH THE N.C.C.S BUILDING CODE OFAUSTRALIA VOLUME TWO, ALL BUILDING WORK SHALL BEIN STRICT COMPLIANCE WITH COUNCIL LAWS,REFERENCED AUSTRALIAN STANDARDS, BUILDING ACTS &REGULATIONS REFER ALSO TO THE GENERALREQUIREMENTS PAGE.

SITE CLASSIFICATION :

DESIGN WIND SPEED

CLIMATE ZONE:

SCALE @ A3 12/05/2017DRAWING No:PRINT DATE:PROJECT NUMBER: SCALE: IF IN DOUBT ASK

7

N2

N/A

ALL DRAWINGS SHALL BE READ IN CONJUNCTION WITHTHE ENGINEERING DRAWINGS AND SPECIFICATIONS.THE DESIGNER SHALL BE NOTIFIED OF ANYDISCREPANCIES WITH THE DRAWINGS.

THE BUILDER SHALL BE RESPONSIBLE FOR THE CORRECTSETOUT OF ALL WORKS. A LAND SURVEYOR ISRECCOMENDED BY THE DESIGNER FOR ALL SETOUT.USE FIGURED DIMENSIONS IN PREFERENCE TO SCALEDDIMENSIONS.

ALL FITTINGS & FIXTURES INSTALLED SHALL BEPURCHASED AS NEW CONDITION & QUALITY & CARRYTHE RELEVANT AUSTRALIAN STANDARD COMPLIANCES.

THE BUILDER SHALL CARRY OUT DIAL BEFORE YOU DIGREFERRAL FOR LOCATIONS OF ALL UNDERGROUNDSERVICES PRIOR TO COMMENCING ANY EARTHWORKS.

THE BUILDER SHALL SECURE AND MAKE SAFE THEWORKSITE IN ACCORDANCE WITH WORK SAFETASMANIA & WHS GUIDELINES & REGULATIONS.

THE BUILDER SHALL INSTALL SILT TRAPS & SCREENS AT THEPROPERTY BOUNDARY TO PREVENT SILT RUNOFF INTOTHE COUNCIL MAIN SYSTEM FOR THE DURATION OF SITEWORKS.

161111

BUSHFIRE ATTACK LEVEL:

BAL N/AALPINE AREA:

N/A

PROJECT INFORMATION:

WIND REGION:

A3TERRAIN CLASSIFICATION:

T2

FLOOR FLOOR AREAS:

DECK & SEATING AREA - 136 m2

LAND TITLE, VOLUME & FOLIO

ID 6887570

A001-A02

AREA OF WORKS

BUILDING 3CLASSROOMS

BUILDING 1ADMIN, RECEPTION LIBRARY& CLASS ROOMS

ENTRY TORECEPTION

BUILDING 5GENERAL PURPOSE HALL

STAFF CARPARK

BUILDING 6CLASSROOMS

EXISTING DECKING&

TIERED SEATING

EXISTINGHARDSTANDPLAY COURTS

EX. RAMP

EXISTING SPORTS OVAL

EX. BUILDING 1AMENITIES

(REFURBISHED INTERNALLY)

BUILDING 4

EXISTING UNDERCOVER WALKWAY

EXISTING WIRE MESH FENCING 3.0m (H)

EX. RAMP

EX ASPHALT RAMP

EX. GRASSED AREA

EX RETAINING WALL

EX. ASPHALT EX. BLDG 4 DECKING

EXISTINGCOVEREDWALKWAY

SCOPE OF WORKSBUILDING 4 DECK & OVAL TIERED SEATINGREMOVAL OF EXISTING OVAL TIERED DECK SEATING& DECKING, INSTALL NEW BUILDING 4 DECKING, &ROOF OVER. INSTALELD NEW TIERED SHEETINGAND ACCESS STAIRS.

Project North

SITE PLANSCALE 1:300

0mm 3000 6000 9000 12000 15000

EXISTING CONDITIONS PHOTO

EXISTING CONDITIONS PHOTO

croweg
Stamp