34
PSX-100 24-bit 2-channel 44.1–96kHz High Density A/D-D/A Conversion System Operating Manual and UV22 ® License Agreement Version 3b — July 2000 Firmware v 3.0.0 – inc. Single-Wire

PSX Manual v3 - Apogee Electronics - Audio Interfaces … · Operating Manual and UV22 ... This device must accept any interference received, including interference that may cause

Embed Size (px)

Citation preview

PPSSXX--11000024-bit 2-channel

44.1–96kHz High DensityA/D-D/A Conversion System

Operating Manual andUV22® License Agreement

Version 3b — July 2000Firmware v 3.0.0 – inc. Single-Wire

Manual written by Doug Bell.Edited by Julio Alvarez & Joe Raia. Interconnection diagrams by Julio Alvarez.Many thanks to Roger and Brigitte Robindoré for their exhaustive proffreadign.Produced, edited and generally mangled for production by Richard Elen.

SoftLimit and UV22 are Registered Trademarks of Apogee Electronics Corporation. All other trademarks areproperty of their respective holders.Technology within the PSX-100, including the Low Jitter Clock, may be covered by one or more patents that arethe property of Apogee Electronics Corporation. Infringement of said patents may result in a plague of rhinosbeing visited upon your firstborn, and/or other more conventional measures.

Registered User Customer Support:Please call (310) 915-1000 and ask for Tech Support, or email [email protected] unit should be registered to receive technical support.

Features and specifications subject to change without notice.

APOGEE ELECTRONICS CORPORATION3145 Donald Douglas Loop SouthSanta Monica, California 90405-3210 USATel: +1 310/915-1000Fax: +1 310/391-6262Email: [email protected]: http://www.apogeedigital.com/This manual is copyright ©1999 by APOGEE ELECTRONICS CORPORATION. All rights reserved. Under copy-right laws, this manual may not be duplicated in whole or in part without the written consent of Apogee.

PSX-100 User’s Manual

PSX-100 User’s Manual

PPSSXX--11000024-bit 2-channel

44.1–96kHz High DensityA/D-D/A Conversion System

Operating Manual andUV22® License Agreement

Version 3b — July 2000Firmware v 3.0.0 – inc. Single-Wire

WarningsCAUTION: To reduce the risk of electrical shock, do not remove the cover. No user serviceable parts inside;

refer servicing to qualified personnel. To change the operating voltage and install the video option card, it isnecessary to remove the cover of the unit. As a result, such operations must be carried out only by technically-qualified personnel.

WARNING: To reduce the risk of fire or electrical shock, do not expose this appliance to rain or moisture.

This symbol, wherever it appears, alerts you to the presence of uninsulated dangerous voltage insidethe enclosure—voltage that may be sufficient to constitute a risk of shock. Operations indicated withthis symbol should be carried out only by technically-qualified personnel.

This symbol, wherever it appears, alerts you to important operating and maintenance instructions inthe accompanying literature. Read the manual.

Environmental warnings• Never touch the AC plug with wet hands.• Do not use this unit in damp areas or near water.• Avoid damaging the AC plug or cord and potentially causing a shock hazard.• If liquids spill into or onto the PSX-100, disconnect the power and return to your dealer for servicing.• This unit should only be connected to an AC power supply of the correct voltage. Check with your dealer

if in doubt.• Precautions should be taken so that the grounding or polarization of the AC power is not defeated.• Unplug the AC cord when the unit is unused for long periods of time.• This unit should only be cleaned as recommended by the manufacturer, or damage to the finish may result.• To avoid potential damage to your unit, only use in areas where proper ventilation and moderate tempera-

tures are assured.

Power warningAC voltage ratings for electrical power vary from area to area. Severe damage to your unit is possibleif your PSX-100 is configured incorrectly for your local power. If in doubt, consult an Apogee dealer. Alabel adjacent to the power connector indicates the voltage to which the unit was set on leaving thefactory.

Instructions for changing the power input voltage are provided. We strongly advise you to check thatthe voltage label remains current and is updated if the input voltage setting is changed.

FCC warningThis equipment has been tested and found to comply with the limits for a Class A digital device, pur-suant to Part 15 of the FCC rules. These limits are designed to provide reasonable protection againstharmful interference when operated in a commercial environment. This equipment generates, uses,

and can radiate radio frequency energy and, if not installed and used in accordance with the instruction manu-al, may cause harmful interference to radio communications. Operation of this equipment in a residential areais likely to cause harmful interference, in which case the user will be required to take whatever measures maybe required to correct the interference at his own expense.

Copyright NoticeThe Apogee PSX-100 is a computer-based device, and as such contains and uses software in ROMs. This

software, and all related documentation, including this Owner’s Manual, contain proprietary information whichis protected by copyright laws. All rights are reserved. No part of the software and its related documentationmay be copied, transferred, or modified. You may not modify, adapt, translate, lease, distribute, resell for prof-it or create derivative works based on the software and its related documentation or any part thereof withoutprior written consent from Apogee Electronics Corporation, U.S.A.

PSX-100 User’s Manual

Page 4

Registration and Warranty InformationBe sure to register your PSX-100, either by filling in the enclosed Registration Card orby completing our on-line registration form at our Web site: http://www.apogeedigi-tal.com/register.html. If you do so, Apogee can contact you with any update information. Asenhancements and upgrades are developed, you will be contacted at the registrationaddress. Firmware updates are free for the first year of ownership. Please address anyinquiries to your dealer or directly to Apogee at:

APOGEE ELECTRONICS CORPORATION, 3145 Donald Douglas Loop South, Santa Monica, CA 90405, USA. TEL: (310) 915-1000, FAX: (310) 391-6262

email: [email protected]. Web: http://www.apogeedigital.com/

APOGEE ELECTRONICS CORPORATION warrants this product to be free of defects in material and manufac-ture under normal use for a period of 12 months. The term of this warranty begins on the date of sale to thepurchaser. Units returned for warranty repair to Apogee or an authorized Apogee warranty repair facility will berepaired or replaced at the manufacturer’s option, free of charge. All units returned to Apogee or an autho-rized Apogee repair facility must be prepaid, insured and properly packaged. Apogee reserves the right tochange or improve design at any time without prior notice. Design changes are not implemented retrospec-tively, and the incorporation of design changes into future units does not imply the availability of an upgradeto existing units.

This warranty is void if Apogee determines, in its sole business judgment, the defect to be the result of abuse,neglect, alteration or attempted repair by unauthorized personnel.

The warranties set forth above are in lieu of all other warranties, expressed or implied, and Apogee specifical-ly disclaims any and all implied warranty of merchantability or of fitness for a particular purpose. The buyeracknowledges and agrees that in no event shall the company be held liable for any special, indirect, incidentalor consequential damages, or for injury, loss or damage sustained by any person or property, that may resultfrom this product failing to operate correctly at any time.

USA: Some states do not allow for the exclusion or limitation of implied warranties or liability for incidental orconsequential damage, so the above exclusion may not apply to you. This warranty gives you specific legalrights, and you may have other rights which vary from state to state.

Service Information

If the PSX-100 is kept in a clean environment free of excess dust, moisture and heat, it will give years of trou-ble-free service.

The PSX-100 contains no user-serviceable components: refer to qualified service personnel for repair orupgrade. Your warranty will be voided if you tamper with the internal components. If you have any questionswith regard to the above, please contact Apogee by phone at (310) 915-1000, by fax at (310) 391-6262, or viaemail to [email protected].

In the event your PSX-100 needs to be upgraded or repaired, it is necessary to contact Apogee prior to ship-ping, and a Return Materials Authorization (RMA) number will be assigned. This number will serve as a refer-ence for you and helps facilitate and expedite the return process. Apogee requires that shipments be pre-paidand insured — unless otherwise authorized in advance. IMPORTANT: Any shipment that is not pre-paid or issent without an RMA number will not be accepted.

PSX-100 User’s Manual

Page 5

Declarations of Conformity

Declaration of Conformity—FCC

Apogee PSX-100

This device complies with Part 15 of the FCC Rules. Operation is subject to the following two conditions:(1) This device may not cause harmful interference, and(2) This device must accept any interference received, including interference that may cause undesired opera-tion.

This equipment has been tested and found to comply with the limits of a Class B digital device, pursuant toPart 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful intefer-ence in a residential installation. This equipment generates, uses and can radiate radio frequency energy and,if not installed and used in accordance with the instructions, may cause harmful interference to radio commu-nications. If this equipment does cause harmful interference to radio or television reception, which can be deter-mined by turning the equipment off and on, the user is encouraged to try to correct the interference by one ormore of the following measures:1. Re-orient or relocate the receiving antenna.2. Increase the separation between the equipment and receiver.3. Connect the equipment into an outlet on a different circuit from that to which the receiver is connected.4. Consult the dealer or an experienced radio/TV technician for help.NOTE: The use of non-shielded cable with this equipment is prohibited.CAUTION: Changes or modifications not expressly approved by the manufacturer responsible for compliancecould void the user’s authority to operate the equipment.

Apogee Electronics Corporation, 3145 Donald Douglas Loop South, Santa Monica, CA 90405. Edward Pendyk, VP Engineering.

Industry Canada Notice

This Class B digital apparatus meets all requirements of the Canadian Interference-Causing EquipmentRegulations.

Cet appareil numérique de la classe B respecte toutes les exigences du Règlement sur le matérial brouilleurdu Canada.

Declaration of Conformity – CE

Apogee Electronics Corporation hereby declares that the product, the PSX-100 system, to which this declara-tion relates, is in material conformity with the following standards or other normative documents:• EN50081-1/EN55022; 1995• EN50082-1/IEC 801-2, 3, 4; 1992following the provisions of:• 73/23/EEC – Low Voltage Directive• 89/336/EEC – EMC Directive

Declaration of Conformity – Japan

Apogee Electronics Corporation hereby declares that the PSX-100 system, to which this declaration relates, isin material conformity with the VCCI Class A standard.

Declaration of Conformity – Australia

Apogee Electronics Corporation hereby declares that the PSX-100 system is in material conformity withAN/NZS standard requirements.

PSX-100 User’s Manual

Page 6

Licensing and Legal Information

Carefully read the following legal agreement prior to using the UV22HR process provided in the PSX-100.Use of UV22HR constitutes your acceptance of these terms. If you do not agree to the terms of the agreement,promptly return the PSX-100 and the accompanying items, including written materials and containers to thelocation where you obtained them for a full refund.

1. License Grant APOGEE ELECTRONICS CORPORATION (“Apogee”) hereby grants to you, the Purchaser(either as an individual or entity), a personal, non-transferable, and non-exclusive right to use the UV22HRProcess provided with this license. You agree you will not copy the materials accompanying the PSX-100. Thematerial contained in this manual consists of information that is the property of Apogee and is intended solelyfor use by the purchasers of the equipment described in this manual. Apogee expressly prohibits the duplica-tion of any portion of this manual or the use thereof for any purpose other than the operation or maintenanceof the equipment described in this manual without the express written permission of Apogee.

2. Copyright You acknowledge that no title to the intellectual property in the PSX-100 is transferred to you.You further acknowledge that title and full ownership rights to the PSX-100 will remain the exclusive propertyof Apogee, and you will not acquire any rights to the UV22HR process except as expressly set forth above.

3. Reverse Engineering You agree that you will not attempt (and, if you are a corporation, you agree to useyour best efforts to prevent your employees and contractors from attempting) to reverse compile, modify,translate or disassemble the UV22HR Process Software in whole or in part.

4. Customer Remedies Apogee’s entire liability and your sole and exclusive remedy shall be, at Apogee’soption, either to (a) correct the error, (b) help you work around or avoid the error or (c) authorize a refund orreplacement (at Apogee’s option), so long as the PSX-100, documentation and all accompanying items arereturned to Apogee according to the instructions on the Warranty Information page opposite, with a copy ofyour receipts.

CAUTIONAny changes or modifications not expressly approved by APOGEE ELECTRONICS CORPORATION could void

your authority to operate this equipment under the FCC rules.

OWNER’S RECORD

The serial number is located on the rear of the side panel of the unit. We suggest you record the serial numberin the space provided below. Refer to it whenever you call an authorized APOGEE repair facility or the manu-facturer. Make sure that you return your completed warranty card immediately!

Model No. PSX-100 Serial No. ________________ Purchase Date __________________

Factory Firmware Revision ________________

Dealer____________________________________________________

Phone ____________________________________________________

Address ___________________________________________________

PSX-100 User’s Manual

Page 7

User’s Installation Notes

Space left blank for user tracking of factory modifications, option installations, software upgrades, manual revi-sions/ addenda, internal settings.

About This ManualThis manual was written for you, the user, to use this product to its fullest potential. The PSX-100 contains manyfeatures that may not be obvious from the front panel. Therefore, reading this manual is necessary to unlockthe full value of this product.

This manual was also written to prevent misuse of this product. Should you run into a problem when oper-ating the PSX-100, the solution is hopefully contained in the following pages. We expect that this manual willserve as the basis of your diagnosis of problems encountered and hope it will be used as such prior to any callsto technical support at Apogee.

Remember — before contacting technical support at Apogee, you must register this product either bysending in the registration card or by registering on the Apogee Web site (http://www.apogeedigital.com/). Thetechnical support specialist will almost certainly refer to the manual during your call and will expect you to haveread it and to understand the product to some degree.

If you have any suggestions on how to improve this user’s manual, please forward them [email protected] or fax them to +1-310-391-6262.

PSX-100 User’s Manual

Page 8

Table of ContentsWarnings ...........................................................................................................................4Registration & Warranty Information ...............................................................................5Service Information...........................................................................................................5Declarations of Conformity...............................................................................................6Licensing & Legal Information ..........................................................................................7Owner’s record .................................................................................................................7User’s Installation Notes ...................................................................................................8

The ManualTable of Contents..............................................................................................................9Introduction ....................................................................................................................11Features ..........................................................................................................................11Getting Started...............................................................................................................11Signal flow ......................................................................................................................12Connections ....................................................................................................................14Controls & Indicators ......................................................................................................14Buttons............................................................................................................................14

A/D SYNCOUTPUT RESOPTICAL OUTSOFT LIMABSMUTE L, RMETERDIG COPYDA INPUTMDM IN

Press & Hold Buttons......................................................................................................15A/D SYNCABSMETERD/A INPUTMDM INOUTPUT RESSOFT LIMMUTE L, RDIG COPYIndicators ...................................................................................................................16

DIP Switches ...................................................................................................................18External Settings ............................................................................................................19

Calibration Mode ............................................................................................................................................19D/A calibration................................................................................................................................................19A/D calibration................................................................................................................................................20

Using the AUX Output....................................................................................................20Internal Settings (Qualified Service Personnel Only!) ....................................................21

Voltage setting................................................................................................................................................21Fuses ...............................................................................................................................................................21Soft Limit calibration on A/D..........................................................................................................................21Common Mode Rejection adjustment on A/D ..............................................................................................21

PSX-100 User’s Manual

Page 9

DAC pin 3 hot jumpers...................................................................................................................................21Optional video card installation .....................................................................................................................21

Operational Notes ..........................................................................................................22Confidence Monitor Mode .............................................................................................................................22Digital Copy Mode..........................................................................................................................................22Analog Monitor Mode ....................................................................................................................................22ABS (Apogee Bit Splitting) Processing – Outputs .........................................................................................22ABS (Apogee Bit Splitting) Processing – Inputs.............................................................................................23

88.2/96 kHz Operation ...................................................................................................24Single-Wire 88.2/96 kHz Operation................................................................................25UV22HR Processing ........................................................................................................26Optional Video Card .......................................................................................................26Miscellaneous Features...................................................................................................26

Analog Processing ..........................................................................................................................................26Nonvolatile memory .......................................................................................................................................26Self clocking ....................................................................................................................................................26Loopback muting ............................................................................................................................................26WC out ............................................................................................................................................................26Automuting .....................................................................................................................................................27Lock timing......................................................................................................................................................27Polarity inversion.............................................................................................................................................27MDM Channel duplication..............................................................................................................................27

Error Indications .............................................................................................................27About UV22HR Super CD Encoding ...............................................................................28

UV22HR Process Application..........................................................................................................................28Application Notes ...........................................................................................................29PSX-100 Specifications....................................................................................................32

PSX-100 User’s Manual

Page 10

Introduction Overview

The PSX-100 is essentially two independent converters in one unit: a stereo 24-bit/96K analog to digital con-verter and a stereo 24-bit/96K digital to analog converter housed in a 1U rack unit. It is also a bit-splittingdevice, a format converter, and has a rich set of features as described below:

Features

• A/D and D/A can be operated and clocked independently or cross-connected in several ways• Dual Apogee Low Jitter Clocks (LJC) insure high-quality audio in any configuration• UV22HR – the mastering standard for word-length reduction – allows 16 and 20-bit outputs without signif-

icant loss of detail• Soft Limit provides maximum digital level to your recording system without overs• High-density 24-bit 88.2 and 96 kHz sampling as well as conventional 44.1 and 48 kHz rates • Metering of either A/D output or D/A input• AES/EBU, S/PDIF, ADAT and TDIF I/O• Optional video card allows sync to PAL, NTSC, or Black & White video signals• ‘Digital Copy Mode’ allows format conversion between AES/EBU, S/PDIF, ADAT, and TDIF• ‘Analog Monitor Mode’ monitors A/D output through the D/A converter• ABS-96 operation allows recording of 24-bit/96kHz audio on 16-bit ADAT or TDIF machines• ABS (Apogee Bit-Splitting) allows recording and playback of 24-bit audio on 16-bit machines – available on

ADAT, TDIF and AES I/O.

Getting Started

The unit is shipped configured as independent A/D and D/A converters. We call this “Confidence Monitormode”.

Basic A/D conversion is simple:1. Connect your analog audio cables to the L/R ‘A/D inputs’. 2. Connect one of the digital outputs to the destination digital device (such as your DAT, ADAT, etc.).3. Power the unit on. All front-panel LEDs will illuminate except every other meter segment for about 3 sec-

onds, and some LEDs may briefly flash at power up, as the unit configures itself and runs diagnostics. Thisis normal. Hold down the OUTPUT RES button during the power-up sequence to restore factory defaults(except DIP switches). Otherwise the previous settings will be recalled.

4. You can choose to calibrate the unit to a desired operating level (see section titled “Calibrating the PSX”).The unit is calibrated from the factory so that +4dBu = –16dBFS and vice-versa for the D/A.

5. Play the analog sound source and check for metering at the destination device.

Basic D/A conversion is as follows:1. Connect the digital output of your digital device to the appropriate digital input of the PSX-100.2. On the front panel, select the appropriate digital input setting.3. With your monitor volume turned down, connect the ‘D/A outputs’ of the PSX-100 to your analog mixer or

preamplifier.4. Check for level from your speakers.

That’s it! You’re ready to begin recording.

For a more in-depth understanding of the PSX-100, we recommend that you examine the signal flow dia-gram below. You’re likely to understand more about the PSX-100’s three basic operational modes by carefullystudying the signal flow diagrams than by reading anything else in this manual.

PSX-100 User’s Manual

Page 11

Signal flow

There are 3 operational modes:

1. The most common mode is CONFIDENCE MONITOR MODE, where the unit’s A/D and D/A act com-pletely independently, taking advantage of the dual Apogee Low Jitter Clocks. In this mode, you can recordusing the PSX’s A/D converter and monitor the return of the recorder through the PSX’s D/A converter whilerecording (see example signal path below).

PSX-100 User’s Manual

Page 12

ANALOGINPUTSR CH

L CH

TDIF

ADAT

AES 2

AES 1

S/PDIFcoax/optical

MAINCLOCK

AUXCLOCK

ANALOGTRIM

SOFTLIMIT

A/D

24-bit,44.1–96kHz

METERS

24-bit,44.1–96kHz

D/A

AUX OUTAES

full res

MAINDIGITALOUTS TDIF

ADAT

AES 2

AES 1

S/PDIFcoax/optical

L CH

R CH

DIGITALINPUTS

UV22CTL

MUTEL, R

ABSCTLOUT

ABSCTLIN

You are “confident” that the signal on tape is OK because you’re listening to the return of the recordingdevice instead of the straight feed from the A/D converter. Keep in mind that some recorders do not have aconfidence monitoring feature, in which case, you will not actually be monitoring the signal off the tape itselfbut rather the signal straight through the recording device. Check with the corresponding manual or manufac-turer to see whether or not your recorder supports confidence monitoring. The lack of a confidence monitor-ing mode will not affect the functionality of the PSX-100; that is, the PSX’s D/A will play back whatever is fedto it.

In Confidence Monitor mode, the A/D section and D/A section are independent of each other – just likehaving separate A/D and D/A converter boxes sitting side by side. For example, the A/D section can be clockedfrom the internal CRYSTAL at a 48 kHz sampling rate feeding your ADAT while the D/A section is receiving dig-ital audio from your CD player at 44.1 kHz. The diagram on the previous page shows the PSX in a typical record-ing application.

To verify that the unit is in confidence monitor mode, the ‘A/D OUT’ LED under the heading ‘D/A INPUT’and the DCOPY light should not be illuminated.

2. The second mode is ANALOG MONITOR MODE, where the A/D input is routed to all digital outputs(including AUX out) as well as the D/A output. This differs from confidence monitor mode in that the feed fromthe A/D converter is routed directly to the input of the D/A converter. So what you’re monitoring is not thereturn from the recorder as in confidence monitor mode: instead it’s the output directly from the A/D. Below isa typical recording application using analog monitor mode.

While mixing, for example, it is often convenient to be able to listen to the mix through the A/D and D/Aso you know exactly how it will sound when it is laid to tape (e.g., hear the result of the A/D conversion, SoftLimit, UV22HR, etc). In Analog Monitor mode, you can do this while not tying up your mixdown deck (i.e., hav-ing it constantly in record through mode). You can switch between analog monitor mode and confidence mon-itor mode to compare the direct signal to the signal coming from ‘tape’ (or disc, etc).

To enter this mode, press and hold the ‘D/A INPUT’ button. The ‘A/D OUT’ LED will light (under the head-ing D/A INPUT) to indicate that the unit has entered ANALOG MONITOR mode.

PSX-100 User’s Manual

Page 13

3. The third mode is DIGITAL COPY MODE, where the selected digital input is routed to all digital out-puts (including AUX) as well as the D/A output. Note that this is a digital input only mode and that the analoginputs are not routed anywhere. This mode is useful for doing multiple format conversions. In the diagrambelow, the signal from an ADAT is fed to the optical input and is then format-converted and fed to all the dig-ital outputs and the D/A converter.

Connections

Please refer to the fold-out front and rear panel illustrations provided elsewhere in this Manual.Note that the Word Clock input also serves as the input for video sync when the optional Video Sync

Module is installed.

Controls & Indicators Please refer to the fold-out front and rear panel illustrations provided elsewhere in this Manual.

ButtonsThe buttons to the left of the meters generally apply to the A/D section and main outputs (some exceptions

apply). Some of the buttons serve double-duty. These buttons activate one feature when momentarily pressedand released and a different feature when pressed and held down for 2 seconds – see below.

PSX-100 User’s Manual

Page 14

A/D SYNC Determines sync source for the A/D section. If the unit is in ‘Digital Copy’ mode, this is automatically selectedto DIG IN. When in ‘Digital Copy’ mode, signals connected to the analog inputs (A/D section) will not be rout-ed to the outputs. PRESS & HOLD to enter into 88.2k/96k sampling rate mode.

OUTPUT RESSets the resolution (word length, bit rate, etc.) of the outputs. The A/D and D/A converters always convert at24 bit but the output resolution can be processed through UV22HR to retain high-resolution sound at lower bitrate (e.g., 16 bit CD).

OPTICAL OUT Sets optical output format to either S/PDIF or ADAT.

SOFT LIM Turns Soft Limit on/off on analog input signal – see Analog Processing section.

ABS Turns bit-splitting mode on/off for MDM outputs – ADAT & TDIF only (for AES/EBU outputs see below). If ABSLED is already lit, Press & Hold will turn on ABS AES input and indicate this by briefly flashing this LED. Turningoff ABS also turns off ABS processing for AES – see Press & Hold below.

MUTE L Mutes left channel of the main digital outputs only. Does not affect meters, DAC or AUX.

MUTE R Mutes right channel of the main digital outputs only. Does not affect meters, DAC or AUX.

METERIn Confidence Monitor Mode, selects metering of A/D output or D/A input. In all other modes, this button isnon-functional. Press & Hold to clear clip indicators on meters.

DIG COPY Enters/exits Digital Copy mode (see Digital Copy under ‘Operation’ section). If you try to access digital copywhile in analog monitor mode, the AD OUT LED will flash to indicate that you must return to confidence mon-itor mode first. If you try to leave DIG IN as the AD SYNC when in digital copy mode, DIG COPY LED will blink.The PSX-100 will remember the sync source when leaving confidence monitor mode and reinstate it upon reen-try to confidence monitor mode.

DA INPUT Selects digital input. For TDIF, remember to supply WC IN, unless you have set DIP switch 1 ON (LRCK syncmode – see DIP Switches). PRESS & HOLD to enter into ‘Analog Monitor’ mode (refer to the applications sec-tion).

MDM IN Selects which channel pair of ADAT or TDIF will be used as input. Also selects which set of four channels is inputwhen ABS is on.

Press & Hold ButtonsThese additional functions are accessed by pressing the appropriate button and keeping it pressed for two sec-onds.

A/D SYNC Enters into ‘FAST’ (88.2/96kHz sampling rates) mode – The x2Fs LED will light indicating that a 88.2K or 96Ksample rate is selected. The output resolution is automatically selected to full 24-bit. All ‘MDM IN’ LEDs willlight up, indicating that incoming MDM signals are expected to be in Apogee’s 96K format (and would be trans-mitted similarly). The ABS LED will go out (if it was previously lit) indicating that there is only one format option(i.e., that regular “pairwise” ABS does not function when the PSX-100 is in ‘FAST’ mode).

PSX-100 User’s Manual

Page 15

If the D/A input is AES, D/A INPUT will show AES1 and AES2 illuminated, indicating that ‘double wide’ AESformat is expected (see 96 kHz AES format table). S/PDIF is inactive for these rates (Note: S/PDIF A/D outputsat 44.1/48 kHz – every other sample – in FAST mode). If the video card is installed, the system automaticallygenerates 88.2 or 96 kHz sample rates from video inputs. Press & Hold again to exit FAST mode.

OUTPUT RESHold this button down DURING POWER-UP until the power-on display stops to reset the PSX-100 to the fac-tory defaults (except DIP switches). Otherwise the last-used settings will be recalled.

ABS If the ABS LED is already lit, Press & Hold to turn on ABS processing for the AES outputs and indicate this byflashing the ABS LED. Remember, the ABS LED must be lit prior to Press & Hold to enable ABS for the AES out-puts. Press & hold again to turn off ABS for the AES outputs, the LED will stop blinking to indicate ABS for theAES outs is off. NOTE: DIP Switch 8 controls ABS on AES INPUTS. At 88.2/96kHz sample rates, ABS is not avail-able on the AES inputs and outputs as both connectors are used.

METER Clears clip indications. Clips are held indefinitely unless DIP Switch 2 is set to ON (2 second hold). See DIPswitches.

D/A INPUT Enters analog monitor mode (see OPERATION). Press & Hold again to return to confidence monitor mode.If you try to access analog monitor mode while already in digital copy mode, DIG COPY will blink, indicatingthat you must return to confidence monitoring mode first.

MDM IN ABS processing on MDM inputs. LEDs 1-2 and 3-4 will light up. You can then toggle to 5-6 and 7-8 by brieflypressing the MDM IN button. Press & Hold again to return to simple 1-2. Not valid for 88.2/96K operation.

SOFT LIMPress & Hold to enter CAL mode (“meter zoom”). The SOFT LIM LED will blink. See Calibration under exter-nal settings.

MUTE L, RIf the optional Video Sync Module is installed and “VIDEO” is selected as the A/D SYNC, pressing and hold-ing the L or R button “pulls up” (multiplies) or “pulls down” (divides) the sample rate by 1.001 respectively.

DIG COPYIn Digital Copy mode, the output of the interface used for digital input is normally muted to avoid feedback (egyou can’t copy from S/PDIF to S/PDIF). Press & Hold DIG COPY to enable Loop Mute Bypass. The LED flashes.In this mode, all digital outputs are active – use with care to avoid feedback. To re-establish muting, exit DigitalCopy mode or Press & Hold DIG COPY again.

IndicatorsAD SYNC LEDsIndicates the source to which the ‘main clock’ (i.e., the clock of the A/D converter) is synchronized. When onDIG IN, the particular digital source to which the clock is locked is indicated at DA INPUT.NOTES: • DIG IN will normally be indicated when the PSX-100 is in Digital Copy mode. An exception is when doing a

digital copy from TDIF, during which WC will be indicated (DIP switch 1 ON – LRCK). • A/D sync will skip VIDEO in the toggling cycle unless the optional card is installed. • ERROR simply means loss of lock. It has been Apogee’s experience that CRC checking should not be

employed because some digital sources do not encode it properly, leading to false errors.

x2Fs LED Indicates that the entire system is running in ‘FAST’ mode (i.e. at 88.2 or 96 kHz sample rates).

PSX-100 User’s Manual

Page 16

OUTPUT RES LEDsIndicate the resolution of the digital outputs. The PSX-100 always converts at 24-bit resolution. When record-ing to 20-bit or 16-bit device, UV-22 may be applied to the outputs to maintain as much as possible of the orig-inal 24-bit resolution without truncation. If a truncated 20- or 16-bit output is desired (for instance, when record-ing into a sampler audio that is going to be drastically pitch changed) set OUTPUT RES to 24-bit: the recorderwill truncate the appropriate number of LSBs (least significant bits).

OPTICAL OUT LEDsIndicate the format that will be present at the optical output – S/PDIF or ADAT.

SOFT LIMIT LEDIndicates that Soft Limit is enabled for the analog inputs.

MUTE L, MUTE R LEDsIndicate that the main outputs are muted (left or right respectively).

ABS LEDIndicates that Apogee Bit Splitting is activated for the ADAT and TDIF outputs.

LEVELMeter segments light when signal exceeds the indicated level.

OVER LEDsOVER indicates a digital level of ±full scale had occurred on the respective channel for the number of consec-utive samples (1–4) determined by DIP switches 6 and 7. Overs are held indefinitely (until manually cleared)unless DIP 2 is set (which provides 2-second hold).

METER LEDIndicates which signal (A/D output or D/A input) is being metered when in confidence monitor mode. When ineither analog monitor mode or digital copy mode, both LEDs are lit since in each case there is only one sig-nal to meter (either A/D or digital input respectively).

DIG COPY LEDIndicates that the PSX-100 is in digital copy mode (see Operational Notes).

D/A INPUT LEDsIndicate selected digital input.

NOTES: • In analog monitor mode (or confidence monitor mode when synced to a digital input), the digital audio input

can be used for sync purposes even if the audio portion of the signal is not used. • In analog monitor mode, A/D OUT is usually lit. When using a digital input as sync source, (A/D Sync = DIG

IN) the appropriate dig input LED will illuminate. • A/D OUT lit indicates that the PSX-100 is in Analog Monitor Mode.• In 88.2/96K operation, both AES 1 and AES 2 LEDs will be lit indicating that both AES inputs are necessary

for L/R 88.2K or 96K D/A operation.

D/A SYNCIndicates ‘AUX clock’ synchronization. The AUX clock runs the AUX digital output and the D/A Converter.

NOTES:• When the A/D SYNC LED is lit, the AUX clock is slaved to the Main Clock (and is therefore synchronized to

the A/D SYNC source). • The LOCK LED indicates that proper clock/data synchronization has been established.

PSX-100 User’s Manual

Page 17

• ERROR simply means loss of lock. • CRC error checking is not employed because some digital playback devices do not encode it properly, lead-

ing to false errors (eg the PSX-100 will not indicate an ERROR when receiving a CRC error flag).

MDM IN LEDsIndicate which MDM channel pair is being monitored. • When two LEDs are lit (eg 1-2 and 3-4), the PSX-100 is applying Apogee Bit Splitting processing on the

MDM inputs to reconstruct a 44.1 kHz or 48 kHz bit-split signal. • When all four LEDs are lit, the PSX-100 is applying Apogee Bit Splitting processing on the MDM inputs to

reconstruct a 88.2kHz or 96kHz bit-split signal.

DIP SwitchesThe unit is shipped default from the factory with all the DIP switches in the OFF (down) position. The function-ality is as follows:

DIP Function OFF (Down—default) ON (Up)1 TDIF CLOCK TDIF clock is WC input TDIF clock is LRCK

See Note (1) below (clock signal in multipinTASCAM connector)

2 ‘OVER’ LED HOLD TIME infinite OVER LED hold See Note (2) 2 second OVER LED hold3 A/D INPUT POLARITY pin 2 hot pin 3 hot4 NOMINAL OUTPUT LEVEL +4dBu (professional) –10 dBv (consumer)5 NOMINAL INPUT LEVEL +4dBu (professional) –10 dBv (consumer)6 OVER THRESHOLD See OVER Threshold below7 OVER THRESHOLD See OVER Threshold below8 AES BIT-SPLITTING MODE ABS OFF on AES inputs Paqrat or ABS bit-split signals

always combined from two AES inputs (not applicable at 88.2/96 kHz sampling)

9 SINGLE/DOUBLE WIRE Single-wire operation 88.2/96 Double-wire operation10 WC OUTPUT RATE WC output is same as main rate WC output is 44.1/48 kHz

always, even when unit samplesat 88.2/96 kHz. See Note (1)

NOTE 1: 88.2/96 kHz Word Clock operation and TDIF. DIP Switch 1 OFF selects Word Clock as the clocksource for TDIF. While operating at high sample rates (88.2/96 kHz), when the A/D SYNC is set to Word Clockand the DA INPUT is TDIF, the PSX-100 expects a 44.1/48 kHz Word Clock. If the DA INPUT is NOT TDIF, thenthe unit expects an 88.2/96 kHz Word Clock for AD SYNC to Word Clock. When using Word Clock to sync aTDIF machine while bit-splitting at 88.2/96 kHz, be sure that DIP 10 is set to ON, as the TDIF device will berecording at 44.1/48 kHz even though the converter is running at 88.2/96 kHz.

NOTE 2: Over Autoclear. When DIP Switch 2 is set toOFF (infinite peak hold), AutoClear becomes active.This feature clears the OVER LEDs when the level hasremained below about –50 dB for more than 30 sec-onds and has then risen above –50 dB.

OVER ThresholdThe PSX-100 allows the user to select the number ofconsecutive OVERs required to illuminate the OVER indicators. When this threshold is set to 1 sample, everysample that exceeds 0 dBFS (0 dB Full Scale – digitally, this corresponds to “all ones”, ie the maximum level youcan convert) in level will trigger the OVER LEDs. When it is set to 4 samples, the OVER LEDs will only illuminatewhen four consecutive samples are OVER 0 dBFS.

PSX-100 User’s Manual

Page 18

When recording signals with sharp transients – drums and percussion, for example – many engineers do notmind occasional 1 to 3 consecutive sample overs (in fact, some record with overs on purpose!). Remember thatone sample is a very short period of time. Often 1 or 2 consecutive clipped transient samples will not neces-sarily be apparent. One reason to avoid having the threshold set at 1 sample in these situations is so that theengineer is not persuaded to lower the recording level to tape/disk when the indicators are only registeringtransient OVERs. On the other hand, during the mastering process, it is important not to register any OVERs inorder to avoid problems at the pressing plant.

The chart below shows the position of DIP switches 6 and 7 for different consecutive sample thresholds.

DIP 6 DIP 7 # of consecutive OVERs needed to illuminate OVER LEDs

down down 4up down 3down up 2up up 1

External Settings

Calibration Mode (“Meter Zoom”)Press & Hold the SOFT LIM button to enter Calibration Mode. The SOFT LIM LED will flash. In this mode, themeter scale reads from –20 dBFS (bottom LED) to –11 dBFS (top LED), ie one LED per dB, and the OVER LEDilluminates when the level is within ±0.1 dB of the indicated value. CAL mode only affects the meters, and canthus be used whether metering the A/D or D/A, in any operational mode.

D/A CalibrationThe D/A converter can be calibrated over a wide range of likely operating values. It is calibrated from the fac-tory so that an incoming digital signal at –16dBFS produces a level of +4dBu at the analog outputs. So, forexample, if you wanted the D/A converters to output a hotter (louder) signal at the analog outputs, you wouldfeed the digital input a level under –16dBFS (for example, –18dBFS) and calibrate the outputs until the analogoutput level read +4dBu. Likewise, if you wanted a lower DAC output, you would feed the unit a –14 dBFS sig-nal, for example, and calibrate the DAC accordingly. On the next page are brief instructions on how to calibratethe D/A and A/D converters.

PSX-100 User’s Manual

Page 19

As set at the factory, a digital signal at–16dBFS produces a level of +4dBu at theanalog outputs.

Calibrating the D/A Converter

1. Use an external source to provide digital signal to the D/A.2. Verify that D/A SYNC is correct and locked.3. Ensure that DIP switch 4 (Output level) is set correctly: OFF for +4dBu, ON for –10 dBV4. Using a ‘tweaker’ or small flathead screwdriver, rotate the left and/or right trimpot in a clockwise direction

to increase gain of the D/A. It is not necessary to use a non-conductive tool.

Calibrating the A/D Converter

1. Ensure that DIP switch 5 (Input level) is set correctly: OFF for +4dBu, ON for –10 dBV.2. Using a ‘tweaker’ or small flathead screwdriver, rotate left and/or right trimpot in a clockwise direction to

increase gain of the A/D. It is not necessary to use a non-conductive tool.

Using the AUX OutputThe AUX connector on the rear of the PSX-100 is an auxiliary AES output which, when available, always deliv-ers full 24-bit resolution. It was originally designed to allow easy connection of an external, high-accuracy digi-tal meter for mastering and monitoring applications; however it also has other uses.

The AUX output is essentially the same signal as appears at the INPUT of the D/A Converter in the PSX-100. Ifyou bear this in mind when you wish to use the AUX connector, you won’t go far wrong.

The AUX output is available at 88.2/96 kHz sample rates (FAST mode), but it will only output every other sam-ple, at 44.1/48 kHz. This may be fine for metering, but the filtering will be wrong for accurate 44.1/48 kHzrecording and we do not recommend its use for recording purposes in FAST mode.

Typical Applications

MeteringWhile using the PSX-100 A/D and D/A in Confidence Mode, for example wrapped around a digital recorder, theAUX output can be used to connect an external metering system for increased accuracy. The AUX output deliv-ers the same signal as is present at the D/A input, so you will need to insure that a useful signal is being returnedto the D/A inputs from the recorder, or this output will not work!

Recording a 24-bit signal while simultaneously recording one or more 16-bit signalsThe AUX output is always operating at full 24-bit resolution. As a result, you can connect it to the AES input ofa 24-bit recorder such as the Tascam DA-45HR while you have the main outputs set to 16-bit UV22HR – the lat-ter being sent to, for example, one or more 16-bit DAT machines. It is tempting to use Confidence Mode forthis purpose… you can’t! Confidence Mode separates the A/D and D/A , and the AUX output is the same as theD/A input, so if you feed the output of the DA-45HR to the D/A input and the AUX output to the DA-45HR inputyou will in fact be creating a feedback loop!

The solution is to use Analog Monitor Mode. In this mode, the A/D feeds both the main outputs and the AUXoutput; the AUX output is always 24-bit; and you can simultaneously use UV22HR on the main outputs. In addi-tion, the D/A is fed from the A/D as well, so if you monitor the D/A output you will simply be listening to theA/D converter. Note that you will need to switch out of Analog Monitor Mode to replay the recorded signal,and you should temporarily disconnect the path from the AUX output at the same time to avoid a feedbackloop when you are not in replay on the DA-45HR.

You can, incidentally, use the DA-45HR locked to the PSX-100 crystal at all times, using the Word Clock outputfrom the PSX-100. This will insure that you do not lose sync when the AUX output ceases to generate usefuloutput in Confidence Mode (which would be the case if you were relying on the AES signal for sync).

PSX-100 User’s Manual

Page 20

Internal Settings

The following information is provided for authorized technicians only and is not intended for use by theuser. Adjustment of internal settings by non-authorized persons will void the warranty. Technicians areexpected to follow appropriate ESD practices.

Voltage settingWith the power cord disconnected, use a coin or flathead screwdriver to align the desired voltage setting withthe white mark at the perimeter of the selector switch. Ensure that you are using the proper fuse – see below.

FusesCAUTION For protection against risk of fire, replace only with same type and rating of fuse: 100/120V~operation: 250V, 800mA, T (Slow Blow); 220/240V~ operation: 250V, 400mA, T (Slow Blow).

Soft limit calibration on A/D The soft limit threshold is factory calibrated for –4 dB but can be adjusted as necessary.

To adjust Soft Limit threshold for either channel, rotate VR12 (left channel) or VR15 (right channel) to set thethreshold at which Soft Limit begins to operate. To reduce the risk of miscalibration, calibration should be per-formed with an Audio Precision System One, System Two or similar equipment.

Common mode rejection adjustment on A/DTo trim the common mode rejection, rotate VR13 (left) or VR10 (right) while shorting pins 2 and 3 of the chan-nel’s analog inputs together and monitoring the digital output. Find the position where the output level is min-imized.

DAC pin 3 hot jumpersThe PSX-100 provides jumpers for the DAC output to be pin 3 hot. Default fromfactory is pin 2 hot.

The jumpers, which are mounted near theXLR connectors as shown, should be perpendicular to the aluminum trimrods for pin 2 hot.

Optional video card installationWith unit powered off, the 20 pin header on the video card is pressed into the J2 header on the main board.

Make sure pin 1 on the card lines up with pin 1 on the header, as marked on board.

PSX-100 User’s Manual

Page 21

Pin 3 hot Pin 2 hot

Operational NotesThere are 3 operational modes. The most commonly-used is confidence monitor, where the unit’s A/D and D/Aact totally independently. Remember that the AUX output replicates the D/A input signal, not the A/D out.

The second is digital copy, where the digital input is routed to all digital outputs including AUX as well as theD/A output.

The third is analog monitor, where the A/D input is routed to all digital outputs including AUX as well as theD/A output.

• You can switch between confidence monitor mode and digital copy mode; • you can switch between confidence monitor mode and analog monitor mode; • you cannot switch directly from analog monitor mode to digital copy or vice versa.

Confidence Monitor ModeIndependent A/D and D/A. Select which signal is to be metered via the METER button.

Digital Copy ModeThe selected digital input goes to all outputs (except the input interface) including AUX and D/A OUTPUT.A/D SYNC will read DIG IN (except WC for TDIF). METER shows A/D and D/A, signifying that there is only onesignal. • If you try to access digital copy while in analog monitor mode, the AD OUT LED will flash to indicate that

you must return to confidence monitor mode first.

Analog Monitor ModeThe A/D input goes to all outputs including AUX and D/A OUTPUT.D/A SYNC will read A/D SYNC, plus optionally digital in if A/D SYNC is selected to DIG IN. METER shows A/Dand D/A, signifying that there is only one signal. D/A INPUT will show A/D OUT only, unless AD sync sourcehappens to be selected to digital in. In this case, one of the six digital source LEDs will light, and you can tog-gle through them. If you try to access analog monitor mode while already in digital copy, DIG COPY will blink.

ABS (Apogee Bit Splitting) Processing – Outputs

For 88.2/96 kHz operation, the outputs are in a sense bit-split but there is only one output format – see 88.2/96kHz operation. Note that applying ABS processing defeats UV22HR processing on the bit-split outputs, despitethe UV22HR indication on the front panel. A bit-split output will not be processed with UV22HR although otheroutputs could be processed with UV22HR at the same time. So, for example, if you are recording to an ADATand a DAT at the same time during a mix, you could use bit-splitting to record to the ADAT at 24-bit and makea back-up copy to DAT at 16-bit using UV22HR.

If you are operating in Confidence Monitor Mode at 44.1/48 kHz sampling, and you hit ABS, the MDM IN auto-matically goes to two pairs; if your turn off ABS, MDM IN reverts to one pair. You can override these settings.

MDMIn 44.1/48k sample rates, the PSX-100 can ‘bit-split’ the MDM (ADAT and TDIF) outputs as shown over. This fea-ture is enabled by the ABS button, and controls TDIF and ADAT outputs simultaneously.

In the list overleaf, L16 means left upper 16-bits, T8 means 8-bit tone (which begins in most significant bit), L8refers to the left lower 8 bits, etc.

PSX-100 User’s Manual

Page 22

MDM ABS Format

Channel Normal ABS1 L16 L162 R16 T8+L83 L16 R164 R16 T8+R85 L16 L166 R16 T8+L87 L16 R168 R16 T8+R8

AESThe AES outputs AES1 and AES2 can operate similarly, useful for 16-bit machines. This is done by first enablingABS for MDMs, then press & hold until the ABS LED blinks, showing that ABS AES is enabled. Another press& hold turns ABS AES off.

AES ABS Format

Channel Normal ABSAES1 LEFT L16 L16AES1 RIGHT R16 T8+L8AES2 LEFT L16 R16AES2 RIGHT R16 T8+R8

S/PDIFABS output processing is not supported for S/PDIF regardless of whether or not the ABS LED is lit.

ABS (Apogee Bit Splitting) – InputsFor 88.2/96 kHz operation, the inputs are in a sense bit-split but there is only one input format – see

88.2/96 kHz operation.

MDMAt 44.1/48 kHz sample rates, the PSX-100 can ‘bit split’ the MDM (ADAT and TDIF) inputs. This feature is

enabled by press & hold of the MDM IN button, and controls TDIF and ADAT outputs simultaneously. Press andhold will light both 1-2 and 3-4 LEDs at the same time. This means these four channels inputs will be combinedper the MDM ABS format shown in ABS PROCESSING – OUTPUTS. You can then hit MDM IN once to selectchannels 5-8 as the inputs. Press & hold returns to NON-ABS channels 1-2.

NOTE: In Confidence Monitor mode and 44.1/48 kHz sampling, turning on ABS will automatically set the MDMIN configuration to two pairs (1 and 2). When you exit from ABS, MDM IN will select one pair (channels 1 and2). You can always override these settings.

AESThe AES inputs AES1 and AES2 can operate similarly, useful for 16-bit machines. This is done by setting

DIP8, which manually forces the AES format described in ABS PROCESSING – OUTPUTS.

S/PDIFABS processing is not supported for S/PDIF.

PSX-100 User’s Manual

Page 23

88.2/96 kHz Operation

• Press & hold A/D SYNC button to enter FAST (88.2/96 kHz) mode. See “press & hold” buttons section.• Note that when the x2Fs LED is lit, both digital inputs and digital outputs are operating at the 88.2/96 kHz

formats. It is not possible for example, to do A/D conversion at 88.2 kHz but D/A at 44.1 kHz.

There are no MDM output format options in FAST mode: ABS-96 is used, with the format indicated below.Meanwhile, the AES and S/PDIF outputs operate ‘double-wide’ (double wire) or ‘double-fast’ (single-wire)according to the setting of rear panel DIP switch #9 – UP for double-wire and DOWN for single-wire operation.

Given an 88.2/96 kHz datastream comprised of L1, R1, L2, R2 = A, B, C, D (where L=left, 1 occurs before 2)T8 = tone, A16 = upper 16-bits of sample A, A8 =lower 8 bits of sample A:

MDM 88.2/96 kHz (“ABS-96”) Format

Channel 88.2/96 kHz1 A162 B163 C164 D165 T8+A86 T8+B87 T8+C88 T8+D8

The AES outputs AES1 and AES2 can operate similarly:

Double-wire AES 88.2/96 kHz Format (DIP switch 9 UP)

Channel Normal ABSAES1 LEFT L16 L1 24-bitsAES1 RIGHT R16 L2 24-bitsAES2 LEFT L16 R1 24-bitsAES2 RIGHT R16 R2 24-bits

NOTES:• The S/PDIF output and AUX outputs drop every other sample and transmit as usual at 44.1/48 kHz. • The digital inputs are expected to be formatted as above at 88.2/96 kHz. • Locking to S/PDIF when in FAST mode is inhibited. • Due to the use of both AES 1 and 2 connectors for a single stereo path in FAST mode, the functionality

available at 44.1/48 kHz is not available at 88.2/96 kHz sample rates.

88.2/96 kHz Word Clock and TDIFDIP switch 1 selects WC as the clock source for TDIF. This operates as follows:

In FAST mode (x2Fs), with A/D SYNC set to WC (Word Clock) and D/A INPUT set to TDIF, the PSX-100 willexpect a 44.1/48 kHz Word Clock. If the D/A INPUT is something other than TDIF, then the unit will expect aFAST Word Clock (88.2 or 96 kHz).

PSX-100 User’s Manual

Page 24

PSX-100 User’s Manual

Page 25

Single-Wire Operation at 88.2/96 kHz (DIP Switch #9 DOWN)

With Firmware Revision 3.0.0 onwards, the PSX-100 has the capability of “single wire” operation in addition tothe existing “double wide” specification. The provision of both methods of interfacing at high sample rates makesthe units compatible with the vast majority of AES devices utilizing 88.2/96 kHz sample rates.

The PSX-100 converter previously interfaced high sample rate (88.2/96 kHz) digital audio signals via two AES con-nectors (so-called “double-wide” mode). Channels 1 and 2 carry the left and right signals respectively with eachchannel functioning at half the active sampling rate (i.e., for a 96kHz stereo signal, each side clocks at 48 kHz). Thisimplementation is compatible with many other companies’ devices including Nagra-D and Genex recorders, andSADiE digital audio workstations.

Your PSX-100 includes the additional capability to handle stereo 88.2 or 96 kHz signals via a single cable (so-called“double-fast” or “single-wire” mode). In this mode, the stereo signals are interleaved in a similar way to the normalAES implementation for 44.1 and 48 kHz, but at twice the speed. This functionality is also available via the S/PDIFCoax and Optical interfaces. This feature makes the PSX-100 compatible with the high sample rate functionality ofother manufacturers’ products including TC Electronic and Weiss processors, and many computer digital I/O cards,while retaining the existing “double-wide” interface capability. Rear-panel DIP switch #9 is used to select the high-speed interface mode: UP for double-wire, DOWN for single-wire.

Note that “single-wire” interfacing may not be compatible with all devices. Digital audio routers in particularmay not be able to operate at double speed, and digital audio cabling may have a reduced practical operat-ing length. We advise users to check with their equipment suppliers to ensure compatibility.

With DIP Switch #9 DOWN, when x2Fs is selected, single-wire I/O is implemented on the AES1,AES2, S/PDIFCoax and S/PDIF optical connections. TDIF and ADAT functionality (including ABS96) remain as before.

UV22HR ProcessingUV22HR is used to output audio at 16-bit or 20-bit while maintaining much of the detail of the original 24-bitsignal. When applied, the UV22HR-processed audio is fed to the main outputs. The AUX and D/A outputs arenever processed. UV22HR is presently disabled for 88.2/96 kHz operation as it has very limited, if not non-exis-tent, applications.• Use the PSX-100 in digital copy mode to apply UV22HR to a digital signal.

Optional Video CardWhen installed (see Internal Settings) the A/D SYNC button will include VIDEO in the toggling cycle. The PSX-100 will measure incoming sample rate for PAL, NTSC, or MONO and set hardware for 44.1k sample rate: pressA/D SYNC again to go to 48kHz. The card will automatically provide 88.2/96kHz when the higher sample ratesare selected. Input the video signal via the WC-IN/VID connector on the rear panel.

When A/D SYNC is set to video, you can bump up the sample rate (x1.001) by pressing and holding the MUTEL button. Likewise, the sample rate can be bumped down (÷1.001) by pressing and holding the MUTE R but-ton. To disable pull up/down, press the A/D SYNC button again.

• Pull up is indicated by a 75% duty cycle blinking of the video LED (ON longer that OFF).• Pull down is indicated by a 25% duty cycle blinking of the video LED (OFF longer that ON).

Miscellaneous FeaturesAnalog ProcessingThe PSX-100 A/D section includes Common Mode Reject circuitry, a DC removal circuit, and Soft Limit (whenenabled). The PSX-100 D/A section includes cross-coupled outputs which allow connection of a balanced signalvia single-ended cable.

Nonvolatile memoryThe PSX-100 will remember front panel settings when powered down, and configure itself to those states atpower up (unless OUTPUT RES is held down during the power-up sequence). Some states may not be remem-bered because the unit may have been powered down while in an error condition or some other disallowed con-dition. This is normal and does not indicate a PSX-100 malfunction. Check the ERROR conditions overleaf.

Self-clockingAll digital input sources are self-clocking – the PSX-100’s D/A section will automatically clock to the selecteddigital input signal. So, for example, the D/A cannot clock to CRYSTAL while trying to input an AES signal. Theonly exception is TDIF, which normally syncs to the WC input.

Loopback muting Normally, Digital Copy mode mutes the digital output that corresponds to the interface being used for digitalinput. This is to avoid creating a feedback loop through an external device such as a recorder. Thus, normally,you cannot, for example, copy between ADAT and ADAT. Should you need to do this – for example, you wantto source a signal from one S/PDIF machine and copy it to two other machines simultaneously, using bothS/PDIF coax and optical, or you want to copy between two ADAT machines – you can defeat the loopback mut-ing feature. Press & Hold the DIG COPY button. The LED flashes. Be careful in this mode as it may be possibleto create a damaging feedback loop. Press & Hold DIG COPY again to re-establish automatic loopback muting,or simply exit Digital Copy mode.

Word Clock OutWord Clock Out is derived from the main clock, which is the A/D SYNC source. Remember that when A/D SYNCis selected to DIG IN, the main clock is slaving from the digital input source and the WC will be derived from it.

PSX-100 User’s Manual

Page 26

Auto-muting

In CONFIDENCE MONITOR mode:When switching A/D sync sources, the main outputs will automatically mute (both L and R, with no indication)until the clock re-locks.

When switching D/A INPUT sources, the AUX and D/A outputs will automatically mute (both L and R, with noindication) until the clock re-locks.In DIGITAL COPY mode:In digital copy mode, the digital source serves both clocks so all outputs will mute until the A/D sync and D/ASYNC re-lock.

In ANALOG MONITOR mode:In analog monitor mode, the selected A/D sync source serves both clocks so all outputs will mute until the A/Dsync and D/A SYNC re-lock.

Also, when locked to digital in, changing input format (e.g., pressing MDM IN, press & hold MDM IN, or chang-ing DIP 8) will briefly mute those signal paths which use the digital input data.

Lock timing The PSX-100 employs ‘smart synchronization’. When syncing to a new source, the processor measures theincoming clock frequency. This processing causes a very slight delay in indicating LOCK when selecting a newclock source.

Polarity InversionDIP switch 3 controls whether A/D input pin 2 or 3 is hot and jumpers control whether the D/A output is pin 2or 3 hot. When setting the A/D section to pin 3 hot, remember that you will probably also need to set the D/Asection, using the output jumpers, to pin 3 hot.

MDM Channel duplicationIn 44.1/48 kHz “normal” (non-ABS) operation, the left and right (L/R) channels of the PSX are duplicated acrossall eight tracks of the MDM as follows:

ADAT CHANNELS 1 2 3 4 5 6 7 8PSX-100 CHANNELS L R L R L R L R

• When in ABS (bit-splitting) mode at 44.1/48 kHz, channels 1-4 will be duplicated on channels 5-8.

AutoclearIf DIP switch 2 is down (OVER LED infinite hold), the autoclear function is active. This feature will clear the clip(OVER) LEDs once the level has gone below –50dB for 30 consecutive seconds. The clip LEDs actually clearwhen the level has once again gone above –50dB after it has been below –50dB for over 30 seconds. This allowsthe user to know that there were OVERs during a certain pass because the clip LEDs will not actually clear untilnew audio is received after the pause. This feature is designed so that, when going on to a new recording ormix, the PSX-100 will not indicate a ‘false’ OVER from the last pass if the engineer forgot to clear the meters.This feature acts independently on Left and Right channels.

Error IndicationsCertain disallowed conditions are indicated by temporarily blinking LEDs. Note that some LEDs may blink atpower up: this is OK—the unit is configuring itself. Error conditions are detailed below:

PSX-100 User’s Manual

Page 27

CONDITION ACTION (press…) LED FLASHES REASONFast mode (ie, x2Fs LED lit) ABS x2Fs ABS does not work in FAST modeFast mode (ie, x2Fs LED lit) UV22 x2Fs UV22 does not work in FAST modeAnalog Monitor Mode DIG COPY A/D OUT Can’t go directly from Analog Mon to Digital CopyDigital Copy Mode & hold D/A INPUT DIG COPY Can’t go directly from Digital Copy to Analog MonAnalog Monitor, DIP1 OFF A/D SYNC TDIF If D/A is TDIF, A/D Sync cannot be DIG IN (TDIF clock = WC), had been because DIP 1 is set so that the clock for TDIFon TDIF, A/D SYNC = WC is word clock (DIP 1 = OFF) not LRCK.Fast mode (ie, x2Fs LED lit) MDM IN x2Fs Can’t change channel routing in FASTFast mode (ie, x2Fs LED lit) & hold MDM IN x2Fs Can’t change channel routing in FASTDigital Copy Mode A/D SYNC DIG COPY A/D SYNC must remain on DIG IN

when in DIG COPY mode

About UV22HR Super CD EncodingSqueezing more performance from a digital recording is not a new idea. It began with adding white noise, calleddither, to the digital audio. Plain dither was followed by different flavors of dither noise, then a process called‘noise shaping’, and various forms of so-called ‘bit mapping’. Systems have been introduced that store controlinformation in the least-significant bits and use a special decoder to recover the data on playback.

Independent listening tests confirm that these systems either color the recordings we are trying to pre-serve, or compromise the audible noise floor. Encode/decode systems may sound good if they are decoded,but almost nobody owns a decoder!

Apogee UV22HR Encoding – the latest and most powerful development of Apogee’s original UV22 process– is an entirely different approach. UV22HR does its job without sonic compromise, and without adding a soundof its own, preserving the sound stage and tonal balance of the original high-resolution source. The effects areeven audible on original 16-bit recordings.

UV22HR Encoding adds an inaudible, algorithmically-generated concentration of energy around 22 kHz.Much as the bias on an analog tape recorder smooths out magnetic tape recording non-linearities, UV22HRsilently captures resolution beyond 20-bits on a standard, 16-bit CD. In addition, this inaudible carrier smoothsthe rough edges of even the most inexpensive CD player or external converter. UV22HR makes your recordingssound better on all listening systems. Running already-mastered 16-bit sources through a UV22HR processordelivers sonic improvements that any user can realize on equipment they already own.

UV22HR is a very special information carrier: it is not a new flavor of dither noise. The truly unique statisti-cal properties of UV22HR guarantee a constant white noise floor, very similar in character to analog tape noise,no matter what the input source. If you listen to a UV22HR encoded recording, you can hear a stable, accuratesound stage and faithful tonal balance more than 24dB into the noise – just as you do on analog tape.

Yet the UV22HR’s low audible noise floor sits at the theoretical limit for a 16-bit system. Nothing is lost –but a great deal is gained. In listening test after listening test, engineers and reviewers alike choose UV22 overall other systems. Many thousands of CD titles have already been mastered using Apogee UV1000 Super CDEncoders, the AD-1000, and the industry-standard AD-8000 and PSX-100. Apogee’s UV22 is today in use in thevast majority of US mastering houses, and it is estimated that as many as 80% of the hit records mastered inthe United States today utilize UV22.

UV22HR Process ApplicationUV22HR Encoding is best applied as the final step in the signal chain before the actual mastering device. Forexample, if you are mastering a conventional 16-bit CD, but you have the ability to employ higher-resolutiondevices earlier in the chain, you should keep your signal at the highest resolution possible until the creation ofthe final master tape, and at that point apply UV22HR to reduce the word-length from high-resolution to thefinal 16-bit for Compact Disc. If you are recording at high density (long word-lengths, and 88.2/96 kHz or high-er sample rates) and need to generate a 44.1 kHz 16-bit CD master or a 48 kHz 20-bit DVD-Video master, firsthandle the sample rate conversion at the maximum word length available; then use UV22HR to reduce theword-length when you have a 44.1/48 kHz signal. Sample-rate conversion is a tricky business at best, and youneed the maximum resolution available when you do it. This is why we do not provide UV22HR at high samplerates.

PSX-100 User’s Manual

Page 28

Because of the addition of the UV22HR signal, we do not recommend that you use the UV22HR processmore than once or twice on a signal. Multiple passes through the UV22HR process could degrade the noise floorof the system at the upper frequencies and produce artifacts.

Recordings to be used in a sample or sound effects disc can be UV22HR encoded if pitch shifting is not like-ly to be employed, or if pitch shifting upward only is to be used. Pitch shifting downward on processed signalsrisks making the normally ultrasonic UV22HR energy concentration audible.

You can use UV22HR in conjunction with a wide range of both lossy and lossless compression technologiesused in DVD mastering, such as Dolby AC-3, DTS, and MLP (Meridian Lossless Packing). In addition, UV22HR isa very useful technique when used in conjunction with Internet audio delivery systems such as ‘MP3’ (MPEG1Layer III), Real Audio, QuickTime and other systems, where the ability of UV22HR to maintain high-resolutionquality and detail at the 16-bit level means smaller, better-sounding files and streaming audio signals, offeringmore effective use of available bandwidth.

Application NotesHigh-Density Conversion, Word Lengths and InterconnectsDespite the apparent proliferation of “96 kHz” devices, and the apparent demand for them from end-users,there are in fact few agreed standards for “high density” (ie 24 or more bit, 88.2 kHz, 96 kHz and above) con-version. Nowhere is this more true than in the world of digital interconnection. There is as yet, for example, nofinal standard for AES interfacing at high sample rates (although one is on the table at the time of writing). Youcan either use a single AES interface at double-speed (we call this “double-fast” mode), or a pair of interfacesat normal speed (we refer to this as “double-wide”). Both have advantages and disadvantages, and as a resulttheir adoption in the industry is about 50/50.

Apogee has chosen “double-wide” AES interconnection for our current series of high-density converters.This means that if the converter is running in “FAST” mode, each AES path only outputs half of the signal – infact it carries every other sample. Bear this in mind.

For most other digital interfaces at high speed, there is no standard. One manufacturer, for example, runsS/PDIF at double speed for 96 kHz. We don’t. Most MDM interfaces are not designed to operate at doublespeed, and we don’t support that either.

At present, we do not support the use of UV22HR at high sample rates. The reason is simple: it is almostcompletely unnecessary. (If you’re using the one machine we have ever heard of that records at 16-bit, 96 kHz– it’s the same one that uses double-speed S/PDIF – then I’m afraid we can’t help you.) In most cases you willwant to use shorter word-lengths in conjunction with lower sample rates – perhaps you’ll record at 24/88.2, butyou want to get a CD master at the end of the day. Or you are recording at 24/96 for a 20-bit, 48kHz DVD-Video release. Do your sample rate conversion first. The longer you maintain the maximum word-length, thebetter it will sound. Apply UV22HR to the 24-bit signal at the final sample rate.

We are aware of the fact that the DVD-Audio specification allows for different sample rates in the same“family” (44.1/88.2/176.4 kHz or 48/96/192 kHz) for different surround channels – say 96 kHz for the front and48 kHz for the rear – and that in theory you can use different word lengths as well or instead, including 88.2 and96 kHz at 16 or 20 bits. However, the general view at present is that longer word lengths are worth maintain-ing, even more than high sample rates.

We are keeping a careful eye on developments in these areas and will review our design criteria in the lightof industry requirements and developments. Check our Web site for the latest word: http://www.apogeedigi-tal.com/

If you want to…

• Record to a DA-88:

1. Connect the Word Clock output of the PSX-100 to the Word Sync input of the DA-88.2. Connect the Word Sync output of the DA-88 to the Word Clock input of the PSX-100.3. Connect the TDIF cable to the TDIF ports on the DA-88 and PSX-100. Make sure you use a 25-pin to 25-pin

cable that is specifically made for TDIF such as the PW88D cable from Tascam. Normal 25-pin computercables will not work (the wiring is different).

PSX-100 User’s Manual

Page 29

4. Set PSX-100 DIP switch #1 to OFF (TDIF input uses WC input for sync)5. Set PSX-100 DIP #10 to ON (WC connector outputs 44.1/48 kHz always)6. Power on the DA-88 and the PSX-1007. Make sure the PSX-100 is in Confidence Monitor mode (A/D OUT under D/A INPUT not lit)8. Select CRYSTAL under A/D SYNC (or alternatively VIDEO or WC if syncing to external video or word clock

respectively)*9. Set the DA-88 to DIGITAL IN and CLOCK = WORD10. Make sure that the PSX-100’s sample rate (under A/D SYNC) is set to the same rate as the DA-88 tape was

formatted11. Select the desired bit rate under OUTPUT RES. As of this writing, Tascam TDIF format recorders only record

16-bit data to tape. If you are not bit-splitting to tape, select ‘UV22 16 BIT’ (there are some instances whereusing UV22 may not be desirable – see UV22 Caveats)

12. Select TDIF under D/A INPUT13. Select the desired pair of tracks to monitor under MDM IN14. Record-arm the DA-88 tracks15. Check for levels on the DA-8816. Check for level at the analog outputs of the PSX-100

• Record 24-bit, 44.1/48 kHz bit-split to a DA-88:

1. Set everything as above2. Press the ABS button3. Record arm tracks 1-4 or 5-8 on the DA-88 for stereo L/R recording.

• Record 24-bit, 88.2/96 kHz bit-split to a DA-88:

1. Set everything as above (note that UV22 does not operate in FAST mode!)2. Press and hold the x2Fs button until the LED illuminates3. DO NOT press the ABS button, as MDM bit-splitting is the default mode for FAST operation4. Record arm tracks all tracks on the DA-88 (1-8) for stereo L/R recording.

Points to watch

1. DA-88 not locking to incoming Word Clock from the PSX: • Make sure that you are using a high-quality 75Ω coaxial cable for Word Clock in and out (e.g., Apogee

WydeEye AD part # WE-RR). Check the cable for shorts and continuity. • If the DA-88 does not lock to incoming WC, you may have to install an SY-88 sync card into your DA-88. Call

your Tascam representative for more information.• There seem to be some DA-88s that do not lock to some types of word clock. If you have a DA-88 with an

SY-88 card installed and have a working 75Ω cable and it still won’t lock, contact your Tascam representa-tive about the Word Clock circuit on your particular DA-88.

• If the PSX-100 is in FAST mode (you are bit-splitting at 88.2/96 kHz to the DA-88), make sure that DIP switch#10 in ON (UP) so that the PSX-100 outputs a 44.1/48 kHz word clock. If not, the PSX-100 will output an88.2/96 kHz word clock that the DA-88 will not understand.

2. If, for some reason, the PSX-100 D/A is not locking to Word Clock (ERROR condition), flip DIP #1 to ON(UP). The PSX will then clock to the LRCK clock embedded in the 25-pin cable.

• Record to an ADAT w/ BRC:

1. Connect the Word Clock output of the PSX-100 to the 48 kHz INPUT of the BRC. Note: The Word Clockoutput of the BRC does not need to be connected to the Word Clock input of the PSX-100 because theADAT inputs of the PSX-100 are ‘self-clocking’ (i.e., the PSX-100’s D/A slaves to the clock imbedded in theoptical signal).

PSX-100 User’s Manual

Page 30

2. Connect the optical output of the PSX-100 into the optical input of the ADAT and vice versa.3. Set PSX-100 DIP #10 to ON (WC connector outputs 44.1/48 kHz always).4. Power on the BRC/ADAT(s) and the PSX-100.5. Make sure the PSX-100 is in Confidence Monitor mode (A/D OUT under D/A INPUT not lit).6. Select CRYSTAL under A/D SYNC (or alternatively VIDEO or WC if syncing to external video or word clock

respectively)*.7. Set the BRC to DIGITAL IN by pressing the DIGITAL I/O button (make sure that the digital I/O format is

ADAT by pressing EDIT>DIGITAL I/O).8. Set the BRC to clock to the 48K input by pressing EDIT>EXT SYNC and choosing ‘48 kHz Input’. Then press

EDIT to escape EDIT mode and press EXT SYNC to put the BRC in EXT SYNC mode.9. Make sure that the PSX-100’s sample rate (under A/D SYNC) is set to the correct rate.10. Select the desired bit rate under OUTPUT RES. (there are some instances where using UV22 may not be

desirable – see UV22 Caveats)11. Select ADAT under D/A INPUT.12. Select the desired pair of tracks to monitor under MDM IN.13. Record-arm the ADAT tracks.14. Check for levels on the ADAT.15. Check for level at the analog outputs of the PSX-100.

• Record 24-bit, 44.1/48 kHz bit-split to an ADAT:

1. Set everything as above.2. Press the ABS button.3. Record arm tracks 1-4 or 5-8 on the ADAT for stereo L/R recording.

• Record 24-bit, 88.2/96 kHz bit-split to an ADAT:

1. Set everything as above (noting that UV22 is not available in FAST mode!).2. Press and hold the x2Fs button until the LED illuminates.3. DO NOT press the ABS button, as bit-splitting is the default mode for MDM recording at high sample rates.4. Record arm tracks all tracks on the ADAT (1-8) for stereo L/R recording.

*There are very specific reasons to sync to external video or word clock and users who need to do this usu-ally know exactly how and why. If you don’t know why you would need to sync to external video or word clock,then, chances are, you don’t need to do it.

PSX-100 User’s Manual

Page 31

PSX-100 User’s Manual

Page 32

The Apogee PSX-100 — Specifications

ANALOG AND A/D CONVERTERParameter Value UnitsResolution 24 bitsSample Rate 44.1–48, 88.2–96 kHz ±10%Input Impedance

Pro 9K ΩConsumer 15K Ω

Relative THD+N–0.1 dBFS –110 dB (unweighted)

–112 dB (A-weighted)–20 dBFS –91 dB (unweighted)

–93 dB (A-weighted)–60 dBFS –56 dB (unweighted)

–58 dB (A-weighted)Dynamic range

–60 dB, Unweighted 116 dB–60 dB, A-weighted 119 dB

Peak Spurious Component –126 dB (max)Group Delay (in passband) 34/Fs secondsPassband Ripple ±0.001 dBDigital Filter Stopband 0.5542Fs kHzStop-band Attenuation 117 dBChannel Separation

Left/right 120 dB (worst case)Frequency Response (10 Hz–20 kHz)

Gain ±0.025 dBPhase < 0.01 degrees

Common-Mode Rejection Ratio60 Hz >> 100 dB1 kHz >> 80 dB

Input Level, maximum (no gain)Professional, balanced 27 dBuProfessional, unbalanced 23 dBuConsumer, balanced 16 dBuConsumer, unbalanced 15 dBu

Input Level, adjustment range 20 dBuCrystal Oscillator accuracy ±50 ppmClock Jitter, 32kHz–106 kHz << 22 psec

D/A CONVERTERParameter Value UnitsResolution 24 bitsConversion system Delta-SigmaSample Rates 32–106 kHzRelative THD+N, S/(N+D)

–0.5 dBFS input –100 dBDynamic range

–60 dB, Unweighted 112 dBChannel Separation >120 dBFrequency Response (10Hz–20 kHz)

Gain ±0.15 dBPhase << 1.0 degrees

Maximum Output Level 28 dBu

DIGITAL SIGNAL PROCESSINGUV22HR Amplitude

16 bits –84 dB20 bits –108 dB

MeteringAccuracy (CAL mode) ± 0.1 dB Over Detection 1–4 consecutive 0 dBFS readings

(user-definable)

SYSTEMAC line voltage 100, 120, 220, 240 vac (set internally)Fusing 5 x 20 mm, 250V 100/120V~, 800mA, T (Slow Blow)

220/240V~, 400mA, T (Slow Blow)Power 25 WattsSize (w, h, d) 19 in, 1.75 in (1U), 14.25 inWeight 12.5 lb (5.8 kg)

The Specifications above, and other information provided in this brochure,are subject to change without notice. Apogee Electronics Corporationreserves the right to make design changes without prior warning. Apogee,UV22, Soft Limit, AMBus, Clocked by Apogee, Apogee Bit-Splitting and the“96k” device are trademarks or registered trademarks of Apogee ElectronicsCorporation. Other trademarks are the property of their respective owners.

“x2Fs” LED: Indicates that the unitis in “fast” mode (88.2/96 kHz sampling).

Power Switch – push on, push offOn power-up, the PSX performs a self-test andthen recalled settings illuminate. To set theunit to its factory defaults (other than DIPswitch settings), hold the OUTPUT RES buttondown during power-up, until the lights comeon.

Optical Output Selection: Press thebutton to toggle the Optical output betweenADAT and S/PDIF.

AES/EBU Auxiliary Output: TheAux Out is a digital AES/EBU output pro-viding a “clean feed” from the system, egfor high accuracy metering. It deliversthe same signal as is present at the D/Ainput, and can act as an additional paral-lel AES/EBU output, or it can be used torecord, for example, a full-resolution 24-bit mix while the other outputs are deliv-ering 16- or 20-bit feeds with UV22.

Main AES/EBU inputs: The two inputscan be individually selected from the frontpanel. Both connectors are used for 88.2/96kHz operation.

S/PDIF Coaxial Input: An industry-standard RCA connector provides S/PDIFcoaxial input capability.

A/D Sync This button determines the SyncSource for the A/D section of the PSX-100.Repeated button-presses cycle through Crystal(44.1/88.2 or 48/96 kHz), Word Clock, digitalinput or video (the latter only with sync cardoption). Hold the button down for 2 secondsto engage or disengage “fast” mode (“2xFs”light goes on/off).

Soft Limit: Apogee’s proprietary Soft Limitcircuitry enables you to get maximum digitallevel without risking digital “overs”.

Optical I/O: This interface can be front-panel selected to offer either ADAT or S/PDIFoptical protocols. In ADAT mode, ABS tracksets (including stereo at 96kHz on a 16-bit48kHz machine!) may be output for recording,and recombined for replay via the D/A ortransfer to other digital outputs.

Analog Inputs & Outputs: Line-level analog I/O on XLR connectors. DIPswitches allow the selection of pin 2 or 3hot, and the inputs and outputs can beset separately for either professional or consumer level operation.

Dual AES/EBU Outputs: XLR connectorsdeliver the two main 2-channel AES/EBU out-puts. Both connectors are used for 88.2/96kHz operation.

Mute Left/Right: Pressing the button tog-gles the mute function on/off. The LED indi-cates that the channel is MUTED.

Output Res: Repeated pressing of this but-ton cycles through the available word lengthoptions – 20 or 16-bit with UV22 (44.1/48 only),or full 24-bit.

The Apogee PSX-100 — Front and rear panels

MDM Input Selection: When using thePSX-100 with modular digital multitracks,select the pair of tracks you want to listen to(or the set of tracks for replaying a bit-splitsource).

AC Power Input: The AC input volt-age is set internally. Check the voltagesetting is correct before operation, andkeep the rear panel label up-to-date.

TDIF Interface: A DB-25 connector provides interfacing with TDIF devices such asTascam modular digital multitracks, consoles,DAWs and digital audio PC cards which feature this kind of interfacing.

D/A Input: The D/A can be set to monitoreither AES input (both are used in “fast”mode), or any of the other interfaces, plus theoutput of the A/D. Press the button repeatedlyto cycle through active inputs.

Apogee Bit-Splitting (ABS): Write 24-bitchannels to pairs of 16-bit 44.1/48 kHz tracks(PaqRat mode) or use all eight tracks of a 16-bit 44.1/48 recorder to capture stereo 24-bitsignals at 88.2/96kHz sampling.

DIP Switches for Option Selection: A10-way DIP switch allows “set-once” parame-ters to be determined, such as analog input/output level; pin 2/3 hot; 2-second or infinite“over” indication; “over” definition (1-4 con-secutive FS); ABS enable on AES input (forPCM-800 etc); and special sync parameters.

Digital Copy: In this mode, the selecteddigital input is delivered to all the PSX-100’soutputs, digital and analog. Ideal for formatconversion, adding UV22 to existing programmaterial, and for maximum D/A flexibility.

Level Trim: Screwdriver adjustment ofA/D and D/A analog levels forcalibration and gain-structure alignment.USe in conjunction with CAL mode.

S/PDIF Coaxial Output: An industry-standard RCA connector provides S/PDIFcoaxial output capability. At high sample rates(88.2/96kHz), this socket provides a 44.1/48kHzS/PDIF output derived from alternate samples.

Word Clock In & Out: BNC connectorsallow word clock interfacing. In addition, theWC input socket can act as a video input whenthe video option card is installed.

Meter: Press the button to toggle betweenmetering the A/D or the D/A.

D/A Sync: Indicates the sync source for theD/A – refers to the selected input.

s, showing controls, indicators and connectors.

Top Cover Label: The label shown below appears on the rear of the top cover of the PSX-100, and is read from the front of the unit. Itindicates the connectors that appear directly beneath the labels, as well as CE information and a block diagram of the A/D and D/A sections.