PSEG Internal Use Only Page 1 of 1
PSEG NUCLEAR L.L.C.SALEM/OPERATIONS
S2.OP-AR.ZZ-0003(Q) - REV. 17
OVERHEAD ANNUNCIATORS WINDOW C
Ë Biennial Review Performed: Yes ____ No T Ë DCP Packages and Affected Document Numbers incorporated into this revision: NoneË OTSC(s) were incorporated into this revision: NoneË OPEX(s) were incorporated into this revision: None
REVISION SUMMARY:
Ë Pg. 45, OHA C-38, CFCU Leak Detection High, Step 3.5.D - Added stepINITIATE SC.OP-DG.SW-0005, Service Water Spill Response in Containment. (70103767)
IMPLEMENTATION REQUIREMENTS Effective Date: 01/21/10
‚ None
S2.OP-AR.ZZ-0003(Q)
Salem 2 Page 1 of 57 Rev. 17
OVERHEAD ANNUNCIATORS WINDOW C
TABLE OF CONTENTS
SECTION PAGE
Table of Contents . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1
Window C Overview . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3
Text . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4
WINDOW SECTION
C-1 GAS ANLY TRBL . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4
C-2 CNTMT SUMP PMP START . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5
C-3 21 CC HX IN TEMP HI . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6
C-4 21 CFCU AIRFLO TRBL . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7
C-5 21 CFCU WTRFLO TRBL . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 8
C-6 CNTMT PRESS HI-HI . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 9
C-7 21 H2 RECOMB TRBL . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 10
C-8 N A CNTMT ISOL ACT . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 11
C-9 104 PNL TRBL . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 12
C-10 CNTMT SUMP OVRFLO . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 13
C-11 22 CC HX IN TEMP HI . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 14
C-12 22 CFCU AIRFLO TRBL . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 15
C-13 22 CFCU WTRFLO TRBL . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 16
C-14 CNTMT PRESS HI . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 17
C-15 22 H2 RECOMB TRBL . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 18
C-16 N B CNTMT ISOL ACT . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 19
C-17 21-23 CVCS HUT LVL HI . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 20
C-18 RX SUMP OVRFLO . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 21
C-19 SFP TEMP HI . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 23
C-20 23 CFCU AIRFLO TRBL . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 25
C-21 23 CFCU WTRFLO TRBL . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 26
C-22 CNTMT SPRY ACT . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 27
S2.OP-AR.ZZ-0003(Q)
Salem 2 Page 2 of 57 Rev. 17
TABLE OF CONTENTS (Continued)
WINDOW SECTION PAGE
C-23 CNTMT H2 LVL HI . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 28
C-24 SPARE . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 29
C-25 BA EVAP TRBL . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 30
C-26 21 RHR SUMP OVRFLO . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 31
C-27 SFP LVL HI . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 32
C-28 24 CFCU AIRFLO TRBL . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 33
C-29 24 CFCU WTRFLO TRBL . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 34
C-30 CFCU LK DET HI-HI . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 35
C-31 SPARE . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 37
C-32 SPARE . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 38
C-33 RWST/PWST OVRFLO . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 39
C-34 22 RHR SUMP OVRFLO . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 40
C-35 SFP LVL LO . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 41
C-36 25 CFCU AIRFLO TRBL . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 42
C-37 25 CFCU WTRFLO TRBL . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 43
C-38 CFCU LK DET HI . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 44
C-39 SPARE . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 46
C-40 SPARE . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 47
C-41 SPARE . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 48
C-42 SPARE . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 49
C-43 SPARE . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 50
C-44 SPARE . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 51
C-45 SPARE . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 52
C-46 PERSONNEL ACCESS DOOR OPEN . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 53
C-47 SPARE . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 54
C-48 SPARE . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 55
References . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 56
S2.OP-AR.ZZ-0003(Q)
Salem 2 Page 3 of 57 Rev. 17
C
WA
STE
DIS
POSA
LLE
AK
DET
ECT
AU
XC
OO
LIN
GC
ON
TAIN
MEN
T
1
1
GA
S A
NLY
TRB
L
M
2
CN
TMT
SUM
P PM
PST
AR
T
3
21 C
C H
XIN
TEM
PH
I
4
21 C
FCU
AIR
FLO
TRB
L
5
21 C
FCU
WTR
FLO
TRB
L
6
CN
TMT
PRES
SH
I - H
I
7
21 H
2R
ECO
MB
TRB
L
8
N A
CN
TMT
ISO
LA
CT
8
9
9
104
PNL
TRB
L
10
CN
TMT
SUM
PO
VR
FLO
11
22 C
C H
XIN
TEM
PH
I
12
22 C
FCU
AIR
FLO
TRB
L
13
22 C
FCU
WTR
FLO
TRB
L
14
CN
TMT
PRES
SH
I
15
22 H
2R
ECO
MB
TRB
L
16
N B
CN
TMT
ISO
LA
CT
16
17
17
21 -
23 C
VC
SH
UT
LVL
HI
M
18
RX
SUM
PO
VR
FLO
19
SFP
TEM
PH
I
20
23 C
FCU
AIR
FLO
TRB
L
21
23 C
FCU
WTR
FLO
TRB
L
22
CN
TMT
SPR
YA
CT
23
CN
TMT
H2 L
VL
HI
24
24
25
25
BA
EV
AP
TRB
L
26
21 R
HR
SUM
PO
VR
FLO
27
SFP
LVL
HI
28
24 C
FCU
AIR
FLO
TRB
L
29
24 C
FCU
WTR
FLO
TRB
L
30
CFC
ULK
DET
HI -
HI
M
3132
32
3333
RW
ST /
PWST
OV
RFL
O
34
22 R
HR
SUM
PO
VR
FLO
35
SFP
LVL
LO
36
25 C
FCU
AIR
FLO
TRB
L
37
25 C
FCU
WTR
FLO
TRB
L
38
CFC
ULK
DET
HI
M
3940
40
41
4142
4344
4546
PER
SON
NEL
AC
CES
SD
OO
R O
PEN
4748
48
S2.OP-AR.ZZ-0003(Q)
Salem 2 Page 4 of 57 Rev. 17
ALARM
C-11
GAS ANLYTRBL
M
DEVICES: N/A
SETPOINT: N/A
1.0 CAUSE(S):
1.1 Cover Gas Low Flow
1.2 AC Power failure
1.3 Hydrogen Low
1.4 DC Power Failure
1.5 WGDT Low Flow
1.6 Recorder Trouble
1.7 Oxygen High/Low
2.0 AUTOMATIC ACTION:
None
3.0 OPERATOR ACTIONS:
3.1 SEND Operator to Waste Disposal Gas Analyzer PNL 110 to determine cause of alarm.
3.2 GO TO S2.OP-AR.WG-0001(Q), Waste Disposal Gas Analyzer PNL 110.
Page 1 of 1 C-1References:
S2.OP-AR.ZZ-0003(Q)
Salem 2 Page 5 of 57 Rev. 17
ALARM
C-22
CNTMTSUMP PMP
START
DEVICES: N/A
SETPOINT: N/A
1.0 CAUSE(S):
21 or 22 Containment Sump Pumps started
2.0 AUTOMATIC ACTION:
None
3.0 OPERATOR ACTIONS:
3.1 IF any indication of an RCS leak or an interconnecting ECCS leak affecting RCS inventory,THEN GO TO S2.OP-AB.RC-0001(Q), Reactor Coolant System Leak.
3.2 DETERMINE a leakrate IAW S2.OP-SO.RC-0004(Q),Identifying and Measuring Leakage.
A. IF leakrate is $ 1 gpm,THEN REFER to Technical Specifications.
B. IF leakrate is trending up,THEN:
1. SEND an Operator into Containment to determine source of leak.
2. INITIATE a NOTF IAW LS-AA-120, Issue Identification and Screening Process
3.3 MONITOR the WHUT levels.
Page 1 of 1 C-2References: Dwg. 220972
S2.OP-AR.ZZ-0003(Q)
Salem 2 Page 6 of 57 Rev. 17
ALARM
C-33
21 CC HXIN TEMP
HI
DEVICES: 2TIC627A
SETPOINT: $ 170°F
1.0 CAUSE(S):
Inlet temperature is $ 170°F
2.0 AUTOMATIC ACTION:
None
3.0 OPERATOR ACTIONS:
3.1 IF alarm is due to loss of Service Water pressure,THEN GO TO S2.OP-AB.SW-0001(Q), Loss of Service Water Header Pressure.
3.2 IF alarm is due to loss of Component Cooling Water,THEN GO TO S2.OP-AB.CC-0001(Q), Component Cooling Abnormality.
3.3 SEND an operator to perform the following:
Ë INVESTIGATE the cause of the alarm.
Ë ALIGN CCHXs as directed IAW S2.OP-SO.CC-0002(Q), 21 & 22 Component Cooling Heat Exchanger Operation.
3.5 REFER to Technical Specifications 3.7.3 and 3.7.4.
Page 1 of 1 C-3References: Dwg. 205331, 211522
S2.OP-AR.ZZ-0003(Q)
Salem 2 Page 7 of 57 Rev. 17
ALARM
C-44
21 CFCUAIRFLO
TRBL
DEVICES: N/A
SETPOINT: N/A
1.0 CAUSE(S):
1.1 Roughing Filter Dampers not fully OPEN
1.2 HEPA Filter Inlet Damper not fully CLOSED
1.3 HEPA Filter Outlet Damper not fully CLOSED
2.0 AUTOMATIC ACTION:
None
3.0 OPERATOR ACTIONS:
3.1 IF 21 Containment Fan Coil Unit is operating in low speed,THEN no further Operator action is required.
3.2 VERIFY positions of 21 Containment Fan Coil Filter Dampers
on Control Console bezels.
3.3 IF damper malfunction is indicated,THEN:
A. STOP 21 Containment Fan Coil Unit.
B. INITIATE a NOTF IAW LS-AA-120, Issue Identification and Screening Process.
3.4 REFER to Technical Specification 3.6.2.3.
Page 1 of 1 C-4References: Dwg. 205338, 203568
S2.OP-AR.ZZ-0003(Q)
Salem 2 Page 8 of 57 Rev. 17
ALARM
C-5
5
21 CFCUWTRFLO
TRBL
DEVICES: N/A
SETPOINT: N/A
1.0 CAUSE(S):
Any SW Valve misaligned with the CFCU running:
‚ 21SW58, 21 FAN COIL UNIT INLET WATER VALVE not fully OPEN
‚ 21SW72, 21 FAN COIL UNIT OUTLET WATER VALVE not fully OPEN
‚ 21SW223, 21 FAN COIL UNIT OUTLET WATER FLOW CONTROL VALVE is CLOSED
2.0 AUTOMATIC ACTION:
None
3.0 OPERATOR ACTIONS:
3.1 CONFIRM alarm by observing flow indication on 21 CFCU bezel.
3.2 OPEN the following valves:
A. 21SW58, 21 FAN COIL UNIT INLET WATER VALVE
B. 21SW72, 21 FAN COIL UNIT OUTLET WATER VALVE
3.3 IF a valve malfunction is suspected,THEN:
A. STOP 21 Containment Fan Coil Unit.
B. INITIATE a NOTF IAW LS-AA-120, Issue Identification and Screening Process
C. REFER to Technical Specification 3.6.2.3
Page 1 of 1 C-5References: Dwg. 205342, 203570
S2.OP-AR.ZZ-0003(Q)
Salem 2 Page 9 of 57 Rev. 17
ALARM
C-66
CNTMTPRESSHI-HI
DEVICES: 2PC948A, 2PC948B, 2PC948C, 2PC948G
SETPOINT: $ 15 psig
1.0 CAUSE(S):
Containment pressure channel $ 15 psig.
2.0 AUTOMATIC ACTION:
None
3.0 OPERATOR ACTIONS:
3.1 CONFIRM alarm by verifying indication.
3.2 IF alarm is due to testing,THEN no further action is required.
3.3 IF instrument failure is suspected,THEN:
A. REMOVE affected channel from service IAW S2.OP-SO.RPS-0005(Q),Placing Containment Pressure Channel In Tripped Condition.
B. INITIATE a NOTF IAW LS-AA-120, Issue Identification and Screening Process
3.4 REFER to Technical Specification 3.3.2.1.
Page 1 of 1 C-6References: Dwg. 221057
S2.OP-AR.ZZ-0003(Q)
Salem 2 Page 10 of 57 Rev. 17
ALARM
C-77
21 H2RECOMB
TRBL
DEVICES: N/A
SETPOINT: # 350V input voltage
1.0 CAUSE(S):
Input voltage is # 350V
2.0 AUTOMATIC ACTION:
None
3.0 OPERATOR ACTIONS:
3.1 IF alarm is due to testing,THEN no further Operator action is required.
3.2 ENSURE CLOSED breaker 2AX1AX15X at 2A 460V Vital Bus.
3.3 REFER to Technical Specification 3.6.4.2.
3.4 INITIATE a NOTF IAW LS-AA-120, Issue Identification and Screening Process
Page 1 of 1 C-7References: Dwg. 203653
S2.OP-AR.ZZ-0003(Q)
Salem 2 Page 11 of 57 Rev. 17
ALARM
C-88
N ACNTMT ISOL
ACT
DEVICES: N/A
SETPOINT: N/A
1.0 CAUSE(S):
1.1 Containment Isolation Phase A manual actuation
1.2 Safety Injection signal
2.0 AUTOMATIC ACTION:
Phase A valves displayed on Panel 2RP4 CLOSE.
3.0 OPERATOR ACTIONS:
3.1 IF alarm is due to an SI,THEN GO TO 2-EOP-TRIP-1, Reactor Trip or Safety Injection.
3.2 CONFIRM alarm by observing Panel 2RP4 or actual valve position indicationon Control Room Console.
3.3 IF alarm is due to a failure,
THEN:
A. EVALUATE components affected.
B. INITIATE a NOTF IAW LS-AA-120, Issue Identification and Screening Process.
C. When notified of corrective action completion by Maintenance,RESET the alarm.
3.4 REFER to Technical Specification 3.3.2.1.
Page 1 of 1 C-8References: Dwg. 221057, 232015
S2.OP-AR.ZZ-0003(Q)
Salem 2 Page 12 of 57 Rev. 17
ALARM
C-99
104 PNL
TRBL
DEVICES: N/A
SETPOINT: N/A
1.0 CAUSE(S):
An alarm on Panel 104, Waste Disposal-Boron Recycle Panel
2.0 AUTOMATIC ACTION:
None
3.0 OPERATOR ACTIONS:
3.1 SEND an Operator to Panel 104, Waste Disposal-Boron Recycle Panelto perform the following:
A. DETERMINE cause of the alarm.
B. INITIATE corrective action IAW S2.OP-AR.ZZ-0016(Q), Panel 104 Alarms.
Page 1 of 1 C-9References: Dwg. 226513
S2.OP-AR.ZZ-0003(Q)
Salem 2 Page 13 of 57 Rev. 17
ALARM
C-10
10
CNTMTSUMP
OVRFLO
DEVICES: 2LD2067
SETPOINT: $ 75 feet 1 inch 1.0 CAUSE(S):
Containment Sump level $ 75 feet 1 inch 2.0 AUTOMATIC ACTION:
None 3.0 OPERATOR ACTIONS:
3.1 IF Containment Sump Overflow is due to "N A Isolation" THEN RETURN to procedure in effect.
3.2 ENSURE OPEN the following valves:
A. 2WL16, CONT SUMP DISCH TO WHUT
B. 2WL17, CONT SUMP DISCH TO WHUT
3.3 IF Containment Sump Pump(s) failed to start,THEN VERIFY CLOSED:
Ë Breaker 2GY1AX6J, 21 Containment Sump Pump
Ë Breaker 2EY3AX6J, 22 Containment Sump Pump
3.4 ENSURE Containment Sump Pumps have started.
3.5 IF any indication of an RCS leak or an interconnecting ECCS leak
affecting RCS inventory,THEN GO TO S2.OP-AB.RC-0001(Q), Reactor Coolant System Leak.
3.6 DETERMINE a leakrate IAW S2.OP-ST.RC-0008(Q), RCS Water Inventory Balance.
A. IF leakrate is trending up,
THEN SEND an Operator into Containment to determine source of leak.
B. IF leakrate is $ 1 gpm,THEN REFER to Technical Specifications.
Page 1 of 1 C-10
References: Dwg. 205326, 220972, 211514
S2.OP-AR.ZZ-0003(Q)
Salem 2 Page 14 of 57 Rev. 17
ALARM
C-1111
22 CC HXIN TEMP
HI
DEVICES: 2TIC627B
SETPOINT: $ 170°F
1.0 CAUSE(S):
Inlet temperature is $ 170°F
2.0 AUTOMATIC ACTION:
None
3.0 OPERATOR ACTIONS:
3.1 IF alarm is due to loss of Service Water pressure,THEN GO TO S2.OP-AB.SW-0001(Q), Loss of Service Water Header Pressure.
3.2 IF alarm is due to loss of Component Cooling Water,
THEN GO TO S2.OP-AB.CC-0001(Q), Component Cooling Abnormality.
3.3 SEND an operator to perform the following:
Ë INVESTIGATE the cause of the alarm.
Ë ALIGN CCHXs as directed IAW S2.OP-SO.CC-0002(Q), 21 & 22 Component Cooling Heat Exchanger Operation.
3.5 REFER to Technical Specifications 3.7.3 and 3.7.4.
Page 1 of 1 C-11References: Dwg. 205331, 211523
S2.OP-AR.ZZ-0003(Q)
Salem 2 Page 15 of 57 Rev. 17
ALARM
C-1212
22 CFCUAIRFLO
TRBL
DEVICES: N/A
SETPOINT: N/A
1.0 CAUSE(S):
1.1 Roughing Filter Dampers not fully OPEN
1.2 HEPA Filter Inlet Damper not fully CLOSED
1.3 HEPA Filter Outlet Damper not fully CLOSED
2.0 AUTOMATIC ACTION:
None
3.0 OPERATOR ACTIONS:
3.1 IF 22 Containment Fan Coil Unit is operating in low speed,THEN no further Operator action is required.
3.2 ENSURE the positions of 22 Containment Fan Coil Filter Dampers
on the Control Console bezels.
3.3 IF damper malfunction is indicated,THEN:
A. STOP 22 Containment Fan Coil Unit.
B. INITIATE a NOTF IAW LS-AA-120, Issue Identification and Screening Process
3.4 REFER to Technical Specification 3.6.2.3.
Page 1 of 1 C-12References: Dwg. 205338, 203572
S2.OP-AR.ZZ-0003(Q)
Salem 2 Page 16 of 57 Rev. 17
ALARM
C-1313
22 CFCUWTRFLO
TRBL
DEVICES: N/A
SETPOINT: N/A
1.0 CAUSE(S):
Any SW Valve misaligned with the CFCU running:
‚ 22SW58, 22 FAN COIL UNIT INLET WATER VALVE not fully OPEN
‚ 22SW72, 22 FAN COIL UNIT OUTLET WATER VALVE not fully OPEN
‚ 22SW223, 22 FAN COIL UNIT OUTLET WATER FLOW CONTROL VALVE,is CLOSED
2.0 AUTOMATIC ACTION:
None
3.0 OPERATOR ACTIONS:
3.1 CONFIRM alarm by observing flow indication on 22 CFCU bezel.
3.2 ENSURE OPEN the following valves:
A. 22SW58, 22 FAN COIL UNIT INLET WATER VALVE
B. 22SW72, 22 FAN COIL UNIT OUTLET WATER VALVE
3.3 IF a valve malfunction is suspected,THEN:
A. STOP 22 Containment Fan Coil Unit.
B. INITIATE a NOTF IAW LS-AA-120, Issue Identification and Screening Process
3.4 REFER to Technical Specification 3.6.2.3.
Page 1 of 1 C-13References: Dwg. 205342, 203574
S2.OP-AR.ZZ-0003(Q)
Salem 2 Page 17 of 57 Rev. 17
ALARM
C-1414
CNTMTPRESS
HI
DEVICES: 2PC948D, 2PC948E, 2PC948F
SETPOINT: $ 4 psig
1.0 CAUSE(S):
Containment pressure channel $ 4 psig
2.0 AUTOMATIC ACTION:
None
3.0 OPERATOR ACTIONS:
3.1 CONFIRM alarm by verifying indication.
3.2 IF alarm is due to testing,THEN no further action is required.
3.3 IF instrument failure is suspected,THEN:
A. REMOVE affected channel from service IAW S2.OP-SO.RPS-0005(Q),Placing Containment Pressure Channel In Tripped Condition.
B. INITIATE a NOTF IAW LS-AA-120, Issue Identification and Screening Process
3.4 REFER to Technical Specification 3.3.2.1.
Page 1 of 1 C-14References: Dwg. 221057
S2.OP-AR.ZZ-0003(Q)
Salem 2 Page 18 of 57 Rev. 17
ALARM
C-1515
22 H2RECOMB
TRBL
DEVICES: N/A
SETPOINT: # 350V input voltage
1.0 CAUSE(S):
Input voltage is # 350V
2.0 AUTOMATIC ACTION:
None
3.0 OPERATOR ACTIONS:
3.1 IF alarm is due to testing,THEN no further action is required.
3.2 ENSURE CLOSED breaker 2BX1AX15X on 2B 460V Vital Bus
for No. 22 Hydrogen Recombiner
3.3 REFER to Technical Specification 3.6.4.2.
3.4 INITIATE a NOTF IAW LS-AA-120, Issue Identification and Screening Process.
Page 1 of 1 C-15References: Dwg. 203654
S2.OP-AR.ZZ-0003(Q)
Salem 2 Page 19 of 57 Rev. 17
ALARM
C-1616
N BCNTMT ISOL
ACT
DEVICES: 2PC948A, 2PC948B, 2PC948C, 2PC948G
SETPOINT: $ 15 psig
1.0 CAUSE(S):
1.1 Two out of four Containment pressure channels are $ 15 psig
1.2 Manual Actuation
2.0 AUTOMATIC ACTION:
2.1 N B valves on Panel 2RP4 CLOSE.
2.2 Containment Spray Valves on Panel 2RP4 OPEN
2.3 Containment Spray Pumps START (if SEC permissive exists)
3.0 OPERATOR ACTIONS:
3.1 CONFIRM alarm by verifying coincidence on Panel 2RP4OR valve indications on Control Console.
3.2 IF Containment pressure is $ 15 psig,THEN:
A. TRIP the Reactor.
B. GO TO 2-EOP-TRIP-1, Reactor Trip or Safety Injection.
3.3 IF Containment pressure is # 15 psig,THEN:
A. Attempt to RESET AND OPEN the Phase B Containment Isolation Valves.
B. IF unable to reset Phase B Containment Isolation,THEN GO TO S2.OP-AB.RCP-0001(Q), RCP Abnormality,for loss of CCW flow to all RCP Motors.
Page 1 of 1 C-16References: Dwg. 221057, 232016
S2.OP-AR.ZZ-0003(Q)
Salem 2 Page 20 of 57 Rev. 17
ALARM
C-1717
21-23 CVCSHUT LVL
HIM
DEVICES: 2LT167, 2LT168, 2LT170
SETPOINT: $ 90%
1.0 CAUSE(S):
Any CVCS HUT level $ 90%
2.0 AUTOMATIC ACTION:
None
3.0 OPERATOR ACTIONS:
3.1 DETERMINE which CVCS HUT is causing the alarm from the Annunciator CRT:
CRT Point Description
173 21 CVCS HOLDUP TANK LEVEL HIGH
180 22 CVCS HOLDUP TANK LEVEL HIGH
188 23 CVCS HOLDUP TANK LEVEL HIGH
3.2 SEND an operator to PLACE an unaffected tank in service IAWS2.OP-SO.CVC-0004(Q), CVCS Holdup Tank System Operations.
Page 1 of 1 C-17References: Dwg. 205329
S2.OP-AR.ZZ-0003(Q)
Salem 2 Page 21 of 57 Rev. 17
ALARM
C-1818
RXSUMP
OVRFLO
DEVICES: 2LD7752
SETPOINT: $ 54 feet
1.0 CAUSE(S):
Reactor Sump level $ 54 feet
2.0 AUTOMATIC ACTION:
None
3.0 OPERATOR ACTIONS:
3.1 IF in Modes 1-5,THEN:
A. IF Reactor Sump Pump has not started,THEN VERIFY CLOSED breaker 2EY3AX6G for 2 Reactor Sump Pump
B. ENSURE Reactor Sump Pump has started.
C. IF any indication of an RCS leak or an interconnecting ECCS leak affecting RCS inventory,THEN GO TO S2.OP-AB.RC-0001(Q), Reactor Coolant System Leak.
D. DETERMINE a leakrate IAW S2.OP-ST.RC-0008(Q),RCS Water Inventory Balance.
E. INITIATE a NOTF IAW LS-AA-120, Issue Identification and Screening Process, as required.
(Continued)
Page 1 of 2 C-18
S2.OP-AR.ZZ-0003(Q)
Salem 2 Page 22 of 57 Rev. 17
3.2 IF in Mode 6,THEN:
A. IF Reactor Cavity level is decreasing,THEN GO TO S2.OP-AB.FUEL-0002(Q),Loss of Refueling Cavity or Spent Fuel Pool Level.
B. IF Reactor Cavity level is stable,THEN:
1. VERIFY CLOSED breaker 2EY3AX6G for 2 Reactor Sump Pump.
2. SEND an operator to determine the source of the leakage.
3. INITIATE a NOTF IAW LS-AA-120, Issue Identification and Screening Process, as required.
Page 2 of 2 C-18References: Dwg. 205326, 220972, 240698
S2.OP-AR.ZZ-0003(Q)
Salem 2 Page 23 of 57 Rev. 17
ALARM
C-1919
SFPTEMP
HI
DEVICES: 2TIC651
SETPOINT: 125°F OR a temporary alarm setpoint may be in effect to supportrefueling outages (specifically reactor core off-loads).
NOTE
This alarm is expected during refueling outages during core off-load. The alarm setpoint mayhave to be raised to meet the commitment to maintain a loss of SFP cooling alarm.
1.0 CAUSE(S):
1.1 Spent Fuel Pit temperature $125°F.
1.2 Spent Fuel Pit temperature is greater than the temporary alarm setpoint during refueling.
2.0 AUTOMATIC ACTION:
None
3.0 OPERATOR ACTIONS:
3.1 SEND operator to validate cause of alarm.
3.2 REMOVE the Spent Fuel Demineralizer from service IAW S2.OP-SO.SF-0002(Q),Spent Fuel Cooling System Operation prior to reaching a Spent Fuel Pit temperature(TIC651) of 130°F.
(continued on next page)Page 1 of 2 C-19
S2.OP-AR.ZZ-0003(Q)
Salem 2 Page 24 of 57 Rev. 17
3.0 OPERATOR ACTIONS (continued)
3.3 IF the Spent Fuel Pit temperature is >125°FAND reactor core off-load is either in progress or completely off-loaded,THEN:
A. INITIATE a continuous watch to monitor SFP temperature until the alarm setpoint is adjusted, as applicable, and the alarm is clear.
1. INITIATE Temporary readings IAW SH.OP-DL.ZZ-0027 AND RECORD Spent Fuel Pit temperature (TIC651) every half hour until alarm setpoint has been changed, AND the Spent Fuel Demineralizer has been removed from service.
2. IF the Alarm is adjusted,AND the Spent Fuel Demineralizer is out of service,THEN RECORD the Spent Fuel Pit temperature (TIC651) every four hours until the alarm setpoint has been returned to normal (125°F).
B. INITIATE a NOTF to Maintenance to adjust the alarm setpointas provided by Outage Engineering (Refer to S-C-SF-MDC-1800).
3.4 IF SFP cooling cannot be maintained below the alarm setpoint(
S2.OP-AR.ZZ-0003(Q)
Salem 2 Page 25 of 57 Rev. 17
ALARM
C-2020
23 CFCUAIRFLO
TRBL
DEVICES: N/A
SETPOINT: N/A
1.0 CAUSE(S):
1.1 Roughing Filter Dampers not fully open
1.2 HEPA Filter Inlet Damper not fully closed
1.3 HEPA Filter Outlet Damper not fully closed
2.0 AUTOMATIC ACTION:
None
3.0 OPERATOR ACTIONS:
3.1 IF 23 Containment Fan Coil Unit is operating in low speed,THEN no further action is required.
3.2 VERIFY positions of 23 Containment Fan Coil Filter Dampers
on Control Console bezels.
3.3 IF damper malfunction is indicated,THEN:
A. STOP 23 Containment Fan Coil Unit.
B. INITIATE a NOTF IAW LS-AA-120, Issue Identification and Screening Process
3.4 REFER to Technical Specification 3.6.2.3.
Page 1 of 1 C-20References: Dwg. 205338, 203576
S2.OP-AR.ZZ-0003(Q)
Salem 2 Page 26 of 57 Rev. 17
ALARM
C-2121
23 CFCUWTRFLO
TRBL
DEVICES: N/A
SETPOINT: N/A 1.0 CAUSE(S):
Any SW Valve misalignment with the CFCU running:
‚ 23SW58, 23 FAN COIL UNIT INLET WATER VALVE not fully OPEN
‚ 23SW72, 23 FAN COIL UNIT OUTLET WATER VALVE not fully OPEN
‚ 23SW223, 23 FAN COIL UNIT OUTLET WATER FLOW CONTROL VALVE,is CLOSED
2.0 AUTOMATIC ACTION:
None
3.0 OPERATOR ACTIONS:
3.1 CONFIRM alarm by observing flow indication on 23 CFCU bezel.
3.2 ENSURE OPEN the following valves:
A. 23SW58, 23 FAN COIL UNIT INLET WATER VALVE
B. 23SW72, 23 FAN COIL UNIT OUTLET WATER VALVE
3.3 IF a valve malfunction is suspected,THEN:
A. STOP 23 Containment Fan Coil Unit.
B. INITIATE a NOTF IAW LS-AA-120, Issue Identification and Screening Process
3.4 REFER to Technical Specification 3.6.2.3.
Page 1 of 1 C-21 References: Dwg. 205342, 203578
S2.OP-AR.ZZ-0003(Q)
Salem 2 Page 27 of 57 Rev. 17
ALARM
C-2222
CNTMTSPRYACT
DEVICES: 2PC948A, 2PC948B, 2PC948C, 2PC948G
SETPOINT: $ 15 psig
1.0 CAUSE(S):
1.1 Two out of four Containment pressure channels are $ 15 psig
1.2 Manual actuation
2.0 AUTOMATIC ACTION:
2.1 Containment Spray Valves OPEN
2.2 Containment Spray Pumps START (if SEC permissives exists)
2.3 Containment Isolation Phase B
2.4 Containment Ventilation Isolation (manual signal only)
2.5 Main Steamline Isolation (automatic signal only)
3.0 OPERATOR ACTIONS:
3.1 IF alarm due to testing,THEN no further Operator action required.
3.2 CONFIRM alarm by verifying coincidence on Panel 2RP4AND Main Control Console indications.
3.3 GO TO 2-EOP-TRIP-1, Reactor Trip or Safety Injection.
Page 1 of 1 C-22References: Dwg. 221057
S2.OP-AR.ZZ-0003(Q)
Salem 2 Page 28 of 57 Rev. 17
ALARM
C-2323
CNTMTH2 LVL
HI
DEVICES:
SETPOINT: $ 2% hydrogen
1.0 CAUSE(S):
Hydrogen concentration in Containment atmosphere is $ 2%
2.0 AUTOMATIC ACTION:
None
3.0 OPERATOR ACTIONS:
3.1 IF alarm is due to testing,THEN no further Operator action is required.
3.2 CONFIRM alarm by observing Control Room charts and H2 monitors (2RP5).
3.3 IF alarm is valid,THEN:
A. NOTIFY Chemistry for a confirming sample.
B. PLACE Recombiner in service IAW S2.OP-SO.CAN-0001(Q),Hydrogen Recombiner Operation.
C. REFER to Event Classification Guide.
3.4 REFER to Technical Specifications 3.6.4.1.
Page 1 of 1 C-23References: Dwg. 252310
S2.OP-AR.ZZ-0003(Q)
Salem 2 Page 29 of 57 Rev. 17
ALARM
C-2424
SPARE
DEVICES:
SETPOINT:
Page 1 of 1 C-24References: Dwg.
S2.OP-AR.ZZ-0003(Q)
Salem 2 Page 30 of 57 Rev. 17
ALARM
C-2525
BA EVAPTRBL
DEVICES: N/A
SETPOINT: N/A
1.0 CAUSE(S):
An alarm at Panel 301, Gas Stripper & Boron Concentrate Panel
2.0 AUTOMATIC ACTION:
None
3.0 OPERATOR ACTIONS:
3.1 SEND an Operator to Panel 301-2, Gas Stripper & Boron Concentrate Panel,to perform the following:
A. DETERMINE cause of the alarm.
B. INITIATE corrective action.
Page 1 of 1 C-25References: Dwg. 222875
S2.OP-AR.ZZ-0003(Q)
Salem 2 Page 31 of 57 Rev. 17
ALARM
C-2626
21 RHRSUMP
OVRFLO
DEVICES: 2LD7753, 2LD7754
SETPOINT: $ 42 feet
1.0 CAUSE(S):
21 RHR Sump level $ 42 feet
2.0 AUTOMATIC ACTION:
None
3.0 OPERATOR ACTIONS:
3.1 IF RHR Sump Pumps have not started,THEN VERIFY CLOSED breakers:
Ë 2CY2AX5A, #21 RHR Sump Pump
Ë 2BY2AX5A, #22 RHR Sump Pump
3.2 SEND an Operator to the RHR Pump room and 84 ft elevation to determine source of leak.
3.3 ESTABLISH conditions required to isolate leak.
3.4 IF RHR System must be isolated,THEN GO TO one of the following procedures, as applicable:
Ë S2.OP-AB.RHR-0001(Q), Loss of RHR
Ë S2.OP-AB.RHR-0002(Q), Loss of RHR At Reduced Inventory
3.5 REFER to Technical Specifications 3.4.1.3, 3.4.1.4, 3.5.2, 3.5.3, 3.9.8.1, and 3.9.8.2.
Page 1 of 1 C-26References: Dwg. 205326, 231035
S2.OP-AR.ZZ-0003(Q)
Salem 2 Page 32 of 57 Rev. 17
ALARM
C-2727
SFPLVLHI
DEVICES: 2LC650
SETPOINT: $ 129 feet 2 inches
1.0 CAUSE(S):
Pool level $ 129 feet 2 inches
2.0 AUTOMATIC ACTION:
None
3.0 OPERATOR ACTIONS:
3.1 IF alarm due to testing,THEN no further action required.
3.2 SEND Operator to confirm that a high level exists in the Spent Fuel Pool.
3.3 ENSURE CLOSED the following makeup valves:
A. 2SF44, PRIMARY WATER MAKEUP VALVE
B. 2SF58, DEMIN WATER MAKEUP
C. 2SF71, SPENT FUEL PIT FILL FROM HUT
3.4 IF alarm due to Cross-Connect Operations,THEN MONITOR level closely to prevent overfill of Spent Fuel Pool.
3.5 REDUCE level in Spent Fuel Pool to clear alarm IAW S2.OP-SO.SF-0001(Q),Fill and Transfer of the Spent Fuel Pool.
3.6 IF a failed instrument is indicated,THEN INITIATE a NOTF IAW LS-AA-120, Issue Identification and Screening Process
Page 1 of 1 C-27References: Dwg. 205333, 231100
S2.OP-AR.ZZ-0003(Q)
Salem 2 Page 33 of 57 Rev. 17
ALARM
C-2828
24 CFCUAIRFLO
TRBL
DEVICES: N/A
SETPOINT: N/A
1.0 CAUSE(S):
1.1 Roughing Filter Dampers not fully OPEN
1.2 HEPA Filter Inlet Damper not fully CLOSED
1.3 HEPA Filter Outlet Damper not fully CLOSED
2.0 AUTOMATIC ACTION:
None
3.0 OPERATOR ACTIONS:
3.1 IF 24 Containment Fan Coil Unit is operating in low speed,THEN no further Operator action is required.
3.2 VERIFY positions of 24 Containment Fan Coil Filter Dampers
on Control Console bezels.
3.3 IF damper malfunction is indicated,THEN:
A. STOP 24 Containment Fan Coil Unit.
B. INITIATE a NOTF IAW LS-AA-120, Issue Identification and Screening Process
3.4 REFER to Technical Specification 3.6.2.3.
Page 1 of 1 C-28References: Dwg. 205338, 203580
S2.OP-AR.ZZ-0003(Q)
Salem 2 Page 34 of 57 Rev. 17
ALARM
C-2929
24 CFCUWTRFLO
TRBL
DEVICES: N/A
SETPOINT: N/A
1.0 CAUSE(S):
Any SW Valve misalignment with the CFCU running:
‚ 24SW58, 24 FAN COIL UNIT INLET WATER VALVE not fully OPEN
‚ 24SW72, 24 FAN COIL UNIT OUTLET WATER VALVE not fully OPEN
‚ 24SW223, 24 FAN COIL UNIT OUTLET WATER FLOW CONTROL VALVE,is CLOSED
2.0 AUTOMATIC ACTION:
None
3.0 OPERATOR ACTIONS:
3.1 CONFIRM alarm by observing flow indication on 24 CFCU bezel.
3.2 OPEN the following valves:
A. 24SW58, 24 FAN COIL UNIT INLET WATER VALVE
B. 24SW72, 24 FAN COIL UNIT OUTLET WATER VALVE
3.3 IF a valve malfunction is suspected,THEN:
A. STOP 24 Containment Fan Coil Unit.
B. INITIATE a NOTF IAW LS-AA-120, Issue Identification and Screening Process
3.4 REFER to Technical Specification 3.6.2.3.
Page 1 of 1 C-29References: Dwg. 205342, 203582
S2.OP-AR.ZZ-0003(Q)
Salem 2 Page 35 of 57 Rev. 17
ALARM
C-3030
CFCULK DET
HI-HIM
DEVICES: 2LT730, 2LT731, 2LT732, 2LT733, 2LT734
SETPOINT: $ 15.2 feet of water
1.0 CAUSE(S):
Leak detector level $ 15.2 feet of water
2.0 AUTOMATIC ACTION:
None
3.0 OPERATOR ACTIONS:
3.1 DETERMINE which CFCU is causing the alarm from the Annunciator CRT:
CRT Point Description
497 CONTAINMENT FAN COIL UNIT 21LEAK DETECTOR HIGH-HIGH
498 CONTAINMENT FAN COIL UNIT 22LEAK DETECTOR HIGH-HIGH
499 CONTAINMENT FAN COIL UNIT 23LEAK DETECTOR HIGH-HIGH
500 CONTAINMENT FAN COIL UNIT 24LEAK DETECTOR HIGH-HIGH
501 CONTAINMENT FAN COIL UNIT 25LEAK DETECTOR HIGH-HIGH
(Continued)
Page 1 of 2 C-30
S2.OP-AR.ZZ-0003(Q)
Salem 2 Page 36 of 57 Rev. 17
3.2 ENSURE OPEN 21-25WD50, CFCU CONDENSATE SHUTOFF, at 2RP1.
3.3 IF there is indication of leakage other than Service Water,THEN INITIATE a leakrate IAW S2.OP-SO.RC-0004(Q),Identifying and Measuring Leakage.
3.4 IF there is indication of a Service Water leak,THEN:
A. STOP the affected CFCU.
CAUTION
Isolating a CFCU from the control room with the SW58 and SW72 valves also isolatesSW overpressure protection for the CFCU. These valves should only be used whenthere is a SW leak requiring immediate isolation.
B. ISOLATE the affected CFCU IAW S2.OP-SO.SW-0005(Q),Service Water System Operation.
C. INITIATE a NOTF IAW LS-AA-120, Issue Identification and Screening Process.
3.5 REFER to Technical Specification 3.6.1.1 and 3.6.2.3.
Page 2 of 2 C-30Reference Dwg. 205327, 220061, 240690
S2.OP-AR.ZZ-0003(Q)
Salem 2 Page 37 of 57 Rev. 17
ALARM
C-3131
DEVICES:
SETPOINT:
SPARE
Page 1 of 1 C-31References: Dwg.
S2.OP-AR.ZZ-0003(Q)
Salem 2 Page 38 of 57 Rev. 17
ALARM
C-3232
DEVICES:
SETPOINT:
SPARE
Page 1 of 1 C-32References: Dwg.
S2.OP-AR.ZZ-0003(Q)
Salem 2 Page 39 of 57 Rev. 17
ALARM
C-3333
RWST/PWSTOVRFLO
DEVICES: 1LD8040
SETPOINT: N/A
1.0 CAUSE(S):
1.1 Overflow from Unit 1 RWST or PWST
1.2 Overflow from Unit 2 RWST or PWST
2.0 AUTOMATIC ACTIONS:
None
3.0 OPERATOR ACTIONS:
3.1 DETERMINE which tank causing alarm.
A. STOP MAKEUP to affected tank.
B. SEND an operator to drain the dike area around 13 CVCS HUT as follows:.
1. Throttle OPEN 1WD7, 13 CVCS HUT DIKE DRAIN VALVE.
2. MONITOR Auxiliary Building Sump Tank level.
3. WHEN draining is completed,THEN CLOSE 1WD7, 13 CVCS HUT DIKE DRAIN VALVE.
3.2 WHEN dike is drained and affected tank level restored,THEN:
A. ESTABLISH communications with the control room.
B. Throttle OPEN 1WD54, RWST & PWST TO WHT DRN VALVE, to drain level detector 1LD8040 AND clear alarm.
Page 1 of 1 C-33References: Dwg. 205234
S2.OP-AR.ZZ-0003(Q)
Salem 2 Page 40 of 57 Rev. 17
ALARM
C-3434
22 RHRSUMP
OVRFLO
DEVICES: 2LD7755, 2LD7756
SETPOINT: $ 42 feet
1.0 CAUSE(S):
22 RHR Sump level $ 42 feet
2.0 AUTOMATIC ACTION:
None
3.0 OPERATOR ACTIONS:
3.1 IF RHR Sump Pumps have not started,THEN VERIFY CLOSED breakers:
Ë 2CY2AX6A, #23 RHR Sump Pump
Ë 2BY2AX6A, #24 RHR Sump Pump
3.2 SEND Operator to RHR Pump room and 84 ft elevation to determine source of leak.
3.3 ESTABLISH conditions required to isolate leak.
3.4 IF RHR System must be isolated,THEN GO TO one of the following procedures, as applicable:
Ë S2.OP-AB.RHR-0001(Q), Loss of RHR
Ë S2.OP-AB.RHR-0002(Q), Loss of RHR At Reduced Inventory
3.5 REFER to Technical Specifications 3.4.1.3, 3.4.1.4, 3.5.2, 3.5.3, 3.9.8.1, and 3.9.8.2.
Page 1 of 1 C-34References: Dwg. 205326, 231036
S2.OP-AR.ZZ-0003(Q)
Salem 2 Page 41 of 57 Rev. 17
ALARM
C-3535
SFPLVLLO
DEVICES: 2LC650
SETPOINT: # 128 feet 2 inches
1.0 CAUSE(S):
Spent Fuel Pit level is # 128 feet 2 inches
2.0 AUTOMATIC ACTION:
None
3.0 OPERATOR ACTIONS:
3.1 IF alarm is due to testing,THEN no further Operator action is required.
3.2 IF in Modes 1-5,THEN:
A. CONFIRM the alarm.
B. DETERMINE source of the leak.
C. INITIATE makeup to Spent Fuel Pit IAW S2.OP-SO.SF-0001(Q), Fill and Transfer of the Spent Fuel Pool.
3.3 IF in Mode 6,THEN:
A. SEND Operator to confirm the alarm.
B. IF Spent Fuel Pool level is decreasing,THEN GO TO S2.OP-AB.FUEL-0002(Q),Loss of Refueling Cavity or Spent Fuel Pool Level.
Page 1 of 1 C-35References: Dwg. 205333, 231100
S2.OP-AR.ZZ-0003(Q)
Salem 2 Page 42 of 57 Rev. 17
ALARM
C-3636
25 CFCUAIRFLO
TRBL
DEVICES: N/A
SETPOINT: N/A
1.0 CAUSE(S):
1.1 Roughing Filter Dampers not fully OPEN
1.2 HEPA Filter Inlet Damper not fully CLOSED
1.3 HEPA Filter Outlet Damper not fully CLOSED
2.0 AUTOMATIC ACTION:
None
3.0 OPERATOR ACTIONS:
3.1 IF 25 Containment Fan Coil Unit is operating in low speed,THEN no further Operator action is required.
3.2 ENSURE positions of 25 Containment Fan Coil Filter Dampers
on Control Console bezels.
3.3 IF damper malfunction is indicated,THEN:
A. STOP 25 Containment Fan Coil Unit.
B. INITIATE a NOTF IAW LS-AA-120, Issue Identification and Screening Process
3.4 REFER to Technical Specification 3.6.2.3.
Page 1 of 1 C-36References: Dwg. 205338, 203584
S2.OP-AR.ZZ-0003(Q)
Salem 2 Page 43 of 57 Rev. 17
ALARM
C-3737
25 CFCUWTRFLO
TRBL
DEVICES: N/A
SETPOINT: N/A
1.0 CAUSE(S):
Any SW Valve misaligned with the CFCU running:
‚ 25SW58, 25 FAN COIL UNIT INLET WATER VALVE not fully OPEN
‚ 25SW72, 25 FAN COIL UNIT OUTLET WATER VALVE not fully OPEN
‚ 25SW223, 25 FAN COIL UNIT OUTLET WATER FLOW CONTROL VALVE,is CLOSED
2.0 AUTOMATIC ACTION:
None
3.0 OPERATOR ACTIONS:
3.1 CONFIRM alarm by observing flow indication on 25 CFCU bezel.
3.2 ENSURE OPEN the following valves:
A. 25SW58, 25 FAN COIL UNIT INLET WATER VALVE
B. 25SW72, 25 FAN COIL UNIT OUTLET WATER VALVE
3.3 IF a valve malfunction is suspected,THEN:
A. STOP 25 Containment Fan Coil Unit.
B. INITIATE a NOTF IAW LS-AA-120, Issue Identification and Screening Process
3.4 REFER to Technical Specification 3.6.2.3.
Page 1 of 1 C-37References: Dwg. 205342, 203586
S2.OP-AR.ZZ-0003(Q)
Salem 2 Page 44 of 57 Rev. 17
ALARM
C-3838
CFCULK DET
HIM
DEVICES: 2LT730, 2LT731, 2LT732, 2LT733, 2LT734
SETPOINT: $ 0.8 feet of water
1.0 CAUSE(S):
Any Containment Fan Coil Unit leak detector level $ 0.8 feet of water
2.0 AUTOMATIC ACTION:
None
3.0 OPERATOR ACTIONS:
3.1 DETERMINE which CFCU is causing the alarm from the Annunciator CRT:
CRT Point Description
492 CONTAINMENT FAN COIL UNIT 21 LEAK DETECTOR HIGH
493 CONTAINMENT FAN COIL UNIT 22 LEAK DETECTOR HIGH
494 CONTAINMENT FAN COIL UNIT 23 LEAK DETECTOR HIGH
495 CONTAINMENT FAN COIL UNIT 24 LEAK DETECTOR HIGH
496 CONTAINMENT FAN COIL UNIT 25 LEAK DETECTOR HIGH
(Continued)
Page 1 of 2 C-38
S2.OP-AR.ZZ-0003(Q)
Salem 2 Page 45 of 57 Rev. 17
3.2 ENSURE OPEN 21-25WD50, CFCU CONDENSATE SHUTOFF, at 2RP1.
3.3 IF the alarm is due to suspected clogging of the drain line,THEN:
A. SELECT the CFCU for LEAK DETECTION indication (LI730) at 2CC1.
B. CLOSE the associated WD50 valve at 2RP1.
C. WAIT until the LEAK DETECTION indication (LI730) at 2CC1 is at a maximum value to facilitate flushing any sediment from the drain line.
D. OPEN the associated WD50 valve at 2RP1.
E. IF the alarm condition does NOT clear,THEN INITIATE an NOTF IAW LS-AA-120, Issue Identification and Screening Process.
3.4 IF there is indication of leakage other than Service Water,THEN INITIATE leakrate IAW S2.OP-SO.RC-0004(Q),Identifying and Measuring Leakage.
3.5 IF there is indication of Service Water leakage,THEN:
A. STOP the affected CFCU.
CAUTION Isolating a CFCU from the control room with the SW58 and SW72 valves also isolatesSW overpressure protection for the CFCU. These valves should only be used whenthere is a SW leak requiring immediate isolation.
B. ISOLATE the affected CFCU IAW S2.OP-SO.SW-0005(Q),Service Water System Operation.
C. INITIATE a NOTF IAW LS-AA-120, Issue Identification
and Screening Process.
D. INITIATE SC.OP-DG.SW-0005, Service Water Spill Response in Containment. *
3.6 REFER to Technical Specification 3.6.1.1 and 3.6.2.3.
Page 2 of 2 C-38References Dwg. 205327, 220061, 240690
S2.OP-AR.ZZ-0003(Q)
Salem 2 Page 46 of 57 Rev. 17
ALARM
C-3939
DEVICES:
SETPOINT:
SPARE
Page 1 of 1 C-39References: Dwg.
S2.OP-AR.ZZ-0003(Q)
Salem 2 Page 47 of 57 Rev. 17
ALARM
C-4040
DEVICES:
SETPOINT:
SPARE
Page 1 of 1 C-40References: Dwg.
S2.OP-AR.ZZ-0003(Q)
Salem 2 Page 48 of 57 Rev. 17
ALARM
C-4141
DEVICES:
SETPOINT:
SPARE
Page 1 of 1 C-41References:
S2.OP-AR.ZZ-0003(Q)
Salem 2 Page 49 of 57 Rev. 17
ALARM
C-4242
DEVICES:
SETPOINT:
SPARE
Page 1 of 1 C-42References: Dwg.
S2.OP-AR.ZZ-0003(Q)
Salem 2 Page 50 of 57 Rev. 17
ALARM
C-4343
DEVICES:
SETPOINT:
SPARE
Page 1 of 1 C-43References: Dwg.
S2.OP-AR.ZZ-0003(Q)
Salem 2 Page 51 of 57 Rev. 17
ALARM
C-4444
DEVICES:
SETPOINT:
SPARE
Page 1 of 1 C-44References: Dwg.
S2.OP-AR.ZZ-0003(Q)
Salem 2 Page 52 of 57 Rev. 17
ALARM
C-4545
DEVICES:
SETPOINT:
SPARE
Page 1 of 1 C-45References: Dwg.
S2.OP-AR.ZZ-0003(Q)
Salem 2 Page 53 of 57 Rev. 17
ALARM
C-46
46
PERSONNELACCESS
DOOR OPEN
DEVICES: N/A
SETPOINT: N/A
1.0 CAUSE(S):
Any personnel airlock in use to or from Containment at the locations listed:
‚ Elevation 100
‚ Elevation 130
2.0 AUTOMATIC ACTION:
None
3.0 OPERATOR ACTIONS:
3.1 IF an authorized Containment entry is being made,THEN:
A. RECORD Containment Airlocks and Loose Debris Inspection informationIAW S2.OP-DL.ZZ-0001(Q), Control Room Logs.
B. No further action required.
3.2 SEND Operator to ENSURE CLOSED airlock door(s).
3.3 IF unable to clear alarm,THEN:
A. REFER to Technical Specification 3.6.1.3.
B. INITIATE a NOTF IAW LS-AA-120, Issue Identification and Screening Process
C. PERFORM S2.OP-ST.CAN-0004(Q),Containment Air Lock Local Leak Rate Test.
Page 1 of 1 C-46References: Dwg. 231096
S2.OP-AR.ZZ-0003(Q)
Salem 2 Page 54 of 57 Rev. 17
ALARM
C-4747
DEVICES:
SETPOINT:
SPARE
Page 1 of 1 C-47References: Dwg.
S2.OP-AR.ZZ-0003(Q)
Salem 2 Page 55 of 57 Rev. 17
ALARM
C-4848
DEVICES:
SETPOINT:
SPARE
Page 1 of 1 C-48References: Dwg.
S2.OP-AR.ZZ-0003(Q)
Salem 2 Page 56 of 57 Rev. 17
OVERHEAD ANNUNCIATORS WINDOW C
REFERENCES
1.0 Plant Documents:
‚ Technical Specifications Unit 2‚ Event Classification Guide
2.0 Commitments:
C0551, LER 272/94-013-00
3.0 Procedures:
None
4.0 PSBPs:
None
5.0 Other:
‚ 2EC-3228, Provide reflash capability to C-1 window‚ ECA 80004565, OHA C-24 CBV ISOL SIGNAL PRESENT spared‚ INPO SER 40-86, Spent Fuel Pool Leakage‚ 2EC-1707A, Reset setpoint of LS-2067‚ MM S97-0095, Hydrogen Recombiner HI-KW Alarm Relay Removal‚ S-C-SF-MDC-1800, Decay Heatup Rates and Curves
6.0 Cross-References:
‚ 2-EOP-TRIP-1, Reactor Trip or Safety Injection‚ S2.OP-AB.CC-0001(Q), Component Cooling Abnormality‚ S2.OP-AB.FUEL-0002(Q), Loss of Refueling Cavity or Spent Fuel Pool Level‚ S2.OP-AB.RC-0001(Q), Reactor Coolant System Leak.‚ S2.OP-AB.RCP-0001(Q), RCP Abnormality‚ S2.OP-AB.RHR-0001(Q), Loss of RHR‚ S2.OP-AB.RHR-0002(Q), Loss of RHR At Reduced Inventory‚ S2.OP-AB.SF-0001(Q), Loss of Spent Fuel Pool Cooling‚ S2.OP-AB.SW-0001(Q), Loss of Service Water Header Pressure‚ S2.OP-AR.WG-0001(Q), Waste Disposal Gas Analyzer PNL 110‚ S2.OP-SO.RC-0004(Q), Identifying and Measuring Leakage‚ S2.OP-SO.RPS-0005(Q), Placing Containment Pressure Channel In Tripped Condition‚ S2.OP-SO.SF-0001(Q), Filling the Spent Fuel Pool‚ S2.OP-ST.CAN-0004(Q), Containment Air Lock Local Leak Rate Test
S2.OP-AR.ZZ-0003(Q)
Salem 2 Page 57 of 57 Rev. 17
7.0 Drawings:
‚ 203568, No. 1 & 2 Units-Containment Ventilation No.11 & 21 Fan-Coil Units‚ 203570, No. 1 & 2 Units-Containment Ventilation No.11 & 21 Fan-Coil Units‚ 203572, No. 1 & 2 Units-Containment Ventilation No.12 & 22 Fan-Coil Units‚ 203574, No. 1 & 2 Units-Containment Ventilation No.12 & 22 Fan-Coil Units‚ 203576, No. 1 & 2 Units-Containment Ventilation No.13 & 23 Fan-Coil Units‚ 203578, No. 1 & 2 Units-Containment Ventilation No.13 & 23 Fan-Coil Units‚ 203580, No. 1 & 2 Units-Containment Ventilation No.14 & 24 Fan-Coil Units‚ 203582, No. 1 & 2 Units-Containment Ventilation No.14 & 24 Fan-Coil Units‚ 203584, No. 1 & 2 Units-Containment Ventilation No.15 & 25 Fan-Coil Units‚ 203586, No. 1 & 2 Units-Containment Ventilation No.15 & 25 Fan-Coil Units‚ 203653, No. 1 & 2 Units-Containment Ventilation No.11 & 21 Hydrogen Recombiners‚ 203654, No. 1 & 2 Units-Containment Ventilation No.12 & 22 Hydrogen Recombiners‚ 203683, No. 1 & 2 Units-Waste Disposal System Gas Analyzer Panel 110‚ 205234, No. 1 Unit Safety Injection‚ 205326, No. 2 Unit Floor Drains Contaminated‚ 205327, No. 2 Unit Equipment Vents & Drains-Contaminated‚ 205329, No. 2 Unit-Chemical & Volume Control Boric Acid Recovery‚ 205331, No. 2 Unit Component Cooling‚ 205333, No. 2 Unit Spent Fuel Cooling‚ 205338, No. 2 Unit Reactor Containment-Ventilation‚ 205342, No. 2 Unit Service Water Nuclear Header‚ 211514, No. 1 & 2 Units-RHR Sys. Containment Sump Level LT-939‚ 211522, No. 1 & 2 Units-CC System Surge Tank, No.11&21 CC Hdr Press Alarms‚ 211523, No. 1 & 2 Units-CC System Surge Tank, No.12&22 CC Hdr Press Alarms‚ 217142, No. 1 & 2 Units-Safety Injection System Spray Additive Tk & RWST Level Alarms‚ 220061, No. 1 & 2 Units Reactor Prot. & Process Cont. Systems Leak Detection‚ 220972, No. 1 & 2 Units-Reactor Containment Reactor & Containment Sump Pumps‚ 221057, No. 1 & 2 Units Reactor Protection System Safeguards Actuation Signals‚ 222875, No. 1 & 2 Units-CVCS Gas Stripper & Boron Control Panel No.301‚ 226513, No. 1 & 2 Units-Aux. Building 64 Waste Disposal-Boron Recycle Panel 104‚ 227977, No. 1 & 2 Units-Control Room Area SSPS System Train A Interface Cab.32‚ 231035, No. 1 & 2 Units-Auxiliary Building RHR No.11 & 12 Sump Pumps‚ 231036, No. 1 & 2 Units-Auxiliary Building RHR No.13 & 14 Sump Pumps‚ 231096, No. 1 & 2 Units- Cont Area Personnel Access Hatch indication & Alarms‚ 231100, No. 1 & 2 Units-Spent Fuel Pit Cooling Spent Fuel Pit Level & Temperature‚ 232015, No. 1 & 2 Units-Control Room Area SSPS System Train A Output Test‚ 232016, No. 1 & 2 Units-Control Room Area SSPS Train A Output Test‚ 240690, No. 2 Unit Equipment Vents & Drains Contaminated‚ 240698, No. 2 Unit Sump and Flood Pumps-Contaminated‚ 252310, No. 1 & 2 Units-Containment Ventilation Hydrogen Monitoring System