3D Systems, Inc.

ProX® SLS 61003D PrinterFacility Guide Original Instructions

Page 2: ProX® SLS 6100 - 3D Systemsinfocenter.3dsystems.com/product-library/sites/default/... · 2019. 3. 1. · process station must be flat and vibration-free. The room must be air-conditioned,

3D Systems, Inc. i p/n 76-D022 Rev. B

CONTENTS

1 HOW TO PREPARE FOR INSTALLATION . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1Safety Precautions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1

2 UNCRATING THE MACHINE . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2

3 WHAT YOUR SYSTEM INCLUDES . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5Required System Components . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5

ProX® SLS 6100 3D Printer . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .6

SLS Single MQC System . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .7

Part Transfer Cart . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .9

Vacuum Cleaner . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .10

Dust Extractor . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .10

ProX® SLS 6100 Transformer . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .10

4 RECOMMENDED OPIONAL EQUIPEMENT . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 11Recommended Optional Equipment . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 11Room Area Oxygen Monitor . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 11Bead Blaster . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 11

5 CONSUMABLES . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 12Nitrogen Consumption . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 12SLS Materials . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 12Replaceable Filters Kit . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 12

6 FACILITY REQUIREMENTS CHECKLIST . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 13About the Checklist . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 13How to Submit Your Completed Facilities Checklist . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 13

Facility Requirements Checklist - ProX® SLS 6100 3D Printer and Auxiliary Equipment . . . . . . . . . . . . . . . . . . . . . . . . . . .14

7 ROOM REQUIREMENTS . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 15Clearance Requirements – ProX® SLS 6100 Station . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 15Clearance Requirements – SLS Single MQC System . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 15Floor Requirements . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 15

8 OPERATING REQUIREMENTS . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 16

9 ELECTRICAL REQUIREMENTS . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 17ProX® SLS 6100 Process Station Power Requirements . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 17ProX® SLS 6100 Transformer Requirements . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 17SLS SINGLE MQC System Power Requirements . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 18Grounding Requirements . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 18

10 NITROGEN AND COMPRESSED AIR REQUIREMENTS . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 19Nitrogen Supply Requirements . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 19Nitrogen Supply Options . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 19

N2 Generator O2 Exhaust . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .19

Nitrogen Supply and Exhaust Lines . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 19Compressed Air Requirements . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 19

Page 3: ProX® SLS 6100 - 3D Systemsinfocenter.3dsystems.com/product-library/sites/default/... · 2019. 3. 1. · process station must be flat and vibration-free. The room must be air-conditioned,

3D Systems, Inc. ii p/n 76-D022 Rev. B

11 NETWORK REQUIREMENTS . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 20

12 3D CONNECT REQUIREMENTS . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 21

13 SHIPPING WEIGHTS AND DIMENSIONS . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 22System Component Weights and Dimensions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 22

14 PROX® SLS 6100 SHIP KIT . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 23

15 SINGLE MQC SHIP KIT . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 24

16 ProX SLS 6100 3D PRINTER FACILITY REQUIREMENTS POSTER . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 25

Page 4: ProX® SLS 6100 - 3D Systemsinfocenter.3dsystems.com/product-library/sites/default/... · 2019. 3. 1. · process station must be flat and vibration-free. The room must be air-conditioned,

3D Systems, Inc. 1 p/n 76-D022 Rev. B

Use this guide to help you prepare your facility for installation of the:

• ProX® SLS 6100 3D Printer

• SLS Single MQC System

• Auxiliary equipment for finishing parts created with the ProX® SLS 6100

This guide gives you the information and guidance you need to complete the Facility Requirements Checklist - ProX® SLS 6100 3D Printer and Auxiliary Equipment . You must complete this checklist and send it to 3D Systems when you’re ready to have your equipment installed .

At the back of this guide, you will find the ProX® SLS 6100 Facility Poster which gives you a layout view of the facility requirements for the ProX® SLS 6100 3D Printer, SLS Single MQC System, and auxiliary equipment .

SAFETY PRECAUTIONSPlease review all safety information in the Safety Guidelines and Instructions section of the ProX SLS 6100 User Guide.The conditions in which the printer is crated, stored, transported, and un-crated, are covered in this Facility Guide, available to the user . This guide contains a described sequence for crating, re-crating, and transport . Details on lifting, moving, and storage are also provided .

CAUTION: After you receive your equipment, do not allow anyone to connect electrical power, compressed air, or nitrogen to any of these devices. This must only be done by your 3D Systems-certified Customer Support Engineer (3D CSE) during installation.

Attempts to install equipment or auxiliary equipment by non-3D Systems-certified personnel could void the warranty and result in serious injury and equipment damage.

The weight and size of the machine (Section 12: Shipping Weights and Dimensions) should be considered at all times: during use, transportation, assembly, dismantling when out of service, testing or foreseeable breakdowns . By following the safety and facility requirements detailed in this guide, the stability of the printer does not require additional definition(s) outside the contents of this guide.

1 HOW TO PREPARE FOR INSTALLATION

Page 5: ProX® SLS 6100 - 3D Systemsinfocenter.3dsystems.com/product-library/sites/default/... · 2019. 3. 1. · process station must be flat and vibration-free. The room must be air-conditioned,

3D Systems, Inc. 2 p/n 76-D022 Rev. B

2 UNCRATING THE MACHINE

INSPECT EXTERIOR OF CRATEVisually inspect the exterior of the crate for any damage that may have occurred during shipping. Notify shipping carrier immediately to file a claim if any damage is evident at this point. DO NOT proceed with the uncrating until you have discussed the damage with 3D Systems.

NOTE: Uncrating the ProX® SLS 6100 will require at least two people to safely remove the each panel .

1 . Located on the side of the crate is the “clip removeal tool” . It is secured under a clip . To release the tool, grab the handle and pull it towards you to pop out the first clip.

NOTE: To keep clips from popping off too quickly you may want to hold your hand over the top of the clip .

2 . Using at least a 5 foot sized ladder, remove the (12) clips from the side of the crate as shown . Remove and place panel to the side .

3 . Remove the remaining (8) clips that secure the top panel . Carefully slide/guide the top crate panel towards the other side of the crate until it reaches a tipping point . Tip and lower the panel to the ground . Set panel to the side .

4 . Remove the (6) clips (circled in red) from one side of the crate panel . Remove panel and place to the side . Repeat step on opposite side .

5 . Remove the final side panel by removing the bottom (2) clips (circled in blue) . Place panel to the side .

Page 6: ProX® SLS 6100 - 3D Systemsinfocenter.3dsystems.com/product-library/sites/default/... · 2019. 3. 1. · process station must be flat and vibration-free. The room must be air-conditioned,

3D Systems, Inc. 3 p/n 76-D022 Rev. B

6 . Using a 9/16” socket and wrench, remove the (4) screws from brackets from each corner of the printer .

7 . Save the (4) screws and brackets for future crating use .

8 . Using a forklift capable of lifting 3000 pounds, spread the forks from the forklift so they span the width of the open-ing as shown .

9 . Carefully guide the forks under the printer while using caution not to damage the front of the printer .

Page 7: ProX® SLS 6100 - 3D Systemsinfocenter.3dsystems.com/product-library/sites/default/... · 2019. 3. 1. · process station must be flat and vibration-free. The room must be air-conditioned,

3D Systems, Inc. 4 p/n 76-D022 Rev. B

10 . Slowly lift the printer several inches until it is cleared from the pallet .

11 . Slide the pallet away from under the printer as shown .

12 . Slowly lower the printer to the floor.

13 . Roll the printer to the desired destination .

NOTE: If recrating the printer, please use the instructions in reverse order .

14 . Once the printer has been rolled into the desired location, secure the printer using the (4) casters by raising the cast-ers onto the leveling feet . At this point the printer is stable for operation, testing and service .

Page 8: ProX® SLS 6100 - 3D Systemsinfocenter.3dsystems.com/product-library/sites/default/... · 2019. 3. 1. · process station must be flat and vibration-free. The room must be air-conditioned,

3D Systems, Inc. 5 p/n 76-D022 Rev. B

This section lists all required and optional components for the ProX® SLS 6100 3D Printer System . These include:

• ProX® SLS 6100 3D Printer

• SLS Single MQC System

• Auxiliary equipment for finishing parts created with the ProX® SLS 6100

• Maintenance and safety equipment for cleaning the system and protecting operators and service personnel

• Items consumed during part printing “consumables” such as powder, nitrogen, and filters

NOTE: The ProX® SLS 6100 3D Printer prints many types of parts out of several types of SLS materials . Each application has some unique requirements . Your system will most likely not include every component and material listed in this section . Just focus on the components and materials included in your order .

It is especially important that you prepare your facility for all non-3D Systems-supplied components in your order . These are indicated in each section . The facilities for these non-3D Systems-supplied components—and in some cases the components themselves—must be in place before the ProX® SLS 6100, SLS Single MQC System, and any auxiliary equipment from 3D Systems can be installed .

REQUIRED SYSTEM COMPONENTSYour ProX® SLS 6100 must include the components described below . Most of these components are 3D Systems supplied and installed; others can be one of the following:

• Customer-supplied and supplier-installed

• Customer-supplied and 3D Systems installed

NOTE: Contact 3D Systems Customer Support if you need help reaching a supplier .

When a required system component can be customer-supplied, the source (or sources) for the component are listed, along with purchasing information .

All required system components are listed below . Each component is detailed separately in the sections that follow .

• ProX® SLS 6100 3D Printer• SLS Single/Double MQC System• Nitrogen Generator or a comparable Nitrogen source• Vacuum Cleaner• Dust Extractor• ProX® SLS 6100 Transformer

3 WHAT YOUR SYSTEM INCLUDES

Page 9: ProX® SLS 6100 - 3D Systemsinfocenter.3dsystems.com/product-library/sites/default/... · 2019. 3. 1. · process station must be flat and vibration-free. The room must be air-conditioned,

3D Systems, Inc. 6 p/n 76-D022 Rev. B

ProX® SLS 6100 3D PrinterSupplied by: 3D Systems

Installed by: 3D Systems

The printer requires a 3-phase, 208 VAC, 50/60 Hz, 10 kVA power source .

Ceiling drop lines for nitrogen supply and exhaust, electrical, and clean dry air (CDA) are recommended. The floor below the process station must be flat and vibration-free. The room must be air-conditioned, with no vents directly above the machine. Clearance around the process station is required so hinged access panels can be fully opened . See the ProX® SLS 6100 3D Printer Facility Requirements Poster in section 14 of this Facility Guide for clearance requirements .

FB

A

D

E

C

Stacklight: Indicates the state of the system .

Print Chamber Area: There are two doors in front of the Print Chamber—the outer locking door, and the inner print chamber door . The parts are printed inside the Print Chamber .

E-Stop: The Emergency Stop button is a safety mechanism used to shut off the machine in an emergency situation in which it cannot be shut down in the usual manner .

User Interface (UI): The user controls the system using a monitor located on the front panel .

LED Interface Lights and Controls: There are three LED’s which give the user visual feedback regarding the system . The two buttons allow the user to control the chamber lights and enable the system . There is (1) standard USB ports beneath the LED’s .

User and Service Access Panels: There are two types of panels on the sides and back of the machine—user access and service access . The user access panels are hinged doors . The service access panels are lift-off panels . A tool is required to open each service panel .

A

B

C

D

E

F

Page 10: ProX® SLS 6100 - 3D Systemsinfocenter.3dsystems.com/product-library/sites/default/... · 2019. 3. 1. · process station must be flat and vibration-free. The room must be air-conditioned,

3D Systems, Inc. 7 p/n 76-D022 Rev. B

SLS Single MQC SystemSupplied by: 3D Systems

Installed by: 3D Systems

The SLS Single MQC System is an integral part of the ProX® SLS 6100 3D Printer . It is responsible for properly regulating and controlling the SLS material used to print parts with the ProX® SLS 6100 3D Printer, as well as breaking out parts from the print cake .

Breakout Controls: This roller switch allows the user to turn the sifter ON or OFF .

Blended Material Bin: Material which is a combination of used material and fresh material is stored for production use

in this hopper . The system handles this automatically .

Fresh Material Input: Fresh material is loaded at this location . The user must scan the RFID tag on the container

across the RFID reader .

RFID Reader: The RFID reader is used to scan the RFID tag of the material container . This ensures that the system

keeps track of material quantity and fresh-to-new powder ratios . The tag must be scanned to unlock the Fresh Material

input doors and add the material to the system .

Breakout Area: The print cake is brought here using the Print Transfer Cart Assembly .

Reject Chute: Spent material (as determined by the user) is loaded into the reject chute .

Thermocouples: Two temperature gauges for the print cake are used to determine whether or not the print cake has

cooled sufficiently before breaking out the parts.

Nitrogen Blanket: This lid is placed on top of a filled print cake cylinder to control the cooldown of the print cake using

nitrogen .

Stowaway Area: Underneath the breakout area, there is a space which can be used to store part extraction cylinders

when they are not in use .

Sifter: The user removes the parts from the print cake in the breakout area and places the material for reuse into the

sifter . After sifting, the material will be transported to the blended material bin .

SLS Single MQC System Operator Controls: User interface for operation of the SLS Single MQC System .

A

I

A

K

G

H

SLS Single MQC System – Front View

B

C D EF

J

B

C

D

E

F

G

H

I

J

K

Page 11: ProX® SLS 6100 - 3D Systemsinfocenter.3dsystems.com/product-library/sites/default/... · 2019. 3. 1. · process station must be flat and vibration-free. The room must be air-conditioned,

3D Systems, Inc. 8 p/n 76-D022 Rev. B

Ethernet Adaptor: Network connections to service 1 printer and a laptop (for service personnel only) .

USB Adapter

4-Pin Connector for Oxygen Sensor

Nitrogen Inlet: Input for nitrogen supply .

Quick-Disconnect Air Fitting: Input for compressed air coming into the MQC System .

Pressure Regulator (Nitrogen)

Pressure Regulator (Air)

Pressure Regulator (Air)

Transport Filter: The material filter for the SLS Single MQC Use System.

A

B

C

D

E

F

G

H

I

I

E

A

B

C

D

F

G

H

SLS Single MQC System – Rear View

Page 12: ProX® SLS 6100 - 3D Systemsinfocenter.3dsystems.com/product-library/sites/default/... · 2019. 3. 1. · process station must be flat and vibration-free. The room must be air-conditioned,

3D Systems, Inc. 9 p/n 76-D022 Rev. B

Nitrogen GeneratorSupplied by: 3D Systems

Installed by: 3D Systems

See Nitrogen Requirements in Section 10 in this Facility Guide for nitrogen supply equipment specifications.

Part Transfer TrayExtraction Cylinder

Part Transfer CartSupplied by: 3D Systems

Installed by: 3D Systems

The print cake Extraction Cylinder, Part Transfer Tray and Part Transfer Cart are used to remove the print cake from the ProX® SLS 6100 print chamber and transport it to the SLS Single MQC System . The system ships with the cylinder and tray . The transfer cart is optional .

Part Transfer Cart

3D Systems

NitrogenGenerator

Compressed Air Inlet

O2 exhaustN2 outletN2 exit

Page 13: ProX® SLS 6100 - 3D Systemsinfocenter.3dsystems.com/product-library/sites/default/... · 2019. 3. 1. · process station must be flat and vibration-free. The room must be air-conditioned,

3D Systems, Inc. 10 p/n 76-D022 Rev. B

ProX® SLS 6100 TransformerSupplied by: 3D Systems or customer

Installed by: Supplier (prior to ProX® SLS 6100 3D Printer installation)

A customer-supplied step-up or step-down transformer is required if the facility does not have 208 VAC, 3-phase, 50/60 Hz, 10 kVA power .

There are two U .S . models and one E .U . model available for purchase from 3D Systems:US Transformers:

• 230-250 Volt to 208VAC, 10kVA, 60Hz, 3PH

• 460-500 Volt to 208VAC, 10kVA, 60Hz, 3PH

EU Transformer• 385-415 Volt to 208VAC, 10kVA, 50Hz, 3PH

Dust ExtractorSupplied by: 3D Systems or customer

Installed by: Supplier (3D Systems or customer)

The Dust Extractor, 230VAC, 60Hz, 3PH and 400VAC, 50Hz, 3PH draws airborne powder out of the MQC System during part breakout through a flexible vacuum duct and collects airborne powder in the internal dust drawer for disposal . It is recommended that the Dust Extractor be situated at the rear-right of the SLS Single MQC System, but it is possi-ble to locate it as much as 50 meters away .

Vacuum CleanerSupplied by: 3D Systems or customer

Installed by: Supplier (3D Systems or customer)

The Nilfisk S2 Industrial Single Phase Vacuum Cleaner, 120V, 60Hz, 1Ph, is recommended for SLS facility maintenance . It is used to clean the process station and MQC System between prints .

Explosion-proof and international versions are also available . Contact 3D Customer Service for purchasing options .

Page 14: ProX® SLS 6100 - 3D Systemsinfocenter.3dsystems.com/product-library/sites/default/... · 2019. 3. 1. · process station must be flat and vibration-free. The room must be air-conditioned,

3D Systems, Inc. 11 p/n 76-D022 Rev. B

RECOMMENDED OPTIONAL EQUIPMENTYour ProX® SLS 6100 System can optionally include the components listed below . These are described in the sections that follow .

• Room Area Oxygen Monitor

• Bead Blaster

ROOM AREA OXYGEN MONITORSupplied by: 3D Systems

• Oxygen Room Monitor, 120V

• Oxygen Room Monitor, 220V, Universal Plugs

Installed by: 3D Systems

Source: 3D Systems

For safety when working with nitrogen, 3D Systems recommends you install a room area oxygen monitor on the wall of your ProX® SLS 6100 room .

Refer to the safety guidelines included in the ProX® SLS 6100 User Guide for information on safely working with nitrogen and oxygen .

BEAD BLASTERSupplied by: 3D Systems

Installed by: 3D Systems

If you plan to use DuraForm® SLS material, 3D Systems recommends you install a pneumatic abrasive blast cabinet (bead blaster) in the part finishing area separate from the ProX SLS 6100 3D Printer process station room .

The Bead Blaster Station is a glass bead blaster which is very useful for cleaning sintered DuraForm parts . It requires a 5 .5 bar (80 psi) compressed air line and a 110 VAC/60 Hz power source (U .S . and Asia Pacific version) or a 240 VAC/50 Hz power source (European version).

Caution: A anti-static mat is recommended during post-processing to reduce the risk of shock .

4 RECOMMENDED OPIONAL EQUIPEMENT

Page 15: ProX® SLS 6100 - 3D Systemsinfocenter.3dsystems.com/product-library/sites/default/... · 2019. 3. 1. · process station must be flat and vibration-free. The room must be air-conditioned,

3D Systems, Inc. 12 p/n 76-D022 Rev. B

The following items are consumed at varying rates during the SLS process:

• Nitrogen

• SLS Materials

• Filters

These items are described separately in the sections that follow .

• Contact 3D Systems to purchase replacement SLS materials and filters.

• See your nitrogen supplier to replenish stocks of this item.

NITROGEN CONSUMPTION

NOTE: Your site’s actual nitrogen consumption may vary from the nitrogen consumption estimate below .

One ProX® SLS 6100 3D Printer system will consume approximately 140 cubic meters (4944 cubic feet) of nitrogen gas per week . This estimate assumes seven days of continuous operation (24 hours/day) with seven purge cycles (one per day) .

NOTE: This volume estimate is for gaseous nitrogen—not liquid nitrogen . Be sure to ask your supplier for the proper liquid-to-gas volume conversion ratio so you can properly size your tanks .

SLS MATERIALSThe material listed below is available for purchase from 3D Systems . The material comes with its own 3D Systems Material Guide to help you use it successfully .

• DuraForm® ProX PA

• DuraForm® ProX AF+

• DuraForm® ProX FR1200

• DuraForm® ProX GF

• DuraForm® ProX HST

• DuraForm® ProX EX Black

Refer to your Material Guide for further information .

REPLACEABLE FILTERS KITThe process station and chiller have customer-replaceable filters. 3D Systems recommends you keep a supply of these filters on hand and replace them when necessary to ensure part quality and trouble-free operation . 3D Systems sells a kit containing a year’s supply of filters.

FILTER KIT (P/N 132562-00)

Laser Power Supply Filter

EPM Filter, Pleated

EPM filter, Charcoal, Pleated

Seal, HEPA Filter

Filter, HEPA

Filter, 2-stage, 5u (Sock)

Electrical cabinet filters

CDA Filter on pressure regulator

NOTE: Filters are also replaced as necessary by your 3D Systems Field Service Representative during scheduled preventive maintenance visits .

5 CONSUMABLES

Page 16: ProX® SLS 6100 - 3D Systemsinfocenter.3dsystems.com/product-library/sites/default/... · 2019. 3. 1. · process station must be flat and vibration-free. The room must be air-conditioned,

3D Systems, Inc. 13 p/n 76-D022 Rev. B

In the sections that follow, you will find all of the requirements your facility must meet before your ProX® SLS 6100 3D Printing System can be installed . After your facility meets these requirements, please complete and sign the Facility Requirements Checklist and submit to 3D Systems Technical Support for review .

When Technical Support receives your completed checklist, a 3D Systems representative will contact you to verify your facility’s readiness. When the representative is confident that all facility requirements are met, he or she will schedule a trip to your site to install the ProX® SLS 6100 3D Printer and any additional SLS equipment which was ordered .

NOTE: All facility requirements must be met before 3D Systems Technical Support can schedule a trip to your facility to install the SLS equipment .

ABOUT THE CHECKLISTEach facility feature on the checklist is covered in the subsequent “requirements” sections of this guide . Each of these sections lists the specific requirements for a facility feature and any instructions you need to meet them. In some cases, you must refer to the ProX® SLS 6100 3D Printer Facility Requirements Poster, for example, when you lay out the room or wire electrical power . The instructions tell you when you need to refer to this drawing .

• After your facility meets all the requirements for a section, check off that section on the Facility Requirements Checklist.

• If you have any questions regarding facility requirements, contact your 3D Systems Sales representative or 3D Systems Technical Support.

HOW TO SUBMIT YOUR COMPLETED FACILITIES CHECKLISTSubmit your completed Facility Requirements Checklist by fax, mail, or email to one of the 3D Systems Technical Support sites below. This notifies them that your facility is fully prepared for installation.

COMMUNICATIONS FORMAT NORTH & SOUTH AMERICA; ASIA PACIFIC EUROPE

Fax +1 512-339-0634attn: SLS Customer Support

+49 6151 357 355attn: SLS Customer Support

Mail 3D Systems Corporation333 Three D Systems CircleRock Hill, SC 29730attn: SLS Customer Support

3D Systems GmbHRontgenstrasse 41D-64291 Darmstadt, Germanyattn: SLS Customer Support

Email support@3dsystems .com support@3dsystems .com

Be sure to include the date that you submitted your completed checklist so installation can be scheduled as quickly as possible .

If you need to speak to a 3D Systems Technical Support representative about your facility requirements, call:

• 1.888.598.1438 (U.S.)

• (+49) 6151.357-0 (Europe)

• (+852) 29.23.50.77 (Asia Pacific)

6 FACILITY REQUIREMENTS CHECKLIST

Page 17: ProX® SLS 6100 - 3D Systemsinfocenter.3dsystems.com/product-library/sites/default/... · 2019. 3. 1. · process station must be flat and vibration-free. The room must be air-conditioned,

3D Systems, Inc. 14 p/n 76-D022 Rev. B

IMPORTANTYou must complete and sign this form before scheduling installation. The information on this form will be used to

determine the necessary time that 3D Systems personnel will need to complete the installation.

Contact name

Phone, email, fax Phone Email Fax

Facility address

Date submitted

Room Requirements completed

Atmosphere Requirements completed

Electrical Requirements completedMeasured facility power: ________ VAC, ________ Hz

Nitrogen Requirements completed

Computer and Network Requirements completed

Signature

Facility Requirements Checklist - ProX® SLS 6100 3D Printer and Auxiliary Equipment

Page 18: ProX® SLS 6100 - 3D Systemsinfocenter.3dsystems.com/product-library/sites/default/... · 2019. 3. 1. · process station must be flat and vibration-free. The room must be air-conditioned,

3D Systems, Inc. 15 p/n 76-D022 Rev. B

Refer to the ProX® SLS 6100 3D Printer Facility Requirements Poster for a visual layout of the room requirements .

CLEARANCE REQUIREMENTS – ProX® SLS 6100 STATION

MINIMUM CLEARANCE WIDTH DEPTH HEIGHT

Room 427 cm (14 ft) 366 cm (12 ft) 305 cm (10 ft)

Access door1 191 cm (6 .25 ft) -- 244 cm (8 ft)

1 . The process station is 230 cm (7 .5 ft) tall and 175 cm (5 .75 ft) wide, but extra clearance is needed if it is on a pallet .

CLEARANCE REQUIREMENTS – SLS SINGLE MQC SYSTEM

MINIMUM CLEARANCE WIDTH DEPTH HEIGHT

Room 481 cm (16 ft) 427 cm (14 ft) 305 cm (10 ft)

Access door1 290 cm (9 .5 ft) -- 260 cm (8 .5 ft)

1 . The SLS Single MQC System is 244 cm (8 ft) tall and 275 cm (9 ft) wide, but extra clearance is needed if it is on a pallet .

FLOOR REQUIREMENTS

REQUIREMENTS COMMENTS

Vibration-free Required

First floor installation Preferred

Level and flatness within 25 .4 mm (1 in) below the printer

Distributed load-bearing capacity

• The weight of the ProX® SLS 6100 process station is 1361 kg (3000 lbs) . The weight of the station is distributed on four 68 mm (2 .7 in) diameter pads .

• This is an area of 3631 mm2 (5 .628 in2) per pad . The total area for all four pads is 1,427 mm2 (2 .212 in2)

• Each pad receives 903 kPa (131 psi, 0 .0937 kg/mm2)

7 ROOM REQUIREMENTS

Page 19: ProX® SLS 6100 - 3D Systemsinfocenter.3dsystems.com/product-library/sites/default/... · 2019. 3. 1. · process station must be flat and vibration-free. The room must be air-conditioned,

3D Systems, Inc. 16 p/n 76-D022 Rev. B

Locate the ProX® SLS 6100 3D Printer system in a convenient location meeting the requirements specified in this document. To ensure optimum performance, it is important that the printer be installed in a clean, dry, air-conditioned room . Avoid placing the printer in any environment with airborne contaminants, including cigarette smoke, fumes, and mechanical particulates that can adversely affect the long term performance of the equipment .

The atmosphere in the ProX SLS 6100 installation room must meet the following specifications:

ATMOSPHERIC VARIABLES REQUIREMENTS

Room temperature controls Heating and air conditioning installedA/C not blowing on top of process station

TemperatureOperating range: (16-32) °C; (60 to 90) °F

Stability: ± 2 °C (± 5 °F)

Non-condensing relative humidity No higher than 70%

Room air changes 4 per hour minimum

Heat dissipation Maximum: 5kW (17,000 BTU/hr)Average: 2 .4kW (13,000 BTU/hr)

Atmospheric corrosives None; Clean Dry Air (CDA) is required

ProX SLS Noise output

The A-weighted sound pressure levels measured at 1 meter from the surface of the machinery and at a height of 1 meter from the floor is as follows:

• Ambient 62 .9dB

• Front 68 .3dB

• Left 72 .0dB

• Right 72 .6dB

• Rear 70 .0dB

NOTE: ATEX-MQC must be installed in a room that meets the same or higher ATEX-level certification.

8 OPERATING REQUIREMENTS

Page 20: ProX® SLS 6100 - 3D Systemsinfocenter.3dsystems.com/product-library/sites/default/... · 2019. 3. 1. · process station must be flat and vibration-free. The room must be air-conditioned,

3D Systems, Inc. 17 p/n 76-D022 Rev. B

ProX® SLS 6100 TRANSFORMER REQUIREMENTSIf the facility does not have 208 VAC, 3-phase, 50/60 Hz, 10 kVA power, a customer-supplied step-up or step-down transformer is required .

3D Systems stocks the following transformers:

DESCRIPTION 3D SYSTEMS PART NO .

Transformer, 230-250 Volt to 208VAC, 10kVA, 60Hz, 3PH 134005

Transformer, 460-500 Volt to 208VAC, 10kVA, 60Hz, 3PH 134006

Transformer, 385-415 Volt to 208VAC, 10kVA, 50Hz, 3PH (EU Version) 75-0265

• If you purchase a transformer from a supplier other than 3D Systems, specify a “wye-to-delta” primary-to-secondary config-uration .

• Connect the transformer secondary neutral to the transformer secondary ground .

Caution: Do not connect the transformer secondary neutral to the printer ground.

Refer to the ProX® SLS 6100 3D Printer Facility Requirements Poster and SLS Single MQC System Facility Requirements Poster for visual layouts of the electrical connections .

NOTE: The ProX® SLS 6100 requires a three phase AC mains power . Incoming facility power should be brought into the machine through a fused disconnect switch enclosure . 3D Systems recommends a disconnect switch with a Class J, current-limiting, time-delay, 35A, 600 VAC rated fuse protecting each power phase with lockout/tagout capabilities . Consult your local electrician for additional requirements .

ProX® SLS 6100 PROCESS STATION POWER REQUIREMENTS

COMPONENT REQUIREMENTS

Process station input voltage 208 VAC, 10kVA, 50/60 Hz, 3PH

Normal operating current 10 to 21 A

Peak operating current 25 A

On/Off fuse rating 35 A

Power cable (for 3-phase power)(3 Delta Conductors + P .E . connection)

Wire size according to local electrical code . Cable drop from ceiling over rear-left side of process station

Power cable circuit breaker wiringphase 1 to L1phase 2 to L2phase 3 to L3

• The 3-phase power cable and cable gland (cord grip) are customer-supplied and installed . The cable feeds through the access port on the top of the printer .

• Connect the power cable ground wire to the ground bus bar in the printer’s power disconnect box .

• Connect the printer to a dedicated power circuit .

9 ELECTRICAL REQUIREMENTS

208V 3Phase Line input

Example of printer incoming power line connection

MAIN DISCONNECT

Printer line wiring

Page 21: ProX® SLS 6100 - 3D Systemsinfocenter.3dsystems.com/product-library/sites/default/... · 2019. 3. 1. · process station must be flat and vibration-free. The room must be air-conditioned,

3D Systems, Inc. 18 p/n 76-D022 Rev. B

SLS SINGLE MQC SYSTEM POWER REQUIREMENTS

COMPONENT REQUIREMENTS

Input voltage (Single Phase) 208-230VAC, 50/60Hz, 1PH

Normal operating current 1 .6 A

Peak operating current 4A

On/Off breaker rating 5A

Power Cable IEC320-C19 Plug 16AWG (ø1 .29mm)(2 Conductors + P .E . Connection)

Maximum Room Ambient Temperature 27 °C

GROUNDING REQUIREMENTSAll connections between powered equipment and the power panel must be grounded as shown in the diagram below .

< 5 Ω < 5 Ω

< 5 Ω < 5 Ω

< 5 Ω < 5 Ω

< 5 Ω < 5 Ω

ProX 500SLS System

MQC

Non-IgnitonVacuum

BeadBlaster

MainPower Panel

PowerSubpanels

Frame Ground

Page 22: ProX® SLS 6100 - 3D Systemsinfocenter.3dsystems.com/product-library/sites/default/... · 2019. 3. 1. · process station must be flat and vibration-free. The room must be air-conditioned,

3D Systems, Inc. 19 p/n 76-D022 Rev. B

NITROGEN SUPPLY OPTIONSUse one of the following nitrogen supply methods to meet the requirements:

• Liquid or bottled (gaseous) nitrogen with auto-switching manifold

• Nitrogen generator

• Bulk nitrogen tank

NOTE: Nitrogen supply systems are customer supplied and installed . 3D Systems does not service nitrogen supply equipment except for 3D Systems Nitrogen generator .

A properly functioning nitrogen supply system that meets the requirements listed below must be in place before the ProX® SLS 6100 System installation .

NITROGEN SUPPLY REQUIREMENTS

COMPONENT REQUIREMENT

Purity 99%

Nitrogen line fittings Inlet: ¼ inch Barbed Hose Fitting

Continuous flow 10 slpm (21 scfh) for length of build

Purge flow 50 lpm (106 cfh) for 15 minutes

Exhaust Must exhaust to outside at pressure 0 .0025 bar (1 .0 in H2O)

Weekly consumption 140 m3 (4944 ft3) of N2 gas based on 24 h/day operation with 7 purge cycles

N2 Generator O2 ExhaustThe nitrogen generator separates nitrogen from ambient air (CDA required), creating two air streams; N2 supply and O2 waste . Both exit at the bottom of the generator .

The N2 supply stream is greater than 99% nitrogen . The O2 waste stream is less than 40% oxygen . If the SLS process room meets the air exchange requirements, it is safe to vent the O2 waste stream into the room .

NITROGEN SUPPLY AND EXHAUST LINESNitrogen supply and exhaust lines must be in place before ProX® SLS 6100 System installation . Follow these guidelines for nitrogen supply and exhaust lines:

• Route nitrogen supply lines through the ceiling.

• Locate the drops over the right side of the process station (viewed from the front).

NOTE: Keep the nitrogen lines—especially the exhaust line—as short as possible to ensure proper pressure .

COMPRESSED AIR REQUIREMENTS

COMPRESSED AIR ProX® SLS 6100 3D PRINTER MQC SYSTEM 3D SYSTEMS N2 GENERATOR (OPTIONAL)

Connection Type 1/4” Barbed Hose Fitting 1/4” Barbed Hose Fitting

Industrial interchange male coupling plug:1/4 inch coupling size, air inlet at top of

nitrogen generator

Flow Rate 35 slpm 130 slpm 270 lpm (572 cfh)

Supply Pressure 6 bar (90 psi) 6 bar (90 psi) 620-690 kPa (90-100 psi)

Quality CDA (Clean Dry Air)ISO 8573 .1 Class 2 .2 .2

CDA (Clean Dry Air)ISO 8573 .1 Class 2 .2 .2

CDA (Clean Dry Air)ISO 8573 .1 Class 2 .2 .2

10 NITROGEN AND COMPRESSED AIR REQUIREMENTS

Page 23: ProX® SLS 6100 - 3D Systemsinfocenter.3dsystems.com/product-library/sites/default/... · 2019. 3. 1. · process station must be flat and vibration-free. The room must be air-conditioned,

3D Systems, Inc. 20 p/n 76-D022 Rev. B

The SLS equipment uses ethernet ports on the ProX® SLS 6100 Printer and SLS Single MQC System to send and receive powder transfer and system status messages . There is one ethernet connector on the ProX® SLS 6100 system that is connected to the SLS Single MQC and another that is connected to the facility’s LAN .

The ethernet connectors are RJ-45, using Category 5 unshielded twisted pair; 10BaseT, 100BaseT cables .

LAN 1 LAN 2

Customer LAN

Electrical Box

ProX SLS 6100 3D Printer

SLS Single MQC System

Hub

11 NETWORK REQUIREMENTS

Page 24: ProX® SLS 6100 - 3D Systemsinfocenter.3dsystems.com/product-library/sites/default/... · 2019. 3. 1. · process station must be flat and vibration-free. The room must be air-conditioned,

3D Systems, Inc. 21 p/n 76-D022 Rev. B

12 3D CONNECT REQUIREMENTS

3D Connect Service:

This printer is 3D Connect capable . For more information, please visit the link below:

http://infocenter .3dsystems .com/service/3d-connect-service/setup-guide/printer-setup/prox-6100-and-500-printer-setup

Requirements: Equipment Supplied by 3D Systems

• 3D Connect Adapter with international power converters

Equipment required to connect a machine (not included in box)

• Cat5 Network Cable

Special Notes:A dedicated port with a static IP address will need to be allocated and configured by your IT department

The adapter must be network reachable by the printer that is to be installed

The adapter will need external internet access to reach analytic servers

The adapter will require an electrical power outlet

Configuration: The 3D Connect adapter will need to be configured by your local Field Service Engineer using specific information from your network environment .

Please be prepared to provide the following information on the dedicated port to configure the adapter

• Dedicated Static IP Address

• DNS Server Name

• Subnet Mask

• Default Gateway Addresses

For more information on availability, please contact your salesperson or service provider at 3D Systems .

Page 25: ProX® SLS 6100 - 3D Systemsinfocenter.3dsystems.com/product-library/sites/default/... · 2019. 3. 1. · process station must be flat and vibration-free. The room must be air-conditioned,

3D Systems, Inc. 22 p/n 76-D022 Rev. B

The shipments consist of several numbered pallets or crates of equipment and one crate of accessories . Check the count labels on the pallets and crates to verify that your shipment is complete .

The weights and dimensions in the domestic shipment example below include the equipment plus the pallet or crate . Shipping configurations may vary from this example.

13 SHIPPING WEIGHTS AND DIMENSIONS

SYSTEM COMPONENT WEIGHTS AND DIMENSIONSThis table lists the “bare” (unpacked) dimensions and weights of all required and optional ProX SLS 6100 3D Printer System and part finishing equipment.

ProX® SLS 6100 3D PRINTER SYSTEM COMPONENT WEIGHTS AND DIMENSIONS

Component Weight2 Width Depth Height

Printer Station11360 kg 174 cm 123 cm 236 cm

3000 lb 69 in 48 in 93 in

SLS Single MQC System800 kg 238 cm 99 cm 236 cm

1764 lb 93 .9 in 39 in 93 in

Transformer, Step Down, 240/208 VAC, 3-phase, 60 Hz, 10 kVA

127 kg 56 cm 23 cm 41 cm

280 lb 22 in 9 in 16 in

Transformer, Step Down, 385-415/208V, 3-phase, 50 Hz, 10 kVA CE

approved

127 kg 80 cm 75 cm 60 cm

280 lb 32 in 30 in 24 in

Dust Extractor453 .6 kg 76 .2 cm 165 .1 cm 188 cm

1,000 lb 30 .0 in 65 in 74 in

Standard Volume Sifter34 kg 53 cm 58 cm 86 cm

75 lb 24 in 40 in 34 in

Nitrogen Generator113 kg 25 cm 56 cm 97 cm

250 lb 10 in 22 in 38 in

Bead Blaster68 kg 66 cm 102 cm 160 cm

150 lb 26 in 40 in 63 in

Vacuum Cleaner65 kg 60 cm 53 cm 80 cm

139 lb 23 .6 in 31 .5 in 51 .2 in

1 . Shipping weights are estimates .

2 . Printer station dimensions and weight include panels

Page 26: ProX® SLS 6100 - 3D Systemsinfocenter.3dsystems.com/product-library/sites/default/... · 2019. 3. 1. · process station must be flat and vibration-free. The room must be air-conditioned,

3D Systems, Inc. 23 p/n 76-D022 Rev. B

This accessories crate contains the following items:

ProX® SLS 6100 3D PRINTER SYSTEM SHIP KIT CONTENTS

Qty Item No . Description

2 104138-00 QUICK-DISCONNECT HOSE COUPLING

2 104194-00 BARBED HOSE FITTING, 1/4 HOSE ID, 1/4 NPT

50 104594-00 Tube 3/4 Inch Static Disipative

2 106029-00 EPM Filter, Pleated

2 106035-00 Filter, 2-stage, 5 microns

1 110008-00 NYLON CABLE TIES; 11” LG; .18” WIDE; BLACK; 100 PIECES/ PACK

5 120307-00 Mylar, Printed Calibration

1 132349-00 Cable, O2 ESR Alarm 50 Foot

1 132350-00 Cable, O2 ESR Alarm Jumper

1 132572-00 Lens Tissue

1 132896-00 CAT5E SHIELDED CABLE 50 ft - GRAY

1 23099-107-00 DRIVER,TORXPLUS,STR,IP20

1 4100-01430 Dust Cloths, Orange (Pack of 50)

2 4100-01431 Swabs, Anti-Static Foam (pack of 50)

1 4100-02518 BOTTLE,ETHANOL

2 532855 Pleated Media - Carbon Filter

3 7000-03145 Mylar, Black, Photographic

2 76-0093 FILTER MEDIA ELECTRICAL ENCLOSURE, ROOK

2 76-0313 IPM LASER AIR FILTER

2 76-0502 IPM AIR FILTER, CASE

1 132573-00 Ball Point Hex Driver, Long Length, 2 .5mm (McM #5497A72)

1 132897-00 Ball Point Hex Driver, Long Length, 4mm (McM #5497A74)

14 PROX® SLS 6100 SHIP KIT

Page 27: ProX® SLS 6100 - 3D Systemsinfocenter.3dsystems.com/product-library/sites/default/... · 2019. 3. 1. · process station must be flat and vibration-free. The room must be air-conditioned,

3D Systems, Inc. 24 p/n 76-D022 Rev. B

15 SINGLE MQC SHIP KIT

This accessories crate contains the following items:

SINGLE MQC SHIP KIT CONTENTS

Qty Item No . Description

1 104138-00 QUICK-DISCONNECT HOSE COUPLING

1 104139-00 HOSE CLAMP

1 104194-00 BARBED HOSE FITTING, 1/4 HOSE ID, 1/4 NPT

1 104566-00 Sinterstation Pro IRS ESD Tubing Upgrade Kit

1 104593-00 Fitting Compression .75 x .75 MPT Brass

1 106299-00 Sinterstation Pro 3/4" OD Tube Compression Sleeve

1 132350-00 Cable, O2 ESR Alarm Jumper - DDH

1 132725-00 KIT, PROX 500, DUST COLLECTOR

1 132750-00 PROX MQC WEIGHT ERROR TAG

1 4100-02381 SCOOP,PL,8 .5X4 .75,BARREL

1 4100-02391 DOUBLE ENDED SPATULAS/CARVERS (SET OF 12)

1 4100-02398 BRUSH,BRISTLE,1X3/4,HOG BRISTLE

1 4100-02399 BRUSH,ACID,SIZE 1X2

1 4100-03544 BRUSH,PAINT,NYL BRISTLE, 3 IN

1 122389-00 FLASH DRIVE, 8GB USB 2 .0, FIT SIZE

1 122092-00 PROBE, THERMOCOUPLE, TYPE K, 12IN

1 132566-00 BRUSH, HANDLED NYLON

1 77-0278 MQC Power Cord

Page 28: ProX® SLS 6100 - 3D Systemsinfocenter.3dsystems.com/product-library/sites/default/... · 2019. 3. 1. · process station must be flat and vibration-free. The room must be air-conditioned,

p/n 76-D022 Rev. B

16 ProX SLS 6100 3D PRINTER FACILITY REQUIREMENTS POSTER

Rev_B