Proven Performance for cost-effective sterilization Using our original, innovative gas plasma technology, the sterraD® 100s system has been a pioneer in low-temperature sterilization for nearly twenty years. recognized for its proven performance, the sterraD® 100s system is your cost-effective choice for dry, low-temperature sterilization.
SAFETY
• Lowtemperaturegasplasmaefficientlyeliminatestracesofresidualhydrogenperoxidefrommaterialsanddevicesandtheprocessby-productsarenon-toxicoxygenandwatervapor.
SIMPLICITY
• Easeofuse:one-buttonoperation
• Nocostlyplumbing,ventilation,ormonitoringrequired
COMPATIBILITY
• Provenclaims*forawiderangeofmaterialandlumens
• Capableofsterilizingrigidandflexibleendoscopes,cameras,lightcables,batteries,lenses,probes,microsurgicalandgeneralsurgeryinstruments
Allrightsreserved.STERRADisaregisteredtrademarkofAdvancedSterilizationProducts.
*PleaserefertotheSTERRAD100SSterilizationSystemUser’sGuidepriortouse.Consultwiththemedicaldevicemanufacturerofinstrumentsorendoscopesyouintendtosterilizewithanyquestionsregardingmaterialscompatibility.
†PleasecontactyourASPrepresentativetodeterminemaximumchambercapacitybasedonyourfacility’sparticularsterilizationloadconfiguration(s). AD-100058-01-CT_A
FOR MORE INFORMATION OR TO PLACE AN ORDER:PLEASECONTACTYOURLOCALASPREPRESENTATIVE
TECHNICALSPECIFICATIONS
ShortCycle:54minutesLongCycle:72minutes
Lessthan55°C
Height 1664mm Width 762mm Depth 1046mm Weight 350kg
Confi guration Circular Chamber Volume 173L†
Shelf Dimensions Uppershelf:700mmx425mm Lowershelf:760mmx325mm
POWERUSAGE Connections 380-415VAC,50Hz,10A,3-phasecircuitwithseparate neutralandgroundconductors.CBAphaserotation
SERVICEREQUIREMENTS Inoperation,theSTERRAD®100SSystemshouldnotbeplacedcloserthan5cmtoawallattherearand/orsidesofthesystem.Thesterilizershouldbeinstalledinaspaceofsufficientsizetopermitaccesstoallfoursidesofthesystemwhenitisrolledfromtherearand/orsidewallsareatadistanceof3m.Serviceaccessrequiresaminimumclearanceof1monallsidesofthesystem.
Temperature 10°Cto40°C Humidity 30-75%relativehumidity(non-condensing)
TOTALCYCLETIME
CYCLETEMPERATURE
DIMENSIONS&WEIGHT
STERILIZATIONCHAMBER
OPERATIONALENVIRONMENT
HYDROGENPEROXIDEGASPLASMATECHNOLOGYPlasma is generated to safely eliminate residual H2o2
SAFE FOR INSTRUMENTS
system byproducts are oxygen and water
SAFE FOR ENVIRONMENT
vaporized Hydrogen Peroxide (H2o2) is introduced into a vacuum chamber
Sterility Assurance Level: 10-6
Contact for Ireland :
ASPc/oJ&JMedicalIrelandAirtonRd,TallaghtDublin24,Ireland
T:+35314665200F:+35314665340
Contact for South Africa :
ASPc/oJ&JMedicalPty.Ltd.SAPOBox273,MidrandHalfwayHouse1685RepublicofSouthAfrica
T:+27112651120F:+27112651189
Contact for Middle East :
ASPc/oJ&JMedicalMiddleEastDubaiHealthcareCity,J&Jbuilding,3rdfloorPOBox505080,Dubai,UnitedArabEmirates
T:+97144297235F:+97144297250
Contact for UK :
ASPc/oJ&JMedicalLtd.PinewoodCampus,NineMileRideWokinghamBerkshireRG403EW,England
T:+441344871081F:+441344871171
Contact for Egypt:
Johnson&JohnsonMedicalEgyptFloridaMall5thFloor1229SquareElSheikhAliGadElHakSt.HeliopolisCairo,Egypt
T:+20222685026F:+20222684674