9
Proposed Conventional Sextupole for Installation at A0 Introduction (Dean Still) Reasons for installation- Reduce I in S6 feeddown sextupole circuit at injection and possibly up the ramp. Magnetic Parameters – ( Vladimir Shiltsev, Dave Harding, Yuri Alexahin) Does the magnet need to ramp? Ramp tests. Possibly of building laminated version Mechanical – (Mike Mcgee, Bill Robotham) Will it fit into the A0 space? Requires stand modification. Requires entire magnet rotated +/- 30 degrees. Electrical/Power Supply – (Wolff) Need to know Installation – (Jim Volk) Mechanical Cable pulls Controls Water Manifold

Proposed Conventional Sextupole for Installation at A0 Introduction (Dean Still) Reasons for installation- Reduce I in S6 feeddown sextupole circuit at

Embed Size (px)

DESCRIPTION

Proposed Location – A0 F49 Install Here

Citation preview

Page 1: Proposed Conventional Sextupole for Installation at A0 Introduction (Dean Still) Reasons for installation- Reduce I in S6 feeddown sextupole circuit at

Proposed Conventional Sextupole for Installation at A0

Introduction (Dean Still)Reasons for installation- Reduce I in S6 feeddown sextupole circuit at injection and possibly up the ramp.

Magnetic Parameters – ( Vladimir Shiltsev, Dave Harding, Yuri Alexahin)Does the magnet need to ramp?Ramp tests.Possibly of building laminated version

Mechanical – (Mike Mcgee, Bill Robotham)Will it fit into the A0 space?Requires stand modification.Requires entire magnet rotated +/- 30 degrees.

Electrical/Power Supply – (Wolff)Need to know

Installation – (Jim Volk)MechanicalCable pullsControlsWater Manifold

Page 2: Proposed Conventional Sextupole for Installation at A0 Introduction (Dean Still) Reasons for installation- Reduce I in S6 feeddown sextupole circuit at

Proposed Conventional Sextupole for Installation at A09/12/03 Meeting

Magnetic Parameters – (Dave Harding)Look at measurements preformed.

Mechanical – (Mike Mcgee, Bill Robotham)Look at proposed mech. changes from Bill.(Dean)

Electrical/Power Supply – (Wolff)Update to power supply needs.Need to know ripple requirements.

Installation – (Jim Volk)MechanicalCable pullsControlsWater Manifold

Page 3: Proposed Conventional Sextupole for Installation at A0 Introduction (Dean Still) Reasons for installation- Reduce I in S6 feeddown sextupole circuit at

Proposed Location – A0

antiprotons

E0

target

IR

proton s

D0

A0

collimator

IR

B0

C0

F0

F49

Install Here

Page 4: Proposed Conventional Sextupole for Installation at A0 Introduction (Dean Still) Reasons for installation- Reduce I in S6 feeddown sextupole circuit at

Location to Install

Install upstream of A0 abort block

Floor is ground up

F49

Page 5: Proposed Conventional Sextupole for Installation at A0 Introduction (Dean Still) Reasons for installation- Reduce I in S6 feeddown sextupole circuit at

Other Sextupole Options

TESLA

MI ISA MR SEXTUPOLE

Page 6: Proposed Conventional Sextupole for Installation at A0 Introduction (Dean Still) Reasons for installation- Reduce I in S6 feeddown sextupole circuit at

Accumulator Skew Sextuple

Length: 30 in.Bore: 4 in.Coil: 21 turnsHeight: 15 ¾ in.

If turned ,~10 3/4 in. from beam center to edge of steel.

Will need to cut feet off and rotate.

Page 7: Proposed Conventional Sextupole for Installation at A0 Introduction (Dean Still) Reasons for installation- Reduce I in S6 feeddown sextupole circuit at

Accumulator Skew Sextupole IVladimir Kashikhin-Technical Review, March 19, 1999

Sextupole Corrector Parameters

Type of the magnet skew sextupole Integrated strength 80 T/mMagnet aperture 2.625 in ( 66.675 mm )Magnetic core length 30 in ( 0.762 m )Field quality (deviation fromthe ideal sextupole field) < 0.1 %Good field region diameter 4 in ( 101.6 mm )Beam pipe diameter ( OD ) 4 in (101.6 mm )Copper conductorConductor dimension ( MA-186587) 0.4096 in ( 10.404 mm)Cooling channel diameter 0.229 in ( 5.83 mm )Cu effective cross-section 81.67 mm²Cu resistivity at 20 °C 0.018 Ω mm²/mTotal length per magnet 240 mTotal weight per magnet 175 kg

Page 8: Proposed Conventional Sextupole for Installation at A0 Introduction (Dean Still) Reasons for installation- Reduce I in S6 feeddown sextupole circuit at

Accumulator Skew Sextupole IIVladimir Kashikhin-Technical Review, March 19, 1999

Winding ParametersNumber of turns per coil 21Number of coils 6Length of the turn 1.92 m Coil resistance at 20 ºC 8.9 mΩWinding resistance at 20 ˚C 54 mΩVoltage drop per magnet 13.5 V( + 10% extra for current leads)Maximum current 200 APower dissipation per magnet 2440 WNumber of the water cooling circuits 1Water pressure drop 0.4 MPaWater flow 0.018 l/sWater temperature rise 32 ˚C Ferromagnetic Core ParametersCore material low carbon steel AISI 1006 Core length 30 in ( 762 mm ) Core weight 580 kgTotal magnet weight 800 kg

Page 9: Proposed Conventional Sextupole for Installation at A0 Introduction (Dean Still) Reasons for installation- Reduce I in S6 feeddown sextupole circuit at

Spare SSS Magnet at TPL

Serial #: SSS001-1