Upload
cesar-gomes-de-souza
View
217
Download
0
Embed Size (px)
Citation preview
7/27/2019 PRONTO- Ventilador axial - Relatrio I
1/24
UNIVERSIDADE FEDERAL DA GRANDE DOURADOS
FACULDADE DE ENGENHARIAS
CURSO DE ENGENHARIA DE ENERGIA
MQUINAS DE FLUIDOS
VENTILADOR AXIAL
DOURADOS-MS
7 DE DEZEMBRO DE 2012
7/27/2019 PRONTO- Ventilador axial - Relatrio I
2/24
Brbara Lanzarini Bambil
Csar Augusto Gomes de Souza
Jssica Beatriz Olivi
Leonardo Freire Marques
VENTILADOR AXIAL
DOURADOS-MS
7 DE DEZEMBRO DE 2012
RELATRIO DE AULA AVALIATIVO,DESENVOLVIDO NA DISCIPLINAMQUINAS DE FLUIDOS, APLICADO
REA DE ENGENHARIA DE ENERGIA,PROPOSTO PELO PROFESSOR DR.ROBSON LEAL DA SILVA.
7/27/2019 PRONTO- Ventilador axial - Relatrio I
3/24
1. Objetivos
Capacitao na realizao de medidas de grandezas dimensionais (m,
metro) e analisar os resultados do ponto de vista estatstico e de adequao da
instrumentao utilizada para as medidas que sero obtidas.
2. Introduo
Mquinas de fluidos so equipamentos que tanto realizam trabalho
sobre o fluido, como extraem-no (ou potncia) do fluido. Podem ser
classificadas em dois tipos: mquinas de fluidos de deslocamento positivo ou
dinmicas, na qual a transferncia de energia acompanhada por uma
mudana de volume, devido o movimento da fronteira na qual o fluido est
confinado. E as mquinas de fluxo ou turbomquinas que lidam de maneira
dinmica com o fluido direcionando-o atravs de lminas ou ps ligadas a um
elemento rotativo. Diferem das mquinas de deslocamento positivo, pois no
apresentam um volume fechado e o fluido escoa atravs dela.
Muito utilizadas na gerao de energia e em diversas aplicaes
industriais, as turbomquinas compreendem turbinas hidrulicas, vapor ou gs,
ventiladores, bombas centrifugas, turbocompressores entre outros. Seus
componentes principais so o rotor, onde acontece a transformao de energia
mecnica em energia de fluido, ou de energia de fluido em energia mecnica,
o rgo principal de uma mquina de fluxo. constitudo de certo nmero de
ps giratrias que dividem o espao em canais, por onde circula o fluido de
trabalho. E o sistema diretor, que coleta o fluido e dirigi-o para um caminho
determinado. Funo esta muitas vezes acompanhada por outra detransformador de energia.
Ventiladores so estruturas mecnicas utilizadas para converter energia
mecnica de rotao, aplicada em seus eixos, em aumento de presso do ar.
Num ventilador, a alterao na densidade entre a admisso e a descarga da
mquina to pequena que o gs pode ser considerado como um fluido
incompressvel (diferenas de presso at 10kPa ou 1000mmca).
O presente trabalho traz a anlise de um ventilador axial, mquina defluxo do tipo operatriz, ou seja, que fornece energia ao fluido; de reao, pois
7/27/2019 PRONTO- Ventilador axial - Relatrio I
4/24
os canais constitudos pelas ps mveis do rotor tm a forma de difusores
havendo aumento, da presso do fluido que passa atravs do rotor. O termo
axial diz respeito a trajetria do fluido atravs do rotor, a qual acontece numa
direo paralela (axial) ao eixo.
Ventiladores axiais so usados para promover o escoamento de gases e
vapores e formam o grupo ao qual pertencem os ventiladores residenciais
comuns, bem como aqueles utilizados em tuneis rodovirios e ferrovirios,
minas, estaes de metro, projetos hidroeltricos, etc. Seu uso se faz sempre
que se buscam grandes vazes de ar com pequena perda de carga.
Os principais tipos de ventiladores axiais so:
Axial propulsor, os quais geram grandes vazes com baixas
presses. So de fcil construo o que resulta em custos baixos. Instalado
sem duto, geralmente empregado na ventilao geral diluidora.
Axial comum possui ampla calota central, que possibilita sua
utilizao a presses mais elevadas. frequentemente usado em ventilao de
minas subterrneas e, em algumas ocasies, em indstrias. Nesse tipo de
ventilador, a forma das ps muito importante, e eles no devem ser usados
onde haja risco de eroso e corroso.
Tubo-axial trabalha com presses maiores que o ventilador axial
propulsor, com um rendimento maior. Isto possvel devido ao rotor com ps
de melhor perfil aerodinmico e a presena do tubo axial. Para aumentar ainda
mais a eficincia, podem ser afixadas no interior do tubo axial, aletas
estabilizadoras do fluxo.
Erros e incertezas
Segundo Toginho Filho e Andrello (2009) um dos princpios bsicos dafsica diz: No se pode medir uma grandeza fsica com preciso absoluta, ou
seja, qualquer medio, por mais bem feita que seja, sempre aproximada.
De acordo com o princpio descrito no pargrafo anterior, o valor medido
nunca representa o valor verdadeiro da grandeza, pois este nunca conhecido
com total certeza. Quando este resultado (nmero e unidade) vai ser aplicado
ou registrado necessrio saber com que confiana se pode dizer que o
nmero obtido representa a grandeza fsica. O valor medido ou o resultadodeve ser expresso com a incerteza da medida, utilizando uma representao
7/27/2019 PRONTO- Ventilador axial - Relatrio I
5/24
em uma linguagem universal, fazendo com que seja compreensvel a outras
pessoas.
Os erros podem ser classificados em dois grandes grupos: erros
sistemticos ou erros aleatrios
Os erros sistemticos so aqueles que resultam das discrepncias
observacionais persistentes, tais como erros de paralaxe. Os erros sistemticos
ocorrem principalmente em experimentos que esto sujeitos a mudanas de
temperatura, presso e umidade. Estas mudanas esto relacionadas a
condies ambientais.
Os erros sistemticos podem e devem ser eliminados ou minimizados
pelo experimentador. Isso pode ser feito, observando se os instrumentos esto
corretamente ajustados e calibrados, e ainda se esto sendo usados de forma
correta na interligao com outros instrumentos, na montagem experimental.
Existe um limite abaixo do qual no possvel reduzir o erro sistemtico
de uma medio. Um destes erros o de calibrao, diretamente associado ao
instrumento com o qual se faz a medio. Este tipo de erro tambm chamado
erro sistemtico residual.
Geralmente, o erro de calibrao (residual) vem indicado no instrumento
ou manual, pelo fabricante; o limite dentro do qual o fabricante garante os
erros do instrumento.
Os erros aleatrios (ou estatsticos) so aqueles que ainda existem
mesmo quando todas as discrepncias sistemticas num processo de
mensurao so minimizadas, balanceadas ou corrigidas. Os erros aleatrios
jamais podem ser eliminados por completo.
3. Metodologia
3.1. Materiais
Os equipamentos da FIGURA 1 foram utilizados para aferir as
medidas do experimento de ventilador axial. Como pode ser visualizado esto
enumerados: (1) Temo - Higrmetro Digital HT-600, (2) Tacmetro digital TD-
812, (3) Termo- Higro- Barmetro digital da Lutron, (4) Trena de bolso T34-5 (5)
Termo- Higro- Anemmetro digital THAB-500, (6) Cronmetro da Instrutherm e
(7)Wattmetro digital porttil WD-950.
7/27/2019 PRONTO- Ventilador axial - Relatrio I
6/24
FIGURA 1. Equipamentos de aferio de dados do experimento.
Segue na Tabela 1 as especificaes dos equipamento utilizados paramedio das grandezas. O ventilador axial de mesa utilizado como a mquinade fluxo do experimento, Ventilador da Loren Sid, dimetro da p 45 cm,modelo: Turbo M2 PT 3 ps e potncia de 60 W. Foi utilizado um tnel devento com comprimento de 3m e dimetro de 60 cm.
TABELA 1. Equipamentos utilizados para realizar medidas.
7/27/2019 PRONTO- Ventilador axial - Relatrio I
7/24
As medidas das grandezas que influenciam no ambiente onde foi
realizado o experimento esto listadas na Tabela 2.
TABELA 2. Grandezas de influncia no ambiente
Na FIGURA 2, mostra o esquema do aparato experimental usado, quesegue as especificaes da metodologia do INMETRO (2011) para
determinao da eficincia energtica, com a alterao no nmero de pontos
de coleta dos dados de velocidade na sada do tnel.
FIGURA 2. Aparato experimental. (INMETRO, 2011).
3.2. Etapas
Antes de iniciar o experimento foi necessrio deixar o ventilador ligado
por um tempo maior ou igual a 10 minutos para que se adquirisse o regime
permanente do escoamento. Atravs do termo-higro-barmetro, trs grandezas
puderam ser aferidas: presso (hPa), temperatura (C) e umidade relativa (%)
ambiente, antes e depois da realizao do experimento.
7/27/2019 PRONTO- Ventilador axial - Relatrio I
8/24
7/27/2019 PRONTO- Ventilador axial - Relatrio I
9/24
FIGURA 4. Entrada do tnel de vento.
3.3. Memorial de clculo
No programa computacional EXCEL (2007) foram calculados os valores
mdios e os desvios padres das medidas registradas durante o experimento.
O resultado de uma srie de Nmedies pode ser escrito como em (1).
Conforme a referncia HENN (2006) que estabelece o clculo da vazo
mssica do rotor para uma mquina de fluxo axial est expresso em (2).
[ ]
7/27/2019 PRONTO- Ventilador axial - Relatrio I
10/24
: vazo mssica do rotor (kg/s): velocidade meridional absoluta aps o rotor (m/s): dimetro externo (m)
: dimetro interno (m)
: massa especfica do ar.Segundo FOX et al. (2010) o nmero adimensional de Reynolds
determinado como na equao (3).
: viscosidade dinmica do ar a 34,3C (307,3K), 1.88.10-5 N.s/m2(INCROPERA, et al., 2006)
A equao de Bernoulli foi utilizada para calcular a perda de carga no
escoamento, a equao (4) pode ser obtida segundo FOX et al. (2007).
: perda de carga, em J;: velocidade na sada do tnel, em m/s.
Segundo o Henn (2006) a velocidade tangencial calculada por Eq. (5),
a energia de presso esttica calculada pela equao (6), a energia
especfica de presso dinmica ou de velocidade (7), o trabalho especficofornecido pelas ps do rotor (8) e energia disponvel pelo fluido na entrada da
mquina (9)
: velocidade angular, rad/s;: raio interno do rotor, m.
7/27/2019 PRONTO- Ventilador axial - Relatrio I
11/24
: energia de presso esttica, em J/kg;
: velocidade tangencial de um ponto na entrada do rotor, em m/s;: velocidade tangencial de um ponto situado na entrada do rotor, em m/s;: velocidade relativa de uma partcula fluida na entrada do rotor, em m/s;: velocidade relativa de uma partcula fluida na entrada do rotor, em m/s;
: energia especfica de presso dinmica ou de velocidade, J/kg;: velocidade absoluta de uma partcula fluida na sada do rotor, em m/s;: velocidade absoluta de uma partcula fluida na entrada do rotor, em m/s.
: salto energtico ou trabalho especfico fornecido pelas ps do rotor aofluido, em J/kg;: componente tangencial da velocidade absoluta para a sada do rotor, emm/s;
: componente tangencial da velocidade absoluta para a entrada do rotor, emm/s.
: energia disponvel pelo fluido na entrada da mquina, J/kg: energia especfica referente s perdas hidrulicas.
O coeficiente de presso pode ser obtido por Eq. (10) e o coeficiente de
vazo por (11).
7/27/2019 PRONTO- Ventilador axial - Relatrio I
12/24
: coeficiente de presso, adimensional;
: salto energtico especfico, J/kg;
: coeficiente de vazo, adimensional;: vazo da mquina, em m3/s.
O raio mdio foi calculado atravs da Eq. (12). (ANDRADE e LEAL da
SILVA, 2012).
: raio externo, em m;
: raio interno, em m.Considerou-se o ar como gs ideal, assim foi obtido a massa especfica
atravs da Eq. (13).
: presso local, aferida pelo barmetro, em hPa: massa especfica do ar a 34,3C (307,3 K), considerando-o como um gsideal, 1.086001376 kg/m3;
R: constante dos gases ideais, 287 J/kmolK (ANDRADE e LEAL da SILVA,
2012).
A potncia ativa foi calcula atravs da Eq. (14).
7/27/2019 PRONTO- Ventilador axial - Relatrio I
13/24
: potncia ativa, em W;: diferena de potencial, em V;: corrente, em A.
Segundo Andrade e Leal da Silva (2012), a potncia de escoamento do
ventilador foi dado por Eq. (15).
O clculo da eficincia global do ventilador () dado por (16).
Segundo Toginho Filho e Andrello (2009) a incerteza padro da
grandeza de sada dada pela Eq. (17).
()
() ()
Consideraes
Segundo Henn (2006) para rotores axiais ou tangenciais, u4=u5, pois o
fluxo entra e sai na mesma direo.
Para condies ideais Cm4=Cm5 =C4 em mquinas axiais de fluxogeradoras, porem para as condies reais deste experimento foi considerado
Cm4 Cm5, sendo 4= 90 e 5 = 13 (medido na sada do rotor). Segue abaixo
a FIGURA 5 representando esquematicamente os tringulos de velocidade.
7/27/2019 PRONTO- Ventilador axial - Relatrio I
14/24
FIGURA 5. Tringulos de velocidade.
4. Resultados e Discusses
As tabelas abaixo apresentam as grandezas de interesse obtidas no
experimento, registradas (TABELA 3) e calculadas (TABELA 4).
7/27/2019 PRONTO- Ventilador axial - Relatrio I
15/24
Antes do
rotor
Depois do
rotor
Sada do
tnel
Rotao 1
(rpm) Corrente 1 (A)
Antes do
rotor
Depois do
rotor
Sada do
tnel
Rotao 2
(rpm) Corrente 2 (A)
Antes do
rotor
Depois do
rotor
Sada do
tnel
Rotao 3
(rpm)
Corrente 3
(A)
1 0,30,0378 1,90,1163 0,60,0258 373,82,5908 0,52960,0030 0,50,0458 30,1454 10,0516 562,42,6957 0,67950,0029 0,80,0458 3,90,2131 1,50,1356 723,53,9641 0,7770,0029
2 0,40,0378 1,70,1163 0,60,0258 377,22,5908 0,52940,0030 0,60,0458 3,130,1454 1,10,0516 563,32,6957 0,68010,0029 0,80,0458 3,60,2131 1,10,1356 721,23,9641 0,7740,0029
3 0,30,0378 1,90,1163 0,60,0258 374,32,5908 0,52870,0030 0,60,0458 3,130,1454 1,20,0516 559,82,6957 0,68010,0029 0,80,0458 3,80,2131 1,40,1356 727,53,9641 0,7750,0029
4 0,30,0378 1,80,1163 0,60,0258 370,52,5908 0,52630,0030 0,60,0458 2,830,1454 1,10,0516 559,12,6957 0,68090,0029 0,70,0458 3,30,2131 1,50,1356 7213,9641 0,7750,0029
5 0,30,0378 1,90,1163 0,60,0258 3692,5908 0,52030,0030 0,60,0458 3,130,1454 1,10,0516 562,22,6957 0,68070,0029 0,80,0458 3,70,2131 1,50,1356 727,13,9641 0,7740,0029
6 0,30,0378 1,90,1163 0,60,0258 369,12,5908 0,52540,0030 0,60,0458 2,630,1454 1,10,0516 5642,6957 0,67980,0029 0,80,0458 3,60,2131 1,50,1356 716,93,9641 0,7740,0029
7 0,30,0378 20,1163 0,60,0258 373,62,5908 0,52090,0030 0,60,0458 30,1454 1,10,0516 564,82,6957 0,67960,0029 0,70,0458 3,90,2131 1,40,1356 719,23,9641 0,7730,0029
8 0,30,0378 20,1163 0,60,0258 373,12,5908 0,52340,0030 0,60,0458 2,90,1454 1,10,0516 564,82,6957 0,68080,0029 0,80,0458 40,2131 1,50,1356 716,23,9641 0,7740,0029
9 0,30,0378 20,1163 0,60,0258 374,22,5908 0,52290,0030 0,70,0458 30,1454 1,20,0516 561,52,6957 0,68090,0029 0,80,0458 40,2131 1,50,1356 720,33,9641 0,7750,0029
10 0,30,0378 20,1163 0,60,0258 371,32,5908 0,52150,0030 0,60,0458 2,90,1454 1,10,0516 566,52,6957 0,680,0029 0,80,0458 40,2131 1,40,1356 712,73,9641 0,7740,0029
11 0,30,0378 1,80,1163 0,70,0258 3702,5908 0,52460,0030 0,60,0458 2,80,1454 1,10,0516 567,92,6957 0,67140,0029 0,70,0458 3,90,2131 1,60,1356 720,23,9641 0,7750,002912 0,30,0378 20,1163 0,60,0258 3692,5908 0,52290,0030 0,60,0458 2,80,1454 1,10,0516 563,72,6957 0,67610,0029 0,80,0458 40,2131 1,70,1356 723,63,9641 0,7750,0029
13 0,30,0378 2,10,1163 0,60,0258 369,62,5908 0,52320,0030 0,60,0458 30,1454 1,10,0516 567,12,6957 0,67840,0029 0,70,0458 4,10,2131 1,60,1356 7223,9641 0,7640,0029
14 0,20,0378 1,90,1163 0,60,0258 368,92,5908 0,52360,0030 0,60,0458 2,90,1454 1,10,0516 566,82,6957 0,67290,0029 0,80,0458 40,2131 1,60,1356 7243,9641 0,7720,0029
15 0,30,0378 1,70,1163 0,60,0258 3702,5908 0,52260,0030 0,50,0458 3,10,1454 1,20,0516 566,72,6957 0,67820,0029 0,80,0458 3,80,2131 1,50,1356 723,33,9641 0,7730,0029
Mdia 0,30 1,91 0,61 371,57 0,5244 0,59 2,94 1,11 564,04 0,6786 0,77 3,84 1,49 721,25 0,7736
D. P. 0,0378 0,1163 0,0258 2,5908 0,0030 0,0458 0,1454 0,0516 2,6957 0,0029 0,0458 0,2131 0,1356 3,9641 0,0029
Antes do
rotor
Depois do
rotor
Sada do
tnel
Rotao 4
(rpm) Corrente 4 (A)
Antes do
rotor
Depois do
rotor
Sada do
tnel
Rotao 5
(rpm) Corrente 5 (A)
Antes do
rotor
Depois do
rotor
Sada do
tnel
Rotao 6
(rpm)
Corrente 6
(A)
1 10,0507 4,30,1352 1,90,0834 883,94,0766 0,8530,0029 1,10,0632 5,70,1839 2,40,1033 10545,5403 0,930,0016 1,50,0743 6,70,2320 2,70,0676 12573,6095 1,0640,0030
2 10,0507 4,70,1352 20,0834 8784,0766 0,8540,0029 1,20,0632 6,10,1839 2,50,1033 10425,5403 0,930,0016 1,60,0743 6,70,2320 2,80,0676 12573,6095 1,0650,0030
3 10,0507 4,60,1352 1,90,0834 881,74,0766 0,8580,0029 1,20,0632 5,80,1839 2,50,1033 10465,5403 0,9270,0016 1,60,0743 6,90,2320 2,80,0676 12573,6095 1,0610,0030
4 10,0507 4,70,1352 1,90,0834 879,84,0766 0,8530,0029 1,10,0632 6,10,1839 2,60,1033 10405,5403 0,9250,0016 1,70,0743 6,80,2320 2,80,0676 12553,6095 1,0620,0030
5 1,10,0507 4,30,1352 20,0834 883,34,0766 0,8540,0029 1,20,0632 5,90,1839 2,40,1033 10395,5403 0,9270,0016 1,60,0743 6,80,2320 2,90,0676 12583,6095 1,060,0030
6 1,10,0507 4,40,1352 20,0834 885,44,0766 0,8530,0029 1,20,0632 5,60,1839 2,50,1033 10425,5403 0,9290,0016 1,60,0743 7,30,2320 2,70,0676 12463,6095 1,0570,0030
7 1,10,0507 4,60,1352 1,90,0834 8844,0766 0,8510,0029 1,10,0632 5,50,1839 2,40,1033 10395,5403 0,9290,0016 1,60,0743 7,30,2320 2,80,0676 12503,6095 1,0590,0030
8 1,10,0507 4,60,1352 20,0834 875,34,0766 0,8510,0029 1,20,0632 5,90,1839 2,20,1033 10425,5403 0,930,0016 1,50,0743 7,30,2320 2,80,0676 12483,6095 1,0530,0030
9 10,0507 4,70,1352 20,0834 872,74,0766 0,8520,0029 1,10,0632 5,80,1839 2,30,1033 10545,5403 0,9270,0016 1,70,0743 7,30,2320 2,70,0676 12573,6095 1,0580,0030
10 10,0507 4,50,1352 1,80,0834 876,44,0766 0,850,0029 1,10,0632 5,70,1839 2,40,1033 10535,5403 0,9270,0016 1,70,0743 70,2320 2,80,0676 12533,6095 1,0570,0030
11 1,10,0507 4,60,1352 1,80,0834 8724,0766 0,8480,0029 1,20,0632 6,10,1839 2,50,1033 10485,5403 0,9280,0016 1,60,0743 7,10,2320 2,90,0676 12523,6095 1,0570,0030
12 1,10,0507 4,50,1352 1,80,0834 879,24,0766 0,8490,0029 1,20,0632 5,90,1839 2,30,1033 10505,5403 0,9270,0016 1,50,0743 7,20,2320 2,80,0676 12523,6095 1,0590,0030
13 10,0507 4,60,1352 20,0834 880,24,0766 0,8490,0029 1,10,0632 60,1839 2,30,1033 10475,5403 0,9270,0016 1,70,0743 7,20,2320 2,70,0676 12563,6095 1,060,0030
14 10,0507 4,60,1352 1,80,0834 879,94,0766 0,8570,0029 10,0632 60,1839 2,40,1033 10485,5403 0,9310,0016 1,70,0743 7,30,2320 2,70,0676 12543,6095 1,0590,0030
15 10,0507 4,70,1352 1,90,0834 8824,0766 0,8550,0029 1,10,0632 5,90,1839 2,40,1033 10395,5403 0,9280,0016 1,60,0743 7,10,2320 2,80,0676 12553,6095 1,0610,0030
Mdia 1,04 4,56 1,91 879,59 0,8525 1,14 5,87 2,41 1045,53 0,9281 1,61 7,07 2,78 1253,80 1,0595
D. P. 0,0507 0,1352 0,0834 4,0766 0,0029 0,0632 0,1839 0,1033 5,5403 0,0016 0,0743 0,2320 0,0676 3,6095 0,0030
TABELA 3. Grandezas registradas durante o experime nto
Velocidade na potncia 6 (m/s)
Velocidade na potncia 1 (m/s) Velocidade na potncia 2 (m/s) Velocidade na potncia 3 (m/s)
V elocidade na potncia 4 (m/s) Vel oci dade na potnci a 5 (m/s)
7/27/2019 PRONTO- Ventilador axial - Relatrio I
16/24
TABELA 4. Grandezas calculadas a partir dos dados obtidos
experimentalmente e seus respectivos erros.
A partir dos dados obtidos foram plotados os grficos a seguir paradeterminao das curvas caractersticas do escoamento.
FIGURA 6. Vazo mssica versus rotao.
O aumento da rotao implica no aumento da velocidade angular ()que est intimamente relacionada a velocidade tangencial () do fluidoconforme eq. (5), o aumento da velocidade tangencial aumenta a velocidade
absoluta () e consequentemente a componente meridional da mesma (valoraferido), logo como a vazo mssica funo de eq. (2) o aumento darotao implica no aumento da vazo mssica (FIGURA 6).
Potncia 1 Potncia 2 Potncia 3 Potncia 4 Potncia 5 Potncia 6
Vazo mssica (Kg/s) 0,31190,0161 0,48020,0201 0,62710,0295 0,74470,0187 0,95870,0255 1,15470,0321
Perda de Carga (J) 1,6380,1191 3,705750,1546 6,262750,2526 8,572750,1589 14,32440,2109 21,128250,2416
Reynolds 3,81E+6514,57 5,86E+61029,1436 7,65E+62701,94 9,09E+61661,72 1,17E+72058,29 1,41E+71347,47
Y_din (J/kg) 54,9890,1223 129,4740,1524 219,2160,2180 312,1390,1444 502,4900,1944 727,4570,2436
Y_est (J/kg) 31,9120,1223 80,7750,1524 137,5420,2180 193,2110,1444 323,2710,1944 468,8420,2436
Y (Trabalho Especfico) [J/Kg] 21,0760,2929 49,0960,3092 81,6710,4546 118,9060,4520 179,1870,6143 258,620,4210
Coeficiente de Presso () 10,10093591 10,21127852 10,3884954 10,16949318 10,84638186 10,88502356
Coeficiente de Vazo () 0,000150409 0,000152519 0,000155788 0,000151695 0,000164281 0,000164997
Potencia_p (W) 6,574492616 23,57357462 51,21883508 88,5522518 171,7817176 298,5956664
Y_real (J/kg) 15,82533052 41,3781102 71,68444461 107,3943705 164,2450963 240,3035802
Rendimento (%) 23,76430048 48,01047577 72,96334614 99,1974229 139,3408068 178,5949699
7/27/2019 PRONTO- Ventilador axial - Relatrio I
17/24
FIGURA 7. Diagrama de perda de carga distribuda versus rotao.
O aumento da rotao implicou no aumento da velocidade absoluta do
escoamento, o que implica numa perda maior de energia do fluido por atrito
com o tnel, assim caracterizando um aumento exponencial da perda de carga
com o aumento da rotao (FIGURA 7).
FIGURA 8. Diagrama de Reynolds versus rotao.
7/27/2019 PRONTO- Ventilador axial - Relatrio I
18/24
FIGURA 9. Diagrama de Reynolds versus perda de carga distribuda.
FIGURA 10. Diagrama de Reynolds versus vazo mssica.
Uma vez que o nmero adimensional de Reynolds eq. (3) diretamente
proporcional a velocidade meridional absoluta do escoamento, o aumento da
rotao implica no aumento de Reynolds (FIGURA 8) e por seguinte, vazo
mssica tambm aumenta com a rotao (FIGURA 10), logo, Reynolds
aumenta com o aumento da mesma tambm.
O nmero de Reynolds descreve o comportamento (laminar ou
turbulento) de um escoamento. O aumento deste significa um aumento da
turbulncia no escoamento e por conseguinte na perda de carga, desde que os
7/27/2019 PRONTO- Ventilador axial - Relatrio I
19/24
demais parmetros (rugosidade, massa especfica e viscosidade dinmica) no
variem, conforme FIGURA 9.
FIGURA 11. Diagrama de presso esttica versus rotao.
FIGURA 12. Diagrama de presso dinmica versus rotao.
7/27/2019 PRONTO- Ventilador axial - Relatrio I
20/24
FIGURA 13. Diagrama de presso total versus rotao.
As FIGURAS 11, 12 e 13 apresentam o aumento da energia de presso
do fluido, como esta est ligada ao aumento das velocidades componentes no
tringulo de velocidades e estas ao aumento da rotao, o crescimento desta
ltima, acarreta no aumento da energia de presso do fluido.
FIGURA 14. Diagrama de trabalho especfico versus vazo mssica.
O aumento da vazo mssica, como mostrado anteriormente decorre do
aumento na velocidade, bem como, o trabalho especfico, uma vez que o
ventilador uma mquina geradora que tem como funo transferir energia aofluido (FIGURA 14).
7/27/2019 PRONTO- Ventilador axial - Relatrio I
21/24
FIGURA 15. Diagrama potncia ativa versus vazo mssica.
FIGURA 16. Diagrama potncia do escoamento versus vazo mssica.
As potncias ativa e do escoamento tendem a aumentar com o aumento
da vazo mssica, como pode ser visualizado nas Figuras 15 e 16, uma vez
que para aumentar a vazo mssica necessrio o aumento de trabalho
cedido ao rotor (potncia ativa), logo o mesmo acontece com a potncia do
escoamento que esta relacionada ao fluxo de massa.
7/27/2019 PRONTO- Ventilador axial - Relatrio I
22/24
FIGURA 17. Diagrama de eficincia versus vazo mssica.
Valor da eficincia no condiz com a realidade, uma vez que uma
mquina real no pode ter eficincia maior ou igual a 100% (segunda lei da
termodinmica). A Figura 17 representa o diagrama de eficincia versus a
vazo mssica, onde pode ser visualizado erros sistemticos do experimento.
Erro este devido ao experimento no atender aos requisitos de escoamento
ideal. A aferio da velocidade de descarga do tnel de vento foi aferida em umponto na sada do tnel de vento, e um ponto no representa a velocidade real
do escoamento.
FIGURA 18. Diagrama de coeficiente de vazo versus coeficiente de presso.
7/27/2019 PRONTO- Ventilador axial - Relatrio I
23/24
Valor do coeficiente de vazo e de presso ajustado por um polinmio
de grau 2, com ajuste igual a 1, assim mostrando um comportamento descrito
pelo polinmio mostrado na FIGURA 18.
5. Concluses
A partir do experimento realizado foi possvel observar que diferentes
velocidades de rotao (crescentes) do ventilador axial (mquina de fluxo
geradora) proporcionam o aumento de grande parte das grandezas
caractersticas do escoamento, visto que o comportamento destas est ligado
as componentes (tangencial, absoluta e relativa) do tringulo de velocidades.
Para a eficincia da mquina de fluxo foram encontrados valores acima
de 100%, valores estes impossveis uma vez que conforme a segunda lei da
termodinmica nenhuma mquina real pode ter valor de eficincia igual a
100%. Discrepncia esta que pode ser explicado por erros de medio das
grandezas de velocidades no fim do tnel, uma vez que foi medido apenas um
nico ponto, e este no descreve o valor de velocidade real do escoamento,
no o caracterizando, sendo assim no sendo possvel encontrar o valor real
da potncia do escoamento.
6. Referncias Bibliogrficas
ANDRADE, Eduardo Santos; LEAL da SILVA, Robson. Clculo da
eficincio energtica em ventiladores de mesa com diferentes anemmetros e
metodologias. Enepe, Dourados, n. , p.1-17, 2012.
Alex Maurcio Arajo. Ventilao aplicada a engenharia de segurana do
trabalho. Disponvel em:
Acesso em: 5 de dezembro de 2012.
BRASIL. Inmetro. ANEXO A - METODOLOGIA DE ENSAIO PARA
DETERMINAO DA EFICIENCIA ENERGTICA. Ministrio Do
Desenvolvimento, Indstria E Comrcio Exterior, p.28-42, 23 mar. 2011. 22.
7/27/2019 PRONTO- Ventilador axial - Relatrio I
24/24
FOX et al. Introduo a mecnica dos fluidos. 7. ed. Rio de Janeiro: Ltc,
2010.
INCROPERA, F.p. et al. Fundamentos de tranferncia de calor e de
massa. 6. ed. Rio de Janeiro: Ltc, 2011. 643 p.
Ivano Alessandro Devilla, M.S.Ventiladores. Disponvel em: . Acesso em: 3 de dezembro de 2012.
SILVA, Robson Leal da; ANDRADE, Eduardo Santos. Eficincia
energtica e potncia de escoamento proporcionado por um ventilador axial de
pequeno porte para uso residencial. Conem, So Luis, n. , p.1-10, 2012.
Toginho Filho, D. O., Andrello, A.C., Catlogo de Experimentos do
Laboratrio Integrado de Fsica Geral Departamento de Fsica. Universidade
Estadual de Londrina, Maro de 2009.
Philip J. Pritchard, John C. Leylegian. Introduction to fluid mechanics.
United States, 2011. P. 493-494.
Ventiladores. Disponvel em:
Acesso em: 3 de dezembro de
2012.
Ventiladores. Disponvel em: . Acesso em: 5
de dezembro de 2012.