Commercial Boiler Controls and Accessories
Your Total Source For Mechanical Room Packages
2
The Hydronic Boiler Control Solution
T
P
V
P P P
T
T
T
T
DHWLoop
HeaderTemp
BoilerMix
Loop
BoilerInlet
Outlet
OutdoorTemp
Stack
Alarm
Fan
Ignitor
Pilot Valve
Main Valve(s)
L2
L1
Flame Signal
Interlock
PII
Limit Input(s)
Limit Annunciation (8)
Remote Reset
TOD
STAT
BuildingAutomation
System
SystemOperatorInterface
LocalKeyboardDisplayModule
Boiler
DomesticHot
WaterTank
T
CentralCooling
Loop
V
V
Key
Valve Output
Pump Output
Temperature Input
Output
Input
24 Vac
T
2
3
SOLA Hydronic ControlThe Only Control You Need•10 Integrated Control Functions
> Primary flame safeguard control
> Igniter / spark generator
> Pump control
> Outdoor reset control
> High limit control: Boiler outlet
> High limit control: Domestic hot water
> Operating control: Central heating
> Operating control: Domestic hot water
> PID load control: Central heating
> PID load control: Domestic hot water
•Reduce Installation, Wiring Time, Cabinet Space
> Replaces multiple devices with a single integrated compact device
> Optional program module enables back-up and cloning features
•Algorithm Prioritization
> Burner demand: Central heating, domestic hot water and frost protection
> Firing rate limiting: Anti-condensate, stack, boiler delta-T, boiler slow start, boiler outlet
•Expanded Diagnostics
> 11-item programmable first-out annunciation
> 15-item lockout condition history and 15-item alert condition history
•Flexible
> User selectable parameters, features and program settings to meet individual requirements
> Boiler network can grow to meet future demands
•Safety/Boiler Protection
> Frost protection, slow start, anti-condensate, boiler delta-T, stack high limit, domestic hot water high limit, outlet T-rise limit
•Affordable
> Compare to purchasing, installing and maintaining 10 individual controls
•Future Provisions
> Multiple boiler lead-lag
> Thermostat input
> Fuel air ratio control for full modulation power burners
The Integrated Burner/Boiler Management SolutionTen Controls In One
Complete Boiler Room Peripheral Packages
Expansion Control
Boiler Sequencing
Control
Pressure & Backflow Control
Air Elimination
Pump Speed Control
Mixing Control
Flame Safeguard Control & Fuel Air Systems
Complete Domestic Water Peripheral Packages
* For illustration purposes only, not a typical system
COLD
Mixed
Boiler Sequencing
Control
Expansion Control Domestic Water Heating System
Mixing Systems
Air Elimination
4
5
A Component Approach to Burner/Boiler ManagementComponent Boiler Controls
T775 Electronic Standalone ControllerOne controller with many features self-containedIf your application does not require an integrated approach, Honeywell also offers a component based solution. The T775 electronic standalone controller along with the RM7800 series burner controls or Control Links can be used to provide boiler control. Choose from the standard, modulating, reset, boiler, sequencer, and universal models to meet your application needs.
•T775 Integrated Control Functions
> Pump Control > Outdoor Reset Control > Operating Control: Central Heating > PID Load Control: Central Heating > Compatible with the RM7800 Series Burner Controls and Control Links ML7999 > T775 has UL873, it is not intended to meet the requirements of UL353.
•Easy-To-Use Graphical Interface
> Easy-to-use, intuitive programming will save you time on every job
• Internal Time Clock Scheduler
> Save energy during unoccupied times using the Setback and Disable Output options without buying an additional time clock
•Up To Two Independent Modulating Outputs
> Each output can be individually configured for 0-10 Vdc, 2-10 Vdc, 4-20 mA or Series 90
•Optional Configurable Integral And Derivative Times
> Standard on every device, this feature delivers pinpoint control. Now you can adjust reaction times and behavior, giving you more control
•Reset Models With Simplified Setup
> Simply enter the high and low control temperatures and the corresponding high and low outdoor temperatures, and you’re done
> As your outside temperature gets colder, the setpoint temperature automatically adjusts to save energy
•Universal Model To Control Pressure
> Easy setup for configuring control of pressure with a 0-10 Vdc or 4-20 mA input
> Pressure can be displayed in psi, Pa, kPa or in. w.c.
> Outputs include two modulating and two relay outputs that can each have their own setpoint
•Special Boiler Model
> With a single control you can handle multiple on/off low mass boiler applications > Features include dedicated pump output, staging for up to 12 relays, digital output alarm,
pump exercise, pre/post pump purge, warm weather shut down and lead/ lag sequencing
For more information, see http://customer.honeywell.com/T775
6
A Component Approach to Burner/Boiler ManagementComponent Burner Controls
Flame DetectorsFlame Detectors to Fit Every Application•UltraViolet,TraditionalUVTubeandSolidState
> Minipeeper
> Dynamic Self-Check (mechanical shutter)
> Adjustable Sensitivity
•Infrared
•VisibleLight
•FlameRod
•NEMA1,4,and7EnclosuresplusExplosionProofEnclosures
•Forsingleordualfuelapplications
7800 SERIES Burner ControlsReliable. Safe. Flexible.•Integratedburnercontrolforsingleburnerapplications
•Functionsincludeburnersequencing,flamesupervision,systemstatusindication,systemdiagnostics and troubleshooting
•Widerangeofapplicationsincludingburners,boilers,furnaces,rooftopunits,kilns and ovens
•Offersintelligentcontrolanywayyouwantit
•Canbecustomizedwiththefollowingoptionalcomponents:
> Valve Proving System (VPS)
> Keyboard Display Module
> Communication: Modbus™ RTU
> Configurable First-Out Expanded Annunciator
•DynamicSelfChecksandTrouble-FreeRetrofit
7
S7999B System DisplayCommission. Configure. Monitor. Control•CommissionControLinksfuelairratiocontrol
•ConfigureHoneywellModbusnetwork
> S7830 Expanded Annunciator terminal names
> Modbus network burner/boiler nodes and names
•Monitordevicestatus,faultcodehistory,diagnosticinformation
> 7800 SERIES or R7140 Burner Controls
> ControLinks Fuel Air Ratio Control
> S7830 Expanded Annunciator
> UDC2500/3200/3500 Universal Digital Controllers with Modbus
•ControlremoteresetoftheburnerandUDCcontrols
•Modbusnetworkofupto99devicesornodeswithS7810MModbusmodule
A Component Approach to Burner/Boiler ManagementComponent Burner Controls
ControLinks™
The Linkageless Advantage•LinkagelessFuelAirRatioControlSystem
•StandAloneParallelPositioningControlSystemdesignedforEasyRetrofit
•IntegratedThermalShockProtectionAlgorithms
•MaximizeBurnerEfficiencyandEnergySavings
•Reducesfuelusagefrom2to6%andbeyond
•4ChannelOutputControl
> Combustion Air
> Fuel 1
> Fuel 2
> Flexible Usage
8
Variable Frequency DrivesComponent Based Boiler Control Solutions
NXS And NXL Families Of Variable Frequency DrivesFully configurable bypass options available•Commonuserinterface–Programoneandyoucanprogramthemall
•Built-inACchoke(inputlinereactor)reduceelectromagneticandharmfulharmonicinterference
•AModularConstructionandwideselectionofoptioncardsmaketheNXseriesadrivethat can be easily incorporated into almost any application
•VFDsofferasignificantopportunityforenergysavingsincommercialsbuildings; forexample,reducingfanspeedby50%resultsin87.5%energysavings
•Built-inapplicationsmakeanysetup,fromacceptingabasicspeedsignaluptocomplexPIDcontrol,quickandeasy;enterthemotornameplateinformationandtheNXdoestherest.
•Broadcommunicationscapabilities(BACnet®, LONWORKS®, Modbus®, N2 and other protocols)
•Theon-boardintelligencemeansthedrivecanreplacethelocalcontroller
•VersatilePCtoolsforloading,commissioning,andmonitoring
•Warranty—3yearsfrominstallation
9
Variable Frequency DrivesComponent Based Boiler Control Solutions
DS06 Series DialSet® Pressure Regulating ValveControl water pressure without a gauge•Built-inadjustmentdialeliminatestheneedforagaugewhenadjustingthestatic
pressure setting
•Theinternalandexternalthreadingallowsforuseinthread-by-threadsingle-union or double-union configurations
•Noncorrodingunitizedcartridgecontainsalltheworkingpartsandiseasilyreplaceable
•ASSEandIAMPOcertified
•Flexibilitytoworkinavarietyofapplicationsreducinginventory
•OutletPressureAdjustmentrangesaresuitableforhousehold,lightcommercial,industrialand turf-and-irrigation applications
•Outletpressurerange-1½"to2"-15psito130psiwithainletpressure
•Inletpressureof400psi
HL Series™ High-Low Temperature Control SystemsThe ultimate solution for controlling hot water temperatures caused by unpredictable demand•HLSeries™ High-Low Systems are pre-engineered, assembled and tested
•Increasedsafety:controlsexternalhotwatertemperatureduringfluctuatingdemandperiods;allowshighertanktemperaturestokillbacteria
•Easilyinstalledintoexistingplumbingconfigurations;completesystemonlyneedstobehooked up by installer, not an engineer
•Unique—specialtoolsforeaseofsetupandmonitoringincludeDialSet® Pressure Regulating Valve and Digital Temperature Gauge
•Systemtemperaturevariationsminimized—usingHighandLowCapacityThermostaticMixingValvesmaintainswatertemperatureduringanydemand;lowflowreduction if cold or hot water supply is interrupted
•ASSE1017rated
Pressure/Demand ControlsComponent Based Boiler Control Solutions
10
Gas ValvesWide Range Of Products To Meet Every Need
Fluid Power Gas Valves and ActuatorsProvides high level of safety and application flexibility•Usedtocontrolflowofgastocommercialandindustrialburners
•Ratedassafetyshutoffvalves
•HighClose-offpressure
•On-Off,Off-Lo-HiandModulatingmodels
•Variousvoltagemodelsavailable
Diaphragm ValvesValve and actuator in a single body construction•Solenoidoperatedvalvesforuseonboilers,unitheaters,ductfurnaces,makeupairand
rooftop heaters
•DifferentversionsavailablefornaturalgasandLP(liquifiedpetroleum)
•On-OffandRegulatingmodels
•120Vor24Vavailable
•RapidOpeningorSlowOpening
•Internalventing
Solenoid ValvesFast opening and closing safety shut-off valves•Usedinwidevarietyofapplicationsincludingfurnacesandovens,commercialwater
heaters, power burners, and boilers
•Normallyclosedvalveofferssafetyshutoffwithfastopen,fastcloseoperation
•Normallyopenvalvefunctionsasaventvalvefordoubleblockandbleedsystems
•Usedwithnaturalgas,manufacturedgas,orLP
•120Vor24V
•2psiversion3/8"-3"
•5psiversion3/8"-2"
11
Pressure ControllersFor Operating Controls Or Safety Limits On Fuel, Air, And Steam Pressure Systems
C6097 Gas/Air Pressure SwitchCompact, easy connections…improved reliability•FlangemountorNPTMount
•Models
> C6097A-SPDT Break Make on Fall
> C6097B-SPDT Break Make on Rise
•ScaleRange:0.4"-60"WC
1.5"to7"PSI
•Optionsofmanualresetorautorecycle
•Compactdesign
Servo Regulated Combination Gas Valves and VenturisOptimizeefficiency…reduceemissions•Costeffectivemodulatingfuel/aircontrolforpremixburnerapplications
•Modulating1:1Fuel/AirRatioControl
•Internaldoubleblocksafetyshut-offvalves
•Commercial24Vacand120Vacvalvemodels
•Premixesgasandairinproperproportionstoensuresafe,reliable,efficientcombustion
•ReducesNOx,CO,andCO2 emissions
•Easytomixandmatchcomponents
PressureTrol® ControllersReliable Pressure Control•Providesoperatingcontrolwithautomaticlimitprotectionforpressuresystemsupto
300 psi, or oil burner systems up to 150 psi
•Canbeusedwithsteam,air,non-combustiblegases,orfluidsnon-corrosivetothepressure sensing element
•MICROSWITCH® snap-acting switches
•Automaticandmanualresetmodelsavailable
•ScaleplatesmarkedinMetric(kg/cm2)andEnglish(psi)units
12
Air Eliminators And Air VentsEffectively Eliminates Air, Noise And Callbacks
PV Series SuperVent®
Effectively eliminates air and noise from hydronic heating systems•Debrisbaffletocontroldirtfoulingandpreventfailure
•NPTandsweatconnectionsavailableinthreaded,flangedandflangedcleanableforapplication flexibility
•Operatingtemp:250°FMax
•No-clogventendsleakingandcallbacks
•Adjustableventtopcollarringallowseasierinstallationandapplicationflexibility
•Flowratesupto940GPM
•Workingpressure:150psimaximum
SV Series SuperVent Top Air VentLeak-resistant, long-term performance•Durablebrassbodywithnoferrousmetals
•No-clogVent,includesshut-offcap
•Debrisbaffletocontroldirtfoulingandpreventsfailure
•Hightemperaturethermoplasticfloatcontrolsventingrateundercontinuousoperation
•Includesservicecheckvalveforeasymaintenancewithoutdrainingsystem
•3/8"NPT(SV173model)&½"NPT(SV175model)connectionsizes
EA79 Automatic Air VentIndustrial Series Automatic Air Vent for high pressure•Industrialgradeairvent
•RuggedBrassbodyconstruction
•Built-inshut-offvalveforeasyservicewithdrainingsystem
•¾"NPTexternalthreadsand½"femaleNPTthreads
•Replaceablefloattopassembly
13
AM-1 1070 Series Thermostatic Mixing ValveDesigned to meet new ASSE 1070 plumbing code for point-of-use applications•Lockablehandwheelpreventstamperingforcodecompliance
•Cvratingof1.8provideslargerflow
•Tefloncoatingresistsmineraldepositbuilduptoextendlife
•ASSE1070listed
•IncludesThermostripforinitialtemperaturesetting
UMV Series — Universal UnderSink Thermostatic Mixing ValveThe smart way to help prevent accidental scalding•Builtforeasyinstallationinboth3-and
4- port applications
•Providesprotectionrightatthesink
•Largeadjustmentknobwithtamper-resistentscrewtolockinsettingforaddedsafety
•InternalCheckValvesinhotandcoldinletspreventcrossflow
•Newblacklockablehand-wheelpreventstampering
MX Series™ Large Flow Proportional Mixing ValveHigh capacity mixing valve is specifically designed for larger applications•Valvecontrolshotandcoldsupplybasedoncontrolsetting
•Teflon® coating increases product life and reduces callbacks
•Tamper-evidenttemperatureadjustment
•UnionNPTandflangedmodels
•ASSE1017listed(UnionModelsonly)
Thermostatic Mixing ValvesDesigned To Protect People And Equipment
14
TAX Series Commercial ASME ModelsCommercialHorizontalmodelswithoutsaddlesASME125PSIG•7.8–132gallons
•Diaphragmdesignandconstructionper ASME standards
•Horizontalandverticalmodeloptions
•Maximumworkingpressure–100psi
•Maximumoperatingtemperature–240°F
Commercial Expansion TanksMaintains System Pressure And Customer Relationships
XPS Series Commercial Heating Non- ASME Models For use with closed hydronic heating & cooling•14–86gallons
•Factorypre-chargedto12psi
•Stainlesssteelsystemconnection
•Maximumworkingpressure–100psi
•Maximumoperatingtemperature–240°F
TAXV Series Commercial ASME ModelsCommercialVerticalmodels–ASME125PSIG•7.8–132gallons
•SteelShell–HeavyDutyDiaphragm
•Maxoperatingpressure125psi
•Maxoperatingtemperature240F
•ASMEConstruction
15
TX Series Thermal Expansion TanksForusewithdomestichotwatersystems–largecapacity•158–586gallons
•100%non-metallic,polypropylenelinerandnon-corrosivewaterreservoir
•Controlspressurebuildupinsystem
•Preventswaterhammer
•Eliminatesreliefvalvespillage
•Helpsextendwaterheaterlife
TL Series Commercial ASME ModelsCommercial usage for large closed heating systems•53–528gallons
•Replaceablediaphragmdesignwith floor stand
•ConstructionperASMEstandards
•Maximumworkingpressure–100psi
•Maximumoperatingtemperature–240°F
Automation and Control Solutions
In the US:
Honeywell
1985 Douglas Drive North
Golden Valley, MN 55422-3992
In Canada:
Honeywell Limited
35 Dynamic Drive
Toronto, Ontario M1V 4Z9
customer.honeywell.com