P RO F I BUS PROCESS FIELD BUS ® I T I P M Operate IT Engineer IT Control IT Field IT PROFIBUS DP/DPV1 Ethernet F Remote I/O M PID M Data Sheet 10/630.47 EN Industrial Devices overview PROFIBUS DP IT Field IT – Flowmeter Field IT – Electrical Actuator Field IT – Redundancy Link Module Inform IT – Process Recorder Analyze IT – Analyzer Power IT – Power Transducer Protect IT – MNS Motor Management INSUM Drive IT – Frequency Converter Drive IT – DC Drives Control IT – Process Controller Control IT – Motor Management, Motor Starter Control IT – Remote I/O and I/O System Control IT – Distributed Automation

Profibus DP ABB Certified Equipments Overview En

  • Upload
    ykuscu

  • View
    231

  • Download
    3

Embed Size (px)

Citation preview

Page 1: Profibus DP ABB Certified Equipments Overview En

Data Sheet10/63�0.47 EN

■ FieldIT – Flowmeter

■ FieldIT – Electrical Actuator

■ FieldIT – Redundancy Link M

■ InformIT – Process Recorde

■ AnalyzeIT – Analyzer

■ PowerIT – Power Transduce

■ ProtectIT – MNS Motor Man

■ DriveIT – Frequency Conver

■ DriveIT – DC Drives

■ ControlIT – Process Control

■ ControlIT – Motor Managem

■ ControlIT – Remote I/O and

■ ControlIT – Distributed Auto

Industrial

Devices overviewPROFIBUS DP

IT

P R O F I

B U S

PROCESS FIELD BUS

®

IT

IP

M

OperateIT

EngineerIT

ControlIT

FieldIT

PROFIBUS DP/DPV1

Ethernet

F

RemoteI/O

M

PID

M

odule

r

r

agement INSUM

ter

ler

ent, Motor Starter

I/O System

mation

Page 2: Profibus DP ABB Certified Equipments Overview En

2

Devices overview 10/63�0.47 ENPROFIBUS DP

FieldIT Flowmeter

FXM2000-DM. (COPA/MAG-XM) FXE4000 (COPA/MAG�XE) FXM2000-DC. (COPA/MAG�CM)Data Sheet D184S031U02 D184S044U02 D184S007U02

Internet www.abb.com/instrumentation www.abb.com/instrumentation www.abb.com/instrumentationIndustrialIT enabled – – –

Application Electromagnetic Flowmeter.Suitable for universal use. Available in compact or split architecture.

Accuracy:0.4 % (optionally 0.2 %) of rateMeter size: DN 3...2400 (flange)DN 1...100 (variable connections)

Electromagnetic Flowmeter.Affordable standard instrument in flanged and adapter�flanged versions.Option: Stainless steel with variable process connections.

Precision: ≤ ± 0.5 % of rateRange:DN 3...1000 (flanged)DN 3...100 (adapter�flanged)

Electromagnetic Flowmeter.With capacitive electrodes,used with measured mediumswith insulating deposits and low conductivity > 0.05 µs/cm.

Accuracy:1 % of rateMeter size:DN 25...300 (flange)

Ambient temperature �25...+60 °C �25...+60 °C �25...+60 °CType of protection IP 67 (IP 68) IP 67 (IP 68) IP 67 (IP 68)Explosion protection – – –Registration CE 3A, EHEDG, CE CE

Physics RS 485 RS 485 RS 485Protocol PROFIBUS DP PROFIBUS DP PROFIBUS DPMax. Baud Rate ≤ 1.5 Mbit/s ≤ 1.5 Mbit/s ≤ 1.5 Mbit/sIdent. No. 6666 HEX 6666 HEX 6666 HEXPNO Certificate No. – – –Bus adress

local adjustmentcentral adjustment

0...126 (default 126)Keypad

Software (e.g.: PLC)

0...126 (default 126)Keypad

Software (e.g.: PLC)

0...126 (default 126)Keypad

Software (e.g.: PLC)Data length cyclical

readwrite

fix 16 Bytefix 16 Byte

fix 16 Bytefix 16 Byte

fix 16 Bytefix 16 Byte

Profil – – –Transducer Block – – –Function Block(only for profil�conforming devices)

DP device only:rate, status, counter

DP device only:rate, status, counter

DP device only:rate, status, counter

Device configurationcentral adjustment

local adustment

Software (e.g.: PLC)

Keypad and display

Software (e.g.: PLC)

Keypad and display

Software (e.g.: PLC)

Keypad and display

External supply Yes Yes Yes

Page 3: Profibus DP ABB Certified Equipments Overview En

3

Devices overview 10/63�0.47 ENPROFIBUS DP

FieldIT Flowmeter

FSM1000 FMC2000-MM2 (TRU�MASS) FMC2000-MM2 (TRIO�MASS)

Data Sheet D184S034U02 D184S020U02 D184S068U02

Internet www.abb.com/instrumentation www.abb.com/instrumentation www.abb.com/instrumentationIndustrialIT enabled – – –

Application Electromagnetic Flowmeter.Especially suitable for fast response times, liquids with higher concentration of hard solid particles, two�phase fluids.

Accuracy:1 % of rateMeter size: DN 3...1000 (flange)DN 1...100 (variable connections)

Coriolis Mass Flowmeter.Simultaneous determination of mass, density and temperature; single�tube�design, self�emptying, space�saving, robust, inexpensive.

Temperature of fluid: �50...+180 °CAccuracy:Flow: 0.25 % of rate Density: 5 g/l, 1 g/lMeter size: DN 10, DN 15, DN 20,DN 25, DN 40, DN 50

Coriolis Mass Flowmeter.Simultaneous determination of mass, density and temperature;parallel�tube�design, self�emptying, space�saving, robust, inexpensive.

Temperature of fluid: �50...+180 °CAccuracy:Flow: 0.15 %, 0.25 %, 0.4 % of rateDensity: 5 g/l, 1 g/lMeter size: DN 10...DN 150 (½“...6“)

Ambient temperature �25...+60 °C �20...+60 °C �20...+60 °CType of protection IP 67 (IP 68) IP 67 IP 67Explosion protection – – –Registration CE CE 3A, CE

Physics RS 485 RS 485 RS 485Protocol PROFIBUS DP PROFIBUS DP PROFIBUS DPMax. Baud Rate ≤ 1.5 Mbit/s ≤ 1.5 Mbit/s ≤ 1.5 Mbit/sIdent. No. 6666 HEX 6666 HEX 6666 HEXPNO Certificate No. – – –Bus adress

local adjustmentcentral adjustment

0...126 (default 126)Keypad

Software (e.g.: PLC)

0...126 (default 126)Keypad

Software (e.g.: PLC)

0...126 (default 126)Keypad

Software (e.g.: PLC)Data length cyclical

readwrite

fix 16 Bytefix 16 Byte

fix 16 Bytefix 16 Byte

fix 16 Bytefix 16 Byte

Profil – – –Transducer Block – – –Function Block(only for profil�conforming devices)

DP device only:rate, status, counter

DP device only:rate, status, counter

DP device only:rate, status, counter

Device configurationcentral adjustment

local adustment

Software (e.g.: PLC)

Keypad and display

Software (e.g.: PLC)

Keypad and display

Software (e.g.: PLC)

Keypad and display

External supply Yes Yes Yes

Page 4: Profibus DP ABB Certified Equipments Overview En

Devices overview 10/63�0.47 ENPROFIBUS DP

FieldIT, AnalyzeIT Flowmeter Analyzer Process Controller

FMT500-IG (Sensyflow iG) Advance Optima + PKV30-DPS D100 (Digitric 100)Data Sheet 10/14�6.41 EN 10/24�1.10 EN 10/61�6.11 EN

Internet www.abb.com/instrumentation www.abb.com/analytical www.abb.com/controlIndustrialIT enabled Yes – Yes

Application Thermal mass flowmeter for airand gases, determination of mass flow / standard volume flow and gas temperature.

Turn down ratio: 1:150Temperature of fluid:�25...+300 °CAccuracy:0.9% of reading + 0.05 % fs Meter size: DN 25...3000 mm (1"...120")

Modular product line for process analytics and emission monitoring.Offers a range of different analytical principles: NDIR, IR UV, thermal conductivity, O2 (paramagnetic) and flame ionization measurement of Hydrocarbons (FID).

Industrial Controller,1channel (1 PID algorithms). Multi�functional, flexible I/O configuration, extensive function library with preconfigured control strategies.

Frontal dimensions:96 mm x 96 mm

Ambient temperature �25...+50 °C �20...+50 °C (45 °C Uras) 0...50 °CType of protection IP 67 IP 20 / IP 54 Front.: IP 65; hous.: IP 30; term.: IP 20Explosion protection II 2(1) G EEx de [ia] ib II C T3; II 2 D EEx – –Registration CE, ATEX, FM, CSA CE, TÜV CE

Physics RS 485 RS 485 RS 485Protocol PROFIBUS DPV1 PROFIBUS DP PROFIBUS DPV1Max. Baud Rate ≤ 1.5 Mbit/s ≤ 12 Mbit/s ≤ 1.5 Mbit/sIdent. No. 05CA HEX 7503 HEX 9651 HEXPNO Certificate No. be applied – Z00413Bus adress

local adjustmentcentral adjustment

0...126 (default 126)Keypad

Software (e.g.: SMART VISION)

0...99Switches

1...125 (default 1)Buttons, IBIS�R+ via TTL/RS 232/485

–Data length cyclical

readwrite

5...15 Byte0... 9 Byte

up to 244 Byteup to 244 Byte

0...224 Byte0... 64 Byte

Profil V3.0 – –Transducer Block Flow – –Function Block(only for profil�conforming devices)

2 AI: flow, gas temperature1 TOT, SET-, SET/MOD-TOT:flow totalizer1 Character Input: characteristic curce, PRESET�TOT value

Physical values,analog/digitale I/O'sStatus signals: error, maintenance request, maintenance mode

Analog IN: process value, inputsAnalog OUT: set points, outs,analog outputsDigital IN/OUT: modes,digital I/O and many more

Device configurationcentral adjustment

local adustment

DTM(for FDT V1.2)

Keypad and display

Full remote control with EthernetTCP/IP and HMI software

Keypad and display

Keypad and display orIBIS�R+ via TTL/RS 232/485

External supply Yes Yes Yes

4

Page 5: Profibus DP ABB Certified Equipments Overview En

Devices overview 10/63�0.47 ENPROFIBUS DP

ControlIT Process Controller

D500 (Digitric 500) P100 (Protronic 100) P500, P550 (Protronic 500/550)Data Sheet 10/61�6.15 EN 10/62�6.11 EN 10/62�6.15 EN

Internet www.abb.com/control www.abb.com/control www.abb.com/controlIndustrialIT enabled Yes Yes Yes

Application Industrial Controller with PLC functions, 1...4 channel (4 PID algorithms). Multi�functional, flexible I/O configuration, preconfigured and user�configurable control strategies including PLC functions.

Frontal dimensions:96 mm x 96 mm

Process Controller,1 channel (2 PID algorithms).Multi�functional, extensive library of functions with preconfigured control strategies, wide range of applications.

Frontal dimensions:72 mm x 144 mm

Process Controller with PLC functions, 1...4 channel (4 PID algorithms). Multi�functional, flexible I/O configuration, preconfigured and user�configurable control strategies including PLC functions.

Frontal dimensions:72 mm x 144 mm

Ambient temperature 0...50 °C 0...50 °C 0...50 °CType of protection Front.: IP 65; hous.: IP 30; term.: IP 20 Front.: IP 65; hous.: IP 30; term.: IP 20 Front.: IP 65; hous.: IP 30; term.: IP 20Explosion protection – – –Registration CE CE CE, VdTÜV water level, DIN 3440

Physics RS 485 RS 485 RS 485Protocol PROFIBUS DPV1 PROFIBUS DPV1 PROFIBUS DPV1Max. Baud Rate ≤ 1.5 Mbit/s ≤ 1.5 Mbit/s ≤ 1.5 Mbit/sIdent. No. 9651 HEX 9651 HEX 9651 HEXPNO Certificate No. Z00413 Z00413 Z00413Bus adress

local adjustmentcentral adjustment

1...125 (default 1)Keypad, IBIS�R+ via TTL/RS 232/485

1...125 (default 1)Keypad, IBIS�R+ via TTL/RS 232/485

1...125 (default 1)Keypad, IBIS�R+ via TTL/RS 232/485

–Data length cyclical

readwrite

0...224 Byte0... 64 Byte

0...224 Byte0... 64 Byte

0...224 Byte0... 64 Byte

Profil – – –Transducer Block – – –Function Block(only for profil�conforming devices)

Analog IN: process value, inputsAnalog OUT: set points, outs,analog ouputsDigital IN/OUT: modes, digital I/Oand many more

Analog IN: process value, inputsAnalog OUT: set points, outs,analog ouputsDigital IN/OUT: modes, digital I/Oand many more

Analog IN: process value, inputsAnalog OUT: set points, outs,analog ouputsDigital IN/OUT: modes, digital I/Oand many more

Device configurationcentral adjustment

local adustment

Keypad and display orIBIS�R+ via TTL/RS 232/485

Keypad and display orIBIS�R+ via TTL/RS 232/485

Keypad and display orIBIS�R+ via TTL/RS 232/485

External supply Yes Yes Yes

5

Page 6: Profibus DP ABB Certified Equipments Overview En

Devices overview 10/63�0.47 ENPROFIBUS DP

InformIT Process Recorder

PM100 (PointMaster 100) PM200 (PointMaster 200) LM200 (LineMaster 200)Data Sheet 10/41�1.10 EN 10/41�2.10 EN 10/43�2.10 EN

Internet www.abb.com www.abb.com www.abb.comIndustrialIT enabled Yes Yes Yes

Application 6 channel Multipoint Recorder.Measurement and registration of process signals, event marks, limit value monitoring, alarm relays.Data readout from PROFIBUS master.

Frontal dimensions:144 mm x 144 mm

6 channel Multipoint Recorderwith text printing facility.Measurement and registration of process signals, event marks, limit value monitoring, alarm relays, accounting functions, mathematical functions. Data readout/write in from PROFIBUS master. Text writingfrom PROFIBUS master.

Frontal dimensions:144 mm x 144 mm

4 channel Continuous�line Recorder.Measurement and registration of process signals, text printing facility(option), event marks, limit value monitoring, alarm relays, data readout from PROFIBUS master, text writing from PROFIBUS master.

Frontal dimensions:144 mm x 144 mm

Ambient temperature 0...50 °C 0...50 °C 0...50 °CType of protection Front: IP 54; rear: IP 20 Front: IP 54; rear: IP 20 Front: IP 54; rear: IP 20Explosion protection – – –Registration FM, CSA, UL, GOST, CE FM, CSA, UL, GOST, CE FM, CSA, UL, GOST, CE

PhysicsProtocolMax. Baud RateIdent. No.PNO Certificate No.Bus adress

local adjustmentcentral adjustment

via gateway BusCon via gateway BusCon via gateway BusCon

Data length cyclicalreadwrite

ProfilTransducer BlockFunction Block(only for profil�conforming devices)

Read: measurement channel 1...6,status of the limits

Read: measurement channel 1...6,status of the limitsWrite: analog value channel 1...6,free text up to 32 characters

Read: measurement channel 1...4,status of the limits, binary inputWrite: free text up to 16 characters

Device configurationcentral adjustment

local adustment

Keypad or SoftwareParapoint 100 via RS 485

Keypad or SoftwareParapoint 200 via RS 485

Keypad or SoftwareParaline 200 via RS 485

External supply Yes Yes Yes

6

Page 7: Profibus DP ABB Certified Equipments Overview En

Devices overview 10/63�0.47 ENPROFIBUS DP

PowerIT, FieldIT Power Transducer Gateway

ESU (Contrans E SU) BusConData Sheet 10/28�2.54 EN 10/49�7.20 EN

Internet www.abb.com www.abb.comIndustrialIT enabled Yes Yes

Application Universal Power Transducer.Measurement of all power current variables in single or three phase mains, mains synchronization and energy totalization.

PROFIBUS DP Gateway for Recorder and Power Transducer.Transmission of measured variables without delay, 1...15 Recorders/PowerTransducers connectable.

Ambient temperature �20...+60 °C 0...45 °CType of protection IP 40 (terminals IP 20) IP 20Explosion protection – –Registration CE CE

Physics RS 485Protocol PROFIBUS DPMax. Baud Rate ≤ 12 Mbit/sIdent. No. 2079 HEXPNO Certificate No. –Bus adress

local adjustmentcentral adjustment

via gateway BusCon0...126 (default 1)

Switch–

Data length cyclicalreadwrite

0...228 Byte0... 72 Byte

Profil –Transducer Block –Function Block(only for profil�conforming devices)

Read: all parameters in the network(U, I, P, Q, S, Phi, cos Phi, sin Phi, f), up to 4 energy totalizers

Device configurationcentral adjustment

local adustment

Software IBIS�E viaLCI adapter or RS 485

Switches

External supply Yes Yes

7

Page 8: Profibus DP ABB Certified Equipments Overview En

Devices overview 10/63�0.47 ENPROFIBUS DP

FieldIT, DriveIT Electrical Actuator Frequency Converter

Contrac ACS 160Data Sheet 10/68�1.51 EN, 10/68�2.73 EN, 10/68�

8.22 EN, 10/68�8.26 EN, 10/68�8.27 NE3BFE64383671 EN

Internet www.abb.com/instrumentation www.abb.com/motors&drivesIndustrialIT enabled Yes Yes

Application Intelligent electrical continuous Actuators for modulating control.Type: PME120, RHD..., LME620, RSD...Part turn drives from 100...16000 Nm;Linear drives from 4...200 kN;digital communication, µPC control.

Meter size:Continuous positioning, precise, long�lived

Frequency Converter.ACS 160 for universal applications, in book shape, configuration possible for constant and square�law load torques.

Power connection:3�phase 380...500 V, ± 10 %, 50/60 Hz, 0.55...2.2 kWMotor connection:0...250 Hz

Ambient temperature �30...+65 °C �10...+40 °C (50 °C)Type of protection IP 66 IP 65 / NEMA 4Explosion protection – –Registration CE UL, CSA, CE

Physics RS 485Protocol PROFIBUS DP via communication moduleMax. Baud Rate ≤ 1.5 Mbit/s CFB-PDPIdent. No. 9655 HEXPNO Certificate No. –Bus adress

local adjustmentcentral adjustment

2...126 (default 126)SMART VISION via RS 232

2...126 (default 2)Panel, Software DriveWindows Light

–Data length cyclical

readwrite

3...10 Bytefix 5 Byte

4...28 Byte4...28 Byte

Profil V2.0, Class A V2.0Transducer Block Electrical Actuator Adjustable DrivesFunction Block(only for profil�conforming devices)

1 AI: setpoint with status, position withstatus, digital position, standard andextended bit coded device information,signal ready for operation

Reference and actual value,speed, current, torque, frequency,fault signals, PPO1�PPO5 with parameter transfer

Device configurationcentral adjustment

local adustment

SMART VISION via RS 232

DTM in preparation

Panel or Software DriveWindows Light via RS 232

External supply Yes Yes

8

Page 9: Profibus DP ABB Certified Equipments Overview En

Devices overview 10/63�0.47 ENPROFIBUS DP

DriveIT Frequency Converter

ACS 400 ACS 600 ACS 800Data Sheet 3BFE64226703 EN 3BFE64162021 EN 3AFE64572504 EN

Internet www.abb.com/motors&drives www.abb.com/motors&drives www.abb.com/motors&drivesIndustrialIT enabled Yes Yes Yes

Application Frequency Converter.ACS 400 for universal applications, in book shape, configuration possible for constant and square�law load torques.

Power connection:3�phase 200...240 V, ± 10 %,2.2...22 kW3�phase 380...480 V, ± 10 %,2.2...37 kW

Frequency Converter.Applications: pumps and ventilators, centrifuges, mixers, winders, spinning machines, materials�handling technology, roller tables, packing machines.

Power connection:3�phase 380...690 V, 48...63 Hz2.2...3000 kWMotor connection:0...300 Hz

Frequency Converter.Applications: pumps and ventilators, centrifuges, mixers, winders, spinning machines, materials�handling technology, roller tables, packing machines.

Power connection:3�phase 380...500 V, 48...63 Hz1.1...3000 kWMotor connection:0...300 Hz

Ambient temperature 0...40 °C (50 °C) 0...40 °C (50 °C) �15...+40 °C (50 °C)Type of protection IP 21 / IP 54 IP 22/IP 54 or IP 22/IP 42/IP 45 IP 21/IP 55 or IP 21/IP 22/IP 42/IP 45Explosion protection – – –Registration UL, CSA, CE UL, CSA, CE UL, CSA, CE

PhysicsProtocol via communication module via communication module via communication moduleMax. Baud Rate NPBA-12 NPBA-12 NPBA-12 or RPBA-01Ident. No.PNO Certificate No.Bus adress

local adjustmentcentral adjustment

2...126 (default 2)Panel, Software DriveWindows Light

2...126 (default 2)Panel, Software DriveWindows

2...126 (default 2)Panel, Software DriveWindows

–Data length cyclical

readwrite

4...28 Byte4...28 Byte

4...28 Byte4...28 Byte

4...28 Byte4...28 Byte

Profil V2.0 V2.0 V2.0Transducer Block Adjustable Drives Adjustable Drives Adjustable DrivesFunction Block(only for profil�conforming devices)

Reference and actual value, speed,current, torque, frequency, fault signals, PPO1�PPO5 with parameter transfer

Reference and actual value, speed,current, torque, frequency, fault signals, PPO1�PPO5 with parameter transfer

Reference and actual value, speed,current, torque, frequency, fault signals, PPO1�PPO5 with parameter transfer

Device configurationcentral adjustment

local adustment

DTM in preparation

Panel or SoftwareDriveWindows Light via RS 232

DTM in preparation

Panel or Software DriveWindows via FOC

DTM in preparation

Panel or Software DriveWindows via FOC

External supply Yes Yes Yes

9

Page 10: Profibus DP ABB Certified Equipments Overview En

Devices overview 10/63�0.47 ENPROFIBUS DP

DriveIT DC-Drives

DCS 400 DCS 500 DCS 600Data Sheet 3ADW000095 EN/FR/ES/IT 3ADW000066 EN/FR/ES/IT 3ADW000072 EN/FR/ES/IT

Internet www.abb.com/dc www.abb.com/dc www.abb.com/dcIndustrialIT enabled Yes Yes Yes

Application DC DRIVE: optimal for machine�builders or replacement; compact, fast commissioning, easy installation via configuration macros, regenerative or non�regenerative.

Applications: extruder, mixer, wire drawing, ski lifts, etc.Power connection: 3�phase 230...500 V, 50...60 Hz,12...520 kW, 4...1000 A

DC DRIVE: for demanding applications; free function block programming, 2Q and 4Q, 12 pulse parallel up to 20,000 A.

Applications: extruder, mixer, printing machines, conveyor belts, cranes, test riggs, ski lifts, metals, marines, field excitation.Power connection:3�phase 220...1000 V ±10%, 45...65 Hz, 5.5...20,000 kW

DC Drive cabinets for complex multi�drive applications, 2Q und 4Q,12 pulses parallel/serial/sequential applications up to 20,000 A.

Applications: conveyor belts and cranes, test riggs, plant construction, metallurgy, field excitation.Power connection:3�phase 220...1200 V ±10 %,45...65 Hz, 5.5...20,000 kW

Ambient temperature 0...40 °C (55 °C) 0...40 °C (55 °C) 0...40 °C (55 °C)Type of protection IP 00 IP 00, Cabinet IP 21 IP 00, Cabinet IP 21Explosion protection – – –Registration cULus, CE, C�tick cULus, CSA, CE CSA, CE, (cULus)

PhysicsProtocol via communication module via communication module via communication moduleMax. Baud Rate NPBA-12 NPBA-12 NPBA-12Ident. No.PNO Certificate No.Bus adress

local adjustmentcentral adjustment

2...126 (default 2)Panel, Software DriveWindows Light

2...126 (default 2)Panel, Software CM�Tool

2...126 (default 2)Panel, Software DriveWindows

–Data length cyclical

readwrite

4...28 Byte4...28 Byte

4...28 Byte4...28 Byte

4...28 Byte4...28 Byte

Profil V2.0 V2.0 V2.0Transducer Block Adjustable Drives Adjustable Drives Adjustable DrivesFunction Block(only for profil�conforming devices)

Reference and actual value, speed, current, torque, power, fault signals, PPO1�PPO4 (PPO5) with parameter transfer

Reference and actual value, speed, current, torque, power, fault signals, PPO1�PPO4 (PPO5) with parameter transfer

Reference and actual value, speed, current, torque, power, fault signals, PPO1�PPO4 (PPO5) with parameter transfer

Device configurationcentral adjustment

local adustment

DTM in preparation

Panel or SoftwareDriveWindows Light via RS 232

DTM in preparation

Panel or Software CM�Tool via FOC

DTM in preparation

Panel or Software DriveWindows via FOC

External supply Yes Yes Yes

10

Page 11: Profibus DP ABB Certified Equipments Overview En

Devices overview 10/63�0.47 ENPROFIBUS DP

DriveIT Communication Module

NPBA-12 RPBA-01 CFB-PDPData Sheet 3BFE64341588 EN 3AFE64504215 EN 3BFE64383671 EN

Internet www.abb.com/motors&drives www.abb.com/motors&drives www.abb.com/motors&drivesIndustrialIT enabled Yes Yes Yes

Application PROFIBUS communication module PROFIBUS communication module PROFIBUS communication module

Ambient temperature +5...+40 °C (55 °C) �15...+40 °C (50 °C) +5...+50 °C (55 °C)Type of protection IP 20 IP 20 IP 20Explosion protection – – –Registration UL, CSA, CE UL, CSA, CE UL, CSA, CE

Physics RS 485 RS 485 RS 485Protocol PROFIBUS DPV1 PROFIBUS DP PROFIBUS DPMax. Baud Rate ≤ 12 Mbit/s ≤ 12 Mbit/s ≤ 12 Mbit/sIdent. No. 6012 HEX 0812 HEX 1612 HEXPNO Certificate No. – – –Bus adress

local adjustmentcentral adjustment

Data length cyclicalreadwrite

Profil seeTransducer Block ACS 400, ACS 600, ACS 800, see ACS 800 see ACS 160Function Block(only for profil�conforming devices)

DCS 400, DCS 500 oder DCS 600

Device configurationcentral adjustment

local adustment

External supply Yes – –

11

Page 12: Profibus DP ABB Certified Equipments Overview En

Devices overview 10/63�0.47 ENPROFIBUS DP

ProtectIT MNS Motor Management INSUM®

MCU1 MCU2 MMIData Sheet 1TGC901007B0201 1TGC901007B0201 1TGC901007B0201

Internet www.abb.com/mns www.abb.com/mns www.abb.com/mnsIndustrialIT enabled Yes Yes Yes

Application Motor Control Unit 1:controls, monitors and protects single and three phase motors in accordance with set parameters. MCU1 provides control for standard drive types with two contactor control and current based motor protection and 12 pre�defined digital inputs for field contacts.

Motor Control Unit 2: see MCU1. MCU2 additionally provides voltage based protection functions. MCU2 provides control for drive types with three contactor control and 15 pre�defined and 2 general purpose digital inputs for field contacts.

Man�Machine�Interface for INSUM.6�digit LCD�display:For a clear display of data from all128 connected field devices. Encoder wheel and funtion keys: Simple and clear menu�driven operation.

Ambient temperature �5...+55 °C �5...+55 °C �5...+70 °CType of protection IP 20 IP 20 IP 30Explosion protection PTB Ex 01�30061 PTB Ex 01�30061 –Registration CE, IEC 439�1, PTB CE, IEC 439�1, PTB CE, IEC 439�1

PhysicsProtocolMax. Baud RateIdent. No.PNO Certificate No.Bus adress

local adjustmentcentral adjustment

via INSUM®-Gateway

Data length cyclicalreadwrite

Profil – –Transducer Block – –Function Block(only for profil�conforming devices)

Measurement: current, temperatureOperating commands:Messages: time meter, status, service,warnings, errors, etc.

Measurement: current, voltage, power,cos�phi, temperatureOperating commands:Messages: time meter, status, service,warnings, errors, etc.

see MCU1 and MCU2

Device configurationcentral adjustment

local adustment

DTM in preparation

Via SoftwareOS on Ethernet TCP/IP

DTM in preparation

Via SoftwareOS on Ethernet TCP/IP

External supply Yes Yes Yes

PROFIBUS DP

LON 78 kBaud

LON 1.25 MBaud

Ethernet TCP/IP

12

Page 13: Profibus DP ABB Certified Equipments Overview En

Devices overview 10/63�0.47 ENPROFIBUS DP

ProtectIT MNS Motor Management INSUM®

Backplane, Double Router GatewayData Sheet 1TGC901007B0201 1TGC901007B0201

Internet www.abb.com/mns www.abb.com/mnsIndustrialIT enabled Yes Yes

Application The INSUM Communication Unit (ICU) is the switchgear communication hub for both internal and external communi�cation. Internally it allows four subnet connections via routers for 32 devices/ subnet. The ICU can provide three communication links for external communication. Besides this, the Local MMI and INSUM OS software are also directly connected to ICU.

Gateway serves for protocol conversion from LON (INSUM system)to PROFIBUS (DCS). The PROFIBUS Gateway can provide 24 binary bits of status information and current information to DCS.

Ambient temperature �5...+70 °C �5...+70 °CType of protection IP 30 IP 30Explosion protection – –Registration CE, IEC 439�1 CE, IEC 439�1

Physics RS 485Protocol PROFIBUS DPMax. Baud Rate fix 1.5 Mbit/sIdent. No. 067E HEX (Software Version 2.3)PNO Certificate No. –Bus adress

local adjustmentcentral adjustment

via INSUM®-Gateway 1...126 (default 126)MMI, Software OS

–Data length cyclical

readwrite

0...244 Byte0... 49 Byte

ProfilTransducer BlockFunction Block(only for profil�conforming devices)

see MCU1 and MCU2 see MCU1 and MCU2

Device configurationcentral adjustment

local adustment

External supply Yes Yes

13

Page 14: Profibus DP ABB Certified Equipments Overview En

Devices overview 10/63�0.47 ENPROFIBUS DP

ControlIT Motor Starter

MSD11-FBP MSR22-FBP MFI21-FBPData Sheet 2CDC133002D0202 2CDC133001D0202 2CDC131001D0202

Internet www.abb.com www.abb.com www.abb.comIndustrialIT enabled Yes Yes Yes

Application Motor Starter Direct:Complete unit mainly to connect three�phase a.c. motors to line, direct, for pumps, ventilators, centrifuges, mixers, winding machines, conveyors and others.

Line voltage:400 V AC, 50 and 60 cpsMotor current range:0.16...12 A

Motor Starter Reverse:Complete unit mainly to connect three�phase a.c. motors to line, reverse, for rotary�tables in handling and warehousing systems, lift devices and others.

Line voltage:400 V AC, 50 and 60 cpsMotor current range:0.16...12 A

Motor Starter Fieldbus Interface:Connection of manual motor starters MS325 and contactors to fieldbuses.Supports different switchgear assemblies such as reverse starter, star�delta starter, with dedicated logical functions and timers. Free digital inputs and outputs e.g. for sensors.

Motor current range:0.16...25 A (range of MS325)

Ambient temperature 0...55 °C 0...55 °C 0...55 °CType of protection IP 20 IP 20 IP 20Explosion protection – – –Registration CE, UL, CSA, GL, BV, LRS CE, UL, CSA, GL, BV, LRS CE, UL, CSA, GL, BV, LRS

PhysicsProtocolMax. Baud Rate via PROFIBUS Plug via PROFIBUS Plug via PROFIBUS PlugIdent. No. PDP22-FBP PDP22-FBP PDP22-FBPPNO Certificate No.Bus adress

local adjustmentcentral adjustment

2...99 (default 0)Software via adapter

2...99 (default 0)Switch, software via adapter

2...99 (default 0)Switch, software via adapter

–Data length cyclical

readwrite

1 Byte1 Byte

1 Byte1 Byte

1 Byte1 Byte

Profil – – –Transducer Block – – –Function Block(only for profil�conforming devices)

Control of the contactors and themanual motor starter

Control of the contactors and themanual motor starter

Control of the contactors and themanual motor starter

Device configurationcentral adjustment

local adustment

Fixed configuration

Fixed configuration

Fixed configuration

Fixed configuration

Software (e.g. PLC)

Potentiometer (time)

External supply Yes, but normally via hybrid bus cable Yes, but normally via hybrid bus cable Yes, but normally via hybrid bus cable

14

Page 15: Profibus DP ABB Certified Equipments Overview En

Devices overview 10/63�0.47 ENPROFIBUS DP

ControlIT, FieldIT Motor Management PROFIBUS Plug

UMC22-FBP PDP22-FBPData Sheet 2CDC135001D0202 2CDC192001D0201

Internet www.abb.com www.abb.comIndustrialIT enabled Yes Yes

Application Universal Motor Controller:Efficient control and protection of three�phase a.c. motors with elecronic measurement of the motor current and with some additional features such as blocking detection and others.

Motor current range:0.2...63 A(bar�type current transformers)

PROFIBUS DP Plug:Connection of devices with small to medium complexity to the PROFIBUS DP and to the 24 V AC supply (hybrid cable).

Examples for devices:Proximity switches, I/O modules, motor starter, softstarter, circuit breakers.

Ambient temperature 0...55 °C 0...55 °CType of protection IP 20 IP 67Explosion protection – –Registration CE, UL, CSA, GL, BV, LRS CE, UL, CSA, GL, BV, LRS

Physics RS 485Protocol PROFIBUS DPMax. Baud Rate via PROFIBUS Plug ≤ 12 Mbit/sIdent. No. PDP22-FBP be appliedPNO Certificate No. be appliedBus adress

local adjustmentcentral adjustment

2...99 (default 0)Panel

–Data length cyclical

readwrite

6 Byte4 Byte

Profil – seeTransducer Block – MSD11�FBP, MSR22�FBP,Function Block(only for profil�conforming devices)

Control of the contactors and themanual motor starter, motor current,additional I/O’s

MFI21�FBP or UMC22�FBP

Device configurationcentral adjustment

local adustment

Software (e.g. PLC)

Panel

External supply Yes, but normally via hybrid bus cable Yes, via hybrid bus cable

15

Page 16: Profibus DP ABB Certified Equipments Overview En

16

Devices overview 10/63�0.47 ENPROFIBUS DP

FieldIT, ControlIT Redundancy Link Module I/O System Remote I/O

RLM01 S900 S800Data Sheet 3BDD011641R0301 3BDD010420R0101 3BSE020924R101

Internet www.abb.com/fieldbus www.abb.com/control www.abb.com/controlIndustrialIT enabled Yes Yes Yes

Application PROFIBUS DP/FMS Redundancy Link Module.Converts a non redundant RS 485 PROFIBUS DP/FMS line to two redundant RS 485 PROFIBUS DP/FMS lines and vice versa (line redundancy).� Monitoring of communication� Transparent for DPV1 services� Status� and error display� Repeater functionality

I/O system for Zone 1 or Zone 2 applications.� Modular design with hot�pluggable

modules� Redundant in power supply,

communication interface and internal bus

� HART pass through

Remote I/O system for Zone 2 / Class 1 Div. 2 or Non�Ex applications.� Modular design� Comprehensive distributed system � Communication with parent controllers over industry�standard fieldbuses

Ambient temperature 0...50 °C �20...+60 °C +5...+55 °CType of protection IP 20 IP 20 IP 20Explosion protection – II 2 (1) G EEx [ia] ib IIC T4 and further [EEx ia] IIC, Class 1 Div. 2Registration CE, UL, CSA, Germanischer Lloyd for

operation in maritime systemsATEX, FM, GOST, CE ATEX, CSA, FM, GOST, CE

Physics RS 485 RS 485 RS 485Protocol PROFIBUS DP and FMS PROFIBUS DPV1 PROFIBUS DPMax. Baud Rate ≤ 12 Mbit/s ≤ 1.5 Mbit/s ≤ 12 Mbit/sIdent. No. – (transparent) 04D2 HEX 047C HEXPNO Certificate No. – – –Bus adress

local adjustmentcentral adjustment

– (transparent)––

0...126 (default 0)Switch

0...79Switch

–Data length cyclical

readwrite

––

together 0...216 Byte 0...244 Byte0...244 Byte

Profil – Remote I/O –Transducer Block – – –Function Block(only for profil�conforming devices)

– Analog: standard I/O, with/without HART and temperature free configurableDigital: standard I/O and EEx i low power valves incl. quitting

Analog: standard I/O and temperature (RTD and TC)Digital: standard I/O (24/48 V DC and 120/230 V AC), impulse totalizer (1.5 MHz) and relay output

Device configurationcentral adjustment

local adustment

Baud rate via switches

DTM(for FDT V1.2)

Software (e.g.: PLC)(DTM in preparation)

External supply Yes (redundant) Yes Yes

Page 17: Profibus DP ABB Certified Equipments Overview En

17

Devices overview 10/63�0.47 ENPROFIBUS DP

ControlIT Distributed Automation

I/O S500 PLC AC31: KT97, KT98Data Sheet 2CDC124003B0201 2CDC121008D0201

2CDC121009D0201Internet www.abb.com www.abb.comIndustrialIT enabled Yes Yes

Application Remote I/O system:� modular system,� bus module expandable with

up to 7 I/O modules� small expansion by extension box plugged into bus module � 2/3�wire connection, screw/spring� prepared for open fieldbus tech� nology with FieldBusPlug (FBP)

Compact PLC units for central and decentralized use,integrated 24 dig.In + 16 dig.Out + 8 config.dig. IO + 8 ana.In + 4 ana.Out, 2 serial interfaces (Modbus integrated), integrated CS31�Bus and up to 2 fieldbus�/communication�interfaces: PROFIBUS DP (Master or Slave) / DeviceNet / ARCNET / Ethernetuser memory: 480kB/1MB + 4MB SMCdirect connect. to OperateIT via OPC

Ambient temperature 0...55 °C 0...55 °CType of protection IP 20 IP 20Explosion protection – –Registration CE, cUL CE, UL, CSA, GL, DNV

Physics RS 485 RS 485Protocol PROFIBUS DP PROFIBUS DPMax. Baud Rate ≤ 12 Mbit/s ≤ 12 Mbit/sIdent. No. 9520 HEX 7504 HEXPNO Certificate No. Z00495, Z00496 –Bus adress

local adjustmentcentral adjustment

1...125DIP switch

0...126DIP switch

–Data length cyclical

readwrite

0...128 Byte0...128 Byte

0....244 Byte0....244 Byte

Profil – –Transducer Block – –Function Block(only for profil�conforming devices)

� Standard digital IN/OUT andconfigurable IN/OUT

� Standard analog IN/OUT� INTERFAST connection is usable

Programmable according IEC61131�3,multitasking with high performance,open and closed loop control,PI and PID controller, encoder input,32�bit integer and floating�point

Device configurationcentral adjustment

local adustment

Fieldbus configurator SW FB1131+ configurator integrated in PLCprogramming system AC1131

Fieldbus configurator SW FB1131+ configurator integrated in PLCprogramming system AC1131

External supply Yes Yes

Page 18: Profibus DP ABB Certified Equipments Overview En

10/6

3�0.

47 E

NR

ev. A

The IndustrialIT wordmark and all mentioned product names in the form XXXXXXIT are registered or pending trademarks of ABB.

ABB has Sales & Customer Supportexpertise in over 100 countries worldwide.

www.abb.com/fieldbusE-Mail: [email protected]

The Company’s policy is one of continuous productimprovement and the right is reserved to modify the

information contained herein without notice.