High performance (Isat) realizde by metal dust core.
Low profile:Thickness max.2.4/3.0/4.0/5.0mm
Low loss and low resistance
Capable of corresponding high frequency (1MHz)
※ Application
① Molding Choke; ④ Inductance Value:2R2=2.2µH;
② Mold Categories:W/F; ⑤ The Material Code;
③ Dimensions(unit:mm):6.0x6.0x3.0; ⑥ Material Type;
※ Shapes And Dimensions (unit:mm)
Unit:mm
Series A B C D E F I G H
MCW-0624-XXX-N2 6.95±0.35 6.6±0.2 3.0±0.3 2.2±0.2 0~+0.15 1.6±0.3 3.5 3.7 8.4
※ Regulation of Part number
MC - 0630 - 2R2 - N 2
① ② ③ ④ ⑤ ⑥
Product Presentation
DC/DC converters for laptop motherboards/CPU
100% lead (Pb) free meet RoHS standards
※ Features
Thin type of on-board power supply module for
Voltage regulator VRM for server
Http://www.hk-hotline.com
Unit:mm
Series A B C D E F I G H
MCW-0630-XXX-N2 6.95±0.35 6.6±0.2 3.0±0.3 2.8±0.2 0~+0.15 1.6±0.3 3.5 3.7 8.4
MCW-0650-XXX-N2 7.05±0.35 6.6±0.2 3.0±0.3 4.8±0.2 0~+0.15 1.6±0.3 3.5 3.7 8.4
MCF-1030-XXX-N2 11.15±0.35 10.0±0.3 3.0±0.5 2.8±0.2 0~+0.15 2.0±0.5 4.1 5.4 13.6
MCF-1040-XXX-N2 11.15±0.35 10.0±0.33.0±0.5/3.5±0.5
3.8±0.2 0~+0.15 2.0±0.5 4.1 5.4 13.6
MCF-1050-XXX-N2 11.15±0.35 10.0±0.33.0±0.5/3.5±0.5
4.8±0.2 0~+0.15 2.0±0.5 4.1 5.4 13.6
MCF-1350-XXX-N2 13.45±0.35 12.6±0.24.0±0.5/3.0±0.5
4.8±0.2 0~+0.15 2.0±0.5 5.0 8.0 14.5
Product Presentation
Http://www.hk-hotline.com
Heat RatingCurrent DC
Amps. Idc (A)
SaturationCurrent DC
Amps. Isat(A)
Typical Maximum Typical Typical
MCW-0624-R10-N2 0.10±20% 1.60 1.85 22.50 60.00
MCW-0624-R20-N2 0.20±20% 2.60 3.20 17.00 33.00
MCW-0624-R22-N2 0.22±20% 2.60 3.20 16.00 33.00
MCW-0624-R33-N2 0.33±20% 3.50 4.10 15.00 24.00
MCW-0624-R47-N2 0.47±20% 4.50 5.10 13.00 21.00
MCW-0624-R56-N2 0.56±20% 5.90 6.50 12.00 17.00
MCW-0624-R82-N2 0.82±20% 8.30 9.50 10.00 14.00
MCW-0624-1R0-N2 1.00±20% 11.20 13.50 9.00 16.00
MCW-0624-1R5-N2 1.50±20% 17.00 20.00 8.00 11.00
MCW-0624-2R2-N2 2.20±20% 23.00 28.00 6.00 9.00
MCW-0624-3R3-N2 3.30±20% 31.00 39.00 5.00 7.00
MCW-0624-4R7-N2 4.70±20% 41.00 50.00 4.00 6.00
MCW-0624-5R6-N2 5.60±20% 51.00 60.00 4.00 6.00
MCW-0624-6R8-N2 6.80±20% 57.00 70.00 4.00 5.00
MCW-0624-8R2-N2 8.20±20% 78.00 86.00 3.50 5.00
MCW-0624-100-N2 10.0±20% 92.00 101.00 3.10 4.00
MCW-0624-150-N2 15.0±20% 145 160.00 2.50 3.30
All test data is reference to 25 ambient.
Test Condition:100KHz,1.0Vrms
Idc: DC current (A) that will cause an approximate T of 40
Isat :DC current (A) that will cause L0 to drop approximately 30%
Operat between temperature range -55 to +125
The part temperature (ambient + temp rise ) should not exceed 125 under the worst case operating conditions.Circuit design, component.
PWB trace size and thickness, airflow and other cooling provision all affect the part temperature.Part temperature should be verified in the
end application.
The rated current as listed is either the saturation current or the heating current depending on which value is lower.
If you require another part number please contact with us.
※Note:
Product Presentation
MCW-0624-XXX-N2 Series
Rdc (mΩ) @25°C L0(uH)Inductance (µH)@(0A)
Part Number
Http://www.hk-hotline.com
Heat RatingCurrent DC
Amps. Idc (A)
SaturationCurrent DC
Amps. Isat(A)
Typical Maximum Typical Typical
MCW-0630-R10-N2 0.10±20% 1.50 1.70 32.50 60.00
MCW-0630-R15-N2 0.15±20% 1.90 2.50 30.00 40.00
MCW-0630-R20-N2 0.20±20% 2.40 3.00 21.00 34.00
MCW-0630-R22-N2 0.22±20% 2.50 3.00 21.00 34.00
MCW-0630-R33-N2 0.33±20% 3.00 3.50 21.00 25.00
MCW-0630-R36-N2 0.36±20% 3.30 3.90 19.00 22.00
MCW-0630-R47-N2 0.47±20% 3.50 4.10 18.00 20.00
MCW-0630-R56-N2 0.56±20% 4.25 4.90 15.00 18.00
MCW-0630-R68-N2 0.68±20% 5.00 5.70 14.00 17.00
MCW-0630-R82-N2 0.82±20% 6.00 6.90 12.00 16.00
MCW-0630-1R0-N2 1.00±20% 7.00 7.50 11.00 15.00
MCW-0630-1R2-N2 1.20±20% 8.00 10.50 10.00 12.00
MCW-0630-1R5-N2 1.50±20% 10.60 12.10 9.00 14.00
MCW-0630-1R8-N2 1.80±20% 14.00 16.00 7.50 13.00
MCW-0630-2R2-N2 2.20±20% 15.50 17.50 7.00 10.00
MCW-0630-2R5-N2 2.50±20% 16.00 18.00 6.50 10.00
MCW-0630-3R3-N2 3.30±20% 23.00 26.00 6.00 9.50
MCW-0630-4R7-N2 4.70±20% 34.50 38.00 5.00 6.50
MCW-0630-5R6-N2 5.60±20% 36.00 42.00 5.00 6.25
MCW-0630-6R8-N2 6.80±20% 50.00 54.00 4.50 6.00
MCW-0630-8R2-N2 8.20±20% 58.50 65.00 4.00 6.00
MCW-0630-100-N2 10.0±20% 64.00 68.00 4.00 5.00
MCW-0630-120-N2 12.0±20% 85.00 98.00 3.00 4.50
MCW-0630-150-N2 15.0±20% 98.00 115.00 2.80 3.80
MCW-0630-150A-N2 15.0±20% 106.00 115.00 2.60 3.80
MCW-0630-220-N2 22.0±20% 165.00 189.00 1.50 3.10
MCW-0630-330-N2 33.0±20% 225.00 257.00 1.00 2.90
All test data is reference to 25 ambient.
Test Condition:100KHz,1.0Vrms
Idc: DC current (A) that will cause an approximate T of 40
Isat :DC current (A) that will cause L0 to drop approximately 30%
Operat between temperature range -55 to +125
The part temperature (ambient + temp rise ) should not exceed 125 under the worst case operating conditions.Circuit design, component.
PWB trace size and thickness, airflow and other cooling provision all affect the part temperature.Part temperature should be verified in the
end application.
The rated current as listed is either the saturation current or the heating current depending on which value is lower.
If you require another part number please contact with us.
※Note:
Product Presentation
MCW-0630-XXX-N2 Series
Part Number L0(uH)
Inductance (µH)@(0A)
Rdc (mΩ) @25°C
Http://www.hk-hotline.com
Heat RatingCurrent DC
Amps. Idc (A)
SaturationCurrent DC
Amps. Isat(A)
Typical Maximum Typical Typical
MCW-0650-R13-N2 0.13±20% 1.00 1.20 42.00 48.00
MCW-0650-R22-N2 0.22±20% 1.10 1.30 30.00 35.00
MCW-0650-R36-N2 0.36±20% 2.70 3.10 21.00 25.00
MCW-0650-R40-N2 0.40±20% 3.20 3.50 20.00 23.00
MCW-0650-R47-N2 0.47±20% 3.25 3.75 20.00 21.00
MCW-0650-R56-N2 0.56±20% 3.40 3.60 20.00 18.00
MCW-0650-R68-N2 0.68±20% 3.90 4.20 18.00 16.00
MCW-0650-R82-N2 0.82±20% 4.60 4.90 16.50 17.00
MCW-0650-1R0-N2 1.00±20% 5.60 6.50 12.50 13.00
MCW-0650-1R2-N2 1.20±20% 6.00 7.50 12.00 13.00
MCW-0650-1R5-N2 1.50±20% 8.50 10.00 9.50 12.00
MCW-0650-2R2-N2 2.20±20% 11.20 12.50 9.00 10.00
MCW-0650-3R3-N2 3.30±20% 19.90 20.90 8.50 9.00
MCW-0650-4R7-N2 4.70±20% 26.00 29.00 6.00 8.00
MCW-0650-5R6-N2 5.60±20% 31.50 34.40 6.00 7.00
MCW-0650-6R8-N2 6.80±20% 36.50 41.00 5.50 6.00
MCW-0650-8R2-N2 8.20±20% 40.00 43.00 5.50 5.50
MCW-0650-100-N2 10.0±20% 54.00 60.00 4.50 5.30
MCW-0650-120-N2 12.0±20% 58.00 65.00 4.00 5.00
MCW-0650-150-N2 15.0±20% 78.00 90.00 3.10 4.00
MCW-0650-180-N2 18.0±20% 83.00 105.00 3.00 3.50
MCW-0650-220-N2 22.0±20% 120.00 140.00 2.60 3.50
MCW-0650-330-N2 33.0±20% 165.00 190.00 2.30 3.00
MCW-0650-470-N2 47.0±20% 250.00 290.00 2.00 2.80
All test data is reference to 25 ambient.
Test Condition:100KHz,1.0Vrms
Idc: DC current (A) that will cause an approximate T of 40
Isat :DC current (A) that will cause L0 to drop approximately 30%
Operat between temperature range -55 to +125
The part temperature (ambient + temp rise ) should not exceed 125 under the worst case operating conditions.Circuit design, component.
PWB trace size and thickness, airflow and other cooling provision all affect the part temperature.Part temperature should be verified in the
end application.
The rated current as listed is either the saturation current or the heating current depending on which value is lower.
If you require another part number please contact with us.
※Note:
Product Presentation
MCW-0650-XXX-N2 Series
Part Number L0(uH)
Inductance (µH)@(0A)
Rdc (mΩ) @25°C
Http://www.hk-hotline.com
Heat RatingCurrent DC
Amps. Idc (A)
SaturationCurrent DC
Amps. Isat(A)
Typical Maximum Typical Typical
MCF-1030-R22-N2 0.22±20% 1.07 1.20 30.00 50.00
MCF-1030-R24-N2 0.24±20% 1.10 1.27 30.00 50.00
MCF-1030-R33-N2 0.33±20% 1.30 1.60 23.00 32.00
MCF-1030-R36-N2 0.36±20% 1.30 1.60 23.00 28.00
MCF-1030-R47-N2 0.47±20% 2.10 2.50 23.00 26.00
MCF-1030-R56-N2 0.56±20% 2.40 3.00 22.00 24.00
MCF-1030-R68-N2 0.68±20% 2.90 3.40 21.00 23.00
MCF-1030-1R0-N2 1.00±20% 5.50 6.00 15.00 21.00
MCF-1030-1R5-N2 1.50±20% 6.50 7.50 12.00 18.00
MCF-1030-2R2-N2 2.20±20% 8.00 9.00 11.00 14.00
MCF-1030-3R3-N2 3.30±20% 14.50 16.00 9.00 12.00
MCF-1030-4R7-N2 4.70±20% 20.50 22.50 7.00 10.00
MCF-1030-5R6-N2 5.60±20% 27.00 30.00 6.00 10.00
MCF-1030-6R8-N2 6.80±20% 30.00 35.00 5.50 7.50
MCF-1030-8R2-N2 8.20±20% 35.00 45.00 5.00 7.00
MCF-1030-100-N2 10.0±20% 50.00 55.00 4.50 6.50
MCF-1030-150-N2 15.0±20% 59.00 65.00 4.00 5.00
MCF-1030-220-N2 22.0±20% 90.00 99.00 3.00 4.00
All test data is reference to 25 ambient.
Test Condition:100KHz,1.0Vrms
Idc: DC current (A) that will cause an approximate T of 40
Isat :DC current (A) that will cause L0 to drop approximately 30%
Operat between temperature range -55 to +125
The part temperature (ambient + temp rise ) should not exceed 125 under the worst case operating conditions.Circuit design, component.
PWB trace size and thickness, airflow and other cooling provision all affect the part temperature.Part temperature should be verified in the
end application.
The rated current as listed is either the saturation current or the heating current depending on which value is lower.
If you require another part number please contact with us.
※Note:
Product Presentation
MCF-1030-XXX-N2 Series
Part Number L0(uH)
Inductance (µH)@(0A)
Rdc (mΩ) @25°C
Http://www.hk-hotline.com
Heat RatingCurrent DC
Amps. Idc (A)
SaturationCurrent DC
Amps. Isat(A)
Typical Maximum Typical Typical
MCF-1040-R22-N2 0.22±20% 0.90 1.00 35.00 50.00
MCF-1040-R36-N2 0.36±20% 1.05 1.20 30.00 50.00
MCF-1040-R39-N2 0.39±20% 1.10 1.20 26.00 45.00
MCF-1040-R45-N2 0.45±20% 1.10 1.30 25.00 42.00
MCF-1040-R47-N2 0.47±20% 1.53 1.68 24.00 40.00
MCF-1040-R56-N2 0.56±20% 1.60 1.80 25.00 33.00
MCF-1040-R68-N2 0.68±20% 2.10 2.40 23.00 30.00
MCF-1040-1R0-N2 1.00±20% 3.00 3.30 18.00 28.00
MCF-1040-1R5-N2 1.50±20% 3.80 4.20 15.00 26.00
MCF-1040-1R8-N2 1.80±20% 5.00 5.80 13.00 15.00
MCF-1040-2R0-N2 2.00±20% 6.00 6.90 12.00 14.00
MCF-1040-2R2-N2 2.20±20% 6.00 7.00 12.00 18.00
MCF-1040-3R3-N2 3.30±20% 10.80 11.80 10.00 16.00
MCF-1040-4R7-N2 4.70±20% 17.00 20.00 8.50 13.00
MCF-1040-5R6-N2 5.60±20% 20.00 23.00 8.00 11.00
MCF-1040-6R8-N2 6.80±20% 22.50 25.00 7.00 10.00
MCF-1040-8R2-N2 8.20±20% 25.00 27.00 6.00 9.00
MCF-1040-100-N2 10.0±20% 27.00 30.00 7.50 8.50
MCF-1040-150-N2 15.0±20% 40.00 45.00 6.25 7.00
MCF-1040-220-N2 22.0±20% 60.00 66.00 5.00 5.50
MCF-1040-330-N2 33.0±20% 85.00 92.00 4.00 4.50
MCF-1040-470-N2 47.0±20% 130.00 145.00 3.30 3.50
MCF-1040-680-N2 68.0±20% 195.00 210.00 2.00 3.00
All test data is reference to 25 ambient.
Test Condition:100KHz,1.0Vrms
Idc: DC current (A) that will cause an approximate T of 40
Isat :DC current (A) that will cause L0 to drop approximately 30%
Operat between temperature range -55 to +125
The part temperature (ambient + temp rise ) should not exceed 125 under the worst case operating conditions.Circuit design, component.
PWB trace size and thickness, airflow and other cooling provision all affect the part temperature.Part temperature should be verified in the
end application.
The rated current as listed is either the saturation current or the heating current depending on which value is lower.
If you require another part number please contact with us.
※Note:
Product Presentation
MCF-1040-XXX-N2 Series
Part Number L0(uH)
Inductance (µH)@(0A)
Rdc (mΩ) @25°C
Http://www.hk-hotline.com
Heat RatingCurrent DC
Amps. Idc (A)
SaturationCurrent DC
Amps. Isat(A)
Typical Maximum Typical Typical
MCF-1050-6R8-N2 6.8±20% 18.00 20.00 8.00 15.0
MCF-1050-100-N2 10.0±20% 25.00 28.00 6.00 10.0
All test data is reference to 25 ambient.
Test Condition:100KHz,1.0Vrms
Idc: DC current (A) that will cause an approximate T of 40
Isat :DC current (A) that will cause L0 to drop approximately 30%
Operat between temperature range -55 to +125
The part temperature (ambient + temp rise ) should not exceed 125 under the worst case operating conditions.Circuit design, component.
PWB trace size and thickness, airflow and other cooling provision all affect the part temperature.Part temperature should be verified in the
end application.
The rated current as listed is either the saturation current or the heating current depending on which value is lower.
Heat RatingCurrent DC
Amps. Idc (A)
SaturationCurrent DC
Amps. Isat(A)
Typical Maximum Typical Typical
MCF-1350-R36-N2 0.36±20% 0.77 1.10 41.00 60.00
MCF-1350-R47-N2 0.47±20% 1.00 1.40 35.00 56.00
MCF-1350-1R0-N2 1.00±20% 1.90 2.20 26.00 35.00
MCF-1350-2R2-N2 2.20±20% 4.00 5.00 15.00 25.00
MCF-1350-3R3-N2 3.30±20% 7.50 9.00 12.00 23.00
MCF-1350-4R7-N2 4.70±20% 12.00 14.00 11.00 17.00
MCF-1350-5R6-N2 5.60±20% 13.00 15.00 10.50 15.00
MCF-1350-6R8-N2 6.80±20% 15.00 18.00 10.00 14.00
MCF-1350-8R2-N2 8.20±20% 17.00 20.00 9.00 13.00
MCF-1350-100-N2 10.0±20% 22.00 25.00 8.00 12.00
MCF-1350-470-N2 47.0±20% 100.00 140.00 3.00 5.00
All test data is reference to 25 ambient.
Test Condition:100KHz,1.0Vrms
Idc: DC current (A) that will cause an approximate T of 40
Isat :DC current (A) that will cause L0 to drop approximately 30%
Operat between temperature range -55 to +125
The part temperature (ambient + temp rise ) should not exceed 125 under the worst case operating conditions.Circuit design, component.
PWB trace size and thickness, airflow and other cooling provision all affect the part temperature.Part temperature should be verified in the
end application.
The rated current as listed is either the saturation current or the heating current depending on which value is lower.
※Note:
※Note:
Part Number L0(uH)
Inductance (µH)@(0A)
Rdc (mΩ) @25°C
If you require another part number please contact with us.
If you require another part number please contact with us.
MCF-1350-XXX-N2 Series
Product Presentation
MCF-1050-XXX-N2 Series
Part Number L0(uH)
Inductance (µH)@(0A)
Rdc (mΩ) @25°C
Http://www.hk-hotline.com
High performance (Isat) realizde by metal dust core.
Low profile:Thickness max.2.4/3.0/3.5/4.0/5.0 mm
Low loss and low resistance
Capable of corresponding high frequency (3MHz)
※ Application
① Molding Choke; ④ Inductance Value:2R2=2.2µH;
② Mold Categories:W/F; ⑤ The Material Code;
③ Dimensions(unit:mm):6.0x6.0x3.0; ⑥ Material Type;
※ Shapes And Dimensions (unit:mm)
Unit:mm
Series A B C D E F I G H
MCW-0624-XXX-S1 7.05±0.35 6.6±0.2 3.0±0.3 2.2±0.2 0~+0.15 1.6±0.3 3.5 3.7 8.4
① ② ③ ④ ⑤ ⑥
MC - 0630 - 2R2 - S 1
DC/DC converters for laptop motherboards/CPU
Thin type of on-board power supply module for
Voltage regulator VRM for server
※ Regulation of Part number
Product Presentation
※ Features
100% lead (Pb) free meet RoHS standards
Http://www.hk-hotline.com
Unit:mm
Series A B C D E F I G H
MCW-0630-XXX-S1 6.95±0.35 6.6±0.2 3.0±0.3 2.8±0.2 0~+0.15 1.6±0.3 3.5 3.7 8.4
MCW-0650-XXX-S1 7.05±0.35 6.6±0.2 3.0±0.3 4.8±0.2 0~+0.15 1.6±0.3 3.5 3.7 8.4
MCF-1040-XXX-S1 11.15±0.35 10.0±0.33.0±0.5/3.5±0.5
3.8±0.2 0~+0.15 2.0±0.5 4.1 5.4 13.6
MCF-1050-XXX-S1 11.15±0.35 10.0±0.33.0±0.5/3.5±0.5
4.8±0.2 0~+0.15 2.0±0.5 4.1 5.4 13.6
MCF-1335-XXX-S1 13.45±0.35 12.6±0.24.0±0.5/3.0±0.5
3.3±0.2 0~+0.15 2.0±0.5 5.0 8.0 14.5
MCF-1350-XXX-S1 13.45±0.35 12.6±0.24.0±0.5/3.0±0.5
4.8±0.2 0~+0.15 2.0±0.5 5.0 8.0 14.5
Product Presentation
Http://www.hk-hotline.com
Heat RatingCurrent DC
Amps. Idc (A)
SaturationCurrent DC
Amps. Isat(A)
Typical Maximum Typical Typical
1、 MCW-0624-R20-S1 0.20±20% 2.20 2.80 25.00 50.00
1、 MCW-0624-R22-S1 0.22±20% 2.60 3.20 21.00 34.00
1、 MCW-0624-R33-S1 0.33±20% 3.50 4.10 18.00 24.50
1、 MCW-0624-R47-S1 0.47±20% 4.50 5.10 15.00 22.00
1、 MCW-0624-R56-S1 0.56±20% 5.90 6.50 13.00 17.00
1、 MCW-0624-R68-S1 0.68±20% 7.50 8.50 11.00 22.00
1、 MCW-0624-R82-S1 0.82±20% 8.30 9.50 10.00 17.00
1、 MCW-0624-1R0-S1 1.00±20% 11.20 13.50 9.00 16.00
2、 MCW-0624-1R5-S1 1.50±20% 17.00 20.00 9.00 15.00
2、 MCW-0624-2R2-S1 2.20±20% 23.00 28.00 7.00 14.00
2、 MCW-0624-3R3-S1 3.30±20% 31.00 39.00 5.50 13.00
2、 MCW-0624-4R7-S1 4.70±20% 41.00 50.00 5.00 10.00
1、 MCW-0624-5R6-S1 5.60±20% 51.00 60.00 5.00 6.50
1、 MCW-0624-6R8-S1 6.80±20% 57.00 70.00 4.00 7.00
1、 MCW-0624-8R2-S1 8.20±20% 78.00 90.00 3.50 6.00
1、 MCW-0624-100-S1 10.0±20% 92.00 101.00 3.10 5.00
All test data is reference to 25 ambient.
Test Condition:100KHz,1.0Vrms
Idc: DC current (A) that will cause an approximate T of 40
Isat(1、) :DC current (A) that will cause L0 to drop approximately 20%
Isat (2、):DC current (A) that will cause L0 to drop approximately 30%
Operat between temperature range -55 to +125
The part temperature (ambient + temp rise ) should not exceed 125 under the worst case operating conditions.Circuit design, component.
PWB trace size and thickness, airflow and other cooling provision all affect the part temperature.Part temperature should be verified in the
end application.
The rated current as listed is either the saturation current or the heating current depending on which value is lower.
If you require another part number please contact with us.
※Note:
Product Presentation
MCW-0624-XXX-S1 Series
Part Number L0(uH)
Inductance (µH)@(0A)
Rdc (mΩ) @25°C
Http://www.hk-hotline.com
Heat RatingCurrent DC
Amps. Idc (A)
SaturationCurrent DC
Amps. Isat(A)
Typical Maximum Typical Typical
MCW-0630-R10-S1 0.10±20% 1.50 1.70 32.50 60.00
MCW-0630-R15-S1 0.15±20% 1.70 2.00 30.00 60.00
MCW-0630-R20-S1 0.20±20% 2.40 3.00 24.00 41.00
MCW-0630-R22-S1 0.22±20% 2.50 2.80 23.00 40.00
MCW-0630-R25-S1 0.25±20% 3.00 3.50 21.00 39.00
MCW-0630-R33-S1 0.33±20% 3.50 3.90 20.00 30.00
MCW-0630-R47-S1 0.47±20% 4.00 4.20 17.50 26.00
MCW-0630-R56-S1 0.56±20% 4.70 5.00 16.50 25.50
MCW-0630-R68-S1 0.68±20% 5.00 5.50 15.50 25.00
MCW-0630-R75-S1 0.75±20% 5.40 6.20 14.00 24.50
MCW-0630-R82-S1 0.82±20% 6.70 8.00 13.00 24.00
MCW-0630-1R0-S1 1.00±20% 9.00 10.00 11.00 22.00
MCW-0630-1R2-S1 1.20±20% 10.00 12.00 10.00 20.00
MCW-0630-1R5-S1 1.50±20% 14.00 15.00 9.00 18.00
MCW-0630-2R0-S1 1.80±20% 16.00 18.00 8.20 14.00
MCW-0630-2R2-S1 2.20±20% 18.00 20.00 8.00 14.00
MCW-0630-2R5-S1 2.50±20% 20.00 22.00 7.00 14.00
MCW-0630-3R3-S1 3.30±20% 28.00 30.00 6.00 13.50
MCW-0630-4R7-S1 4.70±20% 37.00 40.00 5.50 10.00
MCW-0630-5R6-S1 5.60±20% 39.00 42.00 5.50 9.00
MCW-0630-6R8-S1 6.80±20% 54.00 60.00 4.50 8.00
MCW-0630-8R2-S1 8.20±20% 56.00 62.00 4.00 6.00
MCW-0630-100-S1 10.0±20% 62.00 68.00 4.00 5.50
MCW-0630-120-S1 12.0±20% 85.00 95.00 3.30 5.00
MCW-0630-150-S1 15.0±20% 96.00 110.00 3.00 4.00
All test data is reference to 25 ambient.
Test Condition:100KHz,1.0Vrms
Idc: DC current (A) that will cause an approximate T of 40
Isat :DC current (A) that will cause L0 to drop approximately 20%
Operat between temperature range -55 to +125
The part temperature (ambient + temp rise ) should not exceed 125 under the worst case operating conditions.Circuit design, component.
PWB trace size and thickness, airflow and other cooling provision all affect the part temperature.Part temperature should be verified in the
end application.
The rated current as listed is either the saturation current or the heating current depending on which value is lower.
If you require another part number please contact with us.
※Note:
Product Presentation
MCW-0630-XXX-S1 Series
Part Number L0(uH)
Inductance (µH)@(0A)
Rdc (mΩ) @25°C
Http://www.hk-hotline.com
Heat RatingCurrent DC
Amps. Idc (A)
SaturationCurrent DC
Amps. Isat(A)
Typical Maximum Typical Typical
MCW-0650-R20-S1 0.20±20% 0.90 1.20 32.00 50.0
MCW-0650-R22-S1 0.22±20% 1.20 1.40 30.00 50.0
MCW-0650-R36-S1 0.36±20% 3.00 3.50 16.50 35.0
MCW-0650-R40-S1 0.40±20% 3.40 3.80 16.00 27.0
MCW-0650-R47-S1 0.47±20% 3.50 3.90 15.50 30.0
MCW-0650-R56-S1 0.56±20% 3.70 4.20 15.00 22.0
MCW-0650-R68-S1 0.68±20% 4.10 4.80 14.00 21.0
MCW-0650-R82-S1 0.82±20% 5.00 6.00 13.50 20.0
MCW-0650-1R0-S1 1.00±20% 5.60 6.50 13.00 18.0
MCW-0650-1R2-S1 1.20±20% 6.70 7.50 12.00 13.0
MCW-0650-1R5-S1 1.50±20% 7.50 8.50 10.00 12.0
MCW-0650-2R2-S1 2.20±20% 11.00 13.60 9.00 15.0
MCW-0650-3R3-S1 3.30±20% 19.90 20.90 7.00 13.0
MCW-0650-4R7-S1 4.70±20% 26.00 28.00 6.00 12.0
MCW-0650-5R6-S1 5.60±20% 31.50 34.40 5.50 11.0
MCW-0650-6R8-S1 6.80±20% 40.00 43.00 5.00 10.0
MCW-0650-8R2-S1 8.20±20% 45.00 49.00 4.50 9.0
MCW-0650-100-S1 10.0±20% 54.00 60.00 4.10 8.0
MCW-0650-120-S1 12.0±20% 57.00 65.00 3.90 7.0
MCW-0650-150-S1 15.0±20% 74.00 85.00 3.40 6.0
MCW-0650-180-S1 18.0±20% 81.00 95.00 3.00 5.0
MCW-0650-220-S1 22.0±20% 125.00 140.00 2.60 4.5
MCW-0650-330-S1 33.0±20% 160.00 185.00 2.30 4.0
MCW-0650-470-S1 47.0±20% 250.00 280.00 1.80 3.5
All test data is reference to 25 ambient.
Test Condition:100KHz,1.0Vrms
Idc: DC current (A) that will cause an approximate T of 40
Isat :DC current (A) that will cause L0 to drop approximately 25%
Operat between temperature range -55 to +125
The part temperature (ambient + temp rise ) should not exceed 125 under the worst case operating conditions.Circuit design, component.
PWB trace size and thickness, airflow and other cooling provision all affect the part temperature.Part temperature should be verified in the
end application.
The rated current as listed is either the saturation current or the heating current depending on which value is lower.
If you require another part number please contact with us.
※Note:
Product Presentation
MCW-0650-XXX-S1 Series
Part Number L0(uH)
Inductance (µH)@(0A)
Rdc (mΩ) @25°C
Http://www.hk-hotline.com
Heat RatingCurrent DC
Amps. Idc (A)
SaturationCurrent DC
Amps. Isat(A)
Typical Maximum Typical Typical
MCF-1040-R22-S1 0.22±20% 0.90 1.00 35.00 60.00
MCF-1040-R36-S1 0.36±20% 1.05 1.20 30.00 50.00
MCF-1040-R39-S1 0.39±20% 1.10 1.30 30.00 60.00
MCF-1040-R41-S1 0.41±20% 1.10 1.30 30.00 60.00
MCF-1040-R45-S1 0.45±20% 1.10 1.30 29.00 45.00
MCF-1040-R47-S1 0.47±20% 1.60 1.80 26.00 40.00
MCF-1040-R56-S1 0.56±20% 1.60 1.80 26.00 33.00
MCF-1040-R68-S1 0.68±20% 2.40 2.70 22.00 39.00
MCF-1040-R88-S1 0.88±20% 2.70 3.00 20.00 38.00
MCF-1040-1R0-S1 1.00±20% 3.00 3.30 18.00 36.00
MCF-1040-1R5-S1 1.50±20% 3.80 4.20 16.00 33.00
MCF-1040-2R2-S1 2.20±20% 7.00 8.00 12.00 27.00
MCF-1040-3R3-S1 3.30±20% 10.80 11.80 10.00 18.70
MCF-1040-4R7-S1 4.70±20% 15.00 16.50 9.50 17.00
MCF-1040-5R6-S1 5.60±20% 17.00 19.30 9.00 14.00
MCF-1040-6R8-S1 6.80±20% 19.00 23.30 8.50 13.50
MCF-1040-8R2-S1 8.20±20% 20.00 22.50 8.00 12.50
MCF-1040-100-S1 10.0±20% 27.00 30.00 7.50 12.00
MCF-1040-150-S1 15.0±20% 40.00 45.00 6.25 9.00
MCF-1040-220-S1 22.0±20% 64.00 74.00 5.00 7.00
MCF-1040-270-S1 27.0±20% 86.00 100.00 4.00 6.00
MCF-1040-330-S1 33.0±20% 98.00 112.00 3.50 5.00
MCF-1040-470-S1 47.0±20% 145.00 167.00 3.00 4.50
MCF-1040-680-S1 68.0±20% 205.00 240.00 2.00 4.00
MCF-1040-820-S1 82.0±20% 270.00 300.00 1.50 3.00
All test data is reference to 25 ambient.
Test Condition:100KHz,1.0Vrms
Idc: DC current (A) that will cause an approximate T of 40
Isat :DC current (A) that will cause L0 to drop approximately 20%
Operat between temperature range -55 to +125
The part temperature (ambient + temp rise ) should not exceed 125 under the worst case operating conditions.Circuit design, component.
PWB trace size and thickness, airflow and other cooling provision all affect the part temperature.Part temperature should be verified in the
end application.
The rated current as listed is either the saturation current or the heating current depending on which value is lower.
If you require another part number please contact with us.
※Note:
Product Presentation
MCF-1040-XXX-S1 Series
Part Number L0(uH)
Inductance (µH)@(0A)
Rdc (mΩ) @25°C
Http://www.hk-hotline.com
Heat RatingCurrent DC
Amps. Idc (A)
SaturationCurrent DC
Amps. Isat(A)
Typical Maximum Typical Typical
MCF-1050-R33-S1 0.33±20% 0.90 1.00 30.00 42.0
MCF-1050-R36-S1 0.36±20% 0.95 1.10 30.00 40.0
MCF-1050-R56-S1 0.56±20% 1.45 1.60 28.00 38.0
All test data is reference to 25 ambient.
Test Condition:100KHz,1.0Vrms
Idc: DC current (A) that will cause an approximate T of 40
Isat :DC current (A) that will cause L0 to drop approximately 20%
Operat between temperature range -55 to +125
The part temperature (ambient + temp rise ) should not exceed 125 under the worst case operating conditions.Circuit design, component.
PWB trace size and thickness, airflow and other cooling provision all affect the part temperature.Part temperature should be verified in the
end application.
The rated current as listed is either the saturation current or the heating current depending on which value is lower.
If you require another part number please contact with us.
※Note:
Product Presentation
MCF-1050-XXX-S1 Series
Part Number L0(uH)
Inductance (µH)@(0A)
Rdc (mΩ) @25°C
Http://www.hk-hotline.com
Heat RatingCurrent DC
Amps. Idc (A)
SaturationCurrent DC
Amps. Isat(A)
Typical Maximum Typical Typical
MCF-1335-R15-S1 0.15±20% 0.70 0.85 39.00 68.00
MCF-1335-R22-S1 0.22±20% 1.10 1.30 38.00 65.00
MCF-1335-R33-S1 0.33±20% 1.30 1.50 36.50 62.00
MCF-1335-R39-S1 0.39±20% 1.30 1.50 34.00 60.00
MCF-1335-R47-S1 0.47±20% 1.70 2.00 32.00 55.00
MCF-1335-R56-S1 0.56±20% 1.80 2.20 29.00 51.00
MCF-1335-R60-S1 0.60±20% 1.80 2.20 29.00 51.00
MCF-1335-R62-S1 0.62±20% 1.80 2.20 29.00 51.00
MCF-1335-R68-S1 0.68±20% 2.30 2.50 28.00 49.00
MCF-1335-R82-S1 0.82±20% 2.60 3.00 25.00 44.00
MCF-1335-1R0-S1 1.00±20% 3.30 3.50 24.00 37.00
MCF-1335-1R5-S1 1.50±20% 5.10 5.50 19.00 35.00
MCF-1335-2R2-S1 2.20±20% 7.20 8.00 16.00 27.00
MCF-1335-3R3-S1 3.30±20% 10.00 12.00 13.00 22.00
MCF-1335-4R7-S1 4.70±20% 16.00 18.00 9.00 20.00
MCF-1335-5R6-S1 5.60±20% 19.00 22.00 8.00 16.00
MCF-1335-6R8-S1 6.80±20% 21.00 25.00 7.00 15.00
MCF-1335-8R2-S1 8.20±20% 25.00 30.00 6.50 14.00
MCF-1335-100-S1 10.0±20% 29.00 35.00 6.00 12.00
All test data is reference to 25 ambient.
Test Condition:100KHz,1.0Vrms
Idc: DC current (A) that will cause an approximate T of 40
Isat :DC current (A) that will cause L0 to drop approximately 20%
Operat between temperature range -55 to +125
The part temperature (ambient + temp rise ) should not exceed 125 under the worst case operating conditions.Circuit design, component.
PWB trace size and thickness, airflow and other cooling provision all affect the part temperature.Part temperature should be verified in the
end application.
The rated current as listed is either the saturation current or the heating current depending on which value is lower.
Product Presentation
If you require another part number please contact with us.
※Note:
MCF-1335-XXX-S1 Series
Part Number L0(uH)
Inductance (µH)@(0A)
Rdc (mΩ) @25°C
Http://www.hk-hotline.com
Heat RatingCurrent DC
Amps. Idc (A)
SaturationCurrent DC
Amps. Isat(A)
Typical Maximum Typical Typical
MCF-1350-R22-S1 0.22±20% 0.60 0.75 42.00 76.00
MCF-1350-R36-S1 0.36±20% 0.77 1.10 41.00 75.00
MCF-1350-R47-S1 0.47±20% 1.10 1.30 38.00 65.00
MCF-1350-R50-S1 0.50±20% 1.20 1.50 36.00 55.00
MCF-1350-R56-S1 0.56±20% 1.20 1.50 36.00 55.00
MCF-1350-R62-S1 0.62±20% 1.50 1.70 34.00 54.00
MCF-1350-R68-S1 0.68±20% 1.50 1.70 34.00 54.00
MCF-1350-R82-S1 0.82±20% 1.80 2.10 31.00 53.00
MCF-1350-1R0-S1 1.00±20% 2.10 2.50 29.00 50.00
MCF-1350-1R2-S1 1.20±20% 2.60 3.20 25.00 45.00
MCF-1350-1R5-S1 1.50±20% 3.40 4.10 23.00 43.00
MCF-1350-2R2-S1 2.20±20% 4.60 5.50 20.00 32.00
MCF-1350-3R3-S1 3.30±20% 7.70 9.20 15.00 30.00
MCF-1350-4R7-S1 4.70±20% 12.80 15.00 12.00 25.00
MCF-1350-5R6-S1 5.60±20% 14.00 16.50 11.50 23.00
MCF-1350-6R8-S1 6.80±20% 15.40 18.50 11.00 21.00
MCF-1350-8R2-S1 8.20±20% 19.00 22.00 9.50 18.00
MCF-1350-100-S1 10.0±20% 22.00 25.00 8.00 15.00
All test data is reference to 25 ambient.
Test Condition:100KHz,1.0Vrms
Idc: DC current (A) that will cause an approximate T of 40
Isat :DC current (A) that will cause L0 to drop approximately 20%
Operat between temperature range -55 to +125
The part temperature (ambient + temp rise ) should not exceed 125 under the worst case operating conditions.Circuit design, component.
PWB trace size and thickness, airflow and other cooling provision all affect the part temperature.Part temperature should be verified in the
end application.
The rated current as listed is either the saturation current or the heating current depending on which value is lower.
Product Presentation
If you require another part number please contact with us.
※Note:
MCF-1350-XXX-S1 Series
Part Number L0(uH)
Inductance (µH)@(0A)
Rdc (mΩ) @25°C
Http://www.hk-hotline.com
High performance (Isat) realizde by metal dust core.
Low profile:Thickness max.1.2/1.5/1.8/2.0/2.4/3.0 /3.5/4.0/4.5/5.0/6.0/7.0mm
Low loss and low resistance
Capable of corresponding high frequency (1MHz)
※ Application
① Molding Choke; ④ Inductance Value:2R2=2.2µH;
② Mold Categories:W/F; ⑤ The Material Code;
③ Dimensions(unit:mm):6.0x6.0x3.0; ⑥ Material Type;
※ Shapes And Dimensions (unit:mm)
Unit:mm
Series A B C D E F I G H
MCW-0412-XXX-S2 4.4±0.35 4.2±0.25 2.0±0.3 1.0±0.2 0~+0.15 0.8±0.3 2.5 2.2 5.2
MC - 0630 - 2R2 - S 2
① ② ③ ④ ⑤ ⑥
DC/DC converters for laptop motherboards/CPU
Thin type of on-board power supply module for
Voltage regulator VRM for server
※ Regulation of Part number
Product Presentation
※ Features
100% lead (Pb) free meet RoHS standards
Http://www.hk-hotline.com
Unit:mm
Series A B C D E F I G H
MCW-0415-XXX-S2 4.4±0.35 4.2±0.25 2.0±0.3 1.3±0.2 0~+0.15 0.8±0.3 2.5 2.2 5.2
MCW-0420-XXX-S2 4.4±0.35 4.2±0.25 2.0±0.3 1.8±0.2 0~+0.15 0.8±0.3 2.5 2.2 5.2
MCW-0512-XXX-S2 5.4±0.35 5.2±0.2 2.3±0.3 1.0±0.2 0~+0.15 1.0±0.3 2.5 2.2 5.99
MCW-0515-XXX-S2 5.4±0.35 5.2±0.2 2.3±0.3 1.3±0.2 0~+0.15 1.0±0.3 2.5 2.2 5.99
MCW-0518-XXX-S2 5.4±0.35 5.2±0.2 2.3±0.3 1.6±0.2 0~+0.15 1.0±0.3 2.5 2.2 5.99
MCW-0520-XXX-S2 5.4±0.35 5.2±0.2 2.3±0.3 1.8±0.2 0~+0.15 1.0±0.3 2.5 2.2 5.99
MCW-0530-XXX-S2 5.4±0.35 5.2±0.2 2.3±0.3 2.8±0.2 0~+0.15 1.0±0.3 2.5 2.2 5.99
MCW-0612-XXX-S2 7.05±0.35 6.6±0.2 3.0±0.3 1.0±0.2 0~+0.15 1.6±0.3 3.5 3.7 8.4
MCW-0615-XXX-S2 7.05±0.35 6.6±0.2 3.0±0.3 1.3±0.2 0~+0.15 1.6±0.3 3.5 3.7 8.4
MCW-0618-XXX-S2 7.05±0.35 6.6±0.2 3.0±0.3 1.6±0.2 0~+0.15 1.6±0.3 3.5 3.7 8.4
MCW-0620-XXX-S2 7.05±0.35 6.6±0.2 3.0±0.3 1.8±0.2 0~+0.15 1.6±0.3 3.5 3.7 8.4
MCW-0624-XXX-S2 7.05±0.35 6.6±0.2 3.0±0.3 2.2±0.2 0~+0.15 1.6±0.3 3.5 3.7 8.4
MCW-0630-XXX-S2 6.95±0.35 6.6±0.2 3.0±0.3 2.8±0.2 0~+0.15 1.6±0.3 3.5 3.7 8.4
MCW-0650-XXX-S2 7.05±0.35 6.6±0.2 3.0±0.3 4.8±0.2 0~+0.15 1.6±0.3 3.5 3.7 8.4
MCF-1030-XXX-S2 11.15±0.35 10.0±0.3 3.5±0.5 2.8±0.2 0~+0.15 2.0±0.5 4.1 5.4 13.6
MCF-1040-XXX-S2 11.15±0.35 10.0±0.33.0±0.5/3.5±0.5
3.8±0.2 0~+0.15 2.0±0.5 4.1 5.4 13.6
MCF-1045-XXX-S2 11.15±0.35 10.0±0.33.0±0.5/3.5±0.5
4.3±0.2 0~+0.15 2.0±0.5 4.1 5.4 13.6
MCF-1050-XXX-S2 11.15±0.35 10.0±0.33.0±0.5/3.5±0.5
4.8±0.2 0~+0.15 2.0±0.5 4.1 5.4 13.6
MCF-1335-XXX-S2 13.45±0.35 12.6±0.24.0±0.5/3.0±0.5
3.3±0.2 0~+0.15 2.0±0.5 5.0 8.0 14.5
MCF-1350-XXX-S2 13.45±0.35 12.6±0.24.0±0.5/3.0±0.5
4.8±0.2 0~+0.15 2.0±0.5 5.0 8.0 14.5
MCF-1360-XXX-S2 13.45±0.35 12.6±0.24.0±0.5/3.0±0.5
5.8±0.2 0~+0.15 2.0±0.5 5.0 8.0 14.5
MCF-1770-XXX-S2 17.15±0.35 17.0±0.3 12±0.3 6.8±0.2 0~+0.30 2.5±0.5 12.8 11.2 18.2
Product Presentation
Http://www.hk-hotline.com
Heat RatingCurrent DC
Amps. Idc (A)
SaturationCurrent DC
Amps. Isat(A)
Typical Maximum Typical Typical
MCW-0412-R33-S2 0.33±20% 17.00 19.00 6.50 8.40
MCW-0412-R47-S2 0.47±20% 19.00 21.00 6.00 6.80
MCW-0412-R68-S2 0.68±20% 32.00 36.00 4.50 6.00
MCW-0412-1R0-S2 1.00±20% 43.00 47.00 4.20 5.20
MCW-0412-1R5-S2 1.50±20% 68.00 75.00 3.25 4.00
MCW-0412-2R2-S2 2.20±20% 79.40 83.50 2.75 3.50
MCW-0412-4R7-S2 4.70±20% 175.00 195.00 1.80 2.80
All test data is reference to 25 ambient.
Test Condition:100KHz,1.0Vrms
Idc: DC current (A) that will cause an approximate T of 40
Isat:DC current (A) that will cause L0 to drop approximately 30%
Operat between temperature range -55 to +125
The part temperature (ambient + temp rise ) should not exceed 125 under the worst case operating conditions.Circuit design, component.
PWB trace size and thickness, airflow and other cooling provision all affect the part temperature.Part temperature should be verified in the
end application.
The rated current as listed is either the saturation current or the heating current depending on which value is lower.
Heat RatingCurrent DC
Amps. Idc (A)
SaturationCurrent DC
Amps. Isat(A)
Typical Maximum Typical Typical
MCW-0415-R22-S2 0.22±20% 7.80 9.00 7.00 14.00
MCW-0415-1R5-S2 1.5±20% 49.00 63.00 4.00 6.00
All test data is reference to 25 ambient.
Test Condition:100KHz,1.0Vrms
Idc: DC current (A) that will cause an approximate T of 40
Isat:DC current (A) that will cause L0 to drop approximately 30%
Operat between temperature range -55 to +125
The part temperature (ambient + temp rise ) should not exceed 125 under the worst case operating conditions.Circuit design, component.
PWB trace size and thickness, airflow and other cooling provision all affect the part temperature.Part temperature should be verified in the
end application.
The rated current as listed is either the saturation current or the heating current depending on which value is lower.
If you require another part number please contact with us.
※Note:
If you require another part number please contact with us.
MCW-0415-XXX-S2 Series
Part Number L0(uH)
Inductance (µH)@(0A)
Rdc (mΩ) @25°C
※Note:
Product Presentation
MCW-0412-XXX-S2 Series
Part Number L0(uH)
Inductance (µH)@(0A)
Rdc (mΩ) @25°C
Http://www.hk-hotline.com
Heat RatingCurrent DC
Amps. Idc (A)
SaturationCurrent DC
Amps. Isat(A)
Typical Maximum Typical Typical
MCW-0420-R10-S2 0.10±20% 3.50 4.00 12.00 30.00
MCW-0420-R22-S2 0.22±20% 6.00 6.60 9.00 12.50
MCW-0420-R47-S2 0.47±20% 12.50 14.00 7.00 10.50
MCW-0420-R56-S2 0.56±20% 14.00 16.00 6.50 10.00
MCW-0420-R68-S2 0.68±20% 16.00 18.00 6.00 9.00
MCW-0420-1R0-S2 1.00±20% 24.00 27.00 4.50 7.00
MCW-0420-1R2-S2 1.20±20% 24.00 27.00 4.50 7.00
MCW-0420-1R5-S2 1.50±20% 38.00 46.00 4.00 6.00
MCW-0420-2R2-S2 2.20±20% 52.00 58.00 3.00 5.00
MCW-0420-3R3-S2 3.30±20% 74.00 87.00 2.50 4.00
MCW-0420-4R7-S2 4.70±20% 92.00 105.00 2.20 3.00
MCW-0420-6R8-S2 6.80±20% 162.00 178.00 2.00 2.50
MCW-0420-8R2-S2 8.20.±20% 188.00 207.00 1.80 2.00
MCW-0420-100-S2 10.0±20% 256.00 282.00 1.60 1.80
All test data is reference to 25 ambient.
Test Condition:100KHz,1.0Vrms
Idc: DC current (A) that will cause an approximate T of 40
Isat :DC current (A) that will cause L0 to drop approximately 30%
Operat between temperature range -55 to +125
The part temperature (ambient + temp rise ) should not exceed 125 under the worst case operating conditions.Circuit design, component.
PWB trace size and thickness, airflow and other cooling provision all affect the part temperature.Part temperature should be verified in the
end application.
The rated current as listed is either the saturation current or the heating current depending on which value is lower.
If you require another part number please contact with us.
※Note:
Product Presentation
MCW-0420-XXX-S2 Series
Part Number L0(uH)
Inductance (µH)@(0A)
Rdc (mΩ) @25°C
Http://www.hk-hotline.com
Heat RatingCurrent DC
Amps. Idc (A)
SaturationCurrent DC
Amps. Isat(A)
Typical Maximum Typical Typical
MCW-0512-1R0-S2 1.00±20% 32.00 36.80 5.10 7.60
MCW-0512-2R2-S2 2.20±20% 67.00 76.00 3.50 4.00
MCW-0512-3R3-S2 3.30±20% 85.00 98.00 3.00 3.70
MCW-0512-4R7-S2 4.70±20% 145.00 163.00 2.30 3.40
MCW-0512-6R8-S2 6.80±20% 225.00 250.00 2.00 2.30
Heat RatingCurrent DC
Amps. Idc (A)
SaturationCurrent DC
Amps. Isat(A)
Typical Maximum Typical Typical
MCW-0515-R33-S2 0.33±20% 8.00 9.00 10.00 15.00
MCW-0515-1R0-S2 1.00±20% 20.00 23.00 6.50 9.00
MCW-0515-1R2-S2 1.20±20% 29.30 33.70 5.30 8.00
MCW-0515-2R2-S2 2.20±20% 58.00 64.00 3.30 6.00
MCW-0515-3R3-S2 3.30±20% 65.00 72.00 3.20 5.00
MCW-0515-4R7-S2 4.70±20% 95.00 106.00 3.00 4.00
MCW-0515-6R8-S2 6.80±20% 120.00 130.00 2.50 3.20
MCW-0515-100-S2 10.0±20% 153.00 170.00 2.00 3.00
MCW-0515-150-S2 15.0±20% 310.00 350.00 1.00 2.30
All test data is reference to 25 ambient.
Test Condition:100KHz,1.0Vrms
Idc: DC current (A) that will cause an approximate T of 40
Isat :DC current (A) that will cause L0 to drop approximately 30%
Operat between temperature range -55 to +125
The part temperature (ambient + temp rise ) should not exceed 125 under the worst case operating conditions.Circuit design, component.
PWB trace size and thickness, airflow and other cooling provision all affect the part temperature.Part temperature should be verified in the
end application.
The rated current as listed is either the saturation current or the heating current depending on which value is lower.
If you require another part number please contact with us.
※Note:
If you require another part number please contact with us.
MCW-0515-XXX-S2 Series
Part Number L0(uH)
Inductance (µH)@(0A)
Rdc (mΩ) @25°C
Product Presentation
MCW-0512-XXX-S2 Series
Part Number L0(uH)
Inductance (µH)@(0A)
Rdc (mΩ) @25°C
Http://www.hk-hotline.com
Heat RatingCurrent DC
Amps. Idc (A)
SaturationCurrent DC
Amps. Isat(A)
Typical Maximum Typical Typical
MCW-0518-R47-S2 0.47±20% 7.70 9.00 10.50 15.50
MCW-0518-R56-S2 0.56±20% 8.00 10.00 9.50 15.00
MCW-0518-R68-S2 0.68±20% 12.00 18.00 8.90 11.20
MCW-0518-1R0-S2 1.00±20% 15.00 17.00 8.00 9.00
MCW-0518-1R2-S2 1.20±20% 17.00 20.00 7.50 8.00
MCW-0518-2R2-S2 2.20±20% 30.00 35.00 5.00 6.50
MCW-0518-3R3-S2 3.30±20% 52.00 58.00 4.50 5.00
MCW-0518-4R7-S2 4.70±20% 78.00 85.00 3.50 4.00
MCW-0518-6R8-S2 6.80±20% 107.00 120.00 2.80 3.40
MCW-0518-8R2-S2 8.20±20% 131.00 145.00 2.60 3.10
MCW-0518-100-S2 10.0±20% 140.00 155.00 2.50 3.00
All test data is reference to 25 ambient.
Test Condition:100KHz,1.0Vrms
Idc: DC current (A) that will cause an approximate T of 40
Isat :DC current (A) that will cause L0 to drop approximately 30%
Operat between temperature range -55 to +125
The part temperature (ambient + temp rise ) should not exceed 125 under the worst case operating conditions.Circuit design, component.
PWB trace size and thickness, airflow and other cooling provision all affect the part temperature.Part temperature should be verified in the
end application.
The rated current as listed is either the saturation current or the heating current depending on which value is lower.
If you require another part number please contact with us.
※Note:
Product Presentation
MCW-0518-XXX-S2 Series
Part Number L0(uH)
Inductance (µH)@(0A)
Rdc (mΩ) @25°C
Http://www.hk-hotline.com
Heat RatingCurrent DC
Amps. Idc (A)
SaturationCurrent DC
Amps. Isat(A)
Typical Maximum Typical Typical
MCW-0520-R22-S2 0.22±20% 3.80 4.50 15.00 18.70
MCW-0520-R56-S2 0.56±20% 8.00 10.00 9.50 15.00
MCW-0520-R68-S2 0.68±20% 12.00 18.00 8.90 11.20
MCW-0520-1R0-S2 1.00±20% 15.00 17.00 8.00 9.00
MCW-0520-1R5-S2 1.50±20% 25.00 30.00 5.50 8.00
MCW-0520-2R2-S2 2.20±20% 30.00 34.00 4.20 7.00
MCW-0520-3R3-S2 3.30±20% 52.00 58.00 4.50 5.00
MCW-0520-4R7-S2 4.70±20% 70.00 78.00 2.80 3.50
MCW-0520-6R8-S2 6.80±20% 107.00 120.00 2.80 3.40
MCW-0520-8R2-S2 8.20±20% 131.00 145.00 2.60 3.10
MCW-0520-100-S2 10.0±20% 140.00 155.00 2.50 3.00
All test data is reference to 25 ambient.
Test Condition:100KHz,1.0Vrms
Idc: DC current (A) that will cause an approximate T of 40
Isat :DC current (A) that will cause L0 to drop approximately 30%
Operat between temperature range -55 to +125
The part temperature (ambient + temp rise ) should not exceed 125 under the worst case operating conditions.Circuit design, component.
PWB trace size and thickness, airflow and other cooling provision all affect the part temperature.Part temperature should be verified in the
end application.
The rated current as listed is either the saturation current or the heating current depending on which value is lower.
If you require another part number please contact with us.
※Note:
Product Presentation
MCW-0520-XXX-S2 Series
Part Number L0(uH)
Inductance (µH)@(0A)
Rdc (mΩ) @25°C
Http://www.hk-hotline.com
Heat RatingCurrent DC
Amps. Idc (A)
SaturationCurrent DC
Amps. Isat(A)
Typical Maximum Typical Typical
MCW-0530-R47-S2 0.47±20% 6.50 7.50 12.00 15.00
MCW-0530-R68-S2 0.68±20% 11.00 12.00 8.50 14.00
MCW-0530-R75-S2 0.75±20% 12.00 13.00 8.00 12.00
MCW-0530-1R0-S2 1.00±20% 13.00 14.00 7.00 11.00
MCW-0530-1R2-S2 1.20±20% 15.00 16.00 6.50 11.00
MCW-0530-1R5-S2 1.50±20% 17.00 22.00 6.00 9.50
MCW-0530-2R2-S2 2.20±20% 27.00 33.00 5.50 9.00
MCW-0530-3R3-S2 3.30±20% 32.00 38.00 5.00 6.50
MCW-0530-4R7-S2 4.70±20% 50.00 60.00 4.00 5.00
MCW-0530-5R6-S2 4.70±20% 55.00 63.00 3.80 4.50
MCW-0530-6R8-S2 6.80±20% 69.00 76.00 3.50 4.30
MCW-0530-8R2-S2 8.20±20% 80.00 105.00 3.25 4.00
MCW-0530-100-S2 10.0±20% 115.00 130.00 2.70 3.50
MCW-0530-150-S2 15.0±20% 150.00 165.00 1.80 2.20
All test data is reference to 25 ambient.
Test Condition:100KHz,1.0Vrms
Idc: DC current (A) that will cause an approximate T of 40
Isat :DC current (A) that will cause L0 to drop approximately 30%
Operat between temperature range -55 to +125
The part temperature (ambient + temp rise ) should not exceed 125 under the worst case operating conditions.Circuit design, component.
PWB trace size and thickness, airflow and other cooling provision all affect the part temperature.Part temperature should be verified in the
end application.
The rated current as listed is either the saturation current or the heating current depending on which value is lower.
If you require another part number please contact with us.
※Note:
Product Presentation
MCW-0530-XXX-S2 Series
Part Number L0(uH)
Inductance (µH)@(0A)
Rdc (mΩ) @25°C
Http://www.hk-hotline.com
Heat RatingCurrent DC
Amps. Idc (A)
SaturationCurrent DC
Amps. Isat(A)
Typical Maximum Typical Typical
MCW-0612-R56-S2 0.56±20% 13.50 15.50 7.00 11.00
MCW-0612-R68-S2 0.68±20% 15.00 17.50 6.70 9.00
MCW-0612-R82-S2 0.82±20% 21.50 24.50 6.30 8.00
MCW-0612-1R0-S2 1.00±20% 25.00 29.00 6.00 7.50
MCW-0612-2R2-S2 2.20±20% 51.50 59.00 4.00 5.00
MCW-0612-3R3-S2 3.30±20% 80.00 92.00 3.00 4.00
MCW-0612-4R7-S2 4.70±20% 106.00 122.00 2.70 3.50
MCW-0612-6R8-S2 6.80±20% 185.00 210.00 2.20 2.80
MCW-0612-100-S2 10.0±20% 250.00 290.00 2.00 2.20
All test data is reference to 25 ambient.
Test Condition:100KHz,1.0Vrms
Idc: DC current (A) that will cause an approximate T of 40
Isat :DC current (A) that will cause L0 to drop approximately 30%
Operat between temperature range -55 to +125
The part temperature (ambient + temp rise ) should not exceed 125 under the worst case operating conditions.Circuit design, component.
PWB trace size and thickness, airflow and other cooling provision all affect the part temperature.Part temperature should be verified in the
end application.
The rated current as listed is either the saturation current or the heating current depending on which value is lower.
If you require another part number please contact with us.
※Note:
Product Presentation
MCW-0612-XXX-S2 Series
Part Number L0(uH)
Inductance (µH)@(0A)
Rdc (mΩ) @25°C
Http://www.hk-hotline.com
Heat RatingCurrent DC
Amps. Idc (A)
SaturationCurrent DC
Amps. Isat(A)
Typical Maximum Typical Typical
MCW-0615-R33-S2 0.33±20% 6.80 7.80 10.00 19.50
MCW-0615-R47-S2 0.47±20% 7.30 8.50 9.80 16.00
MCW-0615-R56-S2 0.56±20% 9.50 11.00 9.00 14.00
MCW-0615-R68-S2 0.68±20% 10.50 12.00 8.50 12.00
MCW-0615-R82-S2 0.82±20% 15.00 17.00 7.00 10.00
MCW-0615-1R0-S2 1.00±20% 18.50 21.00 5.50 9.00
MCW-0615-1R2-S2 1.20±20% 25.00 30.00 5.40 8.50
MCW-0615-2R2-S2 2.20±20% 46.00 54.00 3.50 6.00
MCW-0615-3R3-S2 3.30±20% 54.00 63.00 3.30 5.50
MCW-0615-4R7-S2 4.70±20% 76.00 85.00 3.20 5.00
MCW-0615-6R8-S2 6.80±20% 125.00 135.00 2.50 4.00
MCW-0615-100-S2 10.0±20% 165.00 175.00 2.00 3.00
All test data is reference to 25 ambient.
Test Condition:100KHz,1.0Vrms
Idc: DC current (A) that will cause an approximate T of 40
Isat :DC current (A) that will cause L0 to drop approximately 30%
Operat between temperature range -55 to +125
The part temperature (ambient + temp rise ) should not exceed 125 under the worst case operating conditions.Circuit design, component.
PWB trace size and thickness, airflow and other cooling provision all affect the part temperature.Part temperature should be verified in the
end application.
The rated current as listed is either the saturation current or the heating current depending on which value is lower.
If you require another part number please contact with us.
※Note:
Product Presentation
MCW-0615-XXX-S2 Series
Part Number L0(uH)
Inductance (µH)@(0A)
Rdc (mΩ) @25°C
Http://www.hk-hotline.com
Heat RatingCurrent DC
Amps. Idc (A)
SaturationCurrent DC
Amps. Isat(A)
Typical Maximum Typical Typical
MCW-0618-R10-S2 0.10±20% 6.80 2.50 18.00 45.00
MCW-0618-R22-S2 0.22±20% 4.50 5.20 14.00 29.00
MCW-0618-R33-S2 0.33±20% 5.20 6.80 12.00 22.00
MCW-0618-R47-S2 0.47±20% 7.30 8.40 11.00 18.00
MCW-0618-R68-S2 0.68±20% 10.80 12.70 9.00 17.00
MCW-0618-1R0-S2 1.00±20% 14.50 17.00 7.00 14.00
MCW-0618-1R5-S2 1.50±20% 20.00 26.00 6.50 12.00
MCW-0618-2R0-S2 2.00±20% 28.00 32.00 6.00 13.00
MCW-0618-2R2-S2 2.20±20% 31.00 35.00 6.00 13.00
MCW-0618-3R3-S2 3.30±20% 56.00 60.00 3.50 10.00
MCW-0618-4R7-S2 4.70±20% 68.00 70.00 3.50 5.00
MCW-0618-6R8-S2 6.80±20% 101.00 110.00 2.80 3.50
MCW-0618-8R2-S2 8.20±20% 120.00 135.00 2.50 3.00
MCW-0618-100-S2 10.0±20% 140.00 155.00 2.30 2.50
MCW-0618-150-S2 15.0±20% 215.00 250.00 1.80 2.20
All test data is reference to 25 ambient.
Test Condition:100KHz,1.0Vrms
Idc: DC current (A) that will cause an approximate T of 40
Isat :DC current (A) that will cause L0 to drop approximately 30%
Operat between temperature range -55 to +125
The part temperature (ambient + temp rise ) should not exceed 125 under the worst case operating conditions.Circuit design, component.
PWB trace size and thickness, airflow and other cooling provision all affect the part temperature.Part temperature should be verified in the
end application.
The rated current as listed is either the saturation current or the heating current depending on which value is lower.
If you require another part number please contact with us.
※Note:
Product Presentation
MCW-0618-XXX-S2 Series
Part Number L0(uH)
Inductance (µH)@(0A)
Rdc (mΩ) @25°C
Http://www.hk-hotline.com
Heat RatingCurrent DC
Amps. Idc (A)
SaturationCurrent DC
Amps. Isat(A)
Typical Maximum Typical Typical
MCW-0620-1R0-S2 1.00±20% 9.80 10.80 8.00 12.50
MCW-0620-1R5-S2 1.50±20% 20.00 24.00 6.50 10.50
MCW-0620-2R2-S2 2.20±20% 24.40 27.50 5.50 8.00
MCW-0620-3R3-S2 3.30±20% 40.00 43.00 4.00 7.00
MCW-0620-4R7-S2 4.70±20% 62.00 65.00 3.50 5.50
Heat RatingCurrent DC
Amps. Idc (A)
SaturationCurrent DC
Amps. Isat(A)
Typical Maximum Typical Typical
MCW-0624-R47-S2 0.47±20% 4.5 5.1 14 22
MCW-0624-1R0-S2 1.00±20% 11.20 13.50 9.00 15.00
MCW-0624-3R3-S2 3.30±20% 30.00 36.00 5.50 7.50
MCW-0624-4R7-S2 4.70±20% 40.00 48.00 5.00 6.50
MCW-0624-6R8-S2 6.80±20% 57.00 70.00 3.60 5.50
MCW-0624-100-S2 10.0±20% 88.00 95.00 3.10 4.50
All test data is reference to 25 ambient.
Test Condition:100KHz,1.0Vrms
Idc: DC current (A) that will cause an approximate T of 40
Isat :DC current (A) that will cause L0 to drop approximately 30%
Operat between temperature range -55 to +125
The part temperature (ambient + temp rise ) should not exceed 125 under the worst case operating conditions.Circuit design, component.
PWB trace size and thickness, airflow and other cooling provision all affect the part temperature.Part temperature should be verified in the
end application.
The rated current as listed is either the saturation current or the heating current depending on which value is lower.
If you require another part number please contact with us.
※Note:
If you require another part number please contact with us.
MCW-0624-XXX-S2 Series
Part Number L0(uH)
Inductance (µH)@(0A)
Rdc (mΩ) @25°C
Product Presentation
MCW-0620-XXX-S2 Series
Part Number L0(uH)
Inductance (µH)@(0A)
Rdc (mΩ) @25°C
Http://www.hk-hotline.com
Heat RatingCurrent DC
Amps. Idc (A)
SaturationCurrent DC
Amps. Isat(A)
Typical Maximum Typical Typical
MCW-0630-R15-S2 0.15±20% 1.80 2.40 30.00 50.00
MCW-0630-R22-S2 0.22±20% 2.40 2.80 22.00 34.00
MCW-0630-R36-S2 0.36±20% 3.00 3.50 20.00 26.00
MCW-0630-R47-S2 0.47±20% 3.50 4.10 18.00 22.00
MCW-0630-R56-S2 0.56±20% 3.80 4.50 15.00 17.00
MCW-0630-R68-S2 0.68±20% 4.80 5.50 14.00 18.00
MCW-0630-R82-S2 0.82±20% 5.20 7.00 13.00 17.00
MCW-0630-1R0-S2 1.00±20% 6.70 7.40 12.00 16.00
MCW-0630-1R2-S2 1.20±20% 7.00 8.00 12.00 14.00
MCW-0630-1R5-S2 1.50±20% 10.60 12.10 9.00 15.00
MCW-0630-2R2-S2 2.20±20% 14.00 16.00 7.50 11.00
MCW-0630-3R3-S2 3.30±20% 22.00 25.00 6.50 10.00
MCW-0630-4R7-S2 4.70±20% 28.00 32.00 5.50 8.00
MCW-0630-5R6-S2 5.60±20% 33.00 38.00 5.00 7.00
MCW-0630-6R8-S2 6.80±20% 45.00 50.00 4.50 6.50
MCW-0630-8R2-S2 8.20±20% 58.50 65.00 4.00 5.50
MCW-0630-100-S2 10.0±20% 62.00 68.00 4.00 5.00
MCW-0630-120-S2 12.0±20% 85.00 98.00 3.00 5.00
MCW-0630-150-S2 15.0±20% 98.00 115.00 2.50 4.00
MCW-0630-220-S2 22.0±20% 165.00 185.00 2.00 3.60
MCW-0630-330-S2 33.0±20% 225.00 257.00 1.50 3.10
All test data is reference to 25 ambient.
Test Condition:100KHz,1.0Vrms
Idc: DC current (A) that will cause an approximate T of 40
Isat :DC current (A) that will cause L0 to drop approximately 30%
Operat between temperature range -55 to +125
The part temperature (ambient + temp rise ) should not exceed 125 under the worst case operating conditions.Circuit design, component.
PWB trace size and thickness, airflow and other cooling provision all affect the part temperature.Part temperature should be verified in the
end application.
The rated current as listed is either the saturation current or the heating current depending on which value is lower.
If you require another part number please contact with us.
※Note:
Product Presentation
MCW-0630-XXX-S2 Series
Part Number L0(uH)
Inductance (µH)@(0A)
Rdc (mΩ) @25°C
Http://www.hk-hotline.com
Heat RatingCurrent DC
Amps. Idc (A)
SaturationCurrent DC
Amps. Isat(A)
Typical Maximum Typical Typical
MCW-0650-1R0-S2 1.00±20% 6.00 6.50 12.00 14.00
MCW-0650-1R2-S2 1.20±20% 6.00 7.50 11.00 13.00
MCW-0650-1R5-S2 1.50±20% 7.00 8.00 10.00 12.00
MCW-0650-2R2-S2 2.20±20% 10.00 11.50 9.50 10.50
MCW-0650-3R3-S2 3.30±20% 16.00 18.00 8.50 9.50
MCW-0650-4R7-S2 4.70±20% 23.00 26.00 6.50 7.00
MCW-0650-5R6-S2 5.60±20% 26.00 29.00 6.00 7.50
MCW-0650-6R8-S2 6.80±20% 32.00 36.00 5.50 7.00
MCW-0650-8R2-S2 8.20±20% 40.00 43.00 5.50 6.00
MCW-0650-100-S2 10.0±20% 48.00 55.00 4.50 5.50
MCW-0650-150-S2 15.0±20% 72.00 80.00 3.50 4.00
MCW-0650-180-S2 15.0±20% 82.00 98.00 3.10 4.00
MCW-0650-220-S2 22.0±20% 105.00 125.00 2.80 3.50
MCW-0650-330-S2 33.0±20% 180.00 155.00 2.20 3.00
MCW-0650-470-S2 47.0±20% 2500.00 290.00 1.80 2.80
All test data is reference to 25 ambient.
Test Condition:100KHz,1.0Vrms
Idc: DC current (A) that will cause an approximate T of 40
Isat :DC current (A) that will cause L0 to drop approximately 30%
Operat between temperature range -55 to +125
The part temperature (ambient + temp rise ) should not exceed 125 under the worst case operating conditions.Circuit design, component.
PWB trace size and thickness, airflow and other cooling provision all affect the part temperature.Part temperature should be verified in the
end application.
The rated current as listed is either the saturation current or the heating current depending on which value is lower.
If you require another part number please contact with us.
※Note:
Product Presentation
MCW-0650-XXX-S2 Series
Part Number L0(uH)
Inductance (µH)@(0A)
Rdc (mΩ) @25°C
Http://www.hk-hotline.com
Heat RatingCurrent DC
Amps. Idc (A)
SaturationCurrent DC
Amps. Isat(A)
Typical Maximum Typical Typical
MCF-1030-R22-S2 0.22±20% 1.07 1.20 30.00 50.00
MCF-1030-R33-S2 0.33±20% 1.30 1.60 23.00 32.00
MCF-1030-R36-S2 0.36±20% 1.30 1.60 23.00 28.00
MCF-1030-R47-S2 0.47±20% 2.10 2.50 23.00 26.00
MCF-1030-R56-S2 0.56±20% 2.40 3.00 22.00 24.00
MCF-1030-R68-S2 0.68±20% 2.90 3.40 21.00 23.00
MCF-1030-1R0-S2 1.00±20% 5.30 6.00 15.00 21.00
MCF-1030-1R5-S2 1.50±20% 6.50 7.50 12.00 20.00
MCF-1030-2R2-S2 2.20±20% 8.00 9.00 11.00 15.00
MCF-1030-3R3-S2 3.30±20% 14.50 16.00 9.00 13.00
MCF-1030-4R7-S2 4.70±20% 20.50 22.50 7.00 11.00
MCF-1030-5R6-S2 5.60±20% 27.00 30.00 6.00 10.00
MCF-1030-6R8-S2 6.80±20% 30.00 35.00 5.50 9.00
MCF-1030-8R2-S2 8.20±20% 35.00 45.00 5.00 8.50
MCF-1030-100-S2 10.0±20% 50.00 55.00 4.50 7.50
MCF-1030-150-S2 15.0±20% 56.00 62.00 4.00 6.00
MCF-1030-220-S2 22.0±20% 90.00 99.00 3.00 5.00
All test data is reference to 25 ambient.
Test Condition:100KHz,1.0Vrms
Idc: DC current (A) that will cause an approximate T of 40
Isat :DC current (A) that will cause L0 to drop approximately 30%
Operat between temperature range -55 to +125
The part temperature (ambient + temp rise ) should not exceed 125 under the worst case operating conditions.Circuit design, component.
PWB trace size and thickness, airflow and other cooling provision all affect the part temperature.Part temperature should be verified in the
end application.
The rated current as listed is either the saturation current or the heating current depending on which value is lower.
If you require another part number please contact with us.
※Note:
Product Presentation
MCF-1030-XXX-S2 Series
Part Number L0(uH)
Inductance (µH)@(0A)
Rdc (mΩ) @25°C
Http://www.hk-hotline.com
Heat RatingCurrent DC
Amps. Idc (A)
SaturationCurrent DC
Amps. Isat(A)
Typical Maximum Typical Typical
MCF-1040-R22-S2 0.22±20% 0.85 0.95 35.00 60.00
MCF-1040-R36-S2 0.36±20% 1.05 1.20 30.00 60.00
MCF-1040-R45-S2 0.45±20% 1.10 1.30 25.00 45.00
MCF-1040-R56-S2 0.56±20% 1.60 1.80 25.00 40.00
MCF-1040-R68-S2 0.68±20% 1.80 2.30 24.00 35.00
MCF-1040-R78-S2 0.78±20% 2.00 2.40 22.00 33.00
MCF-1040-1R0-S2 1.00±20% 2.30 2.50 20.00 29.00
MCF-1040-1R5-S2 1.50±20% 3.80 4.20 15.00 27.00
MCF-1040-2R2-S2 2.20±20% 6.50 7.00 12.00 20.00
MCF-1040-3R3-S2 3.30±20% 9.80 10.80 10.50 17.00
MCF-1040-4R7-S2 4.70±20% 13.00 15.00 9.00 15.00
MCF-1040-5R6-S2 5.60±20% 16.00 18.00 8.50 13.00
MCF-1040-6R8-S2 6.80±20% 18.00 21.00 8.00 11.00
MCF-1040-8R2-S2 8.20±20% 22.00 24.00 6.50 10.00
MCF-1040-100-S2 10.0±20% 24.00 27.00 6.00 9.00
MCF-1040-150-S2 15.0±20% 36.00 42.00 7.00 8.00
MCF-1040-180-S2 18.0±20% 40.00 45.00 6.25 7.00
MCF-1040-220-S2 22.0±20% 60.00 66.00 5.00 6.00
MCF-1040-330-S2 33.0±20% 85.00 92.00 4.00 5.00
MCF-1040-470-S2 47.0±20% 136.00 145.00 3.30 4.00
MCF-1040-680-S2 68.0±20% 190.00 205.00 2.30 4.00
MCF-1040-820-S2 82.0±20% 262.00 280.00 2.00 3.50
MCF-1040-101-S2 100.0±20% 280.00 300.00 1.50 3.00
All test data is reference to 25 ambient.
Test Condition:100KHz,1.0Vrms
Idc: DC current (A) that will cause an approximate T of 40
Isat :DC current (A) that will cause L0 to drop approximately 30%
Operat between temperature range -55 to +125
The part temperature (ambient + temp rise ) should not exceed 125 under the worst case operating conditions.Circuit design, component.
PWB trace size and thickness, airflow and other cooling provision all affect the part temperature.Part temperature should be verified in the
end application.
The rated current as listed is either the saturation current or the heating current depending on which value is lower.
If you require another part number please contact with us.
※Note:
Product Presentation
MCF-1040-XXX-S2 Series
Part Number L0(uH)
Inductance (µH)@(0A)
Rdc (mΩ) @25°C
Http://www.hk-hotline.com
Heat RatingCurrent DC
Amps. Idc (A)
SaturationCurrent DC
Amps. Isat(A)
Typical Maximum Typical Typical
MCF-1045-3R3-S2 3.30±20% 9.00 10.00 11.00 19.00
MCF-1045-101-S2 10.0±20% 278.00 300.00 1.80 2.80
All test data is reference to 25 ambient.
Test Condition:100KHz,1.0Vrms
Idc: DC current (A) that will cause an approximate T of 40
Isat :DC current (A) that will cause L0 to drop approximately 30%
Operat between temperature range -55 to +125
The part temperature (ambient + temp rise ) should not exceed 125 under the worst case operating conditions.Circuit design, component.
PWB trace size and thickness, airflow and other cooling provision all affect the part temperature.Part temperature should be verified in the
end application.
The rated current as listed is either the saturation current or the heating current depending on which value is lower.
Heat RatingCurrent DC
Amps. Idc (A)
SaturationCurrent DC
Amps. Isat(A)
Typical Maximum Typical Typical
MCF-1050-6R8-S2 6.80±20% 16.50 19.00 8.50 15.00
MCF-1050-100-S2 10.0±20% 23.00 27.00 7.50 11.00
MCF-1050-220-S2 22.0±20% 41.00 46.00 6.00 7.00
MCF-1050-270-S2 27.0±20% 59.00 65.00 5.00 6.50
MCF-1050-330-S2 33.0±20% 63.00 70.00 4.50 6.00
MCF-1050-470-S2 47.0±20% 106.00 115.00 3.50 4.50
All test data is reference to 25 ambient.
Test Condition:100KHz,1.0Vrms
Idc: DC current (A) that will cause an approximate T of 40
Isat :DC current (A) that will cause L0 to drop approximately 30%
Operat between temperature range -55 to +125
The part temperature (ambient + temp rise ) should not exceed 125 under the worst case operating conditions.Circuit design, component.
PWB trace size and thickness, airflow and other cooling provision all affect the part temperature.Part temperature should be verified in the
end application.
The rated current as listed is either the saturation current or the heating current depending on which value is lower.
If you require another part number please contact with us.
※Note:
If you require another part number please contact with us.
MCF-1050-XXX-S2 Series
Part Number L0(uH)
Inductance (µH)@(0A)
Rdc (mΩ) @25°C
※Note:
Product Presentation
MCF-1045-XXX-S2 Series
Part Number L0(uH)
Inductance (µH)@(0A)
Rdc (mΩ) @25°C
Http://www.hk-hotline.com
Heat RatingCurrent DC
Amps. Idc (A)
SaturationCurrent DC
Amps. Isat(A)
Typical Maximum Typical Typical
MCF-1335-R22-S2 0.22±20% 1.00 1.20 38.00 55.00
MCF-1335-R56-S2 0.56±20% 1.70 2.00 29.00 44.00
MCF-1335-R68-S2 0.68±20% 2.00 2.30 28.00 42.00
MCF-1335-R82-S2 0.82±20% 2.50 2.90 25.00 37.00
MCF-1335-1R0-S2 1.00±20% 3.00 3.40 24.00 34.00
MCF-1335-1R2-S2 1.20±20% 3.30 3.80 20.00 27.00
MCF-1335-1R5-S2 1.50±20% 4.10 4.70 18.00 26.00
MCF-1335-2R2-S2 2.20±20% 6.00 6.90 14.00 20.00
MCF-1335-3R3-S2 3.30±20% 8.30 9.50 13.00 16.00
MCF-1335-4R7-S2 4.70±20% 15.00 17.00 9.00 15.00
MCF-1335-5R6-S2 5.60±20% 18.30 19.00 8.00 14.00
MCF-1335-6R8-S2 6.80±20% 19.80 22.00 7.00 13.00
MCF-1335-8R2-S2 8.20±20% 24.80 28.00 6.50 12.00
MCF-1335-100-S2 10.0±20% 26.00 29.00 6.00 10.00
All test data is reference to 25 ambient.
Test Condition:100KHz,1.0Vrms
Idc: DC current (A) that will cause an approximate T of 40
Isat :DC current (A) that will cause L0 to drop approximately 30%
Operat between temperature range -55 to +125
The part temperature (ambient + temp rise ) should not exceed 125 under the worst case operating conditions.Circuit design, component.
PWB trace size and thickness, airflow and other cooling provision all affect the part temperature.Part temperature should be verified in the
end application.
The rated current as listed is either the saturation current or the heating current depending on which value is lower.
If you require another part number please contact with us.
※Note:
Product Presentation
MCF-1335-XXX-S2 Series
Part Number L0(uH)
Inductance (µH)@(0A)
Rdc (mΩ) @25°C
Http://www.hk-hotline.com
Heat RatingCurrent DC
Amps. Idc (A)
SaturationCurrent DC
Amps. Isat(A)
Typical Maximum Typical Typical
MCF-1350-R36-S2 0.36±20% 0.74 0.85 42.00 60.00
MCF-1350-R47-S2 0.47±20% 0.90 1.30 38.00 60.00
MCF-1350-R50-S2 0.50±20% 1.00 1.15 38.00 50.00
MCF-1350-R56-S2 0.56±20% 1.25 1.35 35.00 48.00
MCF-1350-R68-S2 0.68±20% 1.35 1.55 33.00 46.00
MCF-1350-R82-S2 0.82±20% 1.45 1.67 30.00 39.00
MCF-1350-1R0-S2 1.00±20% 1.90 2.20 26.00 42.00
MCF-1350-1R5-S2 1.50±20% 2.80 3.20 23.00 32.00
MCF-1350-1R8-S2 1.80±20% 2.80 3.20 23.00 27.00
MCF-1350-2R2-S2 2.20±20% 4.00 5.00 15.00 24.00
MCF-1350-3R3-S2 3.30±20% 7.50 8.50 13.00 23.00
MCF-1350-4R7-S2 4.70±20% 10.00 12.00 12.00 22.00
MCF-1350-5R6-S2 5.60±20% 12.00 15.00 11.50 18.00
MCF-1350-6R8-S2 6.80±20% 14.00 17.00 11.00 17.00
MCF-1350-8R2-S2 8.20±20% 16.00 20.00 10.00 15.00
MCF-1350-100-S2 10.0±20% 19.00 22.00 9.00 12.00
MCF-1350-150-S2 15.0±20% 30.00 35.00 6.00 9.00
MCF-1350-220-S2 22.0±20% 51.00 58.00 4.50 6.50
MCF-1350-270-S2 27.0±20% 58.00 66.00 4.00 6.30
MCF-1350-330-S2 33.0±20% 75.00 84.00 3.50 6.00
MCF-1350-470-S2 47.0±20% 116.00 130.00 3.00 5.00
All test data is reference to 25 ambient.
Test Condition:100KHz,1.0Vrms
Idc: DC current (A) that will cause an approximate T of 40
Isat :DC current (A) that will cause L0 to drop approximately 30%
Operat between temperature range -55 to +125
The part temperature (ambient + temp rise ) should not exceed 125 under the worst case operating conditions.Circuit design, component.
PWB trace size and thickness, airflow and other cooling provision all affect the part temperature.Part temperature should be verified in the
end application.
The rated current as listed is either the saturation current or the heating current depending on which value is lower.
If you require another part number please contact with us.
※Note:
Product Presentation
MCF-1350-XXX-S2 Series
Part Number L0(uH)
Inductance (µH)@(0A)
Rdc (mΩ) @25°C
Http://www.hk-hotline.com
Heat RatingCurrent DC
Amps. Idc (A)
SaturationCurrent DC
Amps. Isat(A)
Typical Maximum Typical Typical
MCF-1360-6R8-S2 6.80±20% 10.00 13.80 11.50 15.00
MCF-1360-8R2-S2 8.20±20% 13.60 16.00 11.00 13.50
MCF-1360-100-S2 10.0±20% 18.00 20.70 10.00 12.50
MCF-1360-120-S2 12.0±20% 20.00 23.00 7.00 10.00
MCF-1360-150-S2 15.0±20% 25.00 29.00 6.00 9.00
MCF-1360-180-S2 18.0±20% 30.00 35.00 5.00 8.00
MCF-1360-220-S2 22.0±20% 34.00 39.50 5.00 7.50
MCF-1360-270-S2 27.0±20% 49.00 56.00 4.00 6.50
MCF-1360-330-S2 33.0±20% 65.00 75.00 4.00 6.00
MCF-1360-470-S2 47.0±20% 80.00 90.00 3.50 5.50
MCF-1360-680-S2 68.0±20% 115.00 130.00 3.25 4.50
MCF-1360-820-S2 82.0±20% 120.00 140.00 3.00 4.00
MCF-1360-101-S2 100.0±20% 180.00 200.00 2.50 3.50
MCF-1360-121-S2 120.0±20% 210.00 235.00 2.30 3.20
MCF-1360-151-S2 150.0±20% 300.00 350.00 2.00 2.70
All test data is reference to 25 ambient.
Test Condition:100KHz,1.0Vrms
Idc: DC current (A) that will cause an approximate T of 40
Isat :DC current (A) that will cause L0 to drop approximately 30%
Operat between temperature range -55 to +125
The part temperature (ambient + temp rise ) should not exceed 125 under the worst case operating conditions.Circuit design, component.
PWB trace size and thickness, airflow and other cooling provision all affect the part temperature.Part temperature should be verified in the
end application.
The rated current as listed is either the saturation current or the heating current depending on which value is lower.
If you require another part number please contact with us.
※Note:
Product Presentation
MCF-1360-XXX-S2 Series
Part Number L0(uH)
Inductance (µH)@(0A)
Rdc (mΩ) @25°C
Http://www.hk-hotline.com
Heat RatingCurrent DC
Amps. Idc (A)
SaturationCurrent DC
Amps. Isat(A)
Typical Maximum Typical Typical
MCF-1770-1R5-S2 1.50±20% 1.85 2.15 40.00 40.00
MCF-1770-2R2-S2 2.20±20% 2.15 2.50 37.00 34.00
MCF-1770-4R7-S2 4.70±20% 4.12 4.72 27.00 24.00
MCF-1770-6R8-S2 6.80±20% 6.55 7.55 20.00 22.00
MCF-1770-8R2-S2 8.20±20% 8.10 8.70 16.00 20.00
MCF-1770-100-S2 10.0±20% 9.30 10.00 14.00 18.00
MCF-1770-150-S2 15.0±20% 14.50 15.00 12.00 13.00
MCF-1770-200-S2 20.0±20% 19.50 21.90 9.70 12.00
MCF-1770-220-S2 22.0±20% 20.50 23.00 9.50 11.00
MCF-1770-330-S2 33.0±20% 35.10 37.00 9.00 10.00
MCF-1770-470-S2 47.0±20% 41.00 47.00 6.80 7.50
MCF-1770-680-S2 68.0±20% 74.00 85.00 5.20 6.50
All test data is reference to 25 ambient.
Test Condition:100KHz,1.0Vrms
Idc: DC current (A) that will cause an approximate T of 40
Isat :DC current (A) that will cause L0 to drop approximately 30%
Operat between temperature range -55 to +125
The part temperature (ambient + temp rise ) should not exceed 125 under the worst case operating conditions.Circuit design, component.
PWB trace size and thickness, airflow and other cooling provision all affect the part temperature.Part temperature should be verified in the
end application.
The rated current as listed is either the saturation current or the heating current depending on which value is lower.
If you require another part number please contact with us.
※Note:
Product Presentation
MCF-1770-XXX-S2 Series
Part Number L0(uH)
Inductance (µH)@(0A)
Rdc (mΩ) @25°C
Http://www.hk-hotline.com
Item W A0 B0 K0 P F E D0 D1 P0 P2 T Packing Unit
MCW-201610 8.0±0.1 1.8±0.05 2.22±0.05 1.35±0.05 4.0±0.1 3.5±0.1 1.75±0.1 1.5±0.05 1.0±0.05 4.0±0.1 2.0±0.1 0.25±0.05 2000 Pcs
MCW-201612 8.0±0.1 1.8±0.05 2.22±0.05 1.35±0.05 4.0±0.1 3.5±0.1 1.75±0.1 1.5±0.05 1.0±0.05 4.0±0.1 2.0±0.1 0.25±0.05 2000 Pcs
MCW-252010 8.0±0.1 2.35±0.05 2.8±0.05 1.35±0.05 4.0±0.1 3.5±0.1 1.75±0.1 1.5±0.05 1.0±0.05 4.0±0.1 2.0±0.1 0.25±0.05 2000 Pcs
MCW-252012 8.0±0.1 2.35±0.05 2.8±0.05 1.35±0.05 4.0±0.1 3.5±0.1 1.75±0.1 1.5±0.05 1.0±0.05 4.0±0.1 2.0±0.1 0.25±0.05 2000 Pcs
MCW-0412 12.0±0.3 4.35±0.1 4.35±0.1 1.8±0.1 8.0±0.1 5.5±0.1 1.75±0.1 1.5±0.1 1.5±0.1 4.0±0.1 2.0±0.1 0.35±0.05 3000 Pcs
MCW-0415 12.0±0.3 4.35±0.1 4.35±0.1 1.8±0.1 8.0±0.1 5.5±0.1 1.75±0.1 1.5±0.1 1.5±0.1 4.0±0.1 2.0±0.1 0.35±0.05 3000 Pcs
MCW-0420 12.0±0.3 4.35±0.1 4.35±0.1 2.3±0.1 8.0±0.1 5.5±0.1 1.75±0.1 1.5±0.1 1.5±0.1 4.0±0.1 2.0±0.1 0.35±0.05 3000 Pcs
MCW-0512 16.0±0.3 5.4±0.1 5.4±0.1 1.8±0.1 12.0±0.1 7.5±0.1 1.75±0.1 1.5±0.1 1.5±0.1 4.0±0.1 2.0±0.1 0.35±0.05 2000 Pcs
MCW-0515 16.0±0.3 5.4±0.1 5.4±0.1 1.8±0.1 12.0±0.1 7.5±0.1 1.75±0.1 1.5±0.1 1.5±0.1 4.0±0.1 2.0±0.1 0.35±0.05 2000 Pcs
MCW-0518 16.0±0.3 5.4±0.1 5.4±0.1 2.3±0.1 12.0±0.1 7.5±0.1 1.75±0.1 1.5±0.1 1.5±0.1 4.0±0.1 2.0±0.1 0.35±0.05 1800 Pcs
MCW-0520 16.0±0.3 5.4±0.1 5.4±0.1 2.3±0.1 12.0±0.1 7.5±0.1 1.75±0.1 1.5±0.1 1.5±0.1 4.0±0.1 2.0±0.1 0.35±0.05 1500 Pcs
MCW-0530 16.0±0.3 5.4±0.1 5.4±0.1 3.3±0.1 12.0±0.1 7.5±0.1 1.75±0.1 1.5±0.1 1.5±0.1 4.0±0.1 2.0±0.1 0.35±0.05 1500 Pcs
MCW-0612 16.0±0.3 7.0±0.1 7.0±0.1 1.5±0.1 12.0±0.1 7.5±0.1 1.75±0.1 1.5±0.1 1.5±0.1 4.0±0.1 2.0±0.1 0.35±0.05 2000 Pcs
MCW-0615 16.0±0.3 7.0±0.1 7.0±0.1 1.8±0.1 12.0±0.1 7.5±0.1 1.75±0.1 1.5±0.1 1.5±0.1 4.0±0.1 2.0±0.1 0.35±0.05 2000 Pcs
MCW-0618 16.0±0.3 7.0±0.1 7.0±0.1 2.1±0.1 12.0±0.1 7.5±0.1 1.75±0.1 1.5±0.1 1.5±0.1 4.0±0.1 2.0±0.1 0.35±0.05 1800 Pcs
MCW-0620 16.0±0.3 7.0±0.1 7.0±0.1 2.3±0.1 12.0±0.1 7.5±0.1 1.75±0.1 1.5±0.1 1.5±0.1 4.0±0.1 2.0±0.1 0.35±0.05 1500 Pcs
MCW-0624 16.0±0.3 7.0±0.1 7.0±0.1 2.7±0.1 12.0±0.1 7.5±0.1 1.75±0.1 1.5±0.1 1.5±0.1 4.0±0.1 2.0±0.1 0.35±0.05 1500 Pcs
MCW-0630 16.0±0.3 7.0±0.1 7.0±0.1 3.3±0.1 12.0±0.1 7.5±0.1 1.75±0.1 1.5±0.1 1.5±0.1 4.0±0.1 2.0±0.1 0.35±0.05 1500 Pcs
MCW-0650 16.0±0.3 7.0±0.1 7.0±0.1 5.3±0.1 12.0±0.1 7.5±0.1 1.75±0.1 1.5±0.1 1.5±0.1 4.0±0.1 2.0±0.1 0.35±0.05 1000 Pcs
MCF-1030 24.0±0.3 10.5±0.1 10.5±0.1 3.3±0.1 16.0±0.1 11.5±0.1 1.75±0.1 1.5±0.1 1.5±0.1 4.0±0.1 2.0±0.1 0.35±0.05 1000 Pcs
MCF-1040 24.0±0.3 10.5±0.1 10.5±0.1 4.3±0.1 16.0±0.1 11.5±0.1 1.75±0.1 1.5±0.1 1.5±0.1 4.0±0.1 2.0±0.1 0.35±0.05 800 Pcs
MCF-1045 24.0±0.3 10.5±0.1 10.5±0.1 4.9±0.1 16.0±0.1 11.5±0.1 1.75±0.1 1.5±0.1 1.5±0.1 4.0±0.1 2.0±0.1 0.40±0.05 800 Pcs
MCF-1050 24.0±0.3 10.5±0.1 10.5±0.1 5.7±0.1 16.0±0.1 11.5±0.1 1.75±0.1 1.5±0.1 1.5±0.1 4.0±0.1 2.0±0.1 0.50±0.05 700 Pcs
MCF-1335 24.0±0.3 13.0±0.1 13.0±0.1 3.8±0.1 16.0±0.1 11.5±0.1 1.75±0.1 1.5±0.1 1.5±0.1 4.0±0.1 2.0±0.1 0.50±0.05 800 Pcs
MCF-1350 24.0±0.3 13.0±0.1 13.0±0.1 5.5±0.1 16.0±0.1 11.5±0.1 1.75±0.1 1.5±0.1 1.5±0.1 4.0±0.1 2.0±0.1 0.50±0.05 400 Pcs
MCF-1360 24.0±0.3 13.0±0.1 13.0±0.1 6.85±0.1 16.0±0.1 11.5±0.1 1.75±0.1 1.5±0.1 1.5±0.1 4.0±0.1 2.0±0.1 0.50±0.05 400 Pcs
MCF-1770 28.0±0.3 17.5±0.1 17.5±0.1 7.3±0.1 23.0±0.1 13.5±0.1 1.75±0.1 1.5±0.1 2.0±0.1 4.0±0.1 2.0±0.1 0.50±0.05 400 Pcs
These dimensions will do some adiustments needed without prior notice!
The above data will be needed to do some adjustments without prior notice!
100±1.0 13.0±1.0 12.4+2.0/-0.0
330±2.0 100±1.0 13.0±1.0 16.4+2.0/-0.0
Part NO.
MCW-05
MCW-06
※Carrier Tape Dimensions&Packing Unit
MCF-13
100±1.0 13.0±1.0
MCW-04
Dimensions of Reel
8.4+2.0/-0.0
8.4+2.0/-0.0
MCF-17
24.4+2.0/-0.0
28.4+2.0/-0.0
13.0±1.0330±2.0 100±1.0MCF-10
Packaging Specification
330±2.0 100±1.0 13.0±1.0
A B C
330±2.0
13±1.0
D
MCW-2016
MCW-2520
178±2.0
178±2.0
※ Reel Dimensions
60±1.0
60±1.0
13±1.0
16.4+2.0/-0.0
24.4+2.0/-0.0
330±2.0
330±2.0 100±1.0 13.0±1.0
Http://www.hk-hotline.com