2
fluid sensors and diagnostic systems position sensors networking and control Clear and easy operating concept with extended features for optimum use. Memory function for the highest measured system pressure. Drift-free operation for more than 100 million pressure cycles. Country-specific pressure units, selectable in bar/ mbar, kPa/ MPa, psi. Indication of the current measured values and parameter settings on the integrated 4-digit, 10-segment display. monitoring: PN5 and PN7. The standard in pressure For maximum safety and efficiency in hydraulic plants. product news Long-term stability The maximum robustness and long life ensure trouble-free and reliable operation of the pressure switches. The ce- ramic-capacitive measuring principle with a special sup- port of the measuring diaphragm makes the pressure switches immune to overload operation and high pressure peaks. Worldwide use for reduced storage For the pressure switch PN7 one menu option allows the output logic of the switching function to be changed from positive (pnp) to negative (npn) switching. For both pres- sure switches the pressure units (bar/mbar, kPa/MPa, psi) can be selected, allowing the OEM to use the same type of pressure switch regardless of the country where the ma- chine is to be installed. Transparency on site The 4-digit LED display, which is clearly visible over long distances, is indispensable for setup, maintenance and operation. The slanted display enables optimum reading from long distances and at different angles. Due to the structured menu navigation, intuitive operation is possible without any problems. The electronic lock pro- tects the unit from unauthorised access. This series is appreciated by ifm customers worldwide due to allowing quick and easy machine diagnosis. Fluid sensors and diagnostic systems

product news The standard in pressure monitoring: PN5 and PN7. · monitoring: PN5 and PN7. The standard in pressure For maximum safety and efficiency in hydraulic plants. product

  • Upload
    others

  • View
    2

  • Download
    0

Embed Size (px)

Citation preview

Page 1: product news The standard in pressure monitoring: PN5 and PN7. · monitoring: PN5 and PN7. The standard in pressure For maximum safety and efficiency in hydraulic plants. product

fluid sensorsand diagnostic

systems

positionsensors

networkingand control

Clear and easy operating concept withextended features for optimum use.

Memory function for the highestmeasured system pressure.

Drift-free operation for morethan 100 million pressure cycles.

Country-specific pressure units,selectable in bar/mbar, kPa/MPa, psi.

Indication of the current measuredvalues and parameter settings on the

integrated 4-digit, 10-segment display.

monitoring: PN5 and PN7.The standard in pressure

For maximum safety andefficiency in hydraulic plants.

product news

Long-term stabilityThe maximum robustness and long life ensure trouble-freeand reliable operation of the pressure switches. The ce-ramic-capacitive measuring principle with a special sup-port of the measuring diaphragm makes the pressureswitches immune to overload operation and high pressurepeaks.

Worldwide use for reduced storageFor the pressure switch PN7 one menu option allows theoutput logic of the switching function to be changed frompositive (pnp) to negative (npn) switching. For both pres-sure switches the pressure units (bar /mbar, kPa/MPa, psi)can be selected, allowing the OEM to use the same type ofpressure switch regardless of the country where the ma-chine is to be installed.

Transparency on siteThe 4-digit LED display, which is clearly visible over longdistances, is indispensable for setup, maintenance andoperation. The slanted display enables optimum readingfrom long distances and at different angles.Due to the structured menu navigation, intuitive operationis possible without any problems. The electronic lock pro-tects the unit from unauthorised access. This series isappreciated by ifm customers worldwide due to allowingquick and easy machine diagnosis.

Flu

id s

enso

rs a

nd

dia

gn

ost

ic s

yste

ms

Page 2: product news The standard in pressure monitoring: PN5 and PN7. · monitoring: PN5 and PN7. The standard in pressure For maximum safety and efficiency in hydraulic plants. product

Output 1

Output 2 (only PN7...)

PN7009 PN7007

PN5007

PN7006

PN5006

PN7004

PN5004

PN7003

PN5003

PN7002

PN5002

PN7001

PN5001

PN7000

PN5000

PN7060

Order no.

Perm. overload pressure [bar]

Min. bursting pressure [bar]

Measuring range [bar] -1...1 0...1 0...2.5 0...10 0...25 0...100 0...250 0...400 0...600

10

30

10

30

20

50

75

150

150

350

300

650

400

850

600

1000

800

1200

switching output 1

switching output 2

Insulation resistance [MΩ]

Materials (wetted parts)

Housing materials

Shock resistance [g]

Vibration resistance [g]

Pressure cycles min.

Operating voltage [V]

Current consumption [mA]

Current rating [mA]

Medium temperature [°C]

Operating temperature [°C]

Wiring diagram PN5...

Wiring diagram PN7...

E10908

5 m (PUR), M12 angled, without LED

10 m (PUR), M12 angled, without LED

5 m (PUR), M12 straight, without LED

10 m (PUR), M12 straight, without LED

E10901

E10902

E10907

E30006

ifm

ifm

ifm

ifm

Protective cover

>100 (500 V DC)

stainless steel (303S21), ceramics, FPM (Viton)

stainless steel (303S21), high-grade stainless steel (316S12), EPDM/X, FPM, PC, PBTP, PEI, *

50 (DIN / IEC 68-2-27, 11 ms)

20 (DIN / IEC 68-2-6, 10-2000 Hz)

100 million

18...36 DC

< 50

250

-25...80

-25...80

E30078Fixture for 2 sensors

E30079Fixture for 3 sensors

R

Stainless steel housing, IP 67, G 1/4 I4-digit 10-segment LED displayGases up to 25 bar

91,5

34

27

10-segmentdisplay programming button

1,3

21,5

30

48

57,3

M12

x1

13,5

G

1 switching output (PN5...)2 switching outputs (PN7...) NPN/PNP selectableMeasuring range up to 600 bar

DimensionsSockets

Sockettype Order no.Design

Application Gases (up to max. 25 bar) and liquids

Electrical design

Connection

DCPN5: 3-wire, PN7: 4-wire

Example PN5002

Accessories

Description Order no.

Hno Hnc

L+

L

1

4

3

4

L

L+

2

1

34: OUT 12: OUT 2

4

L

L+

2

1

34: OUT 12: OUT 2

Visit our website: www.ifm-electronic.comWe

rese

rve

the

right

to

mak

e te

chni

cal a

ltera

tions

with

out

prio

r no

tice.

Prin

ted

in G

erm

any

on n

on-c

hlor

ine

blea

ched

pap

er. K

E129

/200

4Fl

uid

sen

sors

an

d d

iag

no

stic

sys

tem

s

Pressure sensors

*measuring range up to 25 bar, additionally PTFE