2
Product Information Features Benefits Thermosetting, reactive sealant Excellent structural integrity of sealed unit Chemical resistant sealant Reduced unit failures due to incompatible glazing environments compared to silicone secondary-sealed IG Low moisture vapor transmission rate (MVTR) Longer life expectancy for IG units Superior slump resistance Cleaner, easier applying sealant. Less waste in hand applied applications Solvent free formulation Utilized for single-seal units* P.O. Box 457, 4401 Page Avenue Michigan Center, MI 49254 Phone: (800) 248-4010 Fax: (517) 764-6697 www.adcocorp.com CAUTION: All statements and technical information in this document are based on tests or data that ADCO believes is reliable. However, ADCO does not warrant or guarantee the accuracy or completeness of this information. The user has sole knowledge and control offactors that can affect the performance of ADCO’s products in the user’s intended application. It is the user’s responsibility to conduct tests to determine the compatibility of ADCO’s product with the design, structure, and materials of the user’s end product and the suitability of ADCO’s product for the user’s method of application and intended use. The user assumes all risk and liability arising out of such use. Packaging Kommerling GD 116 is available in the following standard packages: Part # IG-0116-DR IG-0B65-PA IG-0B65-DR IG-0B20-PA IG-0B20-DR Package Drum Pail Drum Pail Drum Storage and Shelf Life Store material in original unopened packaging at temperatures between 40°F-100°F. Shelf life is 12 months when stored as recommended. Fill Volume 50 gallon 5 gallon 55 gallon 5 gallon 55 Gallon Description Part A Part B-Std Cure Part B-Std Cure Part B-Fast Cure Part B-Fast Cure ll ll * It is the individual IG manufacturer’s responsibility to determine if this product is suitable for single-seal units. Kommerling GD 116 LP Polysulfide Insulating Glass Sealant Description Kommerling GD 116 is a 2-component, solvent-free, liquid polymer (LP) polysulfide sealant. Kommerling GD 116 demonstrates high strength and elasticity, and is a lower odor polysulfide. It has excellent adhesion to clean surfaces such as glass, aluminum, galvanized and stainless steel. Basic Use Kommerling GD 116 is designed to be used as a secondary edge sealant for dual-seal insulating glass units and is widely used in the manufacture of high-end wood windows. Kommerling GD 116 demonstrates excellent adhesion to glass surfaces and most IG spacer systems including aluminum, anodized aluminum, stainless steel, and tin plated steel. It has been formulated to work in hand-gunning as well as fully automated robotic application. Kommerling GD 116 is resistant to oils, solvents, and a wide-array of chemicals and thus provides excellent protection against IG unit failure caused by incompatibility with glazing materials. Due to it’s impermeability to most solvents, oils, and plasticizers, Kommerling GD 116 is particularly suited for application with non-rigid warm-edge spacer systems such as TPS®, pre-extruded butyl spacers, or foam based spacer systems. Kommerling GD 116 is compatible with all commercially available PIB based primary sealants. Typical application rates are a minimum 4.0mm depth for gas-filled IG units. (However, when determining sealant volume, unit size, weight, and glazing system design need to be evaluated for proper IG assembly design.) Limitations • High- viscosity Kommerling GD 116 requires a Graco Hydra-Mate equipped with King air motor. Graco Bulldog® motors normally do not pump a sufficient volume of Kommerling GD 116 for high-volume production. Kommerling GD 116 pumps very well on all European IG application equipment. • IG produced with Kommerling GD 116 or any LP Polysulfide should not be used for direct glazing (curtain wall) applications or in applications where the sealant is exposed to direct UV light. Kommerling GD 116 is intended for framed insulating glass applications. ll ll ll ll ll ll ll ll ll ll ll ll ll

Product Information - ADCO : Adhesives, Sealants, · PDF fileProduct Information Features Benefits ... application with non-rigid warm-edge spacer systems such as ... Bystronic manual

Embed Size (px)

Citation preview

Page 1: Product Information - ADCO : Adhesives, Sealants, · PDF fileProduct Information Features Benefits ... application with non-rigid warm-edge spacer systems such as ... Bystronic manual

Product Information

Features BenefitsThermosetting, reactive sealant Excellent structural integrity

of sealed unit

Chemical resistant sealant Reduced unit failures due to incompatible glazing environments compared to silicone secondary-sealed IG

Low moisture vapor transmission rate (MVTR)

Longer life expectancy for IG units

Superior slump resistance Cleaner, easier applying sealant. Less waste in hand applied applications

Solvent free formulation Utilized for single-seal units*

P.O. Box 457, 4401 Page Avenue Michigan Center, MI 49254 Phone: (800) 248-4010 Fax: (517) 764-6697 www.adcocorp.com

CAUTION: All statements and technical information in this document are based on tests or data that ADCO believes is reliable. However, ADCO does not warrant or guarantee the accuracy or completeness of this information. The user has sole knowledge and control offactors that can affect the performance of ADCO’s products in the user’s intended application. It is the user’s responsibility to conduct tests to determine the compatibility of ADCO’s product with the design, structure, and materials of the user’s end product and the suitability of ADCO’s product for the user’s method of application and intended use. The user assumes all risk and liability arising out of such use.

PackagingKommerling GD 116 is available in the following standard packages:

Part #

IG-0116-DRIG-0B65-PAIG-0B65-DRIG-0B20-PAIG-0B20-DR

Package

DrumPailDrumPailDrum

Storage and Shelf LifeStore material in original unopened packaging at temperatures between 40°F-100°F. Shelf life is 12 months when stored as recommended.

Fill Volume

50 gallon5 gallon55 gallon5 gallon55 Gallon

Description

Part APart B-Std CurePart B-Std CurePart B-Fast CurePart B-Fast Cure

ll

ll

* It is the individual IG manufacturer’s responsibility to determine if this product is suitable for single-seal units.

Kommerling GD 116LP Polysulfide Insulating Glass SealantDescriptionKommerling GD 116 is a 2-component, solvent-free, liquid polymer (LP) polysulfide sealant. Kommerling GD 116 demonstrates high strength and elasticity, and is a lower odor polysulfide. It has excellent adhesion to clean surfaces such as glass, aluminum, galvanized and stainless steel.

Basic UseKommerling GD 116 is designed to be used as a secondary edge sealant for dual-seal insulating glass units and is widely used in the manufacture of high-end wood windows. Kommerling GD 116 demonstrates excellent adhesion to glass surfaces and most IG spacer systems including aluminum, anodized aluminum, stainless steel, and tin plated steel. It has been formulated to work in hand-gunning as well as fully automated robotic application.

Kommerling GD 116 is resistant to oils, solvents, and a wide-array of chemicals and thus provides excellent protection against IG unit failure caused by incompatibility with glazing materials. Due to it’s impermeability to most solvents, oils, and plasticizers, Kommerling GD 116 is particularly suited for application with non-rigid warm-edge spacer systems such as TPS®, pre-extruded butyl spacers, or foam based spacer systems. Kommerling GD 116 is compatible with all commercially available PIB based primary sealants.

Typical application rates are a minimum 4.0mm depth for gas-filled IG units. (However, when determining sealant volume, unit size, weight, and glazing system design need to be evaluated for proper IG assembly design.)

Limitations• High- viscosity Kommerling GD 116 requires a Graco Hydra-Mate equipped with King air motor. Graco Bulldog® motors normally do not pump a sufficient volume of Kommerling GD 116 for high-volume production. Kommerling GD 116 pumps very well on all European IG application equipment.• IG produced with Kommerling GD 116 or any LP Polysulfide should not be used for direct glazing (curtain wall) applications or in applications where the sealant is exposed to direct UV light. Kommerling GD 116 is intended for framed insulating glass applications.

ll

ll

ll

ll

ll

ll

ll

ll

ll

ll

ll

ll

ll

Page 2: Product Information - ADCO : Adhesives, Sealants, · PDF fileProduct Information Features Benefits ... application with non-rigid warm-edge spacer systems such as ... Bystronic manual

Glazing CompatibilityIt is recommended that glazing materials be tested for compatibility and that all units be glazed in accordance with GANA (Glass Association of North America) and IGMA (Insulating Glass Manufacturers Alliance) recommenda-tions. Contact with any solvent, oil, or plasticizer-contain-ing glazing materials should be avoided.

Technical DataPerformance Properties

Typical Values Test MethodDensityPart APart B

1.75 - 1.81 g/ml1.53 - 1.59 g/ml

73oF + 2

Pot LifeB 20B 65

15 - 30 minutes55 - 80 minutes

73oF + 2

Moisture Vapor Transmission Rate

4 - 6 g/m2/24 hr DIN 53122 Part 1Climate D; 3mm film

Shore A Hardness 37 - 45 DIN 53505; Cure time of 24 hours at 73oF + 2, 50% RH

Peel Strength > 5 N/mm> 28 lb/in

Cure time of 24 hours at 73oF + 2, 50% RH, 90o peel angle at a rate of 100mm/ minute

Tear Strength 0.9 - 1.3 N/mm2

130 - 188 lb/in2

Cure time of 7 days at 73oF + 2, 50% RH, DIN 52455 Part 1

Physical PropertiesComposition:Part A BasePart B Hardener (B65 or B20)

LP PolysulfideManganese Dioxide

Color Black

WARRANTY: ADCO warrants its products to conform to ADCO’s specifications at the time of sale when tested according to ADCO standards. If a product is proven to be defective when tested according to ADCO standards, ADCO will, at its option, refund the purchase price or replace or repair the defective product. THIS LIMITED WARRANTY IS THE BUYERS SOLE AND EXCLUSIVE REMEDY AGAINST ADCO AND IS IN LIEU OF ANY AND ALL OTHER WARRANTIES, EXPRESS OR IMPLIED, INCLUDING, BUT NOT LIMITED TO, ANY IMPLIED WARRANTY OF MERCHANTIBILITY OR FITNESS FOR A PARTICULAR PURPOSE. In no event shall ADCO be liable for any special, incidental, consequen-tial, or punitive damages arising out of any claims whether based on negligence, contract, warranty, strict liability or otherwise.

XXXXX • 09/2009

P.O. Box 457, 4401 Page Avenue Michigan Center, MI 49254 Phone: (800) 248-4010 Fax: (517) 764-6697 www.adcocorp.com

NOTE:The foregoing information is published as general information only. The listed properties and performance characteristics are typical values and are not to be interpreted as manufacturing specifications.

SafetyPrior to working with this or any product consult product label and Material Safety Data Sheet (MSDS) for necessary health and safety precautions.

ApplicationSubstrate Preparation: The surfaces to be bonded must be dry, clean and free from dust and grease. Glass surfaces should be thoroughly cleaned by hand or machine with non-film forming, low residue detergent and rinsed thoroughly with clean hot water.

Blending: When using automatic mixers observe the correct setting of the dosing cylinder. The mixing ratio according to volume is 10:1. The two- component mixture must be applied within approximately 20 minutes (pot life at 23oC / 73oF). Prepare only the amount that can be applied within this period of time. As temperature increases, pot life decreases. General pot life date for B20 is as follows:20 minute pot life at 20oC (68oF) material temperature10 minute pot life at 30oC (86oF) material temperature5 minute pot life at 40oC (104oF) material temperature

Important: if mixing ratio is over-catalyzed in excess of 10:1.1 by volume, poor mechanical properties may result. If mixing ratio is under-catalyzed in excess of 10:0.8 by volume, the final product properties will be only slightly affected. However, the pot-life will be altered in both instances.

Curing: Kommerling GD 116 should not be applied below 10oC (50oF). The curing speed of Kommerling GD 116 depends on the ambient temperature.• At 50oC (40oF) the curing times can triple.• At 30oC (860F) curing times are shortened by 50%.• A tack free surface is reached after ~ 1 - 2 hours with the B65 hardener at 23oC (73oF) and ~ 15 - 25 minutes with B20.

Newly fabricated insulating glass units must not be exposed to low temperatures or rain until the desiccant has been able to sufficiently dry the air space to prevent condensation on the glass panes. After 3 hours of pre-drying, the risk is minimal.

Clean Up: Citrus based solvents can be used to clean tools and equipment immediately after use to remove fresh uncured material.

Equipment: The following equipment is suitable for applying Kommerling GD 116: GRACO Hydra-Mate Shovel Pumps equipped with King Air motors, Reinhardt Technik Pumps, Schwartz, and Lisec & Bystronic manual and semi-automated lines.

ll

ll

ll