Set sensor parameters alternatively numerically using LED-display...
T2T1
T2 T2T1
T1 + T2
Set detect distance inmm or cm
For single detectpoint press T2until »- - -« is displayed
Choose » « for NCC or » « for NOC
T1 T2
For window mode operation set far detect point in mm or cm
T1 + T2
Press T1 and T2 simultaneously for about3 s until welcome message has passed
T1 + T2
T2T1
T1 + T2
T1 + T2
T1 + T2
T2 T1
T2T1
T2 T2T1
T1 + T2
Set detect distance inmm or cm
Choose » « for NCC or » « for NOC
T1 T2
T1 + T2
T2T1
T1 + T2
T1 + T2
Set switched output D1 Set switched output D2
For single detectpoint press T2until »- - -« is displayed
For window mode operation set far detect point in mm or cm
Ready
Start here
Product descriptionThe crm+sensor with with two switchedoutputs measures the distance to an ob-ject within the detection zone contactless.Depending on the adjusted detect distan-ce the switched outputs are set.The ultrasonic transducer surface of thecrm+sensors is laminated with a PEEKfilm. The transducer itself is sealedagainst the housing by a PTFE joint ring.This composition ensures a high resitanceagainst many aggressive substances.All settings are done with two push-but-tons and a three-digit LED-display(TouchControl).Light emitting diodes (three-colour LEDs)indicate the switching status.The output functions are changeablefrom NOC to NCC. The sensors are adjustable manually usingthe numerical LED-display or may be trai-ned using Teach-in processes.Useful additional functions are set in theAdd-on-menu.Using the LinkControl adapter (optionalaccessory) all TouchControl and additio-nal sensor parameter settings may bemade by a Windows-Software.
Safety NotesRead the operating instructions prior tostart-up.Connection, installation and adjustmentworks may only be carried out by expertpersonnel.No safety component in accordance withthe EU Machine Directive.
The crm+ sensors indicate a blind zone, inwhich the distance cannot be measured. Theoperating range indicates the distance of thesensor that can be applied with normal re-flectors with sufficient function reserve.When using good reflectors, such as a calmwater surface, the sensor can also be used upto its maximum range. Objects that stronglyabsorb (e.g. plastic foam) or diffusely reflectsound (e.g. pebble stones) can also reducethe defined operating range.
SynchronisationIf the assembly distances shown in Fig.1 fortwo or more sensors are exceeded the inte-grated synchronisation should be used. Con-nect Sync/Com-channels (pin 5 at the units re-ceptable) of all sensors (10 maximum).
Fig. 1: Assembly distances, indicating syn-chronisation/multiplex
Multiplex modeThe Add-on-menu allows to assign an indivi-dual address »01« to »10« to each sensorconnected via the Sync/Com-channel (Pin5).The sensors perform the ultrasonic measure-ment sequentially from low to high address.Therefore any influence between the sensorsis rejected. The address »00« is reserved to synchronisa-tion mode and deactivates the multiplexmode. (To use synchronised mode all sensorsmust be set to address »00«.)
≥0.35 m≥0.40 m
≥2.50 m≥2.50 m
≥1.10 m≥2.00 m
≥8.00 m≥18.00 m
≥4.00 m ≥30.00 m
Assembly instructionsAssemble the sensor at the installation lo-cation.Plug in the connector cable to the M 12connector.
Fig. 2: Pin assignment with view onto sensorplug and colour coding of the microsonic connection cable
Start-upcrm+ sensors are delivered factory made withthe following settings:
Switched output on NOCDetecting distance at operating rangeand half operating rangeMeasurement range set to maximum ran-ge
13
colour
+UB
-UB
brownblue
425
D2D1
blackwhite
Sync/Com. grey
1
5
2
3 4
Set the parameters of the sensor manually oruse the Teach-in procedure to adjust the de-tect points.
Fig. 3: TouchControl
Operationcrm+sensors work maintenance free. Smallamounts of dirt on the surface do not influ-ence function. Thick layers of dirt and caked-on dirt affect sensor function and thereforemust be removed.
NoteAs a result of the design the assembly ofPEEK film and PTFE joint ring is not gas-proof.The chemical resistance has to be testedexperimentally if necessary.crm+ensors have internal temperaturecompensation. Because the sensors heatup on their own, the temperature com-pensation reaches its optimum workingpoint after approx. 30 minutes of operati-on.During normal mode operation, a yellowLED D2 signals that the switched outputhas connected.During normal mode operation, the mea-sured distance value is displayed on theLED-indicator in mm (up to 999 mm) orcm (from 100 cm). Scale switches auto-matically and is indicated by a point ontop of the digits.During Teach-in mode, the hysteresisloops are set back to factory settings.If no objects are placed within the detec-tion zone the LED-indicator shows »- - -«.If no push-buttons are pressed for 20 se-conds during parameter setting mode themade changes are stored and the sensorreturns to normal mode operation.You can lock the key pad to provide in-puts, see »Key lock and factory setting«.You can reset the factory settings at anytime, see »Key lock and factory setting«.
Show parametersTapping push-button T1 shortly during nor-mal mode operation shows »PAr« on theLED-display. Each time you tap push-buttonT1 the actual settings of the switched outputare shown.
Operating manualcrm+ Ultrasonic Sensors withtwo switched outputs
c m m m %
T 1 D 1 D 2 T 2
measuring range
LED D1 and D2
3-digit LED-display
Push-buttons T1 and T2
crm+25/DD/TC/Ecrm+35/DD/TC/Ecrm+130/DD/TC/Ecrm+340/DD/TC/Ecrm+600/DD/TC/E
2014/30/EU
SENSORPARTNERS.COM
Set sensor parameters alternatively numerically using LED-display...
T2T1
T2 T2T1
T1 + T2
Set detect distance inmm or cm
For single detectpoint press T2until »- - -« is displayed
Choose » « for NCC or » « for NOC
T1 T2
For window mode operation set far detect point in mm or cm
T1 + T2
Press T1 and T2 simultaneously for about3 s until welcome message has passed
T1 + T2
T2T1
T1 + T2
T1 + T2
T1 + T2
T2 T1
T2T1
T2 T2T1
T1 + T2
Set detect distance inmm or cm
Choose » « for NCC or » « for NOC
T1 T2
T1 + T2
T2T1
T1 + T2
T1 + T2
Set switched output D1 Set switched output D2
For single detectpoint press T2until »- - -« is displayed
For window mode operation set far detect point in mm or cm
Ready
Start here
Product descriptionThe crm+sensor with with two switchedoutputs measures the distance to an ob-ject within the detection zone contactless.Depending on the adjusted detect distan-ce the switched outputs are set.The ultrasonic transducer surface of thecrm+sensors is laminated with a PEEKfilm. The transducer itself is sealedagainst the housing by a PTFE joint ring.This composition ensures a high resitanceagainst many aggressive substances.All settings are done with two push-but-tons and a three-digit LED-display(TouchControl).Light emitting diodes (three-colour LEDs)indicate the switching status.The output functions are changeablefrom NOC to NCC. The sensors are adjustable manually usingthe numerical LED-display or may be trai-ned using Teach-in processes.Useful additional functions are set in theAdd-on-menu.Using the LinkControl adapter (optionalaccessory) all TouchControl and additio-nal sensor parameter settings may bemade by a Windows-Software.
Safety NotesRead the operating instructions prior tostart-up.Connection, installation and adjustmentworks may only be carried out by expertpersonnel.No safety component in accordance withthe EU Machine Directive.
The crm+ sensors indicate a blind zone, inwhich the distance cannot be measured. Theoperating range indicates the distance of thesensor that can be applied with normal re-flectors with sufficient function reserve.When using good reflectors, such as a calmwater surface, the sensor can also be used upto its maximum range. Objects that stronglyabsorb (e.g. plastic foam) or diffusely reflectsound (e.g. pebble stones) can also reducethe defined operating range.
SynchronisationIf the assembly distances shown in Fig.1 fortwo or more sensors are exceeded the inte-grated synchronisation should be used. Con-nect Sync/Com-channels (pin 5 at the units re-ceptable) of all sensors (10 maximum).
Fig. 1: Assembly distances, indicating syn-chronisation/multiplex
Multiplex modeThe Add-on-menu allows to assign an indivi-dual address »01« to »10« to each sensorconnected via the Sync/Com-channel (Pin5).The sensors perform the ultrasonic measure-ment sequentially from low to high address.Therefore any influence between the sensorsis rejected. The address »00« is reserved to synchronisa-tion mode and deactivates the multiplexmode. (To use synchronised mode all sensorsmust be set to address »00«.)
≥0.35 m≥0.40 m
≥2.50 m≥2.50 m
≥1.10 m≥2.00 m
≥8.00 m≥18.00 m
≥4.00 m ≥30.00 m
Assembly instructionsAssemble the sensor at the installation lo-cation.Plug in the connector cable to the M 12connector.
Fig. 2: Pin assignment with view onto sensorplug and colour coding of the microsonic connection cable
Start-upcrm+ sensors are delivered factory made withthe following settings:
Switched output on NOCDetecting distance at operating rangeand half operating rangeMeasurement range set to maximum ran-ge
13
colour
+UB
-UB
brownblue
425
D2D1
blackwhite
Sync/Com. grey
1
5
2
3 4
Set the parameters of the sensor manually oruse the Teach-in procedure to adjust the de-tect points.
Fig. 3: TouchControl
Operationcrm+sensors work maintenance free. Smallamounts of dirt on the surface do not influ-ence function. Thick layers of dirt and caked-on dirt affect sensor function and thereforemust be removed.
NoteAs a result of the design the assembly ofPEEK film and PTFE joint ring is not gas-proof.The chemical resistance has to be testedexperimentally if necessary.crm+ensors have internal temperaturecompensation. Because the sensors heatup on their own, the temperature com-pensation reaches its optimum workingpoint after approx. 30 minutes of operati-on.During normal mode operation, a yellowLED D2 signals that the switched outputhas connected.During normal mode operation, the mea-sured distance value is displayed on theLED-indicator in mm (up to 999 mm) orcm (from 100 cm). Scale switches auto-matically and is indicated by a point ontop of the digits.During Teach-in mode, the hysteresisloops are set back to factory settings.If no objects are placed within the detec-tion zone the LED-indicator shows »- - -«.If no push-buttons are pressed for 20 se-conds during parameter setting mode themade changes are stored and the sensorreturns to normal mode operation.You can lock the key pad to provide in-puts, see »Key lock and factory setting«.You can reset the factory settings at anytime, see »Key lock and factory setting«.
Show parametersTapping push-button T1 shortly during nor-mal mode operation shows »PAr« on theLED-display. Each time you tap push-buttonT1 the actual settings of the switched outputare shown.
Operating manualcrm+ Ultrasonic Sensors withtwo switched outputs
c m m m %
T 1 D 1 D 2 T 2
measuring range
LED D1 and D2
3-digit LED-display
Push-buttons T1 and T2
crm+25/DD/TC/Ecrm+35/DD/TC/Ecrm+130/DD/TC/Ecrm+340/DD/TC/Ecrm+600/DD/TC/E
2014/30/EU
Set sensor parameters alternatively numerically using LED-display...
T2T1
T2 T2T1
T1 + T2
Set detect distance inmm or cm
For single detectpoint press T2until »- - -« is displayed
Choose » « for NCC or » « for NOC
T1 T2
For window mode operation set far detect point in mm or cm
T1 + T2
Press T1 and T2 simultaneously for about3 s until welcome message has passed
T1 + T2
T2T1
T1 + T2
T1 + T2
T1 + T2
T2 T1
T2T1
T2 T2T1
T1 + T2
Set detect distance inmm or cm
Choose » « for NCC or » « for NOC
T1 T2
T1 + T2
T2T1
T1 + T2
T1 + T2
Set switched output D1 Set switched output D2
For single detectpoint press T2until »- - -« is displayed
For window mode operation set far detect point in mm or cm
Ready
Start here
Product descriptionThe crm+sensor with with two switchedoutputs measures the distance to an ob-ject within the detection zone contactless.Depending on the adjusted detect distan-ce the switched outputs are set.The ultrasonic transducer surface of thecrm+sensors is laminated with a PEEKfilm. The transducer itself is sealedagainst the housing by a PTFE joint ring.This composition ensures a high resitanceagainst many aggressive substances.All settings are done with two push-but-tons and a three-digit LED-display(TouchControl).Light emitting diodes (three-colour LEDs)indicate the switching status.The output functions are changeablefrom NOC to NCC. The sensors are adjustable manually usingthe numerical LED-display or may be trai-ned using Teach-in processes.Useful additional functions are set in theAdd-on-menu.Using the LinkControl adapter (optionalaccessory) all TouchControl and additio-nal sensor parameter settings may bemade by a Windows-Software.
Safety NotesRead the operating instructions prior tostart-up.Connection, installation and adjustmentworks may only be carried out by expertpersonnel.No safety component in accordance withthe EU Machine Directive.
The crm+ sensors indicate a blind zone, inwhich the distance cannot be measured. Theoperating range indicates the distance of thesensor that can be applied with normal re-flectors with sufficient function reserve.When using good reflectors, such as a calmwater surface, the sensor can also be used upto its maximum range. Objects that stronglyabsorb (e.g. plastic foam) or diffusely reflectsound (e.g. pebble stones) can also reducethe defined operating range.
SynchronisationIf the assembly distances shown in Fig.1 fortwo or more sensors are exceeded the inte-grated synchronisation should be used. Con-nect Sync/Com-channels (pin 5 at the units re-ceptable) of all sensors (10 maximum).
Fig. 1: Assembly distances, indicating syn-chronisation/multiplex
Multiplex modeThe Add-on-menu allows to assign an indivi-dual address »01« to »10« to each sensorconnected via the Sync/Com-channel (Pin5).The sensors perform the ultrasonic measure-ment sequentially from low to high address.Therefore any influence between the sensorsis rejected. The address »00« is reserved to synchronisa-tion mode and deactivates the multiplexmode. (To use synchronised mode all sensorsmust be set to address »00«.)
≥0.35 m≥0.40 m
≥2.50 m≥2.50 m
≥1.10 m≥2.00 m
≥8.00 m≥18.00 m
≥4.00 m ≥30.00 m
Assembly instructionsAssemble the sensor at the installation lo-cation.Plug in the connector cable to the M 12connector.
Fig. 2: Pin assignment with view onto sensorplug and colour coding of the microsonic connection cable
Start-upcrm+ sensors are delivered factory made withthe following settings:
Switched output on NOCDetecting distance at operating rangeand half operating rangeMeasurement range set to maximum ran-ge
13
colour
+UB
-UB
brownblue
425
D2D1
blackwhite
Sync/Com. grey
1
5
2
3 4
Set the parameters of the sensor manually oruse the Teach-in procedure to adjust the de-tect points.
Fig. 3: TouchControl
Operationcrm+sensors work maintenance free. Smallamounts of dirt on the surface do not influ-ence function. Thick layers of dirt and caked-on dirt affect sensor function and thereforemust be removed.
NoteAs a result of the design the assembly ofPEEK film and PTFE joint ring is not gas-proof.The chemical resistance has to be testedexperimentally if necessary.crm+ensors have internal temperaturecompensation. Because the sensors heatup on their own, the temperature com-pensation reaches its optimum workingpoint after approx. 30 minutes of operati-on.During normal mode operation, a yellowLED D2 signals that the switched outputhas connected.During normal mode operation, the mea-sured distance value is displayed on theLED-indicator in mm (up to 999 mm) orcm (from 100 cm). Scale switches auto-matically and is indicated by a point ontop of the digits.During Teach-in mode, the hysteresisloops are set back to factory settings.If no objects are placed within the detec-tion zone the LED-indicator shows »- - -«.If no push-buttons are pressed for 20 se-conds during parameter setting mode themade changes are stored and the sensorreturns to normal mode operation.You can lock the key pad to provide in-puts, see »Key lock and factory setting«.You can reset the factory settings at anytime, see »Key lock and factory setting«.
Show parametersTapping push-button T1 shortly during nor-mal mode operation shows »PAr« on theLED-display. Each time you tap push-buttonT1 the actual settings of the switched outputare shown.
Operating manualcrm+ Ultrasonic Sensors withtwo switched outputs
c m m m %
T 1 D 1 D 2 T 2
measuring range
LED D1 and D2
3-digit LED-display
Push-buttons T1 and T2
crm+25/DD/TC/Ecrm+35/DD/TC/Ecrm+130/DD/TC/Ecrm+340/DD/TC/Ecrm+600/DD/TC/E
2014/30/EU
+32 (0)2 - 464 96 90
sensorpartners.com
Z.1 Researchpark 310
B-1731, Zellik
Belgium
Sensor Partners BVBA
+31 (0)416 - 37 82 39
sensorpartners.com
James Wattlaan 15
5151 DP Drunen
The Netherlands
Sensor Partners BV
Contact
...or with the Teach-in procedure
Adjust detect point D1
Place object at position
Press T1 until »d« is shown
Current measu-ring value
Press T1 until »End« is shown
Adjust window mode D1
Place object at position
Press T1 until »d« is shown
Place object at position
Current measu-ring value
Press T1 until »End« is shown
Current measu-ring value
Adjust two-way reflectiv barrier D1
Place reflector at position
Set NOC/NCC D1 Adjust detect point D2
Place object at position
Press T1 until »d« is shown
Current measu-ring value
Press T1 until countdownpassed from »- 8 -« to »- 0 -«and NOC or NCC symbol is
displayed
Press T1 until countdownpassed from »- 8 -« to »- 0 -«
and »End« is displayed
To change output functionpress T1
Press T1 and T2 simultaneous-ly until »End« is displayed
Symbol NOC or NCC
Press T2 until »d« is shown
Current measu-ring value
Symbol NOC or NCC
Press T2 until »End« is shown
Adjust window mode D2
Place object at position
Adjust two-way reflectiv barrier D2
Place reflector at position
Set NOC/NCC D2
Press T2 until »d« is shown
Place object at position
Current measu-ring value
Press T2 until »End« is shown
Current measu-ring value
Press T2 until »d« is shown
Current measu-ring value
Press T2 until countdownpassed from »- 8 -« to »- 0 -«and NOC or NCC symbol is
displayed
Press T2 until countdownpassed from »- 8 -« to »- 0 -«
and »End« is displayed
To change output functionpress T2
Press T1 and T2 simultaneous-ly until »End« is displayed
Symbol NOC or NCC
Symbol NOC or NCC
Normal mode operation Normal mode operation
Usefull additional functions in Add-on menu (for experienced users only, settings not required for standard applications)
T1 + T2
T1 T2
T1 + T2
Press T1 and T2 simultaneously for about 13 suntil »Add« is shown in the LED-display
T1 + T2
T2T1
Start here
T2 T1
T1 + T2
Ready»C01«: Displaybright
»C02«: Display dim-med
»C03«: Display off
To optimize multi-plex speed the hig-hest sensor addressmay be set.
Setting range »01«to »10«
»F00«: no filter
»F01«: standard fil-ter
»F02«: averaging fil-ter
»F03«: foregroundfilter
»F04«: background filter
Defines the strengthof the chosen filter.
»P00«: weak filterup to
»P09«: strong filter
Affects the size ofthe detection zone.
»E01«: high
»E02«: standard
»E03«: slight
Minimum value:blind zone
Maximum value: ne-arwindow limit - 1
Low power mode Measurement filter Filter strength Foreground suppression
Multiplex mode device addressing
Multiplex modehighest address
»00«: synchronisati-on
»01« to »10«: sensoraddress for multi-plex mode
»oFF«: synchronisati-on deactivated
Minimum value: sen-sor-distant windowmargin
Maximum value: 999mm for crm+25/...and crm+35/... and999 cm for all othertypes
Measurement range Calibrationdisplay
Detection zonesensitivity
Put plane reflectorvertically disposed infront of sensor: inan exact distance of250 mm for crm+25/... and crm+35/...and 900 mm for allother types.Adjust display to250 mm or 900 mm.Confirm calibrationwith T1 + T2.
T1 + T2
T1 T2
T1 + T2
T2T1
T1 + T2
T1 T2
T1 + T2
T2T1
T1 + T2
T1 T2
T1 + T2
T2T1
T1 + T2
T1 T2
T1 + T2
T2T1
T1 + T2
T1 T2
T1 + T2
T2T1
T1 + T2
T1 T2
T1 + T2
T2T1
T1 + T2
T1 T2
T1 + T2
T2T1
T1 + T2
T1 T2
T1 + T2
T2T1
Delay in secondsbetween the detec-tion of an objectand the output ofthe measured dis-tance in case of ob-ject approach (beha-ves as on-delay).
"00": 0 s (no delay)up to
"20": 20 s responsetime
Response time
T1 + T2
T1 T2
T1 + T2
T2T1
Note Changes in the Add-onmenu may impair thesensor function. A6, A7, A8 , A10 , A11,A12 have influence onthe response time ofthe sensor.
Hysteresis switched output D1
Minimum value:»001«
Maximum value: dif-ference betweenmaximum range anddetect point - 1
During windowmode operation hys-teresis influencesboth detect points.
T1 + T2
T1 T2
T1 + T2
T2T1
Hysteresis switched output D2
Minimum value:»001«
Maximum value: dif-ference betweenmaximum range anddetect point - 1
During windowmode operation hys-teresis influencesboth detect points.
T1 + T2
T1 T2
T1 + T2
T2T1
Teach-in swítched output D1
Key lock and factory setting
Activate/deactivateTouchControl
Reset to factory set-ting
Turn supply voltageOFF
While pressing T1 turnsupply voltage ON
until »on« or »off« isdisplayed
Turn supply voltageOFF
While pressing T1 turnsupply voltage ON forca. 15 s until «rESET»has past through the
display
To activate or deactivate press T1
»on« or»off«
To activate or deactivate press T1
»on« or»off«
Normal mode operationTeach-in swítched output D2
SENSORPARTNERS.COM
SENSORPARTNERS.COM
*B7885* MV-DO-095977-508087
Technical data
Blind zoneOperating rangeMaximum range
Angle of beam spread
0 to 30 mm 250 mm
0 to 85 mm 350 mm
350 mmPlease see detection zone
600 mmPlease see detection zone
0 to 200 mm 1.300 mm
0 to 350 mm 3.400 mm
2.000 mmPlease see detection zone
5.000 mmPlease see detection zone
0 to 600 mm 6.000 mm8.000 mmPlease see detection zone
Transducer frequencyResolution. sampling rate
ReproducibilityAccuracy
ca. 320 kHz0.025 mm
360 kHz0.025 mm
± 0.15 %± 1 % (Temperature drift internal compensated.
± 0.15 %± 1 % (Temperature drift internal compensated.
Detection zonesfor different objects:
The dark grey areas are determind with a thin round bar (10 or 27 mm dia.) and indicate the typical operating range
of a sensor. In order to obtain the light grey areas. a plate (500 x 500 mm) is introduced
into the beam spread from the side. In doing so, the optimum angle between
plate and sensor is always employed. This therefore indicates the maximum
detection zone of the sensor. It is not possible to evaluate ultrasonic
reflections outside this area.
Opperating voltage UB
Voltage ripple
may be deactivated1). 0.17%/K without compensation) may be deactivated1). 0.17%/K without compensation)
9 V to 30 V DC. reverse polarity protection±10 %
9 V to 30 V DC. reverse polarity protection±10 %
200 kHz0.18 mm
120 kHz0.18 mm
± 0.15 %± 1 % (Temperature drift internal compensated.
± 0.15 %± 1 % (Temperature drift internal compensated.
80 kHz0.18 mm± 0.15 %± 1 % (Temperature drift internal compensated.
may be deactivated1). 0.17%/K without compensation) may be deactivated1). 0.17%/K without compensation)
9 V to 30 V DC. reverse polarity protection±10 %
9 V to 30 V DC. reverse polarity protection±10 %
may be deactivated1). 0.17%/K without compensation)
9 V to 30 V DC. reverse polarity protection±10 %
No-load supply currentHousing
Class of protection to EN 60529
≤ 80 mAStainless steel 1.4571, plastic parts: PBT, TPU;
≤ 80 mAStainless steel 1.4571, plastic parts: PBT, TPU;
Ultrasonic transducer: PEEK film, PTFEIP 67
Ultrasonic transducer: PEEK film, PTFEIP 67
Norm conformityType of connection
ControlsIndicators
EN 60947-5-25-pin initiator plug, PBT
EN 60947-5-25-pin initiator plug, PBT
2 push-buttons (TouchControl)3-digit LED-display, 2 three-colour LEDs
2 push-buttons (TouchControl)3-digit LED-display, 2 three-colour LEDs
≤ 80 mAStainless steel 1.4571, plastic parts: PBT, TPU;
≤ 80 mAStainless steel 1.4571, plastic parts: PBT, TPU;
Ultrasonic transducer: PEEK film, PTFEIP 67
Ultrasonic transducer: PEEK film, PTFEIP 67
≤ 80 mAStainless steel 1.4571, plastic parts: PBT, TPU;Ultrasonic transducer: PEEK film, PTFEIP 67
EN 60947-5-25-pin initiator plug, PBT
EN 60947-5-25-pin initiator plug, PBT
2 push-buttons (TouchControl)3-digit LED-display, 2 three-colour LEDs
2 push-buttons (TouchControl)3-digit LED-display, 2 three-colour LEDs
EN 60947-5-25-pin initiator plug, PBT2 push-buttons (TouchControl)3-digit LED-display, 2 three-colour LEDs
ProgrammableOperating temperature
Storage temperatureWeight
Yes, with TouchControl and LinkControl-25°C to +70°C
Yes, with TouchControl and LinkControl-25°C bis +70°C
-40°C to +85°C150 g
-40°C bis +85°C150 g
Switching hysteresis1)
switching frequency1)
Response time1)
Time delay before availibility
3 mm25 Hz
5 mm12 Hz
32 ms< 300 ms
64 ms< 300 ms
Yes, with TouchControl and LinkControl-25°C bis +70°C
Yes, with TouchControl and LinkControl-25°C bis +70°C
-40°C bis +85°C150 g
-40°C bis +85°C210 g
Yes, with TouchControl and LinkControl-25°C bis +70°C-40°C bis +85°C270 g
20 mm8 Hz
50 mm4 Hz
92 ms< 300 ms
172 ms< 300 ms
100 mm3 Hz240 ms< 300 ms
Order No.Switched output
crm+25/DD/TC crm+35/DD/TC2 x pnp, UB - 2 V, Imax = 2 x 200 mAswitchable NOC/NCC, short-circuit-proof
2 x pnp, UB - 2 V, Imax = 2 x 200 mAswitchable NOC/NCC, short-circuit-proof
1) Can be programmed with TouchControl and LinkControl
crm+130/DD/TC crm+340/DD/TC2 x pnp, UB - 2 V, Imax = 2 x 200 mAswitchable NOC/NCC, short-circuit-proof
2 x pnp, UB - 2 V, Imax = 2 x 200 mAswitchable NOC/NCC, short-circuit-proof
crm+600/DD/TC2 x pnp, UB - 2 V, Imax = 2 x 200 mAswitchable NOC/NCC, short-circuit-proof
+UB
-UB
D1D2Sync/Com
12453
2 pnp switched outputs
U
crm+25… crm+35… crm+130… crm+340… crm+600…
0 cm
5 cm
10 cm
15 cm
20 cm
25 cm
30 cm
35 cm
ausgerichtete Platte
Rohr ø 10 mm
10 c
m
5 cm
0 cm
5 cm
10 c
m
Plate
Round bar
0 cm
10 cm
20 cm
30 cm
40 cm
50 cm
60 cm
ausgerichtete Platte
Rohr ø 27 mm
20 c
m
10 c
m
0 cm
10 c
m
20 c
m
35 cm
Plate
Round bar
0 m
0.4 m
0.8 m
1.2 m
1.6 m
2 m
1.3 m
ausgerichtete Platte
Rohr ø 27 mm
0.8
m
0.4
m
0 m
0.4
m
0.8
m
Plate
Round bar
0 m
0.8 m
1.6 m
2.4 m
3.2 m
4 m
4.8 m
5.6 m
3.4 m
ausgerichtete Platte
Rohr ø 27 mm
1.6
m
0.8
m
0 m
0.8
m
1.6
m
Plate
Round bar
0 m
1.2 m
2.4 m
3.6 m
4.8 m
6 m
7.2 m
8.4 m
ausgerichtete Platte
Rohr ø 27 mm
2.4
m
1.2
m
0 m
1.2
m
2.4
m
Plate
Round bar
microsonic GmbH / Phoenixseestraße 7 / 44263 Dortmund / Germany / T +49 231 975151-0 / F +49 231 975151-51 / E [email protected] / W microsonic.de The content of this document is subject to technical changes. Specifications in this document are presented in a descriptive way only. They do not warrant any product features.