Upload
others
View
3
Download
0
Embed Size (px)
Citation preview
Produktkatalog
Product catalog
Flame monitoring systems for
Single burner
Industrial applications
Flame monitoring systems for
Single burner heating and
Industrial applications
Flame monitoring systems for
2
The company - Who we are BST Solutions GmbH, established 2004 in Ratingen, Germany, offers flame monitoring solutions for residential heating and industrial combustion in different applications. The diversity of applications and functions of these devices are based on the constant exchange of experience and close cooperation with our customers.
We set the trends! BST Solutions has set a number of innovative milestones in flame monitoring technology over the years: • Processor-based Compact Flame Controller with communication ability for heating technology • Universal flame signal output guarantees a wide variety of applications with various burner controls • Over 20 patents covering the entire spectrum of flame monitoring, from basic research and procedures to electronic circuits.
Safety - is our priority Growing demands on safety and increasing significance of environmental protection pose new challenges for industrial plants. The range of BST products offers the right flame monitoring for every combustion process.
Quality - for your satisfaction BST Solutions pays particular attention to the complete testing of its devices before these are delivered to the customer. This guarantees our customers full and long-term operational reliability during use. Quality starts from our Suppliers and components must satisfy our own high standards because a chain always breaks at its weakest link. This is another reason for the reliability of our products.
3
Summary
Device
KLC
10
/11
KLC
20
IFC
/IFR
10
/11
IFC
/IFR
50
KH
M 2
0
ISH
100/
24
Sensor UV-Tube X - X X - X
Sensor Semiconductor
- X - - X -
UV Spectrum 185 to 260nm
X - X X - -
VIS/IR Spectrum 380 to 1150nm
- X - - X -
Viewing direction
radial or
radial and axial
axial axial / radial
axial / radial
axial radial
Mode inter-
mittent inter-
mittent inter-
mittent inter-
mittent inter-
mittent conti-nuous
Self-monitoring - - - - - X
Natural Gas X X* X X X X
Furnace Gas X X* X X X X
Coke Oven Gas X X* X X X X
Light Oil X X X X X X
Heavy Oil X X X X X X
Flame signal FET FET FET Relay Relay Relay
Potential free no no no yes yes yes
Suitable for switching input
X X X X X X
Suitable for ionization input
X X X - X -
Operating temperature -20°C to 60°C
X X X X X X
Fully electronic - X - - X X
Maintenance free - X - - X X
Small size X X - - - -
Robust - - X X X X
Simple installation X X X X X X
Applications
Gas burner,
dual fuel burner
Gas burner,
dual fuel burner
Gas burner,
dual fuel burner
Gas burner,
dual fuel burner
Gas burner,
dual fuel burner
Gas- and oil burner
Industrial Usage - - X X X X
Heating Technology
X X X X X X
4
Flame detector KLC
KLC 10 Is a Compact UV-flame detector for for gas-, oil- and combined fuel burners.developed to meet the requirements of units which make a ‘no-flame’ check after normal burner shut down when the flame amplifier is permanently energizstarted up once in a day.
* Higher sensitivity reduces the lifetime of the UV **On axial orientation, sensitivity is reduced about approx. 40%.
KLC 11
Is a Compact UV flame detector for for gas-, oil- and combined fuel burners. After connecting to the power supplyincrease of the UV tube voltage directly guarantees the safety requirements of 298:2012 by checking a break-through of the UV tube. Therefore an easy change from ionization monitoring to the KUV input.
KLC 20 Wide band KLC 20 is a compact flame detectorfiring systems on residential fan burner applications. flame radiation is used for the patented evaluation.converts the flame signal to a digital signal controls having external wire terminalsunnecessary. For gas applicationsoff is to be used. Take a look to KLC COM software.off should not be used in gas applications.
Description Flame detector KLC 10/230 R, radial Flame detector KLC 10/230 RS , radial & sensitiveFlame detector KLC 10/230 RA, radial & axialFlame detector KLC 10/230 RAS, radial & axialsensitive*
Description Flame detector KLC 11/230 radial Flame detector KLC 11/230 radial & axial
Description Flame detector KLC 20/230 , 25/15 Hz, DFCFlame detector KLC 20/230 , 25/15 HzFlame detector KLC 20/24 DC , 25/15 Hz, DFCFlame detector KLC 20/24 DC, 25/15 HzFlame detector KLC 20/24 AC, 25/15 Hz, DFCFlame detector KLC 20/24 AC, 25/15 Hz
KLC 10/11
*On axial orientation, sensitivity is reduced about approx. 40%.
flame detector for heating and single burner applications, suitable fuel burners. The flame detector KLC 10 has been
developed to meet the requirements of EN 298:2012 for burner management control flame’ check after normal burner shut down when the flame
zed. This Flame detector must be disconnected for
reduces the lifetime of the UV-tube. **On axial orientation, sensitivity is reduced about approx. 40%.
Compact UV flame detector for heating and single burner applications, suitable burners. After connecting to the power supply, internal
increase of the UV tube voltage directly guarantees the safety requirements of through of the UV tube. Therefore an easy change
from ionization monitoring to the KLC 11 is possible also on burner controllers without
KLC 20 compact flame detector*, specially developed for blue burning
fan burner applications. Flicker frequency of the detected flame radiation is used for the patented evaluation. A microprocessor evaluates
ignal to a digital signal that is compatible with most burner controls having external wire terminals. Field setting adjustment or commissioning are
. For gas applications, the implementation with disturbance frequency cut e a look to KLC COM software. Versions without disturbance cut
off should not be used in gas applications.
Order-No. , radial 611041322100
0 RS , radial & sensitive* 611041322160 radial & axial** 611041323100
0 RAS, radial & axial** & 611041323160
Order-No. 611043322100
radial & axial** 611043323100
Order-No. 0 , 25/15 Hz, DFC 611111110105
, 25/15 Hz 611111210105 , 25/15 Hz, DFC 611311110105
DC, 25/15 Hz 611311210105 24 AC, 25/15 Hz, DFC 611611110105
AC, 25/15 Hz 611611210105
reduced about approx.
uitable The flame detector KLC 10 has been
r management control flame’ check after normal burner shut down when the flame
be disconnected for
uitable internal
increase of the UV tube voltage directly guarantees the safety requirements of EN through of the UV tube. Therefore an easy change
without
, specially developed for blue burning licker frequency of the detected
es and that is compatible with most burner
Field setting adjustment or commissioning are the implementation with disturbance frequency cut
Versions without disturbance cut
Accessories for KLC series
Accessories for KLC series
KLC flange
Serves for the admission, connection and adjustment of the flame detectors KLC. Available in 7mm and 13mm
Angle adaptor KLC
With the optionally available corner adaptor the adjustment of the KLC 20 is carried out by means of an optimally formed out reflecting surface to the flame axis. The corner adaptor substitutes at the same time for the connection flange KLC
Adaptor ADP
The adaptor ADP enables to be able to mount the flame guards KLC 20 with additional axial adjustment directly to a fire space opening. A quartz glass serves as a pressure barrier and prevents this resign from heating gases from the combustion chamber.
Connection cable KLC
Consist of angle plug and a cable with stripped and cable ends. The cable length is customized.
Description Order-KLC flange 7mm 665001010000KLC flange 13mm 665002010000
Description Order-Angle adaptor KLC 615001020000
Description Order-Adaptor ADP 11-UV, R ½” Aluminium, quartz glass
575010512
Adaptor ADP 11-UV, R ½”, quartz glass, heat insulator
On request
Description Order-Connection cable KLC , length XX On request
5
for the admission, connection and adjustment of the 13mm.
With the optionally available corner adaptor the radial adjustment of the KLC 20 is carried out by means of an optimally formed out reflecting surface to the flame axis. The corner adaptor substitutes at the same time for the
The adaptor ADP enables to be able to mount the flame guards KLC 20 with additional axial adjustment directly to a fire space opening. A quartz glass serves as a pressure barrier and prevents this resign from heating gases from the
and crimped
-No. 665001010000 665002010000
-No. 615001020000
-No. 575010512210
On request
-No. On request
6
Diagnostic Tool KLC COM
KLC COM is a PC interface with the flame detectorgraphical and numeric display of relevant performance measurements, disturbance frequency cut off and switch status.signal intensity and frequency distribution are the data logging function and be processed with program
RMF
The relay module flame detector the series KLC, IFC 10/11 efficient relay contacts free of potential. With it these flame detectors can be used in PLC or round controls. It indicates his working condition and the status of the flame relay by means of LEDs on the front and seccare of the flame detector electrically. Implementation with special functions can be also provided here.
Description Diagnostic tool KLC COM
Description RMF 230 RMF-R 230 RMF 24 DC RMF-R 24 DC
Diagnostic Tool KLC COM
is a PC interface with the flame detectors KLC 20 and KHM 20 presenting graphical and numeric display of relevant performance measurements, disturbance frequency cut off and switch status. Analysis of the flame signal is possible. Flame
frequency distribution are displayed. This data can be stored with the data logging function and be processed with programs such as MS Excel.
serves for moving of the switching output signal of efficient relay contacts free of potential. With it these flame
or round controls. It indicates his working condition and the status of the flame relay by means of LEDs on the front and secures the tension
electrically. Implementation with special functions can be
Order-No. 731000080980
Order-No. 640480002000 640480002001 640480002200 640480002201
KLC 20 and KHM 20 presenting graphical and numeric display of relevant performance measurements, disturbance
Flame stored with
t signal of efficient relay contacts free of potential. With it these flame
or round controls. It indicates his working condition and ures the tension
electrically. Implementation with special functions can be
7
Compact flame detector IFC/IFR 10/11
IFC/IFR 10/11 is a compact UV flame detector which is specially designed for severe conditions often experienced in industrial application single flame combustion. IFC/IFR 10/11 can be connected directly to the ionisation or LDR input of the control box. The UV sensor ensures that the flame detector does not react to background radiation from hot refractory or from any other infrared light source.
The flame detector IFC/IFR 10 has been developed to meet the requirements of EN 298:2012 for burner management control units which make a ‘no-flame’ check after normal burner shut down when the flame amplifier is permanently energized.
With the diopter holder, which serves also as a mounting of the flame detector to the combustion chamber, the IFC/IFR 10 can be fitted with different glasses and lenses to special requirements. This flame detector is equipped with an optical interface which visibly indicates the flame signal intensity. A simple diagnosis of the flame intensity is directly on the furnace or boiler possible.
Internal increase of the UV tube voltage immediately after applying supply voltage ensures the safety requirement in accordance with the EN 298:2012 for examination of UV tube to through ignition.
* Higher sensitivity reduces the lifetime of the UV-tube.
Description Order-No. IFC 10/230 , axial 611181031000 IFC 10/230 S, axial, sensitive* 611181031160 IFR 10/230 , radial 611191031000 IFR 10/230 S, radial, sensitive* 611191031160 IFC 11/230 , axial 611183031000 IFR 11/230 , radial 611193031000
8
Compact flame detector IFC/IFR 50
IFC/IFR 50 is a compact UV flame detector* who was conceived especially for the application in industrial furnaces. Its internal relay offers one isolated NC contact and an isolated NO contact with high switching performance. Thus, the IFC/IFR 50 is suitable for multi-flame control with ambient light control. The flame detector IFC/IFR 50 is provided according to the EN 298:2012 for firing, which requires a controlled shutdown upon flame signal interruption.
The UV tube ensures that background radiation is ignored, i.e. glowing refractory lining or mixing unit parts. The internal increase of UV tube voltage immediately after supply voltage application complies with EN 298:2012 for examination UV tube on start-up for intermittent type burners.
The diopter serves as mounting interface of the flame detector to the furnace chamber. IFC/IFR 50 can be adapted with various accessories to special applications. A LED indicates flame intensity. Easy diagnosis of the flame intensity is possible with it directly in the combustion apparatus.
Suggested operating temperature range is -20°C to 60°C. Temperatures greater than 50°C reduce the life span of the UV tube. Heat-insulating accessories are available from us.
Description Order-No. IFC 50/230 611185031000 IFR 50/230 611195031000
Compact flame detector K
The wide band flame detector KHM 20 is a compact flame detectorespecially for industrial single burner applicationPLC).The flame signal output is a product of our patented flicker evaluation of any type flame. Field setting adjustment or commissioning are unnecessary. values only the flickering of the flame beconstant frequency, fluorescent lamps or background radiations ignored. The diopter serves as chamber. The KHM 20 can be adapted withcan be adapted to special demands. LED indicates operational parameters (as for example display of the flame modulation, topical switch state in dependence of the flame signal, serial number) are possible. The KLC COM software setemperature range is -20°C and +60°C and greater than 75°C (<1 min) are allowed.
KHM 20 is available in 230 V AC, 24 V AC and 24 V DC with axial viewing. The KHM 20 is equipped with the function of the disturbance frequency cut off. On this occasion, detects the KHM 20 only real flames which mark themselves by an unstabchanging frequency. DC light radiations and any steady frequency, e.g., from fluorescent lamps or other electric lights, are faded out and do not lead to a lasting flame recognition. This function will enable, after the light sensor with a source of light with steady frequency will be impinged, the switching output of the KHM 20 first and after approx. 5-9 seconds it switches off again.
*Compact Flame Detector means it is agencydoes not require a separate amplifier module.
How to order:
Description KHM 20/230 , 25/15 Hz , DFC for ionizationKHM 20/230 , 25/15 Hz , DFC for PLCKHM 20/24 AC, 25/15 Hz, DFC for ionizationKHM 20/24 AC, 25/15 Hz, DFC for PLCKHM 20/24 DC, 25/15 Hz, DFC for ionizationKHM 20/24 DC, 25/15 Hz, DFC for PLC
Compact flame detector KHM 20
The wide band flame detector KHM 20 is a compact flame detector* conceived especially for industrial single burner applications with programmable controls (
The flame signal output is a product of our patented flicker evaluation of any type flame. Field setting adjustment or commissioning are unnecessary. The KHM 20 values only the flickering of the flame being monitored. DC light radiation,
fluorescent lamps or background radiations from refractory are serves as mounting interface of the flame detector to the furnace
can be adapted with glasses, lenses, filters and hole screens special demands. All KHM series accessories are compatible
operational parameters (as for example display of the flame modulation, topical switch state in dependence of the flame signal, serial number) are possible. The KLC COM software serves as an analysis tool. Suggested operating
20°C and +60°C and short duration temperature excursions (<1 min) are allowed.
0 V AC, 24 V AC and 24 V DC with axial viewing. The KHM equipped with the function of the disturbance frequency cut off. On this
occasion, detects the KHM 20 only real flames which mark themselves by an unstabchanging frequency. DC light radiations and any steady frequency, e.g., from
her electric lights, are faded out and do not lead to a lasting flame recognition. This function will enable, after the light sensor with a source of light with steady frequency will be impinged, the switching output of the KHM 20 first and
9 seconds it switches off again.
*Compact Flame Detector means it is agency-certified as a stand-alone device that does not require a separate amplifier module.
Order-No. for ionization 611131130105
for PLC 611131130205 for ionization 611631130105 for PLC 611631130205 for ionization 611331130105 for PLC 611331130205
9
conceived programmable controls (i.e.
The flame signal output is a product of our patented flicker evaluation of any The KHM 20
monitored. DC light radiation, any from refractory are
o the furnace glasses, lenses, filters and hole screens
compatible. A operational parameters (as for example display of the flame
modulation, topical switch state in dependence of the flame signal, serial number) are operating
excursions
0 V AC, 24 V AC and 24 V DC with axial viewing. The KHM
occasion, detects the KHM 20 only real flames which mark themselves by an unstable
her electric lights, are faded out and do not lead to a lasting flame recognition. This function will enable, after the light sensor with a source of light with steady frequency will be impinged, the switching output of the KHM 20 first and
alone device that
10
Compact Flame Controller
The ISH 100/24 is a compact UV flame detector, which especially for combustion systems of gas-shaped and oil-shaped fuels in single burner applications which generate nearly no radiation in the visible light spectrum or work with very low developed. The robust case of the flame detector ISH 100/24 also allows the application in particular for industrial applications. His operational area encloses gas fan burner and combination burner in the continuous operation for frcontrols with external flame detector or ionization input.
The used UV tube guarantees that background radiations, are not recogniglowing brick linings or mixing unit parts. About the flashing frequency aannouncement the pulse frequency of the UV tube is easy in dependence of the flame intensity to recognize. An easy diagnosis of the flame intensity is possible with it directly in the combustion apparatus. This makes easier the The second LED signals the status of the switching output of the flame detector.
The plug connection of the connecting cable and the push flange offer an easy assembly and adjustment of the ISH 100/24. The UV tubewithout considerable expenditure
Standardized Product
Flame detector ISH 100/24
Flame detector ISH 100s/24
Accessories
Connecting cable with angle plug
Connecting cable with angle plug
Clamp flange
Compact Flame Controller ISH 100
he ISH 100/24 is a compact UV flame detector, which especially for combustion systems of shaped fuels in single burner applications which generate nearly no
radiation in the visible light spectrum or work with very low flame modulation, been developed. The robust case of the flame detector ISH 100/24 also allows the application in particular for industrial applications. His operational area encloses gas fan burner and combination burner in the continuous operation for freely programmable controls and burner controls with external flame detector or ionization input.
The used UV tube guarantees that background radiations, are not recognized, e.g., by glowing brick linings or mixing unit parts. About the flashing frequency a LED as an optical announcement the pulse frequency of the UV tube is easy in dependence of the flame
e. An easy diagnosis of the flame intensity is possible with it directly in the combustion apparatus. This makes easier the adjustment of the ISH 100/24 to the flame. The second LED signals the status of the switching output of the flame detector.
The plug connection of the connecting cable and the push flange offer an easy assembly ISH 100/24. The UV tube is easily serviced and can be exchanged
without considerable expenditure.
Version Article number
radial, left, 24V DC 611352323210
radial, left, changeover contact instead of current output
611352323220
version Article number
length 1,80 m 561313041500
length 3,00 m 561313043000
aluminium 365052300000
he ISH 100/24 is a compact UV flame detector, which especially for combustion systems of shaped fuels in single burner applications which generate nearly no
flame modulation, been developed. The robust case of the flame detector ISH 100/24 also allows the application in particular for industrial applications. His operational area encloses gas fan burner and
eely programmable controls and burner
ed, e.g., by LED as an optical
announcement the pulse frequency of the UV tube is easy in dependence of the flame e. An easy diagnosis of the flame intensity is possible with it directly in
adjustment of the ISH 100/24 to the flame.
The plug connection of the connecting cable and the push flange offer an easy assembly and can be exchanged
Article number
611352323210
611352323220
Article number
561313041500
561313043000
365052300000
11
12
© BST Solutions 2016
BST Solutions GmbH
Eggerscheidter Str. 57 D-40883 Ratingen
Tel.: +49 2102 100 59 59 Fax.: +49 2102 100 59 79
E-Mail: [email protected] Web: www.bst-solutions.de
Your sales partner: