Upload
others
View
3
Download
0
Embed Size (px)
Citation preview
PROCOS RELEASE
SPECIFICATION CUSTOMER BASELINE Department: Industrial Document ID: CBAS001 Date: 2013-10-24 Version: 04.03
Page 2 of 36 PROCOS Release Specification
Date: 2013-10-24 Document ID: CBAS001 Version: 04.03
File: CBAS001_v04-03 ReleaseSpec
COPYRIGHT NOTICE © Copyright CGI Danmark A/S This document and its contents are the confidential property of CGI Danmark A/S. It should not be copied, reproduced, modified, altered, or circulated to any third party, in any form or media, without the prior written consent of CGI Danmark A/S.
APPROVALS
Version Initials Signature Date
04.03
Prepared by / CGI
Approved by / CGI QA
Approved by / CGI
DOCUMENT CHANGE LOG
Version Date Initials Pages Affected Short Description of Change
01.00-03.05
2003-11-24 2008-11-27
HAJEO / ANWOL /
KILRA All
For details about changes in version numbers lower than 3.00: See this document v. 03.05 or earlier.
03.06 2009-12-08 KILRA All New Baseline. USM updates. Design Specifications and Test Documents added.
04.00 2010-09-29 KILRA All New Baseline. USM updates.
04.01 2011-10-12 ANWOL/
KILRA All
New logo.
New Baseline
04.02 2012-12-14 ANWOL All New Baseline
04.03 2013-10-24 VAHAN All New logo.
New Baseline
PROCOS Release Specification Page 3 of 36
Document ID: CBAS001 Version: 04.03 Date: 2013-10-24
File: CBAS001_v04-03 ReleaseSpec
CONTENTS
1. INTRODUCTION ............................................................................................................................ 5 1.1. PURPOSE ................................................................................................................................. 5 1.2. SCOPE ...................................................................................................................................... 5 1.3. APPLIES TO ............................................................................................................................. 5 1.4. ABBREVIATIONS AND DEFINITIONS .................................................................................... 6 1.5. REFERENCE DOCUMENTS .................................................................................................... 6
2. MAJOR ENHANCEMENTS ........................................................................................................... 7 2.1. CASE SENSITIVE LOGIN – ILS 3230 ...................................................................................... 7 2.2. INSTRUCTIONS WITH TEXT PARAMETERS – ILS 3233 ...................................................... 7 2.3. EXTENDED SEND CONTROLLER (SNX) – ILS 3506 ............................................................ 7 2.4. CUSTOM SCAN ON CONTROLLER EXECUTOR – ILS 3511 ................................................ 7 2.5. RELATIONAL OPERATORS <=, >=, AND <> ADDED TO SEQ FOR IPC AND
CONTROLLER EXECUTOR – ILS 3520 .................................................................................. 7 2.6. IPC STANDARD PICTURES IMPROVEMENTS ...................................................................... 8
2.6.1. PID User Interface – ILS 2010 ..................................................................................... 8 2.6.2. Information about filtering and Inverted/Normal conversion – ILS 3371 ..................... 8
2.7. CHANGE PRIORITY OF PIU-TASKS IN IPC – ILS 3538 ........................................................ 8 2.8. ADD MISSING BATCH IDS IN BATCH EXECUTOR – ILS 3543 ............................................ 8 2.9. LIMITATION OF NET MIMIC LIST – ILS 3473 ......................................................................... 8 2.10. EXTRACT FOR CBAS V. 04.00 FROM NEW ENGINEERING DATABASE – ILS
3516 .......................................................................................................................................... 8 2.11. PRINTERS ADDED TO SETUP REPORT – ILS 3532 ............................................................. 8
3. SUPPORT REMOVED ................................................................................................................... 9
4. BASELINE CHANGES FROM PREVIOUS BASELINE ............................................................. 11
5. TEST OUTLINES ......................................................................................................................... 13 5.1. TEST SHORTAGES ............................................................................................................... 13 5.2. TEST REPORT CONCLUSIONS ........................................................................................... 13
5.2.1. Conclusions from TREP072 – Component Integration Test ..................................... 13 5.2.2. Conclusions from TREP073 - System Test Report CBAS001 v. 04.03 .................... 14
6. PROCOS BASELINE .................................................................................................................. 15 6.1. PROCOS VERSION 6.05 ....................................................................................................... 15 6.2. INDUSTRIAL PROCESS CONTROLLER .............................................................................. 15 6.3. USER MANUALS .................................................................................................................... 16 6.4. FUNCTIONAL SPECIFICATIONS .......................................................................................... 17 6.5. DESIGN SPECIFICATIONS ................................................................................................... 17 6.6. DETAILED DESIGN SPECIFICATIONS................................................................................. 17 6.7. AUTOMATIC TEST SPECIFICATIONS.................................................................................. 18 6.8. MANUAL TEST SPECIFICATIONS ........................................................................................ 18 6.9. TEST DATA DOCUMENTS .................................................................................................... 19 6.10. TEST SCRIPT DOCUMENTS ................................................................................................ 20 6.11. TEST PLANS .......................................................................................................................... 20 6.12. TEST REPORTS..................................................................................................................... 20 6.13. TRACEABILITY MATRIX ........................................................................................................ 21
7. PROCOS BASIS .......................................................................................................................... 23 7.1. DEVELOPER TOOLS ............................................................................................................. 23 7.2. OPERATING SYSTEM REQUIREMENTS ............................................................................. 23 7.3. DATABASE SYSTEM REQUIREMENTS ............................................................................... 23 7.4. SENTINEL DRIVER FOR DONGLES .................................................................................... 23 7.5. ESW PACKAGES AND IPC REQUIREMENTS ..................................................................... 23 Appendix A Corrections since last Customer Baseline ............................................................ 25 Appendix B Known Errors and Workarounds ............................................................................ 33 Appendix C PIU EPROM for Process InterfaceModules ........................................................... 35
Page 4 of 36 PROCOS Release Specification
Date: 2013-10-24 Document ID: CBAS001 Version: 04.03
File: CBAS001_v04-03 ReleaseSpec
(Blank page)
PROCOS Release Specification Page 5 of 36
Document ID: CBAS001 Version: 04.03 Date: 2013-10-24
File: CBAS001_v04-03 ReleaseSpec
1. INTRODUCTION
1.1. PURPOSE
The objective of this document is to describe the PROCOS Customer Baseline and thereby supply the PROCOS customers with the necessary knowledge to decide upon an update of an existing PROCOS system. PROCOS is the name of the Windows version of CGI's process control system suite.
The Customer Baseline basis in this document describes which versions of the ESW Packages are qualified to be delivered to customers along with valid User Manuals. Additional internal PROCOS documentation is also baselined.
1.2. SCOPE
This document describes the changes made from the previous baseline to this including references to any Test Reports issued during this period.
The document includes the following important issues:
Major Enhancements, chapter 2.
Support removed, chapter 3.
Changes from previous baseline, chapter 4.
Test shortages, section 5.1.
Conclusions from Test Reports, section 5.2.
PROCOS Mapplications version list, section 6.1.
IPC version list, section 6.2.
USM version list, sections 6.3.
Corrected ILS since the last Customer Baseline, including error corrections as well as improvements, Appendix A .
Known Errors and Workarounds, Appendix B .
Installation notes describing important matters concerning the installation of the present baseline are included on the baseline CD (Install.txt).
Chapter 2 Major Enhancements describes changes in PROCOS Customer Baseline version 04.03 versus version 04.02.
1.3. APPLIES TO
This document applies to Configuration Management to secure that the correct versions are used in delivery to customers and to create trace ability between related elements. Related configuration elements are an ESW Package, IPC5xx, IPC91x, User Manuals (USM) and additional documentation – see chapter 6.
The document may also be used by customers to decide whether to update their system.
Page 6 of 36 PROCOS Release Specification
Date: 2013-10-24 Document ID: CBAS001 Version: 04.03
File: CBAS001_v04-03 ReleaseSpec
1.4. ABBREVIATIONS AND DEFINITIONS
ESW: Software Module. A name and a four-digit number identify each ESW.
USM: User Manual
IPC: Industrial Process Controller
1.5. REFERENCE DOCUMENTS
[1] USM_103 “Installation” User Manual for Windows
[2] USM_125 “PROCOS Reporting” User Manual
[3] TREP072 “Component Integration Test Report - ILS Test before CBAS001 v 04.03”
[4] TREP073 “System Test CBAS 04.03 – System Test Report”
[5] TBAS001 “PROCOS Base Line Functional Test, v. 04.65”
PROCOS Release Specification Page 7 of 36
Document ID: CBAS001 Version: 04.03 Date: 2013-10-24
File: CBAS001_v04-03 ReleaseSpec
2. MAJOR ENHANCEMENTS
This chapter includes a brief description of the major enhancements available with this release.
Please refer to Appendix A for a complete list of error corrections and improvements to PROCOS in this release.
2.1. CASE SENSITIVE LOGIN – ILS 3230
It is now possible to use case sensitive passwords on PROCOS systems with advanced user access control.
In the User Administration Tool the field “Use case sensitive passwords” indicates whether passwords are case sensitive or not. Changing this setting takes effect immediately (also for existing passwords).
The field “Require both upper- and lowercase” indicates whether passwords should have both upper- and lowercase letters.
This feature is only available on Oracle 11g or later.
2.2. INSTRUCTIONS WITH TEXT PARAMETERS – ILS 3233
The following instructions are now available with a MSG_ID or a text parameter in IPC and Controller Executor:
AONL
AONM
AONH
MSG
OPR
PUT
GET (IPC only).
The current alarm text has been added to the SEQ and CTL standard pictures as well.
2.3. EXTENDED SEND CONTROLLER (SNX) – ILS 3506
The Send eXtended Controller (SNX) is used for transmission of all types of point values from one IPC to another.
SNX sends up to 31 point values to destination points in another IPC. It is not recommended to send string points with long values due to the package overhead associated with long string point values.
A point is sent
when the point value has changed more than hysteresis since it was sent last time
at predetermined intervals (Hysteresis Max. Seconds)
first time an error is detected on a point sent
first time it takes more than 5 seconds to get a response from the last sent package
points failed is sent again every Retransmit Delay seconds
2.4. CUSTOM SCAN ON CONTROLLER EXECUTOR – ILS 3511
The Custom scan is intended to make special scan intervals available for each Controller Executor. An example could be to make a scan that is faster than the standard Very Fast scan, however care shall be taken not to put too many controllers in such an extra fast scan class. The value of Custom scan is specified as an environment parameter for each Controller Executor.
2.5. RELATIONAL OPERATORS <=, >=, AND <> ADDED TO SEQ FOR IPC AND CONTROLLER EXECUTOR – ILS 3520
These are operators for comparison of two analog, counter or string expressions.
Page 8 of 36 PROCOS Release Specification
Date: 2013-10-24 Document ID: CBAS001 Version: 04.03
File: CBAS001_v04-03 ReleaseSpec
2.6. IPC STANDARD PICTURES IMPROVEMENTS
2.6.1. PID User Interface – ILS 2010
In order to improve readability the D and I terms have been removed from the standard picture when they are not defined in Engineering Tool..
2.6.2. Information about filtering and Inverted/Normal conversion – ILS 3371
The standard picture for AI points now includes information about filtering.
The standard pictures for DI, DO, Dom, Dof now includes information about Inverted/normal conversion.
2.7. CHANGE PRIORITY OF PIU-TASKS IN IPC – ILS 3538
Tests have shown that the PIU-tasks in the IPC might run at a lower priority than expected due to the prioritizing algorithm used by QNX. This might result in scan overflow in heavy load situations. Consequently a solution has been implemented to ensure that the PIU-tasks handling the serial input/output run at a higher priority.
2.8. ADD MISSING BATCH IDS IN BATCH EXECUTOR – ILS 3543
The Batch Executor now has an additional utility: EmBatUtil.exe
This utility can be used to add missing Batch IDs to the BAT-EXEC Mapplication. This may be relevant in cases, where the Batch IDs known by BAT-EXEC are lost.
2.9. LIMITATION OF NET MIMIC LIST – ILS 3473
Only MIMICs on stations that are loadable now appear in the downloading list in PIC-TOOL.
2.10. EXTRACT FOR CBAS V. 04.00 FROM NEW ENGINEERING DATABASE – ILS 3516
This feature makes it easier to extract from a new Engineering database on a test system (CBAS v. 04.02) and merge this file into an older factory system (e.g. CBAS v. 04.00 or CBAS v. 04.01).
2.11. PRINTERS ADDED TO SETUP REPORT – ILS 3532
Printers are now included in the Setup Report ([Tools] [Report]).
PROCOS Release Specification Page 9 of 36
Document ID: CBAS001 Version: 04.03 Date: 2013-10-24
File: CBAS001_v04-03 ReleaseSpec
3. SUPPORT REMOVED
The following Mapplications are no longer supported:
N/A
The following User Manuals are no longer valid:
N/A
The following Operation Systems are no longer supported:
N/A
Page 10 of 36 PROCOS Release Specification
Date: 2013-10-24 Document ID: CBAS001 Version: 04.03
File: CBAS001_v04-03 ReleaseSpec
(Blank page)
PROCOS Release Specification Page 11 of 36
Document ID: CBAS001 Version: 04.03 Date: 2013-10-24
File: CBAS001_v04-03 ReleaseSpec
4. BASELINE CHANGES FROM PREVIOUS BASELINE
This software included in this baseline corresponds with internal baseline 04.65 – also covering internal baselines
04.53
04.54
04.56
04.58
04.61 - 04.64.
See Ref. [5] TBAS001 “PROCOS Base Line Functional Test, v. 04.65”.
Updated Mapplications
ESW2500 Basic Software
ESW2501 Bar Code Access Control
ESW2504 DB-IF Data Archiving
ESW2506 Token Access Control
ESW2507 Utilities
ESW2508 Data Set Executor
ESW2509 User Access Control
ESW2510 User Administration Tool
ESW2511 PicTool
ESW2512 Controller Tool
ESW2520 LogBook
ESW2521 Mimic
ESW2523 Trend
ESW2524 Alarm Display
ESW2526 Log Display
ESW2527 SPR-IF
ESW2531 Log
ESW2532 Collect
ESW2533 DB-IF
ESW2534 Controller Executor
ESW2535 SQL Gateway
ESW2538 OPC Server
ESW2539 OPC Client Gateway
ESW2542 TwinCAT ADS Gateway
ESW2543 IPC Gateway Lan
ESW2546 SINEC-H1 Gateway
ESW2550 AB KF2 GWY
ESW2559 ASCII I/O
ESW2562 Modbus Gateway
ESW2580 EngTool
ESW2581 ESign Tool
Page 12 of 36 PROCOS Release Specification
Date: 2013-10-24 Document ID: CBAS001 Version: 04.03
File: CBAS001_v04-03 ReleaseSpec
ESW2582 IPC Tool
ESW2585 Gateway Tool
ESW2591 SMS Tool
ESW2595 IPC Standard Pictures
ESW2599 Demo Data
ESW2600 Oracle Supplement
ESW2601 Engineering DB-IF
ESW2700 Report Web Server
ESW2911 Batch Tool
ESW2912 Batch Executor
ESW2913 Batch Std. Pictures
ESW9911 IPC Executor
New Mapplications
none
Renamed Mapplications
none
Updated Industrial Process Controllers
IPC91x
IPC5xx
PROCOS Release Specification Page 13 of 36
Document ID: CBAS001 Version: 04.03 Date: 2013-10-24
File: CBAS001_v04-03 ReleaseSpec
5. TEST OUTLINES
The conclusions upon the test of the internal baselines mentioned in chapter 5.2 are described in:
Ref. [3] TREP072 “Component Integration Test Report - ILS Test before CBAS001 v 04.03”.
Ref. [4] TREP073 “System Test CBAS 04.03 – System Test Report”.
5.1. TEST SHORTAGES
Mapplications not in use in System Test:
• ESW2506 Token Access Control
• ESW2509 User Access Control
• ESW2510 User Administration Tool
• ESW2520 LogBook
• ESW2527 SPR-IF
• ESW2538 OPC Server
• ESW2542 TwinCAT ADS Gateway
• ESW2546 SINEC_H1 Gateway
• ESW2559 ASCII I/O
• ESW2562 Modbus Gateway
• ESW2581 ESign Tool
• ESW2700 Report Web Server
• ESW2701 Report Web Client
• ESW9700 Custom Reports for Kemwell C3B
• ESW9701 Custom Reports for Novozymes EC
• ESW9911 IPC Executor
Only an IPC of type IPC531 with Beckhoff I/O modules was used for the system test, which means that cassette IPC911 with PIU modules and PLC drivers was not used.
5.2. TEST REPORT CONCLUSIONS
In the sections below the main conclusions from the Test Reports issued in connection with the release of this Customer Baseline are listed.
5.2.1. Conclusions from TREP072 – Component Integration Test
During the test period 52 ILS with software errors/change request were corrected and tested ok in relation to this test report.
1 ILS has not been possible to test functionally, but will be tested in system test.
In the test period 10 new software errors were raised, which means that net 42 ILS related to software were corrected in the period.
Page 14 of 36 PROCOS Release Specification
Date: 2013-10-24 Document ID: CBAS001 Version: 04.03
File: CBAS001_v04-03 ReleaseSpec
5.2.2. Conclusions from TREP073 - System Test Report CBAS001 v. 04.03
The test period went well on the Novo Nordisk GePP test plant. The test was conducted as planned. No problems were experienced in connection with the error corrections and new functionality made in the PROCOS Mapplications and the IPC. No other unintentional side-effects of the corrections were experienced. So bearing in mind the test shortages listed in section 5.1 there does not appear to be anything that should prevent that this software should be part of a Customer Baseline on the basis of Ref. [5] TBAS001 “PROCOS Base Line Functional Test, v. 04.65”.
PROCOS Release Specification Page 15 of 36
Document ID: CBAS001 Version: 04.03 Date: 2013-10-24
File: CBAS001_v04-03 ReleaseSpec
6. PROCOS BASELINE
6.1. PROCOS VERSION 6.05
ESW2500 - Basic Software v. 6.05.0400 ESW2501 - Bar Code Access Control v. 6.05.0000 ESW2504 - DB-IF Data Archiving v. 6.05.0000 ESW2506 - Token Access Control v. 6.05.0000 ESW2507 - Utilities - Test (Client/Server) v. 6.05.0100 ESW2508 - Data Set Executor v. 6.05.0100 ESW2509 - User Access Control v. 6.05.0100 ESW2510 - User Administration Tool v. 6.05.0000 ESW2511 - PicTool v. 6.05.0300 ESW2512 - Controller Tool v. 6.05.0300 ESW2520 - LogBook v. 6.05.0000 ESW2521 - Mimic v. 6.05.0400 ESW2523 - Trend v. 6.05.0000 ESW2524 - Alarm Display v. 6.05.0000 ESW2526 - Log Display v. 6.05.0000 ESW2527 - SPR-IF v. 6.05.0000 ESW2531 - Log v. 6.05.0200 ESW2532 - Collect v. 6.05.0200 ESW2533 - DB-IF v. 6.05.0100 ESW2534 - Controller Executor v. 6.05.0200 ESW2535 - SQL Gateway v. 6.05.0100 ESW2538 - OPC Server v. 6.05.0000 ESW2539 - OPC Client Gateway v. 6.05.0000 ESW2542 - TwinCAT ADS Gateway v. 6.05.0000 ESW2543 - IPC Gateway Lan v. 6.05.0400 ESW2546 - SINEC H1 Gateway v. 6.05.0000 ESW2559 - ASCII I/O v. 6.05.0000 ESW2562 - Modbus Gateway v. 6.05.0000 ESW2580 - EngTool v. 6.05.0300 ESW2581 - ESign Tool v. 6.05.0000 ESW2582 - IPC Tool v. 6.05.0100 ESW2585 - Gateway Tool v. 6.05.0100 ESW2591 - SMS Tool v. 6.05.0000 ESW2595 - IPC Standard Pictures v. 6.05.0200 ESW2599 - Demo Data v. 6.05.0000 ESW2600 - Oracle Supplement v. 6.05.0000 ESW2601 - Engineering DB-IF v. 6.05.0100 ESW2700 - Report Web Server v. 6.05.0000 ESW2701 - Report Web Client v. 6.05.0000 ESW2911 - Batch Tool v. 6.05.0000 ESW2912 - Batch Executor v. 6.05.0200 ESW2913 - Batch Std. Pictures v. 6.05.0000 ESW9700 - Custom Reports for Kemwell C3B v. 6.00.0600 ESW9701 - Custom Reports for NZ-EC v. 6.02.0300 ESW9911 - IPC Executor v. 6.05.0400 EM1624 - Disable Audit Triggers v. 6.05.0000
6.2. INDUSTRIAL PROCESS CONTROLLER
Baseline Industrial Process Controller
IPC5xx v. 6.05.0400 IPC9xx v. 6.05.0400
Page 16 of 36 PROCOS Release Specification
Date: 2013-10-24 Document ID: CBAS001 Version: 04.03
File: CBAS001_v04-03 ReleaseSpec
6.3. USER MANUALS
USM_005 - Introduction v. 06.01
USM_007 – PicTool v. 06.07
USM_008 - Mimic v. 06.05
USM_010 – Trend v. 06.08
USM_015 - Alarm Display v. 06.06
USM_018 – Log v. 06.06
USM_019 - Gateway to PROCOS IPC v. 06.08
USM_024 - Collect v. 06.04
USM_025 - DB-IF v. 06.11
USM_026 - Gateway to Siemens SINEC® H1 incl. 3964R v. 06.05
USM_027 – SPRIF v. 06.03
USM_028 - Controller Executor v. 06.06
USM_029 - Controller Tool v. 06.06
USM_041 - SQL Gateway v. 06.03
USM_061 - Gateway to Modbus PLCs v. 06.03
USM_068 - ASCII I/O Mapplication v. 06.06
USM_074 - IPC Tool v. 06.13
USM_077 - Engineering Tool v. 06.10
USM_078 - Gateway Tool v. 06.04
USM_080 – PicTool - The MMS Specific Dialogs v. 06.04
USM_085 - Batch Tool v. 06.06
USM_086 - Batch Executor v. 06.04
USM_096 – OPC Server v. 06.01
USM_100 - Data Set Executor v. 06.03
USM_101 - User Administration v. 06.04
USM_103 - Installation - Windows v. 06.06
USM_104 - Workbench – Windows v. 06.08
USM_105 - Setup - Windows v. 06.05
USM_107 - DB-IF Data Archiving v. 06.05
USM_109 - Oracle 9i Installation v. 06.06
USM_113 - Disable Audit Triggers v. 06.04
USM_114 - Log Display v. 06.07
USM_115 - EngDB-IF v. 06.03
USM_117 - Electronic Signature v. 06.05
USM_118 - OPC Client Gateway v. 06.05
USM_119 - Token Access Control v. 06.03
USM_121 - Installation of Win XP v. 06.05
USM_122 - Installation of Win Server 2003 v. 06.05
USM_124 - IPC Executor v. 06.03
USM_125 - PROCOS Reporting v. 06.12
USM_126 - Oracle 10g Installation v. 06.06
PROCOS Release Specification Page 17 of 36
Document ID: CBAS001 Version: 04.03 Date: 2013-10-24
File: CBAS001_v04-03 ReleaseSpec
USM_127 - Configuration of IPC and PIU with Beckhoff IO v. 06.04
USM_128 - Bar Code Access Control v. 06.03
USM_129 - SMS Tool v. 06.06
USM_131 - PROCOS Technical System Description v. 06.02
USM_132 - TwinCAT ADS Gateway v. 06.02
USM_135 – Installation of Windows Server 2008 v. 06.04
USM_136 – Installation of Windows 7 v. 06.04
USM_137 – Oracle11g Installation on Windows v. 06.05
USM_138 – LogBook v. 06.02
6.4. FUNCTIONAL SPECIFICATIONS
FSP_001 - PROCOS 21 CFR Part 11 v. 01.04
6.5. DESIGN SPECIFICATIONS
DSP_002 - PROCOS Module/Document list v. 01.10
6.6. DETAILED DESIGN SPECIFICATIONS
DDSP001 – P-Environment v. 06.01
DDSP003 – Scan Module v. 06.01
DDSP004 – Operator Capabilities v. 06.01
DDSP005 – Cryptographic Library v. 06.01
DDSP006 – TRACEDISP Mapplication v. 06.01
DDSP007 – Windows Workbench v. 06.01
DDSP008 – Windows Installation v. 06.01
DDSP009 – Windows Setup v. 06.01
DDSP010 – Tag Server v. 06.01
DDSP011 – P-Environment, LAN Manager Option v. 06.01
DDSP012 – Mimic v. 06.01
DDSP013 – Trend v. 06.01
DDSP014 – AlarmDisp v. 06.01
DDSP015 – LogDisp v. 06.01
DDSP016 – User Access Validation v. 06.01
DDSP017 – Download v. 06.01
DDSP019 – Session v. 06.01
DDSP022 – LOG v. 06.02
DDSP029 – Merge/Extract v. 06.01
DDSP030 – SeqTool v. 06.01
DDSP032 – Batch Executor v. 06.01
DDSP034 – DB-IF v. 06.01
DDSP035 – SQL Gateway v. 06.01
DDSP038 – CtlExec v. 06.01
DDSP046 – IPC Gateway v. 06.01
Page 18 of 36 PROCOS Release Specification
Date: 2013-10-24 Document ID: CBAS001 Version: 04.03
File: CBAS001_v04-03 ReleaseSpec
DDSP048 – Enhanced Gwy v. 06.01
DDSP052 – Data Set Executor v. 06.01
DDSP053 – ENG-DBIF v. 06.01
DDSP054 – Disable Audit Triggers v. 06.01
DDSP056 – SQLOCI v. 06.01
DDSP057 – TagLib v. 06.01
DDSP058 – Collect v. 06.01
DDSP059 – Token Access Control v. 06.01
DDSP060 – Report Web Server v. 06.02
DDSP061 – Report Standard CR v. 06.05
DDSP066 – IPC_GWY Protocol v. 06.02
DDSP067 – Socket Library v. 06.01
DDSP068 – TwinCAT ADS Gateway v. 06.01
DDSP070 – IPC v. 06.01
DDSP071 – LogBook Mapplication v. 06.02
DDSP072 – OPC Server v. 06.01
6.7. AUTOMATIC TEST SPECIFICATIONS
ASPE028 – CtlExec Mapplication v. 01.00
ASPE100 – DatExec Mapplication v. 01.00
ASPE104 – Workbench Mapplication v. 01.01
ASPE300 – Test of IPC9XX v. 01.03
ASPE301 – IPC and Beckhoff I/O v. 01.02
6.8. MANUAL TEST SPECIFICATIONS
MSPE007 – PicTool Mapplication v. 02.11
MSPE008 – Mimic Mapplication v. 01.07
MSPE010 – Trend Mapplication v. 01.09
MSPE015 – AlarmDisp Mapplication v. 01.07
MSPE017 – Oracle Run Time Option v. 01.00
MSPE018 – Log Mapplication v. 02.04
MSPE019 – Gateway to PROCOS IPC v. 02.04
MSPE024 – Collect Mapplication v. 01.07
MSPE025 – DB-IF Mapplication v. 02.03
MSPE026 – Gateway to SINEC H1 (Simulator) v. 01.01
MSPE027 – SPR-IF Mapplication v. 01.01
MSPE028 – CtlExec Mapplication v. 01.05
MSPE029 – CtlTool Mapplication v. 01.05
MSPE041 – SQL Gateway Mapplication v. 01.03
MSPE061 – Gateway to Modbus PLCs v. 01.02
MSPE068 – ASCII-I/O Mapplication v. 01.02
MSPE074 – IPC Tool – IPC Engineering Mapplication v. 01.04
PROCOS Release Specification Page 19 of 36
Document ID: CBAS001 Version: 04.03 Date: 2013-10-24
File: CBAS001_v04-03 ReleaseSpec
MSPE077 – EngTool Mapplication, Basic Engineering v. 01.10
MSPE078 – GwyTool Mapplication v. 01.04
MSPE085 – BatTool Mapplication v. 01.05
MSPE086 – BatExec Mapplication v. 01.09
MSPE096 – OPC Server v. 01.00
MSPE100 – DatExec Mapplication v. 01.02
MSPE101 – User Administration Tool v. 01.08
MSPE107 – DB-IF Data Archiving v. 01.07
MSPE109 – Oracle Installation on Windows v. 01.03
MSPE113 – Disable Audit Triggers v. 02.01
MSPE114 – LogDisp Mapplication v. 01.02
MSPE115 – Engineering DB-IF Mapplication v. 01.01
MSPE117 – Electronic Signature v. 01.03
MSPE118 – OPC Client Gateway v. 01.04
MSPE119 – Token v. 01.01
MSPE124 – IPC Executor v. 01.01
MSPE125 – PROCOS Standard Reports v. 01.05
MSPE126 – Oracle10 Installation v. 01.01
MSPE128 – Bar Code Access Control v. 01.01
MSPE129 – SMS Tool Mapplication v. 01.02
MSPE132 – TwinCAT ADS Gateway Mapplication v. 01.01
MSPE134 – LAN Environment, TCP/IP v. 01.01
MSPE137 – Oracle 11g Installation v. 01.03
MSPE138 – LogBook v. 01.01
MSPE302 – IPC Test PIU v. 01.01
6.9. TEST DATA DOCUMENTS
TDAT007 – PicTool Mapplication v. 02.03
TDAT008 – Mimic Mapplication v. 01.02
TDAT010 – Trend Mapplication v. 01.03
TDAT015 – AlarmDisp Mapplication v. 01.01
TDAT018 – Log Mapplication v. 01.04
TDAT019 – Gateway to PROCOS IPC v. 01.02
TDAT024 – Collect Mapplication v. 01.03
TDAT025 – DB-IF Mapplication v. 03.03
TDAT026 – Gateway to SINEC H1 (Simulator) v. 01.00
TDAT027 – SPR-IF Mapplication v. 01.00
TDAT028 – CtlExec Mapplication v. 01.04
TDAT029 – CtlTool Mapplication v. 01.02
TDAT041 – SQL Gateway Mapplication v. 01.02
TDAT061 – Gateway to Modbus PLCs v. 01.00
TDAT068 – ASCII-I/O Mapplication v. 01.02
Page 20 of 36 PROCOS Release Specification
Date: 2013-10-24 Document ID: CBAS001 Version: 04.03
File: CBAS001_v04-03 ReleaseSpec
TDAT074 – IPC Tool – IPC Engineering Mapplication v. 01.03
TDAT077 – EngTool Mapplication, Basic Engineering v. 01.06
TDAT078 – GwyTool Mapplication v. 01.01
TDAT085 – BatTool Mapplication v. 01.02
TDAT086 – BatExec Mapplication v. 01.06
TDAT096 – OPC Server v. 01.00
TDAT100 – DatExec Mapplication v. 01.01
TDAT101 – User Administration Tool v. 02.01
TDAT104 – Workbench Mapplication WIN v. 02.02
TDAT107 – DB-IF Data Archiving v. 01.07
TDAT114 – LogDisp Mapplication v. 01.01
TDAT115 – Engineering DB-IF Mapplication v. 01.02
TDAT117 – Electronic Signature v. 01.02
TDAT118 – OPC Client Gateway v. 01.02
TDAT119 – Token v. 01.00
TDAT124 – IPC Executor v. 01.01
TDAT125 – PROCOS Standard Reports v. 01.04
TDAT128 – Bar Code Access Control v. 01.00
TDAT129 – SMS Tool Mapplication v. 01.01
TDAT132 – TwinCAT ADS Gateway Mapplication v. 01.01
TDAT134 – LAN Environment, TCP/IP v. 01.01
TDAT138 – LogBook v. 01.00
TDAT300 – IPC Test v. 01.02
TDAT301 – IPC and beckhoff I/O v. 01.02
TDAT302 – IPC and PIU modules v. 01.01
6.10. TEST SCRIPT DOCUMENTS
TSCR028 – CtlExec Mapplication v. 01.00
TSCR100 – DatExec Mapplication v. 01.00
TSCR104 – Workbench Mapplication v. 01.01
TSCR300 – IPC9XX Automatic test v. 01.03
TSCR301 – IPC and Beckhoff I/O v. 01.02
6.11. TEST PLANS
TPLA072 – Component Integration Test Plan before CBAS001 v. 04.03 v. 01.00
TPLA073 – System Test Plan before CBAS001 v. 04.03 v. 01.00
6.12. TEST REPORTS
TREP072 – Component Integration Test Plan before CBAS001 v. 04.03 v. 01.00
TREP073 – System Test Plan before CBAS001 v. 04.03 v. 01.01
PROCOS Release Specification Page 21 of 36
Document ID: CBAS001 Version: 04.03 Date: 2013-10-24
File: CBAS001_v04-03 ReleaseSpec
6.13. TRACEABILITY MATRIX
RTM_005 – Traceability Matrix, CBAS001 v. 04.03 v. 01.00
Page 22 of 36 PROCOS Release Specification
Date: 2013-10-24 Document ID: CBAS001 Version: 04.03
File: CBAS001_v04-03 ReleaseSpec
(Blank page)
PROCOS Release Specification Page 23 of 36
Document ID: CBAS001 Version: 04.03 Date: 2013-10-24
File: CBAS001_v04-03 ReleaseSpec
7. PROCOS BASIS
This chapter describes the Customer Baseline basis for delivering PROCOS to customers.
7.1. DEVELOPER TOOLS
The following tools are used for developing PROCOS:
MS Visual Studio.net 2005 version 8.0.50727.
MS Visual Studio 2010, version 10.0.40219
FairCom's c-tree version 6.0E.
CINCOM's ObjectStudio version 7.1.2.
Oracle Call Interfaces version 9.2.0.1.0.
InstallShield Professional version 7.01.
Crystal Reports XI Release 2.
POSIX Threads for Win32 library 'Pthreads-win32 version 2.7.02'.
ZedGraph version 5.15.
LightOPC OPC Server Toolkit version 0.888.0313
The following tools are used developing PROCOS IPC (on QNX platform):
Ipc9xx: QNX 6.1.0, qcc (gcc version 2.95.2).
Ipc5xx: QNX 6.3.2, qcc (gcc version 2.95.3).
7.2. OPERATING SYSTEM REQUIREMENTS
Please refer to USM_103 “Installation” User Manual for Windows, Ref. [1] and USM_125 “PROCOS Reporting”, Ref. [2].
7.3. DATABASE SYSTEM REQUIREMENTS
Oracle is used as the Database System.
PROCOS uses Oracle versions between and including 9.2.0.1.0 and 11gR2.
7.4. SENTINEL DRIVER FOR DONGLES
This Customer Baseline is valid on Sentinel Driver for Dongles version 7.0.0, 7.4.2 and 7.6.1.
7.5. ESW PACKAGES AND IPC REQUIREMENTS
An ESW Package and the IPC version must have fulfilled the following tasks to be included in the Customer Baseline basis:
The ESW package version has been included in a formal Test.
The related User Manuals are updated according to the ESW Package functionality.
The IPC5xx and IPC911 have been included in a formal Test.
Page 24 of 36 PROCOS Release Specification
Date: 2013-10-24 Document ID: CBAS001 Version: 04.03
File: CBAS001_v04-03 ReleaseSpec
(Blank page)
PROCOS Release Specification Page 25 of 36
Document ID: CBAS001 Version: 04.03 Date: 2013-10-24
File: CBAS001_v04-03 ReleaseSpec
Appendix A Corrections since last Customer Baseline
The following table lists the functional errors that have been corrected and successfully retested and improvements that have been implemented in this Baseline:
Mapplication Description Classified as Importance Reference
(ILS)
AB KF2 Gwy Change Logica to CGI from Q1-2013 Other Nice-to-have 3508
Alarm Display Change Logica to CGI from Q1-2013 Other Nice-to-have 3508
ASCII I/O Gateway Change Logica to CGI from Q1-2013 Other Nice-to-have 3508
Barcode Access Control
Change Logica to CGI from Q1-2013 Other Nice-to-have 3508
Batch Executor Batexec: Recipe name case sensitive Error Medium 3378
Batch Executor Change Logica to CGI from Q1-2013 Other Nice-to-have 3508
Batch Executor BATEXEC: National chars. causes download error
Error Medium 3519
Batch Executor BAT-EXEC: Add missing BatchIds Change request Medium 3543
Batch Executor BAT-EXEC: Crashes during unload of recipe.
Error Low 3549
Batch Standard Pictures
Change Logica to CGI from Q1-2013 Other Nice-to-have 3508
Batch Tool Windows user integration (single sign-on) Change request Medium 3230
Batch Tool Change Logica to CGI from Q1-2013 Other Nice-to-have 3508
Collect Change Logica to CGI from Q1-2013 Other Nice-to-have 3508
Collect DB-IF: ColDataStatusView StatusTxt-column not correct.
Error Low 3550
Collect COLLECT sends overrun notify to DBIF every scan
Improvement suggestion
Low 3552
Controller Executor IPC: AON( MSG_ID ) Improvement suggestion
Medium 3233
Controller Executor Change Logica to CGI from Q1-2013 Other Nice-to-have 3508
Controller Executor Faster scan on Controller Executor Change request Low 3511
Controller Executor Problem using event based COLLECT groups on OPCGWY.
Error Low 3522
Controller Tool Windows user integration (single sign-on) Change request Medium 3230
Controller Tool IPC: AON( MSG_ID ) Improvement suggestion
Medium 3233
Controller Tool Change Logica to CGI from Q1-2013 Other Nice-to-have 3508
Page 26 of 36 PROCOS Release Specification
Date: 2013-10-24 Document ID: CBAS001 Version: 04.03
File: CBAS001_v04-03 ReleaseSpec
Mapplication Description Classified as Importance Reference
(ILS)
Controller Tool Faster scan on Controller Executor Change request Low 3511
Data Set Executor Change Logica to CGI from Q1-2013 Other Nice-to-have 3508
Data Set Executor DAT-EXEC: DataSet alarms Error Medium 3560
DB-IF Change Logica to CGI from Q1-2013 Other Nice-to-have 3508
DB-IF Cannot update DB-IF. Error Low 3551
DB-IF Data Archiving Change Logica to CGI from Q1-2013 Other Nice-to-have 3508
Demo Data SINEC H1 Simulator (Demo Data) cannot start.
Error Low 3469
Demo Data Change Logica to CGI from Q1-2013 Other Nice-to-have 3508
Engineering DB-IF Mimic "Set Value" P_PVRCNAP with update to END
Improvement suggestion
Nice-to-have 2407
Engineering DB-IF Change Logica to CGI from Q1-2013 Other Nice-to-have 3508
Engineering DB-IF EngDBIF: Partly Missing SEQ Code display
Error Low 3555
Engineering Tool PID user interface Change request Low 2010
Engineering Tool Windows user integration (single sign-on) Change request Medium 3230
Engineering Tool IPC: AON( MSG_ID ) Improvement suggestion
Medium 3233
Engineering Tool Std Diplay for AI Point: No info about filtering
Improvement suggestion
Low 3371
Engineering Tool PICTOOL: Limitation of Net MIMIC list Improvement suggestion
Low 3473
Engineering Tool EngTool: Cannot print more copies Error Low 3502
Engineering Tool SND/RCV controller improvement. Improvement suggestion
Low 3506
Engineering Tool Change Logica to CGI from Q1-2013 Other Nice-to-have 3508
Engineering Tool Ipc sequence code not executed Error Medium 3509
Engineering Tool Faster scan on Controller Executor Change request Low 3511
Engineering Tool Misleading error messages in SEQ compilation
Error Low 3512
Engineering Tool Extract in file version for CBA04.00 from new ENG database
Improvement suggestion
Low 3516
Engineering Tool Add <=, >=, and <> to SEQ for IPC and CTL-Exec
Improvement suggestion
Low 3520
PROCOS Release Specification Page 27 of 36
Document ID: CBAS001 Version: 04.03 Date: 2013-10-24
File: CBAS001_v04-03 ReleaseSpec
Mapplication Description Classified as Importance Reference
(ILS)
Engineering Tool EngTool: Wrong Reference Check Error Medium 3521
Engineering Tool ENGTOOL: Recipe download slow Error Medium 3523
Engineering Tool ENGTOOL: Cannot turn off "Alam Timestamp from IPC"
Error Low 3525
Engineering Tool ENG-TOOL baseline problem. Error Medium 3541
Engineering Tool Workbench: new KEY.DAT version nr Change request Medium 3542
ESign Tool Windows user integration (single sign-on) Change request Medium 3230
ESign Tool Change Logica to CGI from Q1-2013 Other Nice-to-have 3508
Gateway Tool Windows user integration (single sign-on) Change request Medium 3230
Gateway Tool Change Logica to CGI from Q1-2013 Other Nice-to-have 3508
IPC Engineering Tool PID user interface Change request Low 2010
IPC Engineering Tool Windows user integration (single sign-on) Change request Medium 3230
IPC Engineering Tool IPC: AON( MSG_ID ) Improvement suggestion
Medium 3233
IPC Engineering Tool Std Diplay for AI Point: No info about filtering
Improvement suggestion
Low 3371
IPC Engineering Tool SND/RCV controller improvement. Improvement suggestion
Low 3506
IPC Engineering Tool Change Logica to CGI from Q1-2013 Other Nice-to-have 3508
IPC Executor/IPC ipc <-> ipc communication Improvement suggestion
Low 2870
IPC Executor/IPC IPC: AON( MSG_ID ) Improvement suggestion
Medium 3233
IPC Executor/IPC SND/RCV controller improvement. Improvement suggestion
Low 3506
IPC Executor/IPC Change Logica to CGI from Q1-2013 Other Nice-to-have 3508
IPC Executor/IPC IPC: Remove the 10Mbit/s 'speedo'-parameter.
Change request Low 3527
IPC Executor/IPC Change priority of PIU-tasks in IPC Improvement suggestion
Low 3538
IPC Gateway ipc <-> ipc communication Improvement suggestion
Low 2870
IPC Gateway IPC: AON( MSG_ID ) Improvement suggestion
Medium 3233
IPC Gateway IPCGWY: Retransmission of old events Error Low 3499
Page 28 of 36 PROCOS Release Specification
Date: 2013-10-24 Document ID: CBAS001 Version: 04.03
File: CBAS001_v04-03 ReleaseSpec
Mapplication Description Classified as Importance Reference
(ILS)
IPC Gateway SND/RCV controller improvement. Improvement suggestion
Low 3506
IPC Gateway Change Logica to CGI from Q1-2013 Other Nice-to-have 3508
IPC Gateway DOf/DOm may cause IPCGWY to print errors in window.
Error Low 3536
IPC Gateway Workbench: new KEY.DAT version nr Change request Medium 3542
IPC Gateway IPCGWY shall send an alarm if IPC version is too old to handle
Change request Medium 3544
IPC Gateway Strange "... ObjEvnt ... codebyte..." message in IPCGWY window.
Error Low 3556
IPC Standard Pictures PID user interface Change request Low 2010
IPC Standard Pictures IPC: AON( MSG_ID ) Improvement suggestion
Medium 3233
IPC Standard Pictures Std Diplay for AI Point: No info about filtering
Improvement suggestion
Low 3371
IPC Standard Pictures SND/RCV controller improvement. Improvement suggestion
Low 3506
IPC Standard Pictures Change Logica to CGI from Q1-2013 Other Nice-to-have 3508
Log IPCGWY: Retransmission of old events Error Low 3499
Log SND/RCV controller improvement. Improvement suggestion
Low 3506
Log Change Logica to CGI from Q1-2013 Other Nice-to-have 3508
Log Log may terminate at startup because of corrupt *.idx file
Error Low 3517
Log LOG: Missing parameter name in LogDisplay
Error Medium 3537
Log AlarmDisp: Unable to Disable Alarm Error Medium 3554
Log Display Change Logica to CGI from Q1-2013 Other Nice-to-have 3508
LogBook Change Logica to CGI from Q1-2013 Other Nice-to-have 3508
MIMIC IPC: AON( MSG_ID ) Improvement suggestion
Medium 3233
MIMIC Std display for AlarmInfo on area show wrong no. in High/Not Ack.
Error Low 3490
MIMIC IPC Std pic. for SEQ error in view = Local name
Error Low 3496
MIMIC Change Logica to CGI from Q1-2013 Other Nice-to-have 3508
MIMIC Faster scan on Controller Executor Change request Low 3511
PROCOS Release Specification Page 29 of 36
Document ID: CBAS001 Version: 04.03 Date: 2013-10-24
File: CBAS001_v04-03 ReleaseSpec
Mapplication Description Classified as Importance Reference
(ILS)
MIMIC LogBook: Unexpected entry Error Medium 3524
MIMIC LogBook: Capability problem. Error Low 3530
MIMIC Workbench: new KEY.DAT version nr Change request Medium 3542
MIMIC EngTool: Profiles and MMS Variables Error Low 3558
Modbus Gateway Change Logica to CGI from Q1-2013 Other Nice-to-have 3508
OPC Client Gateway Change Logica to CGI from Q1-2013 Other Nice-to-have 3508
OPC Client Gateway Problem using event based COLLECT groups on OPCGWY.
Error Low 3522
OPC Server Change Logica to CGI from Q1-2013 Other Nice-to-have 3508
Oracle Supplement Change Logica to CGI from Q1-2013 Other Nice-to-have 3508
PIC-TOOL Windows user integration (single sign-on) Change request Medium 3230
PIC-TOOL Change Logica to CGI from Q1-2013 Other Nice-to-have 3508
PIC-TOOL PICTOOL extract generates different content of *.pic file
Error Medium 3546
Report Web Server Change Logica to CGI from Q1-2013 Other Nice-to-have 3508
Report Web Server Collect report does not handle more collect groups with same name
Error Low 3545
Siemens H1 Gateway Change Logica to CGI from Q1-2013 Other Nice-to-have 3508
SMS Tool Windows user integration (single sign-on) Change request Medium 3230
SMS Tool Change Logica to CGI from Q1-2013 Other Nice-to-have 3508
SPR-IF Change Logica to CGI from Q1-2013 Other Nice-to-have 3508
SQL Gateway SQLGWY: Add a trace including keys if no data found
Improvement suggestion
Medium 3486
SQL Gateway Change Logica to CGI from Q1-2013 Other Nice-to-have 3508
Token Access Control Change Logica to CGI from Q1-2013 Other Nice-to-have 3508
Trend Change Logica to CGI from Q1-2013 Other Nice-to-have 3508
TwinCAT Gateway Change Logica to CGI from Q1-2013 Other Nice-to-have 3508
User Access Control Windows user integration (single sign-on) Change request Medium 3230
Page 30 of 36 PROCOS Release Specification
Date: 2013-10-24 Document ID: CBAS001 Version: 04.03
File: CBAS001_v04-03 ReleaseSpec
Mapplication Description Classified as Importance Reference
(ILS)
User Access Control Change Logica to CGI from Q1-2013 Other Nice-to-have 3508
User Administration Tool
Windows user integration (single sign-on) Change request Medium 3230
User Administration Tool
Change Logica to CGI from Q1-2013 Other Nice-to-have 3508
User Administration Tool
UserLog fails, when extracting the Audit log.
Error Low 3533
Utilities Change Logica to CGI from Q1-2013 Other Nice-to-have 3508
Workbench Windows user integration (single sign-on) Change request Medium 3230
Workbench IPC: AON( MSG_ID ) Improvement suggestion
Medium 3233
Workbench ScreenCopy: Open File Change request Medium 3493
Workbench IPCGWY: Retransmission of old events Error Low 3499
Workbench OPC Gateway returns errorcode 3 on read. Error Low 3501
Workbench EngTool: Cannot print more copies Error Low 3502
Workbench Change Logica to CGI from Q1-2013 Other Nice-to-have 3508
Workbench ENGTOOL: Recipe download slow Error Medium 3523
Workbench LogBook: Unexpected entry Error Medium 3524
Workbench Setup: Printer(s) not listed in [Tools][Report]
Improvement suggestion
Nice-to-have 3532
Workbench Workbench: new KEY.DAT version nr Change request Medium 3542
Workbench AlarmDisp: Unable to Disable Alarm Error Medium 3554
Workbench EngTool: Profiles and MMS Variables Error Low 3558
PROCOS Release Specification Page 31 of 36
Document ID: CBAS001 Version: 04.03 Date: 2013-10-24
File: CBAS001_v04-03 ReleaseSpec
The following table lists the functional errors that have been removed from Appendix B, though not corrected, in this Baseline:
Mapplication/ Document
Description Classified as Impor-tance
Refe-rence
Cause of removal
IPCTool Comment on USM074 Improvement suggestion
Low 2416 USM correction only
Report Client In Setup Application the version no of the Report Client is shown as 6.00.2800. The correct version is 6.00.0100
Error Low 2663 USM correction only
SOP_605 Handling of non-PROCOS ILS
Error Low 2946 Procedure correction only
USM_131 Updates to USM_131: PROCOS Technical System Description
Improvement suggestion
Nice-to-have
3166 USM correction only
Batch Executor When the using the Data CleanUp feature not all data in Data\BatExec are cleared. All data shold be cleared
Error Low 3481 Cannot be reproduced
RTP_001 Review of RTM_004 revealed inconsistency in section 3.1.1 in RTP_001. Requirement Type "D" must have optional fill in of columns "Test spec.", "Test data", and "Procedure".
Error Low 3515 Procedure correction only
Log LOG does not close the Printer-Connection Error Low 3531 USM correction only
PIC-TOOL In a picture action it is not possible to CALL an action with a ':' in the name.
Error Low 3535 Will not correct
Page 32 of 36 PROCOS Release Specification
Date: 2013-10-24 Document ID: CBAS001 Version: 04.03
File: CBAS001_v04-03 ReleaseSpec
(Blank page)
PROCOS Release Specification Page 33 of 36
Document ID: CBAS001 Version: 04.03 Date: 2013-10-24
File: CBAS001_v04-03 ReleaseSpec
Appendix B Known Errors and Workarounds
This Customer Baseline contains some known errors that have not been corrected yet. For most errors workarounds have been established.
The following table lists known errors and workarounds:
Mappl. Description Classified
as Importance ILS No. Comments / Workarounds
IPC 911 IPC911 communication problem on PIU bus with 2-wire RS485
Error Low 2776, 2808 Change communication to half duplex
Workbench Invisible workbench menu bar.
Error Low 2828 Only when selecting “Show desktop”.
SINEC-H1 Gateway
No connection to Siemens PLC
Error Low 2849
Workbench Workbench crashes, when starting PicTool.
Error Low 3088 It seems to work if you start/stop other Mapplications before starting PicTool
Workbench Message on WIN7 if PROCOS "setup" is startet from "Programs"
Error Low 3283
PicTool PicTool: Texts size is changed
Error Medium 3352
IPC-9xx
Problem with "false" alarms on 4-20mA AI
Error Low 3364
User Adm. Tool
User Adm. Tool: Database installation problems after import
Error Medium 3376
Batch Executor
Batch: Wrong Procedure name.
Error Medium 3384
Mimic MIMIC locks Error Low 3404
Mimic MIMIC: Cannot use F10 as FastKey
Error Low 3429
Mimic MIMIC Std billede for CTL-EXEC
Error Low 3467
Mimic MIMIC: Small copy of MIMIC window in upper left corner of parent window
Error Low 3483
Collect COL_02014 logs invalid data. Error Medium 3504 Cannot be reproduced consistently
PicTool PICTOOL: Lines invisible Error Low 3513
Workbench
PROCOS cannot communicate, if the IP-addresses differ on the first 3 octets. E.g. if:
GWYxx = 10.1.0.x
ENGxx = 10.1.1.x
OPRxx = 10.1.2.x
ORAxx = 10.1.3.x
Error Low 3547 Choose other addresses
MIMIC
When using the Scroll Wheel on an Mimic picture, the picture does not always scroll up and down
Error Medium 3548
Page 34 of 36 PROCOS Release Specification
Date: 2013-10-24 Document ID: CBAS001 Version: 04.03
File: CBAS001_v04-03 ReleaseSpec
Mappl. Description Classified
as Importance ILS No. Comments / Workarounds
IPC The IPC does not generate any alarms upon startup, if it fails to initialize a PIU.
Error Low 3557
EngTool
Cannot merge profile. The profile was extracted from another database using EngTool v.6.05.0300, but the merge failed subsequently.
Error Medium 3559 The profile is in fact merged correctly – in spite of error messages displayed.
PROCOS Release Specification Page 35 of 36
Document ID: CBAS001 Version: 04.03 Date: 2013-10-24
File: CBAS001_v04-03 ReleaseSpec
Appendix C PIU EPROM for Process InterfaceModules
Preferred On-board firmware used on the PIU modules The tables below states the preferred version of the onboard firmware used on the process interface modules. The modules have been produced in two versions, the latest version was released between 1995-1998.
Please check that the PIU modules are upgrateded to a preferred version!
Process Interface Units based on the “old” two layer PCBs EPROM PIU 1125
PCB 0680 PIU 1165 PCB 0681
PIU 1166 PCB 0963
PIU 1225 PCB 0682
PIU 1236 PCB 06689
1068-01 (24 pin) Upgrade
1068-02 (24 pin) Upgrade
1068-03 (24 pin) Preferred
3270-01 (28 pin) ~ 1068-03 Preferred
1095-01 (24 pin) Upgrade
1095-02 (24 pin) Preferred
3271-01 (28 pin) ~ 1095-02 Preferred
1082-01 (24 pin) Upgrade
1082-02 (24 pin) Preferred
3272-01 (28 pin) ~ 1082-02 Preferred
1076-01 (24 pin) Upgrade
1076-02 (24 pin) Upgrade
2850-01 (24 pin) Upgrade
3273-01 (28 pin) ~ 2850-01 Upgrade
3273-02 (28 pin) Preferred
1070-01 (24 pin) Upgrade
1070-02 (24 pin) Upgrade
1070-03 (24 pin) Upgrade
3274-01 (28 pin) ~ 1070-03 Upgrade
1070-04 (28 pin) Upgrade
1070-05 (28 pin) Upgrade
1070-06 (28 pin) Preferred
Process Interface Units based on the “new” four layer PCBs EPROM PIU 1125
PCB 0020 PIU 1165 PCB 0021
PIU 1225 PCB 0023
PIU 1236 PCB 0019
3440-01 (28 pin) Not implemented Not implemented Not implemented Upgrade to newer
3440-02 (28 pin) Not implemented Not implemented Not implemented Upgrade to newer
3440-03 (28 pin) Not implemented Not implemented Not implemented Upgrade to newer
3440-04 (28 pin) Not implemented Not implemented Not implemented Upgrade to newer
3440-05 (28 pin) Not implemented Not implemented Not implemented Preferred
3440-06 (28 pin) Not implemented Not implemented Not implemented Preferred
3470-01 (28 pin) Upgrade to newer Upgrade to newer Not implemented Not implemented
3470-02 (28 pin) Upgrade to newer Upgrade to newer Upgrade to newer Not implemented
3470-03 (28 pin) Upgrade to newer Preferred Upgrade to newer Not implemented
3470-04 (28 pin) Upgrade to newer Preferred Upgrade to newer Not implemented
3470-05 (28 pin) Preferred Preferred Upgrade to newer Not implemented
3470-06 (28 pin) Preferred Preferred Preferred Not implemented
Page 36 of 36 PROCOS Release Specification
Date: 2013-10-24 Document ID: CBAS001 Version: 04.03
File: CBAS001_v04-03 ReleaseSpec
(Blank page)