2
Mon Sep 24 12:13:38 2001 Case: D:\Hysys\Curso\ICAFD\Material\Intermedio\Problemas\Prob 19\Prob 19.hsc Flowsheet: Case (Main) Main_1 Branch_1 Branch_4 Branch_3 Branch_2 Main_2 Main_3 Feed 1 Q_P-1 2 3 5 Q_P-2 4 Q_P-3 6 7 8 15 Q_P-4 12 Q_P-5 9 Q_P-6 10 11 Q_P-7 13 Main_4 14 Q_P-8 16 TEE-100 TEE-101 MIX-100 MIX-101 PROBLEMA_19  ADJ-1  A  ADJ-2 A  ADJ-3 A  ADJ-4 A PIPE DIAM LONG DELTA Z Main_1 8 in 5.0 millas 0 Main_2 8 in 5.0 millas 35 Main_3 8 in 5.0 millas 35 Main_4 8 in 2.5 millas 35 Branch_1 6 in 2.5 millas 30 Branch_2 4 in 2.5 millas 10 Branch_3 4 in 5.0 millas 40 Branch_4 4 in 10. millas 50 Estimados de Flujo Corriente 2 = 5.0 MMSCFD Corriente 6 = 1.0 MMSCFD Corriente 7 = 1.0 MMSCFD  ADJUSTS Tamaño de Paso  Ajuste del Flujo de 2 Hasta que la Presion de 4 = Presion de 9 0.5 MMSCFD  Ajuste del Flujo de 6 Hasta que la Presion de 14 = Presion de 15 0.5 MMSCFD  Ajuste del Flujo de 7 Hasta que la Presion de 11 = Presion de 12 0.5 MMSCFD  Ajuste de la Presion de Feed Hasta que la Presion de 16 = 500 Psia 50 Psia Todas las tolerancias son 0.5 Psi Todos los Adjust son Simultaneos Corriente Feed Temp. 120°F Presion 500 Psia (Estimado) Flujo 10.0 MMSCFD Comp. Fraccion Mol Metano 0.900 Etano 0.065 Propano 0.020 i-Butano 0.005 n-Butano 0.005 i-Pentano 0.002 n_pentano 0.002 Hehano 0.001 Temperatura Ambiente = 40°F Coef. de Transf. de Calor = 1.0 500 Psia MIX-102

Prob_19

Embed Size (px)

Citation preview

Page 1: Prob_19

7/21/2019 Prob_19

http://slidepdf.com/reader/full/prob19 1/1

Mon Sep 24 12:13:38 2001 Case: D:\Hysys\Curso\ICAFD\Material\Intermedio\Problemas\Prob_19\Prob_19.hsc Flowsheet: Case (Main)

Main_1

Branch_1

Branch_4

Branch_3

Branch_2Main_2

Main_3

Feed 1

Q_P-1

2

3

5

Q_P-2

4

Q_P-3

6

7

8

15

Q_P-4

12

Q_P-5

9

Q_P-6

10

11

Q_P-7

13

Main_4

14

Q_P-8

16

TEE-100TEE-101

MIX-100

MIX-101

PROBLEMA_19

 ADJ-1   A

 ADJ-2

A

 ADJ-3

A

 ADJ-4

A

PIPE DIAM LONG DELTA Z

Main_1 8 in 5.0 millas 0

Main_2 8 in 5.0 millas 35Main_3 8 in 5.0 millas 35Main_4 8 in 2.5 millas 35Branch_1 6 in 2.5 millas 30Branch_2 4 in 2.5 millas 10Branch_3 4 in 5.0 millas 40Branch_4 4 in 10. millas 50

Estimados de Flujo

Corriente 2 = 5.0 MMSCFDCorriente 6 = 1.0 MMSCFDCorriente 7 = 1.0 MMSCFD

 ADJUSTS Tamaño de Paso

 Ajuste del Flujo de 2 Hasta que la Presion de 4 = Presion de 9 0.5 MMSCFD Ajuste del Flujo de 6 Hasta que la Presion de 14 = Presion de 15 0.5 MMSCFD Ajuste del Flujo de 7 Hasta que la Presion de 11 = Presion de 12 0.5 MMSCFD Ajuste de la Presion de Feed Hasta que la Presion de 16 = 500 Psia 50 Psia

Todas las tolerancias son 0.5 PsiTodos los Adjust son Simultaneos

Corriente FeedTemp. 120°FPresion 500 Psia (Estimado)Flujo 10.0 MMSCFDComp. Fraccion Mol

Metano 0.900Etano 0.065Propano 0.020i-Butano 0.005n-Butano 0.005i-Pentano 0.002n_pentano 0.002Hehano 0.001

Temperatura Ambiente = 40°FCoef. de Transf. de Calor = 1.0

500 Psia

MIX-102