118
Options Guide - English PRIMERGY TX200 S6 Server Options Guide Edition July 2010

PRIMERGY TX200 S6 Server - Fujitsu Technology …manuals.ts.fujitsu.com/illustrated_spares/content/TX200_S6/pdf/og.pdf · The PRIMERGY TX200 S6 server is an Intel-based server for

Embed Size (px)

Citation preview

Page 1: PRIMERGY TX200 S6 Server - Fujitsu Technology …manuals.ts.fujitsu.com/illustrated_spares/content/TX200_S6/pdf/og.pdf · The PRIMERGY TX200 S6 server is an Intel-based server for

Options Guide - English

PRIMERGY TX200 S6Server Options Guide

Edition July 2010

Page 2: PRIMERGY TX200 S6 Server - Fujitsu Technology …manuals.ts.fujitsu.com/illustrated_spares/content/TX200_S6/pdf/og.pdf · The PRIMERGY TX200 S6 server is an Intel-based server for

Comments… Suggestions… Corrections…The User Documentation Department would like toknow your opinion of this manual. Your feedback helpsus optimize our documentation to suit your individual needs.

Feel free to send us your comments by e-mail to email: [email protected].

Certified documentation according to DIN EN ISO 9001:2000To ensure a consistently high quality standard anduser-friendliness, this documentation was created tomeet the regulations of a quality management system which complies with the requirements of the standardDIN EN ISO 9001:2008.

cognitas. Gesellschaft für Technik-Dokumentation mbHwww.cognitas.de

Copyright and TrademarksCopyright © 2010 Fujitsu Technology Solutions GmbH.

All rights reserved.Delivery subject to availability; right of technical modifications reserved.

All hardware and software names used are trademarks of their respective manufacturers.

– The contents of this manual may be revised without prior notice.

– Fujitsu assumes no liability for damages to third party copyrights or other rights arising from the use of any information in this manual.

– No part of this manual may be reproduced in any form without the prior written permission of Fujitsu.

Microsoft, Windows, Windows Server, and Hyper V are trademarks or registered trademarks of Microsoft Corporation in the USA and other countries.

Intel and Xeon are trademarks or registered trademarks of Intel Corporation or its subsidiaries in the USA and other countries.

Page 3: PRIMERGY TX200 S6 Server - Fujitsu Technology …manuals.ts.fujitsu.com/illustrated_spares/content/TX200_S6/pdf/og.pdf · The PRIMERGY TX200 S6 server is an Intel-based server for

TX200 S6 Options Guide

Before reading this manual

For your safety

This manual contains important information for safely and correctly using this product.

Carefully read the manual before using this product. Pay particular attention to the accompanying manual "Safety notes and other important information" and ensure these safety notes are understood before using the product. Keep this manual and the manual "Safety notes and other important information" in a safe place for easy reference while using this product.

Radio interference

This product is a "Class A" ITE (Information Technology Equipment). In a domestic environment this product may cause radio interference, in which case the user may be required to take appropriate measures. VCCI-A

Aluminum electrolytic capacitors

The aluminum electrolytic capacitors used in the product's printed circuit board assemblies and in the mouse and keyboard are limited-life components. Use of these components beyond their operating life may result in electrolyte leakage or depletion, potentially causing emission of foul odor or smoke.

As a guideline, in a normal office environment (25°C) operating life is not expected to be reached within the maintenance support period (5 years). However, operating life may be reached more quickly if, for example, the product is used in a hot environment. The customer shall bear the cost of replacing replaceable components which have exceeded their operating life. Note that these are only guidelines, and do not constitute a guarantee of trouble-free operation during the maintenance support period.

High safety use

This product has been designed and manufactured for general uses such as general office use, personal use, domestic use and normal industrial use. It has not been designed or manufactured for uses which demand an extremely high level of safety and carry a direct and serious risk to life or body if such safety cannot be ensured.

Page 4: PRIMERGY TX200 S6 Server - Fujitsu Technology …manuals.ts.fujitsu.com/illustrated_spares/content/TX200_S6/pdf/og.pdf · The PRIMERGY TX200 S6 server is an Intel-based server for

Options Guide TX200 S6

These uses include control of nuclear reactions in nuclear power plants, automatic airplane flight control, air traffic control, traffic control in mass transport systems, medical devices for life support, and missile guidance control in weapons systems (hereafter, "high safety use"). Customers should not use this product for high safety use unless measures are in place for ensuring the level of safety demanded of such use. Please consult the sales staff of Fujitsu if intending to use this product for high safety use.

Measures against momentary voltage drop

This product may be affected by a momentary voltage drop in the power supply caused by lightning. To prevent a momentary voltage drop, use of an AC uninterruptible power supply is recommended.

(This notice follows the guidelines of Voltage Dip Immunity of Personal Computer issued by JEITA, the Japan Electronics and Information Technology Industries Association.)

Technology controlled by the Foreign Exchange and Foreign Trade Control Law of Japan

Documents produced by Fujitsu may contain technology controlled by the Foreign Exchange and Foreign Trade Control Law of Japan. Documents which contain such technology should not be exported from Japan or transferred to non-residents of Japan without first obtaining authorization in accordance with the above law.

Harmonic Current Standards

This product conforms to harmonic current standard JIS C 61000-3-2.

Only for the Japanese market:About SATA hard disk drives

The SATA version of this server supports hard disk drives with SATA / BC-SATA storage interfaces. Please note that the usage and operation conditions differ depending on the type of hard disk drive used.

Please refer to the following internet address for further information on the usage and operation conditions of each available type of hard disk drive:

http://primeserver.fujitsu.com/primergy/harddisk/

Page 5: PRIMERGY TX200 S6 Server - Fujitsu Technology …manuals.ts.fujitsu.com/illustrated_spares/content/TX200_S6/pdf/og.pdf · The PRIMERGY TX200 S6 server is an Intel-based server for

TX200 S6 Options Guide

Only for the Japanese market:

Shielded LAN cables should be used in this product.

Only for the Japanese market:

I Although described in this manual, some sections do not apply to the Japanese market. These options and routines include:

– USB Flash Module (UFM)

– CSS (Customer Self Service)

– Conversion to hot-plug PS and redundant system fans

Page 6: PRIMERGY TX200 S6 Server - Fujitsu Technology …manuals.ts.fujitsu.com/illustrated_spares/content/TX200_S6/pdf/og.pdf · The PRIMERGY TX200 S6 server is an Intel-based server for

Options Guide TX200 S6

Page 7: PRIMERGY TX200 S6 Server - Fujitsu Technology …manuals.ts.fujitsu.com/illustrated_spares/content/TX200_S6/pdf/og.pdf · The PRIMERGY TX200 S6 server is an Intel-based server for

TX200 S6 Options Guide

Contents

1 Introduction . . . . . . . . . . . . . . . . . . . . . . . . . . . 11

1.1 Concept and target groups . . . . . . . . . . . . . . . . . . 11

1.2 Documentation overview . . . . . . . . . . . . . . . . . . . 11

1.3 Expansions and upgrades . . . . . . . . . . . . . . . . . . . 13

1.4 Notational conventions . . . . . . . . . . . . . . . . . . . . 15

2 Procedure . . . . . . . . . . . . . . . . . . . . . . . . . . . . 17

3 Safety instructions . . . . . . . . . . . . . . . . . . . . . . . 19

4 Preparation . . . . . . . . . . . . . . . . . . . . . . . . . . . 27

4.1 Floorstand model . . . . . . . . . . . . . . . . . . . . . . . . 284.1.1 Opening the server . . . . . . . . . . . . . . . . . . . . . . . 284.1.2 Removing the front cover . . . . . . . . . . . . . . . . . . . . 29

4.2 Rack model . . . . . . . . . . . . . . . . . . . . . . . . . . . 304.2.1 Opening the server . . . . . . . . . . . . . . . . . . . . . . . 304.2.2 Removing the rack front cover . . . . . . . . . . . . . . . . . . 32

4.3 System fans . . . . . . . . . . . . . . . . . . . . . . . . . . . 334.3.1 Removing system fan 2 (or 2&4) . . . . . . . . . . . . . . . . 344.3.2 Removing system fan 1 (or 1&3) . . . . . . . . . . . . . . . . 35

5 Main memory . . . . . . . . . . . . . . . . . . . . . . . . . . 37

5.1 Memory modules . . . . . . . . . . . . . . . . . . . . . . . . 38

5.2 Expanding the main memory . . . . . . . . . . . . . . . . . 39

6 Processors . . . . . . . . . . . . . . . . . . . . . . . . . . . 41

6.1 Installing a second processor . . . . . . . . . . . . . . . . . 42

Page 8: PRIMERGY TX200 S6 Server - Fujitsu Technology …manuals.ts.fujitsu.com/illustrated_spares/content/TX200_S6/pdf/og.pdf · The PRIMERGY TX200 S6 server is an Intel-based server for

Options Guide TX200 S6

Contents

6.2 Replacing the processor . . . . . . . . . . . . . . . . . . . . 48

6.3 Replacing the heat sink . . . . . . . . . . . . . . . . . . . . . 50

7 Accessible drives and LSD/LSP . . . . . . . . . . . . . . . . 51

7.1 Equipping of the bays . . . . . . . . . . . . . . . . . . . . . . 52

7.2 Installing an accessible 5.25-inch drive . . . . . . . . . . . . 54

7.3 Installing the multibay . . . . . . . . . . . . . . . . . . . . . . 58

7.4 Installing the hard disks extension box . . . . . . . . . . . . 64

8 Expansion cards and BBU . . . . . . . . . . . . . . . . . . . 73

8.1 Installing expansion cards . . . . . . . . . . . . . . . . . . . 73

8.2 Installing a BBU . . . . . . . . . . . . . . . . . . . . . . . . . 77

9 Further options . . . . . . . . . . . . . . . . . . . . . . . . . 81

9.1 TPM . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 81

9.2 USB Flash Module (UFM) . . . . . . . . . . . . . . . . . . . . 83

9.3 Second serial connector . . . . . . . . . . . . . . . . . . . . 85

10 Conversion to hot-plug PS and redundant system fans . . . 87

11 Conversion from a floorstand model to a rack model . . . . . 95

12 Completion . . . . . . . . . . . . . . . . . . . . . . . . . . . 101

12.1 System fans . . . . . . . . . . . . . . . . . . . . . . . . . . 10112.1.1 Installing system fan 1 (or 1&3) . . . . . . . . . . . . . . . . . 10112.1.2 Installing system fan 2 (or 2&4) . . . . . . . . . . . . . . . . . 102

12.2 Floorstand model . . . . . . . . . . . . . . . . . . . . . . . 10312.2.1 Attaching the front cover . . . . . . . . . . . . . . . . . . . . 10312.2.2 Closing the server . . . . . . . . . . . . . . . . . . . . . . . . 104

Page 9: PRIMERGY TX200 S6 Server - Fujitsu Technology …manuals.ts.fujitsu.com/illustrated_spares/content/TX200_S6/pdf/og.pdf · The PRIMERGY TX200 S6 server is an Intel-based server for

TX200 S6 Options Guide

Contents

12.3 Rack model . . . . . . . . . . . . . . . . . . . . . . . . . . . 10512.3.1 Attaching the rack front cover . . . . . . . . . . . . . . . . . . 10512.3.2 Closing the server . . . . . . . . . . . . . . . . . . . . . . . . 106

13 Appendix . . . . . . . . . . . . . . . . . . . . . . . . . . . . 109

13.1 Cabling . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 109

Index . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 117

Page 10: PRIMERGY TX200 S6 Server - Fujitsu Technology …manuals.ts.fujitsu.com/illustrated_spares/content/TX200_S6/pdf/og.pdf · The PRIMERGY TX200 S6 server is an Intel-based server for

Options Guide TX200 S6

Contents

Page 11: PRIMERGY TX200 S6 Server - Fujitsu Technology …manuals.ts.fujitsu.com/illustrated_spares/content/TX200_S6/pdf/og.pdf · The PRIMERGY TX200 S6 server is an Intel-based server for

TX200 S6 Options Guide 11

1 IntroductionThe PRIMERGY TX200 S6 server is an Intel-based server for mid-size and large companies. The server is suitable for use as a file server and also as an application, information or Internet server. It is available as a floorstand or rack model. The floorstand model can be converted to a rack model using an optional conversion kit.

1.1 Concept and target groups

This Options Guide shows you how to extend and upgrade your server.

V CAUTION!

The activities described in this manual may only be performed by technical specialists.

I The installation and removal of the hot-plug components is described in the Operating Manual supplied with the server.

1.2 Documentation overview

More information on your PRIMERGY TX200 S6 can be found in the following documents:

– "Quick Start Hardware - PRIMERGY TX200 S6" leaflet " はじめにお読みください -PRIMERGY TX200 S6" for the Japanese market(only included as a printed copy)

– "Quick Start Software - Quick Installation Guide" DVD booklet (only included with the ServerView Suite as a printed copy) except for the Japanese market

– "Safety notes and other important information" manual" 安全上の注意およびその他の重要情報 " for the Japanese market

– "Warranty" manual" 保証書 " for the Japanese market

– "ServerView Suite Local Service Concept - LSC" manual

– "Returning used devices" manual and "Service Desk" leaflet" サポート&サービス " for the Japanese market

Page 12: PRIMERGY TX200 S6 Server - Fujitsu Technology …manuals.ts.fujitsu.com/illustrated_spares/content/TX200_S6/pdf/og.pdf · The PRIMERGY TX200 S6 server is an Intel-based server for

12 Options Guide TX200 S6

Introduction

– "PRIMERGY TX200 S6 Server Operating Manual"

– "PRIMERGY TX200 S6 Server Options Guide"

– "System Board D2799 for PRIMERGY TX200 S6 Technical Manual"

– "D2799 BIOS Setup Utility for TX200 S6" manual

I PRIMERGY manuals are available in PDF format on the ServerView Suite DVD 2. The ServerView Suite DVD 2 is part of the ServerView Suite supplied with every server.

If you no longer have the ServerView Suite DVDs, you can obtain the relevant current versions using the order number U15000-C289 (the order number for the Japanese market: please refer to the configurator of the server http://primeserver.fujitsu.com/primergy/system.html).

The PDF files of the manuals can also be downloaded free of charge from the Internet. The overview page showing the online documentation available on the Internet can be found using the URL (for EMEA market): http://manuals.ts.fujitsu.com. The PRIMERGY server documentation can be accessed using the Industry standard servers navigation option.

For the Japanese market please use the URL: http://primeserver.fujitsu.com/primergy/manual.html.

Further sources of information:

– PRIMERGY Abbreviations and Glossary on the ServerView Suite DVD 2– Manual for the monitor– Documentation for the boards and drives– Operating system documentation– Information files in your operating system

Page 13: PRIMERGY TX200 S6 Server - Fujitsu Technology …manuals.ts.fujitsu.com/illustrated_spares/content/TX200_S6/pdf/og.pdf · The PRIMERGY TX200 S6 server is an Intel-based server for

TX200 S6 Options Guide 13

Introduction

1.3 Expansions and upgrades

Main memory

12 slots (6 slots per CPU) are available for the main memory. The slots can be equipped with RDIMMs (registered DIMM, capacities: 2, 4 and 8 GB) or with UDIMM (unbuffered DIMM, capacities: 1 and 2 GB) memory modules. A combination of both module types is not allowed.

Second processor

The system board can be upgraded with a second processor. Only processors of the same type may be used on the system board. That means the number of the internal processor cores as well as the primary clock and the FSB frequency have to be the same.

Accessible drives

Three 5.25-inch bays are available for accessible drives. In these bays you can install DVD drives, magnetic tape drives, a multibay (slimline DVD and ServerView Local Service Panel/ServerView Local Service Display) or an HDD extension box.

ServerView Local Service Panel / ServerView Local Service Display

The system board supports the CSS (Customer Self Service) functionality (description see the operating manual). You can install a ServerView Local Service Panel (LSP) or a ServerView Local Service Display (LSD) for easier identification of the defective components.

HDD extension box

Two 5.25-inch bays for accessible drives can be used to install an HDD extension box.

Two variants of the HDD extension box are available:

– Variant 1:one bay for a LSP/LSD, one bay for a slimline DVD drive and two bays for 3.5-inch SAS/SATA HDD modules

– Variant 2:eight bays for 2.5-inch SAS/SATA HDD modules

Page 14: PRIMERGY TX200 S6 Server - Fujitsu Technology …manuals.ts.fujitsu.com/illustrated_spares/content/TX200_S6/pdf/og.pdf · The PRIMERGY TX200 S6 server is an Intel-based server for

14 Options Guide TX200 S6

Introduction

Additional expansion cards in the PCI slots

The system board offers six PCI slots:

– 5 x PCIe slots, all mechanical x8:– 2x PCIe x8 slots (Gen2), one slot is open on the right side to allow a x16

graphics card to be inserted– 2x PCIe x4 slots (Gen2)– 1x PCIe x4 slot (Gen1)

– 1 x PCI slot (32 bit / 33 MHz)

Trusted Platform Module (TPM)

The server can be equipped with a TPM (Trusted Platform Module). This module enables programs from third party manufacturers to store key information.

USB Flash Module (UFM)

The server can be equipped with a USB Flash Module (UFM).

This module can be used as optional memory for software (e.g. VMware) or as a software dongle.

Second serial connector

As an option, a second serial connector can be provided.

Conversion of standard power supply to hot-plug power supply and standard system fans to redundant system fans

The standard power supply can be replaced by a hot-plug power supply. The hot-plug power supply consists of two power supply modules.

If one power supply module fails, the other power supply module guarantees the unrestricted operation and the defective power supply module can be replaced while the system is operating (hot-plug).

The standard system fans can be upgraded to redundant system fans. If the redundant system fans are installed, the fans are operating in a redundant configuration. A defective system fan can be replaced during the next service.

Conversion from a floorstand model to a rack model

The floorstand model can be optionally converted to allow the server to be installed into any typical rack systems.

Page 15: PRIMERGY TX200 S6 Server - Fujitsu Technology …manuals.ts.fujitsu.com/illustrated_spares/content/TX200_S6/pdf/og.pdf · The PRIMERGY TX200 S6 server is an Intel-based server for

TX200 S6 Options Guide 15

Introduction

1.4 Notational conventions

The following notational conventions are used in this manual:

Text in italics indicates commands or menu items.

"Quotation marks" indicate names of chapters and terms that are being emphasized.

Ê describes activities that must be performed in the order shown.

V CAUTION! pay particular attention to texts marked with this symbol. Failure to observe this warning may endanger your life, destroy the system or lead to the loss of data.

I indicates additional information, notes and tips.

Page 16: PRIMERGY TX200 S6 Server - Fujitsu Technology …manuals.ts.fujitsu.com/illustrated_spares/content/TX200_S6/pdf/og.pdf · The PRIMERGY TX200 S6 server is an Intel-based server for

16 Options Guide TX200 S6

Introduction

Page 17: PRIMERGY TX200 S6 Server - Fujitsu Technology …manuals.ts.fujitsu.com/illustrated_spares/content/TX200_S6/pdf/og.pdf · The PRIMERGY TX200 S6 server is an Intel-based server for

TX200 S6 Options Guide 17

2 ProcedureV CAUTION!

● The actions described in this manual shall be performed by technical specialists. A technical specialist is a person who is trained to install the server including hardware and software.

● Repairs to the device that do not relate to CSS failures shall be performed by service personnel. Please note that unauthorized interference with the system will void the warranty and exempt the manufacturer from all liability.

● Any failure to observe the guidelines in this manual, and any improper repairs could expose the user to risks (electric shock, energy hazards, fire hazards) or damage the equipment.

Ê First of all, carefully read the safety instructions in the chapter "Safety instructions" on page 19.

Ê Make sure that all necessary manuals (see the section "Documentation overview" on page 11) are available; print the PDF files if required. Most importantly, you will need the Operating Manual for the server and the Technical Manual for the system board.

Ê Shut the server down correctly, switch it off, disconnect the power cords and open the server as described in the chapter "Preparation" on page 27.

Ê Carry out the expansion or upgrade of your server as described in the pertinent chapter.

I Installation and removal of the hot-plug components are described in the Operating Manual.

Ê Close the server, connect it to the power outlet, and switch it on as described in the chapter "Completion" on page 101.

Ê Start the operating system and make the appropriate configuration if necessary (see the Operating Manual).

I For the latest information on optional products provided for the TX200 S6 see the configurator of the server: https://sp.ts.fujitsu.com/dmsp/docs/cnfgtx200s6.pdf(for the EMEA market)http://primeserver.fujitsu.com/primergy/system.html (for the Japanese market)

Page 18: PRIMERGY TX200 S6 Server - Fujitsu Technology …manuals.ts.fujitsu.com/illustrated_spares/content/TX200_S6/pdf/og.pdf · The PRIMERGY TX200 S6 server is an Intel-based server for

18 Options Guide TX200 S6

Procedure

Page 19: PRIMERGY TX200 S6 Server - Fujitsu Technology …manuals.ts.fujitsu.com/illustrated_spares/content/TX200_S6/pdf/og.pdf · The PRIMERGY TX200 S6 server is an Intel-based server for

TX200 S6 Options Guide 19

3 Safety instructionsI The following safety instructions are also provided in the manual "Safety

notes and other important information".

This device meets the relevant safety regulations for IT equipment. If you have any questions about whether you can install the server in the intended environment, please contact your sales outlet or our customer service team.

V CAUTION!

● The actions described in this manual shall be performed by technical specialists. A technical specialist is a person who is trained to install the server including hardware and software.

● Repairs to the device that do not relate to CSS failures shall be performed by service personnel. Please note that unauthorized interference with the system will void the warranty and exempt the manufacturer from all liability.

● Any failure to observe the guidelines in this manual, and any improper repairs could expose the user to risks (electric shock, energy hazards, fire hazards) or damage the equipment.

● Before installing/removing internal options to/from the server, turn off the server, all peripheral devices, and any other connected devices. Also unplug all power cords from the power outlet. Failure to do so can cause electric shock.

V CAUTION!

● For safety reasons (danger of tipping) an anti-tilt bracket must be mounted on the rear side of floorstand models with hot-plug power supply.

Page 20: PRIMERGY TX200 S6 Server - Fujitsu Technology …manuals.ts.fujitsu.com/illustrated_spares/content/TX200_S6/pdf/og.pdf · The PRIMERGY TX200 S6 server is an Intel-based server for

20 Options Guide TX200 S6

Safety instructions

Before starting up

V CAUTION!

● During installation and before operating the device, observe the instructions on environmental conditions for your device.

● If the device is brought in from a cold environment, condensation may form both inside and on the outside of the device.

Wait until the device has acclimatized to room temperature and is absolutely dry before starting it up. Material damage may be caused to the device if this requirement is not observed.

● Transport the device only in the original packaging or in packaging that protects it from knocks and jolts.

Installation and operation

V CAUTION!

● This unit should not be operated in ambient temperatures above 35 °C.

● If the unit is integrated into an installation that draws power from an industrial power supply network with an IEC309 connector, the power supply's fuse protection must comply with the requirements for non-industrial power supply networks for type A connectors.

● The unit automatically adjusts itself to a mains voltage in a range of 100 V - 240 V. Ensure that the local mains voltage lies within these limits.

● This device must only be connected to properly grounded power outlets or insulated sockets of the rack's internal power supply with tested and approved power cords.

● Ensure that the device is connected to a properly grounded power outlet close to the device.

Page 21: PRIMERGY TX200 S6 Server - Fujitsu Technology …manuals.ts.fujitsu.com/illustrated_spares/content/TX200_S6/pdf/og.pdf · The PRIMERGY TX200 S6 server is an Intel-based server for

TX200 S6 Options Guide 21

Safety instructions

V CAUTION!

● Ensure that the power sockets on the device and the properly grounded power outlets are freely accessible.

● The On/Off button or the main power switch (if present) does not isolate the device from the mains power supply. To disconnect it completely from the mains power supply, unplug all network power plugs from the properly grounded power outlets.

● Always connect the server and the attached peripherals to the same power circuit. Otherwise you run the risk of losing data if, for example, the server is still running but a peripheral device (e.g. memory subsystem) fails during a power outage.

● Data cables must be adequately shielded.

● Ethernet cabling has to comply with EN 50173 and EN 50174-1/2 standards or ISO/IEC 11801 standard respectively. The minimum requirement is a Category 5 shielded cable for 10/100 Ethernet, or a Category 5e cable for Gigabit Ethernet.

● Route the cables in such a way that they do not create a potential hazard (make sure no-one can trip over them) and that they cannot be damaged. When connecting the server, refer to the relevant instructions in this manual.

● Never connect or disconnect data transmission lines during a storm (risk of lightning hazard).

● Make sure that no objects (e.g. jewelry, paperclips etc.) or liquids can get inside the server (risk of electric shock, short circuit).

● In emergencies (e.g. damaged casing, controls or cables, penetration of liquids or foreign bodies), switch off the server immediately, remove all power plugs and contact your sales outlet or customer service team.

Page 22: PRIMERGY TX200 S6 Server - Fujitsu Technology …manuals.ts.fujitsu.com/illustrated_spares/content/TX200_S6/pdf/og.pdf · The PRIMERGY TX200 S6 server is an Intel-based server for

22 Options Guide TX200 S6

Safety instructions

V CAUTION!

● Proper operation of the system (in accordance with IEC 60950-1/2 resp. EN 60950-1/2) is only ensured if the casing is completely assembled and the rear covers for the installation slots have been fitted (electric shock, cooling, fire protection, interference suppression).

● Only install system expansions that satisfy the requirements and rules governing safety and electromagnetic compatibility and those relating to telecommunication terminals. If you install other expansions, they may damage the system or violate the safety regulations. Information on which system expansions are approved for installation can be obtained from our customer service center or your sales outlet.

● The components marked with a warning notice (e.g. lightning symbol) may only be opened, removed or exchanged by authorized, qualified personnel. Exception: CSS components can be replaced.

● The warranty is void if the server is damaged during installation or replacement of system expansions.

● Only set screen resolutions and refresh rates that are specified in the operating manual for the monitor. Otherwise, you may damage your monitor. If you are in any doubt, contact your sales outlet or customer service center.

● Before installing/removing internal options to/from the server, turn off the server, all peripheral devices, and any other connected devices. Also unplug all power cords from the outlet. Failure to do so can cause electric shock.

● Do not damage or modify internal cables or devices. Doing so may cause a device failure, fire, or electric shock.

● Devices inside the server remain hot after shutdown. Wait for a while after shutdown before installing or removing internal options.

● The circuit boards and soldered parts of internal options are exposed and can be damaged by static electricity. Before handling them, first touch a metal part of the server to discharge static electricity from your body.

● Do not touch the circuitry on boards or soldered parts. Hold the metallic areas or the edges of the circuit boards.

Page 23: PRIMERGY TX200 S6 Server - Fujitsu Technology …manuals.ts.fujitsu.com/illustrated_spares/content/TX200_S6/pdf/og.pdf · The PRIMERGY TX200 S6 server is an Intel-based server for

TX200 S6 Options Guide 23

Safety instructions

V CAUTION!

● Install the screw removed during installation/detaching Internal Options in former device/position. To use a screw of the different kind causes a breakdown of equipment.

● The installation indicated on this note is sometimes changed to the kind of possible options without notice.

Batteries

V CAUTION!

● Incorrect replacement of batteries may result in a risk of explosion. The batteries may only be replaced with identical batteries or with a type recommended by the manufacturer (see the Technical Manual for the system board).

● Replace the lithium battery on the system board in accordance with the instructions in the Technical Manual for the system board.

Page 24: PRIMERGY TX200 S6 Server - Fujitsu Technology …manuals.ts.fujitsu.com/illustrated_spares/content/TX200_S6/pdf/og.pdf · The PRIMERGY TX200 S6 server is an Intel-based server for

24 Options Guide TX200 S6

Safety instructions

Working with CDs/DVDs/BDs and optical drives

When working with devices with optical drives, these instructions must be followed.

V CAUTION!

● Only use CDs/DVDs/BDs that are in perfect condition, in order to prevent data loss, equipment damage and injury.

● Check each CD/DVD/BD for damage, cracks, breakages etc. before inserting it in the drive.

Note that any additional labels applied may change the mechanical properties of a CD/DVD/BD and cause imbalance.

Damaged and imbalanced CDs/DVDs/BDs can break at high drive speeds (data loss).

Under certain circumstances, sharp CD/DVD/BD fragments can pierce the cover of the optical drive (equipment damage) and can fly out of the device (danger of injury, particularly to uncovered body parts such as the face or neck).

● High humidity and airborne dust levels are to be avoided. Electric shocks and/or server failures may be caused by liquids such as water, or metallic items, such as paper clips, entering a drive.

● Shocks and vibrations are also to be avoided.

● Do not insert any objects other than the specified CDs/DVDs/BDs.

● Do not pull on, press hard, or otherwise handle the CD/DVD/BD tray roughly.

● Do not disassemble the optical drive.

● Before use, clean the optical disk tray using a soft, dry cloth.

● As a precaution, remove disks from the optical drive when the drive is not to be used for a long time. Keep the optical disk tray closed to prevent foreign matter, such as dust, from entering the optical drive.

● Hold CDs/DVDs/BDs by their edges to avoid contact with the disk surface.

Page 25: PRIMERGY TX200 S6 Server - Fujitsu Technology …manuals.ts.fujitsu.com/illustrated_spares/content/TX200_S6/pdf/og.pdf · The PRIMERGY TX200 S6 server is an Intel-based server for

TX200 S6 Options Guide 25

Safety instructions

● Do not contaminate the CD/DVD/BD surface with fingerprints, oil, dust, etc. If dirty, clean with a soft, dry cloth, wiping from the center to the edge. Do not use benzene, thinners, water, record sprays, antistatic agents, or silicone-impregnated cloth.

● Be careful not to damage the CD/DVD/BD surface.

● Keep the CDs/DVDs/BDs away from heat sources.

● Do not bend or place heavy objects on CDs/DVDs/BDs.

● Do not write with ballpoint pen or pencil on the label (printed) side.

● Do not attach stickers or similar to the label side. Doing so may cause rotational eccentricity and abnormal vibrations.

● When a CD/DVD/BD is moved from a cold place to a warm place, moisture condensation on the CD/DVD/BD surface can cause data read errors. In this case, wipe the CD/DVD/BD with a soft, dry cloth then let it air dry. Do not dry the CD/DVD/BD using devices such as a hair dryer.

● To avoid dust, damage, and deformation, keep the CD/DVD/BD in its case whenever it is not in use.

● Do not store CDs/DVDs/BDs at high temperatures. Areas exposed to prolonged direct sunlight or near heating appliances are to be avoided.

I You can prevent damage from the optical drive and the CDs/DVDs/BDs, as well as premature wear of the disks, by observing the following suggestions:

– Only insert disks in the drive when needed and remove them after use.

– Store the disks in suitable sleeves.– Protect the disks from exposure to heat and direct sunlight.

Laser information

The optical drive complies with IEC 60825-1 laser class 1.

V CAUTION!

The optical drive contains a light-emitting diode (LED), which under certain circumstances produces a laser beam stronger than laser class 1. Looking directly at this beam is dangerous.

Never remove parts of the optical drive casing!

Page 26: PRIMERGY TX200 S6 Server - Fujitsu Technology …manuals.ts.fujitsu.com/illustrated_spares/content/TX200_S6/pdf/og.pdf · The PRIMERGY TX200 S6 server is an Intel-based server for

26 Options Guide TX200 S6

Safety instructions

Modules with Electrostatic-Sensitive Devices

Modules with electrostatic-sensitive devices are identified by the following sticker:

Figure 1: ESD label

When you handle components fitted with ESDs, you must always observe the following points:

● Switch off the system and remove the power plugs from the power outlets before installing or removing components with ESDs.

● You must always discharge static build-up (e.g. by touching a grounded object) before working with such components.

● Any devices or tools that are used must be free of electrostatic charge.

● Wear a suitable grounding cable that connects you to the external chassis of the system unit.

● Always hold components with ESDs at the edges or at the points marked green (touch points).

● Do not touch any connectors or conduction paths on an ESD.

● Place all the components on a pad which is free of electrostatic charge.

I For a detailed description of how to handle ESD components, see the relevant European or international standards (EN 61340-5-1, ANSI/ESD S20.20).

Page 27: PRIMERGY TX200 S6 Server - Fujitsu Technology …manuals.ts.fujitsu.com/illustrated_spares/content/TX200_S6/pdf/og.pdf · The PRIMERGY TX200 S6 server is an Intel-based server for

TX200 S6 Options Guide 27

4 PreparationV CAUTION!

● Before removing or attaching covers, turn off the server, all peripheral devices, and any other connected devices. Also unplug all power cords from the power outlet. Failure to do so can cause electric shock.

● Only for rack model:Use the anti-tilt plate to prevent the rack from tipping when installing the rack. Pulling the server out of the rack without having installed the anti-tilt plate may cause the rack to tip over.

● Only for rack model:Be careful not to pinch fingers or clothes when sliding out the server or pushing it back. Failure to do so may cause injury.

● Before attaching the cover, make sure no unnecessary parts or tools are left inside the server.

● Before turning on the server, make sure the cover is closed.

● Follow the safety instructions in the chapter "Safety instructions" on page 19.

Page 28: PRIMERGY TX200 S6 Server - Fujitsu Technology …manuals.ts.fujitsu.com/illustrated_spares/content/TX200_S6/pdf/og.pdf · The PRIMERGY TX200 S6 server is an Intel-based server for

28 Options Guide TX200 S6

Preparation

4.1 Floorstand model

4.1.1 Opening the server

Ê Terminate all applications and shut down the server correctly.

Ê If your operating system has not switched off the server, press the On/Off button.

Ê Pull all power cords out of the power outlet.

Ê Unlock the server and remove the key.

Figure 2: Opening the server

Ê Pull the locking lever as far as it will go (1). This pushes the side cover backward (2).

Ê Remove the side cover (3).

Page 29: PRIMERGY TX200 S6 Server - Fujitsu Technology …manuals.ts.fujitsu.com/illustrated_spares/content/TX200_S6/pdf/og.pdf · The PRIMERGY TX200 S6 server is an Intel-based server for

TX200 S6 Options Guide 29

Preparation

4.1.2 Removing the front cover

Remove the front cover when making the following routines:

– Installing/removing accessible drives– Conversion from a floorstand model to a rack model

Figure 3: Removing the front cover

Ê Release the three locks and open the front cover.

Ê Carefully unhook the front cover at the other side and remove the front cover.

Page 30: PRIMERGY TX200 S6 Server - Fujitsu Technology …manuals.ts.fujitsu.com/illustrated_spares/content/TX200_S6/pdf/og.pdf · The PRIMERGY TX200 S6 server is an Intel-based server for

30 Options Guide TX200 S6

Preparation

4.2 Rack model

Ê Terminate all applications and shut down the server correctly.

Ê If your operating system has not switched off the server, press the On/Off button.

Ê Pull all power cords out of the power outlet.

4.2.1 Opening the server

Pulling the server out of the rack and opening the server

Figure 4: Pulling the server out of the rack

Ê Loosen the two knurled screws (1) and pull the server as far as possible out of the rack (2).

Ê Pull the locking lever as far as it will go (see also figure 2 on page 28). This pushes the top cover backward.

V CAUTION!

Do not use the pulled-out server as a surface on which to put things or as a work surface, and strictly avoid leaning on or against it.

Ê Remove the top cover.

Page 31: PRIMERGY TX200 S6 Server - Fujitsu Technology …manuals.ts.fujitsu.com/illustrated_spares/content/TX200_S6/pdf/og.pdf · The PRIMERGY TX200 S6 server is an Intel-based server for

TX200 S6 Options Guide 31

Preparation

Removing the server from the rack and opening the server

Remove the server from the rack cabinet, if it is not sufficiently accessible.

I Removing the server from the rack may be different. In this case you will find the description in the packaging of the rack mounting kit.

Ê Disconnect all cables on the rear side of the server.

V CAUTION!

At least two people are needed to lift the server out of the rack cabinet.

Ê Loosen the two knurled screws on the front (see figure 4 on page 30) and pull the server as far as it will go out of the rack.

Figure 5: Unlocking the server and lifting it out of the rails

Ê Pull the locking bar forward on both sides (1).

Ê Lift the server out of the rails (2) and place it on a table, for example.

Ê Pull the locking lever as far as it will go (see also figure 2 on page 28). This pushes the top cover backward.

Ê Remove the top cover.

Page 32: PRIMERGY TX200 S6 Server - Fujitsu Technology …manuals.ts.fujitsu.com/illustrated_spares/content/TX200_S6/pdf/og.pdf · The PRIMERGY TX200 S6 server is an Intel-based server for

32 Options Guide TX200 S6

Preparation

4.2.2 Removing the rack front cover

You remove the rack front cover when making the following routines:

– Installing/removing accessible drives

Figure 6: Removing the rack front cover

Ê Remove two screws on either side (1).

Ê Remove the rack front cover to the front together with the plastic cover (2).

Page 33: PRIMERGY TX200 S6 Server - Fujitsu Technology …manuals.ts.fujitsu.com/illustrated_spares/content/TX200_S6/pdf/og.pdf · The PRIMERGY TX200 S6 server is an Intel-based server for

TX200 S6 Options Guide 33

Preparation

4.3 System fans

Figure 7: System fan 1 and system fan 1&3

The standard system fan 1 is shorter and has just one fan cable; the redundant system fan 1&3 (dual fan, two fans are integrated internally) is taller and has two fan cables. The procedure for removing both system fans is identical except for connecting the fan cables.

Figure 8: System fan 2 and system fan 2&4

The standard system fan 2 has just one fan cable; the redundant system fan 2&4 (dual fan, two fans are integrated internally) has two fan cables. The procedure for removing both system fans is identical except for connecting the fan cables.

Page 34: PRIMERGY TX200 S6 Server - Fujitsu Technology …manuals.ts.fujitsu.com/illustrated_spares/content/TX200_S6/pdf/og.pdf · The PRIMERGY TX200 S6 server is an Intel-based server for

34 Options Guide TX200 S6

Preparation

4.3.1 Removing system fan 2 (or 2&4)

Figure 9: Example: Removing system fan 2&4

Ê Disconnect the fan cable from the connector FAN2 (if there is a second fan cable, disconnect this from connector FAN4) on the system board (see the cabling plans in the Appendix).

Ê Press the two green locks of the air duct together (1).

Ê Press the green lock of the air duct in the direction of the arrow (2).

Ê Lift the air duct with the integrated system fan 2 (or 2&4) up and out (3).

Page 35: PRIMERGY TX200 S6 Server - Fujitsu Technology …manuals.ts.fujitsu.com/illustrated_spares/content/TX200_S6/pdf/og.pdf · The PRIMERGY TX200 S6 server is an Intel-based server for

TX200 S6 Options Guide 35

Preparation

4.3.2 Removing system fan 1 (or 1&3)

Ê Remove system fan 2 (or 2&4) (see page 34).

Figure 10: Example: Removing system fan 1&3

Ê Disconnect the fan cable from the connector FAN1 (if there is a second fan cable, disconnect this from connector FAN3) on the system board (see the cabling plans in the Appendix).

Ê Push the locking lever in the direction of the arrow (1).

Ê Pull system fan 1 (or 1&3) in the direction of the arrow (2) to disengage the four hooks.

Ê Take system fan 1 (or 1&3) out (3).

Page 36: PRIMERGY TX200 S6 Server - Fujitsu Technology …manuals.ts.fujitsu.com/illustrated_spares/content/TX200_S6/pdf/og.pdf · The PRIMERGY TX200 S6 server is an Intel-based server for

36 Options Guide TX200 S6

Preparation

Page 37: PRIMERGY TX200 S6 Server - Fujitsu Technology …manuals.ts.fujitsu.com/illustrated_spares/content/TX200_S6/pdf/og.pdf · The PRIMERGY TX200 S6 server is an Intel-based server for

TX200 S6 Options Guide 37

5 Main memoryV CAUTION!

● Before installing/removing memory to/from the server, turn off the server, all peripheral devices, and any other connected devices. Also unplug all power cords from the power outlet. Failure to do so can cause electric shock.

● A memory module consists of parts that are very vulnerable to damage by static electricity, and can easily be damaged by static electricity in the human body. Before handling memory modules, first touch a metal part of the server to discharge static electricity.

● Do not touch the circuitry on boards and soldered parts. Hold the metallic areas or the edge of the circuit boards.

● Do not install unauthorized third party memory modules. Doing so may cause electric shock, a fire, or failures.

● Wait for a sufficient period of time after server shutdown before installing or removing memory modules. Failure to do so may cause burns. When installing or removing memory modules, make sure to remove the screws at the specified points only. Failure to do so may cause injury. It may also cause failures.

● Touch only the specified part of the printed circuit board. Failure to do so may cause injury. It may also cause failures.

● Do not insert and remove memory modules repeatedly. Doing so may cause failures.

● If the memory module has not been correctly inserted, it may cause a fire. Insert the memory module with attention to its direction.

● If a memory module is installed and you pull the securing clips strongly outward, the memory module pops up. Doing so may cause a device failure.

● Follow the safety instructions in the chapter "Safety instructions" on page 19.

Page 38: PRIMERGY TX200 S6 Server - Fujitsu Technology …manuals.ts.fujitsu.com/illustrated_spares/content/TX200_S6/pdf/og.pdf · The PRIMERGY TX200 S6 server is an Intel-based server for

38 Options Guide TX200 S6

Main memory

5.1 Memory modules

The 12 slots (6 for each CPU) for main memory are designed for RDIMM (registered DIMM, capacities: 2, 4 and 8 GB) as well as for UDIMM (unbuffered DIMM, capacity: 2 GB) memory modules. The minimum population in the Independent Channel Mode is one DIMM. The maximum main memory is for installing UDIMM memory modules 24 GB, for installing RDIMM memory modules 96 GB. Mixing both types of memory modules is not supported and leads to an error message.

When using processors type X56xx/L56xx/E56xx LV-DIMMs (low voltage DIMMs) can be used.

ECC with memory scrubbing and with the Single Device Data Correction (SDDC) function is supported.

There are four modes of operation for the main memory:

– Independent Channel Mode– Mirrored Channel Mode– Performance Channel Mode– Spare Channel Mode

Depending on the mode of operation there are different population requirements.

I The types of memory modules and the modes of operation are described in the Technical Manual or in the configurator of the server.

I The current configurator can be found under:

http://ts.fujitsu.com/products/standard_server/tower/primergy_tx200s6.html(for the EMEA market)

http://primeserver.fujitsu.com/primergy/system.html (for the Japanese market)

Notes on equipping

– The minimum memory configuration is 1 DIMM per CPU in the Independent Channel Mode.

– Memory modules with different clock frequencies may be mixed. The system automatically adjusts itself to the lowest clock frequency.

– Single and dual ranked memory modules may be mixed.

Page 39: PRIMERGY TX200 S6 Server - Fujitsu Technology …manuals.ts.fujitsu.com/illustrated_spares/content/TX200_S6/pdf/og.pdf · The PRIMERGY TX200 S6 server is an Intel-based server for

TX200 S6 Options Guide 39

Main memory

– Memory modules of different capacities may be mixed on a bank by bank basis (2x2) in the Mirrored Channel Mode and in the Spare Channel Mode.

– The assignment of DIMM slots to the memory banks and channels is imprinted on the system board.

– Install memory modules within a channel in descending order of capacity: higher capacity in the black slot; lower capacity in the blue slot.

5.2 Expanding the main memory

Ê Open the server and remove system fan 2 (or 2&4) as described in the chapter "Preparation" on page 27.

Ê Press the securing clips on both sides of the memory slot concerned outward.

Figure 11: Expanding the memory module

Ê Carefully press the memory module into the slot (1) until the securing clips on both sides of it engage (2).

Ê Reinstall system fan 2 (or 2&4) as described in the section "Installing system fan 2 (or 2&4)" on page 102.

Ê Close the server, connect it to the power outlet, and switch it on as described in the chapter "Completion" on page 101.

Page 40: PRIMERGY TX200 S6 Server - Fujitsu Technology …manuals.ts.fujitsu.com/illustrated_spares/content/TX200_S6/pdf/og.pdf · The PRIMERGY TX200 S6 server is an Intel-based server for

40 Options Guide TX200 S6

Main memory

Page 41: PRIMERGY TX200 S6 Server - Fujitsu Technology …manuals.ts.fujitsu.com/illustrated_spares/content/TX200_S6/pdf/og.pdf · The PRIMERGY TX200 S6 server is an Intel-based server for

TX200 S6 Options Guide 41

6 ProcessorsV CAUTION!

● Before installing/removing processors to/from the server, turn off the server, all peripheral devices, and any other connected devices. Also unplug all power cords from the power outlet. Failure to do so can cause electric shock.

● Do not touch the circuitry on boards and soldered parts. Hold the metallic areas or the edge of the circuit boards.

● When adding a processor, be sure to add memory into "DIMM 1D" additionally. Refer to chapter "Main memory" on page 37 for the installation of the memory.

● When installing the processor, be careful not to bend the pins of the processor socket.

● Follow the safety instructions in the chapter "Safety instructions" on page 19.

V CAUTION!

Processors are modules which can react extremely sensitively to electrostatic discharges and which must therefore always be handled with care. After a processor has been removed from its protective sleeve or from its socket, place it with its smooth side down on a non-conducting, antistatic surface. Never slide a processor over a surface.

Page 42: PRIMERGY TX200 S6 Server - Fujitsu Technology …manuals.ts.fujitsu.com/illustrated_spares/content/TX200_S6/pdf/og.pdf · The PRIMERGY TX200 S6 server is an Intel-based server for

42 Options Guide TX200 S6

Processors

6.1 Installing a second processor

The system board can be upgraded with a second processor. The upgrade kit consists of a processor and a heat sink.

Figure 12: Configuration with two processors

V CAUTION!

Only processors of the same type may be used on the system board. That means the number of the internal processor cores as well as the primary clock and the FSB frequency have to be the same. For dual operation, use a suitable multiprocessor operating system.

Ê Open the server and remove system fan 2 (or 2&4) as described in the chapter "Preparation" on page 27.

Page 43: PRIMERGY TX200 S6 Server - Fujitsu Technology …manuals.ts.fujitsu.com/illustrated_spares/content/TX200_S6/pdf/og.pdf · The PRIMERGY TX200 S6 server is an Intel-based server for

TX200 S6 Options Guide 43

Processors

Figure 13: Opening the heat sink retaining clips

Ê Press the heat sink retaining clips downward and inward to release them (1).

Ê Swing the heat sink retaining clips up as far as they will go (2).

Page 44: PRIMERGY TX200 S6 Server - Fujitsu Technology …manuals.ts.fujitsu.com/illustrated_spares/content/TX200_S6/pdf/og.pdf · The PRIMERGY TX200 S6 server is an Intel-based server for

44 Options Guide TX200 S6

Processors

Figure 14: Opening the processor holder

Ê Release the spring clip by pressing it sideways and pull it upward as far as it will go (1).

Ê Open the processor holder (2).

Page 45: PRIMERGY TX200 S6 Server - Fujitsu Technology …manuals.ts.fujitsu.com/illustrated_spares/content/TX200_S6/pdf/og.pdf · The PRIMERGY TX200 S6 server is an Intel-based server for

TX200 S6 Options Guide 45

Processors

Figure 15: Removing the socket cover

Ê Hold the socket cover by the two grips between your thumb and index finger and lift it vertically upward.

Figure 16: Inserting the processor

Ê Hold the processor between your thumb and index finger and align it at the socket coding (see circle).

Page 46: PRIMERGY TX200 S6 Server - Fujitsu Technology …manuals.ts.fujitsu.com/illustrated_spares/content/TX200_S6/pdf/og.pdf · The PRIMERGY TX200 S6 server is an Intel-based server for

46 Options Guide TX200 S6

Processors

Ê Place the processor in the socket with great care.

V CAUTION!

Do not bend the spring contacts of the processor socket. Never touch the underside of the processor. Even light contaminants, such as oil from human skin, can destroy the processor or impair its functionality.

Figure 17: Locking the processor

Ê Close the processor holder (1).

Ê Lock the processor in the socket by returning the spring clip to its original position (2).

Page 47: PRIMERGY TX200 S6 Server - Fujitsu Technology …manuals.ts.fujitsu.com/illustrated_spares/content/TX200_S6/pdf/og.pdf · The PRIMERGY TX200 S6 server is an Intel-based server for

TX200 S6 Options Guide 47

Processors

Figure 18: Removing the protective cover

Ê Remove the protective cover on the underside of the heat sink.

V CAUTION!

Do not touch the thermal paste on the underside of the heat sink.

Figure 19: Mounting and locking the heat sink

Ê Mount the heat sink on the processor (1) so that the side with the visible copper heat pipes is pointing in the direction of the memory slots.

Page 48: PRIMERGY TX200 S6 Server - Fujitsu Technology …manuals.ts.fujitsu.com/illustrated_spares/content/TX200_S6/pdf/og.pdf · The PRIMERGY TX200 S6 server is an Intel-based server for

48 Options Guide TX200 S6

Processors

Ê Fold down the two heat sink retaining clips at the same time (2) and lock the heat sink by returning the heat sink retaining clips to their original position.

Figure 20: Heat sink installed

Ê Reinstall system fan 2 (or 2&4) as described in the section "Installing system fan 2 (or 2&4)" on page 102.

Ê Close the server, connect it to the power outlet, and switch it on as described in the chapter "Completion" on page 101.

6.2 Replacing the processor

V CAUTION!

Only processors of the same type may be used on the system board. That means the number of the internal processor cores as well as the primary clock and the FSB frequency have to be the same. For dual operation, use a suitable multiprocessor operating system.

Ê Open the server and remove system fan 2 (or 2&4) as described in the chapter "Preparation" on page 27.

Ê Press the heat sink retaining clips downward and inward to release them.

Ê Swing the heat sink retaining clips up as far as they will go.

Ê Loosen the heat sink by turning it back and forth and then lift it out.

Page 49: PRIMERGY TX200 S6 Server - Fujitsu Technology …manuals.ts.fujitsu.com/illustrated_spares/content/TX200_S6/pdf/og.pdf · The PRIMERGY TX200 S6 server is an Intel-based server for

TX200 S6 Options Guide 49

Processors

Ê Remove the residual thermal paste from the underside of the heat sink.

Ê Clean the underside of the heat sink using a lint-free cloth.

Ê Release the spring clip by pressing it sideways and pull it upward as far as it will go.

Ê Open the processor holder.

Ê Carefully lift the installed processor out of the socket.

Ê Hold the new processor between your thumb and index finger and align it at the socket coding.

Ê Place the new processor in the socket with great care.

V CAUTION!

Do not bend the spring contacts of the processor socket. Never touch the underside of the processor. Even light contaminants, such as oil from human skin, can destroy the processor or impair its functionality.

Ê Close the processor holder.

Ê Lock the processor in the socket by returning the spring clip to its original position.

Ê Apply a small amount of thermal paste to the upper side of the new processor.

Ê Ensure a thin and even distribution of the thermal paste.

Ê Mount the heat sink on the processor so that the side with the visible copper heat pipes is pointing in the direction of the memory slots.

Ê Fold down the two heat sink retaining clips at the same time and lock the heat sink by returning the heat sink retaining clips to their original position.

Ê Reinstall system fan 2 (or 2&4) as described in the section "Installing system fan 2 (or 2&4)" on page 102.

Ê Close the server, connect it to the power outlet, and switch it on as described in the chapter "Completion" on page 101.

Page 50: PRIMERGY TX200 S6 Server - Fujitsu Technology …manuals.ts.fujitsu.com/illustrated_spares/content/TX200_S6/pdf/og.pdf · The PRIMERGY TX200 S6 server is an Intel-based server for

50 Options Guide TX200 S6

Processors

6.3 Replacing the heat sink

Ê Open the server and remove system fan 2 (or 2&4) as described in the chapter "Preparation" on page 27.

Ê Press the heat sink retaining clips downward and inward to release them.

Ê Swing the heat sink retaining clips up as far as they will go.

Ê Loosen the heat sink by turning it back and forth and then lift it out.

Ê Clean the upper side of the processor using a lint-free cloth.

Ê Remove the protective cover from the new heat sink.

Ê Mount the heat sink on the processor so that the side with the visible copper heat pipes is pointing in the direction of the memory slots.

Ê Fold down the two heat sink retaining clips at the same time and lock the heat sink by returning the heat sink retaining clips to their original position.

Ê Reinstall system fan 2 (or 2&4) as described in the section "Installing system fan 2 (or 2&4)" on page 102.

Ê Close the server, connect it to the power outlet, and switch it on as described in the chapter "Completion" on page 101.

Page 51: PRIMERGY TX200 S6 Server - Fujitsu Technology …manuals.ts.fujitsu.com/illustrated_spares/content/TX200_S6/pdf/og.pdf · The PRIMERGY TX200 S6 server is an Intel-based server for

TX200 S6 Options Guide 51

7 Accessible drives and LSD/LSPV CAUTION!

● Before installing/removing an accessible drive to/from the server, turn off the server, all peripheral devices, and any other connected devices. Also unplug all power cords from the power outlet. Failure to do so can cause electric shock.

● When installing an accessible drive, hold it by the side. Applying force to the top may cause failures.

● Do not touch the circuitry on boards and soldered parts. Hold the metallic areas or the edge of the circuit boards.

● The circuit boards and soldered parts of internal options are exposed and can be damaged by static electricity. Before handling them, first touch a metal part on the server to discharge static electricity from your body.

● Before installing an internal accessible drive, see the manual for the accessible drive.

● When forcing an accessible drive into a server, be careful so as not to pinch the cable etc. connected to an accessible drive.

● Follow the safety instructions in the chapter "Safety instructions" on page 19.

Page 52: PRIMERGY TX200 S6 Server - Fujitsu Technology …manuals.ts.fujitsu.com/illustrated_spares/content/TX200_S6/pdf/og.pdf · The PRIMERGY TX200 S6 server is an Intel-based server for

52 Options Guide TX200 S6

Accessible drives and LSD/LSP

7.1 Equipping of the bays

Three 5.25-inch bays are available for accessible drives. You can install DVD drives, magnetic tape drives, a multibay (slimline DVD and ServerView Local Service Display/ServerView Local Service Panel), or an HDD extension box in these bays.

Figure 21: Bays for accessible drives

Bay 1: 5.25“ x 1.6“

Bay 2: 5.25“ x 1.6“

Bay 3: 5.25“ x 1.6“

Multibay 3.5“ HDD extension

box

Slimline DVD

LSP/LSD

free

free

free

2.5“ HDD extension

box + multibay

Slimline DVD

LSP/LSD

Slimline DVD

LSP/LSD

3.5“ HDD

3.5“ HDD

8 x

2.5“ HDDs

Page 53: PRIMERGY TX200 S6 Server - Fujitsu Technology …manuals.ts.fujitsu.com/illustrated_spares/content/TX200_S6/pdf/og.pdf · The PRIMERGY TX200 S6 server is an Intel-based server for

TX200 S6 Options Guide 53

Accessible drives and LSD/LSP

Recommended equipping of the bays:

Sequence Accessible drives Bay Max. number

Bays occupied

1. Multibay with– SATA DVD-ROM

slimline– LSD or LSP

Bay 1 1 1 x 1.6" x 5.25"

2. HDD extension box 3.5"– SATA DVD-ROM

slimline– LSD or LSP– two 3.5" HDD bays

Bay 2 + 3 1 1 x 3.2" x 5.25"

3. DVD drive– DVD-ROM SATA– DVD-RW SATA

Bay 1

If bay 1 is occupied, bay 2

1 1 x 1.6" x 5.25"

4. HDD extension box 2.5"– eight 2.5" HDD bays

Bay 2 + 3 1 1 x 3.2" x 5.25"

5. Tape drive LTOx Bay 2

If bay 2 is occupied, bay 3

If HDD extension box 2.5 " or 3.5" mounted, bay 1

1 1 x 1.6" x 5.25"

6. Tape drive DAT Bay 2

If bay 2 is occupied, bay 3

If HDD extension box 2.5 " or 3.5" mounted, bay 1

1 1 x 1.6" x 5.25"

7. Tape drive RDX Bay 2

If bay 2 is occupied, bay 3

If HDD extension box 2.5 " or 3.5" mounted, bay 1

2 1 x 1.6" x 5.25"

Page 54: PRIMERGY TX200 S6 Server - Fujitsu Technology …manuals.ts.fujitsu.com/illustrated_spares/content/TX200_S6/pdf/og.pdf · The PRIMERGY TX200 S6 server is an Intel-based server for

54 Options Guide TX200 S6

Accessible drives and LSD/LSP

7.2 Installing an accessible 5.25-inch drive

Magnetic tape drives and DVD drives are available as accessible 5.25-inch drives. These drives can be installed in the free 5.25-inch bays.

Ê Open the server as described in the chapter "Preparation" on page 27.

Ê Remove the front cover or rack front cover as described in the section "Removing the front cover" on page 29 or in the section "Removing the rack front cover" on page 32.

I New 5.25-inch drives are supplied without EasyClick rails. Before installing a new 5.25-inch drive you must therefore remove the EasyClick rails from the dummy cover and mount the EasyClick rails on the new 5.25-inch drive.

I If you install a magnetic tape drive with double height (3.2-inch), two dummy covers of the free 5.25-inch bays must be removed.

Figure 22: Removing the dummy cover

Ê Press the metal tongues on the sides of the EasyClick rails inward (1) until the locking mechanism disengages.

Ê Pull the dummy cover out of the bay frontward (2).

Page 55: PRIMERGY TX200 S6 Server - Fujitsu Technology …manuals.ts.fujitsu.com/illustrated_spares/content/TX200_S6/pdf/og.pdf · The PRIMERGY TX200 S6 server is an Intel-based server for

TX200 S6 Options Guide 55

Accessible drives and LSD/LSP

Figure 23: Removing EasyClick rails

Ê Detach the EasyClick rails from the dummy cover by removing the four screws on each side.

I Note that there are two M3 x 4.5mm screws with M3 thread (yellow ellipse) and two 6-32 x 4.8mm screws with UNC thread (blue ellipse) on each side.

V CAUTION!

Keep the dummy cover for future use. If you remove the accessible drive again and do not replace it with a new one, the dummy cover must be reinstalled to comply with EMC regulations and to satisfy cooling requirements and fire protection measures.

Figure 24: Attaching the EasyClick rails - example: DVD drive

Ê Screw the EasyClick rails onto either side of the new 5.25-inch drive using two M3x4.5mm screws.

Use the first hole in each lower row of holes as shown in the figure.

Page 56: PRIMERGY TX200 S6 Server - Fujitsu Technology …manuals.ts.fujitsu.com/illustrated_spares/content/TX200_S6/pdf/og.pdf · The PRIMERGY TX200 S6 server is an Intel-based server for

56 Options Guide TX200 S6

Accessible drives and LSD/LSP

I Keep the remaining screws for future use. The different drives are fastened using different screws.

Please use the screws which are provided with the packaging contents of the tape drive.

Figure 25: Inserting the accessible drive - example DVD drive

Ê Push the 5.25-inch drive fully into the bay until the EasyClick rails lock in place.

Page 57: PRIMERGY TX200 S6 Server - Fujitsu Technology …manuals.ts.fujitsu.com/illustrated_spares/content/TX200_S6/pdf/og.pdf · The PRIMERGY TX200 S6 server is an Intel-based server for

TX200 S6 Options Guide 57

Accessible drives and LSD/LSP

Figure 26: Routing the accessible drive - DVD example

Ê Connect the data cable (1) to the accessible drive (see the cabling plans in the Appendix).

I The DVD SATA cable (T26139-Y3928-V205) is already pre-mounted and connected to the SATA5 connector of the system board.

Ê Connect the power cable (2) to the accessible drive (see the cabling plans in the Appendix).

Ê If necessary, connect the data cable to the system board or to a RAID controller (see the cabling plans in the Appendix).

Ê Attach the front cover or rack front cover as described in the section "Attaching the front cover" on page 103 or in the section "Attaching the rack front cover" on page 105.

Ê Close the server, connect it to the power outlet, and switch it on as described in the chapter "Completion" on page 101.

Page 58: PRIMERGY TX200 S6 Server - Fujitsu Technology …manuals.ts.fujitsu.com/illustrated_spares/content/TX200_S6/pdf/og.pdf · The PRIMERGY TX200 S6 server is an Intel-based server for

58 Options Guide TX200 S6

Accessible drives and LSD/LSP

7.3 Installing the multibay

The multibay can be equipped with a slimline DVD and a ServerView Local Service Panel (LSP) or a ServerView Local Service Display (LSD).

Ê Open the server as described in the chapter "Preparation" on page 27.

Ê Remove the dummy cover from one 5.25-inch bay for accessible drives (see figure 22 on page 54).

Ê Detach the EasyClick rails from the dummy cover by removing the four screws on each side (see figure 23 on page 55).

V CAUTION!

Keep the dummy cover for future use. If you remove the multibay again and do not replace it with a new drive, the dummy cover must be reinstalled to comply with EMC regulations and to satisfy cooling requirements and fire safety protection measures.

Installing LSP or LSD in the multibay

Figure 27: ServerView Local Service Display (LSD) and ServerView Local Service Panel (LSP)

Page 59: PRIMERGY TX200 S6 Server - Fujitsu Technology …manuals.ts.fujitsu.com/illustrated_spares/content/TX200_S6/pdf/og.pdf · The PRIMERGY TX200 S6 server is an Intel-based server for

TX200 S6 Options Guide 59

Accessible drives and LSD/LSP

Figure 28: Sliding the LSP in the 3.5-inch frame

Ê Slide the LSP/LSD in the 3.5-inch frame from the front until it engages (see the snap-in hook in the circle).

Figure 29: Sliding the 3.5-inch frame with the LSP in the multibay

Ê Slide the 3.5-inch frame with the LSP/LSD in the multibay from the rear.

Page 60: PRIMERGY TX200 S6 Server - Fujitsu Technology …manuals.ts.fujitsu.com/illustrated_spares/content/TX200_S6/pdf/og.pdf · The PRIMERGY TX200 S6 server is an Intel-based server for

60 Options Guide TX200 S6

Accessible drives and LSD/LSP

Figure 30: Fastening the 3.5-inch frame with the LSP in the multibay

Ê Fasten the 3.5-inch frame in the multibay using two M3 x 6 mm screws on either side.

Installing the slimline DVD

Figure 31: Inserting the slimline DVD in the frame

Ê Insert the slimline DVD in the frame.

Ensure that the four pins on the frame engage with the screw holes on the DVD and fix them in this position.

Page 61: PRIMERGY TX200 S6 Server - Fujitsu Technology …manuals.ts.fujitsu.com/illustrated_spares/content/TX200_S6/pdf/og.pdf · The PRIMERGY TX200 S6 server is an Intel-based server for

TX200 S6 Options Guide 61

Accessible drives and LSD/LSP

Figure 32: Sliding the slimline DVD in the multibay

Ê Slide the slimline DVD in the multibay from the front until it engages (see the snap-in hook in the circle).

Figure 33: Attaching EasyClick rails to the multibay

Ê Screw the EasyClick rails onto either side using two M3 x 4.5 mm screws.

Page 62: PRIMERGY TX200 S6 Server - Fujitsu Technology …manuals.ts.fujitsu.com/illustrated_spares/content/TX200_S6/pdf/og.pdf · The PRIMERGY TX200 S6 server is an Intel-based server for

62 Options Guide TX200 S6

Accessible drives and LSD/LSP

Figure 34: Routing the slimline DVD

I The DVD SATA cable (T26139-Y3928-V205) is already pre-mounted and connected to the SATA5 connector of the system board.

Ê Disconnect the DVD SATA cable from the SATA5 connector of the system board in order to move the cable.

Ê Pull the DVD SATA cable out of the bay towards the front.

Ê Pull the power cable (P19 plug) out of the bay towards the front.

Ê Connect the power cable to the slimline DVD.

Ê Connect the DVD SATA cable to the slimline DVD.

Page 63: PRIMERGY TX200 S6 Server - Fujitsu Technology …manuals.ts.fujitsu.com/illustrated_spares/content/TX200_S6/pdf/og.pdf · The PRIMERGY TX200 S6 server is an Intel-based server for

TX200 S6 Options Guide 63

Accessible drives and LSD/LSP

Figure 35: Installing the multibay

Ê Push the multibay fully into the top bay until the EasyClick rails lock in place. Make sure that the cables do not become trapped.

Figure 36: Cabling the LSP/LSD

Ê Connect the small plug of the front panel cable to the LSP/LSD (see the cabling plans in the Appendix).

Ê Reconnect the DVD SATA cable plug to the SATA5 connector of the system board.

Ê Close the server, connect it to the power outlet, and switch it on as described in the chapter "Completion" on page 101.

Page 64: PRIMERGY TX200 S6 Server - Fujitsu Technology …manuals.ts.fujitsu.com/illustrated_spares/content/TX200_S6/pdf/og.pdf · The PRIMERGY TX200 S6 server is an Intel-based server for

64 Options Guide TX200 S6

Accessible drives and LSD/LSP

7.4 Installing the hard disks extension box

Two 5.25-inch bays for accessible drives can be used to install an HDD extension box. Two variants of the HDD extension box are available:

– Variant 1: one bay for a LSP/LSD, one bay for a slimline DVD drive and two bays for 3.5-inch SAS/SATA HDD modules

I If the lower hard disk drive cage is connected to the onboard SATA controller, an additional SAS/SATA RAID controller needs to be installed in order to connect the HDD extension box.

If the lower hard disk drive cage is connected to a SAS/SATA RAID controller, the HDD extension box can be connected to the second channel of the SAS/SATA RAID controller.

V CAUTION!

Hybrid configurations of SAS and SATA HDD modules in the HDD extension box are not supported.

– Variant 2: eight bays for 2.5-inch SAS/SATA HDD modules

I A further SAS/SATA RAID controller needs to be installed to connect the HDD extension box.

V CAUTION!

Hybrid configurations of SAS and SATA HDD modules are not supported.

Ê Open the server as described in the chapter "Preparation" on page 27.

Ê Remove the dummy covers from two 5.25-inch bays for accessible drives (see figure 22 on page 54).

Ê Detach the EasyClick rails from a dummy cover by removing the four screws on each side (see figure 23 on page 55).

V CAUTION!

Keep the dummy covers for future use. If you remove the HDD extension box again and do not replace it with new drives, the dummy covers must be reinstalled to comply with EMC regulations and to satisfy cooling requirements and fire protection measures.

Page 65: PRIMERGY TX200 S6 Server - Fujitsu Technology …manuals.ts.fujitsu.com/illustrated_spares/content/TX200_S6/pdf/og.pdf · The PRIMERGY TX200 S6 server is an Intel-based server for

TX200 S6 Options Guide 65

Accessible drives and LSD/LSP

3.5-inch HDD extension box

Figure 37: Attaching EasyClick rails to the 3.5-inch HDD extension box

Ê Screw the EasyClick rails onto either side using two M3 x 4.5 mm screws.

Figure 38: Installing the 3.5-inch HDD extension box

Ê Push the 3.5-inch HDD extension box fully into the two lower bays until the EasyClick rails lock in place.

Page 66: PRIMERGY TX200 S6 Server - Fujitsu Technology …manuals.ts.fujitsu.com/illustrated_spares/content/TX200_S6/pdf/og.pdf · The PRIMERGY TX200 S6 server is an Intel-based server for

66 Options Guide TX200 S6

Accessible drives and LSD/LSP

If you want to install a slimline DVD:

Figure 39: Installing a slimline DVD in the 3.5-inch HDD extension box

I The DVD SATA cable (T26139-Y3928-V205) is already pre-mounted and connected to the SATA5 connector of the system board.

Ê Disconnect the DVD SATA cable from the SATA5 connector of the system board in order to move the cable.

Ê Pull the DVD SATA cable out of the upper bay of the 3.5-inch HDD extension box towards the front.

Ê Pull the power cable (P19 plug) cable out of the upper bay of the 3.5-inch HDD extension box towards the front.

Ê Connect the power cable to the slimline DVD.

Ê Connect the DVD SATA cable to the slimline DVD.

Ê Slide the slimline DVD into the 3.5-inch HDD extension box from the front until it engages. Make sure that the cables do not become trapped.

Ê Reconnect the DVD SATA cable plug to the SATA5 connector of the system board.

Page 67: PRIMERGY TX200 S6 Server - Fujitsu Technology …manuals.ts.fujitsu.com/illustrated_spares/content/TX200_S6/pdf/og.pdf · The PRIMERGY TX200 S6 server is an Intel-based server for

TX200 S6 Options Guide 67

Accessible drives and LSD/LSP

If you want to install a LSP/LSD:

Figure 40: Installing a LSP/LSD in the 3.5-inch HDD extension box

Ê Slide the LSP/LSP in the top bay of the 3.5-inch HDD extension box.

Page 68: PRIMERGY TX200 S6 Server - Fujitsu Technology …manuals.ts.fujitsu.com/illustrated_spares/content/TX200_S6/pdf/og.pdf · The PRIMERGY TX200 S6 server is an Intel-based server for

68 Options Guide TX200 S6

Accessible drives and LSD/LSP

Figure 41: Example: Connecting the cables

Ê Connect the small plug of the front panel cable (1) to the LSP/LSD (see the cabling plans in the Appendix).

Ê Connect the power cable (2) plug P16 to the 3.5-inch HDD extension box (see the cabling plans in the Appendix).

Ê Connect a SAS/SATA cable (3) to the 3.5-inch HDD extension box and the SAS/SATA RAID controller (see the cabling plans in the Appendix).

Page 69: PRIMERGY TX200 S6 Server - Fujitsu Technology …manuals.ts.fujitsu.com/illustrated_spares/content/TX200_S6/pdf/og.pdf · The PRIMERGY TX200 S6 server is an Intel-based server for

TX200 S6 Options Guide 69

Accessible drives and LSD/LSP

Figure 42: Installing 3.5-inch HDD modules

Ê Install up to two 3.5-inch HDD modules (description see the operating manual).

Ê Close the server, connect it to the power outlet, and switch it on as described in the chapter "Completion" on page 101.

Page 70: PRIMERGY TX200 S6 Server - Fujitsu Technology …manuals.ts.fujitsu.com/illustrated_spares/content/TX200_S6/pdf/og.pdf · The PRIMERGY TX200 S6 server is an Intel-based server for

70 Options Guide TX200 S6

Accessible drives and LSD/LSP

2.5-inch HDD extension box

Figure 43: Attaching EasyClick rails to the 2.5-inch HDD extension box

Ê Screw the EasyClick rails onto either side using two M3 x 4.5 mm screws.

Figure 44: Installing the 2.5-inch HDD extension box

Ê Push the 2.5-inch HDD extension box fully into the two lower bays until the EasyClick rails lock in place.

Page 71: PRIMERGY TX200 S6 Server - Fujitsu Technology …manuals.ts.fujitsu.com/illustrated_spares/content/TX200_S6/pdf/og.pdf · The PRIMERGY TX200 S6 server is an Intel-based server for

TX200 S6 Options Guide 71

Accessible drives and LSD/LSP

Figure 45: Example: Connecting the power cable

Ê Connect the power cable plugs P13 and P16 to the 2.5-inch HDD extension box (see the cabling plans in the Appendix).

Figure 46: Example: Connecting the SAS cable

Ê Connect the two SAS cables to the 2.5-inch HDD extension box and the SAS/SATA RAID controller (see the cabling plans in the Appendix).

Page 72: PRIMERGY TX200 S6 Server - Fujitsu Technology …manuals.ts.fujitsu.com/illustrated_spares/content/TX200_S6/pdf/og.pdf · The PRIMERGY TX200 S6 server is an Intel-based server for

72 Options Guide TX200 S6

Accessible drives and LSD/LSP

Figure 47: Installing 2.5-inch HDD modules

Ê You can install up to eight 2.5-inch HDD modules (description see the operating manual).

Ê Close the server, connect it to the power outlet, and switch it on as described in the chapter "Completion" on page 101.

Page 73: PRIMERGY TX200 S6 Server - Fujitsu Technology …manuals.ts.fujitsu.com/illustrated_spares/content/TX200_S6/pdf/og.pdf · The PRIMERGY TX200 S6 server is an Intel-based server for

TX200 S6 Options Guide 73

8 Expansion cards and BBUV CAUTION!

● Before installing/removing expansion cards to/from the server, turn off the server, all peripheral devices, and any other connected devices. Also unplug all power cables from the power outlet. Failure to do so can cause electric shock.

● The circuit boards and soldered parts of internal options are exposed and can be damaged by static electricity. Before handling them, first touch a metal part on the server to discharge static electricity from your body.

● Do not touch the circuitry on boards and soldered parts. Hold the metallic areas or the edge of the circuit boards.

● Follow the safety instructions in the chapter "Safety instructions" on page 19.

8.1 Installing expansion cards

The system board offers six PCI slots:– 5 x PCIe slots, all mechanical x8:

– 2x PCIe x8 slots (Gen2), one slot is open on the right side to allow a x16 graphics card to be inserted

– 2x PCIe x4 slots (Gen2)– 1x PCIe x4 slot (Gen1)

– 1 x PCI slot (32 bit / 33 MHz)

I Boot controller:Slot 1 and slot 5 are configured for the boot controller by default. If a boot controller is to be operated on another slot, this needs to be configured in the BIOS Setup (Advanced/PCI Configuration/PCI SLOTS Configuration/Option ROM Scan: Enabled, see the BIOS Setup manual). The “Option ROM Scan“ setting specifies whether the adapter BIOS is started by the system BIOS in the respective PCI slot.

I For the installing order see the configurator of the server: https://sp.ts.fujitsu.com/dmsp/docs/cnfgtx200s6.pdf(for the EMEA market)http://primeserver.fujitsu.com/primergy/system.html (for the Japanese market)

Page 74: PRIMERGY TX200 S6 Server - Fujitsu Technology …manuals.ts.fujitsu.com/illustrated_spares/content/TX200_S6/pdf/og.pdf · The PRIMERGY TX200 S6 server is an Intel-based server for

74 Options Guide TX200 S6

Expansion cards and BBU

Ê Open the server and remove system fan 2 (or 2&4) as described in the chapter "Preparation" on page 27.

Figure 48: Removing the slot cover

Ê Open the slot locking bar (1).

Ê Remove the slot locking bar (2).

Ê Remove the PCI slot cover (3).

V CAUTION!

Keep the slot cover for further use. If the expansion card is removed again and not replaced with a new one, the slot cover has to be reinstalled to comply with applicable EMC regulations and satisfy cooling requirements and fire protection measures.

Ê Unpack the new expansion card, and make the desired settings. You should read the accompanying documentation supplied with the expansion card beforehand.

Page 75: PRIMERGY TX200 S6 Server - Fujitsu Technology …manuals.ts.fujitsu.com/illustrated_spares/content/TX200_S6/pdf/og.pdf · The PRIMERGY TX200 S6 server is an Intel-based server for

TX200 S6 Options Guide 75

Expansion cards and BBU

Figure 49: Installing the expansion card

Ê Carefully press the new expansion card into the relevant PCI slot on the system board (1) until it clicks into place.

Ê Fit the clip onto the slot cover so that the pin fits into the hole.

Ê Push the clip under the metal nose (2) until it clicks into place.

Ê Swing the lever (3) downwards into its locking position.

Ê If required, connect the cables to the expansion card and other components.

Page 76: PRIMERGY TX200 S6 Server - Fujitsu Technology …manuals.ts.fujitsu.com/illustrated_spares/content/TX200_S6/pdf/og.pdf · The PRIMERGY TX200 S6 server is an Intel-based server for

76 Options Guide TX200 S6

Expansion cards and BBU

V CAUTION!

If a long expansion card was installed, the plastic part of system fan 2 (or 2&4), which belongs to the related slot, must be broken off before system fan 2 (or 2&4) is installed.

Figure 50: Example: System fan 2 - Breaking off plastic part

Ê Reinstall system fan 2 (or 2&4) as described in the section "Installing system fan 2 (or 2&4)" on page 102.

Ê Close the server, connect it to the power outlet, and switch it on as described in the chapter "Completion" on page 101.

Page 77: PRIMERGY TX200 S6 Server - Fujitsu Technology …manuals.ts.fujitsu.com/illustrated_spares/content/TX200_S6/pdf/og.pdf · The PRIMERGY TX200 S6 server is an Intel-based server for

TX200 S6 Options Guide 77

Expansion cards and BBU

8.2 Installing a BBU

V CAUTION!

● Do not connect the cable using excessive force, the connector is weak.

● Follow the safety instructions in the chapter "Safety instructions" on page 19.

You can install up to two Battery Backup Units (BBU).

Ê Open the server and remove system fan 2 (or 2&4) as described in the chapter "Preparation" on page 27.

Figure 51: Removing the BBU carrier plate

Ê Loosen the knurled screw and remove the BBU carrier plate in the direction of the arrow.

Page 78: PRIMERGY TX200 S6 Server - Fujitsu Technology …manuals.ts.fujitsu.com/illustrated_spares/content/TX200_S6/pdf/og.pdf · The PRIMERGY TX200 S6 server is an Intel-based server for

78 Options Guide TX200 S6

Expansion cards and BBU

Figure 52: Connecting the cable to the BBU

Ê Connect the BBU cable to the BBU.

V CAUTION!

Make sure that the connector side with the blank pins is facing the board. Otherwise you risk short-circuits.

Figure 53: Fastening the BBU onto the carrier plate

Ê Fasten the BBU onto the BBU carrier plate using the three screws supplied (1).

Page 79: PRIMERGY TX200 S6 Server - Fujitsu Technology …manuals.ts.fujitsu.com/illustrated_spares/content/TX200_S6/pdf/og.pdf · The PRIMERGY TX200 S6 server is an Intel-based server for

TX200 S6 Options Guide 79

Expansion cards and BBU

Figure 54: Fastening the second BBU onto the carrier plate

Ê In case of a configuration with two BBUs:

Ê Connect the BBU cable to the second BBU.

Ê Fasten the second BBU onto the BBU carrier plate using the three screws supplied.

Figure 55: Installing the BBU carrier plate

Ê Push the BBU carrier plate into the housing bracket (A).

Ê Fasten the BBU carrier plate using the knurled screw.

BBU 1BBU 2

A

Page 80: PRIMERGY TX200 S6 Server - Fujitsu Technology …manuals.ts.fujitsu.com/illustrated_spares/content/TX200_S6/pdf/og.pdf · The PRIMERGY TX200 S6 server is an Intel-based server for

80 Options Guide TX200 S6

Expansion cards and BBU

Figure 56: Example: Connecting the BBU cable to the controller

Ê Install a controller as described in the section "Installing expansion cards" on page 73.

V CAUTION!

Make sure that the connector side with the blank pins is facing the board. Otherwise you risk short-circuits.

Ê Route the BBU cable in the cable clamps and connect it to the controller.

Ê In case of a configuration with two BBUs:

Ê Install a further controller.

Ê Route the BBU cable in the cable clamps and connect it to the controller.

Ê Reinstall system fan 2 (or 2&4) as described in the section "Installing system fan 2 (or 2&4)" on page 102.

Ê Close the server, connect it to the power outlet, and switch it on as described in the chapter "Completion" on page 101.

Page 81: PRIMERGY TX200 S6 Server - Fujitsu Technology …manuals.ts.fujitsu.com/illustrated_spares/content/TX200_S6/pdf/og.pdf · The PRIMERGY TX200 S6 server is an Intel-based server for

TX200 S6 Options Guide 81

9 Further optionsV CAUTION!

Follow the safety instructions in the chapter "Safety instructions" on page 19.

9.1 TPM

The server can be equipped with a TPM (Trusted Platform Module).

Figure 57: TPM installation kit

Ê Open the server and remove system fan 2 (or 2&4) as described in the chapter "Preparation" on page 27.

1 TPM (Trusted Platform Module) 3 Special screw for TPM

2 TPM spacer

I The black TPM spacer is not used in this server.

4 TPM screwdriver insert bit forTPM special screw

� � � �

Page 82: PRIMERGY TX200 S6 Server - Fujitsu Technology …manuals.ts.fujitsu.com/illustrated_spares/content/TX200_S6/pdf/og.pdf · The PRIMERGY TX200 S6 server is an Intel-based server for

82 Options Guide TX200 S6

Further options

Figure 58: Inserting the TPM spacer on the system board

Ê Insert the TPM spacer into the hole on the system board.

Figure 59: Fastening the TPM

Ê Insert the TPM on the system board (1).

Ê Fasten the TPM with the special screw for the TPM (2).

Please use the TPM screwdriver insert bit to tighten the special screw.

I Do not fasten the screw too tightly (torque value of 0.6 Nm).

Page 83: PRIMERGY TX200 S6 Server - Fujitsu Technology …manuals.ts.fujitsu.com/illustrated_spares/content/TX200_S6/pdf/og.pdf · The PRIMERGY TX200 S6 server is an Intel-based server for

TX200 S6 Options Guide 83

Further options

Ê Reinstall system fan 2 (or 2&4) as described in the section "Installing system fan 2 (or 2&4)" on page 102.

Ê Close the server, connect it to the power outlet, and switch it on as described in the chapter "Completion" on page 101.

I You can find information on configuring the TPM in the "D2799 BIOS Setup Utility for TX200 S6" manual.

9.2 USB Flash Module (UFM)

The server can be equipped with a USB Flash Module (UFM).

Figure 60: UFM installation kit

Ê Open the server as described in the chapter "Preparation" on page 27.

1 USB Flash Module (UFM) 3 UFM spacer

2 UFM nylon screw

Page 84: PRIMERGY TX200 S6 Server - Fujitsu Technology …manuals.ts.fujitsu.com/illustrated_spares/content/TX200_S6/pdf/og.pdf · The PRIMERGY TX200 S6 server is an Intel-based server for

84 Options Guide TX200 S6

Further options

Figure 61: UFM - Position on the system board

Figure 62: Connecting the UFM to the system board

Ê Connect the USB Flash Module to the system board. The spacer must click into the hole on the system board.

Ê Close the server, connect it to the power outlet, and switch it on as described in the chapter "Completion" on page 101.

Page 85: PRIMERGY TX200 S6 Server - Fujitsu Technology …manuals.ts.fujitsu.com/illustrated_spares/content/TX200_S6/pdf/og.pdf · The PRIMERGY TX200 S6 server is an Intel-based server for

TX200 S6 Options Guide 85

Further options

9.3 Second serial connector

Ê Open the server and remove system fan 2 (or 2&4) as described in the chapter "Preparation" on page 27.

Figure 63: Second serial connector installation kit

Figure 64: Replacing the slot cover

Ê Remove the two screws on the short slot cover.

Ê Insert the serial connector in the long slot cover.

Ê Fasten the long slot cover with the two screws.

1 Long slot cover 2 Second serial connector with short slot cover

Page 86: PRIMERGY TX200 S6 Server - Fujitsu Technology …manuals.ts.fujitsu.com/illustrated_spares/content/TX200_S6/pdf/og.pdf · The PRIMERGY TX200 S6 server is an Intel-based server for

86 Options Guide TX200 S6

Further options

Figure 65: Installing the serial connector

Ê Insert the long slot cover with the serial connector in slot 7 (1) as described in the section "Installing expansion cards" on page 73.

Ê Route the cable in the bracket on the right (2) as shown in the photo.

Ê Connect the free end of the cable to the COM2 connector on the system board (3).

Ê Reinstall system fan 2 (or 2&4) as described in the section "Installing system fan 2 (or 2&4)" on page 102.

Ê Close the server, connect it to the power outlet, and switch it on as described in the chapter "Completion" on page 101.

Page 87: PRIMERGY TX200 S6 Server - Fujitsu Technology …manuals.ts.fujitsu.com/illustrated_spares/content/TX200_S6/pdf/og.pdf · The PRIMERGY TX200 S6 server is an Intel-based server for

TX200 S6 Options Guide 87

10 Conversion to hot-plug PS and redundant system fans

V CAUTION!

Follow the safety instructions in the chapter "Safety instructions" on page 19.

Ê Open the server as described in the chapter "Preparation" on page 27.

V CAUTION!

System fans 1 and 2 are replaced by the redundant system fans 1&3 and 2&4.

Ê Remove system fan 2 as described in the section "Removing system fan 2 (or 2&4)" on page 34.

Ê Remove system fan 1 as described in the section "Removing system fan 1 (or 1&3)" on page 35.

Ê Disconnect all power cables from the system board and the drives (see the cabling plans in the Appendix).

Ê Remove all power cables from the cable clamps.

Page 88: PRIMERGY TX200 S6 Server - Fujitsu Technology …manuals.ts.fujitsu.com/illustrated_spares/content/TX200_S6/pdf/og.pdf · The PRIMERGY TX200 S6 server is an Intel-based server for

88 Options Guide TX200 S6

Conversion to hot-plug PS and redundant system fans

Figure 66: Removing the standard power supply fixing plate

Ê Loosen the screw (1).

Ê Slide the standard power supply fixing plate in the direction of the arrow (2) and take it out.

Page 89: PRIMERGY TX200 S6 Server - Fujitsu Technology …manuals.ts.fujitsu.com/illustrated_spares/content/TX200_S6/pdf/og.pdf · The PRIMERGY TX200 S6 server is an Intel-based server for

TX200 S6 Options Guide 89

Conversion to hot-plug PS and redundant system fans

Figure 67: Power supply - Removing the screw

Ê Remove the four screws.

Figure 68: Removing the PSU

Ê Pull the power supply unit inward and take it out of the server.

Page 90: PRIMERGY TX200 S6 Server - Fujitsu Technology …manuals.ts.fujitsu.com/illustrated_spares/content/TX200_S6/pdf/og.pdf · The PRIMERGY TX200 S6 server is an Intel-based server for

90 Options Guide TX200 S6

Conversion to hot-plug PS and redundant system fans

Figure 69: Adapter metal cover - Removing the screws

Ê Remove the five screws.

Figure 70: Removing the adapter metal cover

Ê Pull the adapter metal cover inward and take it out of the server.

Page 91: PRIMERGY TX200 S6 Server - Fujitsu Technology …manuals.ts.fujitsu.com/illustrated_spares/content/TX200_S6/pdf/og.pdf · The PRIMERGY TX200 S6 server is an Intel-based server for

TX200 S6 Options Guide 91

Conversion to hot-plug PS and redundant system fans

Figure 71: Installing the Power backplane in the PS cage

Ê Insert the Power backplane in the PS cage (1).

Ê Push the Power backplane in direction of the arrow (2) until it engages in the guidances of the PS cage.

Ê Fasten the Power backplane with one screw (see circle).

Figure 72: Installing the PS cage

Ê Push the PS cage from the inside into the housing.

A

Page 92: PRIMERGY TX200 S6 Server - Fujitsu Technology …manuals.ts.fujitsu.com/illustrated_spares/content/TX200_S6/pdf/og.pdf · The PRIMERGY TX200 S6 server is an Intel-based server for

92 Options Guide TX200 S6

Conversion to hot-plug PS and redundant system fans

V CAUTION!

The housing noses (A) must fit in the loops of the PS cage.

Ê Fasten the PS cage with seven screws.

Figure 73: PS cage - Screw inside

Ê Fasten the PS cage inside the housing with one screw.

Page 93: PRIMERGY TX200 S6 Server - Fujitsu Technology …manuals.ts.fujitsu.com/illustrated_spares/content/TX200_S6/pdf/og.pdf · The PRIMERGY TX200 S6 server is an Intel-based server for

TX200 S6 Options Guide 93

Conversion to hot-plug PS and redundant system fans

Figure 74: Power backplane - Connecting the cables

Ê Connect the power cable T26139-Y3997-V1/A3C40101525 to the connector X3 (1) on the Power backplane.

Ê Connect the power cable T26139-Y3952-V451/A3C40101318 to the connector X2 (2) on the Power backplane.

Ê Connect the power cable T26139-Y3986-V401/A3C40101635 to the connector X4 (3) on the Power backplane.

Ê Connect the power cable T26139-Y3758-V8/A3C40057456 to the connector X1 (4) on the Power backplane.

Ê Route the power cables in the cable clamps in the same way as the power cables of the standard power supply were routed before.

Ê Connect the power cables to the system board (see the cabling plans in the Appendix).

Ê Connect the power cables to the drives and the HDD backplanes (see the cabling plans in the Appendix).

Ê Push both power supply modules in the bays of the PS cage until they engage (description see the operating manual).

Page 94: PRIMERGY TX200 S6 Server - Fujitsu Technology …manuals.ts.fujitsu.com/illustrated_spares/content/TX200_S6/pdf/og.pdf · The PRIMERGY TX200 S6 server is an Intel-based server for

94 Options Guide TX200 S6

Conversion to hot-plug PS and redundant system fans

Ê Install the redundant system fan 1&3 and connect both fan cables to the system board as described in the section "Installing system fan 1 (or 1&3)" on page 101.

I The redundant system fan 1&3 (dual fan, two fans are integrated internally) is taller and has two fan cables.

Ê Install the redundant system fan 2&4 and connect both fan cables to the system board as described in the section "Installing system fan 2 (or 2&4)" on page 102.

I The redundant system fan 2&4 (dual fan, two fans are integrated internally) has two fan cables.

V CAUTION!

For safety reasons (danger of tipping) an anti-tilt bracket must be mounted on the rear side of floorstand models with hot-plug power supply.

Ê Place the server on the anti-tilt bracket.

Ê Fasten the anti-tilt bracket using the two knurled screws (see figure 75 on page 95).

Ê Close the server, connect it to the power outlet, and switch it on as described in the chapter "Completion" on page 101.

Page 95: PRIMERGY TX200 S6 Server - Fujitsu Technology …manuals.ts.fujitsu.com/illustrated_spares/content/TX200_S6/pdf/og.pdf · The PRIMERGY TX200 S6 server is an Intel-based server for

TX200 S6 Options Guide 95

11 Conversion from a floorstand model to a rack model

V CAUTION!

Follow the safety instructions in the chapter "Safety instructions" on page 19.

Figure 75: Removing the anti-tilt bracket

Ê Remove the two knurled screws (1).

Ê Lift the server slightly and remove the anti-tilt bracket.

I The anti-tilt bracket is no longer required.

Ê Open the server as described in the chapter "Preparation" on page 27.

Ê Remove the front cover as described in the section "Removing the front cover" on page 29.

I The front cover is no longer required.

Page 96: PRIMERGY TX200 S6 Server - Fujitsu Technology …manuals.ts.fujitsu.com/illustrated_spares/content/TX200_S6/pdf/og.pdf · The PRIMERGY TX200 S6 server is an Intel-based server for

96 Options Guide TX200 S6

Conversion from a floorstand model to a rack model

Figure 76: Removing the screws from the right-hand side cover

Ê Remove the two screws on the rear of the server.

Figure 77: Removing the right-hand side cover

Ê Lift the hook up slightly using a screwdriver.

Page 97: PRIMERGY TX200 S6 Server - Fujitsu Technology …manuals.ts.fujitsu.com/illustrated_spares/content/TX200_S6/pdf/og.pdf · The PRIMERGY TX200 S6 server is an Intel-based server for

TX200 S6 Options Guide 97

Conversion from a floorstand model to a rack model

Ê Push the right-hand side cover in the direction of the arrow.

Ê Lift off the right-hand side cover.

I The right-hand side cover is no longer required.

Ê Lay the server on its right-hand side.

V CAUTION!

Get a second person to help you do this. The server can weigh up to 35 kg.

Figure 78: Removing the foot mounting rail

Ê Loosen the three screws (1) of the foot mounting rail.

Ê Slide the foot mounting rail backward (2) until the hooks disengage.

Ê Take off the foot mounting rail.

I The foot mounting rail is no longer required.

The drive cage for the accessible drives is constructed in such a way that the accessible drives and the front panel module can be taken out simply, turned through 90° to the left, and then be reinstalled.

Ê Remove the dummy covers from the drive cage (figure 22 on page 54).

Ê Unplug the cables from the system board or the accessible drives and remove the drives from the drive cage.

Page 98: PRIMERGY TX200 S6 Server - Fujitsu Technology …manuals.ts.fujitsu.com/illustrated_spares/content/TX200_S6/pdf/og.pdf · The PRIMERGY TX200 S6 server is an Intel-based server for

98 Options Guide TX200 S6

Conversion from a floorstand model to a rack model

Ê Pull the front panel module forward out of its mounting location until you can pull the front panel cable and the USB cable out of the front panel module.

Ê Remove the front panel cable and the USB cable.

Ê Remove the front panel module.

Ê Turn the front panel module through 90° to the left.

Ê Push the front panel module halfway into the upper bay of the drive cage.

Ê Connect the front panel cable and the USB cable to the front panel module.

Figure 79: Installing the front panel module

Ê Now push the front panel module fully into the upper bay of the drive cage.

Ê Turn the drives removed beforehand through 90° to the left.

Ê Turn the dummy covers removed beforehand through 90° to the left.

Ê Install the drives and dummy covers in the drive cage.

Ê Reestablish all connections to the drives.

Page 99: PRIMERGY TX200 S6 Server - Fujitsu Technology …manuals.ts.fujitsu.com/illustrated_spares/content/TX200_S6/pdf/og.pdf · The PRIMERGY TX200 S6 server is an Intel-based server for

TX200 S6 Options Guide 99

Conversion from a floorstand model to a rack model

Figure 80: Removing the screw of the side lock

Ê Remove the screw.

Figure 81: Removing the side lock

Ê Pull the side lock inward (1) and downward (2) and take it out.

I The side lock and the screw are no longer required.

Page 100: PRIMERGY TX200 S6 Server - Fujitsu Technology …manuals.ts.fujitsu.com/illustrated_spares/content/TX200_S6/pdf/og.pdf · The PRIMERGY TX200 S6 server is an Intel-based server for

100 Options Guide TX200 S6

Conversion from a floorstand model to a rack model

Ê Attach the rack front cover as described in the section "Attaching the rack front cover" on page 105.

Figure 82: Attaching the caution label

Ê Attach the enclosed caution label as shown in the photo (except for the Japanese market).

Ê Close the server as described in the chapter "Completion" on page 101.

Ê Install the rack model in the rack as described in the operating manual.

To enable the rack model to be shown correctly in ServerView Management user interfaces, proceed as follows:

Ê Boot the system from the ServerView Suite DVD1. The ServerView Installation Manager is started.

Ê In the first window, select your preferred GUI language.

Ê Select "No status backup" under "Status backup media", and continue by choosing "Continue".

Ê Select "Maintenance".

Ê Select "Server Configuration Manager".

Ê Activate the box for the rack model and store the setting with choosing "Save".

Page 101: PRIMERGY TX200 S6 Server - Fujitsu Technology …manuals.ts.fujitsu.com/illustrated_spares/content/TX200_S6/pdf/og.pdf · The PRIMERGY TX200 S6 server is an Intel-based server for

TX200 S6 Options Guide 101

12 CompletionV CAUTION!

Follow the safety instructions in the chapter "Safety instructions" on page 19.

12.1 System fans

12.1.1 Installing system fan 1 (or 1&3)

The standard system fan 1 is shorter and has just one fan cable; the redundant system fan 1&3 (dual fan, two fans are integrated internally) is taller and has two fan cables. The procedure for installing both system fans is identical except for connecting the fan cables.

Figure 83: Example: Installing system fan 1&3

Ê Put the hooks of system fan 1 (or 1&3) into the recesses on the server’s rear side (1).

Page 102: PRIMERGY TX200 S6 Server - Fujitsu Technology …manuals.ts.fujitsu.com/illustrated_spares/content/TX200_S6/pdf/og.pdf · The PRIMERGY TX200 S6 server is an Intel-based server for

102 Options Guide TX200 S6

Completion

Ê Push system fan 1 (or 1&3) in the direction of the arrow until the lock engages (2).

Ê Connect the fan cable to the connector FAN1 (if there is a second fan cable, connect this to connector FAN3) on the system board.

12.1.2 Installing system fan 2 (or 2&4)

The standard system fan 2 has just one fan cable; the redundant system fan 2&4 (dual fan, two fans are integrated internally) has two fan cables. The procedure for installing both system fans is identical except for connecting the fan cables.

Ê Connect the fan cable to the connector FAN2 (if there is a second fan cable, connect this to connector FAN4) on the system board.

Figure 84: Example: Installing system fan 2&4

Ê Carefully insert (1) the air duct with the integrated system fan 2 (or 2&4).

Make sure that the locks of the air duct engage (2) in the housing bracket and in the recess of the fixing plate (standard power supply) or the power supply cage (redundant power supply).

Page 103: PRIMERGY TX200 S6 Server - Fujitsu Technology …manuals.ts.fujitsu.com/illustrated_spares/content/TX200_S6/pdf/og.pdf · The PRIMERGY TX200 S6 server is an Intel-based server for

TX200 S6 Options Guide 103

Completion

12.2 Floorstand model

12.2.1 Attaching the front cover

Reattach the front cover after installing/removing accessible drives.

Figure 85: Attaching the front cover

Ê Carefully hook in the front cover on the right side.

Ê Close the front cover. Make sure that the three locks engage.

Page 104: PRIMERGY TX200 S6 Server - Fujitsu Technology …manuals.ts.fujitsu.com/illustrated_spares/content/TX200_S6/pdf/og.pdf · The PRIMERGY TX200 S6 server is an Intel-based server for

104 Options Guide TX200 S6

Completion

12.2.2 Closing the server

Figure 86: Attaching the left-hand side cover

Ê Pull the locking lever as far as it will go and insert the side cover in the five recesses (see circles) on the housing (1).

Ê Push the side cover against the housing and push down the locking lever (2) at the same time.

Closing the locking lever pushes the side cover forwards and the hooks on the upper edge of the side cover engage.

Ê Insert the key.

Ê Lock the server.

Ê Connect all power plugs to the power outlets.

Ê Press the On/Off button to start up the server.

Page 105: PRIMERGY TX200 S6 Server - Fujitsu Technology …manuals.ts.fujitsu.com/illustrated_spares/content/TX200_S6/pdf/og.pdf · The PRIMERGY TX200 S6 server is an Intel-based server for

TX200 S6 Options Guide 105

Completion

12.3 Rack model

12.3.1 Attaching the rack front cover

Reattach the rack front cover after implementing the following routines:

– Installing/removing accessible drives– Conversion from a floorstand model to a rack model

Figure 87: Attaching the rack front cover

Ê Attach the rack front cover, together with the plastic front cover, from the front (1).

V CAUTION!

The rack front cover brackets are marked "Left" and "Right". Position the bracket marked "Left" on the left of the rack front.

Ê Attach the rack front cover using two screws on each side (2).

Page 106: PRIMERGY TX200 S6 Server - Fujitsu Technology …manuals.ts.fujitsu.com/illustrated_spares/content/TX200_S6/pdf/og.pdf · The PRIMERGY TX200 S6 server is an Intel-based server for

106 Options Guide TX200 S6

Completion

12.3.2 Closing the server

Ê Pull the locking lever as far as it will go and insert the top cover in the five recesses on the housing (see also figure 86 on page 104).

Ê Push the top cover against the housing and push down the locking lever at the same time.

Closing the locking lever pushes the top cover forwards and the hooks on the right edge of the top cover engage.

If you have not removed the server from the rack cabinet, please skip steps 1-4.

V CAUTION!

At least two people are required to install the server in the rack cabinet.

Do not use the handles on the rack front cover to lift the server into the rack.

Figure 88: Inserting the server (a)

Page 107: PRIMERGY TX200 S6 Server - Fujitsu Technology …manuals.ts.fujitsu.com/illustrated_spares/content/TX200_S6/pdf/og.pdf · The PRIMERGY TX200 S6 server is an Intel-based server for

TX200 S6 Options Guide 107

Completion

Figure 89: Inserting the server (b)

Ê Extend the telescopic rails completely to the front (1).

I They must click into place so that they can no longer be moved.

Ê Lower the server from above onto the projecting telescopic rails (2), (3). As you do this, the locking bar (4) engages.

Ê Push the locking mechanism of both telescopic rails up (5).

Ê For a final function test, slide the server in and out twice. The rails should move smoothly.

Ê Push the server as far as it will go into the rack (6).

Ê Fasten the server to the rack (7) using the two knurled screws (front panel).

Ê Connect all cables on the rear of the server.

Ê Connect all power plugs to the power outlets.

Ê Press the On/Off button to start up the server.

Page 108: PRIMERGY TX200 S6 Server - Fujitsu Technology …manuals.ts.fujitsu.com/illustrated_spares/content/TX200_S6/pdf/og.pdf · The PRIMERGY TX200 S6 server is an Intel-based server for

108 Options Guide TX200 S6

Completion

Page 109: PRIMERGY TX200 S6 Server - Fujitsu Technology …manuals.ts.fujitsu.com/illustrated_spares/content/TX200_S6/pdf/og.pdf · The PRIMERGY TX200 S6 server is an Intel-based server for

TX200 S6 Options Guide 109

13 Appendix

13.1 Cabling

You will find suggestions for cabling on the next pages.

Page 110: PRIMERGY TX200 S6 Server - Fujitsu Technology …manuals.ts.fujitsu.com/illustrated_spares/content/TX200_S6/pdf/og.pdf · The PRIMERGY TX200 S6 server is an Intel-based server for

110 Options Guide TX200 S6

Appendix

Figure 90: Example 1: Standard PS, fan, SMB, intrusion, COM2

Le

ge

nd

:

Po

we

r

SA

TA

/S

AS

US

B

Da

ta

PBLA3C40086258

AT

XP

WR

1P

WR

2

CP

U2

PC98

SA

TA

6

PW

R3

SATA

MLC1

Frontpanel

FA

N 2

Slo

t1

Slo

t2

Slo

t3

Slo

t4

Slo

t6

Slo

t5

Batt

ery

FAN1SYSFAN 1

FAN 3

USB1 USB Front

CP

U1

KK

B9

12

KK

B9

11

KK

B9

10

SA

TA

5

US

BS

tick

US

SD

1E

1D

2D

2E

2F

1F

2B

2C

1C

1B

1A

2A

FA

N 4

Intr

TP

M

Fro

nt

pan

el

SA

TA

DV

D-R

om

SA

TA

/T

ap

ed

riv

e/

op

tio

nal

SA

TA

/T

ap

ed

riv

e/

op

tio

nal

KK

B9

12

K6

44

-B

83

3

PW

R1

PW

R2

PW

R3

Hard

dis

k3

Hard

dis

k2

Hard

dis

k1

K9

90

-B

40

4

X6

X1

Hard

dis

k0

P5

P1

5

P1

6

P1

8

P1

9

P1

2

P1

1

P1

7

P10

P1

4

P4

Intr

.

Intr

.

P1

3

Po

wer

Su

pp

lyE

54

4-V

70

Y3736-V

302

/A

3C

40102748

Y3589-V

651

/A

3C

40071502

Slo

t7

CO

M2

Chassis

ID

SMB

Y3

71

8-V

5/

A3

C40

08

75

92

A3

C4

00

96

56

4

K6

44

-B

43

5

-*

-Y

15

5L

SP

/LS

D/

op

tio

nal

Page 111: PRIMERGY TX200 S6 Server - Fujitsu Technology …manuals.ts.fujitsu.com/illustrated_spares/content/TX200_S6/pdf/og.pdf · The PRIMERGY TX200 S6 server is an Intel-based server for

TX200 S6 Options Guide 111

Appendix

Figure 91: Example 2: SATA hard disks, SAS/SATA/USB tape, control panel

Le

ge

nd

:

Po

we

r

SA

TA

/S

AS

US

B

Da

ta

PBLA3C40086258

AT

XP

WR

1P

WR

2

CP

U2

SA

TA

6

PW

R3

SATA

MLC1

Frontpanel

Slo

t2

Slo

t3

Slo

t4

Slo

t6

Slo

t5

Slo

t7

Batt

ery

FAN1SYSFAN 1

FAN 3

USB1USB2

USB Front

Raid

Key

CP

U1

KK

B9

12

KK

B9

11

KK

B9

10

SA

TA

5

US

BS

tick

US

SD

1E

1D

2D

2E

2F

1F

2B

2C

1C

1B

1A

2A

Intr

Fro

ntp

an

el

SA

TA

DV

D-R

om

SA

S/

Tap

ed

riv

e/

op

tio

nal

US

B /

Tap

e d

riv

e/

op

tio

nal

KK

B9

12

LS

P/L

SD

/o

pti

on

al

K6

44

-B

43

5

-*

-Y

15

5

K6

44

-B

83

3

Hard

dis

k3

Hard

dis

k2

Hard

dis

k1

K9

90

-B

40

4

X6

X1

Hard

dis

k0

Po

wer

Su

pp

lyE

54

4-V

70

Y3969-V

202

/A

3C

40101507

Y3928-V205 /A3C40103930

Y3925-V501/A3C40101670

Slo

t1

SA

S-R

aid

-C

on

troll

er

Slo

t1

SA

SM

LC

2

SA

SM

LC

1

Y3807-V212/A3C40099071

Y3963-V

101

/A

3C

40069737

Y3969-V202

Y3973-V2/A3C40073691

Page 112: PRIMERGY TX200 S6 Server - Fujitsu Technology …manuals.ts.fujitsu.com/illustrated_spares/content/TX200_S6/pdf/og.pdf · The PRIMERGY TX200 S6 server is an Intel-based server for

112 Options Guide TX200 S6

Appendix

Figure 92: Example 3: SAS 3.5-inch HDD extension box, iBBU

Le

ge

nd

:

Po

we

r

SA

TA

/S

AS

US

B

Da

ta

AT

XP

WR

1P

WR

2

CP

U2

PC98

PW

R3

Frontpanel

FA

N2

Slo

t1

Slo

t2

Slo

t3

Slo

t4

Slo

t6

Slo

t5

Slo

t7

Batt

ery

FAN1SYSFAN 1

FAN 3

USB1USB2

Raid

Key

CP

U1

KK

B9

12

KK

B9

11

KK

B9

10

US

SD

1E

1D

2D

2E

2F

1F

2B

2C

1C

1B

1A

2A

FA

N4

Intr

Fro

nt

pan

el

KK

B9

12

K6

44

-B

83

3

Hard

dis

k3

Hard

dis

k2

Hard

dis

k1

K9

90

-B

40

4

X6

X1

Hard

dis

k0

SA

TA

/ D

VD

0,5

Hard

dis

k4

Hard

dis

k5

LS

P/L

SD

/ o

pti

on

al

Tap

ed

riv

e/

op

tio

nal

PBLA3C40086258

K6

44

-B

61

1-*

-Y

15

5

A3C40086258

X5

X14

SA

S-R

aid

-C

on

troll

er

Slo

t1

iBB

U

SA

SM

LC

2

SA

SM

LC

1

P4

P1

8P

19

P1

7 P5

PW

R1

PW

R2

PW

R3

P1

1P

12

P1

3

P1

6

P10

Y3

98

7-V

2/

A3

C40

09

04

54

Y3963-V

101

/A

3C

40069737

Y3925-V501/A3C40101670

Po

wer

Su

pp

lyE

54

4-V

70

Y3963-V

202

/A

3C

40089270

P1

5P

14

Page 113: PRIMERGY TX200 S6 Server - Fujitsu Technology …manuals.ts.fujitsu.com/illustrated_spares/content/TX200_S6/pdf/og.pdf · The PRIMERGY TX200 S6 server is an Intel-based server for

TX200 S6 Options Guide 113

Appendix

Figure 93: Example 4: SAS 2.5-inch HDD extension box, iBBU

Le

ge

nd

:

Po

we

r

SA

TA

/S

AS

US

B

Da

ta

AT

XP

WR

1P

WR

2

CP

U2

PW

R3

Frontpanel

FA

N2

Slo

t1

Slo

t3

Slo

t4

Slo

t6

Slo

t5

Slo

t7

Batt

ery

FAN1SYSFAN 1

FAN 3

USB1USB2

Raid

Key

CP

U1

KK

B9

12

KK

B9

11

KK

B9

10

1E

1D

2D

2E

2F

1F

2B

2C

1C

1B

1A

2A

FA

N4

Intr

Fro

nt

pan

el

KK

B9

12

K6

44

-B

83

3

Tap

ed

riv

e/

op

tio

nal

SA

S-R

aid

-C

on

troll

er

Slo

t1

iBB

U

SA

SM

LC

2

SA

SM

LC

1

P1

7

PW

R1

PW

R2

PW

R3

P1

2

P1

5

Y3

98

7-V

2/

A3

C40

09

04

54

Y3963-V

103

/A

3C

40089197

Slo

t1

SA

S-R

aid

-C

on

troll

er

Slo

t2

SA

SM

LC

2

SA

SM

LC

1

P1

8

P1

9

Y3963-V

103

/A

3C

40089197

Y3963-V

102

/A

3C

40087289

Y3963-V

102

/A

3C

40087289

2,5“SASHDD0

2,5“SASHDD1

2,5“SASHDD2

2,5“SASHDD3

2,5“SASHDD4

2,5“SASHDD5

2,5“SASHDD6

2,5“SASHDD7

A3C

40086493

2x

Backpla

ne

C2

63

61

-K

83

5-B

27

6

2,5“SASHDD0

2,5“SASHDD1

2,5“SASHDD2

2,5“SASHDD3

2,5“SASHDD4

2,5“SASHDD5

2,5“SASHDD6

2,5“SASHDD7

A3C

40086493

2x

Backpla

ne

C2

63

61

-K

83

5-B

28

9

P4

P5

P1

3

P1

6

X1

X1

X6

X6

X1

X1

X6

X6

iBB

U

Y3

98

7-V

2/

A3

C40

09

04

54

Po

wer

Su

pp

lyE

54

4-V

70

P1

1

P1

4

Page 114: PRIMERGY TX200 S6 Server - Fujitsu Technology …manuals.ts.fujitsu.com/illustrated_spares/content/TX200_S6/pdf/og.pdf · The PRIMERGY TX200 S6 server is an Intel-based server for

114 Options Guide TX200 S6

Appendix

Figure 94: Example 5: Redundant PS/fan, SAS 3.5-inch HDD extension box

Le

ge

nd

:

Po

we

r

SA

TA

/S

AS

US

B

Da

ta

PW

R2

CP

U2

PC98

PW

R3

Frontpanel

Slo

t1

Slo

t2

Slo

t3

Slo

t4

Slo

t6

Slo

t5

Slo

t7

Batt

ery

FAN3SYS

USB1

CP

U1

KK

B9

12

KK

B9

10

US

SD

1E

1D

2D

2E

2F

1F

2B

2C

1C

1B

1A

2A

Intr

Fro

nt

pan

el

KK

B9

12

K6

44

-B

83

3

Hard

dis

k3

Hard

dis

k2

Hard

dis

k1

K9

90

-B

40

4

X6

X1

Hard

dis

k0

SA

TA

/ D

VD

0,5

Hard

dis

k4

Hard

dis

k5

LS

P/L

SD

/ o

pti

on

al

Tap

ed

riv

e/

op

tio

nal

PBLA3C40086258A3C40086258

X5

X14

SA

S-R

aid

-C

on

troll

er

Slo

t1

SA

SM

LC

2

SA

SM

LC

1

P4

P5

P10

Y3963-V

101

/A

3C

40069737

Y3963-V

202

/A

3C

40089270

FAN1SYS

FAN 1

FAN 3

FA

N 2

FA

N 4

X4

X2

red

.P

SU

2

DP

S-8

00G

B-2

A

red

.P

SU

1

DP

S-8

00G

B-2

A

PW

R1

PW

R2

AT

XP

WR

1

Y3952-V451

Y3

75

8-V

8

A3C

40057456

X1

BP

LA

3C

40100500

A3C40101318

X4

X3

P1

9

P1

7Y

3986-V

401

Y3997-V1/A3C40101525

A3C40101635

K6

44

-B

61

1-*

-Y

15

5

P1

8

P1

3

P1

6

P1

1P

12

P1

4P

15

Page 115: PRIMERGY TX200 S6 Server - Fujitsu Technology …manuals.ts.fujitsu.com/illustrated_spares/content/TX200_S6/pdf/og.pdf · The PRIMERGY TX200 S6 server is an Intel-based server for

TX200 S6 Options Guide 115

Appendix

Figure 95: Example 6: Redundant PS/fan, SAS 2.5-inch HDD extension box

Le

ge

nd

:

Po

we

r

SA

TA

/S

AS

US

B

Da

ta

PW

R2

CP

U2

PW

R3

Frontpanel

Slo

t3

Slo

t4

Slo

t6

Slo

t5

Slo

t7

Batt

ery

FAN3SYS

USB1

CP

U1

KK

B9

12

KK

B9

10

1E

1D

2D

2E

2F

1F

2B

2C

1C

1B

1A

2A

Intr

Fro

nt

pan

el

KK

B9

12

K6

44

-B

83

3

Tap

ed

riv

e/

op

tio

nal

FAN1SYS

FAN 1

FAN 3

FA

N 2

FA

N 4

X4

X2

red

.P

SU

2

DP

S-8

00G

B-2

A

red

.P

SU

1

DP

S-8

00G

B-2

A

PW

R1

PW

R2

AT

XP

WR

1

Y3952-V451

X1

BP

LA

3C

40100500

A3C40101318

X4

P1

1P

12

P1

4P

15

P1

7

P1

8

P1

9

2,5“SASHDD0

2,5“SASHDD1

2,5“SASHDD2

2,5“SASHDD3

2,5“SASHDD4

2,5“SASHDD5

2,5“SASHDD6

2,5“SASHDD7

A3C

40086493

2x

Backpla

ne

C2

63

61

-K

83

5-B

27

6

2,5“SASHDD0

2,5“SASHDD1

2,5“SASHDD2

2,5“SASHDD3

2,5“SASHDD4

2,5“SASHDD5

2,5“SASHDD6

2,5“SASHDD7

A3C

40086493

2x

Backpla

ne

C2

63

61

-K

83

5-B

28

9

X1

X6

Slo

t1

SA

S-R

aid

-C

on

troll

er

Slo

t1

SA

SM

LC

2

SA

SM

LC

1

Slo

t1

SA

S-R

aid

-C

on

troll

er

Slo

t2

SA

SM

LC

2

SA

SM

LC

1Y

3963-V

103

/A

3C

40089197

Y3963-V

103

/A

3C

40089197

P1

3

X1

X6

X6

P1

6 X1

P5

X6

X1

P4

P10

X3

Y3986-V

401

Y3997-V1/A3C40101525

Y3

75

8-V

8

A3C

40057456

Y3963-V

102

/A

3C

40087289

Y3963-V

102

/A

3C

40087289

Page 116: PRIMERGY TX200 S6 Server - Fujitsu Technology …manuals.ts.fujitsu.com/illustrated_spares/content/TX200_S6/pdf/og.pdf · The PRIMERGY TX200 S6 server is an Intel-based server for

116 Options Guide TX200 S6

Appendix

Page 117: PRIMERGY TX200 S6 Server - Fujitsu Technology …manuals.ts.fujitsu.com/illustrated_spares/content/TX200_S6/pdf/og.pdf · The PRIMERGY TX200 S6 server is an Intel-based server for

TX200 S6 Options Guide 117

IndexAaccessible drives 13, 52

equipping bays 53

BBBU 77

Cconversion of floorstand model to rack

model 14, 95conversion standard PS to hot-plug

PS 14, 87

Ddual operation 42, 48

Eelectrostatic-sensitive devices

(ESD) 26equipping bays 53expansion card 14, 73

HHDD extension box 13heat sink 50

Iinformation, additional 12installing the slimline DVD 60

Llaser information 25light emitting diode (LED) 25lithium battery 23LSD 13, 52LSP 13, 52

Mmain memory 13, 38meaning of the symbols 15multi-processor operating

system 42, 48

Nnotational conventions 15

Pprocessor 13, 42

Ssecond serial connector 14, 85ServerView Local Service

Display 13ServerView Local Service Panel 13system fan 1, 1&3

removing 35system fan 2, 2&4

removing 34

Ttarget group 11TPM 14, 81Trusted Platform Module 14, 81

UUFM 14, 83upgrade standard system fan to

redundant system fans 14, 87USB Flash Module 14, 83

Page 118: PRIMERGY TX200 S6 Server - Fujitsu Technology …manuals.ts.fujitsu.com/illustrated_spares/content/TX200_S6/pdf/og.pdf · The PRIMERGY TX200 S6 server is an Intel-based server for

118 Options Guide TX200 S6

Index