66
Options Guide - English PRIMERGY TX100 S2 Options Guide July 2010

PRIMERGY TX100 S2 Server - Fujitsumanuals.ts.fujitsu.com/file/9432/tx100s2-og-en.pdf · TX100 S2 Options Guide Before reading this manual ... – "D2779 BIOS Setup Utility for PRIMERGY

  • Upload
    dinhdan

  • View
    227

  • Download
    0

Embed Size (px)

Citation preview

Page 1: PRIMERGY TX100 S2 Server - Fujitsumanuals.ts.fujitsu.com/file/9432/tx100s2-og-en.pdf · TX100 S2 Options Guide Before reading this manual ... – "D2779 BIOS Setup Utility for PRIMERGY

Options Guide - English

PRIMERGY TX100 S2 Options Guide

July 2010

Page 2: PRIMERGY TX100 S2 Server - Fujitsumanuals.ts.fujitsu.com/file/9432/tx100s2-og-en.pdf · TX100 S2 Options Guide Before reading this manual ... – "D2779 BIOS Setup Utility for PRIMERGY

Comments… Suggestions… Corrections…The User Documentation Department would like toknow your opinion of this manual. Your feedback helpsus optimize our documentation to suit your individual needs.

Feel free to send us your comments by e-mail to email: [email protected].

Certified documentation according to DIN EN ISO 9001:2008To ensure a consistently high quality standard anduser-friendliness, this documentation was created tomeet the regulations of a quality management system which complies with the requirements of the standardDIN EN ISO 9001:2008.

cognitas. Gesellschaft für Technik-Dokumentation mbHwww.cognitas.de

Copyright and TrademarksCopyright © 2010 Fujitsu Technology Solutions GmbH.

All rights reserved.Delivery subject to availability; right of technical modifications reserved.

All hardware and software names used are trademarks of their respective manufacturers.

– The contents of this manual may be revised without prior notice.

– Fujitsu assumes no liability for damages to third party copyrights or other rights arising from the use of any information in this manual.

– No part of this manual may be reproduced in any form without the prior written permission of Fujitsu.

Microsoft, Windows, Windows Server, and Hyper V are trademarks or registered trademarks of Microsoft Corporation in the USA and other countries.

Intel and Xeon are trademarks or registered trademarks of Intel Corporation or its subsidiaries in the USA and other countries.

Page 3: PRIMERGY TX100 S2 Server - Fujitsumanuals.ts.fujitsu.com/file/9432/tx100s2-og-en.pdf · TX100 S2 Options Guide Before reading this manual ... – "D2779 BIOS Setup Utility for PRIMERGY

TX100 S2 Options Guide

Before reading this manual

For your safety

This manual contains important information for safely and correctly using this product.

Carefully read the manual before using this product. Pay particular attention to the accompanying manual "Safety Notes and Regulations" and ensure these safety notes are understood before using the product. Keep this manual and the manual "Safety Notes and Regulations" in a safe place for easy reference while using this product.

Radio interference

This product is a "Class A" ITE (Information Technology Equipment). In a domestic environment this product may cause radio interference, in which case the user may be required to take appropriate measures. VCCI-A

Aluminum electrolytic capacitors

The aluminum electrolytic capacitors used in the product's printed circuit board assemblies and in the mouse and keyboard are limited-life components. Use of these components beyond their operating life may result in electrolyte leakage or depletion, potentially causing emission of foul odor or smoke.

As a guideline, in a normal office environment (25°C) operating life is not expected to be reached within the maintenance support period (5 years). However, operating life may be reached more quickly if, for example, the product is used in a hot environment. The customer shall bear the cost of replacing replaceable components which have exceeded their operating life. Note that these are only guidelines, and do not constitute a guarantee of trouble-free operation during the maintenance support period.

High safety use

This product has been designed and manufactured for general uses such as general office use, personal use, domestic use and normal industrial use. It has not been designed or manufactured for uses which demand an extremely high level of safety and carry a direct and serious risk to life or body if such safety cannot be ensured.

Page 4: PRIMERGY TX100 S2 Server - Fujitsumanuals.ts.fujitsu.com/file/9432/tx100s2-og-en.pdf · TX100 S2 Options Guide Before reading this manual ... – "D2779 BIOS Setup Utility for PRIMERGY

Options Guide TX100 S2

These uses include control of nuclear reactions in nuclear power plants, automatic airplane flight control, air traffic control, traffic control in mass transport systems, medical devices for life support, and missile guidance control in weapons systems (hereafter, "high safety use"). Customers should not use this product for high safety use unless measures are in place for ensuring the level of safety demanded of such use. Please consult the sales staff of Fujitsu if intending to use this product for high safety use.

Measures against momentary voltage drop

This product may be affected by a momentary voltage drop in the power supply caused by lightning. To prevent a momentary voltage drop, use of an AC uninterruptible power supply is recommended.

(This notice follows the guidelines of Voltage Dip Immunity of Personal Computer issued by JEITA, the Japan Electronics and Information Technology Industries Association.)

Technology controlled by the Foreign Exchange and Foreign Trade Control Law of Japan

Documents produced by Fujitsu may contain technology controlled by the Foreign Exchange and Foreign Trade Control Law of Japan. Documents which contain such technology should not be exported from Japan or transferred to non-residents of Japan without first obtaining authorization in accordance with the above law.

Harmonic Current Standards

This product conforms to harmonic current standard JIS C 61000-3-2.

Only for the Japanese market:About SATA hard disk drives

The SATA version of this server supports hard disk drives with SATA / BC-SATA storage interfaces. Please note that the usage and operation conditions differ depending on the type of hard disk drive used.

Please refer to the following internet address for further information on the usage and operation conditions of each available type of hard disk drive:

http://primeserver.fujitsu.com/primergy/harddisk/

Page 5: PRIMERGY TX100 S2 Server - Fujitsumanuals.ts.fujitsu.com/file/9432/tx100s2-og-en.pdf · TX100 S2 Options Guide Before reading this manual ... – "D2779 BIOS Setup Utility for PRIMERGY

TX100 S2 Options Guide

Only for the Japanese market:

I Although described in this manual, some sections do not apply to the Japanese market. These options and routines include:

– USB Flash Module (UFM)

Page 6: PRIMERGY TX100 S2 Server - Fujitsumanuals.ts.fujitsu.com/file/9432/tx100s2-og-en.pdf · TX100 S2 Options Guide Before reading this manual ... – "D2779 BIOS Setup Utility for PRIMERGY

Options Guide TX100 S2

Page 7: PRIMERGY TX100 S2 Server - Fujitsumanuals.ts.fujitsu.com/file/9432/tx100s2-og-en.pdf · TX100 S2 Options Guide Before reading this manual ... – "D2779 BIOS Setup Utility for PRIMERGY

TX100 S2 Options Guide

Contents

1 Introduction . . . . . . . . . . . . . . . . . . . . . . . . . . . . 9

1.1 Concept and target groups . . . . . . . . . . . . . . . . . . . 9

1.2 Documentation overview . . . . . . . . . . . . . . . . . . . 10

1.3 Expansions and upgrades . . . . . . . . . . . . . . . . . . . 11

1.4 Notational conventions . . . . . . . . . . . . . . . . . . . . 12

2 Procedure . . . . . . . . . . . . . . . . . . . . . . . . . . . . 13

3 Safety instructions . . . . . . . . . . . . . . . . . . . . . . . 15

4 Preparation . . . . . . . . . . . . . . . . . . . . . . . . . . . 23

4.1 Opening the server . . . . . . . . . . . . . . . . . . . . . . . 23

4.2 Removing the air duct . . . . . . . . . . . . . . . . . . . . . 27

5 Main memory . . . . . . . . . . . . . . . . . . . . . . . . . . 29

5.1 Equipping rules . . . . . . . . . . . . . . . . . . . . . . . . . 29

5.2 Extending/replacing the main memory . . . . . . . . . . . . 31

6 Accessible drives . . . . . . . . . . . . . . . . . . . . . . . 33

6.1 Preparation . . . . . . . . . . . . . . . . . . . . . . . . . . . 33

6.2 Installing an accessible 5.25-inch drive . . . . . . . . . . . . 35

7 Non-accessible drives . . . . . . . . . . . . . . . . . . . . . 37

7.1 Installing and removing the hard disk drives . . . . . . . . . 37

Page 8: PRIMERGY TX100 S2 Server - Fujitsumanuals.ts.fujitsu.com/file/9432/tx100s2-og-en.pdf · TX100 S2 Options Guide Before reading this manual ... – "D2779 BIOS Setup Utility for PRIMERGY

Options Guide TX100 S2

Contents

8 Expansion cards and parallel interface . . . . . . . . . . . . 43

8.1 Installing an expansion card . . . . . . . . . . . . . . . . . . 45

8.2 Installing a parallel interface cable . . . . . . . . . . . . . . . 47

8.3 Installing TPM (optional) . . . . . . . . . . . . . . . . . . . . 50

8.4 Installing the UFM (optional) . . . . . . . . . . . . . . . . . . 53

9 Completion . . . . . . . . . . . . . . . . . . . . . . . . . . . . 55

9.1 Installing the air duct . . . . . . . . . . . . . . . . . . . . . . 55

9.2 Closing the server . . . . . . . . . . . . . . . . . . . . . . . . 56

10 Appendix . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 59

10.1 Cabling . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 59

Index . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 65

Page 9: PRIMERGY TX100 S2 Server - Fujitsumanuals.ts.fujitsu.com/file/9432/tx100s2-og-en.pdf · TX100 S2 Options Guide Before reading this manual ... – "D2779 BIOS Setup Utility for PRIMERGY

TX100 S2 Options Guide 9

1 IntroductionThe PRIMERGY TX100 S2 server is an Intel-based server for workgroups and small networks. The server is suitable for use as a file server and also as an application, information or Internet server.

Thanks to its highly developed hardware and software components, the PRIMERGY TX100 S2 server offers a high level of data security and availability.

Security functions in the BIOS-Setup and on the system board protect the data on the server against manipulation. The supported RAID levels allow the hard disk controllers to offer error tolerance, through data redundancy, for users who want to provide complete protection for valuable data.

Its low noise level and high energy efficiency make it ideal for office environments.

1.1 Concept and target groups

This Options Guide shows you how to extend and upgrade your server.

V CAUTION!

The activities described in this manual may only be performed by technical specialists.

I The installation and removal of the hot-plug components is described in the Operating Manual supplied with the server.

The PRIMERGY TX100 S2 has a power management function that reduces power consumption to <65 W in typical configurations. The server thus satisfies the requirements of the U.S. Environmental Protection Agency (EPA).

Page 10: PRIMERGY TX100 S2 Server - Fujitsumanuals.ts.fujitsu.com/file/9432/tx100s2-og-en.pdf · TX100 S2 Options Guide Before reading this manual ... – "D2779 BIOS Setup Utility for PRIMERGY

10 Options Guide TX100 S2

Introduction

1.2 Documentation overview

More information on your PRIMERGY TX100 S2 can be found in the following documents:

– "Quick Start Hardware - PRIMERGY TX100 S2" leaflet (included as a printed copy)

– "Quick Start Software - Quick Installation Guide" DVD booklet (included with the PRIMERGY ServerView Suite as a printed copy)

– "Safety notes and other important information" manual

– "Warranty" manual

– "Returning used devices" manual

– "Helpdesk" leaflet

– Technical manual for the system board D2779

– "PRIMERGY TX100 S2 Server Operating Manual"

– "PRIMERGY TX100 S2 Server Options Guide"

– "D2779 BIOS Setup Utility for PRIMERGY TX100 S2" manual

I PRIMERGY manuals are available in PDF format on the ServerView Suite DVD 2. The ServerView Suite DVD 2 is part of the ServerView Suite supplied with every server.

If you no longer have the ServerView Suite DVDs, you can obtain the relevant current versions using the order number U15000-C289 (the order number for the Japanese market: please refer to the configurator of the server http://primeserver.fujitsu.com/primergy/system.html).

The PDF files of the manuals can also be downloaded free of charge from the Internet. The overview page showing the online documentation available on the Internet can be found using the URL (for EMEA market): http://manuals.ts.fujitsu.com. The PRIMERGY server documentation can be accessed using the Industry standard servers navigation option.

For the Japanese market please use the URL: http://primeserver.fujitsu.com/primergy/manual.html.

Page 11: PRIMERGY TX100 S2 Server - Fujitsumanuals.ts.fujitsu.com/file/9432/tx100s2-og-en.pdf · TX100 S2 Options Guide Before reading this manual ... – "D2779 BIOS Setup Utility for PRIMERGY

TX100 S2 Options Guide 11

Introduction

Further sources of information:

– PRIMERGY Abbreviations and Glossary on the ServerView Suite DVD 2– Manual for the monitor– Documentation for the boards and drives– Operating system documentation– Information files in your operating system

1.3 Expansions and upgrades

Upgrading the main memory

The system board supports up to 16 GB of main memory. There are 4 slots available for the main memory. The slots can be fitted with 1 GB, 2 GB and 4 GB DDR3 1066/1333 MHz (unbuffered) DIMM modules (with ECC).

Additional accessible drives

There is one free 5.25-inch bay for an additional accessible drive. The first (upper) bay already contains a DVD drive.

Slots for expansion cards

The server can be flexibly expanded via four slots:

– Two PCIe Gen2 x 8 slots– One PCIe Gen2 x 4 slot– One PCI slot

Parallel interface for printers

As an option, a parallel interface can be provided for printers.

Page 12: PRIMERGY TX100 S2 Server - Fujitsumanuals.ts.fujitsu.com/file/9432/tx100s2-og-en.pdf · TX100 S2 Options Guide Before reading this manual ... – "D2779 BIOS Setup Utility for PRIMERGY

12 Options Guide TX100 S2

Introduction

Trusted Platform Module (TPM)

I The system board is optional equipped with a TPM (Trusted Platform Module) by the manufacturer. This module enables programs from third party manufacturers to store key information (e.g. drive encryption using Window's Bitlocker Drive Encryption).

The TPM is activated via the BIOS system (for more information, refer to the BIOS manual).

USB Flash Module (UFM)

The server can be equipped with a USB Flash Module (UFM).

This module can be used as optional memory for software (e.g. VMware) or as a software dongle.

1.4 Notational conventions

The following notational conventions are used in this manual:

Text in italics indicates commands or menu items.

"Quotation marks" indicate names of chapters and terms that are being emphasized.

Ê describes activities that must be performed in the order shown.

V CAUTION! pay particular attention to texts marked with this symbol. Failure to observe this warning may endanger your life, destroy the system or lead to the loss of data.

I indicates additional information, notes and tips.

Page 13: PRIMERGY TX100 S2 Server - Fujitsumanuals.ts.fujitsu.com/file/9432/tx100s2-og-en.pdf · TX100 S2 Options Guide Before reading this manual ... – "D2779 BIOS Setup Utility for PRIMERGY

TX100 S2 Options Guide 13

Procedure

2 ProcedureV CAUTION!

● The actions described in this manual should only be carried out by technical specialists.

● Equipment repairs should only be performed by service staff. Please note that unauthorized interference with the system will void the warranty and exempt the manufacturer from all liability.

● Any failure to observe the guidelines in this manual, and any improper repairs could expose the user to risks (electric shock, energy hazards, fire hazards) or damage the equipment.

Ê First of all, carefully read the safety instructions in chapter "Safety instructions" on page 15 and following.

Ê Make sure that all necessary manuals (see section "Documentation overview" on page 10) are available; print the PDF files if required. Most importantly, you will need the operating manual for the server and the technical manual for the system board.

Ê Shut the server down correctly, switch it off, disconnect the power plugs and open the server as described in chapter "Preparation" on page 23.

Ê Carry out the expansion or upgrade of your server as described in the pertinent chapter.

Ê Close the server, connect it to the power outlet, and switch it on as described in chapter "Completion" on page 55.

Ê Start the operating system and make the appropriate configuration if necessary (see Operating Manual).

Page 14: PRIMERGY TX100 S2 Server - Fujitsumanuals.ts.fujitsu.com/file/9432/tx100s2-og-en.pdf · TX100 S2 Options Guide Before reading this manual ... – "D2779 BIOS Setup Utility for PRIMERGY

14 Options Guide TX100 S2

Procedure

Page 15: PRIMERGY TX100 S2 Server - Fujitsumanuals.ts.fujitsu.com/file/9432/tx100s2-og-en.pdf · TX100 S2 Options Guide Before reading this manual ... – "D2779 BIOS Setup Utility for PRIMERGY

TX100 S2 Options Guide 15

3 Safety instructionsI The following safety instructions are also provided in the manual "Safety

Notes and Regulations".

This device meets the relevant safety regulations for IT equipment. If you have any questions about whether you can install the server in the intended environment, please contact your sales outlet or our customer service team.

V CAUTION!

● The actions described in this manual should only be carried out by technical specialists.

● Equipment repairs should only be performed by service staff. Please note that unauthorized interference with the system will void the warranty and exempt the manufacturer from all liability.

● Any failure to observe the guidelines in this manual, and any improper repairs could expose the user to risks (electric shock, energy hazards, fire hazards) or damage the equipment.

Page 16: PRIMERGY TX100 S2 Server - Fujitsumanuals.ts.fujitsu.com/file/9432/tx100s2-og-en.pdf · TX100 S2 Options Guide Before reading this manual ... – "D2779 BIOS Setup Utility for PRIMERGY

16 Options Guide TX100 S2

Safety instructions

Before starting up

V CAUTION!

● During installation and before operating the device, observe the instructions on environmental conditions for your device.

● If the device is brought in from a cold to a warm environment, condensation may form both inside and on the outside of the device.

Wait until the device has acclimatized to room temperature and is absolutely dry before starting it up. Material damage may be caused to the device if this requirement is not observed.

● Transport the device only in the original packaging or in packaging that protects it from knocks and jolts.

Installation and operation

V CAUTION!

● The device may only be operated at a maximum ambient temperature of 35°C.

● If the device is integrated in an installation that receives power from an industrial (public) power supply network with the IEC309 connector, the (public) power supply protection must comply with the requirements for non-industrial (public) power supply networks for the type A connector.

● The unit automatically adjusts itself to a mains voltage in a range of 100 V - 240 V. Ensure that the local mains voltage lies within these limits.

● This device must only be connected to properly grounded shock-proof sockets with tested and approved power cables.

● Ensure that the device is connected to a grounded power outlet close to the device.

Page 17: PRIMERGY TX100 S2 Server - Fujitsumanuals.ts.fujitsu.com/file/9432/tx100s2-og-en.pdf · TX100 S2 Options Guide Before reading this manual ... – "D2779 BIOS Setup Utility for PRIMERGY

TX100 S2 Options Guide 17

Safety instructions

V CAUTION!

● Ensure that the power sockets on the device and the grounded power outlet are freely accessible.

● The On/Off button or the main power switch (if there is one) does not disconnect the device from the mains voltage. To completely disconnect it, you must remove all the power plugs from the power outlets.

● Always connect the server and the attached peripherals to the same power circuit. Otherwise you run the risk of losing data if, for example, the server is still running but a peripheral device (e.g. memory subsystem) fails during a power outage.

● Data cables must be adequately shielded to avoid interference.

● The EN 50173 and EN 50174-1/2 standards apply for LAN cabling. The minimum requirement is the use of a category 5 screened LAN cable for 10/100 Mbit/s Ethernet, or a category 5e cable for Gigabit Ethernet. The requirements from the ISO/IEC 11801 specification must also be met.

● Route the cables in such a way that they do not form a potential hazard (tripping) and cannot be damaged. When connecting the device, refer to the relevant notes in the operating manual.

● Do not connect or disconnect any data transmission cables during a thunderstorm (lightning hazard).

● Make sure that no objects (e.g. bracelets or paper clips) fall into or liquids spill into the device (risk of electric shock or short circuit).

● In emergencies (e.g. damaged casing, control elements or power cable, penetration of liquids or foreign bodies), switch off the device immediately, unplug it from the grounded power outlets, and contact your customer service center.

Page 18: PRIMERGY TX100 S2 Server - Fujitsumanuals.ts.fujitsu.com/file/9432/tx100s2-og-en.pdf · TX100 S2 Options Guide Before reading this manual ... – "D2779 BIOS Setup Utility for PRIMERGY

18 Options Guide TX100 S2

Safety instructions

V CAUTION!

● Proper operation of the device (in accordance with

IEC 60950-1/EN 60950-1) is only ensured if the casing is fully assembled and the rear covers for the installation bays are in place (electric shock, cooling, fire protection, interference suppression).

● Install only system extensions that satisfy the requirements and rules governing safety, electromagnetic compatibility, and telecommunications terminal equipment. If you install other extensions, you may damage the system or violate these safety regulations. You can find out which system extensions are suitable from the customer service center or your sales outlet.

● The components marked with a warning label (e.g. lightning symbol) may only be opened, removed or exchanged by authorized, qualified personnel.

● If you cause a defect on the device by installing or exchanging system extensions, the warranty will be invalidated.

● Only set the resolutions and refresh rates specified in the operating manual for your monitor. Otherwise, you may damage the monitor. If you are in any doubt, contact your sales outlet or customer service center.

Batteries

V CAUTION!

● Incorrect replacement of batteries may result in a risk of explosion. The batteries may only be replaced with identical batteries or with a type recommended by the manufacturer (see the Technical Manual for the system board).

● Replace the lithium battery on the system board in accordance with the instructions in the Technical Manual for the system board.

Page 19: PRIMERGY TX100 S2 Server - Fujitsumanuals.ts.fujitsu.com/file/9432/tx100s2-og-en.pdf · TX100 S2 Options Guide Before reading this manual ... – "D2779 BIOS Setup Utility for PRIMERGY

TX100 S2 Options Guide 19

Safety instructions

Working with CDs/DVDs/BDs and optical drives

When working with devices with optical drives, these instructions must be followed.

V CAUTION!

● Only use CDs/DVDs/BDs that are in perfect condition, in order to prevent data loss, equipment damage and injury.

● Check each CD/DVD/BD for damage, cracks, breakages etc. before inserting it in the drive.

Note that any additional labels applied may change the mechanical properties of a CD/DVD/BD and cause imbalance.

Damaged and imbalanced CDs/DVDs/BDs can break at high drive speeds (data loss).

Under certain circumstances, sharp CD/DVD/BD fragments can pierce the cover of the optical drive (equipment damage) and can fly out of the device (danger of injury, particularly to uncovered body parts such as the face or neck).

● High humidity and airborne dust levels are to be avoided. Electric shocks and/or server failures may be caused by liquids such as water, or metallic items, such as paper clips, entering a drive.

● Shocks and vibrations are also to be avoided.

● Do not insert any objects other than the specified CDs/DVDs/BDs.

● Do not pull on, press hard, or otherwise handle the CD/DVD/BD tray roughly.

● Do not disassemble the optical drive.

● Before use, clean the optical disk tray using a soft, dry cloth.

● As a precaution, remove disks from the optical drive when the drive is not to be used for a long time. Keep the optical disk tray closed to prevent foreign matter, such as dust, from entering the optical drive.

● Hold CDs/DVDs/BDs by their edges to avoid contact with the disk surface.

Page 20: PRIMERGY TX100 S2 Server - Fujitsumanuals.ts.fujitsu.com/file/9432/tx100s2-og-en.pdf · TX100 S2 Options Guide Before reading this manual ... – "D2779 BIOS Setup Utility for PRIMERGY

20 Options Guide TX100 S2

Safety instructions

● Do not contaminate the CD/DVD/BD surface with fingerprints, oil, dust, etc. If dirty, clean with a soft, dry cloth, wiping from the center to the edge. Do not use benzene, thinners, water, record sprays, antistatic agents, or silicone-impregnated cloth.

● Be careful not to damage the CD/DVD/BD surface.

● Keep the CDs/DVDs/BDs away from heat sources.

● Do not bend or place heavy objects on CDs/DVDs/BDs.

● Do not write with ballpoint pen or pencil on the label (printed) side.

● Do not attach stickers or similar to the label side. Doing so may cause rotational eccentricity and abnormal vibrations.

● When a CD/DVD/BD is moved from a cold place to a warm place, moisture condensation on the CD/DVD/BD surface can cause data read errors. In this case, wipe the CD/DVD/BD with a soft, dry cloth then let it air dry. Do not dry the CD/DVD/BD using devices such as a hair dryer.

● To avoid dust, damage, and deformation, keep the CD/DVD/BD in its case whenever it is not in use.

● Do not store CDs/DVDs/BDs at high temperatures. Areas exposed to prolonged direct sunlight or near heating appliances are to be avoided.

I You can prevent damage from the optical drive and the CDs/DVDs/BDs, as well as premature wear of the disks, by observing the following suggestions:

– Only insert disks in the drive when needed and remove them after use.

– Store the disks in suitable sleeves.– Protect the disks from exposure to heat and direct sunlight.

Laser information

The optical drive complies with IEC 60825-1 laser class 1.

V CAUTION!

The optical drive contains a light-emitting diode (LED), which under certain circumstances produces a laser beam stronger than laser class 1. Looking directly at this beam is dangerous.

Never remove parts of the optical drive casing!

Page 21: PRIMERGY TX100 S2 Server - Fujitsumanuals.ts.fujitsu.com/file/9432/tx100s2-og-en.pdf · TX100 S2 Options Guide Before reading this manual ... – "D2779 BIOS Setup Utility for PRIMERGY

TX100 S2 Options Guide 21

Safety instructions

Modules with Electrostatic-Sensitive Devices

Modules with electrostatic-sensitive devices are identified by the following sticker:

Figure 1: ESD label

When you handle components fitted with ESDs, you must always observe the following points:

● Switch off the system and remove the power plugs from the power outlets before installing or removing components with ESDs.

● You must always discharge static build-up (e.g. by touching a grounded object) before working with such components.

● Any devices or tools that are used must be free of electrostatic charge.

● Wear a suitable grounding cable that connects you to the external chassis of the system unit.

● Always hold components with ESDs at the edges or at the points marked green (touch points).

● Do not touch any connectors or conduction paths on an ESD.

● Place all the components on a pad which is free of electrostatic charge.

I For a detailed description of how to handle ESD components, see the relevant European or international standards (EN 61340-5-1, ANSI/ESD S20.20).

Page 22: PRIMERGY TX100 S2 Server - Fujitsumanuals.ts.fujitsu.com/file/9432/tx100s2-og-en.pdf · TX100 S2 Options Guide Before reading this manual ... – "D2779 BIOS Setup Utility for PRIMERGY

22 Options Guide TX100 S2

Safety instructions

Page 23: PRIMERGY TX100 S2 Server - Fujitsumanuals.ts.fujitsu.com/file/9432/tx100s2-og-en.pdf · TX100 S2 Options Guide Before reading this manual ... – "D2779 BIOS Setup Utility for PRIMERGY

TX100 S2 Options Guide 23

4 PreparationV CAUTION!

Follow the safety instructions in the chapter "Safety instructions" on page 15.

4.1 Opening the server

Ê Terminate all applications and shut down the server correctly.

Ê If your operating system has not switched off the server, press the on/off button for minimum 4 seconds.

Ê Disconnect the power plug from the grounded power outlet.

Ê If required, remove the lock on the side cover.

Ê Lay the server on its left side (as seen from the front).

Removing the side cover

Figure 2: Opening the locking lever

Ê Pull the locking lever as far as it will go.

Page 24: PRIMERGY TX100 S2 Server - Fujitsumanuals.ts.fujitsu.com/file/9432/tx100s2-og-en.pdf · TX100 S2 Options Guide Before reading this manual ... – "D2779 BIOS Setup Utility for PRIMERGY

24 Options Guide TX100 S2

Preparation

Figure 3: Removing the side cover

Ê Lift up the side cover (1).

Ê Remove the side cover (2).

Page 25: PRIMERGY TX100 S2 Server - Fujitsumanuals.ts.fujitsu.com/file/9432/tx100s2-og-en.pdf · TX100 S2 Options Guide Before reading this manual ... – "D2779 BIOS Setup Utility for PRIMERGY

TX100 S2 Options Guide 25

Preparation

Lifting up the drive cage

Figure 4: Lifting up the drive cage

Ê Loosen the knurled screw (1).

Page 26: PRIMERGY TX100 S2 Server - Fujitsumanuals.ts.fujitsu.com/file/9432/tx100s2-og-en.pdf · TX100 S2 Options Guide Before reading this manual ... – "D2779 BIOS Setup Utility for PRIMERGY

26 Options Guide TX100 S2

Preparation

Figure 5: Lifting up the drive cage

Ê Lift up the drive cage.

I It is not a failure though the drive cage might not be lifted easily so that the hinge of the drive cage may become hard when the drive cage is lifted. Please lift the drive cage putting power while noting it as it is.

I The built-in torque controller ensures that the drive cage stays up in any position.

Page 27: PRIMERGY TX100 S2 Server - Fujitsumanuals.ts.fujitsu.com/file/9432/tx100s2-og-en.pdf · TX100 S2 Options Guide Before reading this manual ... – "D2779 BIOS Setup Utility for PRIMERGY

TX100 S2 Options Guide 27

Preparation

4.2 Removing the air duct

I When removing the air duct, make sure that you do not damage the heat sink on the system board.

Figure 6: Removing the air duct

Ê Open the server (see section "Opening the server" on page 23).

Ê Unhook the cables from the brackets on the air duct.

Ê Remove any connected cables that are impeding your work.

Ê Unlock the air duct by pressing the locking clip in the direction of the arrow (1).

Ê While keeping the locking clip pressed, lift the air duct out of its housing in the direction of the arrow (2).

Page 28: PRIMERGY TX100 S2 Server - Fujitsumanuals.ts.fujitsu.com/file/9432/tx100s2-og-en.pdf · TX100 S2 Options Guide Before reading this manual ... – "D2779 BIOS Setup Utility for PRIMERGY

28 Options Guide TX100 S2

Preparation

Page 29: PRIMERGY TX100 S2 Server - Fujitsumanuals.ts.fujitsu.com/file/9432/tx100s2-og-en.pdf · TX100 S2 Options Guide Before reading this manual ... – "D2779 BIOS Setup Utility for PRIMERGY

TX100 S2 Options Guide 29

5 Main memoryV CAUTION!

Follow the safety instructions in the chapter "Safety instructions" on page 15.

The system board supports up to 16 GB of main memory. 4 slots (2 memory banks with 2 slots each) are provided for the main memory. Every slot can be fitted with DDR3 UDIMMs with ECC with 1 GB, 2 GB or 4 GB.

5.1 Equipping rules

The system board has four slots for memory modules. For dual-channel operation the memory modules must be equipped in pairs and color coded, starting from the bottom to the top.

Blue slots: DIMM 1A (1) and DIMM 1B (2)

Black slots: DIMM 2A (3) and DIMM 2B (4)

Figure 7: Configuration of the main memory

– Each memory bank is equipped with two memory modules with the same capacity.

– The module capacity between pairs can differ: pair 1A/1B can be populated with two 1 GB modules and pair 2A/2B with two 2 GB modules.

1B

1A

2B

2A

Page 30: PRIMERGY TX100 S2 Server - Fujitsumanuals.ts.fujitsu.com/file/9432/tx100s2-og-en.pdf · TX100 S2 Options Guide Before reading this manual ... – "D2779 BIOS Setup Utility for PRIMERGY

30 Options Guide TX100 S2

Main memory

● Minimum required for booting the system is one UDIMM (socket DIMM 1A).

● Therefore, memory boards must be fitted with UDIMMs as follows.

The maximum performance can be achieved in a symmetric dual-channel configuration. Therefore, both channels have to be populated with the same amount of memory. The DRAM device technology may vary from one channel to the other.

If the amount of memory differs between the two channels, the system board will run in dual-channel asymmetric mode.

Regardless of the mode, all DIMMs will run at the highest common frequency that is allowed by the SPD data of the DIMMs and the maximum speed of the selected configuration.

Configuration 1: single-channel configuration

Configuration 2:

The dual-channel mode is only activated, if the size of the used memory module in socket DIMM 1B is equal to the summary of the memory modules in the sockets DIMM 1A and DIMM 2A(e.g. DIMM 1A = 1GB, DIMM 2A = 1GB, DIMM 1B = 2GB).

Configuration 3 and 4:For dual-channel configuration arrange identical memory modules in pairs of the sockets.Install identical memory modules in sockets DIMM 1A and DIMM 1B and identical memory modules in sockets DIMM 2A and DIMM 2B.

Mode Configuration DIMM 1A black

DIMM 2A blue

DIMM 1B black

DIMM 2B blue

Single-channel

1 populated - - - - - -

Single-/dual-channel

2 populated populated populated - -

Dual-channel

3 populated - - populated - -

Dual-channel

4 populated - - populated populated

Table 1: Configuration of the main memory

Page 31: PRIMERGY TX100 S2 Server - Fujitsumanuals.ts.fujitsu.com/file/9432/tx100s2-og-en.pdf · TX100 S2 Options Guide Before reading this manual ... – "D2779 BIOS Setup Utility for PRIMERGY

TX100 S2 Options Guide 31

Main memory

5.2 Extending/replacing the main memory

Ê Open the server (see section "Opening the server" on page 23).

Ê Remove the air duct (see section "Removing the air duct" on page 27).

Figure 8: Removing a memory module

Ê Press the holders on either side of the mounting location concerned outward (1).

Ê If the slot was equipped: pull the memory module out of the slot (2).

Figure 9: Inserting a memory module

Ê Carefully press the memory module into the slot (3) until the fastening tabs on both sides of it engage (4).

Ê Install the air duct (see section "Installing the air duct" on page 55).

Ê Close the server (see section "Closing the server" on page 56), connect it to the power outlet, and switch it on.

I If the memory size has changed, run BIOS Setup for confirming this change.

44

3

Page 32: PRIMERGY TX100 S2 Server - Fujitsumanuals.ts.fujitsu.com/file/9432/tx100s2-og-en.pdf · TX100 S2 Options Guide Before reading this manual ... – "D2779 BIOS Setup Utility for PRIMERGY

32 Options Guide TX100 S2

Main memory

Page 33: PRIMERGY TX100 S2 Server - Fujitsumanuals.ts.fujitsu.com/file/9432/tx100s2-og-en.pdf · TX100 S2 Options Guide Before reading this manual ... – "D2779 BIOS Setup Utility for PRIMERGY

TX100 S2 Options Guide 33

6 Accessible drivesV CAUTION!

Follow the safety instructions in the chapter "Safety instructions" on page 15.

Two 5.25-inch bays are available for accessible drives. DVD drives or magnetic tape drives can be installed in these slots.

By default, the upper slot is fitted with a DVD drive.

6.1 Preparation

Ê Open the server (see section "Opening the server" on page 23).

Ê Remove the dummy module.

Removing the dummy module

Figure 10: Removing the screws of the dummy module

Ê Unscrew the two screws.

Page 34: PRIMERGY TX100 S2 Server - Fujitsumanuals.ts.fujitsu.com/file/9432/tx100s2-og-en.pdf · TX100 S2 Options Guide Before reading this manual ... – "D2779 BIOS Setup Utility for PRIMERGY

34 Options Guide TX100 S2

Accessible drives

Figure 11: Removing the dummy module

Ê Push the dummy module with a screw driver (1) a little bit out of the housing and then pull the dummy module out of the housing (2).

Page 35: PRIMERGY TX100 S2 Server - Fujitsumanuals.ts.fujitsu.com/file/9432/tx100s2-og-en.pdf · TX100 S2 Options Guide Before reading this manual ... – "D2779 BIOS Setup Utility for PRIMERGY

TX100 S2 Options Guide 35

Accessible drives

6.2 Installing an accessible 5.25-inch drive

Figure 12: Installing a drive

Ê Fit the new drive about halfway into the bay (1).

Ê Connect the data cable to the accessible drive (see the cabling plans in the Appendix).

Ê Connect the power cable to the accessible drive (see the cabling plans in the Appendix).

Ê Fit the drive right into the bay.

Ê Secure the drive with two screws (2).

Ê Close the server (see section "Closing the server" on page 56), connect it to the power outlet, and switch it on.

V CAUTION!

Keep the dummy module for future use. If you remove the accessible drive again and do not replace it with a new one, the dummy module must be reinstalled to comply with EMC regulations and to satisfy cooling requirements and fire protection measures.

Page 36: PRIMERGY TX100 S2 Server - Fujitsumanuals.ts.fujitsu.com/file/9432/tx100s2-og-en.pdf · TX100 S2 Options Guide Before reading this manual ... – "D2779 BIOS Setup Utility for PRIMERGY

36 Options Guide TX100 S2

Accessible drives

Page 37: PRIMERGY TX100 S2 Server - Fujitsumanuals.ts.fujitsu.com/file/9432/tx100s2-og-en.pdf · TX100 S2 Options Guide Before reading this manual ... – "D2779 BIOS Setup Utility for PRIMERGY

TX100 S2 Options Guide 37

7 Non-accessible drives

7.1 Installing and removing the hard disk drives

Ê Shut down the server and disconnect the AC power cord from the system.

Ê Remove the side cover as described in section "Preparation" on page 23

Ê Open the HDD cage as described in section "Preparation" on page 23.

Figure 13: Removing HDD cables

Ê Remove all cables from the desired hard disk drive.

I In 4-HDD configurations, when replacing hard disk drives 3 and / or 4, you will also need to disconnect cables from hard disk drives 1 and / or 2 (see orange arrows).

Page 38: PRIMERGY TX100 S2 Server - Fujitsumanuals.ts.fujitsu.com/file/9432/tx100s2-og-en.pdf · TX100 S2 Options Guide Before reading this manual ... – "D2779 BIOS Setup Utility for PRIMERGY

38 Options Guide TX100 S2

Non-accessible drives

Figure 14: Detaching an HDD

Ê Press in on the locking latches on both Easyclick rails to unlatch the defective hard disk drive.

Figure 15: Removing an HDD

Page 39: PRIMERGY TX100 S2 Server - Fujitsumanuals.ts.fujitsu.com/file/9432/tx100s2-og-en.pdf · TX100 S2 Options Guide Before reading this manual ... – "D2779 BIOS Setup Utility for PRIMERGY

TX100 S2 Options Guide 39

Non-accessible drives

Ê Remove the defective hard disk drive from its installation bay.

Figure 16: Removing HDD Easyclick rails

Ê Remove the Easyclick rails (C26316-K716-C370) from the defective hard disk drive.

Figure 17: Mounting HDD Easyclick rails (A)

Page 40: PRIMERGY TX100 S2 Server - Fujitsumanuals.ts.fujitsu.com/file/9432/tx100s2-og-en.pdf · TX100 S2 Options Guide Before reading this manual ... – "D2779 BIOS Setup Utility for PRIMERGY

40 Options Guide TX100 S2

Non-accessible drives

Ê Align the three pins on the Easyclick rails with the screw holes on the hard disk drive.

Figure 18: Mounting HDD Easyclick rails (B)

Ê Attach an Easyclick rail on each side of the new hard disk drive.

Figure 19: Installing an HDD

Page 41: PRIMERGY TX100 S2 Server - Fujitsumanuals.ts.fujitsu.com/file/9432/tx100s2-og-en.pdf · TX100 S2 Options Guide Before reading this manual ... – "D2779 BIOS Setup Utility for PRIMERGY

TX100 S2 Options Guide 41

Non-accessible drives

Ê Insert the new hard disk drive into its installation bay and push in until the locking latches engage.

Figure 20: Connecting HDD cables

Ê Reconnect all cables to the hard disk drives (see the cabling plans in the appendix of the PRIMERGY TX100 S2 Options Guide).

Ê Close the HDD cage as described in section "Preparation" on page 23.

Ê Close the side cover as described in section "Completion" on page 55and reconnect the AC power cord.

Page 42: PRIMERGY TX100 S2 Server - Fujitsumanuals.ts.fujitsu.com/file/9432/tx100s2-og-en.pdf · TX100 S2 Options Guide Before reading this manual ... – "D2779 BIOS Setup Utility for PRIMERGY

42 Options Guide TX100 S2

Non-accessible drives

Page 43: PRIMERGY TX100 S2 Server - Fujitsumanuals.ts.fujitsu.com/file/9432/tx100s2-og-en.pdf · TX100 S2 Options Guide Before reading this manual ... – "D2779 BIOS Setup Utility for PRIMERGY

TX100 S2 Options Guide 43

8 Expansion cards and parallel interface

V CAUTION!

Follow the safety instructions in the chapter "Safety instructions" on page 15.

The server can be flexibly expanded via four slots.

Figure 21: Arrangement of the slots

I For more information see the Technical Manual of the system board D2779.

Slot Description

1 PCI 32 bit

2 PCIe Gen2 x8

3 PCIe Gen2 x8

4 PCIe Gen2 x4

4

3

2

1

Page 44: PRIMERGY TX100 S2 Server - Fujitsumanuals.ts.fujitsu.com/file/9432/tx100s2-og-en.pdf · TX100 S2 Options Guide Before reading this manual ... – "D2779 BIOS Setup Utility for PRIMERGY

44 Options Guide TX100 S2

Expansion cards and parallel interface

Slot sequence for expansion cards

1.Controller for special slots PCI bus Type

max pcs per system

Preferential slot

Forbidden slot

1. 2. 3.

S26361-D2616-A** (if boot controller)

1 3 1, 2, 4

2.PCI Express controller PCI bus Type

max pcs per system

Preferential slot

Forbidden slot

1. 2. 3.

Intel Pro 1000PT Dual Port Server Adapter x4

1 4 2 3 1

Intel Pro 1000PT Server Adapter x1

2 4 2 3 1

Intel Pro 1000PT Desktop Adapter PCIe x4

2 4 2 3 1

FTS: S26361-D2735 (Kawela)Intel Dual Port PCIe x4

1 4 2 3 1

3.Graphic controller PCI bus Type

max pcs per system

Preferential slot

Forbidden slot

1. 2. 3.

Nvidia NVS290 PCIe x1 1 4 2 3 1

Page 45: PRIMERGY TX100 S2 Server - Fujitsumanuals.ts.fujitsu.com/file/9432/tx100s2-og-en.pdf · TX100 S2 Options Guide Before reading this manual ... – "D2779 BIOS Setup Utility for PRIMERGY

TX100 S2 Options Guide 45

Expansion cards and parallel interface

8.1 Installing an expansion card

Ê Open the server (see section "Opening the server" on page 23).

Figure 22: Removing the slot cover

Ê Remove the screw (see circle).

Ê Remove the slot cover.

V CAUTION!

Keep the slot cover in a safe place. If you remove the expansion card again and do not replace it with a new one, then reinstall the slot cover to comply with EMC regulations and to satisfy cooling requirements and fire protection measures.

Page 46: PRIMERGY TX100 S2 Server - Fujitsumanuals.ts.fujitsu.com/file/9432/tx100s2-og-en.pdf · TX100 S2 Options Guide Before reading this manual ... – "D2779 BIOS Setup Utility for PRIMERGY

46 Options Guide TX100 S2

Expansion cards and parallel interface

Figure 23: Installing an expansion card

Ê Carefully press the new expansion card into the relevant slot on the system board until it clicks into place.

Ê Screw the slot cover for the expansion card into place (see circle).

Ê If necessary, connect the cable to the expansion card and the other components.

Ê Close the server (see section "Closing the server" on page 56), connect it to the power outlet, and switch it on.

Page 47: PRIMERGY TX100 S2 Server - Fujitsumanuals.ts.fujitsu.com/file/9432/tx100s2-og-en.pdf · TX100 S2 Options Guide Before reading this manual ... – "D2779 BIOS Setup Utility for PRIMERGY

TX100 S2 Options Guide 47

Expansion cards and parallel interface

8.2 Installing a parallel interface cable

I This feature is not available for the Japanese market.

Ê Open the server (see section "Opening the server" on page 23).

Ê Remove the screw from the slot cover for slot 1.

Ê Remove the slot cover.

V CAUTION!

Keep the slot cover in a safe place. If you remove the parallel interface again and do not replace it with a new one, then reinstall the slot cover to comply with EMC regulations and to satisfy cooling requirements and fire protection measures.

Figure 24: Extension of the slot cover

Ê Attach an extension bracket with one screw to the slot cover of the parallel interface cable.

Page 48: PRIMERGY TX100 S2 Server - Fujitsumanuals.ts.fujitsu.com/file/9432/tx100s2-og-en.pdf · TX100 S2 Options Guide Before reading this manual ... – "D2779 BIOS Setup Utility for PRIMERGY

48 Options Guide TX100 S2

Expansion cards and parallel interface

Figure 25: Installing a parallel port

Ê Insert the slot cover of the parallel interface cable into slot 1.

Ê Screw the slot cover of the parallel interface cable into place.

Page 49: PRIMERGY TX100 S2 Server - Fujitsumanuals.ts.fujitsu.com/file/9432/tx100s2-og-en.pdf · TX100 S2 Options Guide Before reading this manual ... – "D2779 BIOS Setup Utility for PRIMERGY

TX100 S2 Options Guide 49

Expansion cards and parallel interface

Figure 26: Installing a parallel interface

Ê Connect the parallel interface port to the connector PARALLEL PORT on the system board.

Ê Close the server (see section "Closing the server" on page 56), connect it to the power outlet, and switch it on.

I For the latest installing order see the configurator provided for the TX100 S2:http://primeserver.fujitsu.com/primergy/system.html(for the Japanese market)

Page 50: PRIMERGY TX100 S2 Server - Fujitsumanuals.ts.fujitsu.com/file/9432/tx100s2-og-en.pdf · TX100 S2 Options Guide Before reading this manual ... – "D2779 BIOS Setup Utility for PRIMERGY

50 Options Guide TX100 S2

Expansion cards and parallel interface

8.3 Installing TPM (optional)

The server can be equipped with a TPM (Trusted Platform Module).

Figure 27: TPM installation kit

1 TPM (Trusted Platform Module) 3 Special screw for TPM

2 TPM spacer

I The black TPM spacer is not used in this server.

4 TPM screwdriver insert bit forTPM special screw

� � � �� � � �

Page 51: PRIMERGY TX100 S2 Server - Fujitsumanuals.ts.fujitsu.com/file/9432/tx100s2-og-en.pdf · TX100 S2 Options Guide Before reading this manual ... – "D2779 BIOS Setup Utility for PRIMERGY

TX100 S2 Options Guide 51

Expansion cards and parallel interface

Figure 28: Inserting the TPM spacer on the system board

Ê Insert the TPM spacer into the hole on the system board.

Figure 29: Fastening the TPM

Ê Insert the TPM on the system board (1).

Page 52: PRIMERGY TX100 S2 Server - Fujitsumanuals.ts.fujitsu.com/file/9432/tx100s2-og-en.pdf · TX100 S2 Options Guide Before reading this manual ... – "D2779 BIOS Setup Utility for PRIMERGY

52 Options Guide TX100 S2

Expansion cards and parallel interface

Ê Fasten the TPM with the special screw for the TPM (2).

Please use the TPM screwdriver insert bit to tighten the special screw.

I Do not fasten the screw too tightly (torque value of 0.6 Nm: for EMEA market).

V CAUTION

The system board has to be removed in order to loosen the TMP screw. Use a thin slotted screwdriver (e.g. watchmaker's screwdriver) to remove the screw.

I You can find information on configuring the TPM in the "D2779 BIOS Setup Utility for TX100 S2" manual.

Page 53: PRIMERGY TX100 S2 Server - Fujitsumanuals.ts.fujitsu.com/file/9432/tx100s2-og-en.pdf · TX100 S2 Options Guide Before reading this manual ... – "D2779 BIOS Setup Utility for PRIMERGY

TX100 S2 Options Guide 53

Expansion cards and parallel interface

8.4 Installing the UFM (optional)

The server can be equipped with a USB Flash Module (UFM).

Figure 30: UFM installation kit

1 USB Flash Module (UFM) 3 UFM spacer

2 UFM nylon screw

Page 54: PRIMERGY TX100 S2 Server - Fujitsumanuals.ts.fujitsu.com/file/9432/tx100s2-og-en.pdf · TX100 S2 Options Guide Before reading this manual ... – "D2779 BIOS Setup Utility for PRIMERGY

54 Options Guide TX100 S2

Expansion cards and parallel interface

Figure 31: UFM - Position on the system boarder

Ê Connect the USB Flash Module to the system board (1). The spacer must click into the hole on the system board (2).

Page 55: PRIMERGY TX100 S2 Server - Fujitsumanuals.ts.fujitsu.com/file/9432/tx100s2-og-en.pdf · TX100 S2 Options Guide Before reading this manual ... – "D2779 BIOS Setup Utility for PRIMERGY

TX100 S2 Options Guide 55

9 CompletionV CAUTION!

Follow the safety instructions in the chapter "Safety instructions" on page 15.

9.1 Installing the air duct

I When installing the air duct, make sure that you do not damage the heat sink on the system board.

Figure 32: Installing the air duct

Ê Place the air duct on the heat sink.

Ê Push the air duct towards the front of the server until it clicks into the locking mechanism.

Ê Lock the cables in the brackets of the air duct.

Ê Connect the three power cables with the system board.

Page 56: PRIMERGY TX100 S2 Server - Fujitsumanuals.ts.fujitsu.com/file/9432/tx100s2-og-en.pdf · TX100 S2 Options Guide Before reading this manual ... – "D2779 BIOS Setup Utility for PRIMERGY

56 Options Guide TX100 S2

Completion

9.2 Closing the server

Closing the drive cage

Figure 33: Closing the drive cage

Ê Close the drive cage.

Ê Use the knurled screw (1) to screw the drive cage into place.

Page 57: PRIMERGY TX100 S2 Server - Fujitsumanuals.ts.fujitsu.com/file/9432/tx100s2-og-en.pdf · TX100 S2 Options Guide Before reading this manual ... – "D2779 BIOS Setup Utility for PRIMERGY

TX100 S2 Options Guide 57

Completion

Installing the side cover

Figure 34: Installing the side cover

Ê Replace the side cover.

Ê Press the locking lever down until it clicks into place.

Ê Put the server back into the upright position.

Ê Connect all cables on the rear of the server.

Ê Connect the power plug to the grounded power outlet.

Ê Press the On/Off button to start up the server.

Page 58: PRIMERGY TX100 S2 Server - Fujitsumanuals.ts.fujitsu.com/file/9432/tx100s2-og-en.pdf · TX100 S2 Options Guide Before reading this manual ... – "D2779 BIOS Setup Utility for PRIMERGY
Page 59: PRIMERGY TX100 S2 Server - Fujitsumanuals.ts.fujitsu.com/file/9432/tx100s2-og-en.pdf · TX100 S2 Options Guide Before reading this manual ... – "D2779 BIOS Setup Utility for PRIMERGY

TX100 S2 Options Guide 59

10 Appendix

10.1 Cabling

You will find suggestions for cabling on the next pages.

Page 60: PRIMERGY TX100 S2 Server - Fujitsumanuals.ts.fujitsu.com/file/9432/tx100s2-og-en.pdf · TX100 S2 Options Guide Before reading this manual ... – "D2779 BIOS Setup Utility for PRIMERGY

60 Options Guide TX100 S2

Cabling Appendix

Figure 35: Power cables and fans

Po

we

r

SA

S

FD

D

Da

ta

Le

ge

nd

:

US

B

I2C

SA

TA

Pa

ralle

l/S

eri

ell

Ad

ap

ter

Intr

usio

n

PS

UE

55

1-

V7

0

Fro

ntfa

n

Fro

ntp

an

el

US

Bfr

on

t

Op

tica

lD

rive

(To

p)

Op

tica

lD

rive

(Bo

tto

m)

HD

D1

HD

D3

HD

D2

HD

D4

T26139-Y3942-V221

UF

M

Fro

nt

----

-B

ackup

AU

X

64

2

53

1

P1

P9

P8

P4

P3

P2

no

tu

se

d

T2

61

39

-Y3

70

1-V

14

7

T2

61

39

-Y3

89

4-V

51

3

P6

P7

T2

61

39

-Y3

94

2-V

1

US

BD

AT

/RD

XD

rive

(Bo

tto

m)

alte

rna

tive

Page 61: PRIMERGY TX100 S2 Server - Fujitsumanuals.ts.fujitsu.com/file/9432/tx100s2-og-en.pdf · TX100 S2 Options Guide Before reading this manual ... – "D2779 BIOS Setup Utility for PRIMERGY

TX100 S2 Options Guide 61

Appendix Cabling

Figure 36: Data cables with 2 HDD subsystem

Po

we

r

SA

S

FD

D

Da

ta

Le

ge

nd

:

US

B

I2C

SA

TA

Pa

ralle

l/S

eri

ell

Ad

ap

ter

Intr

usio

n

Fro

ntfa

n

Fro

ntp

an

el

US

Bfr

on

t

Op

tica

lD

rive

(To

p)

US

BD

rive

(Bo

tto

m)

HD

D1

UF

M

Fro

nt

----

-B

ackup

AU

X

64

2

53

1

P4

P3

T2

61

39

-Y3

70

1-V

14

7

T2

61

39

-Y3

89

4-V

51

3

2x

T2

61

39

-Y3

95

9-V

10

5

T2

61

39

-Y3

95

8-V

20

2

T2

61

39

-Y3

97

3-V

2

HD

D2

Page 62: PRIMERGY TX100 S2 Server - Fujitsumanuals.ts.fujitsu.com/file/9432/tx100s2-og-en.pdf · TX100 S2 Options Guide Before reading this manual ... – "D2779 BIOS Setup Utility for PRIMERGY

Figure 37: Data cables with 4 HDD subsystem

Po

we

r

SA

S

FD

D

Da

ta

Le

ge

nd

:

US

B

I2C

SA

TA

Pa

ralle

l/S

eri

ell

Ad

ap

ter

Intr

usio

n

Fro

ntfa

n

Fro

ntp

an

el

US

Bfr

on

t

Op

tica

lD

rive

1

(To

p)

Op

tica

lD

rive

2

(Bo

tto

m)

HD

D1

HD

D3

UF

M

Fro

nt

----

-B

acku

p

AU

X

64

2

53

1

P4

P3

T2

61

39

-Y3

70

1-V

14

7

T2

61

39

-Y3

89

4-V

51

3

2x

T2

61

39

-Y3

95

9-V

10

5

T2

61

39

-Y3

95

8-V

20

2

T2

61

39

-Y3

95

8-V

20

2

HD

D2

HD

D4

2x

T2

61

39

-Y3

95

9-V

10

5

Page 63: PRIMERGY TX100 S2 Server - Fujitsumanuals.ts.fujitsu.com/file/9432/tx100s2-og-en.pdf · TX100 S2 Options Guide Before reading this manual ... – "D2779 BIOS Setup Utility for PRIMERGY

TX100 S2 Options Guide 63

Appendix Cabling

Figure 38: Power cables, parallel port and fans

Po

we

r

SA

S

FD

D

Da

ta

Le

ge

nd

:

US

B

I2C

SA

TA

Pa

ralle

l/S

eri

ell

Ad

ap

ter

Intr

usio

n

PS

UE

55

1-

V7

0

Fro

ntfa

n

Re

ar

fan

Fro

ntp

an

el

US

Bfr

on

t

Op

tica

lD

rive

(To

p)

Op

tica

lD

rive

(Bo

tto

m)

HD

D1

HD

D3

HD

D2

HD

D4

T26139-Y3942-V221

UF

M

Fro

nt

----

-B

ackup

AU

X

64

2

53

1

P1

P9

P8

P4

P3

P6

P7

P2

no

tu

se

d

T2

61

39

-Y3

70

1-V

14

7

T2

61

39

-Y3

89

4-V

51

3

US

BD

AT

/RD

XD

rive

(Bo

tto

m)

T2

61

39

-Y3

94

2-V

1

alte

rna

tive

Page 64: PRIMERGY TX100 S2 Server - Fujitsumanuals.ts.fujitsu.com/file/9432/tx100s2-og-en.pdf · TX100 S2 Options Guide Before reading this manual ... – "D2779 BIOS Setup Utility for PRIMERGY

64 Options Guide TX100 S2

Cabling Appendix

Figure 39: SAS controller with up to 4 SAS HDDs

Po

we

r

SA

S

FD

D

Da

ta

Le

ge

nd

:

US

B

I2C

SA

TA

Pa

ralle

l/S

eri

ell

Ad

ap

ter

Intr

usio

n

Fro

ntfa

n

Fro

ntp

an

el

US

Bfr

on

t

Op

tica

lD

rive

(To

p)

Op

tica

lD

rive

(Bo

tto

m)

HD

D1

HD

D3

HD

D2

HD

D4

UF

M

Fro

nt

----

-B

ackup

AU

X

64

2

53

1

P1

P9

P8

P4

P3

T2

61

39

-Y3

70

1-V

14

7

T2

61

39

-Y3

89

4-V

51

3S

AS

Co

ntr

olle

r

T2

61

39

-Y3

96

4-V

10

1

Page 65: PRIMERGY TX100 S2 Server - Fujitsumanuals.ts.fujitsu.com/file/9432/tx100s2-og-en.pdf · TX100 S2 Options Guide Before reading this manual ... – "D2779 BIOS Setup Utility for PRIMERGY

TX100 S2 Options Guide 65

IndexAaccessible drives 11

equipping bays 33removing dummy cover 33

air ductinstalling 55removing 27

appendix 59

Ccabling 59cabling plan 59components, hardware/software 9configuration of main memory 29

Ddata manipulation 9drive cage

closing 56lifting up 25

Eelectrostatic-sensitive devices

(ESD) 21ENERGY STAR 9equipping bays

accessible drives 33equipping rules

main memory 29expansion card 11

installing 45

Hhard disk drive, HDD 37

Iinformation, additional 11

Llaser information 20light emitting diode (LED) 20lithium battery 18

Mmain memory 11

configuration 29equipping rules 29upgrading 29

meaning of the symbols 12

Nnotational conventions 12

Pparallel interface 11

installing 47PCIe Gen2 slot 11

Rremoving dummy cover 33

Ssecurity function 9server

closing 56opening 23

side coverinstalling 57removing 23

slot, expansion card 11

Ttarget group 9TPM 12, 50Trusted Platform Module 12

UUFM 12, 53USB Flash Module 12

Page 66: PRIMERGY TX100 S2 Server - Fujitsumanuals.ts.fujitsu.com/file/9432/tx100s2-og-en.pdf · TX100 S2 Options Guide Before reading this manual ... – "D2779 BIOS Setup Utility for PRIMERGY

66 Options Guide TX100 S2

Index