2
INSTALLATION INSTRUCTIONS INS 466 STANDARDS Alarm Systems: EN50131-2-2, EN50131-5-3, EN50131-1, PD6662, Grade 2 Class II EMC: EN50130-4:1995: A1: A2 ETSI EN301 489-03 V1.4.1 R&TTE: ETSI EN300-220 (V2.1.1) Environmental: EN50130-5 Frequency Band: 868.0 MHz - 868.6 MHz Prestige and the wireless logo are trade marks of Texecom Ltd. © 2010 The Prestige XT-W/QD-W is protected by European Registered Design. No: 3004997 A20100211 INS466 WARRANTY 2 year replacement warranty (excludes battery). The Prestige XT-W/QD-W is designed to detect the movement of an intruder and activate an alarm control panel. As the Prestige XT-W/QD-W is not a complete alarm system, but only a part thereof, Texecom cannot accept responsibility or liability for any damages whatsoever based on a claim that the Prestige XT-W/QD-W failed to function correctly. Due to our policy of continuous improvement Texecom reserves the right to change specification without prior notice. All specifications are measured at 20ºC (68ºF). Certificate Number: FM 35285 Made In England ALTERING COVERAGE AT 2m MOUNTING HEIGHT 8m 26'2" 10m 32'9" 15m 50' 15m 50' 2m 6'7" 2m 6'7" 2m 6'7" 2m 6'7" Metal Lintel CHOOSING A LOCATION Do not install close to large metal objects or mains wiring 230V 110V >1m >1m Metal Filing Cabinet >1m Avoid common false alarm sources MOUNTING For indoor use only Mount on a stable surface Volumetric Top View COVERAGE & PICK-UP BATTERY SAFETY Do not throw into a fire Do not heat Do not short circuit Do not charge Replace only with same or equivalent type Do not disassemble Always observe local regulations when disposing of a battery Detector will transmit low battery warning when battery needs replacing MOUNTING HEIGHT & SETTINGS 3.0m/9102.5m/822.0m/671.5m/4114m 13'1" 15m 50' 2m 6'7" 2m 6'7" ANGLING THE DETECTOR INTRODUCTION For wireless connectivity, detailed programming and system set-up instructions please refer to the compatible RICOCHETtechnology enabled Premier wireless expander instructions. Featuring RICOCHET wireless technology the Prestige XT-W and Prestige QD-W are designed for professional security installations. Metres Metres Metres 12m 12m 15m Side View

Prestige Xt-w Installation Instructions

Embed Size (px)

DESCRIPTION

Prestige Instalation InstructionThis it meens you have here alll the instruction require for install this.

Citation preview

Page 1: Prestige Xt-w Installation Instructions

INSTALLATION INSTRUCTIONS

INS

466

STANDARDS

Alarm Systems:EN50131-2-2, EN50131-5-3, EN50131-1, PD6662, Grade 2 Class II

EMC:EN50130-4:1995: A1: A2ETSI EN301 489-03 V1.4.1

R&TTE: ETSI EN300-220 (V2.1.1)Environmental: EN50130-5Frequency Band: 868.0 MHz - 868.6 MHz

Prestige and the wireless logo are trade marks of Texecom Ltd. © 2010The Prestige XT-W/QD-W is protected by European Registered Design. No: 3004997A20100211 INS466

WARRANTY2 year replacement warranty (excludes battery).

The Prestige XT-W/QD-W is designed to detect the movement of an

intruder and activate an alarm control panel. As the Prestige XT-W/QD-W

is not a complete alarm system, but only a part thereof, Texecom cannot

accept responsibility or liability for any damages whatsoever based on a

claim that the Prestige XT-W/QD-W failed to function correctly.

Due to our policy of continuous improvement Texecom reserves

the right to change specification without prior notice. All specifications

are measured at 20ºC (68ºF).

Cer tificate Number: FM 35285

Made In England

ALTERING COVERAGE AT 2m MOUNTING HEIGHT

8m26'2"

10m32'9"

15m50'

15m50'

2m6'7"

2m6'7"

2m6'7"

2m6'7"

Metal Lintel

CHOOSING A LOCATIONDo not install close to large metal objects or mains wiring

230V110V

>1m

>1m

Metal Filing Cabinet

>1m

Avoid common false alarm sources MOUNTING For indoor use only

✓✗

✓✗ ✓

Mount on a stable surface

VolumetricTop View

COVERAGE & PICK-UP

BATTERY SAFETY•Do not throw into a fire •Do not heat•Do not short circuit •Do not charge•Replace only with same or equivalent type • Do not disassemble•Always observe local regulations when disposing of a battery•Detector will transmit low battery warning when battery needs replacing

MOUNTING HEIGHT & SETTINGS

3.0m/9’10”

2.5m/8’2”

2.0m/6’7”

1.5m/4’11”

4m13'1"

15m50'

2m6'7" 2m

6'7"

ANGLING THE DETECTOR

INTRODUCTIONFor wireless connectivity, detailed programming •and system set-up instructions please refer to the compatible RICOCHET™ technology enabled Premier wireless expander instructions.

Featuring RICOCHET• ™ wireless technology the Prestige XT-W and Prestige QD-W are designed for professional security installations.

Metres

Me

tre

s

Me

tres

12m 12m

15m

Side View

Page 2: Prestige Xt-w Installation Instructions

HOW TO REMOVE THE CHASSIS Remove chassis before mounting the detector

6

7

5

WALL MOUNT BRACKET*

CEILING MOUNT BRACKET*

31 2

1 2 3 4

4

Note:For EN 50131 compliance both the detector and the rear tamper insert must be fixed to the wall, mounting brackets should not be used.

*Available Separately

DETECTOR KNOCKOUTS

Rear Tamper Insert

60mm(2.4”)

40mm(1.6”)

112.25mm(4.4”)

-35°C (-31°F) to +60°C (+140°F)

160g (5.5oz) approx.

-35°C (-31°F) to +55°C (+131°F)

JP1

JP1

JP1

1

2

Battery TagRemove on installation.

Learn Switch Hold down during battery connection to learn device.

0.3 - 3.0m/s1 - 10ft/s

XT PULSE COUNT

3

QD PULSE COUNT

JP1

JP1

JP1Mounting Height Settings

1

2

3

0.3 - 3.0m/s1 - 10ft/s

LED Indication only available in walktest mode.(See Premier wireless expander instructions)