Water Cooled Screw Chiller Approx-300Tr AC-2 Nox150Tr Advantages and suitability. Electrical Consumption : 0.85 KW / TR / (1.2) Can run upto minimum 10% Capacity Life 25-30 years / 10-15yrs Balancing Valve thermostat in rooms No derating Cost higher Plant Room 1000Sqft HVAC

Presentation General Electrical

Embed Size (px)

DESCRIPTION

i

Citation preview

  • Water Cooled Screw ChillerApprox-300Tr AC-2 Nox150Tr

    Advantages and suitability.Electrical Consumption : 0.85 KW / TR / (1.2)Can run upto minimum 10% Capacity Life 25-30 years / 10-15yrsBalancing Valve thermostat in roomsNo deratingCost higherPlant Room 1000SqftHVAC

  • AIRCONDITIONINGVENTILATIONCONTROLACCESS CONTROLPUBLIC ADDRESSSYSTEMCCTV SURVELILLANCEWATER RESOURCE MANAGEMENTLIGHTING CONTROLLIFTSMONITORINGENERGY MANAGEMENTS/STNDG SETSFIRE AND LIFE SAFETY

    IBMS

    BOARD ROOMCONFERENCEHALL MANAGEMENTCAPABILITIES

  • MANAGE BUILDING PROCESSES EFFICIENTLYREDUCE ENERGY AND OPERATING COSTSPROTECT ASSETS FROM THEFT AND VANDALISMPROVIDE LIFE SAFETY MEASURESIMPROVE PRODUCTIVITY

    BENEFITS

  • Power Distribution System11KV/.433 HT Substation shall be mandatory for this project as total connected load shall exceed 100KW in Torrent Powers Jurisdiction.Four Room Substation may be required by Torrent Power as per its current practice.Substation should be accessible for Torrent Power for O & M point of view.

  • Power Distribution SystemOn each floor, Electrical Rooms for floor wise power distribution shall be required.Main LT Panel shall be provided at Ground Floor and other Floor Panels shall be housed near Load Centre.Capacitor Panel near Main LT Panel or on each Floor near Load Centre.Service Ducts at suitable locations for Power, Voice, Data and Signal Cables shall be provided.Lightening Protection System.Earthing Pits as required for Medium Voltage and Low Voltage Systems.

  • Emergency / Backup Power Distribution SystemIt is proposed to provide silent DG Set for the selected load.Control Panels shall be provided accordingly for floor wise power distribution.Separate power for Comfort AC Load shall also be planned accordingly.Lighting and Power Distribution Boards can be localized.

  • Emergency / Backup Power Distribution SystemIt is proposed to provide UPS backed up by DG set for the supercritical and critical load. UPS Power Distribution Boards shall be provided accordingly for floor wise power distribution.Emergency Lighting, Computer Network, Server Room, Security Systems, Telecommunication System, Building Management System ( BMS ) etc. shall be backed up by UPS and shall be configured accordingly.

  • Electronic Security and Telecommunication SystemsIntegrated Building Management System ( IBMS ).Analog Addressable Fire Detection and Alarm System.Access Control System.CCTV System.Biometric Access Control System for some specific areas such as Server Room, Record Room , High Security Zone etc.Gas Suppression System for Server Room as required.Digital EPABX System

  • Audio-Video SystemsConference Room Audio-Conferencing SystemHigh Resolution Video Projectors in Conference and Meeting RoomsMultipoint Video Conferencing System in Conference RoomPublic Address and Background Music System Separate Music System for Cafeteria.LCD Screens and Touch Screens as required in Reception Area and Foyer Area.High Resolution DLP Video Projectors for Court Room / Auditorium and Seminar Room for presentation etc.

  • LightingHarnessing daylight as far as possible.Lighting Levels as per the Green Building Norms / Requirements.Use of Occupancy Detectors. Sensor based Interior and Exterior Lighting.Area Lighting and Pathway Lighting.Building Flood Lighting and Landscape Lighting.Use of LEDs in circulation and movement areas to the extent possible.Special Digital Lighting Systems for Conference Rooms / Seminar Room / Court Room.Special Dimmable Stage Lighting System for Auditorium.

  • Computer Networking and IT InstallationsProvision of a Server Room.Provision for N+1 Nodes for Desktops and Laptops. Provision for Computer Nodes in the Conference Room / Seminar Room and Court Room.Voice and Data Connectivity using CAT-6 Cables if agreed by GERC IT Managers.Provision for Printers, Copier Machines, Plotters, Scanners etc. individually as in a common Business Room as desired by GERC Authority.