PresentationRM22 multifunction Zelio control relays monitor the following functions on 3-phase supplies:Functions RM22TA RM22TU RM22TR RM22TG
Sequence of phases L1, L2, and L3Phase failure with regenerationAsymmetryUndervoltageOvervoltage and undervoltage
Function performedFunction not performed
Depending on the model RM22T control relays: b Accept different nominal 3-phase voltages: up to 480 V ab Monitor their own power supply measured as a true rms valueb Are designed for clip-on mounting on DIN rail
They feature:b Sealable cover to protect the settingsb Diagnostic button for load circuit testingb Relay output status LEDb Fault detection indication LED b Dial pointer LED indicator for relay power ON statusb Relay output On-delay or Off-delay
Applicationsb Control for connection of moving equipment (site equipment, agricultural equipment, refrigerated trucks)b Control for protection of persons and equipment against the consequences of reverse running (lifting, handling, elevators, escalators, etc.)b Control of sensitive 3-phase suppliesb Protection against the risk of a driving load (phase failure)b Normal/emergency power supply switching
DescriptionRM22TA, RM22TU, RM22TR, RM22TG
1a Voltage range selector switch1b Voltage range/On-Off delay selector2 Time delay adjustment potentiometer Tt3a Asymmetry threshold setting potentiometer Asym3b Undervoltage setting potentiometer <U3c Overvoltage setting potentiometer >U4 Diagnostic button
Operating principleMultifunction 3-phase supply control relays monitor:
b Own power supply b Correct sequencing of phases L1, L2, and L3 b Fault signaling by LED b Phase failure, including in the case of voltage regeneration b Undervoltage from - 2…- 20 % of the supply voltage Un b Overvoltage from 2…20 % of the supply voltage Un b Asymmetry from 5…15 % of the supply voltage Un
Voltage switch operation: v Set the switch to 3-phase supply voltage Un. v The position of this switch is taken into account on energization of the device. v If the switch position is changed while the device is operating, all the LEDs flash
but the product continues to operate normally with the voltage selected at the time of energization preceding the change of position.
v If the switch is returned to the original position selected prior to the last energization, the LEDs return to their normal state.
Presentation, description and operation
Zelio Control - Monitoring and control relaysMultifunction 3-phase control relays RM22TA, RM22TU, RM22TR, and RM22TG
RM22T
L1 L2
12 11 14
22 21 24
R
RM22TA31
DIAGNOSTIC
Def
200208
220
240
8
5
10 12
15%
Asym
L3
Tt
0,1 30s
5
10 20
25
1a23a
4
RM22TA
L1 L2 L3
12 11 14
22 21 24
R
RM22TU23
DIAGNOSTIC
Def
380400 415
440
480
-2
-4-6
-8 -14-16-18
-20%
<U
1a3b
4
RM22TU
L1 L2 L3
12 11 14
22 21 24
R
RM22TG20
DIAGNOSTIC
Un
4
RM22TG
L1 L2 L3
12 11 14
22 21 24
2
46
8 1416 18
20%
R
>U
RM22TR31
DIAGNOSTIC
-2
-4-6
-8 -14-16 -18
-20%
<U
Def
240220
208200
240220
208200
Tt
ON
DEL
AY
OFF
DEL
AY
0,1 30s
5
10 20
25
1b
3c3b4
RM22TR
Un Green LED: indicates that supply to the relay is onR Yellow LED: indicates relay output stateDEF Yellow LED: indicates fault detection
2
1
3
4
5
6
7
8
9
10
2
1
3
4
5
6
7
8
9
10
28614-ENversion: 2.0
2.0
3
Operation (continued)
Operating principle (continued)RM22TAPhase + Asymmetry v Sequence of phases L1, L2, L3 v Phase failure v Asymmetry Asym
L2
L3
0 %
Tt TtR/R1/R2
Phase L3
Phase L2
Phase L1
HysteresisAsymmetry
Relay Outputs
The relay monitors its own supply voltage Un: v correct sequence of three phases v failure of at least one of the three phases (U measured < 0.7 x Un) v asymmetry adjustable from 5…15 % of Un b If a sequencing or phase failure fault is detected, the relay opens
instantly. b If an asymmetry fault is detected, the relay opens at the end of the time
delay set by the user. b On energization of the device with a detected measured fault, the relay
stays open.
Note: Tt: time delay after crossing of threshold (adjustable on front panel)
RM22TUPhase + Undervoltage
v Sequence of phases L1, L2, L3v Phase failure
30 % Un 30 % Un30 % Un
L3
L2
R/R1/R2
Phase L3
Phase L2
Phase L1
Relay Outputs
The relay monitors its own supply voltage Un: v correct sequence of the three phases v failure of at least one of the three phases (U measured < 0.7 x Un) v undervoltage adjustable from - 2…- 20 % of Un b If a sequencing or phase failure fault is detected, the relay opens
instantly. b If a voltage fault is detected, the relay opens instantly. b On energization of the device with a detected measured fault, the relay
stays open.
Note: Tt: time delay after crossing of threshold
v Undervoltage control <U
R/R1/R2
L1/L2/L3
L1L2L3
L2L3
L1
Tt Tt
<UThresholdHysteresis
Relays Output
Phases
Zelio Control - Monitoring and control relaysMultifunction 3-phase control relaysRM22TA, RM22TU, RM22TR, and RM22TG
2
1
3
4
5
6
7
8
9
10
2
1
3
4
5
6
7
8
9
10
28614-ENversion: 2.0
4
Operation (continued) Zelio Control - Monitoring and control relaysMultifunction 3-phase control relaysRM22TA, RM22TU, RM22TR, and RM22TG
Operating principle (continued)RM22TRPhase + Undervoltage/overvoltage
v Phase failure30 % Un 30 % Un30 % Un
R/R1/R2
Phase L3
Phase L2
Phase L1
Relay Outputs
The relay monitors its own supply voltage Un: v phase failure v undervoltage and overvoltage b An adjustable time delay, on crossing the thresholds, provides immunity
to transients, and prevents spurious triggering of the output relay. b If a voltage fault is detected, the relay opens at the end of the time delay
set On-delay or Off-delay by the user. b On energization of the device with a detected measured fault, the relay
stays open. b In the event of phase failure, the relay opens instantly.
Note: Tt: time delay after crossing of threshold (adjustable on front panel)
v Overvoltage and undervoltage (Off-delay)
<U
>UL1L2
L3
Tt TtR/R1/R2
Phases L1/L2/L3
RelayOutputs
Hysteresis
Hysteresis
RM22TGPhase control v Sequence of phases L1, L2, L3 v Phase failure
100 %
0 %
100 %
0 %
100 %
0 %
Tr Tr Tr Tr
L3
L2
R/R1/R2
Phase L1
Phase L2
Phase L3
RelayOutputs
The RM22TG relay monitors: v correct sequencing of the three phases v total loss of one or more of the phases b When phase sequence and voltages are correct (> 183 V a), the output
relays are closed and the yellow LED is on. b When there is a sequencing fault or total loss of one or more phases
(detected as soon as one of the voltages drops below 100 V) the relay opens instantly and the LED goes off.
b On energization of the device with a detected measured fault, the relay stays open.
Note: Tr: response time on appearance of a fault
2
1
3
4
5
6
7
8
9
10
2
1
3
4
5
6
7
8
9
10
28614-ENversion: 2.0
5
References
ReferencesFunction Rated
3-phase supply voltage
Measurement range
Time delay Output Reference Weight
V V kg/lbb Phase
sequenceb Phase failureb Asymmetry
200…240 a 200…240 a Off delay (0.1...30 s)
2 C/O 8 A
RM22TA31 0.090/ 0.198
380…480 a 380…480 a Off delay (0.1...30 s)
2 C/O 8 A
RM22TA33 0.090/ 0.198
b Phase sequence
b Phase failureb Undervoltage
and overvoltage
200…240 a 200…240 a On/Off delay (0.1...30 s)
2 C/O 8 A
RM22TR31 0.090/ 0.198
380…480 a 380…480 a On/Off delay (0.1...30 s)
2 C/O 8 A
RM22TR33 0.090/ 0.198
b Phase sequence
b Phase failureb Undervoltage
200…240 a 200…240 a No 2 C/O 8 A
RM22TU21 0.090/ 0.198
380…480 a 380…480 a No 2 C/O 8 A
RM22TU23 0.090/ 0.198
b Phase sequence
b Phase failure
208…480 a 183…528 a No 2 C/O 8 A
RM22TG20 0.090/ 0.198
Zelio Control - Monitoring and control relaysMultifunction 3-phase control relaysRM22TA, RM22TU, RM22TR, and RM22TG
RM22TG20
RM22TA31 RM22TR31
RM22TU21
PF1
4340
0P
F143
402
PF1
4340
3P
F143
405
2
1
3
4
5
6
7
8
9
10
2
1
3
4
5
6
7
8
9
10
28614-ENversion: 2.0
2
PresentationRM22UA and RM22UB 1-phase or DC voltage control relays monitor the following functions:Functions RM22 UA2MR UA3MR UA33MT UB34
Overvoltage (without memory)Undervoltage (with/without memory)Overvoltage (with/without memory)Overvoltage or undervoltage (windows mode)
Function performedFunction not performed
RM22 control relays enable: b Automatic AC or DC recognitionb Selection between overvoltage and undervoltageb Monitoring their own supply voltage measured as true rms valueb Selectable memory function
They feature:b Dial pointer LED indicator for relay power ON statusb Relay output status LED
The settings are protected by a sealable cover and the control status is indicated by an LED. The relays are designed for clip-on mounting on a DIN rail.
Applicationsb Protection of electronic or electromechanical devices against overvoltage and undervoltageb Normal/emergency power supply switchingb DC motor overspeed controlb Monitoring of AC or DC suppliesb Battery and speed monitoring (with tacho-generator) DescriptionRM22UA2MR, RM22UA3MR, RM22UA33MT, RM22UB34
1 Configuration: selection of operating mode <U (undervoltage), >U (overvoltage), >U> (overvoltage and undervoltage), MEMORY - NO MEMORY (with or without memory)
2a Voltage threshold setting potentiometer U value2b Undervoltage setting potentiometer <U2c Overvoltage setting potentiometer >U3 Time delay adjustment potentiometer Tt4a Hysteresis adjustment potentiometer Hys4b Hysteresis/overvoltage and undervoltage window mode adjustment
potentiometer Hys/>U>5 Diagnostic button6 Configuration: selection of On-delay or Off-delay
Presentation, description
Zelio Control - Monitoring and control relays1-phase or DC voltage control relays RM22UA and RM22UB
RM22UA31MRRM22UA21MR
A1 A2 M
12 11 14
22 21 24
R
Hys
RM22UA23MR
DIAGNOSTIC
E1 E2 E3
>UValue
5
1015
20 3540 45
50%
10
2030
40 7080 90
100% 2c4a
5
RM22UA2pMR
A1 A2 M
12 11 14
E1 E2 E3
22 21 24
U
>
MEM
OR
Y
NO
>
MEM
OR
Y
R
UValue
Hys/>U>
Tt
U >
>
> U
RM22UA31MR
U< U>
< U
DIAGNOSTIC
5
1015
20 3540 45
50%
10
2030
40 7080 90
100%
0,1 30s
5
10 20
25
12a4b35
RM22UA3pMR
A1+ A2-
12 11 14
22 21 24
ON
OFF
DEL
AY
100120140
160 220240260
300V
R
>U
<U
Tt
RM22UB34
DIAGNOSTIC
80280
0,1 30s
5
10 20
25
DEL
AY
100120140
160 220240260
300V80280 2b
2c6
35
RM22U34
A1 A2 M
12 11 14
E1 E2 E3
22 21 24
R
RM22UA33MT
DIAGNOSTIC
U
>
MEM
OR
Y
NO
>
MEM
OR
Y
10
2030
40 708090
100%
5
1015
20 354045
50%
UValue
Hys/>U>
Tt
U >
>
> U
U< U> U<
0,1 30s
5
10 20
25
12a4b35
RM22UA33MT
R Yellow LED: indicates relay output state
2
1
3
4
5
6
7
8
9
10
2
1
3
4
5
6
7
8
9
10
28615-ENversion: 2.0
2.0
3
Operation
Operating principle1-phase or DC voltage control relays monitor:
b the voltage of 1-phase and DC supplies b their own supply voltage for the RM22UB model
An adjustable time delay, on crossing the thresholds, provides immunity to transients, and prevents spurious triggering of the output relay.
RM22 UA2MR/UA3MR/UA33MTThe operating mode is fixed by the user:
b Undervoltage with or without memory b Overvoltage with or without memory
The position of the configuration switch and the operating mode is read by the product on energization: b If the configuration switch is set to an unacceptable position, the product detects a fault, the output relay stays open, and the LEDs flash to
indicate the position error. b If the configuration switch position is changed while the device is operating, all the LEDs flash, but the product continues to operate
normally with the function selected at the time of energization before position change. b If the configuration switch is returned to the original position selected prior to the last energization, the LEDs return to their normal state.
The undervoltage or overvoltage threshold value is set by means of a potentiometer graduated as a percentage of the scale value of U to be monitored. The hysteresis is adjusted by means of a potentiometer graduated from 5…50 % of the threshold setting. The hysteresis value must not exceed the limit values of the measuring range.
Overvoltage without memory b Overvoltage control > U, without memory
>U
Tt
UR/R1/R2Relay
Outputs
Hysteresis
Supply Un
Threshold
If the voltage controlled exceeds the threshold setting for a time greater than that set on the front panel (0.1…30 s), the output relay opens and LED R goes off. During the time delay, this LED flashes.As soon as the voltage drops below the value of the threshold setting minus the hysteresis, the relay instantly closes.
Undervoltage without memory b Undervoltage control < U, without memory
U
<U
TtR/R1/R2Relay
Outputs
Hysteresis
Supply Un
Threshold
If the voltage controlled falls below the threshold setting for a time greater than that set on the front panel (0.1…30 s), the output relay opens and LED R goes off. During the time delay, this LED flashes.As soon as the voltage rises above the value of the threshold setting plus thehysteresis, the relay instantly closes.
Zelio Control - Monitoring and control relays1-phase or DC voltage control relays RM22UA and RM22UB
2
1
3
4
5
6
7
8
9
10
2
1
3
4
5
6
7
8
9
10
28615-ENversion: 2.0
4
Operation (continued) Zelio Control - Monitoring and control relays1-phase or DC voltage control relays RM22UA and RM22UB
Operating principle (continued)RM22 UA2MR/ UA3MR/UA33MT (continued)Overvoltage/undervoltage with memory v Overvoltage control > U, with memory
>U
U
TtR/R1/R2Relay
Outputs
Hysteresis
Supply Un
Threshold
If “Memory” mode is selected, the relay opens when crossing of the threshold is detected and then stays in that position. The power must be switched off to reset the product
Tt: time delay after crossing of threshold
v Undervoltage control < U, with memory
U
Tt
<U
R/R1/R2RelayOutputs
Hysteresis
Supply Un
Threshold
RM22 UA3MR/UA33MT/UB34Overvoltage + undervoltage control relay in window mode b Overvoltage and undervoltage control
in window mode <U<
Tt Tt
U
>U
<U
R/R1/R2RelayOuputs
Hysteresis
Supply Un
ThresholdHysteresis
Threshold
These relays operate in window mode where they check that the voltage con-trolled stays between a minimum and a maximum threshold.
b The undervoltage or overvoltage threshold values are set by means of two graduated potentiometers clearly indicating the Un to be monitored. The hysteresis is fixed at 5 % of the threshold setting.
b If the voltage controlled exceeds the high threshold setting or falls below the low threshold setting for a time greater than that set time on the front panel (0.1…30 s), the output relay opens and LED R goes off. During the time delay, this LED flashes.
b As soon as the voltage falls below the high threshold setting value minus the hysteresis, or rises above the low threshold setting value plus the hysteresis, the relay instantly closes.
b On energization of the device with a detected measured fault, the relay stays open.
Tt: time delay after crossing of threshold
2
1
3
4
5
6
7
8
9
10
2
1
3
4
5
6
7
8
9
10
28615-ENversion: 2.0
5
References
ReferencesFunction Rated supply
voltageMeasurement range
Time delay Output Reference Weight
V V kg/lbb Overvoltage
without memory24…240 z 0.05…5 z No 2 C/O 8 A RM22UA21MR 0.110/
0.242
24…240 z 1…100 z No 2 C/O 8 A RM22UA22MR 0.110/ 0.242
24…240 z 15…500 z No 2 C/O 8 A RM22UA23MR 0.110/ 0.242
b Overvoltage and undervoltage with/without memory
b Overvoltage and undervoltage with memory window
24…240 z 0.05…5 z Off delay (0.1...30 s)
2 C/O 8 A RM22UA31MR 0.110/ 0.242
24…240 z 1…100 z Off delay (0.1...30 s)
2 C/O 8 A RM22UA32MR 0.110/ 0.242
24…240 z 15…500 z Off delay (0.1...30 s)
2 C/O 8 A RM22UA33MR 0.110/ 0.242
380…415 a 15…500 a Off delay (0.1...30 s)
2 C/O 8 A RM22UA33MT 0.110/ 0.242
b Overvoltage and undervoltage without memory
110…240 z 80…300 z On/Off delay (0.1...30 s)
2 C/O 8 A RM22UB34 0.090/ 0.198
Zelio Control - Monitoring and control relays1-phase or DC voltage control relays RM22UA and RM22UB
RM22UA33MT
RM22UA23MR RM22UA33MR
RM22UB34
PF1
4340
9P
F143
413
PF1
4341
2P
F143
414
2
1
3
4
5
6
7
8
9
10
2
1
3
4
5
6
7
8
9
10
28615-ENversion: 2.0
2
PresentationRM22JA and RM35JA multifunction current control relays monitor the following functions:
Functions RM22JA21MR RM22JA31MR RM35JA 32MR/32MTOvercurrent (without memory)Overcurrent (with/without memory)Undercurrent (with/without memory)Overcurrent and undercurrent (with/without memory) (window mode)
Function performedFunction not performed
These control relays enable: b Automatic AC or DC recognitionb Selection between overcurrent and undercurrentb Measurement as true rms valueb Selectable memory function
They feature:b Dial pointer LED indicator for relay power ON statusb Relay output status LED
The settings are protected by a sealable cover and the control status is indicated by an LED. The relays are designed for clip-on mounting on DIN rail.
Applicationsb Excitation control of DC machinesb Load state control of motors and generatorsb Control of current drawn by a 3-phase motorb Monitoring of heating or lighting circuitsb Control of pump draining (undercurrent)b Control of overtorque (crushers)b Monitoring of electromagnetic brakes or clutches DescriptionRM22JA21MR, RM22JA31MR, RM35JA32MR, RM35JA32MT
1 Configuration: selection of operating mode <I (undercurrent), >I (overcurrent), >I> (overcurrent and undercurrent), MEMORY - NO MEMORY (with or without memory)
2 Current threshold setting potentiometer I %3a Hysteresis adjustment potentiometer Hys3b Hysteresis/overcurrent and undercurrent window mode adjustment
potentiometer Hys/>I>4 Time delay adjustment potentiometer Tt5 Diagnostic button6 Overcurrent setting potentiometer >I
Presentation, description
Zelio Control - Monitoring and control relaysCurrent control relays RM22JA and RM35JA
RM35JA32MTRM22JA21MR
A1 A2 M
12 11 14
22 21 24
5
1015
20 3540 45
50%
R
Hys
RM22JA21MR
DIAGNOSTIC
10
20
3040 70
80
90
100%
E1 E2 E3
% I I I>
3a6
RM22JA21MR
MEM
OR
Y
NO
MEM
OR
Y
10
2030
40 708090
100%
5
1015
20 354045
50%
0,1 30s
5
10 20
25
A1 A2 M
12 11 14
E1 E2 E3
22 21 24
> >
R
Hys/
Tt
>
>
>
RM22JA31MR
<><
DIAGNOSTIC
% I I I
I I I> >
I I
I
I I
I
I I
I
I I
I
I I
I
I I
I
3b21
45
RM22JA31MR
A1 A2 E3 E2 E1 M
12 11 14 22 21 24
RM35JA32MR
R
DIAGNOSTIC
<
>
> >MEMORY
> >
>
<
Hys/
Tt
100%10
20
30
40 70
80
90
50%5
10
15
20 35
40
45
30s0,1
5
10 20
25
% I I I
I I I> >
I I I
I I I
I I
I
I I
I
I I
I I I
I
YES NO
3b21
45
RM35JA32MR
<
>
> >MEMORY
> >
>
<
Hys/
Tt
100%10
20
30
40 70
80
90
50%5
10
15
20 35
40
45
30s0,1
5
10 20
25
A1 A2 E3 E2 E1 M
12 11 14 22 21 24
RM35JA32MT
R
DIAGNOSTIC
% I I I
I I I> >
I I I
I I I
I I
I
I I
I
I I
I I I
I
YES NO
3b21
45
RM35JA32MT
R Yellow LED: indicates relay output state
2
1
3
4
5
6
7
8
9
10
2
1
3
4
5
6
7
8
9
10
28616-ENversion: 2.0
2.0
3
Operation
Operating principleCurrent control relays monitor the current of 1-phase and DC supplies
An adjustable time delay, on crossing the thresholds, provides immunity totransients, so preventing spurious triggering of the output relay.
RM22JA1MR/RM35JA32MThe operating mode is fixed by the user:
b Undercurrent with or without memory b Overcurrent with or without memory
The position of the configuration switch and the operating mode is read by the product on energization: b If the configuration switch is set to an unacceptable position, the product detects a fault, the output relay stays open and the LEDs flash to
indicate the position error. b If the configuration switch position is changed while the device is operating, all the LEDs flash, but the product continues to operate normally
with the function selected at the time of energization before position change. b If the configuration switch is returned to the original position selected prior to the last energization, the LEDs return to their normal state.
The undercurrent or overcurrent threshold value is set by means of a potentiometer graduated as a percentage of the scale value of I to be monitored. The hysteresis is adjusted by means of a potentiometer graduated from 5…50 % of the threshold setting. The hysteresis value must not exceed the limit values of the measuring range.
Overcurrent without memory
v Overcurrent detection >I , without memory
R/R1/R2
Tt Tt TiTi
I
>I
RelayOutputs
Hysteresis
Supply Un
Threshold
If the current controlled exceeds the threshold setting for a time greater than that set on the front panel (0.1…30 s), the output relay opens and LED R goes off. During the time delay, this LED flashes.As soon as the current drops below the value of the threshold setting minus the hysteresis, the relay instantly closes.
Undercurrent without memory
v Undercurrent detection <I, without memory
R/R1/R2
TiTt Tt Ti
I<I
RelayOutputs
Hysteresis
Supply Un
Threshold
If the current controlled falls below the threshold setting for a time greater than that set on the front panel (0.1…30 s), the output relay opens and LED R goes off. During the time delay, this LED flashes.As soon as the voltage rises above the value of the threshold setting plus the hysteresis, the relay instantly closes.
Note: Tt: time delay after crossing of threshold Ti: starting inhibit time
Ti is not used for this model
Zelio Control - Monitoring and control relaysCurrent control relays RM22JA and RM35JA
2
1
3
4
5
6
7
8
9
10
2
1
3
4
5
6
7
8
9
10
28616-ENversion: 2.0
4
Operation (continued) Zelio Control - Monitoring and control relaysCurrent control relays RM22JA and RM35JA
Operating principle (continued)RM22JA1MR/RM35JA32M (continued)Overcurrent/Undercurrent with memory
v Overcurrent >I, with memory
R/R1/R2
Ti Tt Ti
I>I
TtRelayOutputs
Hysteresis
Supply Un
Threshold
v Undercurrent <I, with memory
If “Memory” mode is selected, the relay opens when crossing of the threshold is detected and then stays in that position. The power must be switched off to reset the product.
R/R1/R2
Ti Ti
I<I
Tt Tt
RelayOutputs
Hysteresis
Supply Un
Threshold
Note: Tt: time delay after crossing of threshold Ti: starting inhibit time
Ti is not used for this model.
RM22JA1MR/RM35JA32MOvercurrent and undercurrent control in window mode v Overcurrent and undercurrent control in
window mode <I<, without memory
Supply Un
ThresholdHysteresis
HysteresisThreshold
>I
<I
Relay Outputs Tt
<TtU<Tt
TtR/R1/R2
These relays operate in window mode where they check that the current con-trolled stays between a minimum and a maximum threshold.
b The undercurrent or overcurrent threshold values are set by means of two graduated potentiometers clearly indicating the I to be monitored. The hysteresis is fixed at 5 % of the threshold setting.
b If the current controlled exceeds the high threshold setting or falls below the low threshold setting for a time greater than that set time on the front panel (0.1…30 s), the output relay opens and LED R goes off. During the time delay, this LED flashes.
b As soon as the current falls below the high threshold setting value minus the hysteresis, or rises above the low threshold setting value plus the hysteresis, the relay instantly closes.
b On energization of the device with a detected measured fault, the relay stays open.
Note :Tt: time delay after crossing of threshold
2
1
3
4
5
6
7
8
9
10
2
1
3
4
5
6
7
8
9
10
28616-ENversion: 2.0
5
References
ReferencesFunction Rated supply
voltageMeasurement range
Time delay
Output Reference Weight
V mA kg/lbb Overcurrent
without memory24…240 z 4…1000 z No 2 C/O 8 A RM22JA21MR 0.110/
0.242
b Overcurrent with/without memory
b Undercurrent with/without memory
b Overcurrent and undercurrent (windows mode) with/without memory
24…240 z 4…1000 z Off delay (0.1...30 s)
2 C/O 8 A RM22JA31MR 0.110/ 0.242
24…240 z 1500…15000 z Off delay (0.1...30 s)
2 C/O 8 A RM35JA32MR 0.120/ 0.264
380…415 a 1500…15000 a Off delay (0.1...30 s)
2 C/O 8 A RM35JA32MT 0.120/ 0.264
Zelio Control - Monitoring and control relaysCurrent control relays RM22JA and RM35JA
RM35JA32MR
RM22JA21MR RM22JA31MR
RM35JA32MT
PF1
4341
5
PF1
4341
6P
F143
418
PF1
4341
7
2
1
3
4
5
6
7
8
9
10
2
1
3
4
5
6
7
8
9
10
28616-ENversion: 2.0
PresentationRM22LA and RM22LG liquid level control relays control one or two liquid levels, with a fill or empty function: Functions RM22LA 32MR/32MT RM22LG 11MR/11MT
Level 1/Level 2Fill operationEmpty operationLow sensitivityStandard sensitivityHigh sensitivity
Function performedFunction not performed
RM22 liquid level control relays feature:b A dial pointer LED indicator for relay power ON statusb A relay output status LED
The settings are protected by a sealable cover and the control status is indicated by an LED. The relays are designed for clip-on mounting on a DIN rail.
ApplicationsThese devices monitor the levels of conductive liquids.They control the actuation of pumps or valves to regulate levels and are alsosuitable for protecting submersible pumps against dry running, or protecting tanksfrom “overflow”. They can also be used to control dosing of liquids in mixingprocesses and to protect heating elements in the event of non-immersion.They have a transparent, hinged cover on their front panel to avoid any accidentalalteration of the settings. This cover can be directly sealed.
b Application examples for compatible liquids:v spring, town, industrial, and sea waterv metallic salt, acid, or base solutionsv liquid fertilizersv non-concentrated alcohol (< 40 %)v liquids in the food-processing industry: milk, beer, coffee, etc. DescriptionRM22LG11MR, RM22LG11MT, RM22LA32MR, RM22LA32MT
1 Configuration: selection of the operating mode (Fill or Empty) and the sensitivity range (LS/St/HS)
2 Sensitivity control potentiometer (kΩ or %)3 Configuration: selection of the number of levels and theOn/Off time delay4 Time delay control potentiometer Tt5 Diagnostic button
Presentation, description
Zelio Control - Monitoring and control relaysLiquid level control relays RM22LA and RM22LG
RM22LA32MTRM22LG11MR
A1 A2 NC
12 11 14
22 21 24
R
Sens
Level
Tt
RM22LA32MR
DIAGNOSTIC
Min Max C
St. St. HS
LS
LS
HS
1
2
1
2
102030 70
80
100%590
40 60
ON
D
ELAY
OFF
DEL
AY
0,1 30s
5
10 20
25
321
45
RM22LA32MR
A1 A2 NC
12 11 14
102030 70
80
100
R
Sens
Level
RM22LG11MR
DIAGNOSTIC
590
Min Max C
40 60
1 2
KΩ
321
5
RM22LG11MR
A1 A2 NC
12 11 14
22 21 24
RM22LA32MT
DIAGNOSTIC
Min Max C
Sens
Level
Tt
St. St. HS
LS
LS
HS
1
2
1
2
102030 70
80
100%590
40 60
ON
D
ELAY
OFF
DEL
AY
0,1 30s
5
10 20
25
R
321
45
RM22LA32MT
A1 A2 NC
12 11 14
R
Sens
Level
RM22LG11MT
DIAGNOSTIC
Min Max C
102030 70
80
100590
40 60
1 2
KΩ
321
5
RM22LG11MT
R Yellow LED: indicates relay output state
2.0
Operation
Operating principleLiquid level control relays are designed to measure and control the levels of conductive liquids by means of resistive probes.The operating principle is based on measurement of the apparent resistance of the liquid between two submerged probes. When this value is less than the threshold setting on the front panel of the device, the relay changes state. To avoid electrolytic phenomena, an AC current runs across the probes. A selector switch on the front panel allows selection of the required function and the sensitivity range. Control of a single level can be achieved by using the second selector switch. In this case, the Max. level probe stays up in the air and an adjustable time delay avoids any wave effect. Both products activate their output relay when a tank is either emptying or filling.
RM22LA and RM22LGA selector switch on the front panel of these relays allows selection of the required sensitivity range and the empty or fill function. A second switch allows selection of the number of levels (1 or 2) and the type of time delay in the case of level 1 mode. The position of these configu-ration switches is taken into account on energization.b If the configuration switch is set to an unacceptable position, the product detects a fault, the output relay stays open, and the LEDs flash to signal the position error. b If the configuration switch position is changed while the device is operating, all the LEDs flash, but the product continues to operate normally with the function selected at the time of energization preceding the change of position.b If the configuration switch is returned to the original position selected prior to the last energization, the LEDs return to their normal state.
Control of two levels, empty and fill function v Fill/Empty function (2 levels)
R/R1/R2
R/R1/R2
Supply Un
Relay Outputs
Relay Outputs
Max. level
Min. level
b Empty functionlevel: 2, function:
- LS (Low Sensitivity: 250 W…5 kW) - St (Standard Sensitivity: 5 kW…100 kW) - HS (High Sensitivity: 50 kW…1 MW)
The output relay stays open until the liquid reaches the Max. level probe. As soon as the Max. level is reached, the contact closes and then allows emptying of the tank (valve opens, pump starts, ...). When the level drops below the Min. level, the contact opens to stop the emptying process.
b Fill functionlevel: 2, function:
- LS (Low Sensitivity: 250 W…5 kW) - St (Standard Sensitivity: 5 kW…100 kW) - HS (High Sensitivity: 50 kW…1 MW)
The output relay stays energized until the liquid reaches the Max. level probe. As soon as the Max. level is reached, the contact opens and the pump stops. When the level drops below the Min. level, the contact closes again and pumping re-starts to raise the level.
Zelio Control - Monitoring and control relaysLiquid level control relays RM22LA and RM22LG
4
Operation (continued) Zelio Control - Monitoring and control relaysLiquid level control relays RM22LA and RM22LG
Operating principle (continued)RM22LA and RM22LG (continued) Control of one level, empty function v Empty function T on
Tt Tt TtR/R1/R2
Supply Un
Relay Outputs
Level
b level: 1 - on delay functions: - LS (Low Sensitivity: 250 W…5 kW) - St (Standard Sensitivity: 5 kW…100 kW) - HS (High Sensitivity: 50 kW…1 MW)
When the liquid level rises above the probe for a time greater than the time delay value Tt set on the front panel, the relay is energized and stays energized until the liquid level drops back to the probe. If the liquid drops back below the set level before the end of the time delay, the relay does not energize.
v Empty function T off
Tt Tt TtR/R1/R2
Supply Un
Relay Outputs
Level
b level: 1 - off delay functions: - LS (Low Sensitivity: 250 W…5 kW) - St (Standard Sensitivity: 5 kW…100 kW) - HS (High Sensitivity: 50 kW…1 MW)
When the liquid level rises above the probe, the relay instantly energizes and stays energized until the liquid again reaches the probe level for a time Tt set on the front panel. If the liquid drops back below the set level before the end of the time delay period, the relay stays energized.
Control of one level, fill function v Fill function T on
Tt Tt TtR/R1/R2
Supply Un
Relay Outputs
Level
b level: 1 - on delay functions: - LS (Low Sensitivity: 250 W…5 kW) - St (Standard Sensitivity: 5 kW…100 kW) - HS (High Sensitivity: 50 kW…1 MW)
When the liquid level drops below the probe for a time greater than the time delay value Tt set on the front panel, the relay is energized and stays energized until the liquid level rises back up to the probe. If the liquid rises back above the set level before the end of the time delay period, the relay does not energize.
v Fill function T off
Tt Tt TtR/R1/R2
Supply Un
Relay Outputs
Level
b level: 1 - off delay functions: - LS (Low Sensitivity: 250 W…5 kW) - St (Standard Sensitivity: 5 kW…100 kW) - HS (High Sensitivity: 50 kW…1 MW)
When the liquid level drops below the probe, the relay instantly energizes and stays energized until the liquid level again reaches the probe level and stays above it for a time greater than the time delay period Tt set on the front panel. If the liquid drops back below the set level before the end of the time delay period, the relay stays energized.
Note: Tt: time delay after crossing of threshold
2
1
3
4
5
6
7
8
9
10
2
1
3
4
5
6
7
8
9
10
28617-ENversion: 2.0
5
Operation (continued),references
Zelio Control - Monitoring and control relaysLiquid level control relays RM22LA and RM22LG
ReferencesFunction Rated supply
voltageMeasurement range
Time delay
Output Reference Weight
V Ω kg/lbb Level 1/
Level 2b Fill
operationb Empty
operation
24…240 z 5 K…100 K No 1 C/O 8 A RM22LG11MR 0.100/ 0.220
380…415 a 5 K…100 K No 1 C/O 8 A RM22LG11MT 0.100/ 0.220
24…240 z 250...1 M On/Off delay (0.1...30 s)
2 C/O 8 A RM22LA32MR 0.110/ 0.242
380…415 a 250...1 M On/Off delay (0.1...30 s)
2 C/O 8 A RM22LA32MT 0.110/ 0.242
RM22LA32MR
RM22LG11MR RM22LG11MT
RM22LA32MT
PF1
4341
9P
F143
421
PF1
4342
0P
F143
422
2
1
3
4
5
6
7
8
9
10
2
1
3
4
5
6
7
8
9
10
28617-ENversion: 2.0
2
References
ProbesApplication No.
of probes
Length Opera-ting temper-ature
Maximum pressure
Reference Weight
mm °C kg/cm2 kg/lbRecommended for drinks vending machines and where installation space is limited (Stainless steel)
3 1000 80 2 RM79696044 0.800/ 1.764
Suitable for boilers, pressure vessels and under high temperature conditions (1)(304 stainless steel)
1 1000 200 25 RM79696014 0.360/ 0.794
Description Material Reference Weightkg/lb
Protected probe for mounting by suspension
Protective shell PUC (S7) Electrode : stainless steel
RM79696043 0.150/ 0.331
Description Type of installation
Maximum operating temperature
Reference Weight
°C kg/lbLiquid level control probe
Suspended by cable
100 LA9RM201 0.100/0.220
(1) 3/8” BSP mounting thread with hexagonal head. Use a 24 mm spanner for tightening.
RM79696043
5610
34
LA9RM201
Zelio Control – Monitoring & Control RelaysProbes, Electrode holders
4.0
28550-ENversion: 4.0
1
2
3
4
5
6
7
8
9
10
3
Electrode holdersDescription Material Reference Weight
kg/lbElectrode for use up to 350 °C and 15 kg/cm2 (1)
Stainless steel isolated by ceramic
RM79696006 0.150/ 0.331
(1) 3/8” BSP mounting thread.
RM79696006
5610
35
5610
36
Zelio Control – Monitoring & Control RelaysProbes, Electrode holders
References
28550-ENversion: 4.0
1
2
3
4
5
6
7
8
9
10