7
GENERAL SITE INFORMATION: SITE AREA: DENSITY (FSI): BUILDINGS: BUILDING USE: BUILDINGS AREAS: TOTAL FLOOR AREA (TFA) AND ABOVE GRADE GROSS FLOOR AREA (GFA) Site Address: PRELIMINARY PROJECT STATISTICS: Developer: Building Type: Total Area: Total GFA: Residential GFA Non-Residential GFA Total GFA Toronto Zoning Bylaw 569-2013 sq.m. sq.ft. acre ha Floor Level Podium Podium Lower (Typical) Podium Upper (Typical) Tower (Typical) Level 1 (Retail) Level 2 (Retail/Office) Level 3 (Amenity) Level 4 Level 5 Level 6 Level 7 Level 8 Level 9 Level 10 Level 11 Level 12 (Amenity) Level 13 Level 14 Level 15 Level 16 Level 17 Level 18 Level 19 Level 20 Level 21 Level 22 Level 23 Level 24 Level 25 Level 26 Level 27 Level 28 Level 29 Level 30 Level 31 Level 32 Level 33 Level 34 Level 35 Level 36 Level 37 Level 38 Level 39 Level 40 Level 41 Level 42 Level 43 Level 44 Level 45 Level 46 Level 49 (Residential PH) Site Area: 400-420 King Street West Mixed Use Development (Commercial/Residential/Office) FSI: ZBL Established Site Elevation (at grade) Building Height 86.4 m 49+ Mechanical Penthouse 156.9 Storeys Height* *From established grade to Top of Mechanical PH, excluding roofing materials, parapets, and architectural ornamental elements. sq.m. sq.ft. TOTAL TFA COMMERCIAL TFA RESIDENTIAL TFA TOTAL GFA TOTAL GFA UNIT MIX Toronto Zoning Bylaw 569-2013 Toronto Zoning Bylaw 438-86 OCCUPANCY TFA (EXCLUDING BALCONIES & TERRACES) TOTAL COMMERCIAL FLOOR AREA AND PROPOSED OFFICE COMMERCIAL LEASABLE & PROPOSED OFFICE COMMERCIAL EFFICIENCY DEVELOPMENT TOTAL sq.m. sq.ft. sq.m. sq.ft. sq.m. sq.ft. sq.m. sq.ft. sq.m. sq.ft. sq.m. sq.ft. sq.m. sq.ft. sq.m. sq.m. % sq.m. TOTAL RESIDENTIAL FLOOR AREA RESIDENTIAL SALEABLE AREA RESIDENTIAL EFFICIENCY GFA DEDUCTION TOTAL GFA GFA DEDUCTION TOTAL GFA FLOOR LEVEL UNIT TYPE S 1 BR 2 BR 3 BR TOTAL Podium Podium Lower (Typical) Podium Upper (Typical) Tower (Typical) Level 1 (Retail) Level 2 (Retail/Office) Level 3 (Amenity) Level 4 Level 5 Level 6 Level 7 Level 8 Level 9 Level 10 Level 11 Level 12 (Amenity) Level 13 Level 14 Level 15 Level 16 Level 17 Level 18 Level 19 Level 20 Level 21 Level 22 Level 23 Level 24 Level 25 Level 26 Level 27 Level 28 Level 29 Level 30 Level 31 Level 32 Level 33 Level 34 Level 35 Level 36 Level 37 Level 38 Level 39 Level 40 Level 41 Level 42 Level 43 Level 44 Level 45 Level 46 PROPOSED UNIT MIX sq.m. sq.ft. sq.m. sq.ft. sq.m. sq.ft. sq.m. sq.ft. sq.m. sq.ft. AVERAGE UNIT SIZE: (*) Toronto Zoning Bylaw 569-2013 (**) Toronto Zoning Bylaw 438-86 sq.m. sq.ft. sq.m. sq.ft. sq.m. sq.m. AMENITY DEDUCTION (2 sq.m. per Unit) FINAL GFA - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - 2,612 28,112 0.6 0.3 2,612 Toronto Zoning Bylaw 569-2013 Levels Area sq.m. sq.ft. Levels 03 & 12 Total Proposed (Indoor Amenity) Ratio Proposed Indoor Amenity sq.m. sq.ft. Levels 03 & 12 Total Proposed (Outdoor Amenity) Ratio Proposed Outdoor Amenity Type Indoor Amenity Proposed Amenity per Unit Proposed Ratio Outdoor Amenity sq.m. sq.ft. Total Gross Retail Area Total Gross Office Area Location Regular Accessible Total Proposed Resident Parking Spaces P3 P2 P1 Total Type Resident Visitor Total Required Resident Parking Spaces 1 BR 2 BR 3 BR Total Visitor Required Retail Parking Spaces Total Required Parking Spaces Building # of Units Total Number of Units Building Tower (excluding Mechanical Penthouse) 154.0 Height (m) 0.86 Building Heights Average Grade Height (m) Building Studio 1 BR Proposed Unit Mix Tower and Podium Total 2 BR 3 BR Total Use Standard Bicycle Parking Space Calculation for New Building Resident Occupant Bicycle Space Required # of Units Resident Visitor Retail / Office Occupant Retail / Office Visitor Area (sq.m.) Subtotal Subtotal Long-Term Space Required Short-Term Space Required Total Bicycle Parking Spaces Required Total Bicycle Parking Spaces Provided Use Type 'A' City of Toronto Zoning By-Law 569-2013 Loading Standard Residential Total (Residential and Non-residential Sharing) 0 # of Loading 2 Units / GFA Retail & Office Required Number of Loading Spaces Type 'B' Type 'C' Type 'G' 0 0 0 1 1 1 0 1 1 0 1 1 2 General Notes: 1. All areas are approximate. Actual square footage may vary from that stated hereon. 2. Final car parking, bicycle parking and locker count to be confirmed pending structural and mechanical input. 3. All figures are reflective of the current state of schematic and conceptual design and are subject to change. 4. These are preliminary numbers and are not to be relied upon for legal agreements, project valuations, sales, etc. Green Roof Calculation Green Roof Statistics Proposed Gross Floor Area, as defined in Green Roof By-Law (sq.m.) Total Roof Area (sq.m.) Area of Residential Private Terraces (sq.m.) Rooftop Outdoor Amenity Space, if in a Residential Building (sq.m.) Area of Renewable Energy Devices (sq.m.) Tower (s) Roof Area with floor plate less than 750 (sq.m.) Total Available Roof Space (sq.m.) Green Roof Coverage Required Proposed Coverage of Available Roof Space (sq.m.) Coverage of Available Roof Space (%) Deduction in accordance with Toronto Zoning Bylaw 569-2013 which includes Exit stairwells, Mechanical rooms, Elevator shafts, Bicycle Parking and Garbage Chute. Required amenity by this by-law and above grade bicycle parking required by this by-law. Deduction in accordance with Toronto Zoning Bylaw 438-86 which includes Mechanical rooms, Elevator shafts, Bicycle Parking and Garbage Chute (Including Surrounding Walls).Required amenity by this by-law and above grade bicycle parking required by this by-law. (*) Toronto Zoning Bylaw 569-2013 (**) Toronto Zoning Bylaw 438-86 Level 47 Level 48 Level 49 (Residential PH) Level 47 Level 48 43,200 465,004 1,266 13,627 1,266 13,627 43,200 465,004 43,401 467,164 10.3% 44.5% 34.3% 10.9% 100% 605 sq.ft. 54.8% 45.2% 43,200 16.5 - - - - - - - - - - 69 258 243 64 64 69 258 243 634 64 570 173 807 688 49,638 2,082.1 382.8 959.7 N/A N/A 739.6 443.8 60% 450 60% 39,843 428,868 * Above Grade Drawing No.: Drawn by: Scale: Date: Project No.: DATE DESCRIPTION REVISION 3 - Positions of exposed or finished mechanical or electrical devices, fittings, and fixtures are indicated on the Architectural drawings. The locations shown on the Architectural drawings govern over the Mechanical and Electrical drawings. Those items not clearly located will be located as directed by the Architect. 2 - Drawings are not to be scaled for construction. Contractor to verify all existing conditions and dimensions required to perform the Work and report any discrep - ancies with the Contract Documents to the Architect before commencing work. clarification or supplementary information regarding the intent of the Contract Documents. The Architect will review Shop Drawings submitted by the Contractor for design conformance only. C:\Users\alyssa\Documents\400-420 King West_alyssa.rvt 1 : 1 1708 JULY 04, 2019 PM A000a STATISTICS 400-420 KING STREET WEST ## Street City, State Zip 43,200 m2 39,818 m2 2,436 m2 N/A N/A 633 600 570 64 136 0 0 80 296 232 8 189 N/A N/A 64 16 16 1 1 181 104 % 2957.6 57.7 57.7 57.7 57.7 57.7 57.7 57.7 57.7 57.7 57.7 57.7 57.7 57.7 57.7 57.7 57.7 57.7 57.7 57.7 57.7 57.7 57.7 57.7 57.7 57.7 57.7 57.7 57.7 57.7 57.7 57.7 57.7 57.7 57.7 57.7 57.7 57.7 64.5 64.5 64.5 64.5 64.5 57.7 74.8 64.5 64.5 64.5 109.9 65.9 3,167.4 59.0 59.0 59.0 59.0 59.0 59.0 59.0 59.0 59.0 59.0 59.0 59.0 59.0 59.0 59.0 59.0 59.0 59.0 59.0 59.0 59.0 59.0 59.0 59.0 59.0 59.0 59.0 59.0 59.0 59.0 59.0 59.0 59.0 59.0 59.0 59.0 59.0 61.9 61.9 61.9 61.9 61.9 75.9 150.8 66.0 65.6 83.7 128.1 104.7 282 8 8 8 8 8 7 7 7 7 7 7 7 7 7 7 7 7 7 7 7 7 7 7 7 7 7 7 7 7 7 7 7 8 8 8 8 5 6 6 4 65 2 2 2 2 2 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 2 5 5 5 5 1 2 2 2 217 4 4 4 4 4 4 4 4 4 4 4 4 4 4 4 4 4 4 4 4 4 4 4 4 4 4 4 4 4 4 4 4 4 4 4 4 4 6 7 7 7 7 3 10 10 12 69 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 5 5 5 5 5 5 2 4 4 3 633 14 14 14 14 14 13 13 13 13 13 13 13 13 13 13 13 13 13 13 13 13 13 13 13 13 13 13 13 13 13 13 9 9 9 9 9 9 17 20 20 20 20 9 22 22 21 44,466.3 478,631 774.0 8,331 774.0 8,331 774.0 8,331 774.0 8,331 774.0 8,331 774.0 8,331 774.0 8,331 774.0 8,331 774.0 8,331 774.0 8,331 774.0 8,331 774.0 8,331 774.0 8,331 774.0 8,331 774.0 8,331 774.0 8,331 774.0 8,331 774.0 8,331 774.0 8,331 774.0 8,331 774.0 8,331 774.0 8,331 774.0 8,331 774.0 8,331 774.0 8,331 774.0 8,331 774.0 8,331 774.0 8,331 774.0 8,331 774.0 8,331 774.0 8,331 774.0 8,331 774.0 8,331 774.0 8,331 774.0 8,331 774.0 8,331 774.0 8,331 1,111.3 11,962 1,096.6 11,803 1,096.6 11,803 1,096.6 11,803 1,096.6 11,803 738.6 7,950 1,476.2 15,889 1,505.6 16,206 1,473.7 15,863 1,457.5 15,689 1,511.1 16,266 2,167.5 23,331 44,666.9 480,791 775.3 8,345 775.3 8,345 775.3 8,345 775.3 8,345 775.3 8,345 775.3 8,345 775.3 8,345 775.3 8,345 775.3 8,345 775.3 8,345 775.3 8,345 775.3 8,345 775.3 8,345 775.3 8,345 775.3 8,345 775.3 8,345 775.3 8,345 775.3 8,345 775.3 8,345 775.3 8,345 775.3 8,345 775.3 8,345 775.3 8,345 775.3 8,345 775.3 8,345 775.3 8,345 775.3 8,345 775.3 8,345 775.3 8,345 775.3 8,345 775.3 8,345 775.3 8,345 775.3 8,345 775.3 8,345 775.3 8,345 775.3 8,345 775.3 8,345 1,108.7 11,934 1,094.0 11,775 1,094.0 11,775 1,094.0 11,775 1,094.0 11,775 758.3 8,163 1,549.6 16,679 1,507.1 16,223 1,475.0 15,876 1,476.7 15,895 1,525.6 16,422 2,204.9 23,734 3,487 37,534 1,250 13,459 2,237 24,075 44,147 475,191 833 8,967 833 8,967 833 8,967 833 8,967 833 8,967 833 8,967 833 8,967 833 8,967 833 8,967 833 8,967 833 8,967 833 8,967 833 8,967 833 8,967 833 8,967 833 8,967 833 8,967 833 8,967 833 8,967 833 8,967 833 8,967 833 8,967 833 8,967 833 8,967 833 8,967 833 8,967 833 8,967 833 8,967 833 8,967 833 8,967 833 8,967 833 8,967 833 8,967 833 8,967 833 8,967 833 8,967 833 8,967 1,173 12,628 1,158 12,469 1,158 12,469 1,158 12,469 1,158 12,469 814 8,767 1,627 17,512 1,572 16,917 1,539 16,569 1,541 16,589 389 4,185 36 383 47,634 512,725 833 8,967 833 8,967 833 8,967 833 8,967 833 8,967 833 8,967 833 8,967 833 8,967 833 8,967 833 8,967 833 8,967 833 8,967 833 8,967 833 8,967 833 8,967 833 8,967 833 8,967 833 8,967 833 8,967 833 8,967 833 8,967 833 8,967 833 8,967 833 8,967 833 8,967 833 8,967 833 8,967 833 8,967 833 8,967 833 8,967 833 8,967 833 8,967 833 8,967 833 8,967 833 8,967 833 8,967 833 8,967 1,173 12,628 1,158 12,469 1,158 12,469 1,158 12,469 1,158 12,469 814 8,767 1,627 17,512 1,572 16,917 1,539 16,569 1,541 16,589 1,639 17,645 2,272 24,458 130 53 52 25 65 65 282 282 217 217 69 69 2.6 1,665 17,917 1,665 17,917 960 10,330 1.5 930 10,015 2,426 26,118 10931.9 633 633 10931.9 2.6 1.5 3,357 36,132 633 633 633 633 9 3 3 3 121 50 49 22 962 m2 490 N/A N/A 8 1 1 2.8 10.2 8.1 1 ISSUED FOR SUBMISSION JUN. 26/2017 2 ISSUED FOR RE-SUNMISSION MAR.22/2018 3 ISSUED FOR SETTLEMENT OFFER APR. 22/2019 4 RE-ISSUED FOR SETTLEMENT OFFER JUN. 06/2019 5 RE-ISSUED FOR SETTLEMENT OFFER JLY. 04/2019 CC9.24 - CONFFIDENTIAL ATTACHMENT 3 - made public on July 26, 2019

PRELIMINARY PROJECT STATISTICS...GENERAL SITE INFORMATION: SITE AREA: DENSITY (FSI): BUILDINGS: BUILDING USE: BUILDINGS AREAS: TOTAL FLOOR AREA (TFA) AND ABOVE GRADE GROSS FLOOR AREA

  • Upload
    others

  • View
    4

  • Download
    0

Embed Size (px)

Citation preview

Page 1: PRELIMINARY PROJECT STATISTICS...GENERAL SITE INFORMATION: SITE AREA: DENSITY (FSI): BUILDINGS: BUILDING USE: BUILDINGS AREAS: TOTAL FLOOR AREA (TFA) AND ABOVE GRADE GROSS FLOOR AREA

GENERAL SITE INFORMATION:

SITE AREA:

DENSITY (FSI):

BUILDINGS:

BUILDING USE:

BUILDINGS AREAS: TOTAL FLOOR AREA (TFA) AND ABOVE GRADE GROSS FLOOR AREA (GFA)

Site Address:

PRELIMINARY PROJECT STATISTICS:

Developer:

Building Type:

Total Area:

Total GFA:

Residential GFA

Non-Residential GFA

Total GFA

Toronto Zoning Bylaw 569-2013

sq.m. sq.ft. acre ha

Floor Level

Podium

Podium Lower (Typical)

Podium Upper (Typical)

Tower (Typical)

Level 1 (Retail)

Level 2 (Retail/Office)

Level 3 (Amenity)

Level 4

Level 5

Level 6

Level 7

Level 8

Level 9

Level 10

Level 11

Level 12 (Amenity)

Level 13

Level 14

Level 15

Level 16

Level 17

Level 18

Level 19

Level 20

Level 21

Level 22

Level 23

Level 24

Level 25

Level 26

Level 27

Level 28

Level 29

Level 30

Level 31

Level 32

Level 33

Level 34

Level 35

Level 36

Level 37

Level 38

Level 39

Level 40

Level 41

Level 42

Level 43

Level 44

Level 45

Level 46

Level 49 (Residential PH)

Site Area:

400-420 King Street West

Mixed Use Development (Commercial/Residential/Office)

FSI:

ZBL Established Site Elevation (at grade)

Building Height

86.4 m

49+ Mechanical Penthouse 156.9

Storeys Height*

*From established grade to Top of Mechanical PH, excluding roofing materials, parapets, and architectural ornamental elements.

sq.m. sq.ft.

TOTAL TFA COMMERCIAL TFA RESIDENTIAL TFA TOTAL GFA TOTAL GFA UNIT MIX

Toronto Zoning Bylaw 569-2013 Toronto Zoning Bylaw 438-86

OCCUPANCYTFA (EXCLUDING

BALCONIES &

TERRACES)

TOTAL COMMERCIAL

FLOOR AREA AND

PROPOSED OFFICE

COMMERCIAL

LEASABLE & PROPOSED

OFFICE

COMMERCIAL

EFFICIENCY

DEVELOPMENT TOTAL

sq.m. sq.ft. sq.m. sq.ft. sq.m. sq.ft. sq.m. sq.ft. sq.m. sq.ft. sq.m. sq.ft. sq.m. sq.ft.sq.m. sq.m.% sq.m.

TOTAL RESIDENTIAL

FLOOR AREARESIDENTIAL SALEABLE AREA

RESIDENTIAL

EFFICIENCY

GFA

DEDUCTIONTOTAL GFA

GFA

DEDUCTIONTOTAL GFA

FLOOR LEVELUNIT TYPE

S 1 BR 2 BR 3 BR TOTAL

Podium

Podium Lower (Typical)

Podium Upper (Typical)

Tower (Typical)

Level 1 (Retail)

Level 2 (Retail/Office)

Level 3 (Amenity)

Level 4

Level 5

Level 6

Level 7

Level 8

Level 9

Level 10

Level 11

Level 12 (Amenity)

Level 13

Level 14

Level 15

Level 16

Level 17

Level 18

Level 19

Level 20

Level 21

Level 22

Level 23

Level 24

Level 25

Level 26

Level 27

Level 28

Level 29

Level 30

Level 31

Level 32

Level 33

Level 34

Level 35

Level 36

Level 37

Level 38

Level 39

Level 40

Level 41

Level 42

Level 43

Level 44

Level 45

Level 46

PROPOSED UNIT MIXsq.m. sq.ft. sq.m. sq.ft. sq.m. sq.ft. sq.m. sq.ft. sq.m. sq.ft.

AVERAGE UNIT SIZE:

(*) Toronto Zoning Bylaw 569-2013 (**) Toronto Zoning Bylaw 438-86

sq.m. sq.ft. sq.m. sq.ft.sq.m. sq.m.

AMENITY DEDUCTION

(2 sq.m. per Unit)

FINAL GFA

-

-

-

-

-

-

-

-

-

-

-

-

-

-

-

-

- -

- - - - -- - - - -

- - - - -

- - - - -

- - - - -

- - - - -

- - - - -

- - - - -

- - - - -

- - - - -

- - - - -

- - - - -

- - - - -

- - - - -

- - - - -

- - - - -

- - - - -

- - - - -

- - - - -

- - - - -

- - - - -

- - - - -

- - - - -

- - - - -

- - - - -

- - - - -

- - - - -

- - - - -

- - - - -

- - - - -

- - - - -

- - - - -

- - - - -

- - - - -

- - - - -

- - - - -

- - - - -

- - - - -

- - - - -

- - - - -

- - - - -

- - - - -

- - - - -

- - - - -

- - - - -

- - - - -

- -

- -

- -

2,612 28,112 0.6 0.3

2,612

Toronto Zoning Bylaw 569-2013

LevelsArea

sq.m. sq.ft.

Levels 03 & 12

Total Proposed (Indoor Amenity)

Ratio

Proposed Indoor Amenity

sq.m. sq.ft.Levels 03 & 12

Total Proposed (Outdoor Amenity)

Ratio

Proposed Outdoor Amenity

Type

Indoor Amenity

Proposed Amenity per Unit

Proposed Ratio

Outdoor Amenity

sq.m. sq.ft.

Total Gross Retail Area

Total Gross Office Area

Location Regular Accessible Total

Proposed Resident Parking Spaces

P3

P2

P1

Total

Type Resident Visitor Total

Required Resident Parking Spaces

1 BR

2 BR

3 BR

Total

Visitor

Required Retail Parking Spaces

Total Required Parking Spaces

Building # of Units

Total

Number of UnitsBuilding

Tower (excluding Mechanical Penthouse) 154.0

Height (m)

0.86

Building Heights

Average Grade Height (m)

Building Studio 1 BR

Proposed Unit Mix

Tower and Podium

Total

2 BR 3 BR Total

Use Standard

Bicycle Parking Space Calculation for New Building

Resident Occupant

Bicycle Space Required# of Units

Resident Visitor

Retail / Office Occupant

Retail / Office Visitor

Area (sq.m.) Subtotal

Subtotal

Long-Term Space Required

Short-Term Space Required

Total Bicycle Parking Spaces Required

Total Bicycle Parking Spaces Provided

UseType 'A'

City of Toronto Zoning By-Law 569-2013 Loading Standard

Residential

Total (Residential and Non-residential Sharing)

0

# of Loading

2

Units / GFA

Retail & Office

Required Number of Loading Spaces

Type 'B' Type 'C' Type 'G'

0

0

0

1

1

1

0

1

1

0

1

1

2

General Notes:

1. All areas are approximate. Actual square footage may vary from that stated hereon.2. Final car parking, bicycle parking and locker count to be confirmed pending structural and mechanical input.3. All figures are reflective of the current state of schematic and conceptual design and are subject to change.4. These are preliminary numbers and are not to be relied upon for legal agreements, project valuations, sales, etc.

Green Roof Calculation

Green Roof Statistics Proposed

Gross Floor Area, as defined in Green Roof By-Law (sq.m.)

Total Roof Area (sq.m.)

Area of Residential Private Terraces (sq.m.)

Rooftop Outdoor Amenity Space, if in a Residential Building (sq.m.)

Area of Renewable Energy Devices (sq.m.)

Tower (s) Roof Area with floor plate less than 750 (sq.m.)

Total Available Roof Space (sq.m.)

Green Roof Coverage Required Proposed

Coverage of Available Roof Space (sq.m.)

Coverage of Available Roof Space (%)

Deduction in accordance with Toronto Zoning Bylaw 569-2013 which includes Exit stairwells, Mechanical rooms, Elevator shafts, Bicycle Parking and Garbage Chute. Required amenity by this by-law and above grade bicycle parking required by this by-law.

Deduction in accordance with Toronto Zoning Bylaw 438-86 which includes Mechanical rooms, Elevator shafts, Bicycle Parking and Garbage Chute (Including Surrounding Walls).Required amenity by this by-law and above grade bicycle parking required by this by-law.

(*) Toronto Zoning Bylaw 569-2013

(**) Toronto Zoning Bylaw 438-86

Level 47

Level 48

Level 49 (Residential PH)

Level 47

Level 48

43,200 465,004

1,266 13,627 1,266 13,627

43,200 465,004 43,401 467,164

10.3% 44.5% 34.3% 10.9% 100%

605 sq.ft.

54.8% 45.2%

43,200 16.5

- - - - -

- - - - -

69

258

243

64 64

69

258

243

63464570

173

807

688

49,638

2,082.1

382.8

959.7

N/A

N/A

739.6

443.8

60%

450

60%

39,843 428,868

* Above Grade

Drawing No.:

Drawn by:

Scale:Date:

Project No.:

DATEDESCRIPTIONREVISION

3- Positions of exposed or finished mechanical or electrical devices,

fittings, and fixtures are indicated on the Architectural drawings. The

locations shown on the Architectural drawings govern over the Mechanical

and Electrical drawings.

Those items not clearly located will be located as directed by the Architect.

2- Drawings are not to be scaled for construction. Contractor to verify all

existing conditions and dimensions required to perform the Work and

report any discrep-ancies with the Contract Documents to the Architect

before commencing work.

clarification or supplementary information regarding the intent of the

Contract Documents.

The Architect will review Shop Drawings submitted by the Contractor for

design conformance only.

C:\Users\alyssa\Documents\400-420 King West_alyssa.rvt

1 : 11708

JULY 04, 2019PM

A000a

STATISTICS

400-420 KING STREETWEST## StreetCity, State Zip

43,200 m2

39,818 m2

2,436 m2

N/A

N/A

633

600570

64

136

0

0

80

296

232

8

189

N/A

N/A

64

16 16

1

1

181 104 %

2957.6

57.7

57.7

57.7

57.7

57.7

57.7

57.7

57.7

57.7

57.7

57.7

57.7

57.7

57.7

57.7

57.7

57.7

57.7

57.7

57.7

57.7

57.7

57.7

57.7

57.7

57.7

57.7

57.7

57.7

57.7

57.7

57.7

57.7

57.7

57.7

57.7

57.7

64.5

64.5

64.5

64.5

64.5

57.7

74.8

64.5

64.5

64.5

109.9

65.9

3,167.4

59.0

59.0

59.0

59.0

59.0

59.0

59.0

59.0

59.0

59.0

59.0

59.0

59.0

59.0

59.0

59.0

59.0

59.0

59.0

59.0

59.0

59.0

59.0

59.0

59.0

59.0

59.0

59.0

59.0

59.0

59.0

59.0

59.0

59.0

59.0

59.0

59.0

61.9

61.9

61.9

61.9

61.9

75.9

150.8

66.0

65.6

83.7

128.1

104.7

282

8

8

8

8

8

7

7

7

7

7

7

7

7

7

7

7

7

7

7

7

7

7

7

7

7

7

7

7

7

7

7

7

8

8

8

8

5

6

6

4

65

2

2

2

2

2

1

1

1

1

1

1

1

1

1

1

1

1

1

1

1

1

1

1

1

1

1

1

1

1

1

1

2

5

5

5

5

1

2

2

2

217

4

4

4

4

4

4

4

4

4

4

4

4

4

4

4

4

4

4

4

4

4

4

4

4

4

4

4

4

4

4

4

4

4

4

4

4

4

6

7

7

7

7

3

10

10

12

69

1

1

1

1

1

1

1

1

1

1

1

1

1

1

1

1

1

1

1

1

1

1

1

1

1

1

5

5

5

5

5

5

2

4

4

3

633

14

14

14

14

14

13

13

13

13

13

13

13

13

13

13

13

13

13

13

13

13

13

13

13

13

13

13

13

13

13

13

9

9

9

9

9

9

17

20

20

20

20

9

22

22

21

44,466.3 478,631

774.0 8,331

774.0 8,331

774.0 8,331

774.0 8,331

774.0 8,331

774.0 8,331

774.0 8,331

774.0 8,331

774.0 8,331

774.0 8,331

774.0 8,331

774.0 8,331

774.0 8,331

774.0 8,331

774.0 8,331

774.0 8,331

774.0 8,331

774.0 8,331

774.0 8,331

774.0 8,331

774.0 8,331

774.0 8,331

774.0 8,331

774.0 8,331

774.0 8,331

774.0 8,331

774.0 8,331

774.0 8,331

774.0 8,331

774.0 8,331

774.0 8,331

774.0 8,331

774.0 8,331

774.0 8,331

774.0 8,331

774.0 8,331

774.0 8,331

1,111.3 11,962

1,096.6 11,803

1,096.6 11,803

1,096.6 11,803

1,096.6 11,803

738.6 7,950

1,476.2 15,889

1,505.6 16,206

1,473.7 15,863

1,457.5 15,689

1,511.1 16,266

2,167.5 23,331

44,666.9 480,791

775.3 8,345

775.3 8,345

775.3 8,345

775.3 8,345

775.3 8,345

775.3 8,345

775.3 8,345

775.3 8,345

775.3 8,345

775.3 8,345

775.3 8,345

775.3 8,345

775.3 8,345

775.3 8,345

775.3 8,345

775.3 8,345

775.3 8,345

775.3 8,345

775.3 8,345

775.3 8,345

775.3 8,345

775.3 8,345

775.3 8,345

775.3 8,345

775.3 8,345

775.3 8,345

775.3 8,345

775.3 8,345

775.3 8,345

775.3 8,345

775.3 8,345

775.3 8,345

775.3 8,345

775.3 8,345

775.3 8,345

775.3 8,345

775.3 8,345

1,108.7 11,934

1,094.0 11,775

1,094.0 11,775

1,094.0 11,775

1,094.0 11,775

758.3 8,163

1,549.6 16,679

1,507.1 16,223

1,475.0 15,876

1,476.7 15,895

1,525.6 16,422

2,204.9 23,734

3,487 37,534

1,250 13,459

2,237 24,075

44,147 475,191

833 8,967

833 8,967

833 8,967

833 8,967

833 8,967

833 8,967

833 8,967

833 8,967

833 8,967

833 8,967

833 8,967

833 8,967

833 8,967

833 8,967

833 8,967

833 8,967

833 8,967

833 8,967

833 8,967

833 8,967

833 8,967

833 8,967

833 8,967

833 8,967

833 8,967

833 8,967

833 8,967

833 8,967

833 8,967

833 8,967

833 8,967

833 8,967

833 8,967

833 8,967

833 8,967

833 8,967

833 8,967

1,173 12,628

1,158 12,469

1,158 12,469

1,158 12,469

1,158 12,469

814 8,767

1,627 17,512

1,572 16,917

1,539 16,569

1,541 16,589

389 4,185

36 383

47,634 512,725

833 8,967

833 8,967

833 8,967

833 8,967

833 8,967

833 8,967

833 8,967

833 8,967

833 8,967

833 8,967

833 8,967

833 8,967

833 8,967

833 8,967

833 8,967

833 8,967

833 8,967

833 8,967

833 8,967

833 8,967

833 8,967

833 8,967

833 8,967

833 8,967

833 8,967

833 8,967

833 8,967

833 8,967

833 8,967

833 8,967

833 8,967

833 8,967

833 8,967

833 8,967

833 8,967

833 8,967

833 8,967

1,173 12,628

1,158 12,469

1,158 12,469

1,158 12,469

1,158 12,469

814 8,767

1,627 17,512

1,572 16,917

1,539 16,569

1,541 16,589

1,639 17,645

2,272 24,458

130

53

52

25

65

65

282

282

217

217

69

692.6

1,665 17,917

1,665 17,917

960 10,3301.5

930 10,015

2,426 26,118

10931.9

633

633

10931.9

2.6

1.5

3,357 36,132

633

633

633

633

9

3

3

3

121

50

49

22

962 m2

490

N/A

N/A

8

1

1

2.8

10.2

8.1

1 ISSUED FOR SUBMISSION JUN. 26/2017

2 ISSUED FOR RE-SUNMISSION MAR.22/2018

3 ISSUED FOR SETTLEMENT OFFER APR. 22/2019

4 RE-ISSUED FOR SETTLEMENT OFFER JUN. 06/2019

5 RE-ISSUED FOR SETTLEMENT OFFER JLY. 04/2019

CC9.24 - CONFFIDENTIAL ATTACHMENT 3 - made public on July 26, 2019

Page 2: PRELIMINARY PROJECT STATISTICS...GENERAL SITE INFORMATION: SITE AREA: DENSITY (FSI): BUILDINGS: BUILDING USE: BUILDINGS AREAS: TOTAL FLOOR AREA (TFA) AND ABOVE GRADE GROSS FLOOR AREA

DNUP

1400

SIX

BA

ND

DE

CO

RA

TIV

E P

AV

ER

SA

S P

ER

EN

T. B

IA

600DOUBLE BAND

DECORATIVE PAVERSAS PER ENT. BIA

14

00

4656

30

00

PE

DE

ST

RIA

NC

LE

AR

WA

Y

13

50

LA

ND

TO

BE

CO

NV

EY

ED

TO

CIT

YF

OR

PE

DE

ST

RIA

NC

LE

AR

WA

Y

3000PEDESTRIANCLEARWAY

BICYCLE RACK(6 SPOTS)

FIREHYDRANT

STREET TREEIN TREE GRATE

STREET LIGHT

CITY BICYCLE RING(16 SPOTS)

DECORATIVEPAVING BAND

STREET TREEIN TREE GRATE

TYPICAL CITYBICYCLE RING

FIRE HYDRANT

CITY SIDEWALK CITY SIDEWALK

CIT

Y S

IDE

WA

LK

CIT

Y S

IDE

WA

LK

TYPICAL CITYBICYCLE RING

PROPERTY LINE

PR

OP

ER

TY

LIN

E

PRIVATELY OWNEDPUBLIC SPACE(PROGRAM TO BEDETAILED AT SPASTAGE)

EXTENT OFPODIUM ABOVE

FEATURE PAVING

OVERHEAD WIRE

CITY SIDEWALK

DECORATIVE PAVING BAND

BICYCLERACK(14 SPOTS)

KING STREET WEST

CH

AR

LO

TT

E S

TR

EE

T

GALLERIA

HATCH DENOTES3000 PEDESTRIAN

CLEARWAY

HATCH DENOTES LANDTO BE CONVEYED TO CITY

FOR PEDESTRIAN CLEARWAY

HATCH DENOTES3000 PEDESTRIANCLEARWAY

DASHED LINE

DENOTES EXTENT

OF SOIL CELLS

(BELOW)-

100m3 SOIL VOLUME

PROVIDED

DASHED LINE

DENOTES EXTENT

OF SOIL CELLS

(BELOW)-

120m3 SOIL VOLUME

PROVIDED

A403

1

A4041

A402 1

A401

1

A

A501

B

A502

RA

MP

DO

WN

TO

P1

EXIT

MAIL ROOM

VEST.

SERVICE / DELIVERY ROOM

BIN STORAGE SPACE(Staging Pad)

Min. 200 mm Thick Reinforced Concrete +/- 2% Slope(+- 90 m2)

SHARED TYPE G & C LOADING(4.0 X 13.0 X 6.1)

TYPE B LOADING(3.5 X 11.0 X 4.0)

CACFROOM

P1P3P4P5P7P8

Pa

Pb

Pc

Pd

P2

15,200

5,1

91

Pe

P6

MA

X.

7.5

%M

AX

. 15

%

560

4,0

00

1,7

00

3,5

00

16,065 11,000

13,000

6,0

35

6,0

18

PROPERTY LINE

PR

OP

ER

TY

LIN

E

3.6

m

0.5 m

0.9

m

0.6 m

560

0.6

m

6.0 m

EXIT

R4ELEVATOR

R5ELEVATOR

R1ELEVATOR

R2ELEVATOR

R3MOVING

ELEVATOR

ELEVATOR LOBBY

8,3

25 INTAKE

EXHAUST

6,000

R 5

000

EXTENT OF FLOOR 3 TO 6 ABOVE

5,544

RETAIL ENTRANCE

RE

SID

EN

TIA

LE

NT

RA

NC

E

6.3

m

SETBACK AT FLOORS 1 & 2

3.0 m Pedestrian Clearway

POPS

3,0

00

3,0

00

3.0 m Pedestrian Clearway

13,168

0.00

0.00

0.00

1,3

50

0.00

OF

FIC

EE

NT

RA

NC

E

6,000

6.1 m CLEAR HEIGHT ZONEAll access driveways to be used by the collection vehicle will have a maximum gradient of 8%, have a minimum vertical clearance of 4.4 metres throughout, a minimum 4.5 metres wide throughout and 6 metres wide at point of ingress and egress.

35,663

Dimension from Fire Hydrant to Siamese connections

13,912

17,734

2,000

1,200

RETAIL/OFFICELOBBYC

HA

RLO

TT

E S

TR

EE

T

KING STREET WEST

LANE

1,2

00

EXTENT OF FLOOR ABOVE

RESIDENTIALLOBBY

481.27m²5180.35ft²

RETAIL

707.97m²7620.57ft²

RETAIL

MECHANICAL

R 5

000

CORNER ROUNDING SURFACE EASEMENT WITHIN A 5.0 METRE RADIUS FOR PEDESTRIAN AND CLEARWAY

208

397

3,6

00

3,6

00

BULKY ITEM STORAGE

MOVING ROOM

INFORMAL LOADING BAY FOR

RESIDENTIAL MOVING AND MAIL DELIVERY WITH 'NO PARKING'

SIGN

UP

R6PARKING

SHUTTLE

1,600

RETAIL / OFFICEELEVATOR

300 x 3000 WARNING SIGN "CAUTION:TRUCK MANOUVERING AHEAD"

FLASHING LIGHT

8,8

05

3,1

00115.9 m2

A4061

A405

1

Drawing No.:

Drawn by:

Scale:Date:

Project No.:

General Notes:

DATEDESCRIPTIONREVISION

3- Positions of exposed or finished mechanical or electrical devices,

fittings, and fixtures are indicated on the Architectural drawings. The

locations shown on the Architectural drawings govern over the Mechanical

and Electrical drawings.

Those items not clearly located will be located as directed by the Architect.

2- Drawings are not to be scaled for construction. Contractor to verify all

existing conditions and dimensions required to perform the Work and

report any discrep-ancies with the Contract Documents to the Architect

before commencing work.

1- These Contract Documents are the property of the Architect. The

Architect bears no responsibility for the interpretations of these

documents by the Contractor.

Upon written application the Architect will provide written/graphic

clarification or supplementary information regarding the intent of the

Contract Documents.

The Architect will review Shop Drawings submitted by the Contractor for

design conformance only.

C:\Users\alyssa\Documents\400-420 King West_alyssa.rvt

1 : 1001708

JULY 04 , 2019Author

A101

GROUND FLOOR

400-420 KING STREETWEST## St reetCi ty, State Zip

NOTES:

1- "Be advised that should any party, including the applicant or any subsequent owner, apply for more than one condominium corporationEncompassing any or all of this development or make an application that results in a land division, Staff may require legal assurances, including but not limited to easements, with respect to the approved services. Such assurances will be determined at the time of application for condominium approval."

2- Second remotely located fire department connection will be provided according to NFPA 14, Standard for the Installation of Standpipe and Hose Systems which requires high rise buildings shall have at least two remotely located fire department connections for each zone. High-rise building is defined in NFPA 14 as "A building where the floor of an occupable storey is greater than 23 metres above the lowest level of fire department vehicle access."

3- The fire department connections will be within 45 metres of a fire hydrant.

4- The building will be serviced by no fewer than two sources of water supply from a public water system as the building is more than 84 metres high, measured between grade (as defined in the Ontario Building Code) and the ceiling level of the top storey. This should be shown on the site servicing drawings.

5- The Type G loading space of the multiresidential component will have a maximum gradient of 2% and will be constructed with minimum of 200 mm thick reinforced concrete.

6- The multi-residential component shall have a trained onsite staff member available to maneuver bins for the collection driver and also act as a flagman when the truck is reversing. In the event the on-site staff is unavailable at the time the City collection vehicle arrives at the site, the collection vehicle will leave the site and not return until the next scheduled collection day.

7- "Prior to solid waste collection services are to begin, City will be provided with a letter certified by a professional engineer that in all cases where a collection vehicle is required to drive onto or over a supported structure (such as an underground parking garage) the structure can safely support a fully loaded collection vehicle (35,000 kilograms) and conforms to the following:i. Design Code - Ontario Building Codeii. Design Load - City bulk lift vehicle in addition Building Code requirementsiii. Impact Factor - 5% for maximum vehicular speeds to 15 km/h and 30% for higher speeds.

8- If the non-residential component to also use of the type G loading spaces and if so, then the non-residential component will only schedule use of the type G loading space on different days from the collection days of the residential component to ensure that the Type G loading space will be vacant for City Waste Collection. If it is not planned for the non-residential component to use the type G loading spaces then this must also be noted.also the bins that will be used for the non-residential waste will be labeled separately from the bins for the residential waste.

1 ISSUED FOR SUBMISSION JUN. 26/2017

2 ISSUED FOR RE-SUNMISSION MAR.22/2018

3 ISSUED FOR SETTLEMENT OFFER APR. 22/2019

4 RE-ISSUED FOR SETTLEMENT OFFER JUN. 06/2019

5 RE-ISSUED FOR SETTLEMENT OFFER JLY. 04/2019

Page 3: PRELIMINARY PROJECT STATISTICS...GENERAL SITE INFORMATION: SITE AREA: DENSITY (FSI): BUILDINGS: BUILDING USE: BUILDINGS AREAS: TOTAL FLOOR AREA (TFA) AND ABOVE GRADE GROSS FLOOR AREA

UP

UP

A403

1

A4041

A402 1

A401

1

B

A502

930.38m²10014.57ft²

OFFICE

EXIT

P1P3P4P5P7P8

Pa

Pb

Pc

Pd

P2

Pe

P6

R6ELEVATOR

R5ELEVATOR

R1ELEVATOR

R2ELEVATOR

R3MOVING

ELEVATOR

1237.15m²13316.62ft²

RETAIL 1,200

EXTENT OF FLOOR ABOVE

EXTENT OF FLOOR ABOVE

1,6709,000

LOW HEADROOM AREA3.4m FLOOR TO CEILING

163 m²

1,1

00

DN

3.7

m

1100

RETAIL / OFFICEELEVATOR

15.5 m

3.1

m

6.00 6.90

0.5 m

0.6

m

0.6 m

0.9

m

8.6

m

13.2 m

A4061

A405

1

1.8

m

1.8

m9 m²

MALESHOWER

FACILITIES

FEMALESHOWER

FACILITIES

9 m²

1200

14.4

m

Drawing No.:

Drawn by:

Scale:Date:

Project No.:

General Notes:

DATEDESCRIPTIONREVISION

3- Positions of exposed or finished mechanical or electrical devices,

fittings, and fixtures are indicated on the Architectural drawings. The

locations shown on the Architectural drawings govern over the Mechanical

and Electrical drawings.

Those items not clearly located will be located as directed by the Architect.

2- Drawings are not to be scaled for construction. Contractor to verify all

existing conditions and dimensions required to perform the Work and

report any discrep-ancies with the Contract Documents to the Architect

before commencing work.

1- These Contract Documents are the property of the Architect. The

Architect bears no responsibility for the interpretations of these

documents by the Contractor.

Upon written application the Architect will provide written/graphic

clarification or supplementary information regarding the intent of the

Contract Documents.

The Architect will review Shop Drawings submitted by the Contractor for

design conformance only.

C:\Users\alyssa\Documents\400-420 King West_alyssa.rvt

1 : 1001708

JULY 04 , 2019Author

A102

FLOOR 2

400-420 KING STREETWEST## St reetCi ty, State Zip

1 ISSUED FOR SUBMISSION JUN. 26/2017

2 ISSUED FOR RE-SUNMISSION MAR.22/2018

3 ISSUED FOR SETTLEMENT OFFER APR. 22/2019

4 RE-ISSUED FOR SETTLEMENT OFFER JUN. 06/2019

5 RE-ISSUED FOR SETTLEMENT OFFER JLY. 04/2019

Page 4: PRELIMINARY PROJECT STATISTICS...GENERAL SITE INFORMATION: SITE AREA: DENSITY (FSI): BUILDINGS: BUILDING USE: BUILDINGS AREAS: TOTAL FLOOR AREA (TFA) AND ABOVE GRADE GROSS FLOOR AREA

Level 1

86.4

0

Level 2

92.4

0

Level 3

97.6

0

Level 5

106

.41

Level 6

109

.22

Level 7

112

.03

Level 8

115

.18

Level 9

117

.99

Level 10

120

.80

Level 11

123

.61

Level 12

127

.06

Level 13

130

.21

Level 14

133

.02

Level 15

135

.83

Level 16

138

.64

Level 17

141

.45

Level 18

144

.41

Level 19

147

.22

Level 20

150

.03

Level 21

152

.84

Level 22

155

.99

Level 23

158

.80

Level 24

161

.61

Level 25

164

.42

Level 26

167

.23

Level 27

170

.04

Level 28

173

.00

Level 29

175

.81

Level 30

178

.62

Level 31

181

.43

Level 32

184

.24

Level 33

187

.05

Level 34

189

.86

Level 35

192

.67

Level 36

195

.48

Level 37

198

.29

Level 38

201

.25

Level 39

204

.06

Level 40

206

.87

Level 41

209

.68

Level 42

212

.49

Level 43

215

.30

Level 44

218

.11

Level 45

220

.92

Level 48

229

.50

6.39 4.60

2.81 2.96 2.81 2.81 2.81 2.81 2.81 2.81 2.81 2.81 2.81 2.96 2.81 2.81 2.81 2.81 2.81 2.81 2.81 2.81 2.81 2.96 2.81 2.81 2.81 2.81 2.81 3.15 2.81 2.81 2.81 2.96 2.81 2.81 2.81 2.81 3.15 3.45 2.81 2.81 2.81 3.15 2.81 2.81 2.81 6.00 5.20 6.00

156.9 m

Level 46

223

.73

Mechan

ical/

Ele

vato

r

Overh

ead

236

.91

Level 47

226

.54

CH

AR

LOT

TE

ST

RE

ET

25.6 m

Level 4

103

.60

41.2 m

FU

TU

RE

BU

ILD

ING

AT

38

8 K

ING

ST

RE

ET

WE

ST

12.00

12

M A

S P

ER

BIR

D

FR

IEN

DLY

GU

IDL

INE

Level 49

232

.31

T.O

. M

ech R

oof

243

.30

Ele

vato

r M

ach

ine

Room

239

.63

Drawing No.:

Drawn by:

Scale:Date:

Project No.:

General Notes:

DATEDESCRIPTIONREVISION

3- Positions of exposed or finished mechanical or electrical devices,

fittings, and fixtures are indicated on the Architectural drawings. The

locations shown on the Architectural drawings govern over the Mechanical

and Electrical drawings.

Those items not clearly located will be located as directed by the Architect.

2- Drawings are not to be scaled for construction. Contractor to verify all

existing conditions and dimensions required to perform the Work and

report any discrep-ancies with the Contract Documents to the Architect

before commencing work.

1- These Contract Documents are the property of the Architect. The

Architect bears no responsibility for the interpretations of these

documents by the Contractor.

Upon written application the Architect will provide written/graphic

clarification or supplementary information regarding the intent of the

Contract Documents.

The Architect will review Shop Drawings submitted by the Contractor for

design conformance only.

C:\Users\alyssa\Documents\400-420 King West_alyssa.rvt

1 : 2001708

JULY 04 , 2019Author

A401

SOUTH ELEVATION

400-420 KING STREETWEST## St reetCi ty, State Zip

NOTES:

1- Exterior glass of the building will be designed in compliance with Bird Friendly Best Practices Guidelines.Details will be provided in Site Plan stage.

1 ISSUED FOR SUBMISSION JUN. 26/2017

2 ISSUED FOR RE-SUNMISSION MAR.22/2018

3 ISSUED FOR SETTLEMENT OFFER APR. 22/2019

4 RE-ISSUED FOR SETTLEMENT OFFER JUN. 06/2019

5 RE-ISSUED FOR SETTLEMENT OFFER JLY. 04/2019

Page 5: PRELIMINARY PROJECT STATISTICS...GENERAL SITE INFORMATION: SITE AREA: DENSITY (FSI): BUILDINGS: BUILDING USE: BUILDINGS AREAS: TOTAL FLOOR AREA (TFA) AND ABOVE GRADE GROSS FLOOR AREA

Level 1

86.4

0

Level 2

92.4

0

Level 3

97.6

0

Level 5

106

.41

Level 6

109

.22

Level 7

112

.03

Level 8

115

.18

Level 9

117

.99

Level 10

120

.80

Level 11

123

.61

Level 12

127

.06

Level 13

130

.21

Level 14

133

.02

Level 15

135

.83

Level 16

138

.64

Level 17

141

.45

Level 18

144

.41

Level 19

147

.22

Level 20

150

.03

Level 21

152

.84

Level 22

155

.99

Level 23

158

.80

Level 24

161

.61

Level 25

164

.42

Level 26

167

.23

Level 27

170

.04

Level 28

173

.00

Level 29

175

.81

Level 30

178

.62

Level 31

181

.43

Level 32

184

.24

Level 33

187

.05

Level 34

189

.86

Level 35

192

.67

Level 36

195

.48

Level 37

198

.29

Level 38

201

.25

Level 39

204

.06

Level 40

206

.87

Level 41

209

.68

Level 42

212

.49

Level 43

215

.30

Level 44

218

.11

Level 45

220

.92

Level 48

229

.50

6.39 4.60 2.81 2.96 2.81 2.81 2.81 2.81 2.81 2.81 2.81 2.81 2.81 2.96 2.81 2.81 2.81 2.81 2.81 2.81 2.81 2.81 2.81 2.96 2.81 2.81 2.81 2.81 2.81 3.15 2.81 2.81 2.81 2.96 2.81 2.81 2.81 2.81 3.15 3.45 2.81 2.81 2.81 3.15 2.81 2.81 2.81 6.00 5.20 6.00

25.6 m

41.2 m

Level 46

223

.73

Mechan

ical/

Ele

vato

r

Overh

ead

236

.91

Level 47

226

.54

KIN

G S

TR

EE

T W

EST

LA

NE

Level 4

103

.60

11

CH

AR

LOT

TE

ST

RE

ET

12

M A

S P

ER

BIR

D

FR

IEN

DLY

GU

IDL

INE

12.00

156.9 m

Level 49

232

.31

T.O

. M

ech R

oof

243

.30

Ele

vato

r M

ach

ine

Room

239

.63

FU

TU

RE

BU

ILD

ING

AT

38

8 K

ING

ST

RE

ET

WE

ST

Drawing No.:

Drawn by:

Scale:Date:

Project No.:

General Notes:

DATEDESCRIPTIONREVISION

3- Positions of exposed or finished mechanical or electrical devices,

fittings, and fixtures are indicated on the Architectural drawings. The

locations shown on the Architectural drawings govern over the Mechanical

and Electrical drawings.

Those items not clearly located will be located as directed by the Architect.

2- Drawings are not to be scaled for construction. Contractor to verify all

existing conditions and dimensions required to perform the Work and

report any discrep-ancies with the Contract Documents to the Architect

before commencing work.

1- These Contract Documents are the property of the Architect. The

Architect bears no responsibility for the interpretations of these

documents by the Contractor.

Upon written application the Architect will provide written/graphic

clarification or supplementary information regarding the intent of the

Contract Documents.

The Architect will review Shop Drawings submitted by the Contractor for

design conformance only.

C:\Users\alyssa\Documents\400-420 King West_alyssa.rvt

1 : 2001708

JULY 04 , 2019Author

A402

WEST ELEVATION

400-420 KING STREETWEST## St reetCi ty, State Zip

NOTES:

1- Exterior glass of the building will be designed in compliance with Bird Friendly Best Practices Guidelines.Details will be provided in Site Plan stage.

1 ISSUED FOR SUBMISSION JUN. 26/2017

2 ISSUED FOR RE-SUNMISSION MAR.22/2018

3 ISSUED FOR SETTLEMENT OFFER APR. 22/2019

4 RE-ISSUED FOR SETTLEMENT OFFER JUN. 06/2019

5 RE-ISSUED FOR SETTLEMENT OFFER JLY. 04/2019

Page 6: PRELIMINARY PROJECT STATISTICS...GENERAL SITE INFORMATION: SITE AREA: DENSITY (FSI): BUILDINGS: BUILDING USE: BUILDINGS AREAS: TOTAL FLOOR AREA (TFA) AND ABOVE GRADE GROSS FLOOR AREA

Level 1

86.4

0

Level 2

92.4

0

Level 3

97.6

0

Level 5

106

.41

Level 6

109

.22

Level 7

112

.03

Level 8

115

.18

Level 9

117

.99

Level 10

120

.80

Level 11

123

.61

Level 12

127

.06

Level 13

130

.21

Level 14

133

.02

Level 15

135

.83

Level 16

138

.64

Level 17

141

.45

Level 18

144

.41

Level 19

147

.22

Level 20

150

.03

Level 21

152

.84

Level 22

155

.99

Level 23

158

.80

Level 24

161

.61

Level 25

164

.42

Level 26

167

.23

Level 27

170

.04

Level 28

173

.00

Level 29

175

.81

Level 30

178

.62

Level 31

181

.43

Level 32

184

.24

Level 33

187

.05

Level 34

189

.86

Level 35

192

.67

Level 36

195

.48

Level 37

198

.29

Level 38

201

.25

Level 39

204

.06

Level 40

206

.87

Level 41

209

.68

Level 42

212

.49

Level 43

215

.30

Level 44

218

.11

Level 45

220

.92

Level 48

229

.50

6.39

4.60 2.81 2.96 2.81 2.81 2.81 2.81 2.81 2.81 2.81 2.81 2.81 2.96 2.81 2.81 2.81 2.81 2.81 2.81 2.81 2.81 2.81 2.96 2.81 2.81 2.81 2.81 2.81 3.15 2.81 2.81 2.81 2.96 2.81 2.81 2.81 2.81 3.15 3.45 2.81 2.81 2.81 3.15 2.81 2.81 2.81 6.00 5.20 6.00

156.9 m

Level 46

223

.73

Mechan

ical/

Ele

vato

r

Overh

ead

236

.91

Level 47

226

.54

CH

AR

LOT

TE

ST

RE

ET

Level 4

103

.60

FU

TU

RE

BU

ILD

ING

AT

38

8 K

ING

ST

RE

ET

WE

ST

25.6 m

Level 49

232

.31

T.O

. M

ech R

oof

243

.30

Ele

vato

r M

ach

ine

Room

239

.63

15.0 m

Drawing No.:

Drawn by:

Scale:Date:

Project No.:

General Notes:

DATEDESCRIPTIONREVISION

3- Positions of exposed or finished mechanical or electrical devices,

fittings, and fixtures are indicated on the Architectural drawings. The

locations shown on the Architectural drawings govern over the Mechanical

and Electrical drawings.

Those items not clearly located will be located as directed by the Architect.

2- Drawings are not to be scaled for construction. Contractor to verify all

existing conditions and dimensions required to perform the Work and

report any discrep-ancies with the Contract Documents to the Architect

before commencing work.

1- These Contract Documents are the property of the Architect. The

Architect bears no responsibility for the interpretations of these

documents by the Contractor.

Upon written application the Architect will provide written/graphic

clarification or supplementary information regarding the intent of the

Contract Documents.

The Architect will review Shop Drawings submitted by the Contractor for

design conformance only.

C:\Users\alyssa\Documents\400-420 King West_alyssa.rvt

1 : 2001708

JULY 04 , 2019Author

A403

NORTH ELEVATION

400-420 KING STREETWEST## St reetCi ty, State Zip

NOTES:

1- Exterior glass of the building will be designed in compliance with Bird Friendly Best Practices Guidelines.Details will be provided in Site Plan stage.

1 ISSUED FOR SUBMISSION JUN. 26/2017

2 ISSUED FOR RE-SUNMISSION MAR.22/2018

3 ISSUED FOR SETTLEMENT OFFER APR. 22/2019

4 RE-ISSUED FOR SETTLEMENT OFFER JUN. 06/2019

5 RE-ISSUED FOR SETTLEMENT OFFER JLY. 04/2019

Page 7: PRELIMINARY PROJECT STATISTICS...GENERAL SITE INFORMATION: SITE AREA: DENSITY (FSI): BUILDINGS: BUILDING USE: BUILDINGS AREAS: TOTAL FLOOR AREA (TFA) AND ABOVE GRADE GROSS FLOOR AREA

Level 1

86.4

0

Level 2

92.4

0

Level 3

97.6

0

Level 5

106

.41

Level 6

109

.22

Level 7

112

.03

Level 8

115

.18

Level 9

117

.99

Level 10

120

.80

Level 11

123

.61

Level 12

127

.06

Level 13

130

.21

Level 14

133

.02

Level 15

135

.83

Level 16

138

.64

Level 17

141

.45

Level 18

144

.41

Level 19

147

.22

Level 20

150

.03

Level 21

152

.84

Level 22

155

.99

Level 23

158

.80

Level 24

161

.61

Level 25

164

.42

Level 26

167

.23

Level 27

170

.04

Level 28

173

.00

Level 29

175

.81

Level 30

178

.62

Level 31

181

.43

Level 32

184

.24

Level 33

187

.05

Level 34

189

.86

Level 35

192

.67

Level 36

195

.48

Level 37

198

.29

Level 38

201

.25

Level 39

204

.06

Level 40

206

.87

Level 41

209

.68

Level 42

212

.49

Level 43

215

.30

Level 44

218

.11

Level 45

220

.92

Level 48

229

.50

6.39 4.60 2.81 2.96 2.81 2.81 2.81 2.81 2.81 2.81 2.81 2.81 2.81 2.96 2.81 2.81 2.81 2.81 2.81 2.81 2.81 2.81 2.81 2.96 2.81 2.81 2.81 2.81 2.81 3.15 2.81 2.81 2.81 2.96 2.81 2.81 2.81 2.81 3.15 3.45 2.81 2.81 2.81 3.15 2.81 2.81 2.81 6.00 5.20 6.00

Level 46

223

.73

Mechan

ical/

Ele

vato

r

Overh

ead

236

.91

Level 47

226

.54

KIN

G S

TR

EE

T W

EST

156.9 m

Level 4

103

.60

Level 49

232

.31

T.O

. M

ech R

oof

243

.30

Ele

vato

r M

ach

ine

Room

239

.63

FU

RU

RE

BU

ILD

ING

AT

38

8 K

ING

ST

RE

ET

WE

ST

25.6 m15.0 m

Drawing No.:

Drawn by:

Scale:Date:

Project No.:

General Notes:

DATEDESCRIPTIONREVISION

3- Positions of exposed or finished mechanical or electrical devices,

fittings, and fixtures are indicated on the Architectural drawings. The

locations shown on the Architectural drawings govern over the Mechanical

and Electrical drawings.

Those items not clearly located will be located as directed by the Architect.

2- Drawings are not to be scaled for construction. Contractor to verify all

existing conditions and dimensions required to perform the Work and

report any discrep-ancies with the Contract Documents to the Architect

before commencing work.

1- These Contract Documents are the property of the Architect. The

Architect bears no responsibility for the interpretations of these

documents by the Contractor.

Upon written application the Architect will provide written/graphic

clarification or supplementary information regarding the intent of the

Contract Documents.

The Architect will review Shop Drawings submitted by the Contractor for

design conformance only.

C:\Users\alyssa\Documents\400-420 King West_alyssa.rvt

1 : 2001708

JULY 04 , 2019Author

A404

EAST ELEVATION

400-420 KING STREETWEST## St reetCi ty, State Zip

NOTES:

1- Exterior glass of the building will be designed in compliance with Bird Friendly Best Practices Guidelines.Details will be provided in Site Plan stage.

1 ISSUED FOR SUBMISSION JUN. 26/2017

2 ISSUED FOR RE-SUNMISSION MAR.22/2018

3 ISSUED FOR SETTLEMENT OFFER APR. 22/2019

4 RE-ISSUED FOR SETTLEMENT OFFER JUN. 06/2019

5 RE-ISSUED FOR SETTLEMENT OFFER JLY. 04/2019