PRODUCT INFORMATION PreCONNECT ® OCTO

PreCONNECT OCTO PRODUCT INFORMATION · Patchcord Trunk Modul-Cassette Type B 1 to 12 Type B 1 to 12 Rx to Tx 40G 100G 200G SR4 MPO Transceiver ® PreCONNECT ® OCTO ® Breakout-Trunk

  • Upload
    vanhanh

  • View
    221

  • Download
    0

Embed Size (px)

Citation preview

PRODUCT INFORMATION

PreCONNECT® OCTO

PRODUCT INFORMATION | PreCONNECT® OCTO

Product information: Produktinfo_PreCONNECT_OCTO_oe_005 Author: Harald Jungbäck Page 2 of 34

PreCONNECT® OCTO Breakout-Trunk PreCONNECT® OCTO Patchcords and Multijumper

Patch Location Rack

PreCONNECT® OCTO Harness

Accessories

LC-COMPACT Patchcords

PreCONNECT®

SMAP-G2 and SMAP-G2 HIGH-DENSITY

19” Panel Systems

PRODUCT INFORMATION | PreCONNECT® OCTO

Product information: Produktinfo_PreCONNECT_OCTO_oe_005 Author: Harald Jungbäck Page 3 of 34

Application: System description:

MTP® (MPO) based Data Center cabling with 8 fibers per MTP

® channel:

Optimized for parallel optics applications:

40/100/200 GBASE-SR4 4x16 und 4x32 GFC 100G PSM4 4x10 GBASE-LR 400GBASE-DR4

Easy migration to 400 GBASE-SR8 and SR16.

Our PreCONNECT® OCTO cabling system consists of:

OCTO Breakout-Trunk called factory assembled FO cables with up to 24 SR4 or PSM4 MTP

® channels (24x8=192 fibers).

19” Panel Systems with Part-Front-Plates with MTP®/MPO Adapters

and OCTO Module-Cassettes OCTO Patchcords, Multijumpers and Harnesses Useful accessories Patch Location Racks

Rosenberger OSI brought already 1991 high fibercount factory assem-

bled FO Trunk cables to the market. PreCONNECT® STANDARD was

the first in Europe developed and manufactured, high fibercount and modular „plug-and-play“ FO cabling system and already 1997 we have been the first manufacturer of MTP

® cabling systems in Europe.

Properties:

PreCONNECT® square-interface and installation protection:

PreCONNECT® OCTO Breakout-Trunks have PreCONNECT

® square-interfaces on both sides which can

be tool-less hooked into the 19” Panel Systems for tensile and torsion resistant fixing of the Trunks.

The Trunk connector legs are fitting for the 19“ Panel Systems and are packaged in non pull resistant

dust-proof foil tubes. On request with tensile strength, crush resistant, kink and torsion resistant, installa-

tion tubes deliverable.

PRODUCT INFORMATION | PreCONNECT® OCTO

Product information: Produktinfo_PreCONNECT_OCTO_oe_005 Author: Harald Jungbäck Page 4 of 34

Properties:

Connector types:

OCTO Breakout-Trunks: MTP® 12 fiber male with OCTO fiber assignment

OCTO Patchcords, Multijumpers, Harnesses and Module-Cassettes: MTP® 12 fiber female with

OCTO fiber assignment

Adapter types:

MTP®

multimode: TIA Typ B „1 to 12“ Grey

MTP®

singlemode TIA Typ A „1 to 1“ Green

Description of the adapter types A and B see last pages of in this document

Coding/polarity:

OCTO Breakout-Trunks:

- Multimode: TIA Methode B „1 to 12“ Grey

- Singlemode TIA Methode A „1 to 1“ Green

OCTO Patchcords, Harnesses and Module-Cassettes: See pages of the products

Cable types:

PreCONNECT® OCTO Breakout-Trunks: I-F(ZN)HH n x 8 fibers

PreCONNECT® OCTO Patchcords and Harnesses I-F(ZN)H and I-F(ZN)H(ZN)H 8 fibers

Kabeldaten siehe separate Kabeldatenblätter

Fiber types:

Multimode OM4 bend-insensitive for SR4

Singlemode G.657.A1 bend-insensitive and backwards compatible to G.652.D for PSM4

Fiber data, see separate fiber data sheets.

Length definition: Order-length = length between the connectors of the longest legs at both sides, not between the Pre-CONNECT

® square-interfaces.

Delivery form: Dependent on the length as cable ring or on cardboard or wooden drum, 100% IL factory measured with measurement protocol, product label with serial number on both sides.

I-F(ZN)HH 6 x 8 fiber Breakoutcable

TIA Type B „1 to 12“ Grey

TIA Type A „1 to 1“ Green

PRODUCT INFORMATION | PreCONNECT® OCTO

Product information: Produktinfo_PreCONNECT_OCTO_oe_005 Author: Harald Jungbäck Page 5 of 34

MULTIMODE

Patchcord Trunk Patchcord

Type B 1 to 12 Type B 1 to 12 Type B 1 to 12

Daisy chain: Patchcord Trunk Patchcord Trunk Patchcord

Type B 1 to 12 Type B 1 to 12 Type B 1 to 12 Type B 1 to 12 Type B 1 to 12

40G

100G

200G

SR4 MPO

Transceiver

40G

100G

200G

SR4 MPO

Transceiver

PreCONNECT®

OCTO Breakout-Trunk

PreCONNECT®

OCTO

Patchcords and

Multijumper

PreCONNECT®

OCTO

Patchcords and

Multijumper

PreCONNECT®

SMAP-G2 19“ Panel System

OM4 fiber max. channel length 100 meter

PreCONNECT® OCTO application case Point-to-Point: 40 / 100 / 200 GBASE-SR4 MPO-MPO

4x16 / 4x32 GFC MPO-MPO

PRODUCT INFORMATION | PreCONNECT® OCTO

Product information: Produktinfo_PreCONNECT_OCTO_oe_005 Author: Harald Jungbäck Page 6 of 34

MULTIMODE

Patchcord Trunk Harness

Type B 1 to 12 Type B 1 to 12 Rx to Tx

40G

100G

200G

SR4 MPO

Transceiver

PreCONNECT®

OCTO Breakout-Trunk

PreCONNECT®

OCTO

Patchcords and Multijumper

PreCONNECT®

SMAP-G2 19“ Panel System

OM4 fiber max. channel length 100 meter

10G

25G

50G

SR LC-Duplex Transceiver

PreCONNECT®

OCTO

Harness

PreCONNECT® OCTO application case Port-Breakout with Harness: 40 / 100 / 200 GBASE-SR4 MPO to 4x10 / 4x25 / 4x50 GBASE-SR LC-Duplex

4x16 / 4x32 GFC MPO to 4x16 / 4x 32 GFC LC-Duplex

PRODUCT INFORMATION | PreCONNECT® OCTO

Product information: Produktinfo_PreCONNECT_OCTO_oe_005 Author: Harald Jungbäck Page 7 of 34

MULTIMODE

LC-Compact

Patchcord

Tx1 Rx1

Rx1 Tx1

Tx2 Rx2

Rx2 Tx2

Tx3 Rx3

Rx3 Tx3

Tx4 Rx4

Rx4 Tx4

Tx1

Rx1

Tx2

Rx2

Tx3

Rx3

Tx4

Rx4

Patchcord Trunk Modul-Cassette

Type B 1 to 12 Type B 1 to 12 Rx to Tx

40G

100G

200G

SR4 MPO

Transceiver

PreCONNECT®

OCTO Breakout-Trunk

PreCONNECT®

OCTO

Patchcords and Multijumper

PreCONNECT®

SMAP-G2 19“ Panel System

OM4 fiber max. channel length 100 meter

PreCONNECT®

OCTO Module-Cassette

LC-Compact

Patchcord

10G

25G

50G

SR LC-Duplex Transceiver

PreCONNECT® OCTO application case Port-Breakout with Module-Cassette: 40 / 100 / 200 GBASE-SR4 MPO to 4x10 / 4x25 / 4x50 GBASE-SR LC-Duplex

4x16 / 4x32 GFC MPO to 4x16 / 4x 32 GFC LC-Duplex

PRODUCT INFORMATION | PreCONNECT® OCTO

Product information: Produktinfo_PreCONNECT_OCTO_oe_005 Author: Harald Jungbäck Page 8 of 34

SINGLEMODE

Patchcord Trunk Patchcord

Type A 1 to 1 Type A 1 to 1 Type B 1 to 12

Daisy chain: Patchcord Trunk Patchcord Trunk Patchcord

Type A 1 to 1 Type A 1 to 1 Type A 1 to 1 Type A 1 to 1 Type B 1 to 12

PSM4

MPO Transceiver

PreCONNECT®

OCTO Breakout-Trunk PreCONNECT

®

OCTO

Patchcords and

Multijumper

PreCONNECT®

OCTO

Patchcords and

Multijumper

PreCONNECT®

SMAP-G2 19“ Panel System

SM fiber max. channel length acc. to application and Transceiver data sheet

PSM4

MPO Transceiver

PreCONNECT® OCTO application case Point-to-Point:

100G PSM4 MPO-MPO

4x10 GBASE-LR MPO-MPO

400GBASE-DR4 MPO-MPO

PRODUCT INFORMATION | PreCONNECT® OCTO

Product information: Produktinfo_PreCONNECT_OCTO_oe_005 Author: Harald Jungbäck Page 9 of 34

PreCONNECT® OCTO application case Port-Breakout with Harness:

100G PSM4 MPO to 4x25 GBASE-LR LC-Duplex

SINGLEMODE

PreCONNECT® OCTO application case Port-Breakout with Module-Cassette: 100G PSM4 MPO auf 4x25 GBASE-LR LC-Duplex

Patchcord Trunk Harness

Type A 1 to 1 Type A 1 to 1 Rx to Tx

LC-Compact

Patchkabel

Tx1 Rx1

Rx1 Tx1

Tx2 Rx2

Rx2 Tx2

Tx3 Rx3

Rx3 Tx3

Tx4 Rx4

Rx4 Tx4

Tx1

Rx1

Tx2

Rx2

Tx3

Rx3

Tx4

Rx4

Patchcord Trunk Module-Cassette

Type A 1 to 1 Type A 1 to 1 Rx auf Tx

PRODUCT INFORMATION | PreCONNECT® OCTO

Product information: Produktinfo_PreCONNECT_OCTO_oe_005 Author: Harald Jungbäck Page 10 of 34

PreCONNECT® OCTO SR4 OM4 Breakout-Trunk M U L T I M O D E

Breakout-Cable n x 8 OM4 fibers FRNC-LSZH

MTP® 12 male with OCTO fiber assignment

Coding/polarity TIA method B “1 to 12”

MTP® leg-length = standard stepped

Part numbers, length variable: 4 OCTO channels: 037A2049OM4 8 OCTO channels: 037A2050OM4 12 OCTO channels : 037A2051OM4 24 OCTO channels : 037A2067OM4

Breakout-Cable I-F(ZN)HH n x 8

OCTO

channels Structure Fiber count Diameter

4 4 x 8 32 8,9 mm

8 8 x 8 64 13,1 mm

12 12 x 8 96 16,5 mm

24 24 x 8 192 14,2 mm

With PreCONNECT® square-interface

on both sides

PRODUCT INFORMATION | PreCONNECT® OCTO

Product information: Produktinfo_PreCONNECT_OCTO_oe_005 Author: Harald Jungbäck Page 11 of 34

PreCONNECT® OCTO PSM4 SM Breakout-Trunk S I N G L E M O D E

Breakout-Cable n x 8 OM4 fibers FRNC-LSZH

MTP® 12 male with OCTO fiber assignment

Coding/polarity TIA method A “1 to 1”

MTP® leg-length = standard stepped

Part numbers, length variable: 4 OCTO channels: 037A2063G657A1 8 OCTO channels: 037A2064G657A1 12 OCTO channels: 037A2065G657A1

Breakout-Cable I-F(ZN)HH n x 8

OCTO

channels Structure Fiber count Diameter

4 4 x 8 32 8,9 mm

8 8 x 8 64 13,1 mm

12 12 x 8 96 16,5 mm

With PreCONNECT® square-interface

on both sides

PRODUCT INFORMATION | PreCONNECT® OCTO

Product information: Produktinfo_PreCONNECT_OCTO_oe_005 Author: Harald Jungbäck Page 12 of 34

PreCONNECT® SMAP-G2 19” Panel System with 1HU Part-Front-Plates PFP

Part number

SMAP-G2 19” Empty Panel 1 HU 171A0001

RAL 9005 (black) 2 HU 172A0001

3 HU 173A0001

5 HU 175A0001

PFP-Type Number and adapter type SMAP-G2 Part Front Plate Part numbers (black)

1HU ¼ Blind-PFP 170A0001

1HU ½ Blind-PFP 170A0002

1HU ¼ 6 MTP®

Type B „Key-up to Key-up“ grey for SR4 OM4 170A0630TB

1HU ½ 12 MTP®

Type B „Key-up to Key-up“ grey for SR4 OM4 170A0670TB

1HU ¼ 6 MTP®

Type A „Key-up to Key-down“ green for PSM4 SM 170A0620

1HU ½ 12 MTP®

Type A „Key-up to Key-down“ green for PSM4 SM 170A0660

PRODUCT INFORMATION | PreCONNECT® OCTO

Product information: Produktinfo_PreCONNECT_OCTO_oe_005 Author: Harald Jungbäck Page 13 of 34

Part numbers

Number of OCTO channels

OCTO MTP® female interfaces

at the back plane

Number of

LC-Duplex interfaces

at the front plane

OM4 for SR4 SM for PSM4

2 2 OCTO groups of 4 = 8 170A2020OM4 170A2030

PreCONNECT® OCTO Module-Cassettes

for SMAP-G2 with 1HU Part-Front-Plates PFP

Properties: For Port-Breakout of PreCONNECT

® OCTO Breakout-Trunks, as described

in the application cases earlier in this document Height: 1HU Width: ¼ Coding/Polarity: Rx to Tx OCTO MTP

® female interfaces at the back plane

LC-Duplex interfaces at the front plane

PRODUCT INFORMATION | PreCONNECT® OCTO

Product information: Produktinfo_PreCONNECT_OCTO_oe_005 Author: Harald Jungbäck Page 14 of 34

PreCONNECT® SMAP-G2 HIGH-DENSITY 19” Gehäusesystem mit 1/3 HE Teilfrontplatten TFP

Bestellnummern

SMAP-G2 HD 19” Leergehäuse 1 HE 171H0001

RAL 9005 (schwarz) 2 HE 172H0001

TFP-Typ Anzahl Kupplungstyp SMAP-G2 Teilfrontplatten Bestellnummern (schwarz)

1/3HU ¼ Blind-TFP 170H0001

1/3HU ¼ 6 MTP®

Typ B „Key-up to Key-up“ grau für SR4 OM4 170H2013TB

1/3HU ¼ 6 MTP®

Typ A „Key-up to Key-down“ grün für PSM4 SM 170H2023

PRODUCT INFORMATION | PreCONNECT® OCTO

Product information: Produktinfo_PreCONNECT_OCTO_oe_005 Author: Harald Jungbäck Page 15 of 34

Part numbers

Number of OCTO channels

OCTO MTP® female interfaces

at the back plane

Number of

LC-Duplex interfaces

at the front plane

OM4 for SR4 SM for PSM4

1 1 OCTO group of 4 = 4 170H1010OM4 170H1020

PreCONNECT® OCTO Modul-Kassetten

for SMAP-G2 HIGH-DENSITY with 1/3 HU Part-Front-Plates PFP

Properties: For Port-Breakout of PreCONNECT

® OCTO Breakout-Trunks, as described

in the application cases earlier in this document Height: 1/3 HU Width: ¼ Coding/Polarity: Rx to Tx OCTO MTP

® female interfaces at the back plane

LC-Duplex interfaces at the front plane

PRODUCT INFORMATION | PreCONNECT® OCTO

Product information: Produktinfo_PreCONNECT_OCTO_oe_005 Author: Harald Jungbäck Page 16 of 34

PreCONNECT® OCTO SR4 OM4 Patchcord M U L T I M O D E

Single jacket: Single jacket cable 8 OM4 fibers FRNC-LSZH

Diameter 3 mm

MTP® 12 female with OCTO fiber assignment

Coding/polarity TIA method B “1 to 12”

Part number, length variable: 080A2030OM4

Double jacket: Double jacket cable 8 OM4 fibers FRNC-LSZH

Diameter 3/4.5 mm

MTP® 12 female with OCTO fiber assignment

Standard lengths of the 3mm single jacket MTP®-

legs = 0.5m, others on request

Part number, length variable: 080A2031OM4

On request deliverable with PreCONNECT®

square-interface

PreCONNECT® OCTO Patchcords coding/polarity TIA method B “1 to 12” are suitable for Transceiver-Transceiver direct-attach.

PRODUCT INFORMATION | PreCONNECT® OCTO

Product information: Produktinfo_PreCONNECT_OCTO_oe_005 Author: Harald Jungbäck Page 17 of 34

PreCONNECT® OCTO PSM4 SM Patchcords S I N G L E M O D E

Single jacket: Single jacket cable 8 SM fibers FRNC-LSZH

Diameter 3 mm

MTP® 12 female with OCTO fiber assignment

Part numbers, length variable: Coding/polarity TIA method A “1 to 1” 080A2043G657A1 Coding/polarity TIA method B “1 to 12” 080A2036G657A1

Double jacket: Double jacket cable 8 SM fibers FRNC-LSZH

Diameter 3/4.5 mm

MTP® 12 female with OCTO fiber assignment

Standard lengths of the 3mm single jacket MTP®-

legs = 0.5m, others on request

Part numbers, length variable: Coding/polarity TIA method A “1 to 1” 080A2044G657A1

Coding/polarity TIA method B “1 to 12” 080A2045G657A1

On request deliverable with PreCONNECT®

square-interface

PreCONNECT® OCTO Patchcords coding/polarity TIA method B “1 to 12” are suitable for Transceiver-Transceiver direct-attach.

PRODUCT INFORMATION | PreCONNECT® OCTO

Product information: Produktinfo_PreCONNECT_OCTO_oe_005 Author: Harald Jungbäck Page 18 of 34

PreCONNECT® OCTO SR4 OM4 Multijumper (Multipatchcord) M U L T I M O D E

Breakout-Cable n x 8 OM4 fibers FRNC-LSZH

MTP® 12 female with OCTO fiber assignment

Coding/polarity TIA method B “1 to 12”

MTP® leg-length = variable

Part numbers, length variable: 4 OCTO channels: 037A2052OM4 8 OCTO channels : 037A2053OM4 12 OCTO channels : 037A2054OM4

Breakout-Cable I-F(ZN)HH n x 8

OCTO

channels Structure Fiber count Diameter

4 4 x 8 32 8,9 mm

8 8 x 8 64 13,1 mm

12 12 x 8 96 16,5 mm

On request deliverable with PreCONNECT®

square-interface

PreCONNECT® OCTO Multijumper coding/polarity TIA method B “1 to 12” are suitable for Transceiver-Transceiver direct-attach.

PRODUCT INFORMATION | PreCONNECT® OCTO

Product information: Produktinfo_PreCONNECT_OCTO_oe_005 Author: Harald Jungbäck Page 19 of 34

PreCONNECT® OCTO PSM4 SM Multijumper (Multipatchcord) S I N G L E M O D E

Breakout-Cable n x 8 OM4 fibers FRNC-LSZH

MTP® 12 female with OCTO fiber assignment

MTP® leg-length = variable

Part numbers, length variable: Coding/polarity TIA method A “1 to 1” 4 OCTO channels: 037A2057G657A1 8 OCTO channels: 037A2058G657A1 12 OCTO channels: 037A2059G657A1 Coding/polarity TIA method B “1 to 12” 4 OCTO channels: 037A2060G657A1 8 OCTO channels: 037A2061G657A1 12 OCTO channels: 037A2062G657A1

Breakout-Cable I-F(ZN)HH n x 8

OCTO

channels Structure Fiber count Diameter

4 4 x 8 32 8,9 mm

8 8 x 8 64 13,1 mm

12 12 x 8 96 16,5 mm

On request deliverable with PreCONNECT®

square-interface

PreCONNECT® OCTO Multijumper coding/polarity TIA method B “1 to 12” are suitable for Transceiver-Transceiver direct-attach.

PRODUCT INFORMATION | PreCONNECT® OCTO

Product information: Produktinfo_PreCONNECT_OCTO_oe_005 Author: Harald Jungbäck Page 20 of 34

PreCONNECT® OCTO SR4 OM4 Harness M U L T I M O D E

For connecting a SR4 MPO Transceiver with four LC-Duplex-Transceivers and for Port-Breakout of OCTO Trunks: Ex.: - QSFP 40GBASE-SR4 to four SFP+ 10GBASE-SR/SW - QSFP 100GBASE-SR4 to four SFP+ 25GBASE-SR/SW - QSFP 4x16 GFC to four SFP+ 16 GFC / 4x32 GFC to four SFP+ 32 GFC

OCTO SR4 OM4 Harness MTP® 12 female to 4 LC-Compact Double jacket cable 8 OM4 fibers 3/4.5 mm FRNC-LSZH LC-Compact leg-lengths 0.5m, legs numbered 1 to 4 other leg lengths on request Order length = total length Part number coding Rx to Tx: 076A0112OM4

On request deliverable with PreCONNECT®

square-interface

PRODUCT INFORMATION | PreCONNECT® OCTO

Product information: Produktinfo_PreCONNECT_OCTO_oe_005 Author: Harald Jungbäck Page 21 of 34

PreCONNECT® OCTO PSM4 SM Harness S I N G L E M O D E

For connecting a PSM4 MPO Transceiver with four LC-Duplex-Transceivers and for Port-Breakout of OCTO Trunks: Ex.: - QSFP 100G PSM4 to four SFP+ 25GBASE-LR - QSFP 4x10GBASE-LR to four SFP+ 10GBASE-LR

OCTO PSM4 SM Harness MTP® 12 female to 4 LC-Compact Double jacket cable 8 SM fibers 3/4.5 mm FRNC-LSZH LC-Compact leg-lengths 0.5m, legs numbered 1 to 4 other leg lengths on request Order length = total length Part number coding Rx auf Tx: 076A0116G657A1

On request deliverable with PreCONNECT®

square-interface

PRODUCT INFORMATION | PreCONNECT® OCTO

Product information: Produktinfo_PreCONNECT_OCTO_oe_005 Author: Harald Jungbäck Page 22 of 34

Part numbers Duplex Patchcord cable type round I-V(ZN)H FRNC-LSZH

Cable diameter Connectors Length OM4 SM

2.0mm LC-Compact » LC-Compact variable 087A6623OM4 087A6620G657A1

2.8mm LC-Compact » LC-Compact variable 087A6601OM4 087A6600G657A1

Double-Jacket 2.8/5.0mm

LC-Compact » LC-Compact variable 087A6613OM4 087A6610G657A1

Patchcords with LC-COMPACT connectors for SMAP-G2 19” Panel System

Properties: Suitable only for the low density of the SMAP-G2 19” Panel System Kink and crush resistance optimized for environmental conditions Suitable for operation in temperatures from -10 °C to +60 °C Coding/Polarity:

Full-duplex cables with duplex connectors on both sides “crossed” A to B in accordance with ISO/IEC 11801 and EN 50173

Length tolerances: Up to 1 m = - 50 mm 2 m to 3 m = - 100 mm 4 m to 25 m = - 200 mm Longer than 25 m = - 1 %

Delivery form: Attenuation measured in accordance with IEC 61300-3-4 „C“ or „Substitu-

tion“ method, measurement values on request Serial number labels at the cable ends on both sides Individually packaged in foil bags with product ID label

PRODUCT INFORMATION | PreCONNECT® OCTO

Product information: Produktinfo_PreCONNECT_OCTO_oe_005 Author: Harald Jungbäck Page 23 of 34

Part numbers Duplex Patchcord cable type round I-V(ZN)H FRNC-LSZH

Cable diameter Connectors Length OM4 SM

2.0mm LC-Compact HD » LC-Compact HD Variable 087A6655OM4 087A6654G657A1

2.8mm LC-Compact HD » LC-Compact HD variable 087A6638OM4 087A6644G657A1

Double-Jacket 2.8/5.0mm

LC-Compact HD » LC-Compact HD variable 087A6653OM4 087A6652G657A1

Patchcords with LC-COMPACT HIGH-DENSITY connectors with Pulltab

for SMAP-G2 HIGH-DENSITY 19” Panel System

Properties: Required for the high density of the SMAP-G2 HIGH-DENSITY

19” Panel System Kink and crush resistance optimized for environmental conditions Suitable for operation in temperatures from -10 °C to +60 °C Coding/Polarity:

Full-duplex cables with duplex connectors on both sides “crossed” A to B in accordance with ISO/IEC 11801 and EN 50173

Length tolerances: Up to 1 m = - 50 mm 2 m to 3 m = - 100 mm 4 m to 25 m = - 200 mm Longer than 25 m = - 1 %

Delivery form: Attenuation measured in accordance with IEC 61300-3-4 „C“ or „Substitu-

tion“ method, measurement values on request Serial number labels at the cable ends on both sides Individually packaged in foil bags with product ID label

PRODUCT INFORMATION | PreCONNECT® OCTO

Product information: Produktinfo_PreCONNECT_OCTO_oe_005 Author: Harald Jungbäck Page 24 of 34

Part number

19” 1 HU Universal Trunk Cable Divider Holder For the universal installation of trunk cable

dividers in 19" cabinets and racks.

RAL 9005 (black)

099A0085

19” 1 HU Individual Universal Trunk Cable Di-vider Holder For the universal installation of trunk cable

dividers in 19" cabinets or racks or anywhere

where these components can be installed

individually.

RAL 9005 (black)

099A0065

19” Horizontal Cable Manager RAL 9005 (black) 1 HU 2 HU

111A0454 111A0453

19” Cable Overlength Panel to be mounted be-

hind Cable Managers to store Trunk cable over-

lengths

RAL 9005 (black)

1 HU 2 HU Cable Managers must be ordered separately.

142A0530 142A0531

Accessories:

PRODUCT INFORMATION | PreCONNECT® OCTO

Product information: Produktinfo_PreCONNECT_OCTO_oe_005 Author: Harald Jungbäck Page 25 of 34

Part number

Labeling Fields Suitable for all Rosenberger OSI panels and most

commercially available panels, comprising:

- 1 labeling field - Mounting material - Mounting instructions

1 HU 2 HU 3 HU 4 HU 5 HU

171A0002 172A0002 173A0002 174A0002 175A0002

1 HU Patchcord Guides For routing and fixing patchcords per height unit.

1 HU to both sides. The patchcord guide prevents

excessively small bending radii which increase

attenuation in the patchcord. Set consisting of 1 HU

left-hand and right-hand patchcord guides with

labeling fields and Velcro strips, M6 screws and

cage nuts. Suitable for use in 600 mm wide cabi-

nets.

For 1 HU Panel For 2 HU Panel For 3 HU Panel For 4 HU Panel For 5 HU Panel

171A0006 172A0006 173A0006 174A0006 175A0006

Accessories:

PRODUCT INFORMATION | PreCONNECT® OCTO

Product information: Produktinfo_PreCONNECT_OCTO_oe_005 Author: Harald Jungbäck Page 26 of 34

Bestellnummer

Patchcord Guides with foldaway labeling field For routing and fixing patchcords to both sides. The patchcord guide prevents excessively small bend-ing radii which increase attenuation in the patch-cord. The foldaway labeling field can be opened for patching. RAL 9005 (black) 1 HU 2 HU

170H0005 170H0006

Accessories:

PRODUCT INFORMATION | PreCONNECT® OCTO

Product information: Produktinfo_PreCONNECT_OCTO_oe_005 Author: Harald Jungbäck Page 27 of 34

Patch Location Rack:

Applications: High-density data center infrastructures For the construction of ultra-high-density data center patch locations

Properties: Innovative, restriction-free cable management system Rack pillars with integrated cable managers to prevent interference with cable routing The covers of the cable managers fold in both directions and are completely removable Individually selectable feedthroughs in the sides and rear walls of the large-volume cable channel for

simple vertical and horizontal cable routing Professional routing of large cable volumes from the patchfields and storage of cable overlengths in the

vertical cable managers Particularly suitable for fiber optic cables thanks to the use of cable clips (L-fingers) and finger slots:

- The rounded L-fingers ensure that the cables are extremely well protected against bending and kinking even when subject to strain.

- The L-fingers do not have any sharp edges and are extremely strong and resistant to breakage. - Because there is plenty of space for them in the large finger slots, the cables are neither squeezed nor

kinked. - The L-fingers retain the cables in the finger slots whenever you need to work with the covers folded

back or removed. Dimensions (H x L x W): 213 (46 HU) x 90 x 90 cm Material and color: Powder-coated steel, RAL 9005 (black)

Optional: 19” Intermediate Rack for the construction of rack rows with uneven numbers of racks on request. Delivery form: Factory-mounted on pallet (total height with pallet and packaging: 230 cm) Including adjustable feet for on-site installation

Accessories: Wide range of accessories such as side walls, cable guides, excess cable storage for the top of the rack are available on request

More details in our

Product Information “ DC-PLR“

PRODUCT INFORMATION | PreCONNECT® OCTO

Product information: Produktinfo_PreCONNECT_OCTO_oe_005 Author: Harald Jungbäck Page 28 of 34

PreCONNECT® OCTO – TECHNOLOGY AND BASICS

The connectivity system of multimode Parallel Optics is MTP®/MPO

MTP® = „Mechanical Transfer Push-On“, is a registered trademark of US

Conec Ltd., since 1997 on the market

Standardized since 2000 in IEC 61754-7 as MPO = „Multifiber Push-On“ or „Multipath Push-On“

MTP®/MPO is the fiber optic connectivity system with the highest densi-

ty, 4 to 72 fibers

Already in 1997 we have been the first manufacturer of MTP® cabling

systems in Europe, through initiative of IBM

We are one of only a few worldwide IBM MTP® qualified manufacturers

We have been the first European partner of the MTP

® inventor and pa-

tent owner US Conec Ltd., and we are the largest MTP® assembler in

Europe

One connection consists of:

a „female“ connector without pins but pin holes … … a „male“ connector with pins … … and the adapter.

PRODUCT INFORMATION | PreCONNECT® OCTO

Product information: Produktinfo_PreCONNECT_OCTO_oe_005 Author: Harald Jungbäck Page 29 of 34

PreCONNECT® OCTO – TECHNOLOGY AND BASICS

MTP®/MPO adapters

are only mechanical fixture, fiber positioning through „male“ pins in „female“ holes of the ferrules according to ANSI/TIA-568-B.1-7, two designs of MTP

® adapters are existing

Type A „Key-up to Key-down“ mated connection

Coding/polarity „1 to 1“

Type B „Key-up to Key-up“ (aligned key) mated connection

Coding/polarity „1 to 12“

Hence singlemode MTP® connectors are usually APC 8°, singlemode

MTP® adapters must be Type A „Key-up to Key-down“.

MTP® adapter colors:

Type A „Key-up to Key-down“: OM2 = black, OM3 = aqua, OM4 = violet, SM = green since APC 8°

Type B „Key-up to Key-up“: grey for all fiber types

PRODUCT INFORMATION | PreCONNECT® OCTO

Product information: Produktinfo_PreCONNECT_OCTO_oe_005 Author: Harald Jungbäck Page 30 of 34

PreCONNECT® OCTO – TECHNOLOGY AND BASICS

OCTO multimode products comprise MTP

® multimode Elite

® fer-

rules, which is necessary through the low power budget of the SR4 applica-tions.

The Insertion Loss (IL) of connections within channels:

89% of all 12 fiber connections have less than 0.25 dB attenua-tion

OCTO singlemode

products comprise MTP® singlemode

standard ferrules, which is sufficient for the power budget of the PSM4 ap-plications.

Source: US Conec Ltd.

MULTIMODE

PRODUCT INFORMATION | PreCONNECT® OCTO

Product information: Produktinfo_PreCONNECT_OCTO_oe_005 Author: Harald Jungbäck Page 31 of 34

PreCONNECT® OCTO – TECHNOLOGY AND BASICS

OCTO fiber assignment

SR4 multimode and PSM4 singlemode Parallel Optics applications 40/100/200GBASE-SR4, 4x16/4x32G Fiber Channel, InfiniBand

® 4x, PSM4

QSFP SR4 or

PSM4 MPO 12 Transceiver

QSFP SR4 or

PSM4 MPO 12 Transceiver

SR4 and PSM4 MPO Transceivers are male (with pins)

MPO/MTP® connectors must be female (without pins) and must have 12

fiber matrix

The singlemode MPO/MTP®

connectors for PSM4 must be APC 8°, female, 12 fiber matrix

PRODUCT INFORMATION | PreCONNECT® OCTO

Product information: Produktinfo_PreCONNECT_OCTO_oe_005 Author: Harald Jungbäck Page 32 of 34

PreCONNECT® OCTO – TECHNOLOGY AND BASICS

Coding/polarity: The coding/polarity within Parallel Optics channels must ensure the connection of transmitter Tx1 of

the Transceiver at one end with the Receiver Rx1 of the Transceiver at the other end and Tx2 with

Rx2, Tx3 with Rx3, etc.

With Parallel Optics applications having Transceiver or Transmitter and Receiver with 12 fiber MTP®

interfaces, polarity / coding must be : fiber position 1 of the MTP® at one end must be linked with fiber

position 12 of the MTP® at the other end, the light must propagate from 1 to 12.

The fiber positions within MTP®

connectors are

counted from the side with the white mark.

1 2 3 4 . . . . 9 10 11 12 fiber positions

TIA method/type B “1 to12” is the SR4 and PSM4 coding/polarity:

PRODUCT INFORMATION | PreCONNECT® OCTO

Product information: Produktinfo_PreCONNECT_OCTO_oe_005 Author: Harald Jungbäck Page 33 of 34

PreCONNECT® OCTO – TECHNOLOGY AND BASICS

Channel specifications

40GBASE-SR4 100/200GBASE-SR4

400GBASE-SR16

BROCADE

4x16 / 4x32 GFC PSM4

IEEE 802.3 R-O

Length

max. [m]

OM3 100 140 70 66 / 70 -

OM4 150 170 100 100 / 100 -

SM - - - - 500

Attenuation

max. [dB]

OM3 1,9 1,9 1,8 1,9 -

OM4 1,5 1,5 1,9 1,5 -

SM - - - - 3,26

R-O = channel lengths possible with Rosenberger-OSI OM3 and OM4 fibers

Skew specifications:

Skew = time delay of related parallel running parts of a signal.

40/100/200/400GBASE-SR4 max. 2,2ns PSM4 max 2,4ns

Skew variation for the entire cabling channel (possible through electronic Skew compensation). .

Our internal measurement result: Approx. 1,5ns Skew at both 150m of Loose-Tube-Cable and Ribbon cable. 1ns is left for stepped Trunk connector legs:

Trunks are allowed to be made of Loose-Tube-Cables. A diverse length of our Trunk connector legs does not cause too high

Skew. It must not be Trunks with same MTP

® leg lengths and they must not

be made of Ribbon cable. Transmission works without problems over classical Loose-Tube-Cable Trunks with duplex connectors, attached by Migration-Harnesses, see „Migration“ in this document.

Rosenberger-OSI GmbH & Co. OHG

Optical Solutions & Infrastructure | Endorferstr. 6 | 86167 Augsburg | GERMANY | Telefon: +49 821 24924-0

[email protected] | www.rosenberger.com/osi

Rosenberger® is a registered trademark of Rosenberger Hochfrequenztechnik GmbH & Co. KG. All rights reserved. © Rosenberger 2017

For technical reasons, we reserve us the right to make any deviations from the illustrations in the product information. Transfer to third party only by authority of Rosenberger-OSI GmbH & Co. OHG- All rights reserved

Creation date: 2015-08-11 Valid since: 2018-01-29 Revision: 005

About Rosenberger OSI: Since 1991, Rosenberger Optical Solutions & Infrastructure (Rosenberger OSI) has been an expert in innovative fiber optic cabling infrastructure and service solutions for Datacom, Tele-com and Industrial. The products and services can be found wherever largest amounts of data have to be trans-

ferred quickly and securely. In addition to the development and production of a broad portfolio

of fiber optic and copper cabling systems, Rosenberger OSI also offers a variety of services

such as planning, installation and maintenance of cabling infrastructure. Rosenberger OSI em-

ploys about 600 people in Europe and has been a part of the globally operating Rosenberger

Group since 1998, a worldwide leading provider of high-frequency, high-voltage, and fiber-

optic-connection solutions headquartered in Germany.

For further information, please visit: www.rosenberger.com/osi