Upload
praveen-bhairawadagi
View
61
Download
1
Embed Size (px)
Citation preview
RESUME
PRAVEEN M BHAIRAWADAGI
PROJECT DESIGN ENGINEER
B.E (MECHANICAL)
Email:[email protected]
Contact no: +91-9986437115
OBJECTIVE:-
To work in a firm with a professional work driven environment where I can utilize
and apply my knowledge, skills which would enable me to grow while fulfilling organizational
goals.
WORK EXPERIENCE:-
DESIGNATION: HVAC Design Engineer at “SNEHA ENTERPRISES & CHANNEL
PARTNER BLUE STAR”. Total Eight months experience in HVAC and still
working in same company.
Successfully completed low and high side following HVAC projects,
KPMG building, Sarjapura road, Kaikondrahalli, Bangalore
Kopper Kadai, Dairy circle, Koramangala, Bangalore
The Forum, Mall office, Koramangala, Bangalore
Brigade software park, Jayanagar 7th block, Bangalore
Co-ordinated with Prestige group, Biocon and Brigade projects for
complete our HVAC projects etc…
EDUCATIONAL QUALIFICATION:-
SL.
NO EDUCATION COLLEGE YEAR OF
PASSING
PERCENTAGE
%
1 SSLC Carmel High School 2009 86.40
2 2nd PUC Bangur Nagar Junior Composite
College, Dandeli 2011 77.67
3 B.E In Mechanical KLS VDRIT, Haliyal 2015 72.6
SOFTWARE SKILLS:-
KEY SKILLS:-
HVAC Designing
Heat load Estimation
Duct sizing & Designing
Pipe sizing & Designing
Air & Water Scheme drawing
Revit modeling & Calculations
Architecture modeling
Creation of spaces and zones
Heat load report
Duct sizing & designing
Pipe sizing & designing
Chiller plant design
Plumbing
Pressure drop report
Electrical work
Clash detection
Creation of family
BOQ
SOFTWARE DEVELOPER VERSION USED IN THE YEAR
AUTO CAD Auto Desk 2016 2015
REVIT Auto Desk 2014 2016
HAP Carrier v4.61 2015
Design Tool Duct Sizer Maquay v 6.4 2015
Psychometric Software Carrier v5.1.16 2015
BETA Software BETA Industrial LLC v 1.0.0 2015
Duct Checker Air Design .Inc. v 1.55 2015
VRF Piping Design Program Bluestar, Toshiba v 1.2 2015
Design tool Pipe sizer Maquay v 6.2 2015
MS word ,MS PowerPoint Microsoft 2007 2014
MEP PROJECT ACCOMPLISHED:-
Type : Office building
Location : Bangalore
Load calculation : 104.4 TR
Occupancy : 1008 People
Total area : 38014 SF
Architecture model:
Linked the given CAD file into REVIT project & then developed an architecture model.
HVAC Designing:
Creating spaces:
Created spaces within the room bounding element such as wall, roof & room separation
lines that exists in the architectural model.
Creating a space properties schedule:
Created working schedule of the building space properties and defined the different
Parameters to calculate the heat load. .
Performing heat load analysis:
Two trials of cooling loads are generated, first run is to get sensible and latent load,
second run is to get accurate cooling load by defining ADP.
Equipment selection:
After estimating the heat load report selected the equipment’s and it depends on the types
of air conditioning system.
Chiller : Water cooled screw chiller for 104 TR.
Pumps : Condenser pump, Evaporator pump.
AHU : Ceiling suspended horizontal discharge.
Duct design:
Based on the Air flow rate calculated the duct size by using the Equal friction method.
By maintaining constant pressure drop and recommended aspect ratio designed ducts
using McQuay duct size software.
As per the duct size and air flow rate prepared air scheme diagram then implemented
same in REVIT model.
Air distribution:
Selected the air terminal devices on the basis of noise criteria and throw.
Placed the air terminals on the false ceiling and these air terminals are connected to
the duct system through the flexible ducts.
Public health engineering:
Plumbing fixtures are mounted in the architecture model and sanitary piping is done by
maintaining 1% slope.
Fire protection system:
Designed firefighting system as per NBC recommendations. Selected the sprinklers and
effectively placed on the false ceiling to avoid the fire hazards.
Clash detection:
Found the clashes between the two systems or two elements by linking files and resolved clashes
by using REVIT Software.
Drawing:
Prepared the drawings for A/C equipment’s and accessories installation.
BOQ’S:
Bill of quantities of Duct, Duct fittings and Air terminals.
Bill of quantities of pipe, pipe fittings and plumbing fixtures.
Bill of quantities of lighting fixture, cable trays, and cable trays fittings.
SUMMARY:-
I have good knowledge on Revit with HVAC and MEP design.
PERSONAL DETAILS:-
Name : Praveen M Bhairawadagi
Father name : Mahadev S Bhairawadagi
Date of birth
Languages known
: 12-06-1993
: English, Hindi & Kannada
Nationality : Indian
Gender : Male
Leisure Activities
Permanent Address
: Playing Chess, Cricket and Badminton
: Praveen M Bhairawadagi
K. H. B Colony (Near Bus stand)
Haliyal, Uttara Kannada
Karnataka, Pin-581329
DECLARATION:-
I hereby declare that the above written particulars are true to the best of my knowledge.
Place: Bangalore
(PRAVEEN M BHAIRAWADAGI)