P P O O W W W P P R R E E V V E E N N T T I I O O N N i i s s b b e e t t t t e e r r a a n n d d c c h h e e a a p p e e r r t t T T r r u u s s t t t t h h e e e e x x p p e e r r t t s s ! ! ! ! PE-AORDF-1 Fully Automatic Oil Re tester is an integrated unit, consisti Measuring Bridge. The Stainless S mounted inside the HF Induction h is engaged to it automatically. Mea of AC/DC high voltage supply, T precision electronic bridges to m readings for Resistance Resistivity Capacitanc Power Facto Tan-Delta Watt-loss Dielectric Cons Temperatur Pre-programmed international test to ASTM-D924-04 ASTM-D1169 IEC-60247 IEC-61620 IS-6262/6103 NBR 12133 W W WE E R R E E L L E E C C T T R R O O O High Voltage Dielectric Diagnostics D-24, M Nasik – Tel : +91 Fax : +9 Email : t t h h a a n n C C U U R R E E PE Fully Automati Dissipatio Oil suffers from electr while a transformer there are contaminati interactions with w insulations, catalyze temperature. As a r properties of Transfo rendering it ineffectiv after extensive usage periodically tested to properties, and make use, or be able to a regeneration to be don Resistivity & Tan-Delta ing of Heater unit and Steel oil cell is to be heater cubicle, and HV asuring Bridge consists Tera-ohm meter, and measure & derive the e y ce or a s stant re t methods compliant VDE-0380-2 BS-5737 F Complete automat voltage is selected terminal Oil cell, displays and prints t High Accuracy, Best Programmable AC & Pure Sine test oper low ripple for DC me Heater interfaced w set, control and disp Multiple temperatu Facility for measuri Resistivity and Diele SF6 Gas Capacitor in Big color Touch-scr user convenience Integrated panel pri Pre-programmed 9 programmable 10 te USB2.0 interface for On-site calibration p Optional RS232 in Automated Laborat O O O N NI I C C A A L L MIDC Ambad, 422010, MH, India. 1 253 6602387 91 253 6602388 [email protected] E-AORDF-1 tic Oil Resistivity & on Factor Tester rical and mechanical stresses is in operation. In addition ions caused due to chemical windings and other solid ed by high operating result the original chemical ormer Oil changes gradually, ve for its intended purpose e. Hence this oil has to be ascertain its basic electrical sure it is suitable for further advise necessary filtration / ne. Features tic test procedure. Once test d, it applies excitation to the 3- measures R, C, DF, and then the results on integrated printer t resolution in its class & DC test voltages ration for AC measurements and easurements with main unit for temperature play ure set values programmable ing or inputting Cell Constant for ectric Constant ntegrated inside for std reference reen 7” TFT LCD with backlit for inter for immediate printing 9 test sequences, and user- est sequences r PC possible for yearly schedule nterface with PC software, for tory setup (LIMS)

PPOOWW EERR EELLEECCTTRROONNIICCAALLpowerelectronical.com/PDF/PE-AORDF-datasheet.pdf · IS-6262/6103 NBR 12133 EERR EELLEECCTTRROO High Voltage Dielectric Diagnostics D-24, MIDC Ambad,

  • Upload
    votuyen

  • View
    227

  • Download
    0

Embed Size (px)

Citation preview

PPPOOOWWW

PPRREEVVEENNTTIIOONN iiss bbeetttteerr aanndd cchheeaappeerr ttTTrruusstt tthhee eexxppeerrttss!!!!

PE-AORDF-1 Fully Automatic Oil Resistivity & Tantester is an integrated unit, consisting ofMeasuring Bridge. The Stainless Steel oil mounted inside the HF Induction heater cubicle, and HV is engaged to it automatically. Measuring Bridge consists of AC/DC high voltage supply, Teraprecision electronic bridges to measure & readings for

ResistanceResistivity

CapacitancePower Factor

Tan-DeltaWatt-loss

Dielectric ConstantTemperature

Pre-programmed international test methods compliant

to ASTM-D924-04 ASTM-D1169 IEC-60247 IEC-61620 IS-6262/6103 NBR 12133

WWWEEERRR EEELLLEEECCCTTTRRROOO High Voltage Dielectric Diagnostics

D-24, MIDC Ambad,Nasik – Tel : +91 253 6602387Fax : +91 253 6602388Email :

tthhaann CCUURREE

PEFully Automatic Oil Resistivity &

Dissipation Factor

Oil suffers from electrical and mechanical stresses while a transformer is in operation. In addition there are contaminationsinteractions with windings and other solid insulations, catalyzed by high operating temperature. As a result the original chemical properties of Transformer Oil changes gradually, rendering it ineffective for its iafter extensive usageperiodically tested to ascertain its basic electrical properties, and make sure it is suitable for further use, or be able to advise regeneration to be done.

1 Fully Automatic Oil Resistivity & Tan-Delta unit, consisting of Heater unit and

Stainless Steel oil cell is to be HF Induction heater cubicle, and HV

Measuring Bridge consists ly, Tera-ohm meter, and

measure & derive the

Resistance Resistivity apacitance

Power Factor Delta

loss Dielectric Constant

Temperature

international test methods compliant

VDE-0380-2 BS-5737

Features

Complete automatic test procedure. Once test voltage is selected, it applies excitation to the 3terminal Oil cell, measures R, C, DF, and then displays and prints the results on integrated printer

High Accuracy, Best resolution in its class Programmable AC & DC test voltages Pure Sine test operation for AC measurements and

low ripple for DC measurements Heater interfaced with main unit for temperature

set, control and display Multiple temperature set values programmable Facility for measuring or

Resistivity and Dielectric Constant SF6 Gas Capacitor integrated inside for std reference Big color Touch-screen

user convenience Integrated panel printer for immediate printing Pre-programmed 9 test

programmable 10 test sequences USB2.0 interface for PC On-site calibration possible for yearly schedule Optional RS232 interface with

Automated Laboratory setup

OOONNNIIICCCAAALLL

24, MIDC Ambad,

422010, MH, India. Tel : +91 253 6602387 Fax : +91 253 6602388 Email : [email protected]

PE-AORDF-1 Automatic Oil Resistivity &

Dissipation Factor Tester

Oil suffers from electrical and mechanical stresses while a transformer is in operation. In addition

are contaminations caused due to chemical interactions with windings and other solid

, catalyzed by high operating temperature. As a result the original chemical properties of Transformer Oil changes gradually, rendering it ineffective for its intended purpose

extensive usage. Hence this oil has to be periodically tested to ascertain its basic electrical properties, and make sure it is suitable for further

be able to advise necessary filtration / to be done.

Features

Complete automatic test procedure. Once test voltage is selected, it applies excitation to the 3-terminal Oil cell, measures R, C, DF, and then displays and prints the results on integrated printer High Accuracy, Best resolution in its class

ammable AC & DC test voltages Pure Sine test operation for AC measurements and

ripple for DC measurements Heater interfaced with main unit for temperature set, control and display Multiple temperature set values programmable Facility for measuring or inputting Cell Constant for Resistivity and Dielectric Constant SF6 Gas Capacitor integrated inside for std reference

screen 7” TFT LCD with backlit for

printer for immediate printing programmed 9 test sequences, and user-

programmable 10 test sequences USB2.0 interface for PC

site calibration possible for yearly schedule interface with PC software, for

Automated Laboratory setup (LIMS)

PPPOOOWWWEEERRR EEELLLEEECCCTTTRRROOONNNIIICCCAAALLL High Voltage Dielectric Diagnostics

D-24, MIDC Ambad, Nasik – 422010, MH, India. Tel : +91 253 6602387 Fax : +91 253 6602388 Email : [email protected]

PPRREEVVEENNTTIIOONN iiss bbeetttteerr aanndd cchheeaappeerr tthhaann CCUURREE TTrruusstt tthhee eexxppeerrttss!!!!

Operation The PE-AORDF-1 has been designed to be used in extreme atmospheric conditions and rough handling by experienced but unskilled persons. The user interface is either thro a touch panel graphical LCD, or thro the PC software. Parameters can be set on both sides, and display and printing of test results can too be done either side. The user has to either select from an array of pre-programmed test options including most international standards, or his own customized test sequence. He has to then load the Oil cell with Oil and put it in the heater compartment, connect the HV, LV and GND wires to the Oil test cell and the main equipment, and then press the Start Test button on the display. The user can then rest while the equipment controls the Heater to take it up to the programmed

elevated temperature and upon reaching that temperature, measures all the necessary readings. Exception is only in the case of measuring Dielectric Constant, whereby user has to first load a clean empty test cell, and then upon prompting by the equipment, reload it with an oil filled test cell. De-polarization is done automatically between AC and DC measurements to avoid faulty readings. The test results are then automatically stored in the internal memory with the unique ID that was allotted at the time of start of test. The synopsis of the test results is automatically printed on the integrated thermal printer. The user can anytime access the last 99 stored records on the internal non-volatile memory of AORDF-1 thro a PC, and print them on the local printer or store them for future reference

Safety User safety has been given paramount importance while designing, followed by instrument safety. Integrated interlocks have been designed to make sure that despite connection errors, the automatic systems prevent the user and instrument from any hazards. Important safety features that have been incorporated are

- Ground Open interlock. The set will not function ahead unless a proper Gnd is provided to the instrument - Different pin systems on test leads and terminals for Temp & LV connection, that cannot be mated together - Ultra fast blow fuse installed internally to avoid accidental short-circuit - High-Voltage suppressor and line filters integrated to avoid supply fluctuation and effect - Completely shielded test leads, tested with 1.5 times test voltage to avoid shock hazard to user - Automatic discharging of test object (Oil cell) after test completion to avoid residual charge impact on user - Heater incorporated with Fire retardant materials to restrict hazards

Specifications Input Power Supply – Single Phase 220V AC 50 Hz + 10% Input pin type – Round 3-pin (L, N, E). European, Australian, US pin types available on request Measuring Bridge VA – max 500VA Heater VA – max 500VA Heater Temperature Range – ambient to 110 deg C, resolution 0.1 deg C Temperature error – 0.5 deg C (max) Time to 100 deg C < 20 mins

PPPOOOWWWEEERRR EEELLLEEECCCTTTRRROOONNNIIICCCAAALLL High Voltage Dielectric Diagnostics

D-24, MIDC Ambad, Nasik – 422010, MH, India. Tel : +91 253 6602387 Fax : +91 253 6602388 Email : [email protected]

PPRREEVVEENNTTIIOONN iiss bbeetttteerr aanndd cchheeaappeerr tthhaann CCUURREE TTrruusstt tthhee eexxppeerrttss!!!!

Test Voltage

For Dielectric Constant – 60V to 2000V AC & Tan-Delta (in steps of 1V)

For DC Resistivity – 100V to 2000V DC (in steps of 1V)

Accuracy of Voltage setting – + (1% of set value + 10V)

Measured Parameters

Tan Delta range – 0 to 4 Tan Delta resolution – 0.000001 (10 -6)

Tan Delta Accuracy – 1 % of reading + 0.00005

Capacitance range – 15.0 pF to 1000 pF Capacitance resolution – 0.1 pF

Capacitance Accuracy – 0.1% of reading + 0.5pF Dielectric Constant range – 1 to 20 when using a typical test cell (C ~ 50-60pF) Dielectric Constant resolution – 0.001

Dielectric Constant Accuracy – + 0.1 %

Resistance Range – 1 MΩ to 10 TΩ (not calibrated above 10TΩ) Resistance Resolution – 4 digits

Resistance Accuracy – 5% of reading over entire range, 10% beyond 1TΩ

Resistivity Range – 500 MΩ cm to 10000 TΩ cm (for typ Cempty – 55pF) Resistivity Resolution – 4 digits

Resistivity Accuracy – 5% of reading over entire range, 10% for > 500TΩcm

Atmospheric Storage Temp – minus 20 deg C to +60 deg C Operating Temp – minus 10 deg C to +50 deg C

Humidity < 90% non-condensing

Physical Size – 200mm(H) × 375mm(W) × 450mm(D)

Gross Weight – 27kgs (incl accessories), except packing

PPPOOOWWWEEERRR EEELLLEEECCCTTTRRROOONNNIIICCCAAALLL High Voltage Dielectric Diagnostics

D-24, MIDC Ambad, Nasik – 422010, MH, India. Tel : +91 253 6602387 Fax : +91 253 6602388 Email : [email protected]

PPRREEVVEENNTTIIOONN iiss bbeetttteerr aanndd cchheeaappeerr tthhaann CCUURREE TTrruusstt tthhee eexxppeerrttss!!!!

Hipot AC/DC Testers up to 500kV Insulation Testers (10M to 15T, 2% accuracy) High Voltage Breakdown testers (10kV-50kV) SF6 Gas filled Standard Capacitors (upto 1000kV)

Standard Accessories

Test equipment – 1 no *

Heater unit – 1 no

Closed cup SS Oil cell – 1 no

Printer roll – 1 no (already loaded), plus 1 spare roll

Connecting AC mains cable – 1 no

Connection test leads – 1 set

User manual (Video CD) – 1 no

Test certificate – 1 no

Warranty Certificate – 1no (Standard warranty 1 yr)

* Default language is English. Spanish, French and Portuguese language options also available, but need to be defined before placing order. Note – Power Electronical reserves the right to change product specifications for continual improvement. Please order a fresh copy of specs from [email protected], before placing new orders. Jurisdiction limits within territory of Republic of India only.

Our other Products are – Automatic Cap & Tan Delta test system 10kV / 12kV Manual C&DF test system 12kV Automatic Oil Breakdown Voltage Tester 80kV / 100kV Motorised Oil BDV set 0-100kV