Powerware series
Eaton 9140 UPS
Features• Protectsmission-criticalrackmountapplicationsfromdowntime,
dataloss/corruption,andprocessinterruptionbyproviding continuous,cleanpowerwithdoubleconversiontopology
• Conservesvaluablerackspacewithupto10kVAofpowerinonly6Uofheight,includingbatteries
• Pre-installedrackmounthardwaresignificantlyreduces installationtime
• Modular,lightweightdesignfacilitatesinstallationandimprovesservicetime
• Upgradablefrom7.5kVAto10kVA,toaccommodate systemgrowth
• Blade-servercompatiblewithstandardIECreceptacles
• ABM®technologysignificantlyincreasesbatterylife,resultinginmoreuptimeandfewerbatteryreplacements
• Backedbyatwo-yearlimitedwarrantyand$250,000loadprotectionguarantee
Superiorde-centralizedpowerprotectionformedium-andhigh-densityrackenvironments
Product snapshot
Power rating: 10 kVA/8 kW and 7.5 kVA/6 kW Single-phase in/single-phase out Three-phase in/single-phase out (manually selectable in HW version)
Nominal input 1/1: 230 Vac (200–240 Vac) voltage: 3/1: 400/230 Vac
Nominal output 208 or 230 Vac auto-sensing voltage: (200–240 Vac)
Frequency: 50/60 Hz (auto-sensing)
Configuration: Double conversion 6U rackmount, including batteries
Dimensions: 10.5” H (6U) x 17” W x 31.1” D 263 mm x 430 mm x 790 mm
Today’sracksofITequipmentarerequiringevengreaterpower,fromcomputerroomsandwiringclosetstocommercialdata centers.WhetheryoumanagetheITneedsofasmall-to-mediumbusinessoranentirecommercialfacility,youknowitisachallengetoprovidein-rackpowerprotectionforexpandingloadsinshrinkingspaces.
Fortunately,technologyadvancementshavealsoraisedthepowerdensityofpowerprotectionsystems.TheEaton®9140UPSfromourPowerware®seriesdeliversefficient,reliablepowerprotectioninonly6Uofrackspace,includingbatteries.
ThisdoubleconversionUPSresolvesallninecommonutilitypowerproblemsandsuppliesclean,continuouspowertoallconnectedequipment.Ifutilitypowergoesoutaltogether,thereisnodelaytransferringtobackuppower,eithertoUPSbatteriesoranauxiliarygenerator.
2 EATON CORPORATION Eaton 9140 UPS
Optimize battery performanceStandardinternalbatteriesprovideride-throughpoweruntilauxiliarypowertakesoverorsystemsaregracefullyshutdown.At10kVA,youcanextendruntimeupto45minutesatfullloadwithextendedbatterymodules(EBMs).Lowerloadswillseeevengreaterruntimes.These3UrackmountunitsusethesamebatterymodulesasthosefoundinsidetheUPS,minimizinginventoryrequirements.
ABMtechnologysignificantlyextendsbatteryservicelifewhileoptimizingthebatteryrechargetimewithauniquethree-stagechargingtechnique.TheUPSautomaticallytestsbatteryhealthandprovidesadvancenotificationwhenpreventivemaintenanceisneeded.
Streamline operations with complete rackmount solutions from EatonAll9140modelsandcorrespondingEBMscomewithpre-installedrackmounthardwareforeasyinstallationinstandardequipmentracks.Also,all9140UPSsandEBMscomewithseismic-mountingkits.Shouldyourapplicationspecifyzone4seismicrequirements,allhardwareisincludedwiththeUPSandEBM.
Foreaseofoperationandlowesttotalcostofownership,youcancountonEatonforallyourrackmountpowerprotectionanddistributionneeds,inadditiontoUPSsandoptionalEBMs.
OurlineofrackmountEatonpowerdistributionunits(PDUs)distributesconditionedUPSpowerthroughoutoneormoreracks—simply,elegantlyandinexpensively.ThebasicPDUsofferstandardinputandoutputpowerconnections.EatonboastsmultiplePDUmodelsthatcanbeconnectedtotheoutputofthe9140,anddistribute200–240Vpowerthroughoutyourrack.
Additionally,smallstep-downtransformeroptionsdeliver120Voutputtopowercommunications,monitoringandotherperipheralequipment.Threeofour3kVAmodeloptionsoccupyonly2Uofrackspace;a250VAmodeloffersspace-saving1Uand0Umountingoptions.BothmodelsconnecttoUPSreceptaclesandhavestandardNEMAoutputs.
Stay continually informed of UPS statusForlocalmonitoring,UPSsinthisclassofferonlystatus indicators.The9140featuresbothLEDsandanintuitive,multilingualLCDonthefrontoftheunit.TheLCDrelaysmorein-depthoperationalinformation,communicatesspecificalarmsandpredictiveserviceneeds,andcanbeusedtoprogramcertainfeatures.
The9140constantlymonitorsitsownoperationandsendsalarmsortakesactionifitdetectsapotentialproblem.Ifitsensesanissue—plannedorunplanned—theUPSinstantlytransferstobatteryorbypasssource,andbacktonormalwhenthealarmconditionpasses,withnointerruptioninpower.
Easily install and service your UPSWiththe9140,Eatonintroducesanewstandardinsystemavailability.Thekeyisaninternalautomaticbypassfeaturethatallowsthe9140tocontinuouslyprovidepowertocriticalequipmentwhilethesystemisserviced—evenwhentheelectronicsareremoved.Amanualbypassswitchinthechassiseliminatestransfertimeandallowsformodulerepairandreplacementwithoutshuttingdowntheload.And,withEaton’scomprehensiverangeofmonitoring,remotediagnosticandfieldtechniciandispatchservices,wecanhelpexpeditemeantimetorepair(MTTR)shouldtheneedarise.
YouwanttoinstallandserviceyourUPSquicklyandefficiently.That’swhythe9140comeswithpre-installedrackmounthardware,andfeaturesmodulesthatareuser-replaceable.Oneperson,workingalone,canreplaceabatterymodulewithoutdisruptingdatacenteroperationsorpowertoprotectedequipment.Or,shouldyouneedtoreplaceyourpowermodule,thattoocanberemovedbyasingleperson.TheUPSautomaticallytransferstoandfrombypasswhenamoduleisremovedandinstalledtoprovideuninterruptedpowertotheload.
Intoday’sdynamicITenvironment,dataroomfootprintschangequickly.IfyoufindyourselffrequentlymovingracksandotherITequipment,perhapsa9140cordedUPSisforyou.ThisversionofourUPSisequippedwithastandardIEC309-60Acordwithplugasinput,whichmeansyoudon’tneedanelectriciantoinstallyourUPSwitheachmove—offeringyougreaterflexibility.
Introducing the 9140
The 9140 and one EBM occupy only 9U of rack space.
9140 runtimes (in minutes)
UPS Internal +1 +2 +3 +4 VA Watts Batteries EBM EBMs EBMs EBMs
1250 1000 80 137 189 275 3652500 2000 31 61 99 138 1813750 3000 18 38 68 92 1215000 4000 12 27 52 69 906250 5000 9 21 42 55 727500 6000 7 17 35 46 608750 7000 6 14 31 40 5110,000 8000 5 12 27 35 45
3
Modular, lightweight design allows for easy installation and service.
Monitor the UPS from any-where.ConnecttheUPStotheEthernetnetworkandInternetforsecuremonitoringandman-agementusingastandardWebbrowserorSNMP.
Interwork with your exist-ing Building Management System.AModbus®Cardenablesreal-timemonitoringofUPSsystemsthroughabuild-ingmanagementsystemorindustrialautomationsystem.
Gather information from relay contact devices. Providesadry-contactinterfacebetweentheUPSandanyrelay-connecteddevice,includ-ingtheIBM®eServer® iSeries andavarietyofindustrialappli-cations.
Monitor environmental conditions.AnoptionalEnvironmentalMonitoringProberemotelymonitorstem-perature,humidityandtwouser-suppliedcontacts/sensors,suchassmokeandintrusiondetection.
Unify and centralize UPS managementEvery9140comeswithLanSafe®powermanagementsoftwarethatenablesyoutoremotelymonitorUPSandbatteryperformance,establishprioritizedshutdownofdevicesandapplications,testallnetworkedUPSs,analyzetrendsandnetworkconditions,andstayinformedwithapagerande-mail.
Connectivityiseasy.Thestandardunit9140comeswithaUSBport,aserialport,andanX-Slot®bayforadditionalcommunicationoptions.WithX-Slotinterfacecards,theUPScancommunicateinavarietyofnetworkingenvironments,includingtheWeb,aswellasbuildingmanagementsystems,environmentalmonitors,relaycontactdevices,multipleserversandotherUPSs.
Gain a new level of confidenceBackedbyacomprehensivewarrantyprogram,the9140deliversreliable,efficientandfull-featuredprotectionavailableforyour organization’scriticalelectronics.
RackmountUPSsfromEatondeliverconfidence—confidencethatyourrackenvironmentsareservedbycompletepowerconditioningandbatterybackup,andconfidencethatEatonwillbewithyouforthelongtermwithpremiumwarrantycoverageandexperttechnicalsupport.
To
standardunitisequippedwithUSBandRS-232serial portstocommunicatewithpowermanagementsoftware.YoucancustomizeyourUPSbyaddinganinterfacecardforotherapplications:
4 EATON CORPORATION Eaton 9140 UPS
9140 products and services
Part Input Output Dimensions Weight Model number connection connections (H x W x D, inches) (lb)
200–240 Vac in (single-phase)/200–240 Vac out User selectable 380–415 Vac in (three-phase)/220–240 Vac out (single-phase) for hardwire modelsPW91407500HW 103005093-6591 Hardwired Hardwired(3)C19&(2)C13 10.5(6U)x17.2x31.1 254PW914010000HW 103004728-6591 Hardwired Hardwired(3)C19&(2)C13 10.5(6U)x17.2x31.1 254PW91407500 103005094-6591 IEC309-60Acord IEC309-60Acord,(4)C19 10.5(6U)x17.2x31.1 265PW914010000 103004727-6591 IEC309-60Acord IEC309-60Acord,(4)C19 10.5(6U)x17.2x31.1 265 9140 Extended Battery Modules
PW91403UEBM1 103004729-6591 5.25(3U)x17.2x26.0 175
1. Up to four EBMs can be connected to a single 9140
PowerPass® Distribution Modules (PPDM)
3000 VA 208–240 Vac in – 120 Vac out
PDM1-HV-US-P1 103002742-6501 IEC320-C20 (1)L14-30R&(6)5-20R 3.5(2U)x17.0x23.9 50PDM1-HV-US-P2 103002730-6501 IEC320-C20 (1)L5-30R&(6)5-20R 3.5(2U)x17.0x23.9 50PDM1-HV-US-P3 103002731-6501 IEC320-C20 (6)5-20R 3.5(2U)x17.0x23.9 50 250 VA 208–240 Vac In – 120 Vac out
250VAPPDM 05146401-6501 IEC320-C13 (2)5-15R 0Uformfactor, 19 sidecabinetmount
Power distribution units (PDUs)
PDU1212C 103004548-6501 IEC320-C14 (12)C13 1.75x17.5x4.0 5.3PDU1610C 103004550-6501 IEC320-C20 (2)C19,(8)C13 1.75x17.5x4.0 5.8PDU3208C 103004552-6501 Hardwired (1)C19,(3)C13, 1.75x17.5x4.0 4.3 (1)C19,(3)C13PDU1210N 103004538-6501 5-15P (10)5-15R 1.75x17.5x4.0 4.8 (forusewithPPDM)PDU2408N 103004546-6501 L5-30P (4)5-20R,(4)5-20R 1.75x17.5x4.0 6.8 (forusewithPPDM)PDU2408N3 103004551-6501 L14-30P (2)L6-30R,(2)L5-20R, 3.5x17.5x4.0 9.8 (forusewithPPDM) (4)5-20RCordretentionbracket 103004542-6501
Enclosures
Product Shipping dimensions dimensions Weight Part number Description (H x W x D, inches) (H x W x D, inches) (lb)
9970936 42UEnclosuresplitrear&sides 80x24x42 83x32x48 2959970935 42UExtensionsplitrearnosides 80x24x42 83x32x48 2579970940 42UEnclosuresplitrear&sides&casters 80x24x42 85x32x48 3059970939 42UExtensionsplitrear&castersnosides 80x24x42 85x32x48 267 9140 connectivity options
Part number Description
103002974-5501 ConnectUPS-XWeb/SNMPcard103002510-5501 Modbuscard1018460 Relaycard(AS/400compatible)103003055 Industrialrelaycard103003637-5501 EnvironmentalMonitoringProbe(EMP)(requiresConnectUPSWeb/SNMPX-Slotcard)
5
Input terminal block
REPO connector
USB port
X-Slot communication bay
(4) 20A/250V output circuit breakers
(3) C19 output receptacles
EBM connector
Output terminal block cover
Serial port
(2) C13 output receptacles
Bypass input
9140 hardwire9140 EBM (rear view)9140 (rear view)
EBM battery connectorCircuit breaker
9140 technical specificationsPowerRatings 10kVA/8kWfor208–240Vnominalvoltage
9kVA/7.2kWfor200V 7.5kVA/6kW
Topology Truedouble-conversionUPS
Electrical input
Nominal input voltageSingle-phase 200–208V(for200–208Vnominaloutput);
220–240VThree-phase 380/220V,400/230V,415/240V
Input voltage rangeSingle-phase 160–253V(for200–208Vnominaloutput);
174–288V(for220–240Vnominaloutput)Three-phase 301–499V/174–288VOperatingfrequency 45–55Hzrangefor50Hznominal;
55–65Hzrangefor60HznominalInputpowerfactor >0.99Inputcurrentdistortion <5%THD
Electrical outputSingle-phase 200V/208V/220V/230V/240Vuser-selectableOutputvoltageregulation ±2%static,±10%dynamicEfficiency >90%Outputfrequency Automaticselectionof50Hznominal
(±3.5Hz)and60Hznominal(±3.5Hz)Batterytype 12V,5Ah,sealed,lead-acid,maintenance-
freeBatteryruntime SeebatteryruntimechartBatteryreplacement Modular,hot-swappable,user-replaceableCharger 2.5Achargertosupportuptofour
additionalEBMsStart-on-battery AllowsstartupofUPSwithoututilityinput
CommunicationsLCD MultilingualgraphicalLCDwithbacklightLEDs (4)LEDsfornoticeandalarmCommunicationports (1)USB,(1)RS-232serial,(1)REPOCommunicationslot (1)X-Slotcommunicationbay
Powermanagement software
BundledsoftwaresuiteCD 9140isHID-compliant
GeneralDimensions H x W x D, in/mmPW9140UPS 10.5(6U)x17x31.1/263x430x790PW9140EBM 5.25(3U)x17x26/131x430x660WeightPW9140UPS 254lbPW9140EBM 175lbBatterymodule 37lbPowermodule 40lbUPSbypass Automaticonoverload,overtemp,UPS
failureorremovalofpowermoduleOverloadtobypass ±10%of112to130%for60seconds,
transfer
EnvironmentalRoHScompliance EURoHS/WEEEcompliantOperatingtemperature 0°Cto40°C(32°Fto104°F)Transitandstorage temperature
-20°Cto+50°C(-4°Fto122°F)
Relativehumidity 0–95%non-condensingAudiblenoise <55dBAat5feet
Altitude Operating3000m,transit15000m
CertificationsSafetycertifications UL,cULus,NOM,TUV,CEEMCcompliancemarkings FCC,CE,VCCI,C-Tick
powerware, powerChain Management, ABM, LanSafe, powerpass and X-Slot are trade names, trademarks, and/or service marks of Eaton Corporation or its subsidiaries and affiliates. All other trademarks are the property of their respective owners.
©2009 Eaton CorporationAll Rights Reservedprinted in USA9140FXAOctober 2009