13
Power System Engineering Want to own your Customer’s Power System?

Power System Engineering Want to own your Customer’s Power System?

Embed Size (px)

Citation preview

Page 1: Power System Engineering Want to own your Customer’s Power System?

Power System Engineering

Want to own your Customer’s Power System?

Page 2: Power System Engineering Want to own your Customer’s Power System?

Schneider Electric 2- Engineering Services – January 2009

PSE Helps You Own the Power System – Then What?

●LEVERAGE● EVERY $1 in PSE that you sell equates to $8 in Pull-Through

Products/Services

●Customers come to you without BIDDING!● 75% of the PSE pull-through comes without hitting the street

●Your Solutions Provider reputation increases!● PSE takes the system view, with customer economic benefit as primary

driver

Page 3: Power System Engineering Want to own your Customer’s Power System?

Schneider Electric 3- Engineering Services – January 2009

What sets PSE above the competition?

●Credentials● Engineers recognized as Industry Experts

● Local and National IEEE Leadership & Knowledge

● Registered Professional Engineers, Licensed Engineering Firm

●Experience and Expertise● Square D has been doing studies since 1966

● History since 1998: 7000+ studies, 750+ assessments/turnkey projects

● Innovative analysis tools & methodologies, applied consistently across US

●Regional Locations● Regional PSE Engineers deployed strategically across US – all time zones

● Knowledge of local markets, codes, and AHJs

Page 4: Power System Engineering Want to own your Customer’s Power System?

Schneider Electric 4- Engineering Services – January 2009

Power System AssessmentsShort Circuit StudiesOvercurrent Coordination StudiesArc Flash StudiesLoad Flow, Circuit Capacity StudiesGrounding and Ground Fault AnalysisPower Quality TroubleshootingPower Factor and Harmonics AnalysisOnsite Testing & Data CollectionMotor Starting StudiesConsulting, Analysis and Design

DERIVED>CURRENTC-AMPS(02-03-97)(14:59:23)

0 100000 200000 300000 400000-4000

-2000

0

2000

4000

6000

Time (mS)

Cu

rre

nt

(A)

DERIVED>CURRENTB-AMPS(02-03-97)(14:59:23)

0 100000 200000 300000 400000-6000

-4000

-2000

0

2000

4000

Time (mS)

Cu

rre

nt

(A)

DERIVED>CURRENT-A-AMPS(02-03-97)(14:59:23)

0 100000 200000 300000 400000-4000

-3000

-2000

-1000

0

1000

2000

3000

4000

Time (mS)

Cu

rre

nt

(A)

ASHEVI~1>CA_VOLTS-VOLTS(02-03-97)(14:59:23)

0 100000 200000 300000 400000-1000

-750

-500

-250

0

250

500

750

1000

Time (mS)

Volt

age

(V

)

ASHEVI~1>BC_VOLTS-VOLTS(02-03-97)(14:59:23)

0 100000 200000 300000 400000-1000

-750

-500

-250

0

250

500

750

1000

Time (mS)

Volt

age

(V

)

ASHEVI~1>AB_VOLTS-VOLTS(02-03-97)(14:59:23)

0 100000 200000 300000 400000-1000

-750

-500

-250

0

250

500

750

1000

Time (mS)

Volt

age

(V

)

MSBNorthMain

R2ThermalOx1

R2MCC

PPM

R2ThermalOX2

PanelLP

R2Coater

0.5 1 10 100 1K 10K0.01

0.10

1

10

100

1000

CURRENT IN AMPERES

MainNorth.tcc Ref. Voltage: 480 Current Scale X 10^1

TIM

E IN

SE

CO

ND

S

Power System Engineering Offers

Power System Studies & Analysis

Power System Onsite Assessments & Troubleshooting

Power System Improvement

Projects

Page 5: Power System Engineering Want to own your Customer’s Power System?

Schneider Electric 5- Engineering Services – January 2009

Power System EngineersPower System Engineers

40

Power System Engineering Team

Credentials● Registered Professional

Engineers, Licensed Engineering Firm

● Performed thousands of power system studies

● Backgrounds include EE, ME; many advanced degrees

● Industry recognized professionals who have authored many technical articles

● Present and past leaders of various IEEE, IEC, ANSI, NEMA & UL committees and working groups

Page 6: Power System Engineering Want to own your Customer’s Power System?

Schneider Electric 6- Engineering Services – January 2009

“We Want to Comply with NFPA 70E”

Arc Flash Deliverable Customer Benefit

Single-Line Electrical Drawings Lockout/Tagout, Troubleshooting

System & Equipment Assessment Identification of Reliability, Code Concerns

Short-Circuit Analysis Identification of Under-rated Equipment

Time-Current Coordination Optimal Settings for Overcurrent Devices

Arc Flash Analysis Reduced Arc Flash Exposure, PPE, Labels

Corrective Action Recommendations Prioritized System Improvement Projects

Page 7: Power System Engineering Want to own your Customer’s Power System?

Schneider Electric 7- Engineering Services – January 2009

New NFPA 70E-2009 Released

●NFPA Standards Council issued 70E-2009 in July 2008, not widely available until late 2008

●Maintains ‘mandatory’ language of a consensus standard●Represents results of over 500 proposals, 800 comments on previous

70E-2004 version●Many wording changes throughout document; described as ‘same

intent’, but changed for clarity

●PSE processes, methodologies, reports, labels, fully compliant with new version

2009 – Now’s the Time!

Page 8: Power System Engineering Want to own your Customer’s Power System?

Schneider Electric 8- Engineering Services – January 2009

Key Changes to NFPA 70E-2009

● Category 0/1 threshold– now 1.2 cal/cm2 vs former 2.0 cal/cm2

●Ear plugs at all categories, not just >Category 2

● Analysis cut-off point changed - was <240V and <10kA; now 240V or less served by single transformer <125 kVA

● Labeling now requires PPE category or incident energy level

●Analysis to be updated at time of renovation and reviewed periodically not to exceed every 5 years

● Emphasis on maintenance and testing● Emphasis on equipment integrity – ‘exposure

to electrical hazard’ vs ‘working on or near exposed parts’

Page 9: Power System Engineering Want to own your Customer’s Power System?

Schneider Electric 9- Engineering Services – January 2009

Construction Studies – Value!

●Verify equipment ratings● Short-circuit analysis results

●Value engineer project● Head off project problems due to unusual or less optimal designs

●Identify protective coordination issues● Ensure selectivity

●NEC Article 700/701 support (e.g. – Healthcare Projects)● Get the right BOM to satisfy special coordination requirements

●Arc flash analysis● Calculate exposure levels, identify arc flash mitigation opportunities

Use Our Updated Specs!Sales & Marketing home page, then Services, Power System Engineering

Page 10: Power System Engineering Want to own your Customer’s Power System?

Schneider Electric 10- Engineering Services – January 2009

2009 Key Offers

●Arc flash compliance – 2009, Now’s the Time!● PSE methodologies already updated to 70E-2009 standards● Customers should update old studies

●To 2009 standards●If renovations have been made, or if study >5 yrs old

● Arc-flash reduction techniques can reduce exposure

●Construction studies – Value-based and customer focused● Have you tried Square D – lately?

●Healthcare Risk Assessments● ID power system deficiencies, prioritize improvements

●Power System Improvement Projects● Help customer optimize scarce refurbishment dollars

●Power Quality Testing and Troubleshooting● Don’t let power problems fester, call the experts

Page 11: Power System Engineering Want to own your Customer’s Power System?

Schneider Electric 11- Engineering Services – January 2009

Whom to Contact?

●PSE / Regional Engineer●Principal Engineer●Eddie Jones / Janet Powell

Page 12: Power System Engineering Want to own your Customer’s Power System?

Schneider Electric 12- Engineering Services – January 2009

PSE Information●Now have Intranet area●White Papers, Specifications, How to Sell, Regional Line Card

Page 13: Power System Engineering Want to own your Customer’s Power System?

Schneider Electric 13- Engineering Services – January 2009

PSE Information

●External webpages