2011-‘12WROCLAW UNIVERSITY OF TECHNOLOGYFACULTY OF ELECTRICAL ENGINEERINGPresented by:Indrajeet PrasadContent:• • • • • • • • • • WHAT IS POWER QUALITY PQ PROBLEMS DESCRIPTION OF PQ PROBLEMS SOURCES OF PQ PROBLEMS MAJOR PQ PROBLEMS HOW THEY AFFECT HOW TO MONITOR BENEFITS OF PQ MONITORING CONCLUSION REFERENCEWHAT IS POWER QUALITY ?The term Power quality is used to describe the extent of variation of the voltage, current and frequency on the power system. The variation of voltage and current can either be in terms of m
Citation preview
YtvâÄàç Éy XÄxvàÜ|vtÄ cÉãxÜ XÇz|ÇxxÜ|ÇzYtvâÄàç Éy XÄxvàÜ|vtÄ cÉãxÜ XÇz|ÇxxÜ|ÇzYtvâÄàç Éy XÄxvàÜ|vtÄ cÉãxÜ XÇz|ÇxxÜ|ÇzYtvâÄàç Éy XÄxvàÜ|vtÄ cÉãxÜ XÇz|ÇxxÜ|Çz
Presented by:
IndrajeetIndrajeetIndrajeetIndrajeet PrasadPrasadPrasadPrasad
Content:
• WHAT IS POWER QUALITY
• PQ PROBLEMS
• DESCRIPTION OF PQ PROBLEMS
• SOURCES OF PQ PROBLEMS• SOURCES OF PQ PROBLEMS
• MAJOR PQ PROBLEMS
• HOW THEY AFFECT
• HOW TO MONITOR
• BENEFITS OF PQ MONITORING
• CONCLUSION
• REFERENCE
WHAT IS POWER QUALITY ?
The term Power quality is used to describe the extent ofvariation of the voltage, current and frequency on thepower system. The variation of voltage and current caneither be in terms of magnitude or waveformshape/distortion.shape/distortion.
WHAT IS POWER QUALITY MONITORING ?
The best way to detect and diagnose the problems inelectrical power system is called Power qualitymonitoring.
POWER QUALITY PROBLEMS:
• 1.Disturbance
I. Voltage sag
II. Voltage interruption
III. Voltage swellIII. Voltage swell
IV. Transient
V. Voltage notch
• 2.Imbalance
• 3.Distortion
• 4.Voltage fluctuation
• 5.Voltage flickering
DESCRIPTION:
• 1.DISTURBANCES
A DISTURBANCE IS DEFINED AS THE TEMPORARY DEVIATION
FROM THE STEADY STATE WAVEFORM.FROM THE STEADY STATE WAVEFORM.
• VOLTAGE SAG
Reduction in voltage magnitude for a short period of time.
• VOLTAGE INTERRUPTION
Voltage sag with 100% reduction in amplitude.
• VOLTAGE SWELL
Increase in RMS voltage or current at the power frequency between 1.1
to 1.9 per unit for a duration of 8milisec to 1min.
• TRANSIENT
Voltage disturbance shorter than sag/swell and are caused by sudden
changes in power system.
• VOLTAGE NOTCH
Periodic transient occurring within each cycle.
• 2.IMBALANCE
A SITUATION IN WHICH VOLTAGE,FREQUENCY AND PHASE ALL ARE DIFFERENT.
• 3. DISTORTION
IT IS GENERALLY EXPRESSED IN TERMS OF HARMONICS WHICH ARE SINUSOIDAL IT IS GENERALLY EXPRESSED IN TERMS OF HARMONICS WHICH ARE SINUSOIDAL
VOLTAGES OR CURRENTS HAVING FREQUENCY THAT ARE INTEGER MULTIPLE OF THE
FREQUENCY AT WHICH THE SUPPLY SYSTEM IS DESIGNED TO OPERATE.
• 4.VOLTAGE FLUCTUATION
THE RAPID CHANGE IN VOLTAGE MAGNITUDE IN THE ALLOWABLE LIMIT I.E., 95% TO 105%.
• 5.VOLTAGE FLICKERING
THE COLOUR OCCURING WHEN THE FREQUENCY OF VARIATION OF LIGHT FLUX LIES
BETWEEN FEW HERTZ AND FUSION FREQUENCY.
PQ is a Business Problem:
Power Quality issues cause business problems
such as:
– Lost productivity, idle people and equipment
– Lost orders, good will, customers and profits
– Lost transactions and orders not being processed
– Revenue and accounting problems
– Customer and/or management dissatisfaction
– Overtime required to make up for lost work time
TvvÉÜw|Çz àÉ XÄxvàÜ|v _|z{à tÇw cÉãxÜ `tzté|Çx? FC àÉ GC cxÜvxÇà Éy TÄÄ Uâá|Çxáá TvvÉÜw|Çz àÉ XÄxvàÜ|v _|z{à tÇw cÉãxÜ `tzté|Çx? FC àÉ GC cxÜvxÇà Éy TÄÄ Uâá|Çxáá TvvÉÜw|Çz àÉ XÄxvàÜ|v _|z{à tÇw cÉãxÜ `tzté|Çx? FC àÉ GC cxÜvxÇà Éy TÄÄ Uâá|Çxáá TvvÉÜw|Çz àÉ XÄxvàÜ|v _|z{à tÇw cÉãxÜ `tzté|Çx? FC àÉ GC cxÜvxÇà Éy TÄÄ Uâá|Çxáá WÉãÇà|Åx \á exÄtàxw àÉ cÉãxÜ dâtÄ|àç cÜÉuÄxÅáAWÉãÇà|Åx \á exÄtàxw àÉ cÉãxÜ dâtÄ|àç cÜÉuÄxÅáAWÉãÇà|Åx \á exÄtàxw àÉ cÉãxÜ dâtÄ|àç cÜÉuÄxÅáAWÉãÇà|Åx \á exÄtàxw àÉ cÉãxÜ dâtÄ|àç cÜÉuÄxÅáA
PQ Problems are Expensive
– Berkeley Lab Study Estimates $80 Billion Annual Cost of Power Interruptions … Research News, Berkeley Lab, February 2, 2005
– $50 billon per year in the USA is lost as a results of power quality breakdowns …. Bank of America Report
– A manufacturing company lost more than $3 million one day last summer in Silicon Valley when the “lights went out.” … New York Times January 2000
– “A voltage sag in a paper mill can waste a whole day of production - $250,000 loss” … Business Week, June 17,, 1996
– Half of all computer problems and one-third of all data loss can be traced back to the power line … Contingency Planning Research, LAN Times
Who is Affected?
• High Cost Facilities
o Semiconductor plants
o Pharmaceuticals
o Data centerso Data centers
• Medium Cost Facilities
o Automotive manufacturing
o Glass plants
o Plastics & Chemicals
o Textiles
Sources of PQ Problems:
Utility Sources
– Lightning
– PF Correction Equipment
– Faults
Internal Sources
• Individual Loads –Lighting, Elevators, Coolers, HVAC
• Uninterruptible Power Supplies – Faults
– Switching • Variable Frequency Drives
• Battery Chargers
• Large Motors During Startup
• Electronic Dimming Systems
• Lighting Ballasts (esp. Electronic)
• Arc Welders, and Other Arc Devices
• Medical Equipment, e.g. MRIs and X-Ray Machines
• Office Equipment and Computers
• Wiring
Major PQ Problems:
Spikes, 7%
Outages, 6%
Sags, 56%Swells, 31%
Swells
System fault conditions
Switching on a large capacitor bank
Switching off a large load
Sags (Dips)
Associated with system faults
Switching of heavy loads
Starting of large motors
HOW DO THEY AFFECT YOU:
• Motors stall
• Computers crash
• Production is affected
• Equipment damaged• Equipment damaged
• Product spoilage
• ‘The lights go out’
How To Monitor:
POWER QUALITY PROBLEM SOLUTION
VOLTAGE SAG UPS,DVR,CVT
VOLTAGE INTERRUPTION UPS
VOLTAGE SWELL UPS,POWER CONDITIONERVOLTAGE SWELL UPS,POWER CONDITIONER
TRANSIENT SVC
VOLTAGE NOTCH SNUBBER CKT
IMBALANCE PROTECTION SCHEME
DISTORTION SERIES & SHUNT ACTIVE FILTER
VOLTAGE FLUCTUATION SVC
VOLTAGE FLICKERING VOLTAGE UNBALANCED RELAY
BENEFITS OF POWER QUALITY MONITORING:
Direct Benefits / Technical Benefits• – Energy Savings
• – Release of blocked capacity
• – Reduced temperature rise• – Reduced temperature rise
• – Increased reliability / Life of equipment (e.g. Transformer, Motors, capacitors...)
• – Reduced mal-function of equipment (e.g. Drives, Relays, Meters)
Indirect / Regulatory Benefits• – Penalty savings / Incentives (e.g. Demand charges)
• – Tax benefits
• – Compliance to standards & Regulations
Conclusion:
• DISTURBANCES PLACE ALL BUSINESSES AT RISK BOTH
IN TERMS OF FINANCIAL LOSSES AND ENERGY
EFFICIENCY SO THEY SHOULD BE TAKEN SERIOUSLY.EFFICIENCY SO THEY SHOULD BE TAKEN SERIOUSLY.
• POWER QUALITY MONITORING IS VERY ESSENTIAL TO
GET AN UNINTERRUPTABLE AND EFFICIENT POWER
SUPPLY.
References:
• UNDERSTANDING POWER QUALITY PROBLEMS – VOLTAGE SAGS &INTERRUPTIONS, MATH H J BOLLEN, IEEE PRESS.
• AN INTEGRATED APPROACH TO POWER QUALITY IMPROVEMENT, R VENKATESH & S R KANNAN, - ET POWER TECH .VENKATESH & S R KANNAN, - ET POWER TECH .
• SOLUTIONS TO THE POWER QUALITY PROBLEM, PROF. RAY ARNOLD,IEE POWER ENGINEERING JOURNAL, APRIL 2001
• POWER QUALITY ISSUES A DISTRIBUTION COMPANY PERSPECTIVE,IEE POWER ENGINEERING JOURNAL, APRIL 2001
• MONITORING POWER FOR THE FUTURE, AFROZ K. KHAN, IEEPOWER ENGINEERING JOURNAL, APRIL 2001