Luminato Power Supply Manual, rev0012 Contents i
Power Module
Installation Manual
Lum
Luminato Power Supply LPS-BX-X, LPS-CX-X, LPS-EX-X, LPS-DX-X,
LPS-GX-X, LPS-FX-X Installation Manual
Luminato Power Supply Manual, rev0012 Contents ii
Contents
Contents ii
Introduction 1
General ................................................................................................. 1 Grounding ............................................................................................. 1 Caution! Invisible laser radiation ........................................................... 1
Installation 2
Power Supply LPS-EX-X ...................................................................... 2 Mechanical installation .......................................................................... 2
Connectors ........................................................................................... 3 Power Supply LPS-DX-X ...................................................................... 4 Mechanical installation .......................................................................... 4
Connectors ........................................................................................... 5 Backup Power Supply LPS-GX-X ......................................................... 6
Mechanical installation .......................................................................... 6 Connectors ........................................................................................... 7 Backup Power Supply LPS-FX-X .......................................................... 8 Mechanical installation .......................................................................... 8 Connectors ........................................................................................... 9
Backup power wiring ..................................................................................... 10 Backup Power Supply module LPS-GX-X or LPS-FX-X installed in a mounting frame ................................................................................... 10 Backup Power Supply module LPS-GX-X or LPS-FX-X installed in a Luminato chassis ................................................................................ 10
Mounting frame LCH-C-X-XXXX ......................................................... 12 Mechanical installation ........................................................................ 12
Environmental 13
WEEE Notice ................................................................................................. 13
European Conformity ..................................................................................... 13
Legal Declarations 14
Copyright Acknowledgements ....................................................................... 14
Luminato Power Supply Manual, rev0012 Introduction 1
Introduction
LPS-BX-X/LPS-EX-X (230VAC) and LPS-DX-X (-48VDC) are the power supply modules for the Luminato chassis. They are using primary switching mode technology providing high efficiency and reliability. LPS-BX-X/LPS-EX-X module is short circuit and over temperature protected and includes a PFC (Power Factor Correction). LPS-DX-X is protected against short circuit, reverse polarity and over temperature.
The specified output voltages and currents per circuit are 24V / 5.0A. Voltage is connected to the system via the Luminato chassis, so no connection cables are needed.
The power supplies have electrical screening of class 1 and they are intended for an indoor installation in a dry place. The units must not be installed in a place where they can be exposed to dripping or splashing water. The operating voltage is 110…240 VAC, 50-60 Hz for LPS-BX-X/LPS-EX-X, and -40...-70 VDC for LPS-DX-X.
Ensure that the Luminato is properly connected to the earth in order to meet safety requirements. Proper grounding will also improve the protection from the effects of interference and increase the overall reliability of the system. Ground the Luminato chassis using the grounding screw located near the main power connector. This unit may employ SFP module, which has a laser component. Due to the invisible laser radiation all necessary safety instructions must be followed during the installation and maintenance operations. In a properly closed system the normal operation of these components does not cause any radiation danger. The safety requirements for class 1M laser are detailed in EN60825.
General
Grounding
Caution! Invisible laser radiation
Luminato Power Supply Manual, rev0012 Installation 2
Installation
Power Supply LPS-BX-X/LPS-EX-X
Mount (slide) the power supply module LPS-BX-X/LPS-EX-X into the most right-hand module slot of the Luminato chassis (back view).
Note! Pay attention to the protection cover of the module when inserting (or removing) the power module. Under some circumstances it can get stuck to the Luminato chassis (modules manufactured before year 2011).
Tight the attachments screws (1) by hand and lock the module into place by attaching the locking screw (2) using screw driver.
Note! Ensure that the Luminato is properly connected to the earth in order to meet safety requirements. Proper grounding will also improve the protection from the effects of interference and increase the overall reliability of the system. Ground the Luminato chassis using the grounding screw (3).
Mechanical installation
Luminato Power Supply Manual, rev0012 Installation 3
1. GE 1 and GE 2 – gigabit Ethernet SFP module slots for payload streaming in and out.
2. USB – USB interface for initial setup. 3. EXT1 and EXT2 – General purpose I/O (not in use yet)
4. DC IN – 24VDC input (polarity protected) for external
redundant power supply 5. MGMT 1 and MGMT 2 – 100BaseT interfaces for
management. 6. Main power - Connect with a main cable to a grounded 100
- 240 VAC 50/60 Hz power outlet.
Connectors
Luminato Power Supply Manual, rev0012 Installation 4
Power Supply LPS-DX-X
Mount (slide) the power supply module LPS-DX-X into the most right-hand module slot of the Luminato chassis (back view).
Tight the attachments screws (1) by hand and lock the module into place by attaching the locking screw (2) using screw driver.
Note! Ensure that the Luminato is properly connected to the earth in order to meet safety requirements. Proper grounding will also improve the protection from the effects of interference and increase the overall reliability of the system. Ground the Luminato chassis using the grounding screw (3).
Mechanical installation
Luminato Power Supply Manual, rev0012 Installation 5
1. GE 1 and GE 2 – gigabit Ethernet SFP module slots for payload streaming in and out.
2. USB – USB interface for initial setup. 3. EXT1 and EXT2 – General purpose I/O (not in use yet)
4. DC IN – 24VDC input (polarity protected) for external
redundant power supply
5. DC input LED – shows that the DC input is valid (green), invalid (red) or not present (blank).
6. MGMT 1 and MGMT 2 – 100BaseT interfaces for
management. 7. Main power - Connect with HDP001 cable to -48VDC power
supply.
Connectors
Luminato Power Supply Manual, rev0012 Installation 6
Backup Power Supply LPS-CX-X/LPS-GX-X Luminato uses external backup power for securing main power supply located in chassis. Backup Power is connected to the DC IN connector in the main power supply LPS-BX-X/LPS-EX-X or LPS-DX-X. Its internal switching circuit automatically takes power from external power supply, if main power supply fails.
Physically the backup power supply module can be installed either in the separate backup power supply chassis LCH-C-X-XXXX or Luminato main chassis LCH-A-X-XXXX/LCH-D-X-XXXX, if the main chassis has two free slots in top of each other.
Separate backup power chassis LCH-C-X-XXXX can be installed either to a rack cabinet rail or wall mount.
Mount (slide) the backup power supply module LPS-CX-X/LPS-GX-X into the mounting frame LCHC-X-XXXX.
Note! Pay attention to the protection cover of the module when inserting (or removing) the power module. Under some circumstances it can get stuck to the mounting frame (modules manufactured before year 2011).
Tight the attachments screws (1) by hand and lock the module into place by attaching the locking screw (2) using screwdriver.
Mechanical installation
Luminato Power Supply Manual, rev0012 Installation 7
Note! Ensure that the Backup power supply unit is properly connected to the earth in order to meet safety requirements. Proper grounding will also improve the protection from the effects of interference and increase the overall reliability of the system. Ground the Mounting frame using the grounding screw (3).
Note! Alternatively the backup power supply module can also be mounted into a free (double high) module slot of the Luminato chassis.
1. ALARM – Connect to EXT 1 or EXT 2 on the Power
Supply unit LPS-BX-X. Alarm fan fail or too high temperature error is signalled to Luminato chassis.
2. 24 VDC – 24VDC output of external backup power supply. Totally 3 + 3 outputs.
3. Main power - Connect with a main cable to a grounded 100 - 240 VAC 50/60 Hz power outlet.
Connectors
Luminato Power Supply Manual, rev0012 Installation 8
Backup Power Supply LPS-FX-X Luminato uses external backup power for securing main power supply located in chassis. Backup Power is connected to the DC IN connector in the main power supply LPS-BX-X/LPS-EX-X or LPS-DX-X. Its internal switching circuit automatically takes power from external power supply, if main power supply fails.
Physically the backup power supply module can be installed either separate backup power supply chassis LCH-C-X-XXXX or Luminato main chassis LCH-A-X-XXXX/LCH-D-X-XXXX, if it has two free slots in top of each other.
Separate backup power chassis LCH-C-X-XXXX can be installed either to rack cabinet rail or wall mount.
Mount (slide) the backup power supply module LPS-FX-X into the mounting frame LCHC-X-XXXX.
Tight the attachments screws (1) by hand and lock the module into place by attaching the locking screw (2) using screwdriver.
Note! Ensure that the Backup power supply unit is properly connected to the earth in order to meet safety requirements. Proper grounding will also improve the protection from the effects of interference and increase the overall reliability of the system. Ground the Mounting frame using the grounding screw (3).
Mechanical installation
Luminato Power Supply Manual, rev0012 Installation 9
Note! Alternatively the backup power supply module can also be mounted into a free (double high) module slot of the Luminato chassis.
1. ALARM – Connect to EXT 1 or EXT 2 on the Power
Supply unit LPS-BX-X. Alarm fan fail or too high temperature error is signalled to Luminato chassis.
2. 24 VDC – 24VDC output of external backup power
supply. Totally 3 + 3 outputs.
3. DC input LED – shows that the DC input is valid (green), invalid (red) or not present (blank).
4. Main power - Connect with HDP001 cable to -48VDC
power supply.
Connectors
Luminato Power Supply Manual, rev0012 Installation 10
Backup power wiring
1. Connect the Alarm cable (LACCA) to the ALARM connector on the Backup Power Supply module LPS-CX-X/LPS-GX-X or LPS-FX-X and other end to the EXT 1 connector on the Power Supply module LPS-EX-X or LPS-DX-X.
2. Connect the Luminato backup PSU cable LACCA (min. 1.5 mm2 cable and max. length 2 m) to the 24 VDC connectors on the Backup Power Supply module LPS-CX-X/LPS-GX-X or LPS-FX-X and other end to the DC IN connector on the Power Supply module LPS-BX-X/LPS-EX-X or LPS-DX-X.
Note! Ensure that the Backup power supply is properly connected to the earth in order to meet safety requirements. Proper grounding will also improve the protection from the effects of interference and increase the overall reliability of the system. Ground the Mounting frame using the grounding screw.
1. Connect the Alarm cable to the ALARM connector on
the Backup Power Supply module LPS-CX-X/LPS-GX-
Backup Power Supply module LPS-GX-X or LPS-FX-X installed in a mounting frame
Backup Power Supply module LPS-GX-X or LPS-FX-X installed in a Luminato chassis
Luminato Power Supply Manual, rev0012 Installation 11
X or LPS-FX-X and other end to the EXT 1 connector on the Power Supply module LPS-BX-X/LPS-EX-X or LPS-DX-X.
2. Connect the Luminato backup PSU cable LACCA (min. 1.5 mm2 and max. length 2 m) to the 24 VDC connectors on the Backup Power Supply module LPS-GX-X or LPS-FX-X and to the DC IN connector on the Power Supply module LPS-BX-X/LPS-EX-X or LPS-DX-X.
Note! Ensure that the Luminato chassis are properly connected to the earth in order to meet safety requirements. Proper grounding will also improve the protection from the effects of interference and increase the overall reliability of the system. Ground the Mounting frame using the grounding screw.
Luminato Power Supply Manual, rev0012 Installation 12
Mounting frame LCH-C-X-XXXX
The Mounting frame LCH-C-X-XXXX can either be installed in a rack or on the wall. Use two M6 x 12 screws when mounting the frame in a rack.
Note! Ensure that the Mounting frame is properly connected to the earth in order to meet safety requirements. Proper grounding will also improve the protection from the effects of interference and increase the overall reliability of the system. Ground the Mounting frame using the grounding screw.
Mechanical installation
Luminato Power Supply Manual, rev0012 Environmental 13
Environmental
WEEE Notice
This product complies with the relevant clauses of the European Directive 2002/96/EC on Waste Electrical and Electronic Equipment (WEEE). The unit must be recycled or discarded according to applicable local and national regulations.
European Conformity
This equipment conforms to all applicable regulations and directives of European Union which concern it and has gone through relevant conformity assessment procedures.
Luminato Power Supply Manual, rev0012 Legal Declarations 14
Legal Declarations
Copyright Acknowledgements
Information in this document is subject to change without notice and does not represent a commitment on the part of Teleste Corporation. The software as described in this document is supplied only under a licence agreement. The software may be used or copied only in accordance with the terms of the agreement.
Copyright © 2011 Teleste Corporation. All Rights Reserved.
No part of this document may be reproduced, transmitted, stored in a retrieval system, or translated into any other language without the express permission of Teleste Corporation.