14
COPYRIGHT(C) 2020 HANGLAS ALL RIGHT RESERVRD Hankuk Glass Industries Co., Ltd. 5th Floor, Glass Tower Building, 534 Teheran-ro, Gangnam-gu, Seoul, Korea www.hanglas.co.kr HPe v1 2020 Power Catalogue Jul. 2020

Power Catalogue · Power Catalogue Industrial Bank of Korea KS145II·GS shop Better energy savings, Low-E glass COOL-LITE® K series are selective glass with advanced sun protection

  • Upload
    others

  • View
    2

  • Download
    0

Embed Size (px)

Citation preview

Page 1: Power Catalogue · Power Catalogue Industrial Bank of Korea KS145II·GS shop Better energy savings, Low-E glass COOL-LITE® K series are selective glass with advanced sun protection

CO

PY

RIG

HT

(C)

20

20

HA

NG

LAS

ALL

RIG

HT

RE

SE

RV

RD

Hankuk Glass Industries Co., Ltd.5th Floor, Glass Tower Building, 534 Teheran-ro,

Gangnam-gu, Seoul, Korea

www.hanglas.co.kr

HPe v1 2020

Power CatalogueJul. 2020

Page 2: Power Catalogue · Power Catalogue Industrial Bank of Korea KS145II·GS shop Better energy savings, Low-E glass COOL-LITE® K series are selective glass with advanced sun protection

The Technology for Tomorrow, HANGLAS

02

03

HA

NG

LAS

Po

wer C

atalog

ue

Contents04

06

1 0

1 4

1 5

1 6

20

22

23

24

COOL-LITE® XTREME

COOL-LITE® SK

COOL-LITE® K

COOL-LITE® Silver Series

COOL-LITE® Grey Series

PLANITHERM®

PLANITHERM® DURA Plus & DURA MAX

CONTRAFLAM®

PYROSWISS PLUS®

Performance Table

Page 3: Power Catalogue · Power Catalogue Industrial Bank of Korea KS145II·GS shop Better energy savings, Low-E glass COOL-LITE® K series are selective glass with advanced sun protection

04

05

HA

NG

LAS

Po

wer C

atalog

ue

COOL-LITE® XTREME

XT60-28II

XT70-33II

LH Korea Land & Housing Corporation

LH Korea Land & Housing Corporation

Orakai Daehakro Hotel

´

Extremely high selectivity solar control glassseries

XT60-28II XT70-33II

Incomparable performance,Triple silver Low-E coatingCOOL-LITE® XTREME series are the

latest innovation in high performance

solar control coatings.

So building occupants can benefit from

generous daylight with improved insulation,

while minimizing discomfort from

overheating in summer.

Page 4: Power Catalogue · Power Catalogue Industrial Bank of Korea KS145II·GS shop Better energy savings, Low-E glass COOL-LITE® K series are selective glass with advanced sun protection

COOL-LITE® SK

SKN363II·Seoul Forest Trimage

SKN154II

06

07

HA

NG

LAS

Po

wer C

atalog

ue

Make best decisions at work and in Life, Double silver Low-E coatingCOOL-LITE® SK series are the best solution to improve

the energy efficiency of buildings dramatically under

any environment conditions, hot or cold.

High performance solar control glassseries

SKG153II SKS143II SKN154II SKN176II

Incheon international airport Terminal 2

Pangyo 2nd Techno Valley Yongin Techno Valley Knowledge Industry Center

Lotte Mall Eunpyeong

SKS143II

Saemoonan Church

Page 5: Power Catalogue · Power Catalogue Industrial Bank of Korea KS145II·GS shop Better energy savings, Low-E glass COOL-LITE® K series are selective glass with advanced sun protection

SKN154II

08

09

HA

NG

LAS

Po

wer C

atalog

ue

Korea Electric Power Knowledge Data Network Company

Seoul Family Court

SaRang ChurchGyeonggi Center for Creative Economy & Innovation

JTBC Multicontents Center

Hyundai Marine & Fire Insurance Company

Sinchon Severance

SKN174II

Mediplex Sejong Hospital

JW Marriott Dongdaemun Square Seoul

Samsunglife Cheongdam-dong

Page 6: Power Catalogue · Power Catalogue Industrial Bank of Korea KS145II·GS shop Better energy savings, Low-E glass COOL-LITE® K series are selective glass with advanced sun protection

COOL-LITE® K

KS145II

KS145II

G-VALLEY

10

11

HA

NG

LAS

Po

wer C

atalog

ue

Industrial Bank of Korea

KS145II·GS shop

Better energy savings,Low-E glassCOOL-LITE® K series are selective glass with advanced

sun protection and good thermal insulation.

It can be the ideal product for many architectural

projects such as office buildings, mixed used

buildings and hotel.

Solar and thermal insulation glass for your comfortseries

KS145II KGrey147II

Green Cross R&D ceter

Gwanghwamun D Tower

Towe 8Daishin Securities Company

Gwanghwamun Centre point

DMC Digitalcube

Page 7: Power Catalogue · Power Catalogue Industrial Bank of Korea KS145II·GS shop Better energy savings, Low-E glass COOL-LITE® K series are selective glass with advanced sun protection

KS150II

Hanlasu coating plant·kunsan

12

13

HA

NG

LAS

Po

wer C

atalog

ue

Live Flex Tower

THE K Twin Tower City Center Tower AIA Tower

Korea Power ExchangePeitobilding Sinsadong

SK Plannet

KN152II

KGrey147II

Susong Square

Bundang U Tower

Daeryung Technotown 17 MVL Hotel Kintex

Gasan SK V

Page 8: Power Catalogue · Power Catalogue Industrial Bank of Korea KS145II·GS shop Better energy savings, Low-E glass COOL-LITE® K series are selective glass with advanced sun protection

14

15

HA

NG

LAS

Po

wer C

atalog

ue

seriesseriesLow-E glass with unique greycolor and improved heating and cooling efficiency!Sophisticated color with excellent thermal insulation

Technical specification

ProductVisible light

transmittance (%)

Visible light reflectance

(%)

U-Value(W/m2K)

Solar Heat Gain Coefficient

Coating

KS145II 40 33 1.06 0.26 Single

SKS143II 37 31 1.00 0.19 Double

※ 28T 6/16Ar/6 (#2) KS L 2525 standard

Towe 8

Live Flex Tower

Kolon One & Only Tower

Jakok Ace Tower

Pan Gyo second Techno Valley Business Growth Support Center

AIA Tower

COOL-LITE® SILVER SERIES COOL-LITE® GREY SERIES

SILV

ER

| GR

EY

COOL-LITE® SILVER series are applied together

with Low-E coating and reflective coating to

minimize the amount of solar energy from

the outside.

COOL-LITE® GREY series offer excellent

thermal insulation by Low-E glass and grey

aspect makes It the ideal product for

modern architecture.

BMW Deutsch Motors Company

KS145II SKS143II

Daishin Securities Company

ProductVisible light

transmittance (%)

Visible light reflectance

(%)

U-Value(W/m2K)

Solar Heat Gain Coefficient

Coating

Real grey 50 13 1.03 0.33 Single

KGrey147II 41 25 1.10 0.27 Single

KS345II 28 19 1.06 0.21 Single

SKG153II 49 16 1.00 0.26 Double

SKS343II 26 18 1.00 0.16 Double

※ 28T 6/16Ar/6 (#2) KS L 2525 standard

Technical specification

KGrey147II KS345II

Real Grey SKG153II SKS343II

Page 9: Power Catalogue · Power Catalogue Industrial Bank of Korea KS145II·GS shop Better energy savings, Low-E glass COOL-LITE® K series are selective glass with advanced sun protection

PLANITHERM®

16

17

HA

NG

LAS

Po

wer C

atalog

ue

Bright and cozy atmosphere, Low-E glassPLANITHREM® series combine highest level of

energy efficiency and transparency. It can provide a

comfortable indoor climate even in winter and

reduce noticeable the energy consumption.

LG company·Hapjeong

Meritzfire Company·Busan

Hakic Exllu Tower Sindorim D-Cube City

Pan Gyo Alphadom

LIG Company·Hapjeong

Daewoo Worldmark Centum

Get the best of energy efficiency and lightseries

Page 10: Power Catalogue · Power Catalogue Industrial Bank of Korea KS145II·GS shop Better energy savings, Low-E glass COOL-LITE® K series are selective glass with advanced sun protection

Boutiquemonaco

Twin Tree

Pan Gyo Chabio Complex

AmorepacificCompany·Busan

Amorepacific Company·Daejeon

National Institute of Ecology

Samsung Engineering Company

18

19

HA

NG

LAS

Po

wer C

atalog

ue

Amorepacific HQ

Page 11: Power Catalogue · Power Catalogue Industrial Bank of Korea KS145II·GS shop Better energy savings, Low-E glass COOL-LITE® K series are selective glass with advanced sun protection

PLANITHERM® DURA PLUS

20

21

HA

NG

LAS

Po

wer C

atalog

ue

Improved comfort Soft Low-E glassIt is a high performance low-E coated glass, to be processed

into an insulating glass unit, it reflects the far infrared

radiation thus limiting the heat transfer by radiation.

Benefits

Sealant can be used only when edge stripping is omitted

● Please keep in a dry, well-ventilated room.● Please keep in a room with low temperature and humidity to

prevent condensation on the glass.● Protect the coated surface from exposure with protective glass

after dissembling.

Storage precautions

Curtain walls must be applied after edge stripping.

Handling precautions

Edge stripping can be omitted

Can be used with various sealant Available

Retaining Neutral aestheticsProvide energy efficiency with very neutral aesthetics.

Superior durabilitySuperior durability minimizes scratch damage.

Excellent thermal insulation

It helps in naturally retaining the warmth

inside the building.

Long-term storageLong term

storage up to 12months.

Applications : Residential and Commercial buildings

Company Product Type Company Product Type

Dowcorning DC939, DC982 2-Component SiliconeDongyang Silicone

IGS707 Pair-seal 1-Component Silicone

Shinetsu FC312, FC322 2-Component Silicone Ecoseal300, Ecoseal 3000 2-Component Silicone

Sika IG-16K, IG-25A 2-Component Silicone Shinwoo Chemical PLUS998 1-Component Silicone

GE IGS3110, IGS3723 2-Component Silicone TOPLA TOPSEAL(IGS606) 1-Component Silicone

FENZI Thiover 2-Component Thiokol WACKER LC999 1-Component Silicone

Dawoo SealantPair-seal 1-Component Silicone MOA silicone MR-808 Pair-seal 1-Component Silicone

DGS3110 2-Component Silicone Tremco-illbruck JS562 2-Component Silicone

HS HM-PS-1000R 2-Component Thiokol

Maximizing the entry of natural daylight

Page 12: Power Catalogue · Power Catalogue Industrial Bank of Korea KS145II·GS shop Better energy savings, Low-E glass COOL-LITE® K series are selective glass with advanced sun protection

CONTEAFLAM® PYROSWISS PLUS®

Opera House Copenhagen·Denmark Entrance

22

23

HA

NG

LAS

Po

wer C

atalog

ue

Effectively reduces the transmission of radiated and conducted heat

keeping it transparent and perfectly intact

Limiting heat transmission or spread of fire,

or keep fires within the fire compartment of

origin, consequently, allows to fire fighting

and evacuation for 60~120 minutes.

Intended to prevent smoke, flames and hot

toxic gases up to 1 hour at 945℃. By keeping

it transparent and perfectly intact, Pyroswiss

assists rescue services so they know about

urgent hazard.

EI CLASS Fire resistant glass E Class Fire resistant glass

Division

Cate-gorize

Integrity (Class E)

Integrity + Insulation (Class EI)

Limit the spread of fire, smoke and gases

Limit the spread of fire, smoke, gases and heat

transmission

Con-tents

Note

Integrity Integrity + Insulation

Integrity only Radiation heat and temperature rise on the glass surface will deliver fire to the other side after the fire.

Integrity + insulation It prevents spread of fire and ensure the safety of people by blocking the heats after the fire.

Comparison of Integrity and Integrity + Insulation

Charles de Gaulle Airport Paris·France

Acropolis Museum·Greece

Page 13: Power Catalogue · Power Catalogue Industrial Bank of Korea KS145II·GS shop Better energy savings, Low-E glass COOL-LITE® K series are selective glass with advanced sun protection

Performance Table

24

25

HA

NG

LAS

Po

wer C

atalog

ue

Triple Silver Low-E coating

CompositionVisible Light(%) Solar Energy(%) Shading

Coefficient

Solar Heat Gain

Coefficient

U-Value (W/m2K) Relative Heat Gain

(W/m2)Transmittance Reflectance Transmittance Reflectance NFRC KS

6Xtreme60-28II 67 11 25 47 0.34 0.29 3.19 2.88 230

6Xtreme60-28II + 12A + 6CL 60 14 22 48 0.30 0.26 1.64 1.55 198

6Xtreme60-28II + 12Ar + 6CL 60 14 22 48 0.29 0.25 1.33 1.18 192

6Xtreme60-28II + 16A + 6CL 60 14 22 48 0.29 0.25 1.68 1.30 194

6Xtreme60-28II + 16Ar + 6CL 60 14 22 48 0.29 0.25 1.39 1.02 189

6Xtreme70-33II 77 6 30 40 0.39 0.34 3.16 2.85 265

6Xtreme70-33II + 12A + 6CL 69 11 26 41 0.34 0.30 1.62 1.54 228

6Xtreme70-33II + 12Ar + 6CL 69 11 26 41 0.34 0.29 1.31 1.16 221

6Xtreme70-33II + 16A + 6CL 69 11 26 41 0.34 0.29 1.67 1.28 223

6Xtreme70-33II + 16Ar + 6CL 69 11 26 41 0.33 0.29 1.37 1.00 218

Double Silver Low-E coating

● The optical and thermal properties are calculated on the basis of NFRC.● U-value by KS is calculated on the basis of KS L 2003, KS L 2525● Permissible tolerance

- Transmittance and reflectance : ± 3% (According to EN1096-4) - SC , SHGC : ± 0.03 - U-value : ± 0.03 W/m2K (Emissivity ± 1%)

● Coated side of double glazing unit is #2● Performance figures are characteristic after heat strength● The performance data are calculated by spectrum and may differ from actual values. ● The performance data may be changed without prior notice in order to improve performance.● COOL-LITE® Series can not be used as a single glazing (double glazing required).

In addition, edge stripping is required for the production of double glazing.

CompositionVisible Light(%) Solar Energy(%) Shading

Coefficient

Solar Heat Gain

Coefficient

U-Value (W/m2K) Relative Heat Gain

(W/m2)Transmittance Reflectance Transmittance Reflectance NFRC KS

6SKN154 57 15 25 36 0.36 0.31 3.15 2.85 242

6SKN154 + 12A + 6CL 52 18 22 37 0.31 0.27 1.61 1.54 206

6SKN154 + 12Ar + 6CL 52 18 22 37 0.30 0.26 1.30 1.16 198

6SKN154 + 16A + 6CL 52 18 22 37 0.30 0.26 1.66 1.28 201

6SKN154 + 16Ar + 6CL 52 18 22 37 0.30 0.26 1.36 1.00 194

6SKN154II 56 15 24 29 0.36 0.31 3.14 2.85 243

6SKN154II + 12A + 6CL 51 18 21 30 0.30 0.26 1.61 1.54 202

6SKN154II + 12Ar + 6CL 51 18 21 30 0.29 0.25 1.29 1.16 193

6SKN154II + 16A + 6CL 51 18 21 30 0.30 0.26 1.66 1.28 197

6SKN154II + 16Ar + 6CL 51 18 21 30 0.29 0.25 1.35 1.00 189

SKN176II 75 8 35 31 0.46 0.40 3.15 2.85 309

SKN176II + 12A + 6CL 67 13 31 33 0.41 0.35 1.61 1.54 268

SKN176II + 12Ar+ 6CL 67 13 31 33 0.40 0.35 1.30 1.16 263

SKN176II + 16A + 6CL 67 13 31 33 0.40 0.35 1.66 1.28 261

SKN176II + 16Ar + 6CL 67 13 31 33 0.40 0.35 1.36 1.00 258

6SKN374II 54 5 27 16 0.42 0.36 3.22 2.93 280

6SKN374II + 12A + 6CL 48 8 23 17 0.34 0.30 1.65 1.59 229

6SKN374II + 12Ar + 6CL 48 8 23 17 0.33 0.29 1.34 1.22 219

6SKN374II + 16Ar + 6CL 48 8 23 17 0.34 0.29 1.70 1.34 223

6SKN374II + 16Ar + 6CL 48 8 23 17 0.33 0.29 1.40 1.07 215

6SKS143II 41 30 18 42 0.28 0.24 3.15 2.85 193

6SKS143II + 12A + 6CL 37 31 16 43 0.23 0.20 1.61 1.54 159

6SKS143II + 12Ar + 6CL 37 31 16 43 0.22 0.20 1.30 1.16 150

6SKS143II + 16A + 6CL 37 31 16 43 0.23 0.20 1.66 1.29 153

6SKS143II + 16Ar + 6CL 37 31 16 43 0.22 0.19 1.36 1.00 147

SKS343II 29 17 13 23 0.27 0.23 3.15 2.85 185

6SKS343II + 12A + 6CL 26 18 11 23 0.20 0.18 1.61 1.54 139

6SKS343II + 12Ar + 6CL 26 18 11 23 0.19 0.16 1.30 1.16 127

6SKS343II + 16A + 6CL 26 18 11 23 0.20 0.17 1.66 1.29 133

6SKS343II + 16Ar + 6CL 26 18 11 23 0.19 0.16 1.36 1.00 124

6SKG153II 55 14 25 36 0.36 0.31 3.15 2.85 242

6SKG153II + 12A + 6CL 49 16 22 37 0.30 0.26 1.61 1.54 204

6SKG153II + 12Ar + 6CL 49 16 22 37 0.30 0.26 1.30 1.16 196

6SKG153II + 16A + 6CL 49 16 22 37 0.30 0.26 1.66 1.29 198

6SKG153II + 16Ar + 6CL 49 16 22 37 0.29 0.26 1.36 1.00 192

Solar Control Low-E glass

CompositionVisible Light(%) Solar Energy(%) Shading

Coefficient

Solar Heat Gain

Coefficient

U-Value (W/m2K) Relative Heat Gain

(W/m2)Transmittance Reflectance Transmittance Reflectance NFRC KS

COOL-LITE Real grey 55 11 32 18 0.45 0.40 3.17 2.88 303

6Real grey + 12A + 6CL 50 13 27 20 0.39 0.34 1.63 1.56 256

6Real grey + 12Ar + 6CL 50 13 27 20 0.38 0.33 1.32 1.18 247

6Real grey + 16A + 6CL 50 13 27 20 0.38 0.33 1.67 1.31 251

6Real grey + 16Ar + 6CL 50 13 27 20 0.37 0.33 1.38 1.03 243

6KGrey147II 46 23 26 29 0.38 0.33 3.25 2.97 260

6KGrey147II + 12A + 6CL 41 25 22 30 0.32 0.28 1.67 1.62 217

6KGrey147II + 12Ar + 6CL 41 25 22 30 0.32 0.28 1.37 1.25 209

6KGrey147II + 16A + 6CL 41 25 22 30 0.32 0.28 1.72 1.37 212

6KGrey147II + 16Ar + 6CL 41 25 22 30 0.31 0.27 1.43 1.10 206

6KS145II 44 31 25 36 0.36 0.31 3.21 2.92 243

6KS145II + 12A + 6CL 40 33 21 37 0.31 0.27 1.65 1.59 206

6KS145II + 12Ar + 6CL 40 33 21 37 0.30 0.26 1.34 1.21 199

6KS145II + 16A + 6CL 40 33 21 37 0.30 0.26 1.69 1.34 201

6KS145II + 16Ar + 6CL 40 33 21 37 0.30 0.26 1.40 1.06 196

6KS345II 31 18 18 21 0.32 0.28 3.21 2.92 219

6KS345II + 12A + 6CL 28 19 15 21 0.25 0.22 1.65 1.59 172

6KS345II + 12Ar + 6CL 28 19 15 21 0.24 0.21 1.34 1.21 161

6KS345II + 16A + 6CL 28 19 15 21 0.25 0.22 1.69 1.34 166

6KS345II + 16Ar + 6CL 28 19 15 21 0.24 0.21 1.40 1.06 158

Double glazing #2 Low-e coating

Double glazing #2 Low-e coating

● The optical and thermal properties are calculated on the basis of NFRC.● U-value by KS is calculated on the basis of KS L 2003, KS L 2525● Permissible tolerance

- Transmittance and reflectance : ± 3% (According to EN1096-4) - SC , SHGC : ± 0.03 - U-value : ± 0.03 W/m2K (Emissivity ± 1%)

● Coated side of double glazing unit is #2● Performance figures are characteristic after heat strength● The performance data are calculated by spectrum and may differ from actual values. ● The performance data may be changed without prior notice in order to improve performance.● COOL-LITE® Series can not be used as a single glazing (double glazing required).

In addition, edge stripping is required for the production of double glazing.

Page 14: Power Catalogue · Power Catalogue Industrial Bank of Korea KS145II·GS shop Better energy savings, Low-E glass COOL-LITE® K series are selective glass with advanced sun protection

26

27

HA

NG

LAS

Po

wer C

atalog

ue

Performance Table

Double glazing # 3 Low-e coating

Double glazing # 3 Low-e coating

Low-E glass

● The optical and thermal properties are calculated on the basis of NFRC.● U-value by KS is calculated on the basis of KS L 2003, KS L 2525● Permissible tolerance

- Transmittance and reflectance : ± 3% (According to EN1096-4) - SC , SHGC : ± 0.03 - U-value : ± 0.03 W/m2K (Emissivity ± 1%)

● Coated side of double glazing unit is #3● Performance figures are characteristic after heat strength● The performance data are calculated by spectrum and may differ from actual values. ● The performance data may be changed without prior notice in order to improve performance.● PLANITHERM® can not be used as a single glazing (double glazing required).

In addition, edge stripping is required for the production of double glazing.

● The optical and thermal properties are calculated on the basis of NFRC.● U-value by KS is calculated on the basis of KS L 2003, KS L 2525● Permissible tolerance

- Transmittance and reflectance : ± 3% (According to EN1096-4) - SC , SHGC : ± 0.03 - U-value : ± 0.03 W/m2K (Emissivity ± 1%)

● Coated side of double glazing unit is #3● Performance figures are characteristic after heat strength● The performance data are calculated by spectrum and may differ from actual values. ● The performance data may be changed without prior notice in order to improve performance.● PLANITHERM® can not be used as a single glazing (double glazing required).

In addition, edge stripping is required for the production of double glazing.

CompositionVisible Light(%) Solar Energy(%) Shading

Coefficient

Solar Heat Gain

Coefficient

U-Value (W/m2K) Relative Heat Gain

(W/m2)Transmittance Reflectance Transmittance Reflectance NFRC KS

5PLT DURA+ 77 7 55 17 0.68 0.59 3.47 3.21 449

5CL + 12A + 5PLT DURA+ 69 11 47 21 0.72 0.63 1.79 1.76 469

5CL + 12Ar + 5PLT DURA+ 69 11 47 21 0.73 0.63 1.50 1.42 471

6PLT DURA+ 77 7 54 16 0.68 0.59 3.46 3.20 449

6CL + 12A + 6PLT DURA+ 69 11 45 20 0.70 0.61 1.79 1.75 457

6CL + 12Ar + 6PLT DURA+ 69 11 45 20 0.71 0.62 1.50 1.41 458

5PLT DURA+(HS) 82 6 57 17 0.70 0.61 3.43 3.16 460

5CL + 12A + 5PLT DURA+(HS) 74 11 48 22 0.72 0.62 1.77 1.73 466

5CL + 12Ar + 5PLT DURA+(HS) 74 11 48 22 0.72 0.63 1.48 1.39 467

6PLT DURA+(HS) 82 6 56 16 0.70 0.61 3.42 3.15 461

6CL + 12A + 6PLT DURA+(HS) 73 11 47 21 0.70 0.61 1.76 1.73 455

6CL + 12Ar + 6PLT DURA+(HS) 73 11 47 21 0.70 0.61 1.47 1.38 455

5 PLT DURA Max 75 11 47 27 0.59 0.51 3.27 2.98 387

5CL + 12A + 5PLT DURA Max 68 13 40 30 0.62 0.54 1.68 1.62 403

5CL + 12Ar + 5PLT DURA Max 68 13 40 30 0.62 0.54 1.37 1.25 403

5CL + 16Ar + 5PLT DURA Max 68 13 40 30 0.63 0.55 1.43 1.10 403

6 PLT DURA Max 75 11 46 25 0.58 0.51 3.25 2.97 384

6CL + 12A + 6PLT DURA Max 67 13 39 28 0.61 0.53 1.67 1.61 397

6CL + 12Ar + 6PLT DURA Max 67 13 39 28 0.61 0.53 1.37 1.25 397

6CL + 16Ar + 6PLT DURA Max 67 13 39 28 0.62 0.54 1.43 1.10 397

5 PLT DURA Max (HS) 77 11 48 28 0.59 0.52 3.24 2.95 393

5CL + 12A + 5PLT DURA Max (HS) 69 15 41 30 0.61 0.53 1.67 1.60 399

5CL + 12Ar + 5PLT DURA Max (HS) 69 15 41 30 0.62 0.54 1.36 1.23 399

5CL + 16Ar + 5PLT DURA Max (HS) 69 15 41 30 0.62 0.54 1.42 1.08 399

6 PLT DURA Max (HS) 77 11 47 26 0.59 0.51 3.23 2.95 389

6CL + 12A + 6PLT DURA Max (HS) 69 14 40 29 0.60 0.53 1.66 1.60 393

6CL + 12Ar + 6PLT DURA Max (HS) 69 14 40 29 0.61 0.53 1.35 1.23 393

6CL + 16Ar + 6PLT DURA Max (HS) 69 14 40 29 0.61 0.53 1.41 1.08 392

CompositionVisible Light(%) Solar Energy(%) Shading

Coefficient

Solar Heat Gain

Coefficient

U-Value (W/m2K) Relative Heat Gain

(W/m2)Transmittance Reflectance Transmittance Reflectance NFRC KS

6PLA UNII 87 6 57 24 0.69 0.60 3.26 2.98 454

6CL + 12A + 6PLA UNII 78 12 48 26 0.65 0.57 1.68 1.62 425

6CL + 12Ar + 6PLA UNII 78 12 48 26 0.65 0.57 1.37 1.26 423

6CL + 16A + 6PLA UNII 78 12 48 26 0.65 0.57 1.72 1.38 423

6CL + 16Ar + 6PLA UNII 78 12 48 26 0.66 0.57 1.43 1.11 422

6PLA ONEII 77 18 48 36 0.57 0.50 3.17 2.88 379

6CL + 12A + 6PLA ONEII 70 22 41 35 0.54 0.47 1.63 1.56 353

6CL + 12Ar + 6PLA ONEII 70 22 41 35 0.54 0.47 1.32 1.18 350

6CL + 16A + 6PLA ONEII 70 22 41 35 0.54 0.47 1.67 1.31 351

6CL + 16Ar + 6PLA ONEII 70 22 41 35 0.54 0.47 1.38 1.03 348

Low-E glass