11
10 Weighing Electronics RAAD Box Smart Sensor Network With the RAAD Box , conventional strain gauge load cell systems can be transformed into advanced sensor networks. Instead of analyzing the combined signal from the load cells in the system, the RAAD Box embeds intelligence into each individual load cell, enabling you to analyze your system at the lowest level. Failures can be detected immediately, guard- ing you against costly downtime or product waste. Power and Performance for Weighing Applications IND110 Weight Transmitter The IND110 provides an economi- cal way to connect an analog strain gauge scale or weigh mod- ules via 4-20mA to process control equipment. IND131 Process Transmitter This newest generation of process transmitters combines ultra-fast A/D conversion and digital filter- ing with a compact footprint and a wide choice of process interfaces. A crisp OLED display makes con- figuration very convenient. Also available in a junction box design for harsh and heavy washdown applications. IND331 Process Terminal All you get from an IND131, but additionally with a panel-mountable display. The design allows to panel mount the entire terminal as well as remote installation of the display, separate from the electronic. Also available in a desk/wall-mountable harsh housing. Model IND110 IND131 / IND 131xx IND331 / IND331xx Resolution (max.) Approved 4,000 divisions, (non-approved) 100,000 divisions, OIML Class III 6,000e, NTEP Class III/IIIL 10,000d MID approvals available 100,000 divisions, OIML Class III 6,000e NTEP Class III/IIIL 10,000d MID approvals available Housing Plastic Plastic (DIN rail) Stainless steel enclosure (J-Box) Stainless steel front (panel) Stainless steel enclosure (harsh) Protection IP20, Type 1 IP20, Type 1 (DIN rail) IP69k (J-Box) IP65, Type 4x and 12 (panel front); IP66, Harsh (not approved for Haz applications) Interfaces 4 - 20mA 4-20 mA, AB RIO, DeviceNet, Profibus DP, Ethernet IP, Modbus TCP, ControlNet and serial with support for Modbus RTU 4-20 mA, AB RIO, DeviceNet, Profibus DP, Ethernet IP, Modbus TCP, ControlNet and serial with support for Modbus RTU Power 20 to 28VDC, 300 mA max. 85-264 VAC or 24 VDC; IND131xx available in 24VDC version only 85-264 VAC or 24 VDC; IND331xx avail- able in 24VDC version only Applications Signal conversion, tank weighing Tank and simple process weighing, level indication and loss-in-weight Tank and simple process weighing, level indication and loss-in-weight Number of attachable scales Single platform, up to 4 load cells or weigh modules Single platform, up to 8 350 Ω load cells (AC version), up to 4 350 Ω load cells (DC version) or weigh modules Single platform, up to 8 350 Ω load cells (AC version), up to 4 350 Ω load cells (DC version) Page 191 193, 197 195, 197

Power and Performance for Weighing Applications€¦ · Scale type Analog load cells Number of cells Up to 8 350 Ω load cells (AC version), up to 4 350 load cells (DC version), 2

  • Upload
    others

  • View
    9

  • Download
    0

Embed Size (px)

Citation preview

Page 1: Power and Performance for Weighing Applications€¦ · Scale type Analog load cells Number of cells Up to 8 350 Ω load cells (AC version), up to 4 350 load cells (DC version), 2

10

Weig

hing

Elec

troni

csRAAD Box™ Smart Sensor Network With the RAAD Box™, conventional strain gauge load cell systems can be transformed into advanced sensor networks. Instead of analyzing the combined signal from the load cells in the system, the RAAD Box embeds intelligence into each individual load cell, enabling you to analyze your system at the lowest level. Failures can be detected immediately, guard-ing you against costly downtime or product waste.

Power and Performance for Weighing Applications

IND110 Weight TransmitterThe IND110 provides an economi-cal way to connect an analog strain gauge scale or weigh mod-ules via 4-20mA to process control equipment.

IND131 Process TransmitterThis newest generation of process transmitters combines ultra-fast A/D conversion and digital filter-ing with a compact footprint and a wide choice of process interfaces. A crisp OLED display makes con-figuration very convenient. Also available in a junction box design for harsh and heavy washdown applications.

IND331 Process TerminalAll you get from an IND131, but additionally with a panel-mountable display. The design allows to panel mount the entire terminal as well as remote installation of the display, separate from the electronic. Also available in a desk/wall-mountable harsh housing.

Model IND110 IND131 / IND 131xx IND331 / IND331xxResolution (max.)Approved

4,000 divisions, (non-approved) 100,000 divisions, OIML Class III 6,000e,NTEP Class III/IIIL 10,000dMID approvals available

100,000 divisions, OIML Class III 6,000eNTEP Class III/IIIL 10,000d MID approvals available

Housing Plastic Plastic (DIN rail)Stainless steel enclosure (J-Box)

Stainless steel front (panel)Stainless steel enclosure (harsh)

Protection IP20, Type 1 IP20, Type 1 (DIN rail)IP69k (J-Box)

IP65, Type 4x and 12 (panel front); IP66, Harsh (not approved for Haz applications)

Interfaces 4 - 20mA 4-20 mA, AB RIO, DeviceNet, Profi bus DP, Ethernet IP, Modbus TCP, ControlNet and serial with support for Modbus RTU

4-20 mA, AB RIO, DeviceNet, Profibus DP, Ethernet IP, Modbus TCP, ControlNet and serial with support for Modbus RTU

Power 20 to 28VDC, 300 mA max. 85-264 VAC or 24 VDC; IND131xx available in 24VDC version only

85-264 VAC or 24 VDC; IND331xx avail-able in 24VDC version only

Applications Signal conversion, tank weighing Tank and simple process weighing, level indication and loss-in-weight

Tank and simple process weighing, level indication and loss-in-weight

Number of attachable scales

Single platform, up to 4 load cells or weigh modules

Single platform, up to 8 350 Ω load cells (AC version), up to 4 350 Ω load cells (DC version) or weigh modules

Single platform, up to 8 350 Ω load cells (AC version), up to 4 350 Ω load cells (DC version)

Page 191 193, 197 195, 197

Bob
Highlight
Page 2: Power and Performance for Weighing Applications€¦ · Scale type Analog load cells Number of cells Up to 8 350 Ω load cells (AC version), up to 4 350 load cells (DC version), 2

191

Weig

hing

Elec

troni

cs

IND110Weight Transmitter

Customer benefits • Compact footprint uses minimal amount of valuable

enclosure space• DIN rail mounting for easy, fast installation• Setpoint outputs included• Remote sense inputs provide load cell cable

resistance compensation and allow for use with intrinsically safe barrier

• Digital filtering increases accuracy across entire weight range and in applications with vibration

• Simple and fast calibration, with zero calibration independent of span calibration value• Global approvals provide product acceptance in

local markets• Harsh and 7/9 enclosure optionally available

Direct Interface to PLCsand Other Control Equipment

ConnectEasy integration into process-based network architectures provides valuable plant-floor information that can be used to optimize production and help reduce down-time.

Complywith global regulations and standards. Harsh and 7/9 enclosure optionally available. 7/9 enclosure is certified safe for use in most Division 1 or 2 hazardous classified areas.

Page 3: Power and Performance for Weighing Applications€¦ · Scale type Analog load cells Number of cells Up to 8 350 Ω load cells (AC version), up to 4 350 load cells (DC version), 2

192

Parameter Specifi cationModel No. IND110Display none LED Indicators Power ON with external power supplied HI ON when load cell signal > high setpoint LO ON when load cell signal < low setpointTemperature Range Operating -10 ~ +45 °C (14 ~ +113°F)ATEX Approval (1) Number (7/9 enclos. only) DEMCO ATEX 0303070U (certifi cate for fl ameproof enclosure) Rating EExd IIB H2 IP66.Haz Approval (1) Number (7/9 enclos. only) UL number QUZW.E152336 Rating Class I, Div 1, Groups C-D Class II, Div 1, Groups E-G Class III Div 1 Remarks HazLoc approval only in conjunction with ISB15 or ISB15x barrier.Approvals UL, cUL, CE marked (UL fi le E139501 for module, E152336 for 7/9 ecnlosure) Load Cell Input Excitation Voltage 10 VDC, 120 mA max. (4x 350 Ohm cells) Load Cell Range 1.5 to 3 mV/V with full bridge Span Adjustment Range 25% to 110% of cell capacity @ 2 mV/V Zero Adjustment Range 0 to 100% of load cell output @ 2 mV/VOutputs Discrete 1 low & 1 high level output, open collector type, 5 to 25 VDC, 60 mA max sink current Analogue Signal: 4 to 20 mA (1 mA to 24 mA limits) Load resistance 0 to 500 Ohm maxLinearity +/- 0.012% maxTemperature Stabillity <20 ppm/°C (span), 50 ppm/°C (zero)Update Rate 20/second Calibration DIP switch mode selection enables front panel calibration of load cell zero/span and setpoint low/high limits Protection IP65 (optional Type 4x enclosure) Power Supply 20 to 28 VDC, 300 mA max., 8 watts Class 2 power supplyWeight 0.18 kg (0.39 lb)Mounting 35mm DIN rail (module only) or wall mount (optional enclosure)

1) See certifi cate for complete information

IND110 Weight Transmitter Specifi cations

IND110 Weight Transmitter Ordering Information

Description Item No.IND110 Load Cell Signal Converter DIN Rail 71208076Type 4X Enclosure for IND110 64053670IND110 Load Cell Signal Converter incl. 7/9 enclosure 64053672

www.mt.com/IND110

Weig

hing

Elec

troni

cs

Page 4: Power and Performance for Weighing Applications€¦ · Scale type Analog load cells Number of cells Up to 8 350 Ω load cells (AC version), up to 4 350 load cells (DC version), 2

193

Weig

hing

Elec

troni

cs

IND131 / IND331 Weighing Terminals

The IND131 and IND331 analog scale terminals deliver precision measurement data in a single, cost-effective package. Each terminal features:

• Ultra-fast A/D conversion rate• Patented TraxDSP® digital filtering• Organic LED display readable in all light conditions• Enclosures designed to match application environment• Modular design, multiple mounting possibilities• Support for a wide variety of options, including DIO,

additional serial port, and PLC interfaces• Choice of AC or 24 VDC power supply• Portable calibration/configuration settings and firmware

upgrades via an SD memory card• Scale calibration through PLC interface• CalFREE® allows scales to be tested without test weights

Max Connectivity, Mini Footprint Easy Integration for Weighing

The IND131/IND331 deliv-ers excellent accuracy, reliability and efficiency for process weighing applications.

Designed with the per-formance and reliability expected of Weights and Measures and product safety compliant terminals, these superior weighing terminals include features and functionality never before offered in such a compact and versatile form factor.

The inherent qualities of process weighing ter-mi nals from METTLER TOLEDO make it easier for OEMs and System Integrators to build best-in-class weighing systems cost-effectively.

Easy integration into pro-cess-based network archi-tectures provides valuable plant-floor information to process owners to opti-mize production and help reduce down-time.

Page 5: Power and Performance for Weighing Applications€¦ · Scale type Analog load cells Number of cells Up to 8 350 Ω load cells (AC version), up to 4 350 load cells (DC version), 2

194

IND131 / IND331Specifications

IND131/DIN IND331/Panel IND131/JBox IND331/Harsh

Enclosure typesUnit of

Measure DIN rail-mount, plastic, with operator interface

Panel mount, stainless steel

+ plastic chassis

Stainless steelenclosure including

internal boardto sum load cells

Stainless steel desk-or wall-mountable

enclosure, with operator interface

Dimensions* L × H × D mmin.

68 × 138 × 1112.7 × 5.4 × 4.4

Front panel:168 × 68 × 126.6 × 2.7 × 0.5

251 × 261 × 1239.9 × 10.3 × 4.8

220 × 131 × 1778.7 × 5.2 × 7.0

Shipping weight kg / lb 1 / 2.2 1.5 / 3.3 5.5 / 12.1 3 / 6.5

Environmental protection IP20, Type 1 IP65, Type 4x and 12 IP69k IP66

Ambient environmentOperation °C / °F -10 to 40 / 14 to 104, 10 % to 90 % relative humidity, non-condensing

Storage °C / °F -20 to 60 / -4 to 140, 10 % to 90 % relative humidity, non-condensing

Power requirementsAC version VAC / Hz / mA 85-264 / 49-61 / 27-73

DC version VDC / mA 18-36; nominal 24 / 84-170; nominal 120 (IND131), nominal 130 (IND331)

DisplayType Green OLED including weight display, weight units, gross/net indication and graphic symbols for motion and

center of zero. 10 updates/sec.

Character height mm / in. 5.6 / 0.22 12 / 0.47 5.6 / 0.22 (internal) 12 / 0.47

Weight display Maximum displayed resolution of 100 ,000 divisions

Scale type Analog load cells

Number of cells Up to 8 350 Ω load cells (AC version), up to 4 350 Ω load cells (DC version), 2 or 3 mV/V

Number of scales 1

Analog/Digital update rates Hz Internal analog: 366 / Target comparison: 50 / PLC Interface: 20

Digital Filtering TraxDSP®

Memory Stores two-speed target control values and limit values for three comparators

Applications Basic process weighing for gain-in-weight (filling), loss-in-weight (dosing) and level indication

Load cell excitation voltage VDC 5

μV Build Minimum/Approved microvolts 0.1 / 0.6

Keypad 4 keys (Clear, Zero, Tare, Print); 1.22 mm thick polyester overlay (PET) with polycarbonate display lens

Communications

Serial inter-faces

Standard: One serial port (COM1), RS-232, 300 to 115,200 baudOptional: Serial port (COM2), RS-232/485, 300 to 115,200 baud

Protocol Serial inputs: ASCII commands for CTPZ (Clear, Tare, Print, Zero), SICS (most commands, levels 0 and 1)Serial outputs: Continuous, Extended continuous, or Demand (limited formats)

Approvals

Weights andMeasures

USA: NTEP Class III/IIIL - 10,000d; CoC 09-051Canada: Class III/IIIHD - n max. 10000/20000;

AM-5744Europe: OIML, Class III, 6000e; R76/2006-NL1-09.26

MID OIML R51 (Automatic Catchweighing) T10262; OIML R61 (Automatic Gravimetric Weighing) T10261

Product Safety UL, cUL, CE

* Dimensional drawings are included on following pages

Options and AccessoriesMultiple PLC Options

COM2 / DIO, includes:

– COM2 RS-232/485 serial, 4 discrete outputs, solid state or relay

– Modbus RTU capability, 2 discrete inputs (selectable active or passive)

72229290 Panther Terminal adapter plate for IND331 Panel unit

71209353 Wall mounting bracket (for IND331 Harsh unit)

22015188 Swivel mounting bracket (for IND331 Harsh unit)

72229289 2GB SD Memory Card for configuration and calibration data backup and restore

All IND131 and IND331 terminals can be equipped with any of a wide array of PLC options, including:

• 4-20mA Analog output

• Allen-Bradley RIO

• DeviceNet™

• EtherNet/IP™

• Modbus TCP

• PROFIBUS® DP

• ControlNet™ (24 VDC units only)

• Modbus RTU

www.mt.com/IND131-331

Page 6: Power and Performance for Weighing Applications€¦ · Scale type Analog load cells Number of cells Up to 8 350 Ω load cells (AC version), up to 4 350 load cells (DC version), 2

195

Weig

hing

Elec

troni

cs

IND131xx and IND331xxProcess Weighing in Hazardous Areas

IND131xx / IND331xxWeighing Terminals

The IND131xx and IND331xx analog scale terminals deliver precision measurement data in a single, cost-effective package, safe for use in Zone 2/22 and Division 2/Zone 2 hazardous areas. Terminal features include:

• Organic LED display readable in all light conditions• Ultra-fast A/D conversion rate and TraxDSP® digital

filtering• Enclosures designed to match application

environment − modular design enables multiple mounting possibilities

• 24 VDC operation• Support for a wide variety of options, including DIO,

additional serial port, and PLC interfaces• Portable calibration/configuration settings and

firmware update via an SD memory card• Scale calibration through PLC interface. CalFREE®

allows scales to be calibrated without test weights

Zone 2/22, Division 2

With the performance and reliability expected of Weights and Measures and product safety compliant terminals, the inherent properties of these process weighing terminals from METTLER TOLEDO make it easier for OEMs and System Integrators to build best-in-class weighing systems cost-effectively.

The IND131/IND331 deliv-ers excellent diagnostics, reliability and efficiency for process weighing applications. These supe-rior weighing terminals include features and functionality never before offered in such a compact and versatile form factor.

Easy integration into pro-cess-based network archi-tectures provides valuable plant-floor information that can be used to opti-mize production and help reduce down-time.

IECEx

Page 7: Power and Performance for Weighing Applications€¦ · Scale type Analog load cells Number of cells Up to 8 350 Ω load cells (AC version), up to 4 350 load cells (DC version), 2

196

IND131xx / IND331xxSpecifications

IND131xxDIN mounted

IND331xxPanel mounted

IND131xxJBox enclosure

Enclosure types Unit ofMeasure

DIN rail-mount, plastic, with operator interface

Panel mount, stainless steel with operator interface + plastic chassis

Stainless steelenclosure including

internal boardto sum load cells

Dimensions L × H × D mmin.

68 × 138 × 1112.7 × 5.4 × 4.4

Front panel:168 × 68 × 126.6 × 2.7 × 0.5

251 × 261 × 1239.9 × 10.3 × 4.8

Shipping weight kg / lb 1 / 2.2 1.5 / 3.3 5.5 / 12.1

Environmental protection IP20, Type 1 IP65, Type 4x and 12 IP69k

Ambient environmentOperation °C / °F -10 to 40 / 14 to 104, 10 % to 90 % relative humidity, non-condensing

Storage °C / °F -20 to 60 / -4 to 140, 10 % to 90 % relative humidity, non-condensing

Power requirements VDC / mA 18-36; nominal 24 / 84-170; nominal 120 (IND131xx), nominal 130 (IND331xx)

DisplayType Green OLED including weight display, weight units, gross/net indication and graphic symbols for motion and center

of zero. 10 updates/sec.

Character height mm / in. 5.6 / 0.22 12 / 0.47 5.6 / 0.22 (internal)

Weight display Maximum displayed resolution of 100 ,000 divisions

Scale type Analog load cells

Number of cells Up to 4 350 Ω load cells, 2 or 3 mV/V

Number of scales 1

Analog/Digital update rates Hz Internal analog: 366 / Target comparison: 50 / PLC Interface: 20

Digital Filtering TraxDSP®

Memory Stores two-speed target control values and limit values for three comparators

Application Basic process weighing for gain-in-weight (filling), loss-in-weight (dosing) and level indication

Load cell excitation voltage VDC 5

μV Build Minimum/Approved microvolts 0.1 / 0.6

Keypad 4 keys (Clear, Zero, Tare, Print); 1.22 mm thick polyester overlay (PET) with polycarbonate display lens

Communications

Serialinterfaces

Standard: One serial port (COM1), RS-232, 300 to 115,200 baudOptional: Serial port (COM2), RS-232/485, 300 to 115,200 baud

ProtocolSerial inputs: ASCII commands for CTPZ (Clear, Tare, Print, Zero),

SICS (most commands, levels 0 and 1)Serial outputs: Continuous, Extended continuous, or Demand (limited formats)

Approvals

Weights andMeasures

USA: NTEP Class III/IIIL - 10,000d; CoC 09-051Canada: Class III/IIIHD - n max. 10,000/20,000; AM-5744

Europe: OIML, Class III, 6000e; R76/2006-NL1-09.26

Hazardous locations

MID OIML R51 (Automatic Catchweighing) T10262OIML R61 (Automatic Gravimetric Weighing) T10261

Product safety, ordinarylocations

UL, cUL, CE

USA - FM Canada - FM ATEX IECEx NEPSI

NI / I, II, III / 2 / ABCDEFG / T5 Ta = 40°C

I / 2 / IIC / T5 Ta = 40°C

NI / I / 2 / ABCD / T5 Ta = 40°C

DIP / II, III / 2 / EFG / T5 Ta = 40°C

II 3 G Ex nA nL [nL] IIC T5II 3 D Ex tD A22 IP 65 T

100°C

Ex nA nL [nL] IIC T5Ex tD A22 IP65 T100°C

Pending

Install per Control Drawing 72238303R Install per Installation Drawing 72246295R

* Dimensional drawings are included on following pages

Page 8: Power and Performance for Weighing Applications€¦ · Scale type Analog load cells Number of cells Up to 8 350 Ω load cells (AC version), up to 4 350 load cells (DC version), 2

197

Weig

hing

Elec

troni

cs

IND131 and IND331 Packaged SolutionsEnhanced Terminals in Robust Enclosures

• IND131 and IND331 in enclosure with optional I/O• Each version can be configured with any of the terminals’

multiple interface and connectivity • Optional DC power supply available

Enclosure SpecificationsEnclosures are also available in painted mild steel (shown at left), stainless steel and fiberglass. The stainless steel enclo-sure housing the IND131 DIN and IND331 panel packaged solutions is rated IP66 (IP65, when used with IND331 panel mount terminal). Each type includes integrated mounting back-ets, and if required can be configured with a power supply.

Multiple Terminal Configurations AvailableWhen a single terminal is not enough, multi-terminal designs are available, with power supply, optional I/O, and additional features as required for the application.

Faster basic process controlThe IND131/IND331 combination serial and relay Discrete I/O option allows the terminal or terminals to be configured for efficient process control. User selection of latched or concidence targets in combination with user-configured limit values for up to three comparators create a time-saving and cost-effective process controller.

Customized InterfacesCustomize the packaged IND131 and IND331 for specific uses with convenient operators for I/O, such as annunciators and pushbuttons, making operator interactions even easier, more consistent and safer.

Page 9: Power and Performance for Weighing Applications€¦ · Scale type Analog load cells Number of cells Up to 8 350 Ω load cells (AC version), up to 4 350 load cells (DC version), 2

198

IND131xx and IND331xx Packaged Solutions

• Packaged IND131xx and IND331xx in Enclosures Approved for Division 2, Zone 2 and Zone 22

• Each version can be configured with any of the terminals' multiple interface and connectivity options

• Packages include an agency-approved 24 VDC power supply

Enclosure SpecificationsThe stainless steel enclosure housing the IND131xx DIN and IND331xx panel packaged solutions is FM-approved for use in safe areas, and in Division 2, Zone 2 hazardous areas. The enclosure is ATEX/IECEx certified for Zone 22 (dust) hazardous areas. Cable entry points can be either conduit hubs for use in the U.S., or ATEX-approved glands for European applications.• FM-certified enclosure, gas and dust • ATEX and IECEx certified for Zone 2/22 environments• Rated IP66, IP65 when used with panel-mount terminal• T5 temperature class rating

Multi-Terminal ConfigurationsWhen a single terminal is not enough, multi-terminal designs are available, with agency-approved power supply, optional ISB (Intrinsically Safe Barrier) and additional features as required for the application.

Load Cells in Hazardous AreasIn applications with load cells in-stalled in Division 1/Zone 1 or Zone 1/21 areas, an intrinsically safe ana-log load cell barrier (ISB) is required. IND131xx and IND331xx terminals packaged with a METTLER TOLEDO ISB05 provide an integrated solution for such applications.

Packaged Model Configurations

IND131xx and IND331xx packages are highly customizable. Figure 1 shows a system compris-ing an IND131xx with optional ISB05 barrier. Figure 2 shows an IND331xx panel-mount terminal (its front panel interface not shown). Packaged model configurations include an FM/CSA/ATEX approved power supply (24VDC at 1.3 A, 100-240 VAC, 50/60 Hz) and are available with any of the PLC inter-faces (EtherNet/IP, PROFIBUS DP, Modbus TCP, Allen-Bradley RIO, ControlNet, Device-Net), and Solid State DIO.

Figure 1 Figure 2

IND131xx-based• ISB05 (optional), ATEX glands

(for European installations)• FM, ATEX and IECEx- certified

enclosure

IND331xx-based, standard(front panel display not shown)• Conduit hubs (for installation in

US/Canada)• FM, ATEX and IECEx-certified

enclosure

IECEx

Weig

hing

Elec

troni

cs

Page 10: Power and Performance for Weighing Applications€¦ · Scale type Analog load cells Number of cells Up to 8 350 Ω load cells (AC version), up to 4 350 load cells (DC version), 2

199

IND331, Harsh enclosure

IND131/IND131xx, DIN-mount enclosure

138 [5.43]

130 [5.12]

ø2.5 [R0.1]

68 [

2.68

]

100

[3.9

6]

110.

5 [4

.35]

220 [8.66]

130.

5 [5

.14]

176.9 [6.96]

145.8 [5.74]

120 [4.72]

95 [

3.74

]

M4 [0.16]

IND131/IND131xx/IND331/IND331xxDimensional Drawings in mm and [inches]

IND331/331xx, Panel-mount

Template for IND331 panel mounting cut-outs

148.2 [5.3]

74.1 [2.92]35 [1.38]

9.9 [0.39]

40 [1.57]

14 [0.55]

6 - ø4.5 [0.17]

3 [0.12] ø30 [1.18]46 [1

.81]

31 [1

.22]

156 [6.14]130 [5.12]

110.

5 [4

.35]

11 [0.43]

40 [1

.57]

00.5

[3.

96]

115.

2 [4

.96]

168 [6.61]

R4 [0.16]

68 [

2.68

]

60 [

2.38

]

68 [

2.68

]

Panel

Page 11: Power and Performance for Weighing Applications€¦ · Scale type Analog load cells Number of cells Up to 8 350 Ω load cells (AC version), up to 4 350 load cells (DC version), 2

200

249.

5 [9

.82]

IND131/IND131xx, J-box enclosure

184 [7.24]

200 [7.87]237 [9.33]

164.

1 [6

.46]

144.

8 [5

.70]

125.

5 [4

.94]

223.5 [8.80]250.8 [9.87]

237 [9.33]200 [7.87]

168.

7 [6

.64]

165.

7 [6

.52]

151.

5 [5

.97]

Ø 12.7 [0.5]

R3.6 [0.14]

IND131/IND131xx /IND331/IND331xxModel Identification

www.mt.com/IND131-331