Upload
others
View
2
Download
0
Embed Size (px)
Citation preview
Polypipe Underfloor Heating
Trade Price List 2020NEW
PRODUCTS
P&HDLTPL9 MAY 2020
EFFECTIVE: 1st MARCH 2020
www.polypipeufh.com2
Welcome to the new Polypipe Underfloor Heating Trade Price List. This handy pocket guide combines all of our related products into one single catalogue of product and price information.
Alongside all of our best known product ranges, you will also find several exciting new additions, continuing our reputation for product innovation and great value. Together they make Polypipe the most comprehensive range of plumbing and heating systems available from a single UK manufacturer.
Underfloor HeatingTrade Price List 2020
Be sure to check out these great new products:
Page 20 Overlay™ Plus A versatile addition to the established Overlay™ range
Page 36 Smart Controls A complete range in three different options, simple,
standard and smart.
Page 40 Smart Plus Controls Additions to the Smart Plus Controls range for
controlling mixed systems
Page 45 Heat Generation Single Zone Electric Boiler for Underfloor Heating
For the latest product and support information, literature downloads, product selectors and news, visit us online at www.polypipeufh.com
Underfloor Heating SystemsUnderfloor Heating Pipe Page 5
Solid Floor SystemsRed Floor Panel System Page 7
Clip Rail System Page 8
Staple System Page 9
Floating Floor SystemFloating Floor System Page 11
Suspended Floor SystemsDouble Heat Spreader Plate Page 14
Fit From Below Double Heat Spreader Plate Page 14
Overlay™ Lite 15 Page 15
Modular Heating Panels Page 16
Existing Floors & Low Profile SystemsOverlay™ Plus For all floor coverings Page 20
Overlay™ Heavy floor coverings Page 21
Overlay™ Lite 15 Larger areas or whole house solutions Page 22
Manifolds & Water Temperature ControlsStainless Steel Underfloor Heating Page 26 Manifolds & Ancilliaries
Polymer Manifolds & Ancillaries Page 28
Brass Underfloor Heating Manifolds & Ancilliaries Page 30
Water Temperature Controls Page 32
Room Temperature ControlsRoom Temperature Controls Page 36
Room PacksRoom Packs Page 42
Heat GenerationSingle Zone Electric Boiler for Underfloor Heating Page 45
Renewable Pipe SystemsRenewable Pipe Systems Page 46
You can find out more about Polypipe Underfloor Heating Systems at www.polypipeufh.com
Contents
www.polypipeufh.com 3
www.polypipeufh.com4
UnderfloorHeating Systems
Polypipe manufactures the most comprehensive range of underfloor heating systems available for the UK market.
Our range combines versions of traditional underfloor systems and a number of innovative product solutions, designed to extend the suitability of underfloor heating to almost any installation scenario, from whole house to single room projects and for new build and renovations.
For more information, consult our Installation Guide or use the online product selectors at www.polypipeufh.com
Underfloor Heating Pipe Polybutylene
PackQty.
Code No.
Price Each £
12mm x 25m Coil UFH Pipe 1 UFH2512B 34.57
12mm x 50m Coil UFH Pipe 1 UFH5012B 69.12
12mm x 80m Coil UFH Pipe 1 UFH8012B 110.58
15mm x 50m Coil UFH Pipe 1 UFH5015B 72.78
15mm x 80m Coil UFH Pipe 1 UFH8015B 116.45
15mm x 100m Coil UFH Pipe 1 UFH10015B 145.56
15mm x 120m Coil UFH Pipe 1 UFH12015B 174.68
15mm x 150m Coil UFH Pipe 1 UFH15015B 218.35
15mm x 500m Coil UFH Pipe 1 UFH50015B 727.80
18mm x 120m Coil UFH Pipe 1 UFH12018B 208.96
18mm x 200m Coil UFH Pipe 1 UFH20018B 348.27
18mm x 300m Coil UFH Pipe 1 UFH30018B 522.41
Pipe Decoiler PackQty.
Code No.
Price Each £
Adjustable pipe decoiler for pipes coils up to 500m 1 UFHDECOIL 305.15
Conduit Pipe Conduit Polypropylene Pipe Coil
PackQty.
Code No.
Price Each £
15mm x 25 metre (Black) 1 UFHCP1525 24.54
Polypipe MCP Underfloor Heating Pipe (For Underfloor Heating Use Only) - EN21003 Class S
Metal Composite Pipe PackQty.
Code No.
Price Each £
16mm x 80m Coil MCP UFH Pipe 1 MCP8016B 130.58
16mm x 100m Coil MCP UFH Pipe 1 MCP10016B 163.22
16mm x 120m Coil MCP UFH Pipe 1 MCP12016B 195.86
16mm x 150m Coil MCP UFH Pipe 1 MCP15016B 244.83
www.polypipeufh.com 5
Polypipe Ultra Flexible Underfloor Heating Pipe (For Underfloor Heating Use Only) - EN15876
Red Floor Panel SystemFor optimum performance, Polypipe has the perfect solution for installing underfloor heating into solid or screeded floors. Utilising our unique lightweight plastic floor panels, which are quick and easy to cut to size, it is possible to fit Polypipe Underfloor Heating into any shaped room. The lightweight plastic floor panels also nest for easy storage and carrying.
Clip Rail and Staple SystemsWe also provide a range of rail and staple systems that fit directly onto the insulation, offering a more traditional alternative to installing underfloor heating in solid or screeded floors.
Optimum performance system
www.polypipeufh.com6
Underfloor heating for solid screeded floors
Solid Floor Systems
Panel System
Floor PanelAllow for overlap and waste when ordering
PackQty.
Code No.
Price Each £
1.2m x 1m 1 PB08576 9.56
Standard UFCH Pipe Clip PackQty.
Code No.
Price Each £
Standard UFCH Pipe Clip 250 PB02911 0.11
Edge Expansion PackQty.
Code No.
Price Each £
25m Coil 1 PB05855 29.25
Long Radius Bend Former PackQty.
Code No.
Price Each £
For use as pipe guide at bottom of manifold - accepts 15mm conduit pipe
1 PB6325 14.68
Plastic Pipe Stiffeners PackQty.
Code No.
Price Each £
15mm UFH pipe stiffener 30 UFHPS15 0.31
www.polypipeufh.com 7
Solid Floor Systems
1
2
3
4
5
6
*See technical guide for floor coverings.
Panel System
1. Insulation
2. Pipe
3. Red Floor Panel
4. Edge expansion
5. Screed
6. Finished floor*
1
2
3
4
5
Clip Rail System
Clip Rails
200mm pipe centres (15mm pipe) & 200mm & 300mm pipe centres (18mm pipe).Use approx 1m/m2 floor area and secure with standard Pipe Clip PB02911.
PackQty.
Code No.
Price Each £
15-18mm pipe 16 x 1m pack (16m) 16 PB08515 3.03
Standard UFCH Pipe Clip PackQty.
Code No.
Price Each £
Standard UFCH Pipe Clip 250 PB02911 0.11
Edge Expansion PackQty.
Code No.
Price Each £
25m Coil 1 PB05855 29.25
Long Radius Bend Former PackQty.
Code No.
Price Each £
For use as pipe guide at bottom of manifold - accepts 15mm conduit pipe
1 PB6325 14.68
Plastic Pipe Stiffeners PackQty.
Code No.
Price Each £
15mm UFH pipe stiffener 30 UFHPS15 0.31
1. Insulation
2. Pipe
3. Edge expansion
4. Clip rail
5. Screed
6. Finished floor*
Clip Rail System
www.polypipeufh.com8
Solid Floor Systems
6
*See technical guide for floor coverings.
1
2
3 4
5
Staple System
UFCH Staple System PackQty.
Code No.
Price Each £
UFCH Staple Clip (40mm) 300 PB02940 0.14
UFCH Staple Clip (60mm) 300 PB02930 0.14
UFCH Staple Gun 1 PB02931 250.75
Edge Expansion PackQty.
Code No.
Price Each £
25m Coil 1 PB05855 29.25
Long Radius Bend Former PackQty.
Code No.
Price Each £
For use as pipe guide at bottom of manifold - accepts 15mm conduit pipe
1 PB6325 14.68
Plastic Pipe Stiffeners PackQty.
Code No.
Price Each £
15mm UFH pipe stiffener 30 UFHPS15 0.31
Staple System
www.polypipeufh.com 9
Solid Floor Systems
1. Insulation
2. Pipe
3. Edge expansion
4. UFCH Staple Clip
5. Screed
6. Finished floor*
*See technical guide for floor coverings.
6
www.polypipeufh.com10
The Polypipe Floating Floor System features high density polystyrene floor panels that enhance insulation, as well as providing the base for the heating pipes.
The system is designed for use with “dry build” floors laid directly over solid or timber sub bases in both new build and existing properties.
Floating Floor Systems are compatible with our 15mm pipe systems.
Underfloor heating for floating floors
Floating Floor Systems
1
2 3
4 5
6
1. Fits over concrete or floorboards
2. Floating Floor panel
3. Pipe
4. End return
5. 10mm plywood lining
6. Suitable for laminate and engineered wood floors direct*
Floor Panel PackQty.
Code No.
Price Each £
1200mm (L) x 800mm (W) x 50mm (D) 10 PB08050 41.03
Connection/Return panel 10 PB08060 10.80
www.polypipeufh.com 11
Floating Floor System
Coverage approx. 9.6m2 per 10 pack
Self Adhesive Aluminium Tape
PackQty.
Code No.
Price Each £
48mm wide x 46 metres long 1 UFHALTP 12.29
Plastic Pipe Stiffeners PackQty.
Code No.
Price Each £
15mm UFH pipe stiffener 30 UFHPS15 0.31
*See technical guide for floor coverings.
Optimum performance system
www.polypipeufh.com12
For suspended timber and composite joists, typically found in new build and renovation projects - Polypipe offers a range of unique pre-insulated and pre-configured systems, as well as more traditional suspended floor underfloor heating options. Giving you a solution for every type of suspended floor installation.
Double Heat Spreader Plates (DHSP)Offering a simple installation system for traditional joists and spacings, Double Heat Spreader Plates can also be used in ‘sprung’ flooring systems such as sports halls.
This system uses aluminium Double Heat Spreader Plates to transmit the heat evenly across the finished floor surface.
Underfloor heating for suspended floors
Suspended Floor Systems
Fit From Above with Overlay™ Lite 15 - Suspended floor applicationFor enhanced performance, especially over larger floor areas, use with our new Overlay™ Lite 15 panels for an integrated insulated solution.
Fit From Below (FFB) Double Heat Spreader PlateSuitable for use with traditional or composite joists, this system offers the ability to fit from below, even if the floor above has already been installed.
Perfect for cellars or where upper floor coverings are already in place.
Modular Heating PanelsFor the ultimate quick and easy installation solution, use our pre-configured, insulated panels that include all the system components already integrated. The panels are supplied in sized panels which are simply fitted and connected together on site.
All systemsFor use with our 15mm pipe systems. All suspended floor systems are fitted within the joists so do not add any build height to the floor.
www.polypipeufh.com 13
Suspended Floor System
1
2
3
4
5 6
1. Ceiling
2. Supporting joists
3. Insulation
4. Double Heat Spreader Plate
5. Pipe
6. Timber or chipboard floor deck*
Double Heat Spreader Plate
2
1 3
4 5
Double Heat Spreader Plate
Double Heat Spreader PlatePipe grooves at 125mm each side of centre line
PackQty.
Code No.
Price Each £
For 15mm Pipe, 450mm x 1m span double indent 5 PB209 11.98
For 15mm Pipe, 390mm x 1m span double indent at 200mm centres
40 PB240 9.10
FFB Double Heat Spreader Plate
FFB Double Heat Spreader Plate
PackQty.
Code No.
Price Each £
For 15mm Pipe, 310mm x 1m span double indent 5 PB206 16.72
1. Supporting joists
2. Insulation
3. FFB Double Heat Spreader Plate
4. Pipe
5. Timber or chipboard floor deck*
Fit From Below (FFB) Double Heat Spreader Plate
www.polypipeufh.com14
Suspended Floor Systems
*See technical guide for floor coverings.
3 4
5
1
2
Overlay™ Lite 15
Overlay™ Lite 15 Floor Panel PackQty.
Code No.
Price Each £
1200mm (L) x 800mm (W) x 22mm (D) Coverage approx. 9.6m2 per 10 pack
10 PB08030 34.21
Plastic Pipe Stiffeners PackQty.
Code No.
Price Each £
15mm UFH pipe stiffener 30 UFHPS15 0.31
1. Ceiling
2. Supporting joists
3. Overlay™ Lite 15
4. Pipe
5. Timber or chipboard floor deck*
Fit From Above With Overlay™ Lite 15
www.polypipeufh.com 15
Suspended Floor Systems
*See technical guide for floor coverings.
3
4
1
2
MHP (Modular Heating Panel)
MHP (Modular Heating Panel)
PackQty.
Code No.
Price Each £
330mm x 1.3m 5 MHP33013 23.14
380mm x 1.3m 5 MHP38013 23.14
330mm x 2.0m 5 MHP33020 30.87
380mm x 2.0m 5 MHP38020 30.87
490mm x 1.3m 5 MHP49013 30.87
490mm x 2.0m 5 MHP49020 41.15
MHP (Modular Heating Panel)
www.polypipeufh.com16
Suspended Floor Systems
1. Ceiling
2. Supporting joists
3. MHP panel including pipe, insulation and foil diffuser
4. Timber or chipboard floor deck
www.polypipeufh.com 17
Optimum performance system
For existing solid or timber deck floors - Polypipe’s unique Overlay™ underfloor heating range of low profile systems are installed over the existing floor. This makes them ideal for renovation and new build, whole house and single room projects.
www.polypipeufh.com18
Underfloor heating that goes over the floor
Existing Floors & Low Profile Systems
Overlay™ PlusPolypipe’s patented Overlay™ Plus underfloor heating board is a low-profile system that has been designed to be installed over existing floors. Making it the ideal product for renovation and new build projects.
Overlay™Overlay™ accommodates all types of project and floor coverings, and the only choice is that of which panel will be most appropriate for the installation. Both Overlay™ and Overlay™ Lite can be used for the majority of projects, however the choice of Overlay™ is determined by floor covering selection. Overlay™ and Overlay™ Lite can be used as appropriate in the same project.
The more structural nature of Overlay™, however, makes it ideal for direct tiling or application of floor finishes which need to be fixed or screwed to the panel.
Overlay™ Lite 15Slightly deeper profile, which can be used on top of a supporting floor or as a low profile alternative to floating floor. The system delivers the same responsive heat but is configured to be more suitable for larger, “whole house” projects.
www.polypipeufh.com 19
Existing Floors & Low Profile Systems
1
2 3
4
5
Choose Overlay™ Plus floor panels for use with all floor coverings including tiles, and ceramics.
Overlay™ Plus
Overlay™ Plus Floor Panel PackQty.
Code No.
Price Each £
1200mm (L) x 600mm (W) x 18mm (D) 50 UFHOP50 25.86
1200mm (L) x 600mm (W) x 18mm (D) 10 UFHOP10 27.45
Overlay™ Plus Acoustic Floor Panel
PackQty.
Code No.
Price Each £
1200mm (L) x 600mm (W) x 18mm (D) 50 UFHOPA50 39.47
1200mm (L) x 600mm (W) x 18mm (D) 5 UFHOPA5 41.32
End Returns PackQty.
Code No.
Price Each £
End Returns 10 PB08573 2.66
MS Adhesive PackQty.
Code No.
Price Each £
Solvent free MS Adhesive (290ml) 1 UFHMS1 16.03
Solvent free MS Adhesive (600ml) 6 UFHMS6 12.80
Adaptor Set (Overlay™ & Overlay™ Lite)
PackQty.
Code No.
Price Each £
15mm x 12mm including Pipe Stiffeners 2 PB181512 3.86
Polypipe Self Levelling Compound
PackQty.
Code No.
Price Each £
Specifically designed UFH self-levelling compound (13kg bag) Coverage: approx 4m2 at 3mm thick
1 UFHM13 49.00
1. Fits over concrete or floorboards
2. 120mm x 600mm x 18mm OverlayTM Plus panel
3. 12mm polybutylene barrier pipe
4. End return
5. Suitable for tiles, hard wood floorsand LVT’s*
www.polypipeufh.com20
Overlay™ Plus Floor System
*See technical guide for floor coverings.
1
2 3
4
5
Choose Overlay™ original floor panels for use with heavier floor coverings such as tiles and ceramics.
Overlay™
Overlay™ Floor Panel PackQty.
Code No.
Price Each £
800mm (L) x 600mm (W) x 18mm (D) Coverage approx. 14·4m2 per 30 pack
30 PB08571 17.16
800mm (L) x 600mm (W) x 18mm (D) Coverage approx. 4.8m2 per 10 pack
10 PB08570 18.03
End Returns(Overlay™ & Overlay™ Lite)
PackQty.
Code No.
Price Each £
End Returns 10 PB08573 2.66
Polyurethane Expanding Foam Glue
PackQty.
Code No.
Price Each £
Polyurethane Expanding Foam Glue (Overlay™) 1 PB776 16.03
Adaptor Set (Overlay™ & Overlay™ Lite)
PackQty.
Code No.
Price Each £
15mm x 12mm including Pipe Stiffeners 2 PB181512 3.86
Temperature Limiting Valve PackQty.
Code No.
Price Each £
Temperature Limiting Valve 5m2 Overlay™ only 1 PB970010 74.20
1. Fits over concrete or floorboards
2. 800mm x 600mm x 18mm OverlayTM panel
3. 12mm polybutylene barrier pipe
4. End return
5. Suitable for tiles and hard wood floors*
www.polypipeufh.com21
Overlay™ Floor System
*See technical guide for floor coverings.
1
2
3
4
5
6
Choose Overlay™ Lite 15 floor panels, with 15mm pipe, for larger floor areas.
Overlay™ Lite 15
Overlay™ Lite 15 Floor Panel PackQty.
Code No.
Price Each £
1200mm (L) x 800mm (W) x 22mm (D) Coverage approx. 9.6m2 per 10 pack
10 PB08030 34.21
Connection/Return panel 10 PB08040 8.98
Self Adhesive Aluminium Tape
PackQty.
Code No.
Price Each £
48mm wide x 46 metres long 1 UFHALTP 12.29
Plastic Pipe Stiffeners PackQty.
Code No.
Price Each £
15mm UFH pipe stiffener 30 UFHPS15 0.31
12mm Cover Board PackQty.
Code No.
Price Each £
Tongue and groove cover board1200mm (L) x 800mm (W) x 12mm (D)
50 UFHCOVER50 50.10
Acoustic Edge Roll 150mm x 8mm x 10 metres 1 UFHACEDGE 25.08
www.polypipeufh.com22
Overlay™ Lite 15 Floor System
1. Fits over concrete or floorboards
2. Overlay™ Lite 15 panel
3. Pipe
4. End return
5. 10mm plywood lining
6. Suitable for laminate and engineered wood floors*
*See technical guide for floor coverings.
• 3kw Heating Element
• 2 Port Push Fit Manifold
• Internal Pump
• Expansion
• Pressure Relief
• Pressure Guage
• Filling Connections
• Air Vent
The new Single Zone Electric Boiler means that underfloor heating can now be installed as a standalone system - removing the need to plumb into the existing heating system.
This sleek, white comapct unit can supply hot water to service underfloor heating in areas up 38m2*.
For more information, visit: www.polypipeufh.com/singlezoneboiler
NEW Single Zone Electric Boiler
UFHEHU
www.polypipeufh.com 23
*Based on a requirement of 80w/m2. For help specifying your system contact our Design Engineers via [email protected]
www.polypipeufh.com24
www.polypipeufh.com 25
Manifolds are used in all underfloor heating systems above 30m2, irrespective of floor type. Manifolds are supplied complete and fixed with a wall mounting bracket. The manifold comes complete with a drain and air vent assembly, which can be positioned on either end of the manifold, and isolation valves are supplied separately for the supply end of the manifold.
We offer a range of 15mm push-fit manifolds for use with 12mm and 15mm pipe systems and compression manifolds for use with our 16mm and 18mm pipe systems.
Each Polypipe manifold includes a flow meter on each flow port to provide a visual indicator of the flow through rate of each circuit.
Polypipe also offers a range of water temperature control units. These are used to reduce the water temperature for underfloor heating systems, when connected to the same boiler used for radiators or stored hot water, which operate at higher temperatures than underfloor systems.
Polypipe offers a broad range of manifold and water temperature controls for both traditional and underfloor heating applications, now including the new Stainless Steel Manifold with Secure Fix Bracket.
Manifolds & Water Temperature Controls
15mm Stainless Steel Manifold Push-fit (now with Auto Balancing Technology)For use with 15mm and 12mm Overlay™ Systems
PackQty.
Code No.
Price Each £
2 Port - Push-fit Manifold 1 PB12752 159.85
3 Port - Push-fit Manifold 1 PB12753 192.44
4 Port - Push-fit Manifold 1 PB12754 236.81
5 Port - Push-fit Manifold 1 PB12755 254.59
6 Port - Push-fit Manifold 1 PB12756 303.44
7 Port - Push-fit Manifold 1 PB12757 333.04
8 Port - Push-fit Manifold 1 PB12758 370.04
9 Port - Push-fit Manifold 1 PB12759 402.60
10 Port - Push-fit Manifold 1 PB12760 436.66
11 Port - Push-fit Manifold 1 PB12761 473.65
12 Port - Push-fit Manifold 1 PB12762 510.66
Stainless Steel Isolation Valves
PackQty.
Code No.
Price Each £
1 inch - Isolation Valves - use to connect manifolds to both UFCH Control Pack & Modulating Pump Unit (Pair)
1 PB12764 36.37 per pair
Stainless Steel Isolation Valves
PackQty.
Code No.
Price Each £
1 inch - Isolation Valves - use to connect UFCH Control Pack to system pipework
1 PB12765 36.37 per pair
www.polypipeufh.com26
Stainless Steel Underfloor Heating Manifolds and Ancillaries
15mm Stainless Steel Manifold Extension Kit
PackQty.
Code No.
Price Each £
Underfloor Central Heating Manifold Extension Kit 1 UFHABEXT 91.95
per pair
Stainless Steel Manifold Spares and Accessories
Manifold Flow Meter PackQty.
Code No.
Price Each £
Manifold Flow Meter 1 PB129FM 15.29
Manifold Balancing Valve PackQty.
Code No.
Price Each £
Manifold Balancing Valve 1 PB129BV 11.66
Manifold Blue Cap PackQty.
Code No.
Price Each £
Manifold Blue Cap 1 PB129BC 1.67
Manifold End Set PackQty.
Code No.
Price Each £
Manifold End Set (Pair) 1 PB129ES 38.91 per pair
Comissioning Hose PackQty.
Code No.
Price Each £
For filling and draining 1 PB12766 20.90
UFCH Manifold Bends (90o) PackQty.
Code No.
Price Each £
Allows pump unit and manifold to be corner mounted, can be used with UFCH control pack
1 PB12768 91.95
Female Coupler PackQty.
Code No.
Price Each £
Female Coupler 22mm X 1” 2 UFH170 12.84
Temperature Gauge PackQty.
Code No.
Price Each £
Temperature Gauge 1 PB129TG 13.77
www.polypipeufh.com 27
Stainless Steel Underfloor Heating Manifolds and Ancillaries
15mm Plastic Manifold Push-fitFor use with 15mm and 12mm Overlay™ Systems
PackQty.
Code No.
Price Each £
2 Port - Push-fit Manifold 1 UFHMANP2 99.45
3 Port - Push-fit Manifold 1 UFHMANP3 119.72
4 Port - Push-fit Manifold 1 UFHMANP4 147.34
5 Port - Push-fit Manifold 1 UFHMANP5 158.39
6 Port - Push-fit Manifold 1 UFHMANP6 188.79
7 Port - Push-fit Manifold 1 UFHMANP7 207.20
8 Port - Push-fit Manifold 1 UFHMANP8 230.22
9 Port - Push-fit Manifold 1 UFHMANP9 250.48
10 Port - Push-fit Manifold 1 UFHMANP10 271.67
11 Port - Push-fit Manifold 1 UFHMANP11 294.69
12 Port - Push-fit Manifold 1 UFHMANP12 317.71
Isolation Valves PackQty.
Code No.
Price Each £
1 inch - Isolation Valves - use to connect manifolds to both UFCH Control Pack & Modulating Pump Unit (Pair)
1 UFHIVP1 31.50 per pair
www.polypipeufh.com28
Plastic Underfloor Heating Manifolds and Ancillaries
Plastic Manifold Spares and Accessories
Manifold Flow Meter PackQty.
Code No.
Price Each £
Manifold Flow Meter 1 UFHMANPFM 14.29
Manifold Balancing Valve PackQty.
Code No.
Price Each £
Manifold Balancing Valve 1 UFHMANPBV 10.10
Manifold Blue Cap PackQty.
Code No.
Price Each £
Manifold Blue Cap 1 UFHMANPWC 1.56
Manifold End Set PackQty.
Code No.
Price Each £
Manifold End Set (Pair) 1 UFHMANPES 36.36 per pair
Plastic Underfloor Heating Manifolds and Ancillaries
www.polypipeufh.com 29
16mm and 18mm Compression ManifoldFor use with 16mm MCP and 18mm systems
Use with Manifold Unions
PackQty.
Code No.
Price Each £
2 Port - Compression Manifold 1 PB08351 159.85
3 Port - Compression Manifold 1 PB08392 192.44
4 Port - Compression Manifold 1 PB08459 236.81
5 Port - Compression Manifold 1 PB08462 254.59
6 Port - Compression Manifold 1 PB08479 303.44
7 Port - Compression Manifold 1 PB08558 333.04
8 Port - Compression Manifold 1 PB08563 370.04
9 Port - Compression Manifold 1 PB08564 402.60
10 Port - Compression Manifold 1 PB08572 436.66
11 Port - Compression Manifold 1 PB08588 473.65
12 Port - Compression Manifold 1 PB08589 510.66
16mm and 18mm Manifold UnionsTo be used on each Manifold Port
PackQty.
Code No.
Price Each £
16mm 1 PB07729 4.06
18mm 1 PB07730 4.06
UFCH Manifold Bends (90°) PackQty.
Code No.
Price Each £
Allows pump unit and manifold to be corner mounted, can be used with UFCH Control Pack or Modulating Pump Unit (Pair)
1 PB12735 41.01per pair
Isolation Valves PackQty.
Code No.
Price Each £
1 inch - Isolation Valves - use to connect manifolds to both UFCH Control Pack & Modulating Pump Unit (Pair)
1 PB01732 36.37per pair
www.polypipeufh.com30
Brass Underfloor Heating Manifolds and Ancillaries
ONLY WHILE
STOCKSLAST
Brass Manifold Spares and Accessories
Manifold Flow Meter PackQty.
Code No.
Price Each £
Manifold Flow Meter 1 PB127FM 15.29
Manifold Balancing Valve PackQty.
Code No.
Price Each £
Manifold Balancing Valve 1 PB127BV 11.66
Manifold Blue Cap PackQty.
Code No.
Price Each £
Manifold Blue Cap 1 PB127BC 1.67
Manifold End Set PackQty.
Code No.
Price Each £
Manifold End Set (Pair) 1 PB127ES 38.91 per pair
Temperature Gauge PackQty.
Code No.
Price Each £
Temperature Gauge 1 PB127TG 14.73
www.polypipeufh.com 31
Brass Underfloor Heating Manifolds and Ancillaries
ONLY WHILE
STOCKSLAST
Multiple Room Systems
Stainless Steel Manifold Control Pack
PackQty.
Code No.
Price Each £
UFCH Control Pack - Includes EUP Pump, UFCH Mixer Valve, bend and adaptors. For use with Stainless Steel Manifolds only (see page 26-27).
1 PB970055 404.34
High Limit Thermostat PackQty.
Code No.
Price Each £
Provides additional protection from high temperature water. For use with PB970055 only.
1 PB12767 58.51
Brass Pre-Assembled Manifold Control Pack
PackQty.
Code No.
Price Each £
Factory assembled UFCH Control Pack - Includes EUP Pump, UFCH Mixer Valve, bend and adaptors. For use with Brass Manifolds only (see page 30-31).
1 PB970035 404.34
High Limit Thermostat PackQty.
Code No.
Price Each £
Provides additional protection from high temperature water. For use with PB970035.
1 PB970036 25.08
Brass Pre-Assembled Manifold Control Pack
PackQty.
Code No.
Price Each £
Factory assembled UFCH Control Pack - Includes EUP Pump, UFCH Mixer Valve, bend and adaptors. For use with Polymer Manifolds only (see page 28-29).
1 UFHPPP1 328.84
2 Port Zone Valve PackQty.
Code No.
Price Each £
New 2 Port Spring Return Zone Valve (pictured) 1 UFH2PORTZV 67.40
Water Temperature Controls and Accessories
www.polypipeufh.com32
The new Single Zone Electric Boiler means that underfloor
heating can now be installed as a standalone system -
removing the need to plumb into the existing heating system.
• 3kw Heating Element
• 2 Port Push Fit Manifold
• Internal Pump
• Expansion
• Pressure Relief
• Pressure Guage
• Filling Connections
• Air Vent
UFCH Mixing Valve PackQty.
Code No.
Price Each £
22mm 1 PB219058 130.01
28mm 1 PB219059 145.11
Single Room SystemsSingle Room Control UnitsZonal Regulation Units (ZRU)
PackQty.
Code No.
Price Each £
ZRU Single circuit 1 PB970018 458.07
Single Room Control UnitsZonal Regulation Units (ZRU)
PackQty.
Code No.
Price Each £
ZRU 2/3 circuit 1 PB970028 476.04
Temperature Limiting Valve PackQty.
Code No.
Price Each £
Temperature Limiting Valve 5m2 Overlay™ only 1 PB970010 74.20
Magnetic Filter PackQty.
Code No.
Price Each £
MagnaClean TwinTec Magentic Filter 1 UFHFILTER 180.00
www.polypipeufh.com 33
Water Temperature Controls and Accessories
NEW Single Zone Electric Boiler (see page 45)
UFHEHU
www.polypipeufh.com34
Replacement Washer PackQty.
Code No.
Price Each £
1” Fibre washer 1 UFHWASHER 0.46
Replacement UFH Pump PackQty.
Code No.
Price Each £
Replacement UFH Pump 1 PB970026 233.21
Replacement Mixing Valve PackQty.
Code No.
Price Each £
Mixing Valve for PB970055 (Steel Pump Pack) 1 PB970059 232.39
Replacement Mixing Valve PackQty.
Code No.
Price Each £
Mixing Valve for UFHPPP1 (Polymer Pump Pack) 1 UFHPPPRV 225.26
Replacement Zone Valve Head
PackQty.
Code No.
Price Each £
Replacement 2 Port Steel Zone Valve Head 1 UFHZVACT 59.72
Spares and Ancillaries
Replacement Zone Valve Head
PackQty.
Code No.
Price Each £
Replacement 2 Port Zone Valve Head 1 UFHZVHEAD 59.72
Replacement Modulating Pump Valve
PackQty.
Code No.
Price Each £
Replacement Modulating Pump Valve 1 PB970014RV 172.20
Replacement Mixing Valve PackQty.
Code No.
Price Each £
Mixing Valve for PB970035 (Brass Pump Pack) 1 PB970039 225.26
UFCH Valve Actuator PackQty.
Code No.
Price Each £
2 Wire 1 PB00401/1 26.61
Spares and Ancillaries
www.polypipeufh.com34
ONLY WHILE
STOCKSLAST
www.polypipeufh.com 35
The range is designed to enable users to configure their heating system to create their preferred balance of comfort and efficiency. Unique programming functions also provide the perfect control solution for Polypipe Underfloor Heating Systems.
Polypipe Room Temperature Controls are available in a wide range of options, including dial, digital, programmable and internet room thermostats, in both wired and RF version, time clocks and master and slave systems.
Use our online controls selector tool for help with selecting the right controls system at www.polypipeufh.com
Polypipe supplies a comprehensive range of room temperature control products for use on both Polypipe Underfloor Heating Systems and for general use to control heating temperatures in different rooms or control zones. Now with internet control options.
Room Temperature Controls
www.polypipeufh.com36
Room Temperature Controls
UFCH Valve Actuators PackQty.
Code No.
Price Each £
2 Wire 1 PB00401 26.61
4 Wire 1 PB00402 44.32
Room Thermostats PackQty.
Code No.
Price Each £
Dial Room Thermostat 1 UFHDIALW 40.45
Programmable Room Thermostat 1 UFHPROGW 64.20
Smart Programmable Room Thermostat 1 UFHSMARTW 90.95
Smart Programmable Room Thermostat RF 1 UFHSMARTRFW 101.65
Time Clocks PackQty.
Code No.
Price Each £
4 Channel Time Clock 1 UFHTIME4W 89.87
Ancillaries PackQty.
Code No.
Price Each £
Wifi Connectivity Internet Hub 1 UFHWIFIHUBW 203.30
Single Zone Floor Sensor includes 2.95m cable 1 UFHFLOORW 10.88
Single Zone Thimble Sensor 1 UFHTHIMW 23.54
RF Remote Boiler Switch 1 UFHBSW 69.55
Smart Plug 1 UFHSPLUGW 58.85
Wiring Centres
For wired room thermostats and clocks
PackQty.
Code No.
Price Each £
4 Zone Wiring Centre - Provides wiring connections for Boiler, Zone Valve, UFH Pump and Power Supply for 4 Room Thermostats
1 UFH4ZW 85.60
8 Zone Wiring Centre - Provides wiring connections for Boiler, Zone Valve, UFH Pump and Power Supply for 8 Room Thermostats
1 UFH8ZW 107.00
Wiring Centres
For RF Room Thermostats and Clocks
PackQty.
Code No.
Price Each £
8 Zone RF Wiring Centre - Provides wiring connections for Boiler, Zone Valve, UFH Pump and Provides RF Connectivity for up to 8 Thermostats
1 UFH8ZRFW 181.90
Wet Room SensorUse UFHSBOXW and UFHFLOORW for a complete Wet Room Sensor
PackQty.
Code No.
Price Each £
Wet Room Sensor Box (to be used in conjunction with UFHFLOORW)
1 UFHSBOXW 5.35
Single Zone Floor Sensor (to be used in conjunction with UFHSBOXW to create one Wet Room Sensor)
1 UFHFLOORW 10.88
www.polypipeufh.com 37
Room Temperature Controls
Room Thermostats PackQty.
Code No.
Price Each £
Dial Room Thermostat 1 UFHDIALB 40.45
Dial Room Thermostat RF 1 UFHDIALRFB 58.42
Programmable Room Thermostat 1 UFHPROGB 75.32
Programmable Room Thermostat RF 1 UFHPROGRFB 103.34
Time Clocks PackQty.
Code No.
Price Each £
2 Channel 1 UFHTIME2B 58.51
4 Channel RF 1 UFHTIME4RFB 89.87
www.polypipeufh.com38
Room Temperature ControlsONLY WHILE
STOCKSLAST
Wiring Centres
For wired room thermostats and clocks
PackQty.
Code No.
Price Each £
Single Zone Master Control Unit - Provides wiring connections for Boiler, Zone Valve, UFH Pump and Power Supply and Single Room Thermostat
1 PB1ZM 82.49
4 Zone Slave Unit - Plug-in connection to Master Unit to provide 4 Control Zones
1 PB4ZS 71.90
6 Zone Slave Unit - Plug-in connection to Master Unit to provide 6 Control Zones
1 PB6ZS 87.33
Wiring Centres
For RF Room Thermostats and Clocks
PackQty.
Code No.
Price Each £
2 Zone Master Unit - Provides hard wired connections for Boiler, Zone Valve, UFH pump, power supply and Actuators (2 zone). Provides RF Connectivity for RF Clock and up to 2 RF Thermostats.
1 PB2ZM RF 179.71
4 Zone Slave Unit RF - Plug in connection to PB2ZM RF and provides RF connectivity for up to 4 Zones
1 PB4ZS RF 89.87
RF Receiver - Remote RF receiver providing connectivity to any RF Thermostat or time clock (switches 230V)
1 PB REC RF 40.45
Wet Room Sensor PackQty.
Code No.
Price Each £
Includes 3m Sensor Cable - Connects to all wired and RF Room Thermostats for remote sensing in wet rooms
1 PB23020 10.88
www.polypipeufh.com 39
Room Temperature Controls
ONLY WHILE
STOCKSLAST
Smart Plus Controls Wiring Centre
PackQty.
Code No.
Price Each £
8 Zone Master Unit for RF Pairing. 1 UFH8ZMP 370.16
Smart Plus Controls Thermostats
PackQty.
Code No.
Price Each £
8 Zone Master TFT Thermostatic Control Unit 1 UFHTFTMBP
(Black) 370.16
8 Zone Master TFT Thermostatic Control Unit 1 UFHTFTMWP
(White) 370.16
Single Zone TFT Thermostatic Control Unit 1 UFHTFTBP
(Black) 370.16
Single Zone TFT Thermostatic Control Unit 1 UFHTFTWP
(White) 370.16
Single Zone Temperature Sensor with Boost Function(White)
1 UFHBOOSTWP 74.29
Single Zone Temperature Sensor with Boost Function (Battery Operated)
1 UFHBBOOSTWP 74.29
Single Zone Temperature Sensor (Black)(Battery Operated)
1 UFHSENSEBP 39.80
Single Zone Temperature Sensor (White)(Battery Operated)
1 UFHSENSEWP 39.80
Single Zone Mini Sensor (White)(Battery Operated)
1 UFHCMINIP 36.89
Single Zone Floor Sensor (White)(Battery Operated)
1 UFHFLRWP 36.89
www.polypipeufh.com40
Room Temperature Controls
www.polypipeufh.com 41
Smart Plus Internet Connectivity Modules
PackQty.
Code No.
Price Each £
Wifi Connectivity Internet Module 1 UFHINTWIFIP 298.53
Hard Wired Internet Module 1 UFHINTMODP 260.03
Remote Boiler Switch 1 UFHRBSP 95.23
Smart Plus Radiator Controls PackQty.
Code No.
Price Each £
Remote TRV 1 UFHTRVP 82.39
Central Radiator Controller 1 UFHINTRADP 239.78
Accessories PackQty.
Code No.
Price Each £
Additional Power Connection Unit 1 UFHPOWERP 37.15
www.polypipeufh.com 41
Room Temperature Controls
This range of underfloor heating packs contains all the flooring and control equipment required for a single room project.
1. Select the floor type applicable for the room from the following options:
Solid Floor – Red Floor Panel (Code SO) Solid Floor - Staple (Code SS)Overlay™ (Code O) Overlay™ Lite (Code OL)
2. Select the total heated floor area for the room and round up to the following options:
*5m² (Code 5) 12m² (Code 12) 20m² (Code 20) 30m² (Code 30)
3. Add the control unit:
ZRU – For connection to existing heating system (Code Z) *Temperature Limiting Valve – For connection to existing heating systems in rooms up to 5m² (Code B)
4. Optional Room Thermostatic control:
ZRU only (No additional code) Wired Dial Thermostat (Code C) RF Dial Thermostat (Code RF)
EXAMPLE:The order code for a 12m2 solid floor with a ZRU would be:
*Overlay™ only
SS
Solid Floor Staple
20
20m2
Z RF SS20ZRF
ZRU RF Thermostat
Order Code
www.polypipeufh.com42
High Output Room Packs
Pack number Floor Type Area List Price (Thermostat option)
None Wired (C) RF (RF)
O5B Overlay™ 5m² £435.99 - -
O12Z Overlay™ 12m² £1,218.45 £1,281.14 £1,336.87
O20Z Overlay™ 20m² £1,623.20 £1,685.90 £1,741.62
O30Z Overlay™ 30m² £2,127.99 £2,190.69 £2,246.40
OL12Z Overlay™ Lite 12m² £1,186.91 £1,249.59 £1,305.33
OL20Z Overlay™ Lite 20m² £1,647.30 £1,709.98 £1,765.70
OL30Z Overlay™ Lite 30m² £2,110.39 £2,173.08 £2,228.81
SO12Z Red Floor Panel 12m² £811.57 £874.25 £929.99
SO20Z Red Floor Panel 20m² £1,063.60 £1,126.29 £1,182.01
SO30Z Red Floor Panel 30m² £1,366.41 £1,429.10 £1,484.82
SS12Z Staple System 12m² £732.05 £794.74 £850.46
SS20Z Staple System 20m² £944.71 £1,007.41 £1,063.13
SS30Z Staple System 30m² £1,147.14 £1,209.82 £1,265.55
Please Note: Wired control option adds 1 x UFHDIALB RF Control option adds 1 x UFHDIALRFB and 1 x PBRECRF Receiver.
www.polypipeufh.com 43
High Output Room Packs
Room Packs Pack Code
Pack Code
Pack Code
Pack Code
Overlay™ Single Room Packs O5B O12Z O20Z O30Z
Product Qty Qty Qty Qty
Overlay™ Temperature Limiting Valve 1
Overlay™ Panel (in Packs of 10) 10 10
Overlay™ Panel (in Packs of 30) 30 30 60
Overlay™ End Returns (in Packs of 10) 10 20 40 60
Overlay™ Pipe (12mm x 80m) 1 1 2 3
Overlay™ Glue 1 1 2 2
12 x 15mm Adaptors (in Packs of 2) 2 2 4 6
15mm PolyPlumb Tees 2 4
15mm PolyPlumb Spigot Elbows 2 4
ZRU (Zonal Regulation Unit) 1 1 1
Overlay™ Lite Single Room Packs OL12Z OL20Z OL30Z
Product Qty Qty Qty
Overlay™ Lite Panel (in Packs of 10) 10
Overlay™ Lite Panel (in Packs of 20) 20 20 40
Overlay™ End Returns (in Packs of 10) 20 40 60
Overlay™ Pipe (12mm x 80m) 1 2 3
Self Adhesive Aluminium Tape 1 2 2
12 x 15mm Adaptors (in Packs of 2) 2 4 6
15mm PolyPlumb Tees 2 4
15mm PolyPlumb Spigot Elbows 2 4
ZRU (Zonal Regulation Unit) 1 1 1
Solid Floor 12m² 20m² 30m²
Product So SS So SS So SS
Screeded Solid Floor Panels 12 20 30
60mm Staple Clips (in Packs of 300) 300 600 600
15mm x 100m Pipe Coil 1 1 2 2 3 3
Edge Expansion 1 1 1 1 2 2
Pipe Stiffeners (in Packs of 30) 30 30 30 30 30 30
15mm PolyPlumb Tees 2 2 4 4
15mm PolyPlumb Spigot Elbows 2 2 4 4
ZRU (Zonal Regulation Unit) 1 1 1 1 1 1
Optional Extras:
Standard output room packs are designed to work systematically with your current central heating system. If you require independent control of your underfloor heating, you will need the following products:
1. One programmable room thermostat (UFHPROGW)
2. One zone value (UFH2PORTZV)
UFHROOM34
Up to 34m2 Product Qty List Price (each)
25m Edge Expansion PB05855 2 £29.25Conduit Pipe Coil 15mm x 25m UFHCP1525 1 £24.54
UFCH Staple Clip (60mm) PB2930 300 £0.14
15mm x 80m Coil UFH Pipe UFH8015B 2 £116.45
15mm UFH Pipe Stiffener UFHPS15 4 £0.31
ZRU 2/3 Curcuit PB970028 1 £476.04
Total List Price £835.22
UFHROOM21
Up to 21m2 Product Qty List Price (each)
25m Edge Expansion PB05855 1 £29.25Conduit Pipe Coil 15mm x 25m UFHCP1525 1 £24.54
UFCH Staple Clip (60mm) PB2930 300 £0.14
15mm x 100m Coil UFH Pipe UFH10015B 1 £145.56
15mm UFH Pipe Stiffener UFHPS15 2 £0.31
ZRU Single Curcuit PB970018 1 £458.07
Total List Price £700.04
UFHROOM10
Up to 10m2 Product Qty List Price (each)
25m Edge Expansion PB05855 1 £29.25Conduit Pipe Coil 15mm x 25m UFHCP1525 1 £24.54
UFCH Staple Clip (60mm) PB2930 300 £0.14
15mm x 50m Coil UFH Pipe UFH5015B 1 £72.78
15mm UFH Pipe Stiffener UFHPS15 2 £0.31
ZRU Single Curcuit PB970018 1 £458.07
Total List Price £627.26
Standard Output Room Packs(200mm Pipe Spacing)
www.polypipeufh.com44
Heat Generation PackQty.
Code No.
Price Each £
3kw Single Zone Electric Boiler for Underfloor Heating
1 UFHEHU 900.00
Heat Generation
www.polypipeufh.com 45
www.totallyplumbing.com00
These systems meet the growing demand for products that are suitable for renewable heat sources such as remote boilers and heat pumps. Installation is fast and easy, requiring just a single lay of the flow and return pipes, which are both contained in a single casing. The inner water bearing pipes are PEX barrier pipes, which are contained in a corrugated HDPE outer casing.
Polypipe pre-insulated pipes are fastened using brass mechanical clamp fittings, which require no special tools or equipment.
Polypipe offers a range of pre-insulated pipe systems, which provide flexibility, durability and availability when required.
Renewable Pipe Systems
www.polypipeufh.com46
www.totallyplumbing.com 00
Pre-Insulated PipesPre-Insulated Pack (pack contains pre-cut double PEX-a pipes in 140mm outer casing, two dust end caps, four male couplings and four fix points)
PackQty.
Code No.
Price Each £
25mm. 10m Twin Pipe Coil Pack 2mm x 25mm (OD) 20DN (ID). 1 PRE1025-HTG 400.48
25mm. 15m Twin Pipe Coil Pack 2mm x 25mm (OD) 20DN (ID). 1 PRE1525-HTG 556.24
25mm. 20m Twin Pipe Coil Pack 2mm x 25mm (OD) 20DN (ID). 1 PRE2025-HTG 741.63
32mm. 10m Twin Pipe Coil Pack 2mm x 32mm (OD) 25DN (ID). 1 PRE1032-HTG 502.39
32mm. 15m Twin Pipe Coil Pack 2mm x 32mm (OD) 25DN (ID). 1 PRE1532-HTG 655.31
32mm. 20m Twin Pipe Coil Pack 2mm x 32mm (OD) 25DN (ID). 1 PRE2032-HTG 783.74
Dust Cap PackQty.
Code No.
Price Each £
140mm x 25mm Dust Cap 1 INS140-25-2DC 10.91140mm x 32mm Dust Cap 1 INS140-32-2DC 10.91
Heat Shrink Cap PackQty.
Code No.
Price Each £
140mm x 25mm Dust Cap 1 INS140-25-2HSC 109.72140mm x 25mm Dust Cap 1 INS140-32-2HSC 109.72
Male Couplings
For PEX pipe
PackQty.
Code No.
Price Each £
25mm (OD)/2.3 (w/t) thread ¾” 1 INS25MC-HTG 25.9732mm (OD)/2.9 (w/t) thread 1” 1 INS32MC-HTG 34.05
CouplingsFor PEX pipe to PEX pipe
PackQty.
Code No.
Price Each £
25mm x 25mm coupling 1 INS25FC-HTG 52.00
32mm x 32mm coupling 1 INS32FC-HTG 68.10
Fix Points PackQty.
Code No.
Price Each £
25mm, thread ¾” FF 1 INS25FP-HTG 9.1532mm, thread 1” FF 1 INS32FP-HTG 20.79
New range available May 2020
Renewable Pipe Systems
Max operating pressure: 6 bar. Max fluid temperature: +95oC. PE-Xa pipes: SDR 11.
Carrier pipes are individually identified as flow (red) and return (blue).
www.polypipeufh.com 47
Standards & Polypipe Guarantee InformationPolypipe meets, and constantly strives to exceed, the changing laws and regulations governing our operations and products. We have invested in extensive testing and development facilities to ensure the products we supply are of the highest quality. Our plumbing systems conform to a number of third party accredited standards which are listed below.
British Standard Class S rated to BS7291 Part 1 and Kitemark Licence Number 38148 to BS7291 Part 1 & 2.
PolyPlumb, PolyMax and PolyFit barrier pipe systems are covered by BBA Certificate No 00/3699.
Listed in the WRAS Water Fittings and Materials Directory.
Standards Manufacturing Quality Assurance - in accordance with BS EN ISO 9001 (BSI registered firm Certificate FM00318).
British Gas has accepted the Polypipe ‘PolyPlumb’ & ‘PolyFit’ Class S polybutylene pipe systems as being acceptable for open vented and sealed central heating systems and are eligible for acceptance onto Home Care Central Heating System Cover.
At Polypipe we pride ourselves on offering the highest quality products, and wherever possible our products and processes are covered by independent third-party accreditation, so you can rest easy knowing that you are buying from the UK’s market leading manufacturer. We have invested significantly in our quality control procedures, have our own fully-equipped modern laboratory for development and analysis, and also have our own tooling and extrusion processes.
Installation Standard
Installation must follow the requirements of BS5955 - PART 8 2001 Plastic Pipework (Thermoplastic Materials).
Guarantee
Polypipe guarantees for 25 years against defects in materials or manufacture of the PolyPlumb, PolyMax and PolyFit hot and cold water supply and heating systems from date purchased. Underfloor heating pipe for 50 years and all other UFH component parts (including Manifolds, controls and accessories) for 2 years.
This guarantee only applies if the products are installed in accordance with the manufacturer’s recommendations and are used in a normal domestic operation.
A normal domestic operation is defined as a residential property and excludes commercially run residential properties e.g. care homes and is also defined as being part of an open vented or sealed central heating system, direct or indirect single pipe hot water supply or mains or tank fed cold water supply system.
The system must be designed, installed and operated within the temperature and pressure ratings as defined in BS 7291 Class S which are also published in the manufacturer’s literature and must also take account of all the other exclusions and limitations as defined in the design, application and installation guidance provided by the manufacturer.
Exclusions apply, please contact the manufacturer for further details.
For Polypipe’s Contract of Sale, please refer to www.polypipe.com
FM 00318
APPROVALINSPECTIONTESTINGCERTIFICATION
CERTIFICATE 00/3699
Standards & Polypipe Guarantee Information
www.polypipeufh.com48
Underfloor Heating Pipe (UFH) and MCP Underfloor Heating Pipe (MCP) - Application ClassesThe Polypipe UFH and MCP Underfloor Heating Pipes have been tested in accordance with BS EN ISO 15876-1:2003 and BS EN ISO 21003-1:2008 respectively at a maximum design pressure of 10 bar for application class 4 - Underfloor heating and low-temperature radiators only. The maximum operating temperature of these pipes is 60°C.
These pipes are NOT suitable for potable cold water or domestic hot water services.
The following information is designed to provide basic guidance for installers and specifiers when selecting Polypipe products. The information is not exhaustive and guidance may change dependent on site conditions and applications. This document should be read in conjunction with the Polypipe Plumbing & Heating Product Guide. If in doubt please contact our Technical Services Department on +44 (0) 1709 770000.
Service ConditionsGrey and White Plumbing and Heating Pipe, PolyPlumb, PolyMax, PolyFit and PolySure fittings are suitable for the following Class S service conditions in a normal domestic operation (subject to the exceptions referred to in note 2):
(Continuously operated ring main installations are excluded from these applications.)
Indirect cold water systems 20
82
82
65
65
60
20
3½
3
3½
6
3½
3½
12½
-
114
100
100
100
100
-
20
105
95
95
83
83
20
Subsurface heating systems(including underfloor)
Vented hot water supply systems
Unvented hot water supplysystems including instantaneousheaters and/or incorporatingstorage
Direct mains-fed cold water systems
Vented central heating systems
Sealed central heating systems
(see
exp
lana
tory
Not
e 1)
tem
pera
ture
Tf °
C
Nom
inal
sys
tem
flow
(see
exp
lana
tory
Not
e 1)
tem
pera
ture
Ts °
C
Max
imum
sys
tem
ser
vice
(s
ee e
xpla
nato
ry N
ote
1)
tem
pera
ture
Tm
°C
Syst
em m
alfu
nctio
nw
orki
ng p
ress
ure
bar
Syst
em m
axim
um
Application Information
www.polypipeufh.com 49
Note 1: • nominal system flow temperature Tf is the intended maximum flow temperature of a system for a particular
application as recommended in codes of practice and other guidance documents
• maximum system service temperature Ts is the maximum service temperature that can occur intermittently during normal operation
• system malfunction temperature Tm is the maximum temperature likely to be applied to pipes and fittings in the event of control thermostat failure or malfunction
Note 2:
• certain fittings in the PolyPlumb, PolyMax and PolyFit ranges are not suitable for all the Class S service conditions. The limitations are indicated against every applicable fitting in the Trade Price List e.g. “Cold Water Only”.
REACH DeclarationOn 27 June 2018, lead metal (CAS 7439-92-1) was added to the REACH candidate list. According to the article 33 of the regulation 1907/2006, we herewith inform you that brass products we supply may contain lead or lead impurities in quantities above 0.1% by weight.
Connections to other materialsConnection to Imperial Copper using PolyPlumb
Imperial ¾” copper pipe is of significantly different size to its metric 22mm counterpart and therefore requires a different ‘O’ ring to that supplied in the 22mm fitting. The 22mm ‘O’ ring should be replaced with a ¾” ‘O’ ring (PB9034). Standard 15mm fittings can be connected to Imperial ½” copper pipe, and 28mm fittings can be connected to 1” copper pipe.
Connection to Irish copper pipe
Irish copper pipe to IS238:1980 can be connected to PolyPlumb fittings which incorporate the ¾” or 1” adaptor set. Using a standard 22mm or 28mm PolyPlumb fitting, remove the nut and socket components and discard. Replace these parts with the relevant adaptor set, ¾” - PB7034 or 1” - PB701. The adaptor sets are distinguishable by the black cap nut.
Connections to chrome plated and stainless steel pipework
PolyPlumb, PolyFit and PolyMax fittings should not be connected directly to chrome plated copper pipes or stainless steel pipes. To connect to these pipes we recommend the use of a compression coupler. A pipe stiffener should be used when connecting Polypipe Grey and Polypipe White pipe to a compression fitting.
Connecting PolySure press-fit fittings to copper
PolySure press-fit fittings have been designed specifically to fit to Polypipe grey and Polypipe white polybutylene pipes. To connect to copper pipes we advise the use of a PolySure press-fit x BSP male or female adaptor, with the corresponding adaptor being used on the copper side from the PolyPlumb or PolyFit range. PTFE tape should be used to seal the mating brass components.
Connections close to capillary fittings
Capillary fittings should preferably be completed prior to the use of Polypipe fittings. Where this is not possible, care should be taken to ensure that flux or solder does not come into contact with plastic pipes or fittings. A damp cloth should be wrapped around the copper pipe close to the nearest plastic pipe or fitting to ensure against damage by conductive heat. Pipework should be flushed to clear flux before active use.
Application Information
www.polypipeufh.com50
Connections to incoming cold water supply
There are two options for connecting incoming MDPE mains water service pipe to Polypipe Plumbing and Heating Systems. Firstly the push-fit x compression adaptors provide a one piece transition fitting covering connections from 20mm, 25mm and 32mm MDPE service pipes to 15mm, 22mm and 28mm polybutylene pipes and most sizes are available in both Polypipe Grey and White versions. Secondly, as there is a requirement for a stopcock on the incoming main there is also a combined stopcock and adaptor which reduces the number of fittings required in a position where there is often limited space e.g. under a kitchen sink. These products allow connections from 20mm or 25mm MDPE pipe via a compression end to 15mm or 22mm polybutylene using a push-fit connection.
Gas, oil, and compressed airPolypipe systems are suitable for domestic plumbing and heating systems. Pipes and fittings must not be used for gas and oil supply pipework or compressed air pipework. In all the above instances metal pipework should be installed.
Continuously operated re-circulating systems (Secondary Hot Water Circulation/Ring main installations)A continuously operated re-circulating system is a water-replenished circulating system which is maintained at a constant high temperature to provide a constant source of hot water. Continuously operated re-circulating systems are used to distribute constant hot water to wards or rooms that may be distant from the heat source or hot water storage vessel. Locations where continuously operated re-circulating systems are used include, but are not limited to, residential care homes, hospitals and hotels. Continuously operated re-circulating systems are very different from conventional hot water supply and central heating systems found in domestic properties, for which our products have been tested to, under either BS 7291 Class S or WRAS approval standards, and for this reason PolyPlumb, PolyMax, PolyFit or PolySure must not be used on any continuously operated re-circulating systems. Some secondary hot water circulation systems are used intermittently, controlled by time and/or temperature thermostats. This application is also unsuitable for products manufactured to BS 7291.
Re-cycled rainwater systems
Polypipe products can be used in systems conveying re-cycled or harvested rainwater within domestic properties. All pipework used in this type of system should be clearly identifiable and this should be carried out in accordance with WRAS Information and Guidance Note No 9-02-05; Marking and Identification of Pipework for Reclaimed (Greywater) Systems. If self adhesive labels are to be used, these should not be applied directly to the pipe.
Application Information
www.polypipeufh.com 51
Chlorine and other additives
The polybutylene material used in Polypipe Plumbing and Heating Systems is WRAS approved. It is resistant to the buildup of scale. Normal levels of chlorine in UK domestic water supplies will not have an adverse effect on Polypipe Plumbing and Heating Systems.
However, Polypipe Plumbing and Heating Systems are not suitable for systems in which any further additives are ever added, periodically added, or regularly dosed into or additional to the normal UK mains water supply, for example chlorine for swimming pools or those used for bacteria control or Legionella prevention. Systems must not be flushed through with anything other than water from the normal UK mains water supply or a cleaning product at the correct concentration that is specifically recommended for plastic piping systems.
The use of corrosion inhibitor in central heating systems is acceptable provided that the inhibitor is specifically designed for plastic piping systems and guidance on their suitability should be sought from the inhibitor manufacturer prior to adding to the system.
Electrical Safety / Equipotential Bonding
Where Polypipe pipes break the continuity of existing metal pipe, which may be used for earthing or bonding, this continuity must be re-instated by affixing permanent earth clips and a section of earth cable between the copper ends on either side of the plastic sections. Both the IEE and the Chartered Institute of Plumbing and Heating Engineers now give guidance on the Earth Bonding requirements of Plastic Pipe systems. As plastic pipes do not conduct electricity, installations generally require less equipotential bonding than metal systems although if in doubt exact guidance should be sought.
Light
Polypipe Plumbing and Heating Systems should be protected from UV light. Standard decorating paints form adequate protection. Pipe insulation forms adequate protection for external use. Polypipe products are delivered in light protective packaging.
Compatibility with other substances
For details of compatibility with building and cleaning substances, and treatments (e.g. filler foam and wood worm treatments) please consult the relevant manufacturers to confirm suitability with polybutylene. Polypipe Plumbing and Heating Systems pipes and fittings can be painted using emulsion or undercoat and gloss. Cellulose based paints, strippers or thinners must not be used.
Vermin
There is no evidence to suggest that Polypipe Plumbing and Heating Systems attract vermin. Where vermin are present they can cause damage to other services, building fabric and pipes and fittings, and therefore a qualified pest controller should be employed to remove vermin from the affected area.
Application Information
www.polypipeufh.com52
Connections to other equipmentBoilers and appliances:
All boilers and appliances must have safety devices such as thermostatic controls, cut-outs and pump over-run protection to make sure that they cannot operate above the Class S working temperature and pressure limits set out in the table of Class S service conditions above. Exposure to conditions in excess of those specified could result in failure of the pipes or fittings with the potential for serious injury.
Gas Boilers:
Pipe should only be connected to gas boilers where the pipe connection is outside the boiler casing and where the boiler incorporates a high limit thermostat and pump over-run facility. The pipe connections should be 350mm from the heat source. In all other situations, a section of metal pipe should be at least 1m in length. In addition for back boilers metal pipework should be used within the fire opening extending out of the chimney brickwork.
Combination Boilers:
Where system connections are made to an incoming water supply pipe from a water meter, or any other device which contains a check valve, a suitable expansion vessel must be fitted to prevent the expansion of heated water back down the supply pipe. This is especially important where a water meter is fitted retrospectively.
Solid Fuel Boilers & Cooking Ranges
Pipes and fittings must not be used for primary or gravity circuits from solid fuel boilers, cooking ranges or other uncontrolled heat sources.
Solar Panels / Systems
Pipes and fittings must not be used for connection of solar panels or any part of solar distribution that operates above the Class S working temperature and pressure limits set out in the table of Class S service conditions above.
Application Information
www.polypipeufh.com 53
Oil Fired Boilers
Open Vented Central Heating Systems:
The use of plastic pipe and fittings is acceptable when used in oil fired installations where the boiler is connected to an open vented system, however the first metre of primary pipework from the boiler connections must be installed using metal pipe. The boiler must be suitable for this type of application and all relevant safety features as supplied and fitted to the boiler must be checked for correct operation. The system must also be commissioned in accordance with the boiler manufacturers instructions.
Plastic pipe and fittings can also be used in the hot and cold water and underfloor central heating systems with the exception of continuously operated re-circulating systems (see page 50) where plastic pipe and fittings should not be used.
For further information regarding the suitable applications for our plastic pipe and fittings please refer to the Class S Service Conditions table as shown on page 48 of this publication.
Sealed Central Heating Systems:
Where a sealed system oil fired boiler is to be used, all primary boiler pipework to and from the hot water cylinder (if fitted) and any radiator or towel rail circuits must be installed using metal pipe and fittings.
Plastic pipes can be used on underfloor central heating systems where the plastic pipes are fitted after the UFCH control unit and manifold arrangement which must contain a correctly operating thermostatic mixing valve.
Plastic pipe and fittings can also be used in the hot and cold water system with the exception of continuously operated re-circulating systems (see page 50), where plastic pipe and fittings should not be used.
All relevant safety features as supplied and fitted to the boiler, such as the boiler temperature control thermostat, high limit thermostat, pump overrun facility and the pressure and temperature relief valve, must be checked for correct operation at both installation stage and at any subsequent boiler service intervals. The system must also be commissioned in accordance with the boiler manufacturers instructions.
For further information regarding the suitable applications for our plastic pipe and fittings please refer to the Class S Service Conditions table as shown on page 48 of this publication.
Application Information
www.polypipeufh.com54
Use of aluminium tapeTo comply with the NHBC guidelines regarding detection of pipes in wall cavities Polypipe recommends the use of aluminium tape. This tape should be applied directly to the wall sub-structure and pipes should be clipped on top of the tape. The tape must not be applied directly to the pipes.
“Dot and dab” wallingDry lined or “dot and dab” walls are commonly used to speed up the build process and Polypipe systems are compatible with these types of constructions. Board adhesive or plaster should not be applied to Polypipe pipe and fittings, especially around the area where the pipes pass through the wall to feed radiators and appliances. Pipes and fittings must remain accessible should future maintenance be required.
Handling and storage of productsThe packaging of both pipes and fittings is designed to protect from ultraviolet light and environmental contamination. Pipes and fittings should therefore be retained in their packaging as long as possible, and should be stored in a cool dry area.
When on site, fittings should be stored to prevent dust and debris from entering the fitting and sticking to the pre-lubricated ‘O’ ring. Care should be taken to avoid scratching the pipe surface during the handling, storage and installation processes.
Insulation of pipeworkIf pipe and fittings are installed in an environment that is not heated or alternatively outside, they should be protected from potential frost damage in accordance with BS6700 and BS5422.
Pipe SupportAll pipes should be correctly supported using either nail-in, snap-fit or bull dog clips. Where required spacer pieces are available for the snap-fit clips. All pumps and valves must be correctly supported to prevent unnecessary strain on the pipework.
Where plastic pipework is exposed it should be installed at the fixings centres below:
10mm & 15mm, horizontal 0.3m, vertical 0.5m 22mm, horizontal 0.5m, vertical 0.8m 28mm, horizontal 0.8m, vertical 1.0m
Concealed plastic pipes may be supported at greater centres provided the sagging is not excessive. Pipes spanning between joists at up to 600mm centres are normally acceptable for concealed pipework. The use of cable ties is permissible for concealed pipework. Cable ties should not be over tightened.
Drilling of holes/thermal expansionHoles drilled in joists should be large enough to allow for the thermal movement of the pipe. Space should also be left between joists and fittings to accommodate thermal expansion and also for access to the sockets, should this be required.
Application Information
www.polypipeufh.com 55
Steel framed constructionDamage to the outside of the pipe when cabling through metal joists/struts/webs, etc. must be avoided. Pipe runs should be made through pre-made holes where possible. The use ofrubber or plastic grommets is recommended.
System testingPressure testing of the pipe system is essential however a successful pressure test using the following steps is not a guarantee of complete and correct installation and only ensures that pipes have been inserted into fittings passed both the ‘O’ ring and the grab ring. If pipes have been scored or scratched during the installation process a high pressure test as below may not highlight these issues.
1st fix Installations
Step 1:
Pipe and fittings only should be tested. The system should be filled completely using water not more than 20°C at a test pressure of 18 bar which should be applied for not less than 15 minutes and no longer than 1 hour. Joint security can be checked visually and by tugging at joints.
2nd fix Installations
Step 2:
Complete installations including appliances should be tested with water to the maximum pressure allowed by the manufacturers of the appliances and fittings. Please note, due to Health and Safety reasons pipework installations must not be air tested.
Pressure testing in sub zero temperatures
Special precautions are necessary if the pressure testing is to take place in sub-zero temperatures.
This applies particularly in underfloor central heating systems using the screeded floor system where most of the pipe is encased in concrete. Due to the contact between pipe and floor panel on screeded installations, where the screed does not completely surround the pipe, there may be points where strain is created on the pipe in freezing conditions which is not normally present.
Therefore it is advisable to drain the underfloor central heating system once testing and screeding has been completed.
Precautions should also be taken where installations contain large quantities of fittings which due to the rigidity of their construction may put undue pressure on the pipe.
Application Information
www.polypipeufh.com56
Notes
www.polypipeufh.com 57
Polypipe Underfloor HeatingTrade Price List 2020
Polypipe Ulster
Dromore Rd, Lurgan Craigavon, Co. Armagh BT66 7HL, UK
T: +44 (0) 28 38 881270 F: +44 (0) 28 38 882344
Polypipe Building Products
2410 London Road, Mount Vernon, Glasgow G32 8XZ, UK
T: +44 (0) 141 778 8822 F: +44 (0) 141 778 2703
Polypipe Building Products
Broomhouse Lane, Edlington, Doncaster DN12 1ES, UK T: +44 (0) 1709 770000 F: +44 (0) 1709 770001www.twitter.com/polypipetrade
www.facebook.com/polypipetrade
www.instagram.com/polypipetrade
FOLLOW US ON