P&M Line list

Embed Size (px)

Citation preview

  • 8/8/2019 P&M Line list

    1/16

    Operating Instruction for Weighing Meter K3NV

    Page1

    MCI 70-N

    Reset

    / Teach

    Reset

    / Teach

    The following symbols were used through out the chapter for easy setting of parameters.

    - Mode Key - Press briefly the mode key single time.

    1Sec - - Press the mode key for about 1 second.

    - Shift Key - Press briefly the shift key single time.

    - Up Key - Using the Up Key select the desired data.

    - - Using the Up and Shift key select the desired data.

    - Escape Key - Press briefly the Esc key single time.

    - Reset / Teach - Press briefly the Reset/Teach key single time.

    1Sec - - Press the Reset/Teach key for about 1 second.

    + - - Press both the Esc key and the Up Key.

    Esc

    Esc

  • 8/8/2019 P&M Line list

    2/16

    Operating Instruction for Weighing Meter K3NV

    Page2

    MCI 70-N

    The following flowchart explains the setting procedure for the weighing meter.

    The display shows the data

    1Sec

    Setting Menu

    Scale Menu

    Setup Menu

    1Sec

    Input Range

    Set the parameter as shownblc 0 to 20mV input

    Frequency

    A

    Power On

    Run Mode display

    S U S E t

    S C A L E

    S E t U P

    I n - t

    b L C

    F r E

  • 8/8/2019 P&M Line list

    3/16

    Operating Instruction for Weighing Meter K3NV

    Page3

    MCI 70-N

    A

    Power line Frequency

    Input Range

    Setup Menu

    Option Menu

    1Sec

    Average Processing

    Movement Average 8 times

    Startup Compensation

    B

    5 0

    I n - t

    S E t U P

    Esc

    O p t

    A v G

    6 0 0 0 8

    S t C n E

  • 8/8/2019 P&M Line list

    4/16

    Operating Instruction for Weighing Meter K3NV

    Page4

    MCI 70-N

    B

    Power on delay 4 Sec

    Hysteresis

    Agg 5 ; Cem 2 ; Adm 0.05

    Comparitive Output Pattern

    Standard Output

    C

    4

    H Y S

    x

    C o U T

    n o n A L

    L S E t . H

    L S E t . L

  • 8/8/2019 P&M Line list

    5/16

    Operating Instruction for Weighing Meter K3NV

    Page5

    MCI 70-N

    C

    Option Menu

    Setting value Menu

    Scaling Menu

    1 Sec

    D

    A v G

    Esc

    o P t

    S u S E t

    S C A L E

    Starting of Calibration- Ensure that the weigheris empty.

    I n P . 2

    t E S t

  • 8/8/2019 P&M Line list

    6/16

    Operating Instruction for Weighing Meter K3NV

    Page6

    MCI 70-N

    Rese/ Teach

    Rese

    / Teach

    D

    Input Value 1

    1Sec

    The display shows theinput voltage in mV

    Display value 1

    Set value 0

    Decimal position

    E

    d S P . 2

    I n P . 1

    X . X X X X

    I n P . 1

    d s P . 1

    0

    d E C - P

  • 8/8/2019 P&M Line list

    7/16

    Operating Instruction for Weighing Meter K3NV

    Page7

    MCI 70-N

    E

    Decimal point positionAgg Nil ; Cem Nil ; Adm x.xxx

    Option Menu

    1Sec

    F

    X . X . X . X . X

    I n P . 2

    Esc

    S C A L E

    S E t U P

    o P t

    A v G

    S t C n E

    H Y S

  • 8/8/2019 P&M Line list

    8/16

    Operating Instruction for Weighing Meter K3NV

    Page8

    MCI 70-N

    Rese

    / Teach

    Rese

    / Teach

    F

    Linear Output Range - Low

    1 Sec

    The display shows the valuecorresponding to zero weighton the weigher.

    Option Menu

    G

    C o U t

    L S E t . H

    L S E t . L

    0

    L S E t . L

    Esc

    o P t

    t E S t

    S u S E t

  • 8/8/2019 P&M Line list

    9/16

    Operating Instruction for Weighing Meter K3NV

    Page9

    MCI 70-N

    Rese

    / Teach

    Rese

    / Teach

    G

    1 Sec

    Input Value 2

    1 Sec

    The display shows theinput voltage in mV

    Display value 2

    Enter the value corresponding toMaximum weigher value.

    Agg 1250 ; Cem 400 ; Adm 6.000

    H

    S C A L E

    Calibration for Max load- Ensure that the weigherloaded with maximumweight to be measured.Agg 1250Kg ; Cem 400KgAdm 6.000Kg

    I n P . 2

    X . X X X X

    I n P . 2

    d s P . 2

    X X X X

    I n P . 1

    Esc

  • 8/8/2019 P&M Line list

    10/16

    Operating Instruction for Weighing Meter K3NV

    Page10

    MCI 70-N

    H

    1Sec

    J

    S C A L E

    S E t U P

    o P t

    A v G

    S t C n E

    H Y S

    C o U t

  • 8/8/2019 P&M Line list

    11/16

    Operating Instruction for Weighing Meter K3NV

    Page11

    MCI 70-N

    Rese

    / Teach

    Rese

    / Teach

    J

    Linear Output Range - High

    1 Sec

    The display shows the valuecorresponding to Max. Weighton the weigher.

    Agg-1250; Cem- 400; Adm- 6.000

    Setting Value Menu

    1Sec

    Weigher Maximum value

    K

    L S E t . H

    x x x x

    L S E t . H

    Esc

    o P t

    t E S t

    S u S E t

    S u .H H

  • 8/8/2019 P&M Line list

    12/16

    Operating Instruction for Weighing Meter K3NV

    Page12

    MCI 70-N

    K

    Agg - 1250 ; Cem - 400 ; Adm 6.000

    Weigher Pre-Maximum value

    Agg - 1230 ; Cem - 395 ; Adm 5.950

    Weigher Empty value

    Agg - 5 ; Cem - 2 ; Adm - 0.005

    Agg : -5 ; Cem : -2 ; Adm : -0.005

    L

    X X X X

    S u . H

    X X X X

    S u . L

    X X X X

    S u . L L

    X X X X

  • 8/8/2019 P&M Line list

    13/16

    Operating Instruction for Weighing Meter K3NV

    Page13

    MCI 70-N

    L

    The Display shows weigher value

    +

    Protect Menu

    1 Sec

    All Key Protect

    Protect off

    Setting value change Prohibit

    M

    S u . H H

    Esc

    S u S E t

    Esc

    Run Mode

    P r o t

    Esc

    A L L

    u P o F F

    S u S E t

  • 8/8/2019 P&M Line list

    14/16

    Operating Instruction for Weighing Meter K3NV

    Page14

    MCI 70-N

    M

    Protect ON

    Zero Setting Prohibit

    Protect ON

    Maximum and Minimum value Prohibit

    Protect ON

    Security

    Setup Menu Prohibited

    N

    u P o N

    Z E r o

    u P o n

    n n . r S t

    u P o n

    S E C r

    1

  • 8/8/2019 P&M Line list

    15/16

    Operating Instruction for Weighing Meter K3NV

    Page15

    MCI 70-N

    N

    A L L

    Esc

    Run Mode End of Parameter Setting

  • 8/8/2019 P&M Line list

    16/16

    CP30 MCI70N

    Cable List