Planning aidKitchen appliances
2014/15
Note on content
Please noteThis planning aid is not to be used as installation instructions! The regulations and instructions binding for the appliance installationare to be obtained from the installation instructions packed with the appliances. The installation instructions can also be downloadedfrom the internet from www.vzug.com/b2b.
ModificationsText, diagrams and data correspond to the technical standard of the appliances at the time this planning aid went to press. The rightto make technical modifications for the purpose of the further development of the appliances is reserved.
Symbols used
Denotes important safety precautions.Failure to observe said precautions can result in injury or in damage to the appliance or fittings!
Indicates an instruction.
• Indicates a list.
Information and precautions that should be observed.
Supplementary documentsIn this planning aid, occasional reference is made to supplementary documents These documents can be obtained from the HeadOffice in Zug, Tel. + 41 58 767 67 78 or by e-mail from [email protected].
Key to country groups
Countrygroup
Country code(in accordance with ISO 3166)
Countrygroup
Country code(in accordance with ISO 3166)
A EU European UnionTR TurkeyIL IsraelLB Lebanon
D AU AustraliaNZ New Zealand
B GB Great BritainHK Hong KongSG Singapore
E RU RussiaUA Ukraine
C NO Norway F CN China
V-ZUG Ltd Planning aid J001.059-12Industriestrasse 66, P.O. Box 59, 6301 ZugTel. +41 58 767 67 67, Fax +41 58 767 61 61
Kitchen appliances03.09.14
[email protected], www.vzug.com
2
Contents
1 Overview of connections, ranges and dimensions 5 1.1 General operating conditions .............................................................................................................................................. 5 1.2 Validity ................................................................................................................................................................................ 5 1.3 Front dimensions of the appliances .................................................................................................................................... 92 Ovens 10 2.1 Electrical connection data ................................................................................................................................................... 10 2.2 Combair SLP (51A), SL (48A), SEP (45A), SE (42A) ......................................................................................................... 10 2.3 Combair XSL (49A), XSE (43A), XSLP (21026), XSEP (21020) ........................................................................................ 10 2.4 Hotair HSE (28A), Combair HSE (30A) .............................................................................................................................. 10 2.5 Combination possibilities .................................................................................................................................................... 113 Steam cookers 12 3.1 Electrical connection data ................................................................................................................................................... 12 3.2 Combair-Steam S (63A), N (61A) ....................................................................................................................................... 12 3.3 Combi-Steam SL (58A), Steam S (56A) ............................................................................................................................. 12 3.4 Combi-Steam XSL (59A) .................................................................................................................................................... 12 3.5 Combi-Steam XSLF (68A) .................................................................................................................................................. 13 3.6 Combination possibilities .................................................................................................................................................... 164 Coffee-Centers 17 4.1 Electrical connection data ................................................................................................................................................... 17 4.2 Supremo SL (75A) .............................................................................................................................................................. 17 4.3 Supremo XSL (76A) ............................................................................................................................................................ 17 4.4 Combination possibilities .................................................................................................................................................... 185 Warming and system drawers 19 5.1 General notes ..................................................................................................................................................................... 19 5.2 Electrical connection data ................................................................................................................................................... 19 5.3 Warming drawers with niche width 60 cm ........................................................................................................................... 20 5.4 System drawers with niche width 60 cm ............................................................................................................................. 236 Microwaves 24 6.1 Electrical connection data ................................................................................................................................................... 24 6.2 Miwell-Combi SL (947), XSL (939), Miwell SL (945) ........................................................................................................... 24 6.3 Miwell L (24002) .................................................................................................................................................................. 25 6.4 Combination possibilities .................................................................................................................................................... 267 Glass ceramic hobs – induction, wok, teppanyaki 28 7.1 General notes ..................................................................................................................................................................... 28 7.2 Electrical connection data ................................................................................................................................................... 29 7.3 Ventilation ........................................................................................................................................................................... 29 7.4 Operation ............................................................................................................................................................................ 29 7.5 Framed installation .............................................................................................................................................................. 30 7.6 Flush installation ................................................................................................................................................................. 35 7.7 Installation without protective plate ..................................................................................................................................... 41 7.8 Installation with protective plate .......................................................................................................................................... 43 7.9 Installing above oven / steam cooker .................................................................................................................................. 458 Toptronic glass ceramic hobs 46 8.1 General notes ..................................................................................................................................................................... 46 8.2 Electrical connection data ................................................................................................................................................... 46 8.3 Framed installation .............................................................................................................................................................. 47 8.4 Flush installation ................................................................................................................................................................. 509 Glass ceramic hobs for the replacement market 53 9.1 Appliances for the replacement market – induction ............................................................................................................ 53 9.2 Appliances for the replacement market – Toptronic ........................................................................................................... 5810 Examples for combined appliance installation 59
11 Gas hobs & lava grills 60 11.1 Gas hobs ............................................................................................................................................................................. 60 11.2 Lava grill .............................................................................................................................................................................. 63 11.3 2-zone induction hob ........................................................................................................................................................... 63 11.4 Installation examples for combined gas edition arrangement ............................................................................................. 6412 Range hoods 68 12.1 General notes ..................................................................................................................................................................... 68 12.2 Island hoods ........................................................................................................................................................................ 69
V-ZUG Ltd Planning aid J001.059-12Industriestrasse 66, P.O. Box 59, 6301 ZugTel. +41 58 767 67 67, Fax +41 58 767 61 61
Kitchen appliances03.09.14
[email protected], www.vzug.com
3
12.3 Wall hoods .......................................................................................................................................................................... 72 12.4 Built-in hoods ...................................................................................................................................................................... 77 12.5 Air recycling cassette (LRC) ............................................................................................................................................... 86 12.6 Air outlet cassette (LAC) ..................................................................................................................................................... 8613 Refrigerators 87 13.1 General notes ..................................................................................................................................................................... 87 13.2 Electrical connection data ................................................................................................................................................... 87 13.3 Room temperature .............................................................................................................................................................. 87 13.4 Niche ventilation .................................................................................................................................................................. 87 13.5 Refrigerators ....................................................................................................................................................................... 88 13.6 Winecoolers ........................................................................................................................................................................ 9014 Dishwashers 91 14.1 General notes ..................................................................................................................................................................... 91 14.2 Electrical connection data / plumbing in .............................................................................................................................. 91 14.3 Installation summary ........................................................................................................................................................... 93 14.4 Drilling plans for decor panel 60 cm .................................................................................................................................... 94 14.5 Adora SL, S, N with niche width 60 cm ............................................................................................................................... 9515 Dishwashers with heat pump 100 15.1 General notes ..................................................................................................................................................................... 100 15.2 Electrical connection data / plumbing in .............................................................................................................................. 100 15.3 Installation summary ........................................................................................................................................................... 102 15.4 Drilling plans for decor panel 60 cm .................................................................................................................................... 102 15.5 Adora SL WP with niche width 60 cm ................................................................................................................................. 10316 Accessories 106 16.1 Control set option (current sensor module with relay module) ............................................................................................ 106 16.2 Cookers / ovens / steam cookers / microwaves / coffee machines / warming & systems drawers .................................... 107 16.3 Glass ceramic hobs ............................................................................................................................................................ 109 16.4 Range hoods ....................................................................................................................................................................... 111 16.5 Refrigerators ....................................................................................................................................................................... 122 16.6 Dishwashers ....................................................................................................................................................................... 122
V-ZUG Ltd Planning aid J001.059-12Industriestrasse 66, P.O. Box 59, 6301 ZugTel. +41 58 767 67 67, Fax +41 58 767 61 61
Kitchen appliances03.09.14
[email protected], www.vzug.com
4
1 Overview of connections, ranges and dimensions
Electrical connections must be carried out by qualified experts.Plan a separate inlet for the electrical connection for each appliance.
1.1 General operating conditions
Detailed information on the electrical connection data can be found at the beginning of each section.
Value Nominal value Minimum MaximumVoltage 230 V
400 V207 V360 V
253 V440 V
Frequency 50 Hz sinusoidal 49 Hz sinusoidal 51 Hz sinusoidal
Short duration frequency variation in the mains: ± 5 %
Long duration frequency stability in the mains (for synchronous clocks): ± 10 ppm
The appliances are designed for use up to a max. altitude of 2000 m above sea level.
1.2 Validity
The product family (model number) corresponds to the first alphanumerics on the identification plate.
Ovens
Type Product familyCombair HSE 30ACombair SE 42ACombair SEP 45ACombair SL 48ACombair SLP 51ACombair XSE 43ACombair XSEP 21020Combair XSL 49ACombair XSLP 21026Hotair HSE 28A
Steam cookers
Type Product familyCombair-Steam N 61ACombair-Steam S 63ACombi-Steam SL 58ACombi-Steam XSL 59ACombi-Steam XSLF 68ASteam S 56A
Coffee-Centers
Type Product familySupremo SL 75ASupremo XSL 76A
1
V-ZUG Ltd Planning aid J001.059-12Industriestrasse 66, P.O. Box 59, 6301 ZugTel. +41 58 767 67 67, Fax +41 58 767 61 61
Kitchen appliances03.09.14
[email protected], www.vzug.com
5
Warming & system drawers
Type Product familySYS 60/144 620SYS 60/76 953WS 60/144 34003WS 60/162 34004WS 60/220 34005WS 60/283 34006
Microwave ovens
Type Product familyMiwell L 24002Miwell SL 945Miwell-Combi SL 947Miwell-Combi XSL 939
Glass ceramic induction
Type Product familyGK16TIWS.1F 31010GK16TIWSF 87AGK16TIYS.1F 31008GK16TIYSF 85AGK26TIMS, GK26TIMSF 84AGK26TIMS.1F 31011GK26TIMS.2F 31001GK26TIYS.1F 31009GK26TYSF 86AGK36TIPS, GK36TIPSC, GK36TIPSF 975GK36TIS, GK36TISC, GK36TISF 008GK36TIS.1F 31013GK46IABD, GK46IABDC, GK46IABDF 96AGK46IABD.1F 31022GK46ID, GK46IDC, GK46ID.1F, GK46IDF 31021GK46TIABS, GK46TIABSC, GK46TIABSF 028GK46TIABS.1F 31017GK46TIAKS, GK46TIAKSC, GK46TIAKSF 90AGK46TIMAS, GK46TIMASC, GK46TIMASF 31030GK46TIMPS, GK46TIMPSC, GK46TIMPSF 31029GK46TIMS, GK46TIMSC, GK46TIMSF 88AGK46TIMS.1F 31014GK46TIMXSC, GK46TIMXSF 31002GK46TIPS, GK46TIPSC, GK46TIPSF 973GK56TIMS, GK56TIMSC, GK56TIMSF 89AGK56TIMS.1F 31020
1
V-ZUG Ltd Planning aid J001.059-12Industriestrasse 66, P.O. Box 59, 6301 ZugTel. +41 58 767 67 67, Fax +41 58 767 61 61
Kitchen appliances03.09.14
[email protected], www.vzug.com
6
Glass ceramic Toptronic
Type Product familyGK25TE 005GK25TE.1F 31023GK35TEPS, GK35TEPSC, GK35TEPSF 31032GK45TEAS, GK45TEASC, GK45TEASF 977GK45TEAS.1F 31026GK45TEBS.1, GK45TEBS.1C, GK45TEBS.1F 032GK45TEBS.2F 31028GK45TEPS, GK45TEPSC, GK45TEPSF 976
Gas hobs & lava grills
Type Product familyGK1121TGCN 31035GK11TG 798GK11TKLG 98AGK11TTG 851GK21TG 797GK21TI 834GK21TTG 302GK41TG 717GK51TPG 701
Island hoods
Type Product familyDIPQ10 63007DI-B10 816DI-B12 93008DI-B14 821DI-M10 996DI-M12 997DIPQ13 63006DI-SE10 076DI-SE12 077
Wall hoods
Type Product familyDWPQ12 62006DW-B12 62008DW-B14 994DW-B9 993DW-F8 042DW-L9 990DW-M12 992DWPQ9 62007DW-SE12 068DW-SW9 059SW-M9 991
1
V-ZUG Ltd Planning aid J001.059-12Industriestrasse 66, P.O. Box 59, 6301 ZugTel. +41 58 767 67 67, Fax +41 58 767 61 61
Kitchen appliances03.09.14
[email protected], www.vzug.com
7
Built-in hoods
Type Product familyDFPQ12 61013DFPQ6 61015DFPQ9 61014DFPQSL6 61008DFPQSL9 61007DF-SG6 360DF-SG9 549DF-SLG6 384DF-SLG9 385DHL11 64002DHL8 64001
Refrigerators
Type Product familyCooltronic 60i 51029De Luxe 60i 51017Futura 60i 51020Komfort 60i 51048Magnum 60i eco 51031Noblesse 60i 51028Prestige 60i 51027Prestige P 60i eco 51052Royal 60i 51018Winecooler SL 629
Dishwashers
Type Product familyAdora N 41011, 41029, 41030-41033Adora S 41010, 41016, 41034-41037Adora SL 41005-41008, 41042, 41043Adora SL WP 41009, 41038
1
V-ZUG Ltd Planning aid J001.059-12Industriestrasse 66, P.O. Box 59, 6301 ZugTel. +41 58 767 67 67, Fax +41 58 767 61 61
Kitchen appliances03.09.14
[email protected], www.vzug.com
8
1.3 Front dimensions of the appliances
Manufacturing tolerance: ±1 mm
Applianceheight H
Fascia height H1 Door glass heightH2
Design handle G1 Handle length
598 124 457.5 43 415454 80 357.5 43 415378 50 311.5
Appliance without drawer
X
8.5
Y
8
35
20
H1
G1
H2
H
Detail XDetail X
4 m
m
Ove
rla
pp
ing
Ap
plia
nce
he
igh
t
Nic
he
he
igh
t
Detail Y
4
1
V-ZUG Ltd Planning aid J001.059-12Industriestrasse 66, P.O. Box 59, 6301 ZugTel. +41 58 767 67 67, Fax +41 58 767 61 61
Kitchen appliances03.09.14
[email protected], www.vzug.com
9
2 Ovens
2.1 Electrical connection data
Appliance Country group * Mains connection Fuse Rated load Mains cableCombair SLP, SL, SE, SEPCombair XSLP, XSEPCombair XSL, XSECombair HSE
A, C, E 230 V~ 50 Hz
16 A
SL(P), SE(P): 3400 WXSL(P), XSE(P): 3300 W
HSE: 3100 W
2.5 m, with plugB 2.5 m, without
plugD 220-240 V~ 50 HzF 2.5 m, with plug
Hotair HSE A, B, C, E 230 V~ 50 Hz 10 A 2400 W 2.1 m, with plugD, F 220-240 V~ 50 Hz
* Note on content [➙ see page 2]
2.2 Combair SLP (51A), SL (48A), SEP (45A), SE (42A)
59
8
569
440
596
59
4
600
≥ 550
560–568
X
Y
440569
600
600
≥ 550
598
596
560–568
2.3 Combair XSL (49A), XSE (43A), XSLP (21026), XSEP (21020)
454
596
569
600
≥ 550
450
560–568
X
346
Y
2.4 Hotair HSE (28A), Combair HSE (30A)
37
8
596
569
295
600
≥ 550
37
4
560–568
X
Y
Front dimensions of the appliances: Detail X/Y [➙ see page 9]
2
V-ZUG Ltd Planning aid J001.059-12Industriestrasse 66, P.O. Box 59, 6301 ZugTel. +41 58 767 67 67, Fax +41 58 767 61 61
Kitchen appliances03.09.14
[email protected], www.vzug.com
10
2.5 Combination possibilities
Hotair HSE, Combair HSE & oven
≥ 550
600
560–568
596 569
598
378
974
374
X
W
Y
≥ 550
600
560–568
974
594
596 569
378
598
X
W
Y
Hotair HSE, Combair HSE & steam cooker
≥ 550
600
560–568
596 569
378
378
754
374
X
W
Y
Combair XSL, XSE & oven
≥ 550
600
560–568
596 569
598
454
1050
450
X
W
Y
Combair XSL, XSE & Combi-Steam XSL
≥ 550
600
560–568
596 569
45
44
54
90
6
45
0
X
W
Y
W = Angle set K20198
If installing with a second appliance in the same niche, use the angle set 60 W (K20198).
Front dimensions of the appliances: Detail X/Y [➙ see page 9]
2
V-ZUG Ltd Planning aid J001.059-12Industriestrasse 66, P.O. Box 59, 6301 ZugTel. +41 58 767 67 67, Fax +41 58 767 61 61
Kitchen appliances03.09.14
[email protected], www.vzug.com
11
3 Steam cookersOnly use if water hardness > 3 French degrees (> 1.7 German degrees) possible.
3.1 Electrical connection data
Appliance Country group * Mains connection Fuse Rated load Mains cable Combair-Steam S, NCombi-Steam XSL, XSLF, SL
A, C, E 230 V~ 50 Hz
16 AS, N, XSL(F): 3700 W
SL: 3500 W
2.1 m, with plugB 2.1 m, without
plugD 220-240 V~ 50 HzF
2.1 m, with plugSteam S
A, B, C, E 230 V~ 50 Hz 10 A 2200 WD, F 220-240 V~ 50 Hz
* Note on content [➙ see page 2]
3.2 Combair-Steam S (63A), N (61A)
59
8
569
440
596
59
4
600
≥ 550
560–568
X
Y
440569
600
600
≥ 550
598
596
560–568
3.3 Combi-Steam SL (58A), Steam S (56A)
37
8
596
569
295
600
≥ 550
37
4
560–568
X
Y
3.4 Combi-Steam XSL (59A)
454
596
569
600
≥ 550
450
560–568
X
346
Y
Front dimensions of the appliances: Detail X/Y [➙ see page 9]
3
V-ZUG Ltd Planning aid J001.059-12Industriestrasse 66, P.O. Box 59, 6301 ZugTel. +41 58 767 67 67, Fax +41 58 767 61 61
Kitchen appliances03.09.14
[email protected], www.vzug.com
12
3.5 Combi-Steam XSLF (68A)
454
596
569
600
575
450
560–568
X
346
≥ 40Y
Front dimensions of the appliances: Detail X/Y [➙ see page 9]
Below second appliance
Depth > 555 mmAbove second appliance
Depth > 575 mmAbove warming drawer
Depth > 555 mm
W
X456
Y
50
≥ 40
W
450
X
Y
50
≥ 40
W
450
X
Y50
≥ 40
X = Height of second applianceY = Niche heightW = Angle set K20198
For an installation depth under 575 mm, it is recommended that the appliance be installed below other appliances for spacereasons.If installing with a second appliance in the same niche, use the angle set 60 W (K20198).
3
V-ZUG Ltd Planning aid J001.059-12Industriestrasse 66, P.O. Box 59, 6301 ZugTel. +41 58 767 67 67, Fax +41 58 767 61 61
Kitchen appliances03.09.14
[email protected], www.vzug.com
13
Installation
≥ 40
≥ 40
≥ 40
3
V-ZUG Ltd Planning aid J001.059-12Industriestrasse 66, P.O. Box 59, 6301 ZugTel. +41 58 767 67 67, Fax +41 58 767 61 61
Kitchen appliances03.09.14
[email protected], www.vzug.com
14
Plumbing in
1
4
2 73 56
≥ 5
0
70
0
1 Hose clamp2 Reinforced inlet hose 2 m, G ¾"3 Drain hose 3 m Inner diameter of connection 22 mm On-site installations4 Siphon5 Plinth panel6 Hose fed through plinth7 Cold water connection with stop-cock
OutletLength of drain hose 3 m
The hose loop must be mounted at a height of 700 mm (see illustration above).The drain hose may be neither lengthened nor shortened.The distance from the bottom of the appliance to the drain trap must be at least 50 mm.The drain hose must be laid flat without any kinks.
Cold water connection inletOperating pressure: 0.1-1.0 MPa (1-10 bar)
Only use if water hardness > 3 French degrees (> 1.7 German degrees) possible.
Length of reinforced hose: 2 m
Local water authority regulations must be observed.Existing hoses that are defective must be replaced.The reinforced hose may not be lengthened.The stop-cock must be accessible at all times.
3
V-ZUG Ltd Planning aid J001.059-12Industriestrasse 66, P.O. Box 59, 6301 ZugTel. +41 58 767 67 67, Fax +41 58 767 61 61
Kitchen appliances03.09.14
[email protected], www.vzug.com
15
3.6 Combination possibilities
Combi-Steam SL, Steam S & oven
≥ 550
600
560–568
596 569
598
378
974
374
X
W
Y
≥ 550
600
560–568
974
594
596 569378
598
X
W
Y
Combi-Steam SL, Steam S & Hotair HSE, Combair HSE
≥ 550
600
560–568
596 569
378
378
754
374
X
W
Y
Combi-Steam XSL, Combair XSL, XSE & oven
≥ 550
600
560–568
596 569
598
454
1050
450
X
W
Y
Combi-Steam XSL & Combair XSL, XSE
≥ 550
600
560–568
596 569
45
44
54
90
6
45
0
X
W
Y
If installing with a second appliance in the same niche, use the angle set 60 W (K20198).
Front dimensions of the appliances: Detail X/Y [➙ see page 9]
3
V-ZUG Ltd Planning aid J001.059-12Industriestrasse 66, P.O. Box 59, 6301 ZugTel. +41 58 767 67 67, Fax +41 58 767 61 61
Kitchen appliances03.09.14
[email protected], www.vzug.com
16
4 Coffee-CentersDepth of wall unit must be min. 480 mm.
4.1 Electrical connection data
Mains connection Fuse Mains cable230 V~ 50Hz 10 A 1.8 m, with plug
4.2 Supremo SL (75A)
600
550
374
560–568
X
596 412
378
480
Y
4.3 Supremo XSL (76A)
600
450
550
560-568
596 412
454
XX
480
Y
Front dimensions of the appliances: Detail X/Y [➙ see page 9]
4
V-ZUG Ltd Planning aid J001.059-12Industriestrasse 66, P.O. Box 59, 6301 ZugTel. +41 58 767 67 67, Fax +41 58 767 61 61
Kitchen appliances03.09.14
[email protected], www.vzug.com
17
4.4 Combination possibilities
Supremo SL & oven Supremo SL & Hotair HSE, Combair HSE or steam cooker
596 569
≥ 550
600
560–568
598
974
374412
378
480
596 569
≥ 550
600
560–568
378
754
374 412
378
480
Supremo SL & Miwell SL Supremo XSL & compact oven or steam cooker
596 513
378
≥ 550
600
560–568
754
374412
378
480
596 569
≥ 550
600
560–568
906
450
X
454
412
454
480
Y
Front dimensions of the appliances: Detail X/Y [➙ see page 9]
4
V-ZUG Ltd Planning aid J001.059-12Industriestrasse 66, P.O. Box 59, 6301 ZugTel. +41 58 767 67 67, Fax +41 58 767 61 61
Kitchen appliances03.09.14
[email protected], www.vzug.com
18
5 Warming and system drawers
5.1 General notes
Efficient repairs can only be guaranteed if it is possible to uninstall the whole appliance at any time without causing anydamage.
5.2 Electrical connection data
Plan a separate inlet for the electrical connection for each appliance, except for the «Combi connection». If connectedtogether, take the rated load into account.
General information on the electrical connections and an overview of the positions can be found in the Overview of connec-tions, ranges and dimensions [➙ see page 5] section.
Mains connection Fuse Mains cable Rated load230 V~ 50 Hz 10 A 1.7 m, with plug 810 W
5
V-ZUG Ltd Planning aid J001.059-12Industriestrasse 66, P.O. Box 59, 6301 ZugTel. +41 58 767 67 67, Fax +41 58 767 61 61
Kitchen appliances03.09.14
[email protected], www.vzug.com
19
5.3 Warming drawers with niche width 60 cm
The angle mountings are not included in the scope of delivery. Order angle set K20198 at the same time.
WS 60/144 (34003)Built-in solo
144
560–568
596 547
142
600
≥ 550
Installing with compact oven or steam cooker Installing with oven & compact oven or steam cooker
454
142
596 547
567
600
560–568
594 4
50
X
≥ 550
Y
≥ 550
600
560–568
598
142
596 547
569
454
1194
450
X
600
Y
Front dimensions of the appliances: Detail X/Y [➙ see page 9]
5
V-ZUG Ltd Planning aid J001.059-12Industriestrasse 66, P.O. Box 59, 6301 ZugTel. +41 58 767 67 67, Fax +41 58 767 61 61
Kitchen appliances03.09.14
[email protected], www.vzug.com
20
WS 60/162 (34004)Built-in solo Installing with an oven
162
560–568
596 547
160
600
≥ 550
598
160
596 547
600
560–568
756*
594**
X
567
≥ 550
Y
Installation height:* Niche height 762 mm** Height 600 mm
Installing with oven & mini oven or steam cooker
596 547
598
160
378
569
min. 550
600
560–568
1136
374
X
600
Y
Front dimensions of the appliances: Detail X/Y [➙ see page 9]
5
V-ZUG Ltd Planning aid J001.059-12Industriestrasse 66, P.O. Box 59, 6301 ZugTel. +41 58 767 67 67, Fax +41 58 767 61 61
Kitchen appliances03.09.14
[email protected], www.vzug.com
21
WS 60/220 (34005)Built-in solo Installing with mini oven or steam cooker
220
560–568
596 547
218
600
≥ 550
378
218
596 547
600
560–568
594
374
X
567
≥ 550
Y
For niche height 635 mm -> Adapter frame, see section Accesso-ries [➙ see page 106]
WS 60/283 (34006)Built-in solo Installing with an oven
283
560–568
596 547
281
600
≥ 550
598
281
596 547
600
560–568
877
594
X
567
≥ 550
Y
Front dimensions of the appliances: Detail X/Y [➙ see page 9]
5
V-ZUG Ltd Planning aid J001.059-12Industriestrasse 66, P.O. Box 59, 6301 ZugTel. +41 58 767 67 67, Fax +41 58 767 61 61
Kitchen appliances03.09.14
[email protected], www.vzug.com
22
5.4 System drawers with niche width 60 cm
SYS 60/144 (620)Installing with Supremo XSL
≥ 550
600
560–568
59
4
45
0
X
14
2
596 547
412
454
480
Y
SYS 60/76 (953)Installing with Supremo SL
600
≥ 550
560–568
450
374
X
74
596 560
412
378
Y
The telescopic runner for the assembly and operation is included in the scope of delivery.
Front dimensions of the appliances: Detail X/Y [➙ see page 9]
5
V-ZUG Ltd Planning aid J001.059-12Industriestrasse 66, P.O. Box 59, 6301 ZugTel. +41 58 767 67 67, Fax +41 58 767 61 61
Kitchen appliances03.09.14
[email protected], www.vzug.com
23
6 Microwaves
Minimum installation height (child safety): Keep 850 mm distance from the floor to the bottom edge of the microwave!
The mounting angles are not included in the scope of delivery. Order angle set K20198 at the same time.
6.1 Electrical connection data
Type Mains connection Fuse Mains cableMiwell-Combi XSL 230 V~ 50 Hz 16 A 1.2 m, without plugMiwell-Combi SL,Miwell SL / L
230 V~ 50 Hz 10 A 1.2 m, with plug
6.2 Miwell-Combi SL (947), XSL (939), Miwell SL (945)
Miwell-Combi SL, Miwell SL Miwell-Combi XSL
378
596
T300
600
≥ 550
374 ¹
560-568
X
Y 454
596
567
600
450
560–568
X
350
Y
Appliance T Miwell-Combi SL 516 mm Miwell SL 470 mm
Front dimensions of the appliances: Detail X/Y [➙ see page 9]
6
V-ZUG Ltd Planning aid J001.059-12Industriestrasse 66, P.O. Box 59, 6301 ZugTel. +41 58 767 67 67, Fax +41 58 767 61 61
Kitchen appliances03.09.14
[email protected], www.vzug.com
24
6.3 Miwell L (24002)
Door hinged left!
2050
==
600
381
762
596
378
320
≥ 330
560
6
V-ZUG Ltd Planning aid J001.059-12Industriestrasse 66, P.O. Box 59, 6301 ZugTel. +41 58 767 67 67, Fax +41 58 767 61 61
Kitchen appliances03.09.14
[email protected], www.vzug.com
25
6.4 Combination possibilities
The mounting angles are not included in the scope of delivery. Order angle set K20198 at the same time.
Miwell-Combi SL & oven Miwell-Combi SL & mini oven or steam cooker
596 569
516
≥ 550
600
560–568
598
378
974
374
X
Y
596 569
516
≥ 550
600
560–568
378
378
754
374
X
Y
Miwell-Combi XSL & oven Miwell-Combi XSL & Combair XSL, XSE or Combi-
Steam XSL
600
560–568
596 569
59
8454
105
0
450
X
Y600
560–568
596 569
454
454
906
450
X
Y
Front dimensions of the appliances: Detail X/Y [➙ see page 9]
6
V-ZUG Ltd Planning aid J001.059-12Industriestrasse 66, P.O. Box 59, 6301 ZugTel. +41 58 767 67 67, Fax +41 58 767 61 61
Kitchen appliances03.09.14
[email protected], www.vzug.com
26
Miwell S & oven
M
596 569
≥ 550
560-568
598
378
981
381
350
600
M assembly kit is included in the scope of delivery.
Door hinged left
6
V-ZUG Ltd Planning aid J001.059-12Industriestrasse 66, P.O. Box 59, 6301 ZugTel. +41 58 767 67 67, Fax +41 58 767 61 61
Kitchen appliances03.09.14
[email protected], www.vzug.com
27
7 Glass ceramic hobs – induction, wok, teppanyaki
7.1 General notes
It is imperative for induction hobs to have adequate ventilation (see sections Installation without protective plate [➙ seepage 41] and Installation with protective plate [➙ see page 43]).This is guaranteed with a worktop depth of 20 mm to 40 mm.If a drawer is installed directly underneath, a protective plate is recommended in the vicinity of the mains cable and to protectthe ventilation openings. The protective plate set can be used (see Accessories [➙ see page 106]).With a front-facing air gap of 3 mm, a ventilation protective plate with seal is essential (Installation with protective plate [➙see page 43]).
Efficient repairs can only be guaranteed if it is possible to uninstall the whole appliance at any time without causing anydamage.
The layout of the hobs to be installed may differ from the hobs illustrated here!
Dear Customer
This planning aid contains the dimensions of all our current glass ceramic hobsSince April 2013, most of the flush induction hobs require larger cut-out dimensions and other corner radii. If you own an appliancewhich was manufactured before April 2013, please make sure that you do select the correct cut-out dimensions.The cut-out dimensions for flush induction hobs can be found in section Glass ceramic hobs for the replacement market [➙ seepage 53].
Our product range naturally still includes hobs which have the previous cut-out dimensions.
Thank you for reading this information.
Your V-ZUG Ltd
7
V-ZUG Ltd Planning aid J001.059-12Industriestrasse 66, P.O. Box 59, 6301 ZugTel. +41 58 767 67 67, Fax +41 58 767 61 61
Kitchen appliances03.09.14
[email protected], www.vzug.com
28
7.2 Electrical connection data
Type Country Mains connection Fuse Mains cableGK16TIWS.1F,GK16TIYS.1F,GK26TIMS …
AU, CN, EU, GB, HK, IL,LB, NO, RU, SG, UA, TR
220-240 V~50/60 Hz16 A
1.7 m, without plugGK26TIYS.1F, GK36TI…,GK46TI…, GK46ID…,GK46IABD
EU, IL, LB, RU, UA, TR 380-415 V~ 2N 50/60 HzAU, CN, GB, HK, NO, SG 220-240 V~50/60 Hz 32 A
GK56TIMS … EU, IL, LB, NO, RU, UA,TR
380-415 V~ 3N 50/60 Hz 16 A
AU, CN, GB, HK, SG 220-240 V~50/60 Hz 48 A
7.3 Ventilation
In order to guarantee good ventilation, a space of≥ 17.5 mm height is necessary beneath the appli-ance.1. The back wall of the base unit must be open
in the area of the worktop cut-out to guar-antee continuous air circulation over theventilation slits.
2. Alternatively, air circulation inside the cabinetcan be provided for by a concealed fresh airintake.In order that enough cold air can be drawn in,there must be a continuous circulation offresh air that extends outside the cabinet.
≥ 15
21
7.4 Operation
Type Operating typeGK46ID…, GK46IABD… Dial controls according to J553.053
7
V-ZUG Ltd Planning aid J001.059-12Industriestrasse 66, P.O. Box 59, 6301 ZugTel. +41 58 767 67 67, Fax +41 58 767 61 61
Kitchen appliances03.09.14
[email protected], www.vzug.com
29
7.5 Framed installation
Aim for corner radii of cut-out: ≤ 10 mm.Corner radii of appliance: 8 mm
GK26TIMS (84A) GK36TIS (008), GK36TISC (008), GK46TIMS (88A), GK46TIMSC (88A)
514
289
H
Y
Y
≥ 5
0
≥ 5
0
490
±1
600
265 ±1
A
275
Ri
Ra
490
±1
560 ±1
600
≥ 5
0
≥ 5
0
A
600
584
514
Y
Y
Ri
H
Ra
≥ 1
7.5
*
B
Y – Y
Drawer/Cabinet
* The clearance space must be provided!
Type ADepends on producer
B H Corner radiusRa/Ri
GK26TIMS ≥ 30 mm
≥ 65.2 mm 47.7 mm 10/8 mmGK36TIS, GK46TIMS
GK36TISC, GK46TIMSC ≥ 67.2 mm 49.7 mm
A Worktop depth (in combination with directly built-under oven)H Measurement from the top side of the worktop to the underside of the hob (ventilation opening)Ri Corner radii of applianceRa Outer corner radii of cut-out
7
V-ZUG Ltd Planning aid J001.059-12Industriestrasse 66, P.O. Box 59, 6301 ZugTel. +41 58 767 67 67, Fax +41 58 767 61 61
Kitchen appliances03.09.14
[email protected], www.vzug.com
30
GK46IABD (96A), GK46IABDC (96A), GK46TIMAS (31030), GK46TIMASC (31030),
GK46TIABS (028), GK46TIABSC (028), GK46TIAKS (90A), GK46TIAKSC (90A)
GK36TIPS (975), GK36TIPSC (975)
514
H
774
Y
Y
490
±1
≥ 5
0
≥ 5
0
600
750 ±1
600
A
1
Ri
Ra
H
774
444
Y
Y
420
±1
≥ 5
0
≥ 5
0
750 ±1
600
A
Ri
Ra
≥ 1
7.5
*
B
Y – Y
Drawer/Cabinet
* The clearance space must be provided!
Type ADepends on producer
B H Corner radiusRa/Ri
GK46IABD, GK46TIMAS,GK46TIABS, GK46TIAKS
≥ 30 mm
≥ 64.0 mm 46.5 mm
10/8 mmGK36TIPS ≥ 65.2 mm 47.7 mmGK46IABDC, GK46TIMASC,GK46TIABSC, GK46TIAKSC,GK36TIPSC
≥ 66.0 mm 48.5 mm
A Worktop depth (in combination with directly built-under oven)H Measurement from the top side of the worktop to the underside of the hob (ventilation opening)Ri Corner radii of applianceRa Outer corner radii of cut-out1 For symmetrical installation, it is not necessary to cut out the side walls
7
V-ZUG Ltd Planning aid J001.059-12Industriestrasse 66, P.O. Box 59, 6301 ZugTel. +41 58 767 67 67, Fax +41 58 767 61 61
Kitchen appliances03.09.14
[email protected], www.vzug.com
31
GK46ID (95A), GK46IDC (95A) GK46TIMXSC (31002)
490
±1
560 ±1
600
≥ 5
0
≥ 5
0
A
600
584
514
Y
Y
Ri
H
Ra
514
H
704
Y
Y
Ri
490
±1
≥ 5
0
≥ 5
0
A
600
680 ±1
600
=
=
=
=
1
Ra
92
600 42
±0.5
X
±0.5
≥ 103
≥ 38
5*
Fo
r ve
ntila
tio
n
x
≥ 1
7.5
*
B
Y – Y
Drawer/Cabinet
* The clearance space must be provided!
X = Ventilation slit 5 mm across the entire width of the unit, at least 25 cm².
Type ADepends on producer
B H Corner radiusRa/Ri
GK46ID ≥ 30 mm
≥ 65.2 mm 47.7 mm 10/8 mmGK46IDC ≥ 67.2 mm 49.7 mm
GK46TIMXSC ≥ 66.0 mm 48.5 mm
A Worktop depth (in combination with directly built-under oven)H Measurement from the top side of the worktop to the underside of the hob (ventilation opening)Ri Corner radii of applianceRa Outer corner radii of cut-out1 For symmetrical installation, it is not necessary to cut out the side walls
7
V-ZUG Ltd Planning aid J001.059-12Industriestrasse 66, P.O. Box 59, 6301 ZugTel. +41 58 767 67 67, Fax +41 58 767 61 61
Kitchen appliances03.09.14
[email protected], www.vzug.com
32
GK46TIMPS (31029), GK46TIMPSC (31029), GK46TIPS (973), GK46TIPSC (973)
410
910
H
Y
Y
X
X
1
123
A
886 ±1386
±1
900
≥ 7
0
≥ 7
0
200
50
825
=
=
386
Ri
Ra
X – X
≥
15
≥ 1
7.5
*
B
Drawer/
cabinet/
side panel
≥ 1
7.5
*
B
Y – Y
Drawer/Cabinet
* The clearance space must be provided!For niche width 900/825 mm, cut-outs in side walls left/right are necessary for the ventilation of the appliance. Keep blow-out opening free.
Type ADepends on producer
B H Corner radiusRa/Ri
GK46TIMPS ≥ 30 mm
≥ 64.5 mm 47.0 mm 10/8 mmGK46TIPS ≥ 62.8 mm 45.3 mm
GK46TIMPSC ≥ 67.2 mm 49.7 mmGK46TIPSC ≥ 65.5 mm 48.0 mm
A Worktop depth (in combination with directly built-under oven)H Measurement from the top side of the worktop to the underside of the hob (ventilation opening)Ri Corner radii of applianceRa Outer corner radii of cut-out1 Front and rear struts are reinforced on the underside. The strut width is determined by the producer of the stone
worktop. The minimum strut width can vary according to the property of the stone.2 For symmetrical installation, it is not necessary to cut out the side walls.
7
V-ZUG Ltd Planning aid J001.059-12Industriestrasse 66, P.O. Box 59, 6301 ZugTel. +41 58 767 67 67, Fax +41 58 767 61 61
Kitchen appliances03.09.14
[email protected], www.vzug.com
33
GK56TIMS (89A), GK56TIMSC (89A)
514
910
H
900
A
600
886 ±1
≥ 5
0
490 ±
1
≥ 5
0
Y
Y
B
825
=
=
≥ 4
90
2
1
Ri
Ra
≥ 1
7.5
*
B
Y – Y
Drawer/Cabinet
* The clearance space must be provided!For niche width 900/825 mm, cut-outs in side walls left/right are necessary for the ventilation of the appliance. Keep blow-out opening free.
Type ADepends on producer
B H Corner radiusRa/Ri
GK56TIMS ≥ 30 mm ≥ 66.8 mm 49.3 mm 10/8 mmGK56TIMSC ≥ 68.8 mm 51.3 mm
A Worktop depth (in combination with directly built-under oven)H Measurement from the top side of the worktop to the underside of the hob (ventilation opening)Ri Corner radii of applianceRa Outer corner radii of cut-out1 For symmetrical installation, it is not necessary to cut out the side walls.2 Front and rear struts are reinforced on the underside. The strut width is determined by the producer of the stone
worktop. The minimum strut width can vary according to the property of the stone.
7
V-ZUG Ltd Planning aid J001.059-12Industriestrasse 66, P.O. Box 59, 6301 ZugTel. +41 58 767 67 67, Fax +41 58 767 61 61
Kitchen appliances03.09.14
[email protected], www.vzug.com
34
7.6 Flush installation
Hob must be removable from below!
GK16TIWS.1F (31010) GK26TIMS.1F (31011)
H
384
501
390 ±1
≥ 4
1.5
≥ 4
1.5 600
507
±1
A
Z
600 ≥ 400
≥ 1
46
*
Ri
W
A
600
275
≥ 4
1.5
507 ±
1
≥ 4
1.5
Z
287 ±1
H
X
Ri 281
501
Y
Y
X
C D
Ra
R0–5
8.5 0
-1
8.5 0
-0.5
8.5
0/+
18.5
0/+
1
Steel angle bonded or screw mounted
Detail Z
H≥
17
.5 *
Y – Y
B
Drawer/Cabinet
Side wall
* The clearance space must be provided!
Type ADepends on producer
B C/D H Corner radiusRa/Ri
GK16TIWS.1F ≥ 30 mm ≥ 205 mm 373/490 mm 128.5 mm 5/1.5 mmGK26TIMS.1F ≥ 55 mm 270/490 mm 51.7 mm
A Worktop depth (in combination with directly built-under oven)B Necessary clearance space for service requirementsH Measurement from the top side of the worktop to the underside of the hob trayW The intermediate base must be removable from below.Ri Corner radii of appliance Ra Outer corner radii of cut-out
7
V-ZUG Ltd Planning aid J001.059-12Industriestrasse 66, P.O. Box 59, 6301 ZugTel. +41 58 767 67 67, Fax +41 58 767 61 61
Kitchen appliances03.09.14
[email protected], www.vzug.com
35
GK16TIYS.1F (31008) GK26TIYS.1F (31009)
H
384
501
Y
Y
600 ≥ 400
≥ 4
1.5
600
≥ 4
1.5
Z
≥ 7
3.6
*
≥ 300
507 ±
1
390 ±1
A
Ri
for
ventila
tion
On both sides, for
technical reasons
501
571
H
Y
Y
600 A
Z
600
≥ 300
577 ±1
507±
1
Ri
≥
73
.6 *
for
ve
ntila
tio
n
On both sides,
for technical
reasons
≥ 4
1.5
≥ 4
1.5
H≥
17
.5 *
Y – Y
B
Drawer/Cabinet
Side wall
C D
Ra
R0–5
8.5 0
-1
8.5 0
-0.5
8.5
0/+
18.5
0/+
1
Steel angle bonded or screw mounted
Detail Z
* The clearance space must be provided!
Type ADepends on producer
B C/D H Corner radiusRa/Ri
GK16TIYS.1F ≥ 30 mm ≥ 55 mm 373/490 mm 57.1 mm 5/1.5 mmGK26TIYS.1F 560/490 mm
A Worktop depth (in combination with directly built-under oven)B Necessary clearance space for service requirementsH Measurement from the top side of the worktop to the underside of the hob trayRi Corner radii of applianceRa Outer corner radii of cut-out
7
V-ZUG Ltd Planning aid J001.059-12Industriestrasse 66, P.O. Box 59, 6301 ZugTel. +41 58 767 67 67, Fax +41 58 767 61 61
Kitchen appliances03.09.14
[email protected], www.vzug.com
36
GK26TIMS.2F (31001) GK36TIS.1F (31013), GK46ID.1F (31021),GK46TIMS.1F (31014)
600
501
384Ri
H
390 ±1
≥ 4
1.5
Z
600
507
±1
≥ 4
1.5
=
=
A
507
±1
577 ±1
600
≥ 4
1.5
≥ 4
1.5
A
600
571
501
Y
Y
Ri
Z
H
H≥
17
.5 *
Y – Y
B
Drawer/Cabinet
Side wall
C D
Ra
R0–5
8.5 0
-1
8.5 0
-0.5
8.5
0/+
18.5
0/+
1
Steel angle bonded or screw mounted
Detail Z
* The clearance space must be provided!
Type ADepends on producer
B C/D H Corner radiusRa/Ri
GK 26TIMS.2F ≥ 30 mm ≥ 55 mm 373/490 mm 51.7 mm 5/1.5 mmGK36TIS.1F, GK46ID.1F,GK46TIMS.1F
560/490 mm
A Worktop depth (in combination with directly built-under oven)B Necessary clearance space for service requirementsH Measurement from the top side of the worktop to the underside of the hob trayRi Corner radii of applianceRa Outer corner radii of cut-out
7
V-ZUG Ltd Planning aid J001.059-12Industriestrasse 66, P.O. Box 59, 6301 ZugTel. +41 58 767 67 67, Fax +41 58 767 61 61
Kitchen appliances03.09.14
[email protected], www.vzug.com
37
GK46TIAKSF (90A), GK46TIMASF (31030),GK46TIABS.1F (31017), GK46IABD.1F (31022)
GK46TIMXSF (31002)
501
761Y
Y
507
±1
≥ 4
1.5
≥ 4
1.5
600
767 ±1
600
A
Z
Ri
H
501
691
Y
Y
A
507
±1
≥ 4
1.5
≥ 4
1.5
600
Z
697 ±1
600
Ri
H
H≥
17
.5 *
Y – Y
B
Drawer/Cabinet
Side wall
C D
Ra
R0–5
8.5 0
-1
8.5 0
-0.5
8.5
0/+
18.5
0/+
1
Steel angle bonded or screw mounted
Detail Z
* The clearance space must be provided!
Type ADepends on producer
B* C/D H Corner radiusRa/Ri
GK46TIMASF, GK46TIAKSF,GK46TIABS.1F, GK46IABD.1F
≥ 30 mm
≥ 55 mm
750/490 mm 50.5 mm 5/1.5 mm
GK46TIMXSF 680/490 mm 51.7 mm
A Worktop depth (in combination with directly built-under oven)B Necessary clearance space for service requirementsH Measurement from the top side of the worktop to the underside of the hob trayRi Corner radii of applianceRa Outer corner radii of cut-out
7
V-ZUG Ltd Planning aid J001.059-12Industriestrasse 66, P.O. Box 59, 6301 ZugTel. +41 58 767 67 67, Fax +41 58 767 61 61
Kitchen appliances03.09.14
[email protected], www.vzug.com
38
GK36TIPSF (975) GK46TIPSF (973), GK46TIMPSF (31029)
H
744
414
Y
YX
X
420
±1
≥ 5
5
≥ 5
5
750 ±1
600
A
Z
Ri
380
880
H
W
W
2
123
A
886 ±1
≥ 7
0
386
±1
200
Z
≥ 7
0
900
82
825
=
=
≥ 4
56
1
Ri
C D
Ra
R0–5
8.5 0
-1
8.5 0
-0.5
8.5
0/+
18.5
0/+
1
Steel angle bonded or screw mounted
Detail Z
H≥
17
.5 *
Y – Y
B
Drawer/Cabinet
Side wall
B
≥ 1
7.5
*
600
H
X – X W - W
≥ 1
5
≥ 1
7.5
*
2
Drawer/Cabinet
* The clearance space must be provided!
Type ADepends on producer
B* C/D H Corner radiusRa/Ri
GK36TIPSF ≥ 30 mm
≥ 55 mm
733/403 mm 51.0 mm
5/1.5 mmGK46TIPSF,
GK46TIMPSF869/369 mm
A Worktop depth (in combination with directly built-under oven)B Necessary clearance space for service requirementsH Measurement from the top side of the worktop to the underside of the hob trayRi Corner radii of appliance Ra Outer corner radii of cut-out1 Front and rear struts are reinforced on the underside. The strut width is determined by the producer of the stone worktop. The
minimum strut width can vary according to the property of the stone.2 For niche width 900/825 mm, cut-outs in side walls left/right are necessary for the ventilation of the appliance. Keep blow-out
opening free.
7
V-ZUG Ltd Planning aid J001.059-12Industriestrasse 66, P.O. Box 59, 6301 ZugTel. +41 58 767 67 67, Fax +41 58 767 61 61
Kitchen appliances03.09.14
[email protected], www.vzug.com
39
GK56TIMS.1F (31020)
501
897
H
900
A
600
903 ±1
≥ 5
0
507 ±
1
≥ 5
0
Y
Y
B
825
=
=
≥ 4
90
2
1
Ri
C D
Ra
R0–5
8.5 0
-1
8.5 0
-0.5
8.5
0/+
18.5
0/+
1
Steel angle bonded or screw mounted
Detail Z
H≥
17
.5 *
Y – Y
B
Drawer/Cabinet
Side wall
* The clearance space must be provided!
Type ADepends on producer
B C/D H Corner radiusRa/Ri
GK56TIMS.1F ≥ 30 mm ≥ 55 mm 886/490 mm 53.3 mm 5/1.5 mm
A Worktop depth (in combination with directly built-under oven)B Necessary clearance space for service requirementsH Measurement from the top side of the worktop to the underside of the hob trayRi Corner radii of appliance Ra Outer corner radii of cut-out1 For symmetrical installation, it is not necessary to cut out the side walls.2 Front and rear struts are reinforced on the underside. The strut width is determined by the producer of the stone worktop. The
minimum strut width can vary according to the property of the stone.
7
V-ZUG Ltd Planning aid J001.059-12Industriestrasse 66, P.O. Box 59, 6301 ZugTel. +41 58 767 67 67, Fax +41 58 767 61 61
Kitchen appliances03.09.14
[email protected], www.vzug.com
40
7.7 Installation without protective plate
Requirements for optimal ventilation:
- a front-facing air gap of ≥ 5 mm
- a space of ≥ 17.5 mm in height beneath the appliance
- a worktop depth of ≥ 20 mm to ≤ 40 mm
- a supply of fresh air (≥ 15 mm air gap) is essential for the trouble-free operation of the hob.
GK26TI …, GK36TI …, GK46TI …
30
≥ 5
≥ 1
7.5
17.5
(50)
A ≥
67.5
≥ 15 600
Air gap over entire cabinet width ≥ 25 cm²
Necessary space below work surface for ventilation
Drawer Fan
GK46TIABS …, GK46TIAKS …
*C
≥ 5
5
600
GK56TIMS …
900
825 *C
≥ 5
5
bei N
ische 8
25
Ventilatoren
* Required for flush appliancesA Necessary space below the worktop for the ventilation of the applianceC Cut-out in side walls for disassembly from below, only for flush version
7
V-ZUG Ltd Planning aid J001.059-12Industriestrasse 66, P.O. Box 59, 6301 ZugTel. +41 58 767 67 67, Fax +41 58 767 61 61
Kitchen appliances03.09.14
[email protected], www.vzug.com
41
GK46ID …, GK46IABD …
≥ 5
30
50
≥ 3
8≥
103
*C
≥ 5
5
≥ 15
600
92±0.5
42
±0
.5
92±0.5 92±0.5
Air gap entire
cabinet width ≥ 25 cm2
The intermediate bottom which is to prevent
accidental contact with live parts must be
removable by unscrewing from beneath.
Fan
Dial
GK46TIPS …, GK46TIMPS …
30
≥ 5
123 B ≥ 200
≥ 15825
900
≥ 1
7.5 1
7.5
*C
≥ 8
0
A ≥
67.5
B ≥
15
50
Ventilation
discharge
Ventilation
intake
A Necessary space below
work surface for ventilation
Ventilation
intake for
nic
he 8
25
Drawer
GK16TIYS.1F, GK26TIYS.1F
30
≥
5
≥ 15 600 ≥ 1
7.5
56
.1
A ≥
73
.6
Drawer
Fan
A Necessary space below work surface for ventialtionAir gap over
entire width of cabinet element ≥ 25 cm²
* Required for flush appliancesA Necessary space below the worktop for the ventilation of the applianceB Cut-out in the side walls left and right for the ventilation of the applianceC Cut-out in the side walls for disassembly from below, only for flush version
7
V-ZUG Ltd Planning aid J001.059-12Industriestrasse 66, P.O. Box 59, 6301 ZugTel. +41 58 767 67 67, Fax +41 58 767 61 61
Kitchen appliances03.09.14
[email protected], www.vzug.com
42
7.8 Installation with protective plate
For more information, see section Accessories [➙ see page 106].
Requirements for optimal ventilation:
- front-facing air gap of ≥ 3 mm (with protective plate)
- distance of ≥ 17.5 mm between protective plate and ventilation opening
- worktop depth of ≥ 20 mm to ≤ 40 mm
- a supply of fresh air (≥ 15 mm air gap) is essential for the trouble-free operation of the hob
A protective plate cannot be installed with induction hobs that have dial controls.
GK26TI …, GK36TI …, GK46TI …
55.5
≥ 3
5..10
≥ 15600
≥ 1
7.5
50
30
A ≥
67.5
≤ 0.5
56
ø4
393
Drawer
Fan
Well-fitting seal over width of cabinet element
Air gap over entire width of cabinet element ≥ 17 cm2
Ventilation protective plate
A Necessary space below
work surface for ventilation
GK46TIABS …, GK46TIAKS …, GK46TIMAS …
600
30
*C
≥ 5
5
* Required for flush appliancesA Necessary space below the worktop for the ventilation of the applianceC Cut-out in side walls for disassembly from below, only for flush version
7
V-ZUG Ltd Planning aid J001.059-12Industriestrasse 66, P.O. Box 59, 6301 ZugTel. +41 58 767 67 67, Fax +41 58 767 61 61
Kitchen appliances03.09.14
[email protected], www.vzug.com
43
GK56TIMS …
30
*C
≥ 5
5
825
900
Fans
for
nic
he
82
5
GK46TIPS …, GK46TIMPS …
55.5
5..10
ø4
≥ 3
≥ 15
825
900
A ≥
67.5
B ≥
15
*C
≥ 8
2
≥ 1
7.5
(50)
30
≤ 0.5
123 B ≥ 200
56 393
Ventilation protective plate
for
nic
he 8
25
Drawer
Ventilation
intake
Ventilation
discharge
A Necessary space below
work surface for ventilation
Ventilationintake
GK16TIYS.1F, GK26TIYS.1F
61.6
≥ 3
5..10
≥ 15
600≥ 1
7.5
30
(56.1
)
*C
55
A ≥
73.6
≤ 0.5
56
ø4
393Drawer
Fan
Well-fitting seal over width of cabinet element
Air gap over entire width of cabinet element ≥ 17 cm2
Ventilation protective plate
A Necessary space below
work surface for ventilation
* Required for flush appliancesA Necessary space below the worktop for the ventilation of the applianceB Cut-out in the side walls left and right for the ventilation of the applianceC Cut-out in side walls for disassembly from below, only for flush version
7
V-ZUG Ltd Planning aid J001.059-12Industriestrasse 66, P.O. Box 59, 6301 ZugTel. +41 58 767 67 67, Fax +41 58 767 61 61
Kitchen appliances03.09.14
[email protected], www.vzug.com
44
7.9 Installing above oven / steam cooker
It is not possible to install an oven below the following hobs: GK46TIMPS…, GK46TIPS…, GK56TIMS…, GK26ID…,GK46ID…, GK46IABD…
With the use of a ventilation grille (Accessories [➙ see page 106])Type of construction 60-381: Combi-Steam SL, Steam S, Hotair HSEType of construction 60-450: Combi-Steam XSL, Combair XSL, Combair XSEType of construction 60-600: Combair-Steam S, Combair-Steam N, Combair SLP, Combair SL, Combair SEP, Combair SE
Y
Cvar.
≥ 15
≤ 3
0
≥ 2
0
D3
BE
A
AA
A
= =
600
~230
35
C
5–6
≥ 2
0
3D
≤ 5
0
E
≥ 6
7,5
Ventilation grille
(see «Accessories»)
Cut-out in the rear
panel, if required
Detail Y
A Possible mains supply connectionsB Mounting cut-outsC Appliance height: 59.8 cm (type of construction: 60-600), 37.8 cm (type of construction: 60-381), 45.4 cm (type of construc-
tion: 60-450)D Niche height: 63.5 cm (type of construction: 60-600), 41.6 cm (type of construction: 60-381), 45.0 cm (type of construction:
60-450)E Cut-outs in side walls for hobs larger than niche width
7
V-ZUG Ltd Planning aid J001.059-12Industriestrasse 66, P.O. Box 59, 6301 ZugTel. +41 58 767 67 67, Fax +41 58 767 61 61
Kitchen appliances03.09.14
[email protected], www.vzug.com
45
8 Toptronic glass ceramic hobs
8.1 General notes
The distance between the underside of the hob tray and any part of the cabinet beneath that is made of combustible materialmust be ≥ 20 mm. The distance from the hob cut-out to flammable walls (left, right and rear) must be ≥ 50 mm, for flushmounted ≥ 41.5 mm, for GK45TEPSF ≥ 55 mm.If a drawer is installed directly underneath – and if the tray can be reached from below without the aid of tools – a guardmust be used. The protective plate-set (see Accessories [➙ see page 106]) is recommended.
Efficient repairs can only be guaranteed if it is possible to uninstall the whole appliance at any time without causing anydamage.
The layout of the hobs to be installed may differ from the hobs illustrated here!
Dear Customer
This planning aid contains the dimensions of all our current glass ceramic hobs.
Since April 2013, most of the flush Toptronic hobs require larger cut-out dimensions and other corner radii. If you own an appliancewhich was manufactured before April 2013, please make sure that you do select the correct cut-out dimensions.You will find the cut-out dimensions for flush Toptronic hobs in the section Glass ceramic hobs for the replacement market [➙ seepage 53].
Our product range naturally still includes hobs which have the previous cut-out dimensions.
Thank you for reading this information
Your V-ZUG Ltd
8.2 Electrical connection data
General information on the electrical connections and an overview of the positions can be found in section Overview ofconnections, ranges and dimensions [➙ see page 5].
Type Mains connection Fuse Mains cable CountryGK25TE …
220-240 V~ 50 Hz
16 A
1.7 m, without plug
CNGK45TEBS …GK35TEPS …,GK45TEAS …,GK45TEPS …
32 A AU, CN, GB, HK, NO, SG
GK45TEBS …GK35TEPS …,GK45TEAS …,GK45TEPS …
380–415 V~ 2N 50 Hz 16 A EU, IL LB, RU, UA TR
8
V-ZUG Ltd Planning aid J001.059-12Industriestrasse 66, P.O. Box 59, 6301 ZugTel. +41 58 767 67 67, Fax +41 58 767 61 61
Kitchen appliances03.09.14
[email protected], www.vzug.com
46
8.3 Framed installation
A width of 600 mm is recommended for the base unit.
- «Click-in» assembly- Outer corner radii of cut-out, aim for ≤ 10 mm- Corner radii of appliance 8 mm
GK25TE (005)
≥ 50
≥ 50
490 ±
1
600
265 ±1
A275
Y
Y
289
514
81
H
Self-tapping screws
Ri
Ra
H≥
20 *
Y – Y
Drawer/Cabinet
* The clearance space must be provided!
Type ADepends on producer
H
GK25TE ≥ 30 mm 39.2 mm
A Worktop depth (in combination with directly built-under oven)H Measurement from the top side of the worktop to the underside of the hob tray1 Thermal shielding plate set Accessories [➙ see page 106]
8
V-ZUG Ltd Planning aid J001.059-12Industriestrasse 66, P.O. Box 59, 6301 ZugTel. +41 58 767 67 67, Fax +41 58 767 61 61
Kitchen appliances03.09.14
[email protected], www.vzug.com
47
GK45TEAS (977), GK45TEASC (977) GK45TEBS.1 (032), GK45TEBS.1C (032)
B60
0
A
490 ±
1
≥ 50
≥ 50
750 ±1
600
81
H
774
514
Y
YX
X
Self-tapping screws
600
600
560 ±1
490 ±
1
≥ 50
≥ 50
A
H
584
514
1
8
X
X
Self-tapping screws
H≥
20
*
Y – Y
Drawer/Cabinet
* The clearance space must be provided!
Type ADepends on producer
B H
GK45TEAS, GK45TEASC ≥ 30 mm 65.2 mm 45.2 mmGK45TEBS.1, GK45TEBS.1C 66.5 mm 46.5 mm
A Worktop depth (in combination with directly built-under oven)B Cut-out in side walls (with/without thermal shielding plate set)H Measurement from the top side of the worktop to the underside of the hob tray1 Thermal shielding plate set Accessories [➙ see page 106]
8
V-ZUG Ltd Planning aid J001.059-12Industriestrasse 66, P.O. Box 59, 6301 ZugTel. +41 58 767 67 67, Fax +41 58 767 61 61
Kitchen appliances03.09.14
[email protected], www.vzug.com
48
GK35TEPS (31032), GK35TEPSC (31032) GK45TEPS (976), GK45TEPSC (976)
8
774
444
H
Y
Y
420
±1
≥ 50
≥ 50
750 ±1
600
B
600
A
Z
Z
1
Self-tapping screws
A
886 ±1
386 ±
1
900/825≥ 7
0
≥ 7
0
Y
Y
910
8
1
410
2
X
X
Self-tapping screws
Y – Y
≥ 2
0 *
B
Drawer/Cabinet
B
825±1
≥ 20 *
Z – Z
H
Drawer/
Cabinet
Side wall
* The clearance space must be provided!
Type ADepends on producer
B H
GK35TEPS, GK45TEPS ≥ 25 mm ≥ 63.5 mm 43.5 mmGK35TEPSC, GK45TEPSC ≥ 30 mm ≥ 66.5 mm 46.5 mm
A Worktop depth (in combination with directly built-under oven)B Cut-out in side walls (with/without thermal shielding plate set)H Measurement from the top side of the worktop to the underside of the hob tray1 Front and rear struts are reinforced on the underside. The strut width is determined by the producer of the stone
worktop. The minimum strut width can vary according to the property of the stone.2 Thermal shielding plate set Accessories [➙ see page 106]
8
V-ZUG Ltd Planning aid J001.059-12Industriestrasse 66, P.O. Box 59, 6301 ZugTel. +41 58 767 67 67, Fax +41 58 767 61 61
Kitchen appliances03.09.14
[email protected], www.vzug.com
49
8.4 Flush installation
If a drawer is installed directly underneath – and if the tray can be reached from below without the aid of tools – an inter-mediate base must be used.
A width of 600 mm is recommended for the base unit.Access to the hob from below must be guaranteed. For servicing, the hob control unit can be exchanged from below.
GK25TE.1F (31023)
≥ 4
1.5
≥ 4
1.5 600
275
A
507 ±
1
287 ±1Z
Y
Y
501
X
H
Ri 281
X
C D
Ra
R0–5
8.5 0-1
8.5 0-0.5
Detail Z
8.5
0/+
18.5
0/+
1
Steel angle bonded
or screw mounted
X – X
≥ 2
0 *
275/500
B
H
Side wall
Drawer/Cabinet
Y – Y
H≥
20 *
B
Side wall
Drawer/Cabinet
* The clearance space must be provided!
Type ADepends on producer
B C/D H Corner radiusRa/Ri
GK25TE.1F ≥ 30 mm ≥ 82 mm 270/490 mm 47.5 mm 5/1.5 mm
A Worktop depth (in combination with directly built-under oven)B Minimum measurement in side wall area for disassembly of hob trayH Measurement from the top side of the worktop to the underside of the hob trayRi Corner radii of applianceRa Outer corner radii of cut-out
8
V-ZUG Ltd Planning aid J001.059-12Industriestrasse 66, P.O. Box 59, 6301 ZugTel. +41 58 767 67 67, Fax +41 58 767 61 61
Kitchen appliances03.09.14
[email protected], www.vzug.com
50
GK45TEAS.1F (31026) GK45TEBS.2F (31028)
761
501
H
Y
Y
Ri507
±1
≥ 4
1.5
≥ 4
1.5
767 ±1
600
Z
600
A
B
X
X
571
501
600
577 ±1
507
±1
≥ 4
1.5
≥ 4
1.5
Z
600
A
H
Ri
C D
Ra
R0–5
8.5 0-1
8.5 0-0.5
Detail Z
8.5
0/+
18.5
0/+
1
Steel angle bonded
or screw mounted
X – X
≥ 2
0 *
275/500
B
H
Side wall
Drawer/Cabinet
Y – Y
H≥
20 *
B
Side wall
Drawer/Cabinet
* The clearance space must be provided!
Type ADepends on producer
B C/D H Corner radiusRa/Ri
GK45TEAS.1F ≥ 30 mm ≥ 82 mm 750/490 mm 47.5 mm 5/1.5 mmGK45TEBS.2F 560/490 mm
A Worktop depth (in combination with directly built-under oven)B Minimum measurement in side wall area for disassembly of hob trayH Measurement from the top side of the worktop to the underside of the hob trayRi Corner radii of applianceRa Outer corner radii of cut-out
8
V-ZUG Ltd Planning aid J001.059-12Industriestrasse 66, P.O. Box 59, 6301 ZugTel. +41 58 767 67 67, Fax +41 58 767 61 61
Kitchen appliances03.09.14
[email protected], www.vzug.com
51
GK35TEPSF (31032) GK45TEPSF (976)
744
414
H420
±1
≥ 4
1.5
≥ 4
1.5
750 ±1
600
A
B≥ 5
30
Z
YY
Ri
A
886 ±1
386
±1
900/825
Z
≥ 7
0
≥ 7
0
1
YY
380
880
Ri
H
C D
Ra
R0–5
8.5 0-1
8.5 0-0.5
Detail Z
8.5
0/+
18.5
0/+
1
Steel angle bonded
or screw mounted
B
825≥ 20 *
Y – Y
H
Drawer/Cabinet
Side wall
* The clearance space must be provided!
Type ADepends on producer
B C/D H Corner radiusRa/Ri
GK35TEPSF ≥ 30 mm ≥ 82 mm 733/403 mm 47.5 mm 5/1.5 mmGK45TEPSF 869/369 mm
A Worktop depth (in combination with directly built-under oven)B Minimum measurement in side wall area for disassembly of hob trayH Measurement from the top side of the worktop to the underside of the hob trayRi Corner radii of applianceRa Outer corner radii of cut-out1 Front and rear struts are reinforced on the underside. The strut width is determined by the producer of the
stone worktop. The minimum strut width can vary according to the property of the stone.
8
V-ZUG Ltd Planning aid J001.059-12Industriestrasse 66, P.O. Box 59, 6301 ZugTel. +41 58 767 67 67, Fax +41 58 767 61 61
Kitchen appliances03.09.14
[email protected], www.vzug.com
52
9 Glass ceramic hobs for the replacement market
9.1 Appliances for the replacement market – induction
For general notes, electrical connection data and how to operate the appliance, see section Glass ceramic hobs – induc-tion, wok, teppanyaki [➙ see page 28].Hob must be removable from below!
Corner radii of appliance 11 mm
GK16TIWSF (87A)
H
384
477
390 ±1
≥ 5
5
≥ 5
5
600
483
±1
A
Z
600 ≥ 400
≥ 1
46 *
Ri
1
C D
Ra
R0–5
8.5 0
-1
8.5 0
-0.5
8.5
0/+
18.5
0/+
1
Steel angle bonded or screw mounted
Detail Z
* The clearance space must be provided!
Type ADepends on producer
C/D H Corner radiusRa/Ri
GK16TIWSF ≥ 30 mm 373/466 mm 128.5 mm 14/11 mm
A Worktop depth (in combination with directly built-under oven)B Necessary clearance space for service requirementsH Measurement from the top side of the worktop to the underside of the hob (ventilation openings)Ri Corner radii of applianceRa Outer corner radii of cut-out1 The intermediate base must be removable from below.
9
V-ZUG Ltd Planning aid J001.059-12Industriestrasse 66, P.O. Box 59, 6301 ZugTel. +41 58 767 67 67, Fax +41 58 767 61 61
Kitchen appliances03.09.14
[email protected], www.vzug.com
53
GK16TIYSF (85A) GK26TIYSF (86A)
H
384
477
Y
Y
600 ≥ 400
≥ 5
5600
≥ 5
5
Z ≥
73
.6 *
≥ 300
483
±1
390 ±1
A
Ri
for
ve
ntila
tio
n
On both sides
for technical
reasons
477
547
H
Y
Y
600 A
Z
≥ 5
5
600
≥ 5
5
≥ 300
553 ±1
483
±1
Ri
On both sides
for technical
reasons
for
ventila
tion
≥
73.6
*
Y – Y
H≥
17.5
*
B
Drawer/Cabinet
Side wall
C D
Ra
R0–5
8.5 0
-1
8.5 0
-0.5
8.5
0/+
18.5
0/+
1
Steel angle bonded or screw mounted
Detail Z
* The clearance space must be provided!
Type ADepends on producer
B C/D H Corner radiusRa/Ri
GK16TIYSF ≥ 30 mm ≥ 55 mm 373/466 mm 57.1 mm 14/11 mmGK26TIYSF 536/466 mm
A Worktop depth (in combination with directly built-under oven)B Necessary clearance space for service requirementsH Measurement from the top side of the worktop to the underside of the hob (ventilation openings)Ri Corner radii of applianceRa Outer corner radii of cut-out
9
V-ZUG Ltd Planning aid J001.059-12Industriestrasse 66, P.O. Box 59, 6301 ZugTel. +41 58 767 67 67, Fax +41 58 767 61 61
Kitchen appliances03.09.14
[email protected], www.vzug.com
54
GK26TIMSF (84A) GK36TISF (008)
477
272
Y
Y≥ 55
≥ 55
483 ±1
600278±1
A275
Ri
H
Z
483
±1
553 ±1
600
≥ 5
5
≥ 5
5
A
600
547
477
Y
Y
Ri
Z
H
Y – Y
H≥
17.5
*
B
Drawer/Cabinet
Side wall
C D
Ra
R0–5
8.5 0
-1
8.5 0
-0.5
8.5
0/+
18.5
0/+
1
Steel angle bonded or screw mounted
Detail Z
* The clearance space must be provided!
Type ADepends on producer
B C/D H Corner radiusRa/Ri
GK26TIMSF ≥ 30 mm ≥ 55 mm 261/466 mm 50.0 mm 14/11 mmGK36TISF 536/466 mm 51.7 mm
A Worktop depth (in combination with directly built-under oven)B Necessary clearance space for service requirementsH Measurement from the top side of the worktop to the underside of the hob (ventilation openings)Ri Corner radii of applianceRa Outer corner radii of cut-out
9
V-ZUG Ltd Planning aid J001.059-12Industriestrasse 66, P.O. Box 59, 6301 ZugTel. +41 58 767 67 67, Fax +41 58 767 61 61
Kitchen appliances03.09.14
[email protected], www.vzug.com
55
GK46IDF (95A), GK46TIMSF (88A) GK46IABDF (96A), GK46TIABSF (028)
483
±1
553 ±1
600
≥ 5
5
≥ 5
5
A
600
547
477
Y
Y
Ri
Z
H
483
±1
≥ 5
5
≥ 5
5
600
743 ±1
600
A
Z
477
737Y
Y
Ri
1
H
Y – Y
H≥
17.5
*
B
Drawer/Cabinet
Side wall
C D
Ra
R0–5
8.5 0
-1
8.5 0
-0.5
8.5
0/+
18.5
0/+
1
Steel angle bonded or screw mounted
Detail Z
* The clearance space must be provided!
Type ADepends on producer
B C/D H Corner radiusRa/Ri
GK46IDF, GK46TIMSF ≥ 30 mm ≥ 55 mm 536/466 mm 51.7 mm 14/11 mmGK46IABDF, GK46TIABSF 726/466 mm 50.0 mm
A Worktop depth (in combination with directly built-under oven)B Necessary clearance space for service requirementsH Measurement from the top side of the worktop to the underside of the hob (ventilation openings)Ri Corner radii of applianceRa Outer corner radii of cut-out1 For symmetrical installation, it is not necessary to cut out the side walls.
9
V-ZUG Ltd Planning aid J001.059-12Industriestrasse 66, P.O. Box 59, 6301 ZugTel. +41 58 767 67 67, Fax +41 58 767 61 61
Kitchen appliances03.09.14
[email protected], www.vzug.com
56
GK56TIMSF (89A)
477
880
H
900
600
886 ±1
≥ 5
5
483
±1
≥ 5
5
Z1
B
825
=
=
≥ 5
38
2
Ri Y – Y
H≥
17.5
*
B
Drawer/Cabinet
Side wall
C D
Ra
R0–5
8.5 0
-1
8.5 0
-0.5
8.5
0/+
18.5
0/+
1
Steel angle bonded or screw mounted
Detail Z
* The clearance space must be provided!
Type ADepends on producer
B C/D H Corner radiusRa/Ri
GK56TIMSF ≥ 30 mm ≥ 55 mm 869/466 mm 53.3 mm 5/1.5 mm
A Worktop depth (in combination with directly built-under oven)B Necessary clearance space for service requirementsH Measurement from the top side of the worktop to the underside of the hob (ventilation openings)Ri Corner radii of applianceRa Outer corner radii of cut-out1 For symmetrical installation, it is not necessary to cut out the side walls2 Front and rear struts are reinforced on the underside. The strut width is determined by the producer of the stone
worktop. The minimum strut width can vary according to the property of the stone.
9
V-ZUG Ltd Planning aid J001.059-12Industriestrasse 66, P.O. Box 59, 6301 ZugTel. +41 58 767 67 67, Fax +41 58 767 61 61
Kitchen appliances03.09.14
[email protected], www.vzug.com
57
9.2 Appliances for the replacement market – Toptronic
For general notes, electrical connection data and how to operate the appliance, see section Toptronic glass ceramic hobs[➙ see page 46].If a drawer is installed directly underneath – and if the tray can be reached from below without the aid of tools – an inter-mediate base must be used.
A width of 600 mm is recommended for the base unit.Access to the hob from below must be guaranteed. For servicing, the hob control unit can be exchanged from below.Corner radii of appliance 11 mm
GK45TEBS.1F (032) GK45TEASF (977)
547
477X
X
600
553 ±1
483
±1
≥ 5
5
≥ 5
5
Z
600
A
H
Ri
737
X
X
477
483
±1
≥ 5
5
≥ 5
5
743 ±1
600
Z
600
A
B
H
Ri
X–X
H≥
20 *
B
Side wall
Drawer/CabinetC D
Ra
R0–5
8.5 0-1
8.5 0-0.5
Detail Z
8.5
0/+
18.5
0/+
1
Steel angle bonded
or screw mounted
* The clearance space must be provided!
Type ADepends on producer
B C/D H Corner radiusRa/Ri
GK45TEBS.1F ≥ 30 mm ≥ 82 mm 536/466 mm 47.5 mm 14/11 mmGK45TEASF 726/466 mm
A Worktop depth (in combination with directly built-under oven)B Minimum measurement in side wall area for disassembly of hob trayH Measurement from the top side of the worktop to the underside of the hob trayRi Corner radii of appliance Ra Outer corner radii of cut-out
9
V-ZUG Ltd Planning aid J001.059-12Industriestrasse 66, P.O. Box 59, 6301 ZugTel. +41 58 767 67 67, Fax +41 58 767 61 61
Kitchen appliances03.09.14
[email protected], www.vzug.com
58
10 Examples for combined appliance installation
Size B A ± 1
30 + 40 388.5 674 ± 1 30 + 60 575.5 861 ± 1
Size B A ± 1
40 + 40 388.5 777 ± 1 40 + 60 575.5 964 ± 1
Size B A ± 1
30 + 40 + 40 387 1061 ± 1 30 + 60 + 40 574 1248 ± 1
Size B A ± 1
40 + 40 + 40 387 1164 ± 1 40 + 60 + 40 574 1351 ± 1
Y-Y
Intermediate supportset H63789
281
B
3
285.5
A ±1
384
B
3
388.5
A±1
281
B
384 3
3
285.5
388.5
A±1
384
384
B
3
3
388.5
388.5
501
≥ 600 507±1
≥ 41.5
≥ 41.5
501
507±1
≥ 41.5
≥ 41.5 ≥ 600
501
507±1
≥ 600
≥ 41.5
≥ 41.5
501
507±1
≥ 600
≥ 41.5
≥ 41.5
A±1
≥ 41.5
8.5 0
-1
Y
Y
X
X
H
X-X
Type
Standard
H
GK16TIWSF, GK16TIWS.1F
6.5 mm
7.7 mm
Cementing-in instructions J402.80
8.5
0 -1
10
V-ZUG Ltd Planning aid J001.059-12Industriestrasse 66, P.O. Box 59, 6301 ZugTel. +41 58 767 67 67, Fax +41 58 767 61 61
Kitchen appliances03.09.14
[email protected], www.vzug.com
59
11 Gas hobs & lava grills
11.1 Gas hobs
When a range hood is installed above the gas hob, a minimum distance of 750 mm must be observed.
≥ 750
≥ 450
≥ 5
GK11TG, GK11TTG
520
45
57
62
44
43
≥ 50
≥ 100*≥ 600
≥ 3
0
270+2
490-
500+2
302
80
≥ 9
5
87
≥ 5
≥ 25
10
–1
5050
30
–5
0
* Minimum distance from mounting cut-out to the wall
** Position of gas connection in cut-out
Designation Art. no. Mains connec-tion
Fuse Rated load Gas type Connectioncable
Country
GK11TG 798.3.49 220-240 V~50/60 Hz
3 A 1 W Natural gas H/E/(L)20 (25) mbar
1 m, without plug RU/UA, UK, LB,HK, SG, TR, IT
798.3.69 Natural gas 1 kPa 1 m, AU plug AUGK11TTG 851.3.89 Town gas G110
8 mbar1 m, BS plug HK, SG
11
V-ZUG Ltd Planning aid J001.059-12Industriestrasse 66, P.O. Box 59, 6301 ZugTel. +41 58 767 67 67, Fax +41 58 767 61 61
Kitchen appliances03.09.14
[email protected], www.vzug.com
60
GK21TG, GK21TTG
520
302
47
62
44
43
≥ 50
≥ 3
0≥ 600490-
500+2
270+2
≥ 100*
45
≤ 1
50
≥ 1
0 ≥ 25
45
30-5
0
62
≥ 8
0 ≥ 5
GK1121TGCN
520
45
57
62
44
43
≥ 50
≥ 100*
≥ 600
≥ 3
0
576+2
490-
500+2
604
Connection strip
1 × H64140
80
≥ 9
5
87
≥ 5
≥ 25
10–15050
30–50
≤ 1
50
≥ 1
0 ≥ 25
45
30-5
0
62
≥ 8
0 ≥ 5
* Minimum distance from mounting cut-out to the wall
** Position of gas connection in cut-out
Designation Art. no. Mainsconnec-
tion
Fuse Rated load Gas type Connectioncable
Country
GK21TG 797.3.49 220-240 V~50/60 Hz 3 A 1 W
Natural gasH/E/(L)
20 (25) mbar
1 m, without plug RU/UA, UK, LB,HK, SG, TR, IT
GK21TTG 302.3.89 Town gas G1108 mbar
SG, HK
GK1121TGCN 31035.67.200 220 V~50 Hz
Natural gasH/E/(L)
20 (25) mbar
2 × 1 m, 2 × CN plug
CN
11
V-ZUG Ltd Planning aid J001.059-12Industriestrasse 66, P.O. Box 59, 6301 ZugTel. +41 58 767 67 67, Fax +41 58 767 61 61
Kitchen appliances03.09.14
[email protected], www.vzug.com
61
GK41TG
602
520
45
47
53
≥ 50≥
30≥ 600
26
21
≥ 100*490
±1560±1
≤ 1
50
≥ 1
0
≥ 25
45
30-5
0
50
≥ 8
0 ≥ 5
35
GK51TPG
520
912
45
≥ 150*
≥ 3
0
≥ 50
595
7
42
26
≥ 600490
±1850±1
≤ 1
50
≥ 1
0 ≥ 25
45
30-5
0
≥ 8
0 ≥ 5
* Minimum distance from mounting cut-out to the wall
** Position of gas connection in cut-out
Designation Art. no. Mains connec-tion
Fuse Rated load Gas type Connectioncable
Country
GK41TG 717.3.49 220-240 V~50/60 Hz
3 A 1 W Natural gas H/E/(L)20 (25) mbar
1 m, without plug RU/UA, UK, LB,HK, SG, TR, ITGK51TPG 701.3.49
701.3.69 Natural gas 1 kPa 1 m, AU plug AU
11
V-ZUG Ltd Planning aid J001.059-12Industriestrasse 66, P.O. Box 59, 6301 ZugTel. +41 58 767 67 67, Fax +41 58 767 61 61
Kitchen appliances03.09.14
[email protected], www.vzug.com
62
11.2 Lava grill
GK11TKLG
≥ 100*
≥ 3
0≥ 50
490-500
+2
520
≥ 6
00
302
108
Dra
in c
ock
~128*
≥ 60-5
0270 +2
17
3
* Minimum distance from cut-out for trough to wall
Designation Art. no. Mains connec-tion
Rated load Mains cable Connection cable Country
GK11TKLG 98A.3.30 220–240 V~50/60 Hz
13 A 2400 W 1 m, without plug RU/UA, UK, LB, HK, SG, TR, CN
11.3 2-zone induction hob
GK21TI
53
≥ 600
≥ 40
≥ 50
≥ 60/50
520
302
270 +2-0
490-
500+2
-0
20/3
0*
* with oven
Designation Art. no. Mains connec-tion
Fuse Rated load Connection cable Country
GK21TI 834.3.89 220-240 V~50/60 Hz
16 A 3700 W 1.1 m, without plug RU/UA, UK, LB, HK, SG, TR, CN
11
V-ZUG Ltd Planning aid J001.059-12Industriestrasse 66, P.O. Box 59, 6301 ZugTel. +41 58 767 67 67, Fax +41 58 767 61 61
Kitchen appliances03.09.14
[email protected], www.vzug.com
63
11.4 Installation examples for combined gas edition arrangement
Arrangement A (1 × H64140)
30
28830
30288
30288
490 / 500
600
50
R3
≥ 50
30 576+230
36
H64140
Connection strip
Arrangement B (2 × H64140)
30
30
30
30 882+23030
30288
30288
30306
490 / 500
600
50
R3
≥ 5036
H64140
Connection strip
11
V-ZUG Ltd Planning aid J001.059-12Industriestrasse 66, P.O. Box 59, 6301 ZugTel. +41 58 767 67 67, Fax +41 58 767 61 61
Kitchen appliances03.09.14
[email protected], www.vzug.com
64
Arrangement C (3 × H64140)
30
30 1188+23030
30
30
30
30
30288
30288
30306490 / 500
600
50
R3
≥ 50
30306
36
H64140
Connection strip
Arrangement D (1 × H64140)
30
876+2
60
30
30288
490 / 500
600
50
R3
≥ 50
60588
60
36
H64140
Connection strip
11
V-ZUG Ltd Planning aid J001.059-12Industriestrasse 66, P.O. Box 59, 6301 ZugTel. +41 58 767 67 67, Fax +41 58 767 61 61
Kitchen appliances03.09.14
[email protected], www.vzug.com
65
Arrangement E (1 × H64140)
30
1186+2
90
30
30288
490 / 500
600
50
R3
≥ 50
90898
90
36
H64140
Connection strip
Arrangement F (2 × H64140)
30
60
30
30288
490 / 500
600
50
R3
≥ 50
60588
60
90898
30306
30
90
1182+230
30 90 1492+230
36
H64140
Connection strip
11
V-ZUG Ltd Planning aid J001.059-12Industriestrasse 66, P.O. Box 59, 6301 ZugTel. +41 58 767 67 67, Fax +41 58 767 61 61
Kitchen appliances03.09.14
[email protected], www.vzug.com
66
Arrangement G (2 × H64140)
30
60
30
30288
490 / 500
600
50
R3
≥ 50
60588
60
90916
30
90
1182+230
30 90 1492+230
30288
36
H64140
Connection strip
11
V-ZUG Ltd Planning aid J001.059-12Industriestrasse 66, P.O. Box 59, 6301 ZugTel. +41 58 767 67 67, Fax +41 58 767 61 61
Kitchen appliances03.09.14
[email protected], www.vzug.com
67
12 Range hoods
Technical information on the range hoods can be found in the document J328.35 «TechInfo for range hoods» and the pricelist.
12.1 General notes
If other firing systems are being used at the same time (e.g. wood, gas, oil or coal fired heating appliances), safe operation isonly possible providing a room negative pressure of 4 Pa (0.04 mbar) is not exceeded at the location of the appliance.Risk of toxic fumes! An adequate flow of fresh air must be guaranteed e.g. via non-closable openings in doors or windowsand in combination with an air-intake/exhaust-air wall box or by other technical means.
If the appliance is installed over gas hobs, each cooking zone must be fitted with an ignition fuse and the minimum distances(see «Distance above hob») must be adhered to.
Efficient repairs can only be guaranteed if it is possible to uninstall the whole appliance at any time without causing anydamage.
Extraction mode
The extracted air must not be fed into a chimney which is used for exhausting fumes from appliances burning gas or otherfuels.Observe the local fire regulations.
Installation notes• In addition to the correct dimensioning of the exhaust duct, it is also necessary to ensure a sufficient inflow of fresh air.
Exhaust air needs fresh air.
• Avoid routing the exhaust duct to the side through the flue casing.
• Planning features for non-destructive de-installation and maintenance of the appliance:
– Do not route telescopic casing in suspended ceilings.
– Avoid silicon joints between the telescopic casing and the appliance.
– All plastering, plasterboarding, wall papering or painting work is to be carried out prior to installing the appliance.
12
V-ZUG Ltd Planning aid J001.059-12Industriestrasse 66, P.O. Box 59, 6301 ZugTel. +41 58 767 67 67, Fax +41 58 767 61 61
Kitchen appliances03.09.14
[email protected], www.vzug.com
68
12.2 Island hoods
Applicable to the following hoods:
• Telescopic casing (adjustable) is supplied in up to 4 basic heights A.
• For activation of external motor flaps, roof ventilators, room fans, etc., see document P60.008.
• Mains connection directly above range hood, connection cable 1.2 m with plug.
DI-Premira DIPQ10 (63007), DIPQ13 (63006)Operatingmode
Extraction/recirculation
Mains connec-tion
220-240 V~ 50/60 Hz, 138.8 W Illumination 4 × 2.2 W Fan speeds 4
Noise level 41-64 dB(A) Fuse 10 A Motor 1 × 130 W Weight ~31.5/35 kgOptions connection (optional) Max. 300 W
Drilling plan (view X)
200
100
00 200 400 600
0
10
20
30
40
Flow volume [m³/h]
pst
at [
Pa]
p stat [m
m W
S/C
E]
300
400
3
2
1
4 intensive
Detail Y
24
10
1
239
55
BA
ø 150
1000/1300 700
h
X
330330
¹
324.8297
240.4180
80
240.4
293.5
324.820
180
55 1
00
R80
h:Extraction/recirculation 2.5 kg: 420 mm
Extraction with metal ring: 477 mmRecirculation 5 kg: 565 mm
¹ For recirculation air (see detail Y):- Air outlet left/right: always possible- Air outlet front/back:
Telescopic casing extracted airAvailable in 3 basic heights A:475-670 mm (standard)675-910 mm (medium)915-1305 mm (long)
for 2.5 kg activated charcoal if A ≥ 605 mmfor 5 kg activated charcoal if A ≥ 750 mm
Telescopic casing recirculation airAvailable in 4 basic heights A:
Distance above hobMinimum distance B
565-645 mm: 2.5 kg activated charcoal (standard)650-780 mm: 5 kg activated charcoal (standard)785-995 mm: 5 kg activated charcoal (medium)1000-1410 mm: 5 kg activated charcoal (long)
For electric hob: 500 mmFor gas hob: 650 mm
12
V-ZUG Ltd Planning aid J001.059-12Industriestrasse 66, P.O. Box 59, 6301 ZugTel. +41 58 767 67 67, Fax +41 58 767 61 61
Kitchen appliances03.09.14
[email protected], www.vzug.com
69
DI-Mistral DI-M10 (996), DI-M12 (997)Operatingmode
Extraction/recirculation
Mains connec-tion
220-240 V~ 50/60 Hz, 640 W Illumination 4 × 20 W, 12 V~ Fan speeds 4
Noise level 40-59 dB(A) Fuse 10 A Motor 1 × 260 W Weight ~42/48 kgOptions connection Max. 300 W
Drilling plan (view X)
0 200 400 600 800
400
300
200
100
0
40
30
20
10
0
1
23
4
pst
at [
mm
WS
/CE
]
pst
at [
Pa
]
Flow volume [m³/h]
Intensive
25
10
0
Detail Y
166
~4
60
68
BA
ø 150
1000/1200
700
44
0
X
299257
ø 10
ø 102
15
16
4
88
25
7
207
299
235
For recirculation
air, see detail Y
for air outlet
Telescopic casing extracted airAvailable in 3 basic heights A:
Telescopic casing recirculation airAvailable in 3 basic heights A:
Distance above hobMinimum distance B
550-745 mm (standard)750-1000 mm (medium)1000-1250 mm (long)
600-745 mm (standard)750-1000 mm (medium)1000-1250 mm (long)
For electric hob: 600 mmFor gas hob: 750 mm
DI-B10 (816), DI-B12 (63008)Operatingmode
Extraction/recirculation
Mains connec-tion
220-240 V~ 50/60 Hz, 640 W Illumination 4 × 20 W, 12 V~ Fan speeds 4
Noise level 40-59 dB(A) Fuse 10 A Motor 1 × 260 W Weight ~36 kgOptions connection Max. 300 W
Drilling plan (view X)
0 200 400 600 800
400
300
200
100
0
40
30
20
10
0
1
23
4
pst
at [
mm
WS
/CE
]
pst
at [
Pa
]
Flow volume [m³/h]
Intensive
25
10
0
Detail Y
166
68
BA
ø 150
1000/1200 700
44
0
X
299257
ø 10
ø 10
21
5
16
4
88
25
7
207
299
235
For recirculation
air, see Detail Y
for air outlets
Telescopic casing extracted airAvailable in 3 basic heights A:
Telescopic casing recirculation airAvailable in 3 basic heights A:
Distance above hobMinimum distance B
550-745 mm (standard)750-1000 mm (medium)1000-1250 mm (long)
600-745 mm (standard)750-1000 mm (medium)1000-1250 mm (long)
For electric hob: 600 mmFor gas hob: 750 mm
12
V-ZUG Ltd Planning aid J001.059-12Industriestrasse 66, P.O. Box 59, 6301 ZugTel. +41 58 767 67 67, Fax +41 58 767 61 61
Kitchen appliances03.09.14
[email protected], www.vzug.com
70
DI-B14 (821)Operatingmode
Extraction/recirculation
Mains connec-tion
220-240 V~ 50/60 Hz, 680 W Illumination 6 × 20 W, 12 V~ Fan speeds 4
Noise level 40-59 dB(A) Fuse 10 A Motor 1 × 260 W Weight ~45 kgOptions connection Max. 300 W
Drilling plan (view X)
0 200 400 600 800
400
300
200
100
0
40
30
20
10
0
1
23
4
pst
at [
mm
WS
/CE
]
pst
at [
Pa
]
Flow volume [m³/h]
Intensive
25
10
0
Detail Y
166
80
BA
X
299257
ø 10
ø 10
21
5
16
4
88
25
7
207
299
235
ø 150
45
3
1400 700
For recirculation
air, see Detail Y
for air outlets
Telescopic casing extracted airAvailable in 3 basic heights A:
Telescopic casing recirculation airAvailable in 3 basic heights A:
Distance above hobMinimum distance B
562-757 mm (standard)762-1012 mm (medium)1012-1262 mm (long)
612-757 mm (standard)762-1012 mm (medium)1012-1262 mm (long)
For electric hob: 600 mmFor gas hob: 750 mm
DI-SE10 (076), DI-SE12 (077)Operatingmode
Extraction/recirculation
Mains connec-tion
220-240 V~ 50/60 Hz, 455 W Illumination 4 × 20 W, 12 V~ Fan speeds 4
Noise level 44-64 dB(A) Fuse 10 A Motor 1 × 175 W Weight ~21/23 kgOptions connection Max. 200 W
Drilling plan (view X)
0 100 200 300 400 500 6000
100
200
300
400
500
2
10
10
20
30
40
50
pst
at [
mm
WS
/CE
]
pst
at [
Pa]
4
3
Flow volume [m³/h]
Intensive
Detail Y
36
77
135
273
276.5
236.4
190
14
8
25
222
2506001000/1200
B
60
A ²
316 ¹
X
277277
ø 150
458
¹ With metal ring: 356 mm² Grid spacing: 10 mm
For recirculation air,sett Detail Y for selsctable air outletleft/right or front/back
Telescopic casing extracted airAvailable in 3 basic heights A:
Telescopic casing recirculation airAvailable in 3 basic heights A:
Distance above hobMinimum distance B
550-750 mm (standard)750-905 mm (medium)905-1265 mm (long)
650-750 mm (standard)750-980 mm (medium)980-1340 mm (long)
For electric hob: 600 mmFor gas hob: 750 mm
12
V-ZUG Ltd Planning aid J001.059-12Industriestrasse 66, P.O. Box 59, 6301 ZugTel. +41 58 767 67 67, Fax +41 58 767 61 61
Kitchen appliances03.09.14
[email protected], www.vzug.com
71
12.3 Wall hoods
Applicable to the following hoods:
• Consider type of piping (straight or elbow).
• Telescopic casing (adjustable) available in up to 4 basic heights A.
• For activation of external motor flaps, roof ventilators, room fans, etc., see document P60.008.
• Connection directly behind telescopic casing, connection cable 1.2 m with plug.
Positions of electrical connections
The specified dimensions are valid for straight exhaust air piping. If exhaust air pipings with an elbow are used, the dimen-sions must be adapted accordingly.
Designation Connection from lower part ofappliance
Connection from centre Type of connection
DW-Premira Recirculation 2,5 kg & extraction:495 mm
Recirculation 5 kg: 645 mm
80 mm
Flush power socket 230 VDW-Forano
DW-Levantemin. 540 mm 80 mm
DW-Mistral, DW-Bora,DW-SMC, DW-SE
550 mm 56 mm
DW-Premira DWPQ12 (62006)Operatingmode
Extraction/recirculation
Mains connec-tion
220-240 V~ 50/60 Hz, 136.6 W Illumination 3 × 2.2 W Fan speeds 4
Noise level 41-64 dB(A) Fuse 10 A Motor 1 × 130 W Weight ~29 kgOptions connection (optional) Max. 300 W
110ø 150
42
0 ¹
/56
5 ²
/ 4
77
³
1198 550
BA
3303102501
14
00
¹/
54
8 ²
18055
600 ¹
/ 7
50
²
For recirculation air,see detail Yfor air outlet
200
100
00 200 400 600
0
10
30
40
Flow volume [m³/h]
pst
at [
Pa]
pst
at [
mm
WS
/CE
]
300
400
20
3
2
1
4 Intensive
¹ Extraction/recirculation 2.5 kg² Recirculation 5 kg³ Extraction with metal ring 2
4
10
1
Detail Y 34,7239
Use of stone cladding20 mm thick wall panels (granite, marble)are possible.
20
Telescopic casing extracted airAvailable in 3 basic heights A:460-660 mm (standard)660-875 mm (medium)875-1305 mm (long)
Telescopic casing recirculation airAvailable in 4 basic heights A:565-650 mm: 2.5 kg activated charcoal (standard)650-780 mm: 5 kg activated charcoal (standard)780-995 mm: 5 kg activated charcoal (medium)995-1425 mm: 5 kg activated charcoal (long)
Distance above hobMinimum distance BFor electric hob: 500 mmFor gas hob: 650 mm
12
V-ZUG Ltd Planning aid J001.059-12Industriestrasse 66, P.O. Box 59, 6301 ZugTel. +41 58 767 67 67, Fax +41 58 767 61 61
Kitchen appliances03.09.14
[email protected], www.vzug.com
72
DW-Premira DWPQ9 (62007)Operatingmode
Extraction/recirculation
Mains connec-tion
220-240 V~ 50/60 Hz, 134.4 W Illumination 2 × 2.2 W Fan speeds 4
Noise level 41-64 dB(A) Fuse 10 A Motor 1 × 130 W Weight ~25.5 kgOptions connection (optional) Max. 300 W
110ø 150
42
0 ¹
/56
5 ²
/ 4
77
³
898 550
BA
3303102501
14
00
¹/
54
8 ²
18055
For recirculation air, see detail Y
for air outlet
60
0 ¹
/7
50
²
200
100
00 200 400 600
0
10
30
40
Flow volume [m³/h]
pst
at [
Pa]
pst
at [
mm
WS
/CE
]
300
400
20
3
2
1
4 Intensive
¹ Extraction/recirculation 2.5 kg² Recirculation 5 kg³ Extraction with metal ring 2
4
10
1
Detail Y 34,7239
Use of stone cladding20 mm thick wall panels (granite, marble)are possible.
20
Telescopic casing extracted airAvailable in 3 basic heights A:460-660 mm (standard)660-875 mm (medium)875-1305 mm (long)
Telescopic casing recirculation airAvailable in 4 basic heights A:565-650 mm: 2.5 kg activated charcoal (standard)650-780 mm: 5 kg activated charcoal (standard)780-995 mm: 5 kg activated charcoal (medium)995-1425 mm: 5 kg activated charcoal (long)
Distance above hobMinimum distance BFor electric hob: 500 mmFor gas hob: 650 mm
DW-Mistral DW-M9 (991), DW-M12 (992)Operatingmode
Extraction/recirculation
Mains connec-tion
220-240 V~ 50/60 Hz, 640 W Illumination 4 × 20 W, 12 V~ Fan speeds 4
Noise level 40-59 dB(A) Fuse 10 A Motor 1 × 260 W Weight ~42/48 kgOptions connection Max. 300 W
21516
450
154
~700
ø 150
440
~420
67
900/1200
550
BA
304260
140
71
For recirculation
air, see detail Y
for air outlet
0 200 400 600 800
400
300
200
100
0
40
30
20
10
0
1
23
4p
stat [
mm
WS
/CE
]
pst
at [
Pa]
Flow volume [m³/h]
Intensive
Use of stone cladding20 mm thick wall panels (granite,marble) are possible.
20
Telescopic casing extracted airAvailable in 2 basic heights A:500-820 mm (standard)820-1150 mm (long)
Telescopic casing recirculationairAvailable in 2 basic heights A:600-820 mm (standard)820-1150 mm (long)
Distance above hobMinimum distance BFor electric hob: 600 mmFor gas hob: 750 mm
25
10
0
Detail Y
166
12
V-ZUG Ltd Planning aid J001.059-12Industriestrasse 66, P.O. Box 59, 6301 ZugTel. +41 58 767 67 67, Fax +41 58 767 61 61
Kitchen appliances03.09.14
[email protected], www.vzug.com
73
DW-B9 (993), DW-B12 (62008)Operatingmode
Extraction/recirculation
Mains connec-tion
220-240 V~ 50/60 Hz, 640 W Illumination 4 × 20 W, 12 V~ Fan speeds 4
Noise level 40-59 dB(A) Fuse 10 A Motor 1 × 260 W Weight ~36 kgOptions connection Max. 300 W
147ø 150
44
0
900/1200 550
BA
3042602151
64
50~
70
0
140
71
67
For recirculation air,
see detail Y
for air outlet
0 200 400 600 800
400
300
200
100
0
40
30
20
10
0
1
23
4
pst
at [
mm
WS
/CE
]
pst
at [
Pa]
Flow volume [m³/h]
Intensive
Use of stone cladding20 mm thick wall panels (granite,marble) are possible.
20
Telescopic casing extracted airAvailable in 2 basic heights A:500-820 mm (standard)820-1150 mm (long)
Telescopic casing recirculationairAvailable in 2 basic heights A:600-820 mm (standard)820-1150 mm (long)
Distance above hobMinimum distance BFor electric hob: 600 mmFor gas hob: 750 mm
25
10
0
Detail Y
166
DW-B14 (994)Operatingmode
Extraction/recirculation
Mains connec-tion
220-240 V~ 50/60 Hz, 680 W Illumination 6 × 20 W, 12 V~ Fan speeds 4
Noise level 40-59 dB(A) Fuse 10 A Motor 1 × 260 W Weight ~45 kgOptions connection Max. 300 W
154ø 150
453
1400 550
BA
3042602151
6461~
713
140
80
53
800
For recirculation air,
see detail Y for
air outlet
0 200 400 600 800
400
300
200
100
0
40
30
20
10
0
1
23
4
pst
at [
mm
WS
/CE
]
pst
at [
Pa]
Flow volume [m³/h]
Intensive
Use of stone cladding20 mm thick wall panels (granite,marble) are possible.
20
Telescopic casing extracted airAvailable in 2 basic heights A:513-833 mm (standard)833-1163 mm (long)
Telescopic casing recirculationairAvailable in 2 basic heights A:613-833 mm (standard)833-1163 mm (long)
Distance above hobMinimum distance BFor electric hob: 600 mmFor gas hob: 750 mm
25
10
0
Detail Y
166
12
V-ZUG Ltd Planning aid J001.059-12Industriestrasse 66, P.O. Box 59, 6301 ZugTel. +41 58 767 67 67, Fax +41 58 767 61 61
Kitchen appliances03.09.14
[email protected], www.vzug.com
74
DW-SE9 (059)Operatingmode
Extraction/recirculation
Mains connec-tion
220-240 V~ 50/60 Hz, 415 W Illumination 2 × 20 W, 12 V~ Fan speeds 4
Noise level 44-64 dB(A) Fuse 10 A Motor 1 × 175 W Weight ~14 kgOptions connection Max. 200 W
477898
240250
AB
60
30
30
1 230~5
76
170
ø 15082
31
6 ¹
45
8
For recirculationair, see deatail Yfor air outlet
* With metal ring: 356 mm
0 100 200 300 400 500 6000
100
200
300
400
500
2
10
10
20
30
40
50
pst
at [
mm
WS
/CE
]
pst
at [
Pa
]
4
3
Flow volume [m³/h]
Intensive
Use of stone cladding20 mm thick wall panels (granite,marble) are possible.
20
Telescopic casing extracted airAvailable in 2 basic heights A:615-825 mm (standard)615-1125 mm (long)
Telescopic casing recirculationairAvailable in 2 basic heights A:700-825 mm (standard)700-1145 mm (long)
Distance above hobMinimum distance BFor electric hob: 600 mmFor gas hob: 750 mm 3
6.5
77
Detail Y 24142
DW-SE12 (068)Operatingmode
Extraction/recirculation
Mains connec-tion
220-240 V~ 50/60 Hz, 435 W Illumination 3 × 20 W, 12 V~ Fan speeds 4
Noise level 44-64 dB(A) Fuse 10 A Motor 1 × 175 W Weight ~20 kgOptions connection Max. 200 W
4771198
240250
AB
60
30
1
230~5
76
170
ø 150
45
8
82
31
6 ¹
30
For recirculationair, see deatail Yfor air outlet
* With metal ring: 356 mm
0 100 200 300 400 500 6000
100
200
300
400
500
2
10
10
20
30
40
50
pst
at [
mm
WS
/CE
]
pst
at [
Pa
]
4
3
Flow volume [m³/h]
Intensive
Use of stone cladding20 mm thick wall panels (granite,marble) are possible.
20
Telescopic casing extracted airAvailable in 2 basic heights A:615-825 mm (standard)615-1125 mm (long)
Telescopic casing recirculationairAvailable in 2 basic heights A:700-825 mm (standard)700-1145 mm (long)
Distance above hobMinimum distance BFor electric hob: 600 mmFor gas hob: 750 mm 3
6.5
77
Detail Y 24142
12
V-ZUG Ltd Planning aid J001.059-12Industriestrasse 66, P.O. Box 59, 6301 ZugTel. +41 58 767 67 67, Fax +41 58 767 61 61
Kitchen appliances03.09.14
[email protected], www.vzug.com
75
DW-Levante DW-L9 (990)Operatingmode
Extraction/recirculation
Mains connec-tion
220-240 V~ 50/60 Hz, 290 W Illumination 2 × 20 W, 12 V~ Fan speeds 4
Noise level 41-64 dB(A) Fuse 10 A Motor 1 × 250 W Weight ~34 kg
For recirculation air, see detail Y for air outlet
170
30
160
240250
ø 150
765
¹
62
6900
AB
724
.7~102
5
290
750
352309
80
* With metal ring: 805 mm
0 200 400 600 800
400
300
200
100
0
40
500 50
30
20
10
0
1
3
4
pst
at [
mm
WS
/CE
]
pst
at [
Pa
]
2
Flow volume [m³/h]
Intensive
Use of stone cladding20 mm thick wall panels (granite,marble) are possible.
20
Telescopic casing extracted airAvailable in 2 basic heights A:1280-1490 mm (standard)1280-1790 mm (long)
Telescopic casing recirculationairAvailable in 2 basic heights A:1365-1490 mm (standard)1365-1810 mm (long) Standard version recirculation air:without telescopic casing
Distance above hobMinimum distance BFor electric hob: 300 mmFor gas hob: 400 mm 3
6.5
77
Detail Y 24142
DW-Forano DW-F8 (042)Operatingmode
Extraction/recirculation
Mains connec-tion
220-240 V~ 50/60 Hz, 290 W Illumination 2 × 20 W, 12 V~ Fan speeds 4
Noise level 51-66 dB(A) Fuse 10 A Motor 1 × 250 W Weight ~29 kg
285255
ø 150
17
AB
75
167248
423
46
5.5
49
~7
30
46
0
35
5 ¹
47
0
800
300–540273
For recirculation air, see detail Y for air outlets
¹ For air outlet to the back
0 200 400 600 800
400
300
200
100
0
40
500 50
30
20
10
0
1
3
4
pst
at [
mm
WS
/CE
]
pst
at [
Pa
]
2
Flow volume [m³/h]
Intensive
Use of stone cladding20 mm thick wall panels (granite,marble) are possible.
20
Telescopic casing extracted airAvailable in 2 basic heights A:740-970 mm (standard)970-1274 mm (long)
Telescopic casing recirculationairAvailable in 1 basic height A:1024-1374 mm (long)
Standard version recirculation air:without telescopic casing
Distance above hobMinimum distance B: 650 mm
12614.7
49
76
Detail Y
12
V-ZUG Ltd Planning aid J001.059-12Industriestrasse 66, P.O. Box 59, 6301 ZugTel. +41 58 767 67 67, Fax +41 58 767 61 61
Kitchen appliances03.09.14
[email protected], www.vzug.com
76
12.4 Built-in hoods
Applicable to the following hoods:• For activation of external motor flaps, roof ventilators, room fans, etc., see document P60.008.
• Connection cable 1.2 m with plug
Positions of electrical connections
The specified dimensions are valid for straight exhaust air piping. If exhaust air pipings with an elbow are used, the dimen-sions must be adapted accordingly.
Designation Connection from floor(plinth height 100 mm)
Connection in niche(from centre to connection)
Type of connection
All models 2050 mm 180 mm Flush power socket230 V
12
V-ZUG Ltd Planning aid J001.059-12Industriestrasse 66, P.O. Box 59, 6301 ZugTel. +41 58 767 67 67, Fax +41 58 767 61 61
Kitchen appliances03.09.14
[email protected], www.vzug.com
77
DF-Premira DFPQ12 (61013)Operatingmode
Extraction/recirculation
Mains connec-tion
220-240 V~ 50/60 Hz, 136.6 W Illumination 3 × 2.2 W Fan speeds 4
Noise level 40-67 dB(A) Fuse 10 A Motor 1 × 130 W Weight ~27.5 kgOptions connection (optional) Max. 300 W
330-370
292
1200
300-345¹
55
¹
¹
290290
300-345
1198
6755
200
h
ø15030
495
55
BC
pst
at [
Pa
]
100
200
300
400
0
Flow volume [m³/h]200 400 6000
pst
at [
mm
WS
/CE
]
10
20
30
40
0
3
2
1
4 Intensive
Use of stone cladding20 mm thick wall panels(granite, marble) arepossible.
20
h: Extraction/recirculation 2.5 kg: 452 mm, extraction with metal ring: 477 mm, Recirculation 5 kg: 600 mm
Distance above hobMinimum distance BFor electric hob: 500 mmFor gas hob: 650 mm
¹ For wall unit depth of 351-370 mm: additional finished profile required
Finished profile included in scope of delivery: Available as option:Type Width Wall unit depth Article no. Type Width Wall unit depth Article no. DFPQ12 1198 mm 330-350 mm H42660 DFPQ12 1198 mm 351-370 mm H42803
Front coverAvailable as option
Recirculation air set for wall unit without panelAvailable as option, can be combined with H42614 andH42615
Type Material Height C Article no. Type Material Article no. DFPQ12 ChromeClass 410-790 mm H42614 DFPQ12 ChromeClass H42630 DFPQ12 ChromeClass 791-1150 mm H42615
CC
292
300
292
330299
A
For changing the filter, the front cover A must be removable.
12
V-ZUG Ltd Planning aid J001.059-12Industriestrasse 66, P.O. Box 59, 6301 ZugTel. +41 58 767 67 67, Fax +41 58 767 61 61
Kitchen appliances03.09.14
[email protected], www.vzug.com
78
DF-Premira DFPQ6 (61015), DFPQ9 (61014)Operatingmode
Extraction/recirculation
Mains connec-tion
220-240 V~ 50/60 Hz, 134,4 W Illumination 2 × 2,2 W Fan speeds 4
Noise level 40-67 dB(A) Fuse 10 A Motor 1 × 130 W Weight ~19.5/23.5 kg
330-350
292
600/900
300-325
55290290
300-325
598/898
67
55
200
452¹/600²
ø15030
495
BC
¹ Extraction/recirculation 2.5 kg² Recirculation 5 kg
pst
at [
Pa
]
100
200
300
400
0
Flow volume [m³/h]200 400 6000
pst
at [
mm
WS
/CE
]
10
20
30
40
0
3
2
1
4 Intensive
Use of stone cladding20 mm thick wall panels(granite, marble) arepossible.
20
Distance above hobMinimum distance B:For electric hob: 500 mmFor gas hob: 650 mm
Front coverAvailable as option
Recirculation air set for wall unit without panelAvailable as option
Type Material Height C Article no. Type Material Article no.DFPQ6, DFPQ9 ChromeClass 410-790 mm H42614 DFPQ6, DFPQ9 ChromeClass H42630DFPQ6, DFPQ9 ChromeClass 791-1150 mm H42615
CC
292
300
292
330299
A
Can be combined with front cover H4.2614 and H4.2615
12
V-ZUG Ltd Planning aid J001.059-12Industriestrasse 66, P.O. Box 59, 6301 ZugTel. +41 58 767 67 67, Fax +41 58 767 61 61
Kitchen appliances03.09.14
[email protected], www.vzug.com
79
DF-Premira SL DFPQSL6 (61008), DFPQSL9 (61007)Operatingmode
Extraction/recirculation
Mains connec-tion
220-240 V~ 50/60 Hz, 134.4 W Illumination 2 × 2.2 W Fan speeds 4
Noise level 40-67 dB(A) Fuse 10 A Motor 1 × 130 W Weight ~12.5/16.5 kgOptions connection (optional) Max. 300 W
330-370 ¹
292
550/600/900
300-345 ¹
290290
300-345 ¹
548/598/898
76
200ø1503
0
480
25
78
h
B
C
pst
at [
Pa
]
100
200
300
400
0
Flow volume [m³/h]200 400 6000
pst
at [
mm
WS
/CE
]
10
20
30
40
0
2
1
4
3
Intensive
Use of stone cladding20 mm thick wall panels(granite, marble) arepossible.
20
h: Extraction/recirculation 2.5 kg: 452 mm, extraction with metal ring: 490 mm, Recirculation 5 kg: 600 mm
Distance above hobMinimum distance BFor electric hob: 500 mmFor gas hob: 650 mm
¹ For wall unit depth of 351-370 mm: additional finished profile required
Finished profile included in scope of delivery: Available as option:Type Width Wall unit depth Type Width Wall unit depth Article no.DFPQSL6 598 mm 330-350 mm DFPQSL6 598 mm 351-370 mm H42805DFPQSL9 898 mm 330-350 mm DFPQSL9 898 mm 351-370 mm H42806
Front coverAvailable as option
Recirculation air set for wall unit without panelavailable as option, can be combined with H42614 and H42615
Type Material Height C Article no. Type Material Article no. DFPQSL6/9 ChromeClass 410-790 mm H42614 DFPQSL5/6/9 ChromeClass H42630 DFPQSL6/9 ChromeClass 791-1150 mm H42615
CC
292
300
292
A
330299
For changing the filter, the front cover A must be remov-able.
12
V-ZUG Ltd Planning aid J001.059-12Industriestrasse 66, P.O. Box 59, 6301 ZugTel. +41 58 767 67 67, Fax +41 58 767 61 61
Kitchen appliances03.09.14
[email protected], www.vzug.com
80
Concave deflector plate DF-SLG9 (385)Operatingmode
Extraction/recirculation
Mains connec-tion
220-240 V~ 50/60 Hz, 260 W Illumination 2 × 20 W, 12 V~ Fan speeds 4
Noise level 47-65 dB(A) Fuse 10 A Motor 2 × 110 W Weight ~17 kg
13
0 ¹
35
7
16
73
B
900
552
192
≥ 200
≤ 525
280–350
896
14–175
21
0
ø 120ø 150
Wall unit depth 280-350mm²
898 Base
898 Finished profile
Reduction connection
¹ With metal ring: 170 mm² Recirculation version only possible with wall unit depth of 280-330 mm
1
4
400
300
200
100
0
40
30
20
10
00 100 200 300 400 500 600 700
pst
at [
mm
WS
/CE
]
pst
at [
Pa
]
3
2
Flow volume [m³/h]
Use of stone cladding20 mm thick wall panels(granite, marble) arepossible.
20
Distance above hobMinimum distance B:For electric hob: 600 mmFor gas hob: 750 mm
Finished profilesincluded in scope of delivery:
70 75
896
Available as option:
70 37.5
896
Type Profilesection
Width Wall unit depth Article no. Type Profilesection
Width Wall unit depth Articleno.
DF-SLG9 Wide 896 mm 320-350 mm H41759 DF-SLG9 Narrow 896 mm 280–315 mm H41758
12
V-ZUG Ltd Planning aid J001.059-12Industriestrasse 66, P.O. Box 59, 6301 ZugTel. +41 58 767 67 67, Fax +41 58 767 61 61
Kitchen appliances03.09.14
[email protected], www.vzug.com
81
Concave deflector plate DF-SLG6 (384)Operatingmode
Extraction/recirculation
Mains connec-tion
220-240 V~ 50/60 Hz, 260 W Illumination 2 × 20 W, 12 V~ Fan speeds 4
Noise level 47-65 dB(A) Fuse 10 A Motor 2 × 110 W Weight ~15 kg
≥ 200
192
130 ¹
357
16
≤ 525
280–350
73
600
595
552
14–175
210
B
ø 120ø 150
280-350mm ²
598Base
596
598
596
Reduction connection
Finished profile
Wall unit depth
¹ With metal ring: 170 mm² Recirculation version only possible with wall unit depth of 280-330 mm
1
4
400
300
200
100
0
40
30
20
10
00 100 200 300 400 500 600 700
pst
at [
mm
WS
/CE
]
pst
at [
Pa
]
3
2
Flow volume [m³/h]
Use of stone cladding20 mm thick wall panels(granite, marble) are possible.
20
Distance above hobMinimum distance B:For electric hob: 600 mmFor gas hob: 750 mm
Finished profilesincluded in scope of delivery:
70 75
896
Available as option:
70 37.5
896
Type Profilesection
Width Wall unit depth Article no. Type Profilesection
Width Wall unit depth Article no.
DF-SLG6 Wide 596 mm 320-350 mm H41755 DF-SLG6 Narrow 596 mm 280-315 mm H41754
12
V-ZUG Ltd Planning aid J001.059-12Industriestrasse 66, P.O. Box 59, 6301 ZugTel. +41 58 767 67 67, Fax +41 58 767 61 61
Kitchen appliances03.09.14
[email protected], www.vzug.com
82
Flat deflector plate DF-SG6 (360)Operatingmode
Extraction/recirculation
Mains connec-tion
220-240 V~ 50/60 Hz, 316 W Illumination 2 × 28 W, 230 V~ Fan speeds 3
Noise level 45-63 dB(A) Fuse 10 A Motor 2 × 130 W Weight ~14 kg
13
0 ¹
35
7
B
552
≤ 525
280–350
596
≤ 155
32
21
0
≥ 200
600
192
ø 120ø 150
30
16 598
Finished profile
Reductionconnection
Wall unit depth 280-350mm ²
¹ With metal ring: 170 mm² Recirculation version only possible with wall unit depth of 280-330 mm
1
2
3
pst
at [
mm
WS
/CE
]
pst
at [
Pa]
500
400
300
200
100
0 100 200 300 400 500
40
30
20
10
50
0600
0
Flow volume [m³/h]
Use of stone cladding20 mm thick wall panels(granite, marble) arepossible.
20
Distance above hobMinimum distance B:For electric hob: 600 mmFor gas hob: 750 mm
Finished profilesincluded in scope of delivery:
Wide75
596
26
Type Profilesection
Width Wall unit depth Article no. ChromeClass
DF-SG6 Wide 596 mm 321-350 mm H42281
Available as option: Narrow
26 24
596
Medium
596
44
26
Type Profilesection
Width Wall unit depth Article no. ChromeClass
DF-SG6 Narrow 596 mm 280-300 mm H42225 DF-SG6 Medium 596 mm 290-320 mm H42226
12
V-ZUG Ltd Planning aid J001.059-12Industriestrasse 66, P.O. Box 59, 6301 ZugTel. +41 58 767 67 67, Fax +41 58 767 61 61
Kitchen appliances03.09.14
[email protected], www.vzug.com
83
Flat deflector plate DF-SG9 (549)Operatingmode
Extraction/recirculation
Mains connec-tion
220-240 V~ 50/60 Hz, 316 W Illumination 2 × 28 W, 230 V~ Fan speeds 3
Noise level 45-63 dB(A) Fuse 10 A Motor 2 × 130 W Weight ~16 kg
130 ¹
210
357
30
16
B
552
321–350
895
≤ 155
32
≤ 525
900
≥ 200
192
ø 120ø 150
321-350mm ²
898
896
Reduction connection
Finished profile
Base
Wall unit depth
¹ With metal ring: 170 mm² Recirculation version only possible with wall unit depth of 321-330 mm
1
2
3
pst
at [
mm
WS
/CE
]
pst
at [
Pa
]
500
400
300
200
100
0 100 200 300 400 500
40
30
20
10
50
0600
0
Flow volume [m³/h]
Use of stone cladding20 mm thick wall panels(granite, marble) are possible.
20
Distance above hobMinimum distance B:For electric hob: 600 mmFor gas hob: 750 mm
Finished profileincluded in scope of delivery:
70 75
896
Type Profilesection
Width Wall unit depth Article no. ChromeClass
DF-SG9 Wide 896 mm 321-350 mm H42294
12
V-ZUG Ltd Planning aid J001.059-12Industriestrasse 66, P.O. Box 59, 6301 ZugTel. +41 58 767 67 67, Fax +41 58 767 61 61
Kitchen appliances03.09.14
[email protected], www.vzug.com
84
DHL8 (64001), DHL11 (64002)Operatingmode
Extraction/recirculation
Mains connec-tion
220-240 V~ 50/60 Hz, 200 W Illumination 4 × 3 W Fan speeds 4
Noise level 40-61 dB(A) Fuse 10 A Motor 188 W Weight ~22.5/30.5 kg
300
35
5
800/1100
300
275 163.5 ø150
350
24
X
Y
500
400
300
200
100
00 100 200 300 400 500 600
0
10
20
30
40
50
Flow volume [m³/h]
pst
at [
Pa
]
pst
at [
mm
WS
/CE
]4 Intensive
3
2
1
View Y
205
The range hood can be converted so that the exhaustair connection is at the back of the appliance. Distance above hobMinimum distance BFor electric hob: 500 mmFor gas hob: 750 mm
Cut-out for wall unit (view X)
791¹/1091¹
807–885/1107–1185
28
3¹
≥
30
≥
35
0
¹ Cut-out measurements Use of stone cladding
20 mm thick wall panels (granite,marble) are possible.
20
12
V-ZUG Ltd Planning aid J001.059-12Industriestrasse 66, P.O. Box 59, 6301 ZugTel. +41 58 767 67 67, Fax +41 58 767 61 61
Kitchen appliances03.09.14
[email protected], www.vzug.com
85
12.5 Air recycling cassette (LRC)
• Installation in ceiling cover strip
Operating mode Suitable for all built-in range hoods (exception: DF-U!)Replacement activated charcoal filter H40770Pipe connector supplied 1 × ø 125 mmWeight ~6 kg
13
0
530
283
515
≥ 1
0
330
≥ 290
512
133
17–24
11
4
11
2
= =
ø 125
75
20°
12.6 Air outlet cassette (LAC)
• Installation in ceiling cover strip
Operating mode Suitable for all built-in range hoods (exception: DF-U!)Pipe connector supplied 1 × ø 125 mmReduction connections supplied for rangehoods
ø 150 to ø 125 mm
Weight ~5 kg
13
0
530
283
515
≥ 1
0
330
≥ 290
512
133
17–24
11
4
11
2
= =
ø 125
75
20°
12
V-ZUG Ltd Planning aid J001.059-12Industriestrasse 66, P.O. Box 59, 6301 ZugTel. +41 58 767 67 67, Fax +41 58 767 61 61
Kitchen appliances03.09.14
[email protected], www.vzug.com
86
13 Refrigerators
13.1 General notes
Insufficient ventilation can cause a malfunction and shorten the life of the appliance.
Heavy door panel weights shorten the service life of the door hinges.
Efficient repairs can only be guaranteed if it is possible to uninstall the whole appliance at any time without causing anydamage.
In an open-plan kitchen and living room, a raised noise level can be expected if the ventilation slits face into the room.
13.2 Electrical connection data
Appliance Energy efficiencyclass
Mains connection Fuse Mains cable
RefrigeratorsCooltronic 60i SN-ST
230 V~ 50 Hz
10 A
2.2 m, with plug
Noblesse 60iPrestige P 60i eco SN-TFutura 60i
SN-STRoyal 60iDe Luxe 60iMagnum 60i eco SN-T 230 V~ 50 Hz 2.5 m, with plugKomfort 60i N-STWinecoolerWinecooler SL 60 SN-ST 230 V~ 50 Hz 10 A 2.1 m, with plug
13.3 Room temperature
Climate class Minimum MaximumSN +10 °C +32 °CN +16 °C +32 °CST +16 °C +38 °CT +16 °C +43 °C
13.4 Niche ventilation
Shadow gaps for air circulation – even if extending over the width of several units – are insufficient.
13
V-ZUG Ltd Planning aid J001.059-12Industriestrasse 66, P.O. Box 59, 6301 ZugTel. +41 58 767 67 67, Fax +41 58 767 61 61
Kitchen appliances03.09.14
[email protected], www.vzug.com
87
13.5 Refrigerators
Cooltronic 60i (51029) Noblesse 60i (51028)KC 60i (integrable in niche height 1778 mm)Maximum permissible weight of door panel is 17.5 kg
KN 60i (integrable)Maximum permissible weight of door panel: 17.5 kg
1270+
a-b/2
508+
a-b/2
a
≤ 594 545
54816–20
560–568
17781776
+2 0
a
≥ 550
≥ 200 cm²
≥ 200 cm²
≥ 50
1270+
a-b/2
508+
a-b/2
a
≤ 594 545
54816–20
560–568
1778
1776
+2 0
a
≥ 550
≥ 200 cm²
≥ 200 cm²
≥ 50
Prestige P 60i eco (51027, 51052) Magnum 60i eco (51031)KRRP 60i eco (integrable in niche height 1778 mm)Maximum permissible weight of door panel is 17.5 kg
KM 60i eco (integrable)Maximum permissible weight of door panel is 25 kg
1143+
a-b/2
635+
a-b/2
a
≤ 594 545
54816–20
560–568
1778
1776
+2 0
a
≥ 550
≥ 200 cm²
≥ 200 cm²
≥ 50
1778+
2 0
≥ 550
≥ 200 cm²
≥ 200 cm²
≥ 50
1778+
a
1770
54816–20
≤ 594 545
560–568
a Niche overlapb Gap (≥ 4 mm)
13
V-ZUG Ltd Planning aid J001.059-12Industriestrasse 66, P.O. Box 59, 6301 ZugTel. +41 58 767 67 67, Fax +41 58 767 61 61
Kitchen appliances03.09.14
[email protected], www.vzug.com
88
Futura 60i (51020) Royal 60i (51018)KF 60i (integrable in niche height 1524 mm)Maximum permissible weight of door panel is 17.5 kg
KR 60i (integrable)Maximum permissible weight of door panel: 17.5 kg
889+
a-b/2
635+
a-b/2
a
≤ 594 545
54816–20
560–56815241522
+2 0
a
≥ 550
≥ 200 cm²
≥ 200 cm²
≥ 50
560–568
≥ 550
≥ 200 cm²
≥ 200 cm²
≥ 50
1522
1524+
a
54816–20
≤ 594 545
1524+2 0
De Luxe 60i (51017) Komfort 60i (51048)KL 60i (integrable in niche height 1524 mm)Maximum permissible weight of door panel is 17.5 kg
KK 60i (integrable)Maximum permissible weight of door panel is 17.5 kg
560–568
≥ 550
≥ 200 cm²
≥ 200 cm²
≥ 50
1522
1524+
a
54816–20
≤ 594 545
1524+2 0
17
≥ 550
100–185
545
16–20
100–185
600
597
≥ 680
30–60
≥ 600
595
819–869
(≤ 889)
820–870
(≤ 890)
3A
Ventilation partintegrated in plinth
Plinth must be recessed for ventilation purposes
Detail A
a Niche overlapb Gap (≥ 4 mm)
Installation kit for stone cladding is enclosed: H72998
13
V-ZUG Ltd Planning aid J001.059-12Industriestrasse 66, P.O. Box 59, 6301 ZugTel. +41 58 767 67 67, Fax +41 58 767 61 61
Kitchen appliances03.09.14
[email protected], www.vzug.com
89
13.6 Winecoolers
Winecooler SL (629)KW-SL/60
594 566
873
547
886
≥ 200 cm²
560–568
≥ 550
≥ 200 cm²
≥ 50
H
874–889
X
Y
Detail X
U ²
H1
Detail Y
H U ¹
1
Niche height
HInstallation kit
Art. no.Installation kit
HeightOverlap
U1 U2
874-877 - - 6 mm 3-6 mm877-880 H72435 3 mm 3 mm 3-6 mm
13
V-ZUG Ltd Planning aid J001.059-12Industriestrasse 66, P.O. Box 59, 6301 ZugTel. +41 58 767 67 67, Fax +41 58 767 61 61
Kitchen appliances03.09.14
[email protected], www.vzug.com
90
14 DishwashersDishwashers with heat pump [➙ see page 100]
14.1 General notes
Efficient repairs can only be guaranteed if it is possible to uninstall the whole appliance at any time without causing anydamage.
At any time it must be possible to pull the appliance out of the niche horizontally without dismantling any part of the cabinet.
For work surfaces that are susceptible to moisture, use work surface protection W70163.
General operating conditionsAmbient temperature: min. 10 °C to max. 35 °C
The appliances are designed for use up to a max. altitude of 2000 m above sea level.
14.2 Electrical connection data / plumbing in
40
12
0
K
L M
N
G1
G2
D
C B
A
Designation Connection from floor
(plinth height 105 mm)Connection in niche (from
centre to connection)Type of connection
A Electrical connection 600 mm K = 160 mm Flush power socket 230 VB Cold water 600 mm N = 170 mm G¾"C Hot water * 600 mm M = 70 mm G¾"D Drain 400 mm L = 110 mm ø 56 mmG1 Dishwasher in base unit Connection in adjacent compartment left and rightG2 Dishwasher in tall unit Connection in max. 2 compartments left and right
* Water connection at >60 °C is not recommended
14
V-ZUG Ltd Planning aid J001.059-12Industriestrasse 66, P.O. Box 59, 6301 ZugTel. +41 58 767 67 67, Fax +41 58 767 61 61
Kitchen appliances03.09.14
[email protected], www.vzug.com
91
Electrical connection data
Appliance Country group*
Mains connection Rated load Fuse Mains cable
Adora SL (41005-41008, 41042, 41043) A, C, E 230 V~ 50 Hz 3300 W 16 A
1.5 m, withplug
B 2200 W 10 AD 220-240 V~ 50 HzF 3300 W 16 A
Adora S (41010, 41016, 41034-41037) A, B, C, D, E, F 230 V~ 50 Hz 2200 W 10 AAdora N (41011, 41029, 41030-41033)
* Key [➙ see page 2]
Plumbing-in data
For special cases with water hardness in excess of 50 °fH, an external water softener is recommended.
Value Nominal value Minimum MaximumMains pressure (0.1 MPa = 1 bar) Static 0.3–0.4 MPa 0.1 MPa 1.0 MPa
Flowing – 0.08 MPa 1.0 MPaWater hardness – 0.5 °fH 50 °fHWater inlet temperature Cold water – 5 °C 35 °C
Hot water – 40 °C 60 °C
If the water pressure is too high, a pressure reducer valve must be fitted.
Connection example
A1
F
E, C
E, B
D
A2
Designation Adora dishwasherA1 Power socket YesA2 Connection cable Length 1.50 mB Cold water connection YesC Hot water connection YesD Drain hose Length 1.55 m
Internal diameter = 22 mmE Shut-off devices YesF Aqua-stop / water inlet with filter, G¾" Length 1.55 m
14
V-ZUG Ltd Planning aid J001.059-12Industriestrasse 66, P.O. Box 59, 6301 ZugTel. +41 58 767 67 67, Fax +41 58 767 61 61
Kitchen appliances03.09.14
[email protected], www.vzug.com
92
14.3 Installation summary
Depending on niche height H, either standard or extra height appliances or only one of the two can be installed.
790 800 810 820 830 840 851 860 870 880 890 900 910 920 930 940 950 960
220230240250
S G
210 S S G G
200 S S S G G G
190 S S S S G G G
180 S S S S S G G G
170 S S S S S S
SSSSSS
SSSSSS
SSSSSS
G G G
160 S S S S S S S/G G G G
150 S S S S S S S/G G G G
140 S S S S S S S/G S/G G G G
130 S S S S S S S/G S/G G G G G
120 S S S S S S S/G S/G G G G G G
110 S S S S S S S/G S/G
S/GS/GS/GS/GS/GS/G
S/GS/GS/GS/GS/GS/G
S/GS/GS/GS/GS/GS/G
G G G G G G
107 S S S S S S S/G G G G G G
100 S S S S S S S/G S/G G G G G G G
G
G
G
G
G
G
G
G
G
G
G
G
G
G
G
G
G
G
G
G
G
G
G
G
G
G
G
G
G
G
G
G
G
G
G
G
90 S S S S S S S/G G G G G G G
80 S S S S S S G G G G G G
70 S S S S S G G G G G
60 S S S S G G G G
50 S S S G G G
40 S S G G
30 S G
23 G
S
G
S/G
S/GS/GS/GS/GS/GS/G S/GD
ime
nsio
n A
in
mm
Standard
Extra height
Standard and extra height
Niche height H in mm
H
A
14
V-ZUG Ltd Planning aid J001.059-12Industriestrasse 66, P.O. Box 59, 6301 ZugTel. +41 58 767 67 67, Fax +41 58 767 61 61
Kitchen appliances03.09.14
[email protected], www.vzug.com
93
14.4 Drilling plans for decor panel 60 cm
61
37
16
9
169
169
576576576
576
582
4 × ø 2.0Depth 12 from rear
8 × ø 2.0Depth 12 from rear
4 × ø 2.0
Integrated Fully integrated Two-part
Depth 12 from rear
(Extr
a h
eig
ht 415)
350
(Extr
a h
eig
ht 415)
(Extr
a h
eig
ht 415)
350
350
14
V-ZUG Ltd Planning aid J001.059-12Industriestrasse 66, P.O. Box 59, 6301 ZugTel. +41 58 767 67 67, Fax +41 58 767 61 61
Kitchen appliances03.09.14
[email protected], www.vzug.com
94
14.5 Adora SL, S, N with niche width 60 cm
It must be ensured air gap remains in the shadow gap.
Screws and fasteners must be countersunk in the niche. There should be no protruding parts, screw heads, brackets, etc.,otherwise parts of the appliance could become damaged (risk of water damage).
The permissible weights of the front panel / decor system 1 depend on the design variant:
IntegratedNero, white
IntegratedChromeClass
Design integratedMirror glass
Fully integrated
Maximum weight 8 kg 7 kg 6.5 kg 7 kgMinimum weight 5.5 kg 4.5 kg 4 kg 5 kg
• Front panel / decor system (wood) 1 fully integrated must be cut to the necessary dimensions.
For stronger springs, see Accessories Dishwashers [➙ see page 122]
Compensator for ChromeClass and mirror glassCompensator set: See Accessories [➙ see page 106]If the bottom edge of the operating panel Bis not at the same height X as the bottomedge of the adjacent kitchen drawer C, alevelling piece (compensator K) must bemounted (see Installation instructionsJ182.51).
X
B C
K
Compensators contained in the set:8 mm, 12 mm, 16 mm
14
V-ZUG Ltd Planning aid J001.059-12Industriestrasse 66, P.O. Box 59, 6301 ZugTel. +41 58 767 67 67, Fax +41 58 767 61 61
Kitchen appliances03.09.14
[email protected], www.vzug.com
95
Base unit «standard»
786–867 *
*
21–226
780–861 *
30–100
639–757
1
596 572
585
600
16–22
≥ 580BD
* Up to max. 896 with a second runner only,can be ordered under W82930 ** Up to max. 902 with a second runner only,can be ordered under W82930
Nero, white ChromeClass Mirror glassOperating panel Bincl. compensator
124-146 mm 124-140 mm 124-140 mm
Decor panel D 490-632 mm 496-632 mm 496-632 mm
Size of base gap S.
790 800 810 820 830 840 850 860 870
107107 117
107 117 127117 127 137127 137 147137 147 155
47 57 67 778797
145 155 165
22222222510152330
37 47 57 67 778797
27 37 47 57 67 778797
Min.
Max.
127127 137
107117
127 137 147127 137 147
97107117
157127 137 147 157 167
127 137 147 157
87 97107117
167 177137 147 157 167 177 187147 157 167
77 87 97107117
177 187 197157 167 177 187 197 207167 177
67 77 87 97107117
187 197 207 217175 185 195 205 215 225
880
137147
117127
157167177187197207217227235
890
147157
127137
167177187197207217227237245
900
157167
137147
177187197207217227237247255
57 67 77 87 97107117
Niche height H in mm Min. Sin mm
Dim
ensio
n A
in m
m H30–100
A
S
14
V-ZUG Ltd Planning aid J001.059-12Industriestrasse 66, P.O. Box 59, 6301 ZugTel. +41 58 767 67 67, Fax +41 58 767 61 61
Kitchen appliances03.09.14
[email protected], www.vzug.com
96
Base unit «extra height»
851–932 *
*
21–226
845–926 *
30–100
704–822
1
596 572
650
600
16–22
≥ 580B
D
* Up to max. 961 with a second runner only,can be ordered under W82930 ** Up to max. 967 with a second runner only,can be ordered under W82930
Nero, white ChromeClass Mirror glassOperating panel Bincl. compensator
124-146 mm 124-140 mm 124-140 mm
Decor panel D 555-697 mm 561-697 mm 561-697 mm
Size of base gap S.
851 860 870 880 890 900 910 920 930
102102 112
103 112 122113 122 132123 132 142133 142 152
42 52 62 728292
141 150 160
22222222510152330
32 42 52 62 728292
23 33 43 53 63 738393
Min.
Max.
122122 132
102112
122 132 142122 132 142
92102112
152122 132 142 152 162
122 132 142 152
82 92102112
162 172132 142 152 162 172 182142 152 162
72 82 92102112
172 182 192152 162 172 182 192 202162 172
62 72 82 92102112
182 192 202 212170 180 190 200 210 220
940
132142
112122
152162172182192202212222230
950
142152
122132
162172182192202212222232240
960
152162
132142
172182192202212222232242250
52 62 72 82 92102112
Niche height H in mm Min. Sin mm
Dim
ensio
n A
in m
m H
30–100
A
S
14
V-ZUG Ltd Planning aid J001.059-12Industriestrasse 66, P.O. Box 59, 6301 ZugTel. +41 58 767 67 67, Fax +41 58 767 61 61
Kitchen appliances03.09.14
[email protected], www.vzug.com
97
Tall unit «standard»Can also be installed in base unit on base element
Tall unit «extra height»
D
756
757
764
+1
-2
105
596 572
600
501
585
B
3 m
m
C
C Slide plate
12
0
40
D
821
822
829
+1
-2
105
596 572
600
501
650
B
3 m
m
C
Nero, white ChromeClass Mirror glass Nero, white ChromeClass Mirror glassOperating panelB incl. compen-sator
124-146 mm 124-140 mm 124-140 mm Operating panelB incl. compen-sator
124-146 mm 124-140 mm 124-140 mm
Decor panel D 610-632 mm 616-632 mm 616-632 mm Decor panel D 675-697 mm 681-697 mm 681-697 mm
Slide plate for tall unit must be ordered from V-ZUG.
14
V-ZUG Ltd Planning aid J001.059-12Industriestrasse 66, P.O. Box 59, 6301 ZugTel. +41 58 767 67 67, Fax +41 58 767 61 61
Kitchen appliances03.09.14
[email protected], www.vzug.com
98
Tall unit «extra height» with decor panel and drawer 251 mm
Slide plate for tall unit must be ordered from V-ZUG.
596 572187
600
50
251
829
+1
-2
821
105
650
D
B
757
1
120
40
3 m
m
C
C Slide plateE Removable cover strip
Cross-section of installation variant
60
251
1,5
1016 (
8/6
)
40
D
105
E
Nero, white ChromeClass Mirror glassOperating panel Bincl. compensator
124-146 mm 124-140 mm 124-140 mm
Decor panel D 610-632 mm 616-632 mm 616-632 mm
Installing extra-long decor panel
≥ 100*
H
6
5
E
F
G
* A continuous underside strip is recommended. E WorktopF Continuous underside stripG Decor panelH Niche height
14
V-ZUG Ltd Planning aid J001.059-12Industriestrasse 66, P.O. Box 59, 6301 ZugTel. +41 58 767 67 67, Fax +41 58 767 61 61
Kitchen appliances03.09.14
[email protected], www.vzug.com
99
15 Dishwashers with heat pump
15.1 General notes
Efficient repairs can only be guaranteed if it is possible to uninstall the whole appliance at any time without causing anydamage.
At any time it must be possible to pull the appliance out of the niche horizontally without dismantling any part of the cabinet.
For work surfaces that are susceptible to moisture, use work surface protection W70163.
General operating conditionsAmbient temperature: min. 10 °C to max. 35 °C
The appliances are designed for use up to a max. altitude of 2000 m above sea level.
15.2 Electrical connection data / plumbing in
40
12
0
K
L M
N
G1
G2
D
C B
A
Designation Connection from floor(plinth height 105 mm)
Connection in niche (fromcentre to connection)
Type of connection
A Electrical connection 600 mm K = 160 mm Flush power socket 230 VB Cold water 600 mm N = 170 mm G¾"C Hot water * 600 mm M = 70 mm G¾"D Drain 400 mm L = 110 mm ø 56 mmG1 Dishwasher in base unit Connection in adjacent compartment left and rightG2 Dishwasher in tall unit Connection in max. 2 compartments left and right
* Water connection at >60 °C is not recommended
15
V-ZUG Ltd Planning aid J001.059-12Industriestrasse 66, P.O. Box 59, 6301 ZugTel. +41 58 767 67 67, Fax +41 58 767 61 61
Kitchen appliances03.09.14
[email protected], www.vzug.com
100
Electrical connection data
Appliance Country group * Mains connection Rated load Fuse Mains cableAdora SL WP (41009,41038)
A, C, E 230 V~ 50 Hz 3300 W 16 A 1.5 m, with plugB 2200 W 10 A
D 220-240 V~ 50 HzF 3300 W 16 A
* Key [➙ see page 2]
Plumbing-in data
For special cases with water hardness in excess of 50 °fH, an external water softener is recommended.
Value Nominal value Minimum MaximumMains pressure (0.1 MPa = 1 bar) Static 0.3–0.4 MPa 0.1 MPa 1.0 MPa
Flowing – 0.08 MPa 1.0 MPaWater hardness – 0.5 °fH 50 °fHWater inlet temperature – 5 °C 60 °C
Connection example
A1
F
E, C
E, B
D
A2
Designation Adora dishwasherA1 Power socket YesA2 Connection cable Length 1.50 mB Cold water connection YesC Hot water connection YesD Drain hose Length 1.55 m
Internal diameter = 22 mmE Shut-off devices Yes, ¾"F Aqua-stop / water inlet with filter, G¾" Length 1.55 m
15
V-ZUG Ltd Planning aid J001.059-12Industriestrasse 66, P.O. Box 59, 6301 ZugTel. +41 58 767 67 67, Fax +41 58 767 61 61
Kitchen appliances03.09.14
[email protected], www.vzug.com
101
15.3 Installation summary
Keep base compartment unobstructed, appliance stands on the floor.
Size of base gap S.
870 880 890 900 910
200190180170160150140130120110105
S
SSSSSS
SSSSSS
SSSSSS
SSSSSS
SSSSSS
S
Standard without cabinet plinth
H
A
Niche height H in mm
Dim
en
sio
n A
in
mm
15.4 Drilling plans for decor panel 60 cm
61
37
169
169
169
576576576
576
582
4 × ø 2.0 8 × ø 2.0
4 × ø 2.0
350
350
350
Depth 12 from rear Depth 12 from rear Depth 12 from rear
Integrated Fully integrated Two-part
15
V-ZUG Ltd Planning aid J001.059-12Industriestrasse 66, P.O. Box 59, 6301 ZugTel. +41 58 767 67 67, Fax +41 58 767 61 61
Kitchen appliances03.09.14
[email protected], www.vzug.com
102
15.5 Adora SL WP with niche width 60 cm
It must be ensured air gap remains in the shadow gap.
Screws and fasteners must be countersunk in the niche. There should be no protruding parts, screw heads, brackets, etc.,otherwise parts of the appliance could become damaged (risk of water damage).
At any time it must be possible to pull the appliance out of the niche horizontally without dismantling any part of the cabinet.
The permissible weights of the front panel / decor system 1 depend on the design variant:
IntegratedNero, white
IntegratedChromeClass
Design integratedMirror glass
Fully integrated
Maximum weight 8 kg 7 kg 6.5 kg 7 kgMinimum weight 5.5 kg 4.5 kg 4 kg 5 kg
• Front panel / decor system (wood) 1 fully integrated must be cut to the necessary dimensions.
For stronger springs, see Accessories Dishwashers [➙ see page 122]
Compensator for ChromeClass and mirror glassCompensator set: see Accessories Dishwashers [➙ see page 122]If the bottom edge of the operating panel Bis not at the same height X as the bottomedge of the adjacent kitchen drawer C, alevelling piece (compensator K) must bemounted (see Installation instructionsJ182.51).
X
B C
K
Compensators contained in the set:8 mm, 12 mm, 16 mm
15
V-ZUG Ltd Planning aid J001.059-12Industriestrasse 66, P.O. Box 59, 6301 ZugTel. +41 58 767 67 67, Fax +41 58 767 61 61
Kitchen appliances03.09.14
[email protected], www.vzug.com
103
Base element
870–
910 *
10
5–26
5
86
7–90
7
30–100
63
9–757
1
596 572
585
600
16–22
≥ 580BD
* If the niche height is greater than 910 mm,a plate must be placed underneath the appli-ance or an extra-long decor panel must beused.
Mirror glass Fully integratedOperating panel Bincl. compensator
124-140 mm -
Decor panel D 496-632 mm 639-757
Size of base gap S.
870
222222225
10152330
Min.
Max.
127137
107117
147157167177187197207217225
880
137147
117127
157167177187197207217227235
890
147157
127137
167177187197207217227237245
900
157167
137147
177187197207217227237247255
910
167177
147157
187197207217227237247257265
Min. Sin mm
Niche height H in mm
Dim
ensio
n A
in m
m
H
30–100
A
S
15
V-ZUG Ltd Planning aid J001.059-12Industriestrasse 66, P.O. Box 59, 6301 ZugTel. +41 58 767 67 67, Fax +41 58 767 61 61
Kitchen appliances03.09.14
[email protected], www.vzug.com
104
Tall unit «standard»
A
D
86
7
75
7
87
0
≤
38
1
+1
-2
10
5
596 572
600
≥ 580
1
585
B
12
0
40
Cross-sectionInstallation example
1,5
10
16
(8
/6)
40
D
10
5
C
19
12
7
3
C Removable lower front panel (251)
Niche floor A
G
• Load-bearing capacity of niche floor A: 100 kg
• Given a load of 75 kg per appliance foot G, the niche floor may sag by a max. of 1 mm.
Mirror glassOperating panel Bincl. compensator
124-140 mm
Decor panel D 616-632 mm
Installing extra-long decor panel
≥ 100*
H
6
5
E
F
G
* A continuous underside strip is recommended. E WorktopF Continuous underside stripG Decor panelH Niche height
15
V-ZUG Ltd Planning aid J001.059-12Industriestrasse 66, P.O. Box 59, 6301 ZugTel. +41 58 767 67 67, Fax +41 58 767 61 61
Kitchen appliances03.09.14
[email protected], www.vzug.com
105
16 Accessories
16.1 Control set option (current sensor module with relay module)57
57
94 94
94 180
The control set option serves to control external devices (such as a fan) by a control signal generated by a V-ZUG appliance. Theelectrical properties of both component parts must be known for an effective interface. This requires special clarification andassumes electrotechnical expertise. Planning and installation must therefore only be carried out by an electrotechnical expert.
For 230 V~/max. 16 A:
Article no. For 400 V 3N~/max. 25 A:
Article no.
Control set option SSM230 P60036 Control set option SSM400 P60037comprised of: comprised of: 1 current sensor module cpl. SSM1 P60031 1 current sensor module cpl. SSM2 P600321 relay module cpl. RM P60033 1 relay module cpl. RM P60033
The example connection below shows a standard situation. For detailed planning, refer to document P60.008 which can be obtainedfrom the Head Office in Zug, Tel. + 41 58 767 67 67, or on the Internet from www.vzug.ch.
Power supply system
appliance
e.g. 400 V 2N~
400 V 3N~
Power supply system
external consumer
230 V~
Current sensor module (current transformer)
SSM1 / SSM2
RM
Relay module (control unit)
V-ZUG
appliance
External
consumer
e.g. ventialtion
16
V-ZUG Ltd Planning aid J001.059-12Industriestrasse 66, P.O. Box 59, 6301 ZugTel. +41 58 767 67 67, Fax +41 58 767 61 61
Kitchen appliances03.09.14
[email protected], www.vzug.com
106
16.2 Cookers / ovens / steam cookers / microwaves / coffee machines / warming & systems drawers
Compensation elements
Ventilation grille• Ventilation grilles are needed when glass ceramic hobs are installed above ovens.
• For installation, see installation instructions J402.54.
Niche width 60 cmInstallation above the control panel
35
597 Construction types EURO60-600Short oven without drawerArticle no.H63161 (white)H63163 (nero)H63165 (ChromeClass)
Adapter frame• For installation, see installation instructions J731.050.
Niche width 60 cmInstallation below the appliance
Construction types EURO 60-600
Short ovenwithout drawer
48019.53
5
596
560 60-381Mini oven
Article no.K48135 (ChromeClass)K38134 (glass)
Mounting angle for combination possibilities (art. no. K20198)
• For installation, see installation instructions J337.050.
In the niche mount to the wood left and right.
The appliance is placed on the mounting angle and pushed into theniche.
Front of unit
16
V-ZUG Ltd Planning aid J001.059-12Industriestrasse 66, P.O. Box 59, 6301 ZugTel. +41 58 767 67 67, Fax +41 58 767 61 61
Kitchen appliances03.09.14
[email protected], www.vzug.com
107
Design coverThe design cover covers the intermediate base for EURO niches and is fora combined installation of two appliances e.g. oven 1 and combi-steam 2.The cover is dimensioned for panel overlapping of 4 mm.
• For installation, see installation instructions J340.050.
• Depending on the thickness of the intermediate base b, two variants(nero) of the design cover A are available:
Article no.K37158 (b = 16 mm / a = 10.5 mm)K37159 (b = 19 mm / a = 13.5 mm)
b
aA
1
2
16
V-ZUG Ltd Planning aid J001.059-12Industriestrasse 66, P.O. Box 59, 6301 ZugTel. +41 58 767 67 67, Fax +41 58 767 61 61
Kitchen appliances03.09.14
[email protected], www.vzug.com
108
16.3 Glass ceramic hobs
Designation Article no. Installation instructionsThermal shielding plate set for Toptronic appliances- GK25TE…- GK45TEBS.1, GK45TEBS.1C, GK45TEBS.2F- GK45TEAS, GK45TEASC, GK45TEAS.1F- GK45TEPS, GK45TEPSC, GK45TEPSF- GK35TEPS…
H62542H62622H62617H62616H63266
J402.70
Ventilation protective plate set for installation below induction hobs(Not possible for wok and induction appliances with dial controls)Niche width 600 mmNiche width 825 mmNiche width 900 mm
H61083H61084H61085 J402.48
Niche width 600 mm without sealNiche width 825 mm without sealNiche width 900 mm without seal
H61087H61088H61089
Ventilation grille, height 35 mmfor built-under short ovensType of construction 60-600- White- Nero- ChromeClass- ChromeClass (TouchClean)
H63161H63163H63165H63256
J402.54
Type of construction 60-450- Nero- ChromeClass- ChromeClass (TouchClean)
H60039H60041H60053
J402.50
Type of construction 60-381- Nero- ChromeClass- ChromeClass (TouchClean)
H60033H60035H60049
J402.52
16
V-ZUG Ltd Planning aid J001.059-12Industriestrasse 66, P.O. Box 59, 6301 ZugTel. +41 58 767 67 67, Fax +41 58 767 61 61
Kitchen appliances03.09.14
[email protected], www.vzug.com
109
Designation Article no. Installation instructionsAngle set for flush mounted installation with straight stone cut- Hob size 30- Hob size 40- Hob size 60- Hob size 70- Hob size 80- Hob size 90- Hob size 80 Panorama- Hob size 90 Panorama Appropriate adhesive for mounting in stone worktops: Permabond F246, incl. activator, 50 ml tube. From Silitech AG, 3008 Bern.
H63770H63771H63772H63773H63774H63775H62679H62568
B11502
–
Sealing strip set for flush installationTeppan Yaki (GK16TIYS.1F, GK26TIYS.2F)Other hobs
H62695H62142
J31008.120J004.130
Adjusting brace set for mounting in glass worktopsAdjusting brace set H62510 J416.99
Intermediate support sets for combined installationIntermediate support set for gas (1×) H64140 Intermediate support set for induction (2×) H63789
Cement set for flush installationCement set 86392885 J004.130
Suitable for all absorbent worktop materials (wood and natural stones such as marble, granite).
The set comprises:
Designation Remarks NumberCleaning agent, type T * – 1Spezialprimer Typ 1105 * Flasche à 100 ml
1
Silicon adhesive, black cartridge with nozzle
1
For the remaining, resp. for non-absorbent and artificial stone surfaces, the special primer type 107 *, art. no. 45.2771.76 must beused. Not suitable for polyethylene, polypropylene or Teflon.
* Primer types: Firm name H. OTTO GmbH u. Co., Chemie GK, D-83413 Fridolfing
Good adhesion cannot be obtained on slate or other materials containing oil. The use of such worktop materials is not advised for theflush installation of glass ceramic hobs.
In case of doubt as to the suitablity of cement set materials, especially when using them for the first time, we recommendthat you carry out adhesion trials on test pieces or at non-visible locations.
16
V-ZUG Ltd Planning aid J001.059-12Industriestrasse 66, P.O. Box 59, 6301 ZugTel. +41 58 767 67 67, Fax +41 58 767 61 61
Kitchen appliances03.09.14
[email protected], www.vzug.com
110
16.4 Range hoods
Technical information on the range hoods can be found in the document J328.36 «TechInfo for range hoods» and the pricelist.
Short exhaust air connectionThe exhaust air connection is used for exceptionally low installation heights, e.g. in older properties. Depending on how it is installed,the air resistance can be 30-40 % higher than with the proposed exhaust air connection. This must be taken into account in thedimensioning of the exhaust air piping.
Article no.H41877
The exhaust air connection can be used for the following models:
• DF-E5, DF-E6
• DF-SG5, DF-SG6, DF-SG8, DF-SG9
• DF-SLG5, DF-SLG6, DF-SLG8, DF-SLG9
Protective plate for side wallsThe protective plates for the side walls are needed to protect the sides of the wall unit from grease and moisture.
x
Designation Dimensions(height × depth)
Wall unit depth x Colour Article no.
Protective plate for side walls 235 × 310 mm 330 mm White K26092Protective plate for side walls 235 × 310 mm 330 mm Nero K26093Protective plate for side walls 235 × 310 mm 330 mm ChromeClass K26094Protective plate for side walls 235 × 330 mm 350 mm White H42792Protective plate for side walls 235 × 330 mm 350 mm Nero H42791Protective plate for side walls 235 × 330 mm 350 mm ChromeClass H42790Protective plate for side walls 235 × 350 mm 370 mm White H42795Protective plate for side walls 235 × 350 mm 370 mm Nero H42794Protective plate for side walls 235 × 350 mm 370 mm ChromeClass H42793
16
V-ZUG Ltd Planning aid J001.059-12Industriestrasse 66, P.O. Box 59, 6301 ZugTel. +41 58 767 67 67, Fax +41 58 767 61 61
Kitchen appliances03.09.14
[email protected], www.vzug.com
111
Helically wound pipes
Helically wound pipe Description
d1
Strong, helically wound pipe, sendzimir galvanizedMaterial thickness 0.5 mm1× à 3 m
Article no. d1H42028 ø 125 mmH42029 ø 150 mm
Fastening elements
Pipe clip with thread
M8 (M10)
d1
1/2" (3/4") DescriptionFor mounting the helically wound pipe2-piece set with sound insulation insert, incl. screws and nutsGalvanized steelThread M8
Article no. d1H42049 ø 125 mmH42050 ø 150 mm
Double-threaded pin M8, galvanizedDescriptionFor mounting the pipe clip in the concrete wallLength 40 mm
Article no. H42057
Quick-locking hose clamp
Article no. 33121304 ø 110-130 mm33121336 ø 150 mm
16
V-ZUG Ltd Planning aid J001.059-12Industriestrasse 66, P.O. Box 59, 6301 ZugTel. +41 58 767 67 67, Fax +41 58 767 61 61
Kitchen appliances03.09.14
[email protected], www.vzug.com
112
Connecting nipples / connecting pipes
Connecting nipple
d1
L
DescriptionSendzimir galvanized sheet steel L = 80 mm
Article no. d1H42030 ø 125 mmH42031 ø 150 mmH40169 ø 160 mm
Connecting pipe
d1
L
DescriptionSendzimir galvanized sheet steel L = 90 mm
Article no. d1H42032 ø 125 mmH412033 ø 150 mm
Cladding elbow
Cladding elbow
d140
d1
45
Formwork
DescriptionFor installation on formworkSpecially for inlays in concrete ceilingSendzimir galvanized sheet steel
Article no. d1H42038 ø 125 mmH42039 ø 150 mm
16
V-ZUG Ltd Planning aid J001.059-12Industriestrasse 66, P.O. Box 59, 6301 ZugTel. +41 58 767 67 67, Fax +41 58 767 61 61
Kitchen appliances03.09.14
[email protected], www.vzug.com
113
Elbows
Elbow 90°
R
d1
DescriptionElbow, pressedUse with flexible and rigid pipesSendzimir galvanized sheet steelR = d1
Article no. d1H42034 ø 125 mmH42036 ø 150 mm
Elbow 45°
R
d1 DescriptionElbow, pressedUse with flexible and rigid pipesSendzimir galvanized sheet steelR = d1
Article no. d1H42035 ø 125 mmH42037 ø 150 mm
Reducers
Reducer
d1 d2
L
DescriptionPressed versionSendzimir galvanized sheet steel L = 22 mm
Article no. d1-d2H42040 ø 150-125 mm
16
V-ZUG Ltd Planning aid J001.059-12Industriestrasse 66, P.O. Box 59, 6301 ZugTel. +41 58 767 67 67, Fax +41 58 767 61 61
Kitchen appliances03.09.14
[email protected], www.vzug.com
114
Tee pieces
Tee 45°
40 d3
d1
L
DescriptionUse with flexible and rigid pipesFlow-enhancingSendzimir galvanized sheet steel L = 300 mmd3 = 125 mm
Article no. d1H42042 ø 150 mm
Y-pipes
45° y-pipe
L
d3d4
d1
45˚45˚
DescriptionUse with flexible and rigid pipesSendzimir galvanized sheet steel L = d1 = 150 mmd3 = 125 mmd4 = 100 mm
Article no. d1H42045 ø 150 mm
30° y-pipe
L
d3d4
d1
30˚30˚
DescriptionUse with flexible and rigid pipesSendzimir galvanized sheet steel L = d1 = 150 mmd3 = 125 mmd4 = 100 mm
Article no. d1H42046 ø 150 mm
16
V-ZUG Ltd Planning aid J001.059-12Industriestrasse 66, P.O. Box 59, 6301 ZugTel. +41 58 767 67 67, Fax +41 58 767 61 61
Kitchen appliances03.09.14
[email protected], www.vzug.com
115
Pipe end pieces
Pipe end piece
d1
DescriptionConnection with grilleSendzimir galvanized sheet steel
Article no. d1H42047 ø 125 mmH42048 ø 150 mm
Weather protection grilles
Weather protection grille
d1
L DescriptionWeather protection grille without a non-return flap valve, round,pressed, made from aluminiumWith fly screen and connection piece L = 45 mm
Article no. d1H42063 ø 125 mmH42064 ø 150 mm
Weather protection grille made from plastic
d1 20
0
L
200
DescriptionWeather protection grille without a non-return flap valve, squarewith connection pieceWeatherproof L = 40 mm
Article no. d1H42058 White, ø 125 mmH42059 Beige, ø 125 mmH42060 Brown, ø 125 mmH42080 White, ø 150 mmH42081 Beige, ø 150 mmH42082 Brown, ø 150 mm
16
V-ZUG Ltd Planning aid J001.059-12Industriestrasse 66, P.O. Box 59, 6301 ZugTel. +41 58 767 67 67, Fax +41 58 767 61 61
Kitchen appliances03.09.14
[email protected], www.vzug.com
116
Wall pipes
Telescopic wall pipe with non-return flap valve
d1
L Description3-partSendzimir galvanized sheet steelGrille made from aluminium; can be painted L = Wall thickness 300-460 mm
Article no. d1H42065 ø 125 mmH42066 ø 150 mm
Flaps
Non-return flap valve with sealing lip
L
d1
DescriptionMade from robust sheet steelFor flexible and rigid pipes L = 80 mm
Article no. d1H42061 ø 125 mmH42062 ø 150 mm
Motor flap, complete, 230V
d1
21
0
80
DescriptionConsisting of motor, flap lever and regulating flap with gasketSendzimir galvanized sheet steel
Article no. d1H43390 ø 125 mmH43391 ø 150 mm
16
V-ZUG Ltd Planning aid J001.059-12Industriestrasse 66, P.O. Box 59, 6301 ZugTel. +41 58 767 67 67, Fax +41 58 767 61 61
Kitchen appliances03.09.14
[email protected], www.vzug.com
117
Hoses
Aluminium hose, semi-flexible Description
d1
Round Aluflex, semi-flexibleDimensionally stable, flame resistant1× à 3 m
Article no. d1H42051 ø 125 mmH42052 ø 150 mmH40168 ø 160 mm
Aluminium hose, highly flexible Description
d1
Round Aluflex, highly flexibleInternal bending radius 30-60 mmDimensionally stable, flame resistant1× à 10 m
Article no. d1H42053 ø 125 mm16955803 ø 150 mm
Aluminium hose, insulated Description
d1
Round Aluflex, highly flexibleSound-insulating 25 mm1× à 10 m
Article no. d1H42055 ø 125 mmH42056 ø 150 mm
Rectangular aluminium hose
54
140/180
DescriptionAluflex, highly flexibleReinforced with 2 layers of polyester and 3 layers of aluminiumFlame resistantOnly suitable for short exhaust ductsPay attention to back pressure.1× à 10 m
Article no. d1H42083 54 × 140 mm (ø 125 mm)H42084 54 × 180 mm (ø 150 mm)
16
V-ZUG Ltd Planning aid J001.059-12Industriestrasse 66, P.O. Box 59, 6301 ZugTel. +41 58 767 67 67, Fax +41 58 767 61 61
Kitchen appliances03.09.14
[email protected], www.vzug.com
118
Flat channels
Flat channel
82
254L
DescriptionExhaust ducting system with very low installation height of 82 mmSendzimir galvanized sheet steelCorresponds to nominal diameter ø of 150 mm
Article no. H42068 L = 1000 mmH42069 L = 600 mm
Reinforced flat channel
82
254L
DescriptionExhaust ducting system with very low installation height of 82 mmSendzimir galvanized sheet steelWith reinforcement for concreting inCorresponds to nominal diameter ø of 150 mm
Article no. H42085 L = 600 mmH42086 L = 1000 mm
Telescopic flat channel
254L
82
DescriptionExhaust ducting system with very low installation height of 82 mmSendzimir galvanized sheet steelCorresponds to nominal diameter ø of 150 mm
Article no. H42070 L = 275-535 mm
Reinforcing rib for flat channel
L
DescriptionFor concreting in flat channel
Article no. H42071 L = 600 mmH42072 L = 1000 mm
Mounting bracket for flat channel
257
82
Article no. H42073
16
V-ZUG Ltd Planning aid J001.059-12Industriestrasse 66, P.O. Box 59, 6301 ZugTel. +41 58 767 67 67, Fax +41 58 767 61 61
Kitchen appliances03.09.14
[email protected], www.vzug.com
119
Elbow 90°, vertical, for flat channel
14
0
254
82
Article no. H42074
Elbow 45°, vertical, for flat channel
16
0
254
82
Article no. H42075
Elbow 90°, horizontal, for flat channel
254
315
82
Article no. H42076
Elbow 45°, horizontal, for flat channel
254
280
82
Article no. H42077
16
V-ZUG Ltd Planning aid J001.059-12Industriestrasse 66, P.O. Box 59, 6301 ZugTel. +41 58 767 67 67, Fax +41 58 767 61 61
Kitchen appliances03.09.14
[email protected], www.vzug.com
120
Transition piece for flat channel
14
5
254
82
d1 DescriptionFor transitioning from round to flat
Article no. H42078
Diverter piece on flat channel
60
82
115
200 254
Article no. H42087 Connection ø 125 mmH42079 Connection ø 150 mm
Flat channel wall box
150
150300
DescriptionWith non-return flap valve and weather protection grille
Article no. H42054
Sealing tape
Aluminium tapeDescriptionFabric-reinforced tape, with protective film50 mm × 50 m roll
Article no. H42067
16
V-ZUG Ltd Planning aid J001.059-12Industriestrasse 66, P.O. Box 59, 6301 ZugTel. +41 58 767 67 67, Fax +41 58 767 61 61
Kitchen appliances03.09.14
[email protected], www.vzug.com
121
16.5 Refrigerators
Designation Article no. RemarksSupplementary kit 60 cm (filler strip)- KFi, KRi, KLi, KIi- KCi, KNi, KPRPieco, KPRieco, KPRi, KCLi
H71755H71756
Length 1530 mmLength 1780 mm
Bottle rack- KMi 60 eco
H72731
–
16.6 Dishwashers
Adora
Stainless steel fronts (option)Integrated Width Height Depth Article no.Decor set 60 standard ChromeClass 596 mm 632 mm 20 mm W83523Decor set 60 extra height ChromeClass 596 mm 697 mm 20 mm W83524
Mirror glass fronts (option)Integrated Width Height Depth Article no.Decor set 60 standard mirror glass 596 mm 632 mm 20 mm W83526Decor set 60 extra height mirror glass 596 mm 697 mm 20 mm W83527
Diverse setsSet Article no. RemarksConversion kit for slide plate W83583 In place of the plinth runners, for the installation on a plinth or for the tall
unit.Installation set, fully integrated, two-part W83931 For a two-part, fully integrated decor front panel.Compensator set, ChromeClass W81302 Supplied for «ChromeClass» appliances.Compensator set, black W82043 Additional order for «Mirror glass» appliances.
The set can also be used for «ChromeClass» appliances.Plinth runner W82930 For height compensation in a nicheWork surface protection W70163 Protection against escaping moistureCS set containing strong spring W84603 For heavier decor panels, standard height, weight of decor panel max.
10.5 kgCS set containing strong spring W84604 For heavier decor panels, extra height, weight of decor panel max.
10.5 kgCS set containing long hoses SL W86140 Conversion to 3 m Aqua-Stop and 3 m drain hose*CS set containing long hoses N/S W86139 Conversion to 3 m Aqua-Stop and 3 m drain hose*
* The conversion should be carried out by trained personnel only.
16
V-ZUG Ltd Planning aid J001.059-12Industriestrasse 66, P.O. Box 59, 6301 ZugTel. +41 58 767 67 67, Fax +41 58 767 61 61
Kitchen appliances03.09.14
[email protected], www.vzug.com
122
Notes
V-ZUG Ltd Planning aid J001.059-12Industriestrasse 66, P.O. Box 59, 6301 ZugTel. +41 58 767 67 67, Fax +41 58 767 61 61
Kitchen appliances03.09.14
[email protected], www.vzug.com
123
V-ZUG Ltd Planning aid J001.059-12Industriestrasse 66, P.O. Box 59, 6301 ZugTel. +41 58 767 67 67, Fax +41 58 767 61 61
Kitchen appliances03.09.14
[email protected], www.vzug.com
124
V-ZUG Ltd Planning aid J001.059-12Industriestrasse 66, P.O. Box 59, 6301 ZugTel. +41 58 767 67 67, Fax +41 58 767 61 61
Kitchen appliances03.09.14
[email protected], www.vzug.com
125
Index
AAccessories ..........................................................................106
Adapter frame ............................................................... 107Compensation elements for combination possibilities .. 107Design cover ................................................................. 108for cookers, ovens, steam cookers, microwaves .......... 107for glass ceramic hobs .................................................. 109for range hoods ............................................................. 111for refrigerators .............................................................. 122
Adapter frame ......................................................................107Adjusting brace set ..............................................................110Air outlet cassette (LAC) ........................................................86Air recycling cassette (LRC) ..................................................86Ancillary equipment
Control set option .......................................................... 106Angle set ..............................................................................110
BBuilt-in hoods .........................................................................77
CCement set ...........................................................................110Coffee machines
Accessories ................................................................... 107Combination possibilities
Ovens .............................................................................. 11Steam cookers ................................................................ 16
Compensation elementsAdapter frame ............................................................... 107Design cover ................................................................. 108Mounting angle for combination possibilities ................. 107Ventilation grille ............................................................. 107
Compensator .........................................................................95Control set option .................................................................106Controlling external devices .................................................106Cookers
Accessories ................................................................... 107Country groups ........................................................................2Current sensor module with relay module ...........................106
DDesign cover ........................................................................108Dishwashers
Accessories ................................................................... 122Compensator ................................................................... 95Electrical connection data ............................................... 92Plumbing-in data ............................................................. 92
Dishwashers with heat pump ...............................................100Compensator ................................................................. 103Electrical connection data ............................................. 101Plumbing-in data ........................................................... 101
EElectrical connection data
Adora dishwashers .................................................. 91, 100Ovens .............................................................................. 10Toptronic hobs ................................................................ 46Warming and system drawers ......................................... 19
Electrical connectionsGeneral operating conditions ............................................ 5Steam cookers ................................................................ 12
Electrical connections and installation dimensions ..................5Exhaust air connection .........................................................111
FFrequency stability ...................................................................5Frequency variation .................................................................5Front dimensions of the appliances
Manufacturing tolerance .................................................... 9
GGeneral operating conditions ...................................................5Glass ceramic hobs
Accessories ................................................................... 109Examples for combined installation ................................. 59Hobs for the replacement market .................................... 53Induction hobs ................................................................. 28Toptronic hobs ................................................................ 46
HHeatable appliance drawers ..................................................19Hobs
Accessories ................................................................... 107
IInduction hobs ........................................................................28Induction woks .......................................................................28Installation dimensions .............................................................5
Front dimensions ............................................................... 9Island hoods ...........................................................................69
MMicrowaves
Accessories ................................................................... 107Mounting angle for combination possibilities .......................107
OOperating conditions
General ............................................................................. 5Ovens
Accessories ................................................................... 107Combination possibilities ................................................. 11Electrical connection data ............................................... 10
PPlumbing in
Adora dishwashers .................................................. 91, 100Positions of electrical connections
Range hoods ................................................................... 72
V-ZUG Ltd Planning aid J001.059-12Industriestrasse 66, P.O. Box 59, 6301 ZugTel. +41 58 767 67 67, Fax +41 58 767 61 61
Kitchen appliances03.09.14
[email protected], www.vzug.com
126
RRange hoods ..........................................................................68
Air outlet cassette (LAC) ................................................. 86Air recycling cassette (LRC) ............................................ 86Built-in hoods .................................................................. 77Cladding elbow .............................................................. 113Connecting nipples ........................................................ 113Connecting pipes ........................................................... 113Elbow ............................................................................ 114Exhaust air connection .................................................. 111Fastening elements ....................................................... 112Flaps ............................................................................. 117Flat channels ................................................................. 119Helically wound pipes .................................................... 112Hoses ............................................................................ 118Island hoods .................................................................... 69Pipe end pieces ............................................................. 116Positions of electrical connections .................................. 72Reducers ....................................................................... 114Sealing tape .................................................................. 121TechInfo for range hoods .............................................. 111Tee pieces ..................................................................... 115Wall hoods ...................................................................... 72Wall pipes ...................................................................... 117Weather protection grilles .............................................. 116Y-pipes .......................................................................... 115
Refrigerators ..........................................................................87
SSealing strip set ...................................................................110Steam cookers .......................................................................12
Accessories ................................................................... 107Installation ....................................................................... 14plumbing in ...................................................................... 15
Supplementary documents ......................................................2TechInfo for range hoods .............................................. 111
Symbols used ..........................................................................2System drawers .....................................................................19
Accessories ................................................................... 107
TTechInfo for range hoods .....................................................111Thermal shielding plate set ..................................................109Toptronic hobs .......................................................................46
UUse at altitude ..........................................................................5
VValidity .....................................................................................5Ventilation grille ............................................................107, 109Ventilation protective plate set .............................................109
WWall hoods .............................................................................72Warming and system drawers
Electrical connection data ............................................... 19Warming drawers
Accessories ................................................................... 107
V-ZUG Ltd Planning aid J001.059-12Industriestrasse 66, P.O. Box 59, 6301 ZugTel. +41 58 767 67 67, Fax +41 58 767 61 61
Kitchen appliances03.09.14
[email protected], www.vzug.com
127
V-ZUG Ltd – in the centre of Europe,in the heart of Switzerland
Welcome! V-ZUG Ltd Industriestrasse 66 P.O. Box 59 6301 Zug, Switzerland Tel. +41 58 767 67 78 [email protected] www.vzug.com
The Swiss Leader