128
Planning aid Kitchen appliances 2014/15

Planning aid Kitchen appliances - V-ZUG AG · Kitchen appliances 03.09.14 [email protected], 9. 2 Ovens 2.1 Electrical connection data Appliance Country group * Mains connection Fuse

  • Upload
    others

  • View
    6

  • Download
    0

Embed Size (px)

Citation preview

Page 1: Planning aid Kitchen appliances - V-ZUG AG · Kitchen appliances 03.09.14 info@vzug.com, 9. 2 Ovens 2.1 Electrical connection data Appliance Country group * Mains connection Fuse

Planning aidKitchen appliances

2014/15

Page 2: Planning aid Kitchen appliances - V-ZUG AG · Kitchen appliances 03.09.14 info@vzug.com, 9. 2 Ovens 2.1 Electrical connection data Appliance Country group * Mains connection Fuse

Note on content

Please noteThis planning aid is not to be used as installation instructions! The regulations and instructions binding for the appliance installationare to be obtained from the installation instructions packed with the appliances. The installation instructions can also be downloadedfrom the internet from www.vzug.com/b2b.

ModificationsText, diagrams and data correspond to the technical standard of the appliances at the time this planning aid went to press. The rightto make technical modifications for the purpose of the further development of the appliances is reserved.

Symbols used

Denotes important safety precautions.Failure to observe said precautions can result in injury or in damage to the appliance or fittings!

Indicates an instruction.

• Indicates a list.

Information and precautions that should be observed.

Supplementary documentsIn this planning aid, occasional reference is made to supplementary documents These documents can be obtained from the HeadOffice in Zug, Tel. + 41 58 767 67 78 or by e-mail from [email protected].

Key to country groups

Countrygroup

Country code(in accordance with ISO 3166)

Countrygroup

Country code(in accordance with ISO 3166)

A EU European UnionTR TurkeyIL IsraelLB Lebanon

D AU AustraliaNZ New Zealand

B GB Great BritainHK Hong KongSG Singapore

E RU RussiaUA Ukraine

C NO Norway F CN China

V-ZUG Ltd Planning aid J001.059-12Industriestrasse 66, P.O. Box 59, 6301 ZugTel. +41 58 767 67 67, Fax +41 58 767 61 61

Kitchen appliances03.09.14

[email protected], www.vzug.com

2

Page 3: Planning aid Kitchen appliances - V-ZUG AG · Kitchen appliances 03.09.14 info@vzug.com, 9. 2 Ovens 2.1 Electrical connection data Appliance Country group * Mains connection Fuse

Contents

1 Overview of connections, ranges and dimensions 5 1.1 General operating conditions .............................................................................................................................................. 5 1.2 Validity ................................................................................................................................................................................ 5 1.3 Front dimensions of the appliances .................................................................................................................................... 92 Ovens 10 2.1 Electrical connection data ................................................................................................................................................... 10 2.2 Combair SLP (51A), SL (48A), SEP (45A), SE (42A) ......................................................................................................... 10 2.3 Combair XSL (49A), XSE (43A), XSLP (21026), XSEP (21020) ........................................................................................ 10 2.4 Hotair HSE (28A), Combair HSE (30A) .............................................................................................................................. 10 2.5 Combination possibilities .................................................................................................................................................... 113 Steam cookers 12 3.1 Electrical connection data ................................................................................................................................................... 12 3.2 Combair-Steam S (63A), N (61A) ....................................................................................................................................... 12 3.3 Combi-Steam SL (58A), Steam S (56A) ............................................................................................................................. 12 3.4 Combi-Steam XSL (59A) .................................................................................................................................................... 12 3.5 Combi-Steam XSLF (68A) .................................................................................................................................................. 13 3.6 Combination possibilities .................................................................................................................................................... 164 Coffee-Centers 17 4.1 Electrical connection data ................................................................................................................................................... 17 4.2 Supremo SL (75A) .............................................................................................................................................................. 17 4.3 Supremo XSL (76A) ............................................................................................................................................................ 17 4.4 Combination possibilities .................................................................................................................................................... 185 Warming and system drawers 19 5.1 General notes ..................................................................................................................................................................... 19 5.2 Electrical connection data ................................................................................................................................................... 19 5.3 Warming drawers with niche width 60 cm ........................................................................................................................... 20 5.4 System drawers with niche width 60 cm ............................................................................................................................. 236 Microwaves 24 6.1 Electrical connection data ................................................................................................................................................... 24 6.2 Miwell-Combi SL (947), XSL (939), Miwell SL (945) ........................................................................................................... 24 6.3 Miwell L (24002) .................................................................................................................................................................. 25 6.4 Combination possibilities .................................................................................................................................................... 267 Glass ceramic hobs – induction, wok, teppanyaki 28 7.1 General notes ..................................................................................................................................................................... 28 7.2 Electrical connection data ................................................................................................................................................... 29 7.3 Ventilation ........................................................................................................................................................................... 29 7.4 Operation ............................................................................................................................................................................ 29 7.5 Framed installation .............................................................................................................................................................. 30 7.6 Flush installation ................................................................................................................................................................. 35 7.7 Installation without protective plate ..................................................................................................................................... 41 7.8 Installation with protective plate .......................................................................................................................................... 43 7.9 Installing above oven / steam cooker .................................................................................................................................. 458 Toptronic glass ceramic hobs 46 8.1 General notes ..................................................................................................................................................................... 46 8.2 Electrical connection data ................................................................................................................................................... 46 8.3 Framed installation .............................................................................................................................................................. 47 8.4 Flush installation ................................................................................................................................................................. 509 Glass ceramic hobs for the replacement market 53 9.1 Appliances for the replacement market – induction ............................................................................................................ 53 9.2 Appliances for the replacement market – Toptronic ........................................................................................................... 5810 Examples for combined appliance installation 59

11 Gas hobs & lava grills 60 11.1 Gas hobs ............................................................................................................................................................................. 60 11.2 Lava grill .............................................................................................................................................................................. 63 11.3 2-zone induction hob ........................................................................................................................................................... 63 11.4 Installation examples for combined gas edition arrangement ............................................................................................. 6412 Range hoods 68 12.1 General notes ..................................................................................................................................................................... 68 12.2 Island hoods ........................................................................................................................................................................ 69

V-ZUG Ltd Planning aid J001.059-12Industriestrasse 66, P.O. Box 59, 6301 ZugTel. +41 58 767 67 67, Fax +41 58 767 61 61

Kitchen appliances03.09.14

[email protected], www.vzug.com

3

Page 4: Planning aid Kitchen appliances - V-ZUG AG · Kitchen appliances 03.09.14 info@vzug.com, 9. 2 Ovens 2.1 Electrical connection data Appliance Country group * Mains connection Fuse

12.3 Wall hoods .......................................................................................................................................................................... 72 12.4 Built-in hoods ...................................................................................................................................................................... 77 12.5 Air recycling cassette (LRC) ............................................................................................................................................... 86 12.6 Air outlet cassette (LAC) ..................................................................................................................................................... 8613 Refrigerators 87 13.1 General notes ..................................................................................................................................................................... 87 13.2 Electrical connection data ................................................................................................................................................... 87 13.3 Room temperature .............................................................................................................................................................. 87 13.4 Niche ventilation .................................................................................................................................................................. 87 13.5 Refrigerators ....................................................................................................................................................................... 88 13.6 Winecoolers ........................................................................................................................................................................ 9014 Dishwashers 91 14.1 General notes ..................................................................................................................................................................... 91 14.2 Electrical connection data / plumbing in .............................................................................................................................. 91 14.3 Installation summary ........................................................................................................................................................... 93 14.4 Drilling plans for decor panel 60 cm .................................................................................................................................... 94 14.5 Adora SL, S, N with niche width 60 cm ............................................................................................................................... 9515 Dishwashers with heat pump 100 15.1 General notes ..................................................................................................................................................................... 100 15.2 Electrical connection data / plumbing in .............................................................................................................................. 100 15.3 Installation summary ........................................................................................................................................................... 102 15.4 Drilling plans for decor panel 60 cm .................................................................................................................................... 102 15.5 Adora SL WP with niche width 60 cm ................................................................................................................................. 10316 Accessories 106 16.1 Control set option (current sensor module with relay module) ............................................................................................ 106 16.2 Cookers / ovens / steam cookers / microwaves / coffee machines / warming & systems drawers .................................... 107 16.3 Glass ceramic hobs ............................................................................................................................................................ 109 16.4 Range hoods ....................................................................................................................................................................... 111 16.5 Refrigerators ....................................................................................................................................................................... 122 16.6 Dishwashers ....................................................................................................................................................................... 122

V-ZUG Ltd Planning aid J001.059-12Industriestrasse 66, P.O. Box 59, 6301 ZugTel. +41 58 767 67 67, Fax +41 58 767 61 61

Kitchen appliances03.09.14

[email protected], www.vzug.com

4

Page 5: Planning aid Kitchen appliances - V-ZUG AG · Kitchen appliances 03.09.14 info@vzug.com, 9. 2 Ovens 2.1 Electrical connection data Appliance Country group * Mains connection Fuse

1 Overview of connections, ranges and dimensions

Electrical connections must be carried out by qualified experts.Plan a separate inlet for the electrical connection for each appliance.

1.1 General operating conditions

Detailed information on the electrical connection data can be found at the beginning of each section.

Value Nominal value Minimum MaximumVoltage 230 V

400 V207 V360 V

253 V440 V

Frequency 50 Hz sinusoidal 49 Hz sinusoidal 51 Hz sinusoidal

Short duration frequency variation in the mains: ± 5 %

Long duration frequency stability in the mains (for synchronous clocks): ± 10 ppm

The appliances are designed for use up to a max. altitude of 2000 m above sea level.

1.2 Validity

The product family (model number) corresponds to the first alphanumerics on the identification plate.

Ovens

Type Product familyCombair HSE 30ACombair SE 42ACombair SEP 45ACombair SL 48ACombair SLP 51ACombair XSE 43ACombair XSEP 21020Combair XSL 49ACombair XSLP 21026Hotair HSE 28A

Steam cookers

Type Product familyCombair-Steam N 61ACombair-Steam S 63ACombi-Steam SL 58ACombi-Steam XSL 59ACombi-Steam XSLF 68ASteam S 56A

Coffee-Centers

Type Product familySupremo SL 75ASupremo XSL 76A

1

V-ZUG Ltd Planning aid J001.059-12Industriestrasse 66, P.O. Box 59, 6301 ZugTel. +41 58 767 67 67, Fax +41 58 767 61 61

Kitchen appliances03.09.14

[email protected], www.vzug.com

5

Page 6: Planning aid Kitchen appliances - V-ZUG AG · Kitchen appliances 03.09.14 info@vzug.com, 9. 2 Ovens 2.1 Electrical connection data Appliance Country group * Mains connection Fuse

Warming & system drawers

Type Product familySYS 60/144 620SYS 60/76 953WS 60/144 34003WS 60/162 34004WS 60/220 34005WS 60/283 34006

Microwave ovens

Type Product familyMiwell L 24002Miwell SL 945Miwell-Combi SL 947Miwell-Combi XSL 939

Glass ceramic induction

Type Product familyGK16TIWS.1F 31010GK16TIWSF 87AGK16TIYS.1F 31008GK16TIYSF 85AGK26TIMS, GK26TIMSF 84AGK26TIMS.1F 31011GK26TIMS.2F 31001GK26TIYS.1F 31009GK26TYSF 86AGK36TIPS, GK36TIPSC, GK36TIPSF 975GK36TIS, GK36TISC, GK36TISF 008GK36TIS.1F 31013GK46IABD, GK46IABDC, GK46IABDF 96AGK46IABD.1F 31022GK46ID, GK46IDC, GK46ID.1F, GK46IDF 31021GK46TIABS, GK46TIABSC, GK46TIABSF 028GK46TIABS.1F 31017GK46TIAKS, GK46TIAKSC, GK46TIAKSF 90AGK46TIMAS, GK46TIMASC, GK46TIMASF 31030GK46TIMPS, GK46TIMPSC, GK46TIMPSF 31029GK46TIMS, GK46TIMSC, GK46TIMSF 88AGK46TIMS.1F 31014GK46TIMXSC, GK46TIMXSF 31002GK46TIPS, GK46TIPSC, GK46TIPSF 973GK56TIMS, GK56TIMSC, GK56TIMSF 89AGK56TIMS.1F 31020

1

V-ZUG Ltd Planning aid J001.059-12Industriestrasse 66, P.O. Box 59, 6301 ZugTel. +41 58 767 67 67, Fax +41 58 767 61 61

Kitchen appliances03.09.14

[email protected], www.vzug.com

6

Page 7: Planning aid Kitchen appliances - V-ZUG AG · Kitchen appliances 03.09.14 info@vzug.com, 9. 2 Ovens 2.1 Electrical connection data Appliance Country group * Mains connection Fuse

Glass ceramic Toptronic

Type Product familyGK25TE 005GK25TE.1F 31023GK35TEPS, GK35TEPSC, GK35TEPSF 31032GK45TEAS, GK45TEASC, GK45TEASF 977GK45TEAS.1F 31026GK45TEBS.1, GK45TEBS.1C, GK45TEBS.1F 032GK45TEBS.2F 31028GK45TEPS, GK45TEPSC, GK45TEPSF 976

Gas hobs & lava grills

Type Product familyGK1121TGCN 31035GK11TG 798GK11TKLG 98AGK11TTG 851GK21TG 797GK21TI 834GK21TTG 302GK41TG 717GK51TPG 701

Island hoods

Type Product familyDIPQ10 63007DI-B10 816DI-B12 93008DI-B14 821DI-M10 996DI-M12 997DIPQ13 63006DI-SE10 076DI-SE12 077

Wall hoods

Type Product familyDWPQ12 62006DW-B12 62008DW-B14 994DW-B9 993DW-F8 042DW-L9 990DW-M12 992DWPQ9 62007DW-SE12 068DW-SW9 059SW-M9 991

1

V-ZUG Ltd Planning aid J001.059-12Industriestrasse 66, P.O. Box 59, 6301 ZugTel. +41 58 767 67 67, Fax +41 58 767 61 61

Kitchen appliances03.09.14

[email protected], www.vzug.com

7

Page 8: Planning aid Kitchen appliances - V-ZUG AG · Kitchen appliances 03.09.14 info@vzug.com, 9. 2 Ovens 2.1 Electrical connection data Appliance Country group * Mains connection Fuse

Built-in hoods

Type Product familyDFPQ12 61013DFPQ6 61015DFPQ9 61014DFPQSL6 61008DFPQSL9 61007DF-SG6 360DF-SG9 549DF-SLG6 384DF-SLG9 385DHL11 64002DHL8 64001

Refrigerators

Type Product familyCooltronic 60i 51029De Luxe 60i 51017Futura 60i 51020Komfort 60i 51048Magnum 60i eco 51031Noblesse 60i 51028Prestige 60i 51027Prestige P 60i eco 51052Royal 60i 51018Winecooler SL 629

Dishwashers

Type Product familyAdora N 41011, 41029, 41030-41033Adora S 41010, 41016, 41034-41037Adora SL 41005-41008, 41042, 41043Adora SL WP 41009, 41038

1

V-ZUG Ltd Planning aid J001.059-12Industriestrasse 66, P.O. Box 59, 6301 ZugTel. +41 58 767 67 67, Fax +41 58 767 61 61

Kitchen appliances03.09.14

[email protected], www.vzug.com

8

Page 9: Planning aid Kitchen appliances - V-ZUG AG · Kitchen appliances 03.09.14 info@vzug.com, 9. 2 Ovens 2.1 Electrical connection data Appliance Country group * Mains connection Fuse

1.3 Front dimensions of the appliances

Manufacturing tolerance: ±1 mm

Applianceheight H

Fascia height H1 Door glass heightH2

Design handle G1 Handle length

598 124 457.5 43 415454 80 357.5 43 415378 50 311.5

Appliance without drawer

X

8.5

Y

8

35

20

H1

G1

H2

H

Detail XDetail X

4 m

m

Ove

rla

pp

ing

Ap

plia

nce

he

igh

t

Nic

he

he

igh

t

Detail Y

4

1

V-ZUG Ltd Planning aid J001.059-12Industriestrasse 66, P.O. Box 59, 6301 ZugTel. +41 58 767 67 67, Fax +41 58 767 61 61

Kitchen appliances03.09.14

[email protected], www.vzug.com

9

Page 10: Planning aid Kitchen appliances - V-ZUG AG · Kitchen appliances 03.09.14 info@vzug.com, 9. 2 Ovens 2.1 Electrical connection data Appliance Country group * Mains connection Fuse

2 Ovens

2.1 Electrical connection data

Appliance Country group * Mains connection Fuse Rated load Mains cableCombair SLP, SL, SE, SEPCombair XSLP, XSEPCombair XSL, XSECombair HSE

A, C, E 230 V~ 50 Hz

16 A

SL(P), SE(P): 3400 WXSL(P), XSE(P): 3300 W

HSE: 3100 W

2.5 m, with plugB 2.5 m, without

plugD 220-240 V~ 50 HzF 2.5 m, with plug

Hotair HSE A, B, C, E 230 V~ 50 Hz 10 A 2400 W 2.1 m, with plugD, F 220-240 V~ 50 Hz

* Note on content [➙ see page 2]

2.2 Combair SLP (51A), SL (48A), SEP (45A), SE (42A)

59

8

569

440

596

59

4

600

≥ 550

560–568

X

Y

440569

600

600

≥ 550

598

596

560–568

2.3 Combair XSL (49A), XSE (43A), XSLP (21026), XSEP (21020)

454

596

569

600

≥ 550

450

560–568

X

346

Y

2.4 Hotair HSE (28A), Combair HSE (30A)

37

8

596

569

295

600

≥ 550

37

4

560–568

X

Y

Front dimensions of the appliances: Detail X/Y [➙ see page 9]

2

V-ZUG Ltd Planning aid J001.059-12Industriestrasse 66, P.O. Box 59, 6301 ZugTel. +41 58 767 67 67, Fax +41 58 767 61 61

Kitchen appliances03.09.14

[email protected], www.vzug.com

10

Page 11: Planning aid Kitchen appliances - V-ZUG AG · Kitchen appliances 03.09.14 info@vzug.com, 9. 2 Ovens 2.1 Electrical connection data Appliance Country group * Mains connection Fuse

2.5 Combination possibilities

Hotair HSE, Combair HSE & oven

≥ 550

600

560–568

596 569

598

378

974

374

X

W

Y

≥ 550

600

560–568

974

594

596 569

378

598

X

W

Y

Hotair HSE, Combair HSE & steam cooker

≥ 550

600

560–568

596 569

378

378

754

374

X

W

Y

Combair XSL, XSE & oven

≥ 550

600

560–568

596 569

598

454

1050

450

X

W

Y

Combair XSL, XSE & Combi-Steam XSL

≥ 550

600

560–568

596 569

45

44

54

90

6

45

0

X

W

Y

W = Angle set K20198

If installing with a second appliance in the same niche, use the angle set 60 W (K20198).

Front dimensions of the appliances: Detail X/Y [➙ see page 9]

2

V-ZUG Ltd Planning aid J001.059-12Industriestrasse 66, P.O. Box 59, 6301 ZugTel. +41 58 767 67 67, Fax +41 58 767 61 61

Kitchen appliances03.09.14

[email protected], www.vzug.com

11

Page 12: Planning aid Kitchen appliances - V-ZUG AG · Kitchen appliances 03.09.14 info@vzug.com, 9. 2 Ovens 2.1 Electrical connection data Appliance Country group * Mains connection Fuse

3 Steam cookersOnly use if water hardness > 3 French degrees (> 1.7 German degrees) possible.

3.1 Electrical connection data

Appliance Country group * Mains connection Fuse Rated load Mains cable Combair-Steam S, NCombi-Steam XSL, XSLF, SL

A, C, E 230 V~ 50 Hz

16 AS, N, XSL(F): 3700 W

SL: 3500 W

2.1 m, with plugB 2.1 m, without

plugD 220-240 V~ 50 HzF

2.1 m, with plugSteam S

A, B, C, E 230 V~ 50 Hz 10 A 2200 WD, F 220-240 V~ 50 Hz

* Note on content [➙ see page 2]

3.2 Combair-Steam S (63A), N (61A)

59

8

569

440

596

59

4

600

≥ 550

560–568

X

Y

440569

600

600

≥ 550

598

596

560–568

3.3 Combi-Steam SL (58A), Steam S (56A)

37

8

596

569

295

600

≥ 550

37

4

560–568

X

Y

3.4 Combi-Steam XSL (59A)

454

596

569

600

≥ 550

450

560–568

X

346

Y

Front dimensions of the appliances: Detail X/Y [➙ see page 9]

3

V-ZUG Ltd Planning aid J001.059-12Industriestrasse 66, P.O. Box 59, 6301 ZugTel. +41 58 767 67 67, Fax +41 58 767 61 61

Kitchen appliances03.09.14

[email protected], www.vzug.com

12

Page 13: Planning aid Kitchen appliances - V-ZUG AG · Kitchen appliances 03.09.14 info@vzug.com, 9. 2 Ovens 2.1 Electrical connection data Appliance Country group * Mains connection Fuse

3.5 Combi-Steam XSLF (68A)

454

596

569

600

575

450

560–568

X

346

≥ 40Y

Front dimensions of the appliances: Detail X/Y [➙ see page 9]

Below second appliance

Depth > 555 mmAbove second appliance

Depth > 575 mmAbove warming drawer

Depth > 555 mm

W

X456

Y

50

≥ 40

W

450

X

Y

50

≥ 40

W

450

X

Y50

≥ 40

X = Height of second applianceY = Niche heightW = Angle set K20198

For an installation depth under 575 mm, it is recommended that the appliance be installed below other appliances for spacereasons.If installing with a second appliance in the same niche, use the angle set 60 W (K20198).

3

V-ZUG Ltd Planning aid J001.059-12Industriestrasse 66, P.O. Box 59, 6301 ZugTel. +41 58 767 67 67, Fax +41 58 767 61 61

Kitchen appliances03.09.14

[email protected], www.vzug.com

13

Page 14: Planning aid Kitchen appliances - V-ZUG AG · Kitchen appliances 03.09.14 info@vzug.com, 9. 2 Ovens 2.1 Electrical connection data Appliance Country group * Mains connection Fuse

Installation

≥ 40

≥ 40

≥ 40

3

V-ZUG Ltd Planning aid J001.059-12Industriestrasse 66, P.O. Box 59, 6301 ZugTel. +41 58 767 67 67, Fax +41 58 767 61 61

Kitchen appliances03.09.14

[email protected], www.vzug.com

14

Page 15: Planning aid Kitchen appliances - V-ZUG AG · Kitchen appliances 03.09.14 info@vzug.com, 9. 2 Ovens 2.1 Electrical connection data Appliance Country group * Mains connection Fuse

Plumbing in

1

4

2 73 56

≥ 5

0

70

0

1 Hose clamp2 Reinforced inlet hose 2 m, G ¾"3 Drain hose 3 m Inner diameter of connection 22 mm On-site installations4 Siphon5 Plinth panel6 Hose fed through plinth7 Cold water connection with stop-cock

OutletLength of drain hose 3 m

The hose loop must be mounted at a height of 700 mm (see illustration above).The drain hose may be neither lengthened nor shortened.The distance from the bottom of the appliance to the drain trap must be at least 50 mm.The drain hose must be laid flat without any kinks.

Cold water connection inletOperating pressure: 0.1-1.0 MPa (1-10 bar)

Only use if water hardness > 3 French degrees (> 1.7 German degrees) possible.

Length of reinforced hose: 2 m

Local water authority regulations must be observed.Existing hoses that are defective must be replaced.The reinforced hose may not be lengthened.The stop-cock must be accessible at all times.

3

V-ZUG Ltd Planning aid J001.059-12Industriestrasse 66, P.O. Box 59, 6301 ZugTel. +41 58 767 67 67, Fax +41 58 767 61 61

Kitchen appliances03.09.14

[email protected], www.vzug.com

15

Page 16: Planning aid Kitchen appliances - V-ZUG AG · Kitchen appliances 03.09.14 info@vzug.com, 9. 2 Ovens 2.1 Electrical connection data Appliance Country group * Mains connection Fuse

3.6 Combination possibilities

Combi-Steam SL, Steam S & oven

≥ 550

600

560–568

596 569

598

378

974

374

X

W

Y

≥ 550

600

560–568

974

594

596 569378

598

X

W

Y

Combi-Steam SL, Steam S & Hotair HSE, Combair HSE

≥ 550

600

560–568

596 569

378

378

754

374

X

W

Y

Combi-Steam XSL, Combair XSL, XSE & oven

≥ 550

600

560–568

596 569

598

454

1050

450

X

W

Y

Combi-Steam XSL & Combair XSL, XSE

≥ 550

600

560–568

596 569

45

44

54

90

6

45

0

X

W

Y

If installing with a second appliance in the same niche, use the angle set 60 W (K20198).

Front dimensions of the appliances: Detail X/Y [➙ see page 9]

3

V-ZUG Ltd Planning aid J001.059-12Industriestrasse 66, P.O. Box 59, 6301 ZugTel. +41 58 767 67 67, Fax +41 58 767 61 61

Kitchen appliances03.09.14

[email protected], www.vzug.com

16

Page 17: Planning aid Kitchen appliances - V-ZUG AG · Kitchen appliances 03.09.14 info@vzug.com, 9. 2 Ovens 2.1 Electrical connection data Appliance Country group * Mains connection Fuse

4 Coffee-CentersDepth of wall unit must be min. 480 mm.

4.1 Electrical connection data

Mains connection Fuse Mains cable230 V~ 50Hz 10 A 1.8 m, with plug

4.2 Supremo SL (75A)

600

550

374

560–568

X

596 412

378

480

Y

4.3 Supremo XSL (76A)

600

450

550

560-568

596 412

454

XX

480

Y

Front dimensions of the appliances: Detail X/Y [➙ see page 9]

4

V-ZUG Ltd Planning aid J001.059-12Industriestrasse 66, P.O. Box 59, 6301 ZugTel. +41 58 767 67 67, Fax +41 58 767 61 61

Kitchen appliances03.09.14

[email protected], www.vzug.com

17

Page 18: Planning aid Kitchen appliances - V-ZUG AG · Kitchen appliances 03.09.14 info@vzug.com, 9. 2 Ovens 2.1 Electrical connection data Appliance Country group * Mains connection Fuse

4.4 Combination possibilities

Supremo SL & oven Supremo SL & Hotair HSE, Combair HSE or steam cooker

596 569

≥ 550

600

560–568

598

974

374412

378

480

596 569

≥ 550

600

560–568

378

754

374 412

378

480

Supremo SL & Miwell SL Supremo XSL & compact oven or steam cooker

596 513

378

≥ 550

600

560–568

754

374412

378

480

596 569

≥ 550

600

560–568

906

450

X

454

412

454

480

Y

Front dimensions of the appliances: Detail X/Y [➙ see page 9]

4

V-ZUG Ltd Planning aid J001.059-12Industriestrasse 66, P.O. Box 59, 6301 ZugTel. +41 58 767 67 67, Fax +41 58 767 61 61

Kitchen appliances03.09.14

[email protected], www.vzug.com

18

Page 19: Planning aid Kitchen appliances - V-ZUG AG · Kitchen appliances 03.09.14 info@vzug.com, 9. 2 Ovens 2.1 Electrical connection data Appliance Country group * Mains connection Fuse

5 Warming and system drawers

5.1 General notes

Efficient repairs can only be guaranteed if it is possible to uninstall the whole appliance at any time without causing anydamage.

5.2 Electrical connection data

Plan a separate inlet for the electrical connection for each appliance, except for the «Combi connection». If connectedtogether, take the rated load into account.

General information on the electrical connections and an overview of the positions can be found in the Overview of connec-tions, ranges and dimensions [➙ see page 5] section.

Mains connection Fuse Mains cable Rated load230 V~ 50 Hz 10 A 1.7 m, with plug 810 W

5

V-ZUG Ltd Planning aid J001.059-12Industriestrasse 66, P.O. Box 59, 6301 ZugTel. +41 58 767 67 67, Fax +41 58 767 61 61

Kitchen appliances03.09.14

[email protected], www.vzug.com

19

Page 20: Planning aid Kitchen appliances - V-ZUG AG · Kitchen appliances 03.09.14 info@vzug.com, 9. 2 Ovens 2.1 Electrical connection data Appliance Country group * Mains connection Fuse

5.3 Warming drawers with niche width 60 cm

The angle mountings are not included in the scope of delivery. Order angle set K20198 at the same time.

WS 60/144 (34003)Built-in solo

144

560–568

596 547

142

600

≥ 550

Installing with compact oven or steam cooker Installing with oven & compact oven or steam cooker

454

142

596 547

567

600

560–568

594 4

50

X

≥ 550

Y

≥ 550

600

560–568

598

142

596 547

569

454

1194

450

X

600

Y

Front dimensions of the appliances: Detail X/Y [➙ see page 9]

5

V-ZUG Ltd Planning aid J001.059-12Industriestrasse 66, P.O. Box 59, 6301 ZugTel. +41 58 767 67 67, Fax +41 58 767 61 61

Kitchen appliances03.09.14

[email protected], www.vzug.com

20

Page 21: Planning aid Kitchen appliances - V-ZUG AG · Kitchen appliances 03.09.14 info@vzug.com, 9. 2 Ovens 2.1 Electrical connection data Appliance Country group * Mains connection Fuse

WS 60/162 (34004)Built-in solo Installing with an oven

162

560–568

596 547

160

600

≥ 550

598

160

596 547

600

560–568

756*

594**

X

567

≥ 550

Y

Installation height:* Niche height 762 mm** Height 600 mm

Installing with oven & mini oven or steam cooker

596 547

598

160

378

569

min. 550

600

560–568

1136

374

X

600

Y

Front dimensions of the appliances: Detail X/Y [➙ see page 9]

5

V-ZUG Ltd Planning aid J001.059-12Industriestrasse 66, P.O. Box 59, 6301 ZugTel. +41 58 767 67 67, Fax +41 58 767 61 61

Kitchen appliances03.09.14

[email protected], www.vzug.com

21

Page 22: Planning aid Kitchen appliances - V-ZUG AG · Kitchen appliances 03.09.14 info@vzug.com, 9. 2 Ovens 2.1 Electrical connection data Appliance Country group * Mains connection Fuse

WS 60/220 (34005)Built-in solo Installing with mini oven or steam cooker

220

560–568

596 547

218

600

≥ 550

378

218

596 547

600

560–568

594

374

X

567

≥ 550

Y

For niche height 635 mm -> Adapter frame, see section Accesso-ries [➙ see page 106]

WS 60/283 (34006)Built-in solo Installing with an oven

283

560–568

596 547

281

600

≥ 550

598

281

596 547

600

560–568

877

594

X

567

≥ 550

Y

Front dimensions of the appliances: Detail X/Y [➙ see page 9]

5

V-ZUG Ltd Planning aid J001.059-12Industriestrasse 66, P.O. Box 59, 6301 ZugTel. +41 58 767 67 67, Fax +41 58 767 61 61

Kitchen appliances03.09.14

[email protected], www.vzug.com

22

Page 23: Planning aid Kitchen appliances - V-ZUG AG · Kitchen appliances 03.09.14 info@vzug.com, 9. 2 Ovens 2.1 Electrical connection data Appliance Country group * Mains connection Fuse

5.4 System drawers with niche width 60 cm

SYS 60/144 (620)Installing with Supremo XSL

≥ 550

600

560–568

59

4

45

0

X

14

2

596 547

412

454

480

Y

SYS 60/76 (953)Installing with Supremo SL

600

≥ 550

560–568

450

374

X

74

596 560

412

378

Y

The telescopic runner for the assembly and operation is included in the scope of delivery.

Front dimensions of the appliances: Detail X/Y [➙ see page 9]

5

V-ZUG Ltd Planning aid J001.059-12Industriestrasse 66, P.O. Box 59, 6301 ZugTel. +41 58 767 67 67, Fax +41 58 767 61 61

Kitchen appliances03.09.14

[email protected], www.vzug.com

23

Page 24: Planning aid Kitchen appliances - V-ZUG AG · Kitchen appliances 03.09.14 info@vzug.com, 9. 2 Ovens 2.1 Electrical connection data Appliance Country group * Mains connection Fuse

6 Microwaves

Minimum installation height (child safety): Keep 850 mm distance from the floor to the bottom edge of the microwave!

The mounting angles are not included in the scope of delivery. Order angle set K20198 at the same time.

6.1 Electrical connection data

Type Mains connection Fuse Mains cableMiwell-Combi XSL 230 V~ 50 Hz 16 A 1.2 m, without plugMiwell-Combi SL,Miwell SL / L

230 V~ 50 Hz 10 A 1.2 m, with plug

6.2 Miwell-Combi SL (947), XSL (939), Miwell SL (945)

Miwell-Combi SL, Miwell SL Miwell-Combi XSL

378

596

T300

600

≥ 550

374 ¹

560-568

X

Y 454

596

567

600

450

560–568

X

350

Y

Appliance T Miwell-Combi SL 516 mm Miwell SL 470 mm

Front dimensions of the appliances: Detail X/Y [➙ see page 9]

6

V-ZUG Ltd Planning aid J001.059-12Industriestrasse 66, P.O. Box 59, 6301 ZugTel. +41 58 767 67 67, Fax +41 58 767 61 61

Kitchen appliances03.09.14

[email protected], www.vzug.com

24

Page 25: Planning aid Kitchen appliances - V-ZUG AG · Kitchen appliances 03.09.14 info@vzug.com, 9. 2 Ovens 2.1 Electrical connection data Appliance Country group * Mains connection Fuse

6.3 Miwell L (24002)

Door hinged left!

2050

==

600

381

762

596

378

320

≥ 330

560

6

V-ZUG Ltd Planning aid J001.059-12Industriestrasse 66, P.O. Box 59, 6301 ZugTel. +41 58 767 67 67, Fax +41 58 767 61 61

Kitchen appliances03.09.14

[email protected], www.vzug.com

25

Page 26: Planning aid Kitchen appliances - V-ZUG AG · Kitchen appliances 03.09.14 info@vzug.com, 9. 2 Ovens 2.1 Electrical connection data Appliance Country group * Mains connection Fuse

6.4 Combination possibilities

The mounting angles are not included in the scope of delivery. Order angle set K20198 at the same time.

Miwell-Combi SL & oven Miwell-Combi SL & mini oven or steam cooker

596 569

516

≥ 550

600

560–568

598

378

974

374

X

Y

596 569

516

≥ 550

600

560–568

378

378

754

374

X

Y

Miwell-Combi XSL & oven Miwell-Combi XSL & Combair XSL, XSE or Combi-

Steam XSL

600

560–568

596 569

59

8454

105

0

450

X

Y600

560–568

596 569

454

454

906

450

X

Y

Front dimensions of the appliances: Detail X/Y [➙ see page 9]

6

V-ZUG Ltd Planning aid J001.059-12Industriestrasse 66, P.O. Box 59, 6301 ZugTel. +41 58 767 67 67, Fax +41 58 767 61 61

Kitchen appliances03.09.14

[email protected], www.vzug.com

26

Page 27: Planning aid Kitchen appliances - V-ZUG AG · Kitchen appliances 03.09.14 info@vzug.com, 9. 2 Ovens 2.1 Electrical connection data Appliance Country group * Mains connection Fuse

Miwell S & oven

M

596 569

≥ 550

560-568

598

378

981

381

350

600

M assembly kit is included in the scope of delivery.

Door hinged left

6

V-ZUG Ltd Planning aid J001.059-12Industriestrasse 66, P.O. Box 59, 6301 ZugTel. +41 58 767 67 67, Fax +41 58 767 61 61

Kitchen appliances03.09.14

[email protected], www.vzug.com

27

Page 28: Planning aid Kitchen appliances - V-ZUG AG · Kitchen appliances 03.09.14 info@vzug.com, 9. 2 Ovens 2.1 Electrical connection data Appliance Country group * Mains connection Fuse

7 Glass ceramic hobs – induction, wok, teppanyaki

7.1 General notes

It is imperative for induction hobs to have adequate ventilation (see sections Installation without protective plate [➙ seepage 41] and Installation with protective plate [➙ see page 43]).This is guaranteed with a worktop depth of 20 mm to 40 mm.If a drawer is installed directly underneath, a protective plate is recommended in the vicinity of the mains cable and to protectthe ventilation openings. The protective plate set can be used (see Accessories [➙ see page 106]).With a front-facing air gap of 3 mm, a ventilation protective plate with seal is essential (Installation with protective plate [➙see page 43]).

Efficient repairs can only be guaranteed if it is possible to uninstall the whole appliance at any time without causing anydamage.

The layout of the hobs to be installed may differ from the hobs illustrated here!

Dear Customer

This planning aid contains the dimensions of all our current glass ceramic hobsSince April 2013, most of the flush induction hobs require larger cut-out dimensions and other corner radii. If you own an appliancewhich was manufactured before April 2013, please make sure that you do select the correct cut-out dimensions.The cut-out dimensions for flush induction hobs can be found in section Glass ceramic hobs for the replacement market [➙ seepage 53].

Our product range naturally still includes hobs which have the previous cut-out dimensions.

Thank you for reading this information.

Your V-ZUG Ltd

7

V-ZUG Ltd Planning aid J001.059-12Industriestrasse 66, P.O. Box 59, 6301 ZugTel. +41 58 767 67 67, Fax +41 58 767 61 61

Kitchen appliances03.09.14

[email protected], www.vzug.com

28

Page 29: Planning aid Kitchen appliances - V-ZUG AG · Kitchen appliances 03.09.14 info@vzug.com, 9. 2 Ovens 2.1 Electrical connection data Appliance Country group * Mains connection Fuse

7.2 Electrical connection data

Type Country Mains connection Fuse Mains cableGK16TIWS.1F,GK16TIYS.1F,GK26TIMS …

AU, CN, EU, GB, HK, IL,LB, NO, RU, SG, UA, TR

220-240 V~50/60 Hz16 A

1.7 m, without plugGK26TIYS.1F, GK36TI…,GK46TI…, GK46ID…,GK46IABD

EU, IL, LB, RU, UA, TR 380-415 V~ 2N 50/60 HzAU, CN, GB, HK, NO, SG 220-240 V~50/60 Hz 32 A

GK56TIMS … EU, IL, LB, NO, RU, UA,TR

380-415 V~ 3N 50/60 Hz 16 A

AU, CN, GB, HK, SG 220-240 V~50/60 Hz 48 A

7.3 Ventilation

In order to guarantee good ventilation, a space of≥ 17.5 mm height is necessary beneath the appli-ance.1. The back wall of the base unit must be open

in the area of the worktop cut-out to guar-antee continuous air circulation over theventilation slits.

2. Alternatively, air circulation inside the cabinetcan be provided for by a concealed fresh airintake.In order that enough cold air can be drawn in,there must be a continuous circulation offresh air that extends outside the cabinet.

≥ 15

21

7.4 Operation

Type Operating typeGK46ID…, GK46IABD… Dial controls according to J553.053

7

V-ZUG Ltd Planning aid J001.059-12Industriestrasse 66, P.O. Box 59, 6301 ZugTel. +41 58 767 67 67, Fax +41 58 767 61 61

Kitchen appliances03.09.14

[email protected], www.vzug.com

29

Page 30: Planning aid Kitchen appliances - V-ZUG AG · Kitchen appliances 03.09.14 info@vzug.com, 9. 2 Ovens 2.1 Electrical connection data Appliance Country group * Mains connection Fuse

7.5 Framed installation

Aim for corner radii of cut-out: ≤ 10 mm.Corner radii of appliance: 8 mm

GK26TIMS (84A) GK36TIS (008), GK36TISC (008), GK46TIMS (88A), GK46TIMSC (88A)

514

289

H

Y

Y

≥ 5

0

≥ 5

0

490

±1

600

265 ±1

A

275

Ri

Ra

490

±1

560 ±1

600

≥ 5

0

≥ 5

0

A

600

584

514

Y

Y

Ri

H

Ra

≥ 1

7.5

*

B

Y – Y

Drawer/Cabinet

* The clearance space must be provided!

Type ADepends on producer

B H Corner radiusRa/Ri

GK26TIMS ≥ 30 mm

≥ 65.2 mm 47.7 mm 10/8 mmGK36TIS, GK46TIMS

GK36TISC, GK46TIMSC ≥ 67.2 mm 49.7 mm

A Worktop depth (in combination with directly built-under oven)H Measurement from the top side of the worktop to the underside of the hob (ventilation opening)Ri Corner radii of applianceRa Outer corner radii of cut-out

7

V-ZUG Ltd Planning aid J001.059-12Industriestrasse 66, P.O. Box 59, 6301 ZugTel. +41 58 767 67 67, Fax +41 58 767 61 61

Kitchen appliances03.09.14

[email protected], www.vzug.com

30

Page 31: Planning aid Kitchen appliances - V-ZUG AG · Kitchen appliances 03.09.14 info@vzug.com, 9. 2 Ovens 2.1 Electrical connection data Appliance Country group * Mains connection Fuse

GK46IABD (96A), GK46IABDC (96A), GK46TIMAS (31030), GK46TIMASC (31030),

GK46TIABS (028), GK46TIABSC (028), GK46TIAKS (90A), GK46TIAKSC (90A)

GK36TIPS (975), GK36TIPSC (975)

514

H

774

Y

Y

490

±1

≥ 5

0

≥ 5

0

600

750 ±1

600

A

1

Ri

Ra

H

774

444

Y

Y

420

±1

≥ 5

0

≥ 5

0

750 ±1

600

A

Ri

Ra

≥ 1

7.5

*

B

Y – Y

Drawer/Cabinet

* The clearance space must be provided!

Type ADepends on producer

B H Corner radiusRa/Ri

GK46IABD, GK46TIMAS,GK46TIABS, GK46TIAKS

≥ 30 mm

≥ 64.0 mm 46.5 mm

10/8 mmGK36TIPS ≥ 65.2 mm 47.7 mmGK46IABDC, GK46TIMASC,GK46TIABSC, GK46TIAKSC,GK36TIPSC

≥ 66.0 mm 48.5 mm

A Worktop depth (in combination with directly built-under oven)H Measurement from the top side of the worktop to the underside of the hob (ventilation opening)Ri Corner radii of applianceRa Outer corner radii of cut-out1 For symmetrical installation, it is not necessary to cut out the side walls

7

V-ZUG Ltd Planning aid J001.059-12Industriestrasse 66, P.O. Box 59, 6301 ZugTel. +41 58 767 67 67, Fax +41 58 767 61 61

Kitchen appliances03.09.14

[email protected], www.vzug.com

31

Page 32: Planning aid Kitchen appliances - V-ZUG AG · Kitchen appliances 03.09.14 info@vzug.com, 9. 2 Ovens 2.1 Electrical connection data Appliance Country group * Mains connection Fuse

GK46ID (95A), GK46IDC (95A) GK46TIMXSC (31002)

490

±1

560 ±1

600

≥ 5

0

≥ 5

0

A

600

584

514

Y

Y

Ri

H

Ra

514

H

704

Y

Y

Ri

490

±1

≥ 5

0

≥ 5

0

A

600

680 ±1

600

=

=

=

=

1

Ra

92

600 42

±0.5

X

±0.5

≥ 103

≥ 38

5*

Fo

r ve

ntila

tio

n

x

≥ 1

7.5

*

B

Y – Y

Drawer/Cabinet

* The clearance space must be provided!

X = Ventilation slit 5 mm across the entire width of the unit, at least 25 cm².

Type ADepends on producer

B H Corner radiusRa/Ri

GK46ID ≥ 30 mm

≥ 65.2 mm 47.7 mm 10/8 mmGK46IDC ≥ 67.2 mm 49.7 mm

GK46TIMXSC ≥ 66.0 mm 48.5 mm

A Worktop depth (in combination with directly built-under oven)H Measurement from the top side of the worktop to the underside of the hob (ventilation opening)Ri Corner radii of applianceRa Outer corner radii of cut-out1 For symmetrical installation, it is not necessary to cut out the side walls

7

V-ZUG Ltd Planning aid J001.059-12Industriestrasse 66, P.O. Box 59, 6301 ZugTel. +41 58 767 67 67, Fax +41 58 767 61 61

Kitchen appliances03.09.14

[email protected], www.vzug.com

32

Page 33: Planning aid Kitchen appliances - V-ZUG AG · Kitchen appliances 03.09.14 info@vzug.com, 9. 2 Ovens 2.1 Electrical connection data Appliance Country group * Mains connection Fuse

GK46TIMPS (31029), GK46TIMPSC (31029), GK46TIPS (973), GK46TIPSC (973)

410

910

H

Y

Y

X

X

1

123

A

886 ±1386

±1

900

≥ 7

0

≥ 7

0

200

50

825

=

=

386

Ri

Ra

X – X

15

≥ 1

7.5

*

B

Drawer/

cabinet/

side panel

≥ 1

7.5

*

B

Y – Y

Drawer/Cabinet

* The clearance space must be provided!For niche width 900/825 mm, cut-outs in side walls left/right are necessary for the ventilation of the appliance. Keep blow-out opening free.

Type ADepends on producer

B H Corner radiusRa/Ri

GK46TIMPS ≥ 30 mm

≥ 64.5 mm 47.0 mm 10/8 mmGK46TIPS ≥ 62.8 mm 45.3 mm

GK46TIMPSC ≥ 67.2 mm 49.7 mmGK46TIPSC ≥ 65.5 mm 48.0 mm

A Worktop depth (in combination with directly built-under oven)H Measurement from the top side of the worktop to the underside of the hob (ventilation opening)Ri Corner radii of applianceRa Outer corner radii of cut-out1 Front and rear struts are reinforced on the underside. The strut width is determined by the producer of the stone

worktop. The minimum strut width can vary according to the property of the stone.2 For symmetrical installation, it is not necessary to cut out the side walls.

7

V-ZUG Ltd Planning aid J001.059-12Industriestrasse 66, P.O. Box 59, 6301 ZugTel. +41 58 767 67 67, Fax +41 58 767 61 61

Kitchen appliances03.09.14

[email protected], www.vzug.com

33

Page 34: Planning aid Kitchen appliances - V-ZUG AG · Kitchen appliances 03.09.14 info@vzug.com, 9. 2 Ovens 2.1 Electrical connection data Appliance Country group * Mains connection Fuse

GK56TIMS (89A), GK56TIMSC (89A)

514

910

H

900

A

600

886 ±1

≥ 5

0

490 ±

1

≥ 5

0

Y

Y

B

825

=

=

≥ 4

90

2

1

Ri

Ra

≥ 1

7.5

*

B

Y – Y

Drawer/Cabinet

* The clearance space must be provided!For niche width 900/825 mm, cut-outs in side walls left/right are necessary for the ventilation of the appliance. Keep blow-out opening free.

Type ADepends on producer

B H Corner radiusRa/Ri

GK56TIMS ≥ 30 mm ≥ 66.8 mm 49.3 mm 10/8 mmGK56TIMSC ≥ 68.8 mm 51.3 mm

A Worktop depth (in combination with directly built-under oven)H Measurement from the top side of the worktop to the underside of the hob (ventilation opening)Ri Corner radii of applianceRa Outer corner radii of cut-out1 For symmetrical installation, it is not necessary to cut out the side walls.2 Front and rear struts are reinforced on the underside. The strut width is determined by the producer of the stone

worktop. The minimum strut width can vary according to the property of the stone.

7

V-ZUG Ltd Planning aid J001.059-12Industriestrasse 66, P.O. Box 59, 6301 ZugTel. +41 58 767 67 67, Fax +41 58 767 61 61

Kitchen appliances03.09.14

[email protected], www.vzug.com

34

Page 35: Planning aid Kitchen appliances - V-ZUG AG · Kitchen appliances 03.09.14 info@vzug.com, 9. 2 Ovens 2.1 Electrical connection data Appliance Country group * Mains connection Fuse

7.6 Flush installation

Hob must be removable from below!

GK16TIWS.1F (31010) GK26TIMS.1F (31011)

H

384

501

390 ±1

≥ 4

1.5

≥ 4

1.5 600

507

±1

A

Z

600 ≥ 400

≥ 1

46

*

Ri

W

A

600

275

≥ 4

1.5

507 ±

1

≥ 4

1.5

Z

287 ±1

H

X

Ri 281

501

Y

Y

X

C D

Ra

R0–5

8.5 0

-1

8.5 0

-0.5

8.5

0/+

18.5

0/+

1

Steel angle bonded or screw mounted

Detail Z

H≥

17

.5 *

Y – Y

B

Drawer/Cabinet

Side wall

* The clearance space must be provided!

Type ADepends on producer

B C/D H Corner radiusRa/Ri

GK16TIWS.1F ≥ 30 mm ≥ 205 mm 373/490 mm 128.5 mm 5/1.5 mmGK26TIMS.1F ≥ 55 mm 270/490 mm 51.7 mm

A Worktop depth (in combination with directly built-under oven)B Necessary clearance space for service requirementsH Measurement from the top side of the worktop to the underside of the hob trayW The intermediate base must be removable from below.Ri Corner radii of appliance Ra Outer corner radii of cut-out

7

V-ZUG Ltd Planning aid J001.059-12Industriestrasse 66, P.O. Box 59, 6301 ZugTel. +41 58 767 67 67, Fax +41 58 767 61 61

Kitchen appliances03.09.14

[email protected], www.vzug.com

35

Page 36: Planning aid Kitchen appliances - V-ZUG AG · Kitchen appliances 03.09.14 info@vzug.com, 9. 2 Ovens 2.1 Electrical connection data Appliance Country group * Mains connection Fuse

GK16TIYS.1F (31008) GK26TIYS.1F (31009)

H

384

501

Y

Y

600 ≥ 400

≥ 4

1.5

600

≥ 4

1.5

Z

≥ 7

3.6

*

≥ 300

507 ±

1

390 ±1

A

Ri

for

ventila

tion

On both sides, for

technical reasons

501

571

H

Y

Y

600 A

Z

600

≥ 300

577 ±1

507±

1

Ri

73

.6 *

for

ve

ntila

tio

n

On both sides,

for technical

reasons

≥ 4

1.5

≥ 4

1.5

H≥

17

.5 *

Y – Y

B

Drawer/Cabinet

Side wall

C D

Ra

R0–5

8.5 0

-1

8.5 0

-0.5

8.5

0/+

18.5

0/+

1

Steel angle bonded or screw mounted

Detail Z

* The clearance space must be provided!

Type ADepends on producer

B C/D H Corner radiusRa/Ri

GK16TIYS.1F ≥ 30 mm ≥ 55 mm 373/490 mm 57.1 mm 5/1.5 mmGK26TIYS.1F 560/490 mm

A Worktop depth (in combination with directly built-under oven)B Necessary clearance space for service requirementsH Measurement from the top side of the worktop to the underside of the hob trayRi Corner radii of applianceRa Outer corner radii of cut-out

7

V-ZUG Ltd Planning aid J001.059-12Industriestrasse 66, P.O. Box 59, 6301 ZugTel. +41 58 767 67 67, Fax +41 58 767 61 61

Kitchen appliances03.09.14

[email protected], www.vzug.com

36

Page 37: Planning aid Kitchen appliances - V-ZUG AG · Kitchen appliances 03.09.14 info@vzug.com, 9. 2 Ovens 2.1 Electrical connection data Appliance Country group * Mains connection Fuse

GK26TIMS.2F (31001) GK36TIS.1F (31013), GK46ID.1F (31021),GK46TIMS.1F (31014)

600

501

384Ri

H

390 ±1

≥ 4

1.5

Z

600

507

±1

≥ 4

1.5

=

=

A

507

±1

577 ±1

600

≥ 4

1.5

≥ 4

1.5

A

600

571

501

Y

Y

Ri

Z

H

H≥

17

.5 *

Y – Y

B

Drawer/Cabinet

Side wall

C D

Ra

R0–5

8.5 0

-1

8.5 0

-0.5

8.5

0/+

18.5

0/+

1

Steel angle bonded or screw mounted

Detail Z

* The clearance space must be provided!

Type ADepends on producer

B C/D H Corner radiusRa/Ri

GK 26TIMS.2F ≥ 30 mm ≥ 55 mm 373/490 mm 51.7 mm 5/1.5 mmGK36TIS.1F, GK46ID.1F,GK46TIMS.1F

560/490 mm

A Worktop depth (in combination with directly built-under oven)B Necessary clearance space for service requirementsH Measurement from the top side of the worktop to the underside of the hob trayRi Corner radii of applianceRa Outer corner radii of cut-out

7

V-ZUG Ltd Planning aid J001.059-12Industriestrasse 66, P.O. Box 59, 6301 ZugTel. +41 58 767 67 67, Fax +41 58 767 61 61

Kitchen appliances03.09.14

[email protected], www.vzug.com

37

Page 38: Planning aid Kitchen appliances - V-ZUG AG · Kitchen appliances 03.09.14 info@vzug.com, 9. 2 Ovens 2.1 Electrical connection data Appliance Country group * Mains connection Fuse

GK46TIAKSF (90A), GK46TIMASF (31030),GK46TIABS.1F (31017), GK46IABD.1F (31022)

GK46TIMXSF (31002)

501

761Y

Y

507

±1

≥ 4

1.5

≥ 4

1.5

600

767 ±1

600

A

Z

Ri

H

501

691

Y

Y

A

507

±1

≥ 4

1.5

≥ 4

1.5

600

Z

697 ±1

600

Ri

H

H≥

17

.5 *

Y – Y

B

Drawer/Cabinet

Side wall

C D

Ra

R0–5

8.5 0

-1

8.5 0

-0.5

8.5

0/+

18.5

0/+

1

Steel angle bonded or screw mounted

Detail Z

* The clearance space must be provided!

Type ADepends on producer

B* C/D H Corner radiusRa/Ri

GK46TIMASF, GK46TIAKSF,GK46TIABS.1F, GK46IABD.1F

≥ 30 mm

≥ 55 mm

750/490 mm 50.5 mm 5/1.5 mm

GK46TIMXSF 680/490 mm 51.7 mm

A Worktop depth (in combination with directly built-under oven)B Necessary clearance space for service requirementsH Measurement from the top side of the worktop to the underside of the hob trayRi Corner radii of applianceRa Outer corner radii of cut-out

7

V-ZUG Ltd Planning aid J001.059-12Industriestrasse 66, P.O. Box 59, 6301 ZugTel. +41 58 767 67 67, Fax +41 58 767 61 61

Kitchen appliances03.09.14

[email protected], www.vzug.com

38

Page 39: Planning aid Kitchen appliances - V-ZUG AG · Kitchen appliances 03.09.14 info@vzug.com, 9. 2 Ovens 2.1 Electrical connection data Appliance Country group * Mains connection Fuse

GK36TIPSF (975) GK46TIPSF (973), GK46TIMPSF (31029)

H

744

414

Y

YX

X

420

±1

≥ 5

5

≥ 5

5

750 ±1

600

A

Z

Ri

380

880

H

W

W

2

123

A

886 ±1

≥ 7

0

386

±1

200

Z

≥ 7

0

900

82

825

=

=

≥ 4

56

1

Ri

C D

Ra

R0–5

8.5 0

-1

8.5 0

-0.5

8.5

0/+

18.5

0/+

1

Steel angle bonded or screw mounted

Detail Z

H≥

17

.5 *

Y – Y

B

Drawer/Cabinet

Side wall

B

≥ 1

7.5

*

600

H

X – X W - W

≥ 1

5

≥ 1

7.5

*

2

Drawer/Cabinet

* The clearance space must be provided!

Type ADepends on producer

B* C/D H Corner radiusRa/Ri

GK36TIPSF ≥ 30 mm

≥ 55 mm

733/403 mm 51.0 mm

5/1.5 mmGK46TIPSF,

GK46TIMPSF869/369 mm

A Worktop depth (in combination with directly built-under oven)B Necessary clearance space for service requirementsH Measurement from the top side of the worktop to the underside of the hob trayRi Corner radii of appliance Ra Outer corner radii of cut-out1 Front and rear struts are reinforced on the underside. The strut width is determined by the producer of the stone worktop. The

minimum strut width can vary according to the property of the stone.2 For niche width 900/825 mm, cut-outs in side walls left/right are necessary for the ventilation of the appliance. Keep blow-out

opening free.

7

V-ZUG Ltd Planning aid J001.059-12Industriestrasse 66, P.O. Box 59, 6301 ZugTel. +41 58 767 67 67, Fax +41 58 767 61 61

Kitchen appliances03.09.14

[email protected], www.vzug.com

39

Page 40: Planning aid Kitchen appliances - V-ZUG AG · Kitchen appliances 03.09.14 info@vzug.com, 9. 2 Ovens 2.1 Electrical connection data Appliance Country group * Mains connection Fuse

GK56TIMS.1F (31020)

501

897

H

900

A

600

903 ±1

≥ 5

0

507 ±

1

≥ 5

0

Y

Y

B

825

=

=

≥ 4

90

2

1

Ri

C D

Ra

R0–5

8.5 0

-1

8.5 0

-0.5

8.5

0/+

18.5

0/+

1

Steel angle bonded or screw mounted

Detail Z

H≥

17

.5 *

Y – Y

B

Drawer/Cabinet

Side wall

* The clearance space must be provided!

Type ADepends on producer

B C/D H Corner radiusRa/Ri

GK56TIMS.1F ≥ 30 mm ≥ 55 mm 886/490 mm 53.3 mm 5/1.5 mm

A Worktop depth (in combination with directly built-under oven)B Necessary clearance space for service requirementsH Measurement from the top side of the worktop to the underside of the hob trayRi Corner radii of appliance Ra Outer corner radii of cut-out1 For symmetrical installation, it is not necessary to cut out the side walls.2 Front and rear struts are reinforced on the underside. The strut width is determined by the producer of the stone worktop. The

minimum strut width can vary according to the property of the stone.

7

V-ZUG Ltd Planning aid J001.059-12Industriestrasse 66, P.O. Box 59, 6301 ZugTel. +41 58 767 67 67, Fax +41 58 767 61 61

Kitchen appliances03.09.14

[email protected], www.vzug.com

40

Page 41: Planning aid Kitchen appliances - V-ZUG AG · Kitchen appliances 03.09.14 info@vzug.com, 9. 2 Ovens 2.1 Electrical connection data Appliance Country group * Mains connection Fuse

7.7 Installation without protective plate

Requirements for optimal ventilation:

- a front-facing air gap of ≥ 5 mm

- a space of ≥ 17.5 mm in height beneath the appliance

- a worktop depth of ≥ 20 mm to ≤ 40 mm

- a supply of fresh air (≥ 15 mm air gap) is essential for the trouble-free operation of the hob.

GK26TI …, GK36TI …, GK46TI …

30

≥ 5

≥ 1

7.5

17.5

(50)

A ≥

67.5

≥ 15 600

Air gap over entire cabinet width ≥ 25 cm²

Necessary space below work surface for ventilation

Drawer Fan

GK46TIABS …, GK46TIAKS …

*C

≥ 5

5

600

GK56TIMS …

900

825 *C

≥ 5

5

bei N

ische 8

25

Ventilatoren

* Required for flush appliancesA Necessary space below the worktop for the ventilation of the applianceC Cut-out in side walls for disassembly from below, only for flush version

7

V-ZUG Ltd Planning aid J001.059-12Industriestrasse 66, P.O. Box 59, 6301 ZugTel. +41 58 767 67 67, Fax +41 58 767 61 61

Kitchen appliances03.09.14

[email protected], www.vzug.com

41

Page 42: Planning aid Kitchen appliances - V-ZUG AG · Kitchen appliances 03.09.14 info@vzug.com, 9. 2 Ovens 2.1 Electrical connection data Appliance Country group * Mains connection Fuse

GK46ID …, GK46IABD …

≥ 5

30

50

≥ 3

8≥

103

*C

≥ 5

5

≥ 15

600

92±0.5

42

±0

.5

92±0.5 92±0.5

Air gap entire

cabinet width ≥ 25 cm2

The intermediate bottom which is to prevent

accidental contact with live parts must be

removable by unscrewing from beneath.

Fan

Dial

GK46TIPS …, GK46TIMPS …

30

≥ 5

123 B ≥ 200

≥ 15825

900

≥ 1

7.5 1

7.5

*C

≥ 8

0

A ≥

67.5

B ≥

15

50

Ventilation

discharge

Ventilation

intake

A Necessary space below

work surface for ventilation

Ventilation

intake for

nic

he 8

25

Drawer

GK16TIYS.1F, GK26TIYS.1F

30

5

≥ 15 600 ≥ 1

7.5

56

.1

A ≥

73

.6

Drawer

Fan

A Necessary space below work surface for ventialtionAir gap over

entire width of cabinet element ≥ 25 cm²

* Required for flush appliancesA Necessary space below the worktop for the ventilation of the applianceB Cut-out in the side walls left and right for the ventilation of the applianceC Cut-out in the side walls for disassembly from below, only for flush version

7

V-ZUG Ltd Planning aid J001.059-12Industriestrasse 66, P.O. Box 59, 6301 ZugTel. +41 58 767 67 67, Fax +41 58 767 61 61

Kitchen appliances03.09.14

[email protected], www.vzug.com

42

Page 43: Planning aid Kitchen appliances - V-ZUG AG · Kitchen appliances 03.09.14 info@vzug.com, 9. 2 Ovens 2.1 Electrical connection data Appliance Country group * Mains connection Fuse

7.8 Installation with protective plate

For more information, see section Accessories [➙ see page 106].

Requirements for optimal ventilation:

- front-facing air gap of ≥ 3 mm (with protective plate)

- distance of ≥ 17.5 mm between protective plate and ventilation opening

- worktop depth of ≥ 20 mm to ≤ 40 mm

- a supply of fresh air (≥ 15 mm air gap) is essential for the trouble-free operation of the hob

A protective plate cannot be installed with induction hobs that have dial controls.

GK26TI …, GK36TI …, GK46TI …

55.5

≥ 3

5..10

≥ 15600

≥ 1

7.5

50

30

A ≥

67.5

≤ 0.5

56

ø4

393

Drawer

Fan

Well-fitting seal over width of cabinet element

Air gap over entire width of cabinet element ≥ 17 cm2

Ventilation protective plate

A Necessary space below

work surface for ventilation

GK46TIABS …, GK46TIAKS …, GK46TIMAS …

600

30

*C

≥ 5

5

* Required for flush appliancesA Necessary space below the worktop for the ventilation of the applianceC Cut-out in side walls for disassembly from below, only for flush version

7

V-ZUG Ltd Planning aid J001.059-12Industriestrasse 66, P.O. Box 59, 6301 ZugTel. +41 58 767 67 67, Fax +41 58 767 61 61

Kitchen appliances03.09.14

[email protected], www.vzug.com

43

Page 44: Planning aid Kitchen appliances - V-ZUG AG · Kitchen appliances 03.09.14 info@vzug.com, 9. 2 Ovens 2.1 Electrical connection data Appliance Country group * Mains connection Fuse

GK56TIMS …

30

*C

≥ 5

5

825

900

Fans

for

nic

he

82

5

GK46TIPS …, GK46TIMPS …

55.5

5..10

ø4

≥ 3

≥ 15

825

900

A ≥

67.5

B ≥

15

*C

≥ 8

2

≥ 1

7.5

(50)

30

≤ 0.5

123 B ≥ 200

56 393

Ventilation protective plate

for

nic

he 8

25

Drawer

Ventilation

intake

Ventilation

discharge

A Necessary space below

work surface for ventilation

Ventilationintake

GK16TIYS.1F, GK26TIYS.1F

61.6

≥ 3

5..10

≥ 15

600≥ 1

7.5

30

(56.1

)

*C

55

A ≥

73.6

≤ 0.5

56

ø4

393Drawer

Fan

Well-fitting seal over width of cabinet element

Air gap over entire width of cabinet element ≥ 17 cm2

Ventilation protective plate

A Necessary space below

work surface for ventilation

* Required for flush appliancesA Necessary space below the worktop for the ventilation of the applianceB Cut-out in the side walls left and right for the ventilation of the applianceC Cut-out in side walls for disassembly from below, only for flush version

7

V-ZUG Ltd Planning aid J001.059-12Industriestrasse 66, P.O. Box 59, 6301 ZugTel. +41 58 767 67 67, Fax +41 58 767 61 61

Kitchen appliances03.09.14

[email protected], www.vzug.com

44

Page 45: Planning aid Kitchen appliances - V-ZUG AG · Kitchen appliances 03.09.14 info@vzug.com, 9. 2 Ovens 2.1 Electrical connection data Appliance Country group * Mains connection Fuse

7.9 Installing above oven / steam cooker

It is not possible to install an oven below the following hobs: GK46TIMPS…, GK46TIPS…, GK56TIMS…, GK26ID…,GK46ID…, GK46IABD…

With the use of a ventilation grille (Accessories [➙ see page 106])Type of construction 60-381: Combi-Steam SL, Steam S, Hotair HSEType of construction 60-450: Combi-Steam XSL, Combair XSL, Combair XSEType of construction 60-600: Combair-Steam S, Combair-Steam N, Combair SLP, Combair SL, Combair SEP, Combair SE

Y

Cvar.

≥ 15

≤ 3

0

≥ 2

0

D3

BE

A

AA

A

= =

600

~230

35

C

5–6

≥ 2

0

3D

≤ 5

0

E

≥ 6

7,5

Ventilation grille

(see «Accessories»)

Cut-out in the rear

panel, if required

Detail Y

A Possible mains supply connectionsB Mounting cut-outsC Appliance height: 59.8 cm (type of construction: 60-600), 37.8 cm (type of construction: 60-381), 45.4 cm (type of construc-

tion: 60-450)D Niche height: 63.5 cm (type of construction: 60-600), 41.6 cm (type of construction: 60-381), 45.0 cm (type of construction:

60-450)E Cut-outs in side walls for hobs larger than niche width

7

V-ZUG Ltd Planning aid J001.059-12Industriestrasse 66, P.O. Box 59, 6301 ZugTel. +41 58 767 67 67, Fax +41 58 767 61 61

Kitchen appliances03.09.14

[email protected], www.vzug.com

45

Page 46: Planning aid Kitchen appliances - V-ZUG AG · Kitchen appliances 03.09.14 info@vzug.com, 9. 2 Ovens 2.1 Electrical connection data Appliance Country group * Mains connection Fuse

8 Toptronic glass ceramic hobs

8.1 General notes

The distance between the underside of the hob tray and any part of the cabinet beneath that is made of combustible materialmust be ≥ 20 mm. The distance from the hob cut-out to flammable walls (left, right and rear) must be ≥ 50 mm, for flushmounted ≥ 41.5 mm, for GK45TEPSF ≥ 55 mm.If a drawer is installed directly underneath – and if the tray can be reached from below without the aid of tools – a guardmust be used. The protective plate-set (see Accessories [➙ see page 106]) is recommended.

Efficient repairs can only be guaranteed if it is possible to uninstall the whole appliance at any time without causing anydamage.

The layout of the hobs to be installed may differ from the hobs illustrated here!

Dear Customer

This planning aid contains the dimensions of all our current glass ceramic hobs.

Since April 2013, most of the flush Toptronic hobs require larger cut-out dimensions and other corner radii. If you own an appliancewhich was manufactured before April 2013, please make sure that you do select the correct cut-out dimensions.You will find the cut-out dimensions for flush Toptronic hobs in the section Glass ceramic hobs for the replacement market [➙ seepage 53].

Our product range naturally still includes hobs which have the previous cut-out dimensions.

Thank you for reading this information

Your V-ZUG Ltd

8.2 Electrical connection data

General information on the electrical connections and an overview of the positions can be found in section Overview ofconnections, ranges and dimensions [➙ see page 5].

Type Mains connection Fuse Mains cable CountryGK25TE …

220-240 V~ 50 Hz

16 A

1.7 m, without plug

CNGK45TEBS …GK35TEPS …,GK45TEAS …,GK45TEPS …

32 A AU, CN, GB, HK, NO, SG

GK45TEBS …GK35TEPS …,GK45TEAS …,GK45TEPS …

380–415 V~ 2N 50 Hz 16 A EU, IL LB, RU, UA TR

8

V-ZUG Ltd Planning aid J001.059-12Industriestrasse 66, P.O. Box 59, 6301 ZugTel. +41 58 767 67 67, Fax +41 58 767 61 61

Kitchen appliances03.09.14

[email protected], www.vzug.com

46

Page 47: Planning aid Kitchen appliances - V-ZUG AG · Kitchen appliances 03.09.14 info@vzug.com, 9. 2 Ovens 2.1 Electrical connection data Appliance Country group * Mains connection Fuse

8.3 Framed installation

A width of 600 mm is recommended for the base unit.

- «Click-in» assembly- Outer corner radii of cut-out, aim for ≤ 10 mm- Corner radii of appliance 8 mm

GK25TE (005)

≥ 50

≥ 50

490 ±

1

600

265 ±1

A275

Y

Y

289

514

81

H

Self-tapping screws

Ri

Ra

H≥

20 *

Y – Y

Drawer/Cabinet

* The clearance space must be provided!

Type ADepends on producer

H

GK25TE ≥ 30 mm 39.2 mm

A Worktop depth (in combination with directly built-under oven)H Measurement from the top side of the worktop to the underside of the hob tray1 Thermal shielding plate set Accessories [➙ see page 106]

8

V-ZUG Ltd Planning aid J001.059-12Industriestrasse 66, P.O. Box 59, 6301 ZugTel. +41 58 767 67 67, Fax +41 58 767 61 61

Kitchen appliances03.09.14

[email protected], www.vzug.com

47

Page 48: Planning aid Kitchen appliances - V-ZUG AG · Kitchen appliances 03.09.14 info@vzug.com, 9. 2 Ovens 2.1 Electrical connection data Appliance Country group * Mains connection Fuse

GK45TEAS (977), GK45TEASC (977) GK45TEBS.1 (032), GK45TEBS.1C (032)

B60

0

A

490 ±

1

≥ 50

≥ 50

750 ±1

600

81

H

774

514

Y

YX

X

Self-tapping screws

600

600

560 ±1

490 ±

1

≥ 50

≥ 50

A

H

584

514

1

8

X

X

Self-tapping screws

H≥

20

*

Y – Y

Drawer/Cabinet

* The clearance space must be provided!

Type ADepends on producer

B H

GK45TEAS, GK45TEASC ≥ 30 mm 65.2 mm 45.2 mmGK45TEBS.1, GK45TEBS.1C 66.5 mm 46.5 mm

A Worktop depth (in combination with directly built-under oven)B Cut-out in side walls (with/without thermal shielding plate set)H Measurement from the top side of the worktop to the underside of the hob tray1 Thermal shielding plate set Accessories [➙ see page 106]

8

V-ZUG Ltd Planning aid J001.059-12Industriestrasse 66, P.O. Box 59, 6301 ZugTel. +41 58 767 67 67, Fax +41 58 767 61 61

Kitchen appliances03.09.14

[email protected], www.vzug.com

48

Page 49: Planning aid Kitchen appliances - V-ZUG AG · Kitchen appliances 03.09.14 info@vzug.com, 9. 2 Ovens 2.1 Electrical connection data Appliance Country group * Mains connection Fuse

GK35TEPS (31032), GK35TEPSC (31032) GK45TEPS (976), GK45TEPSC (976)

8

774

444

H

Y

Y

420

±1

≥ 50

≥ 50

750 ±1

600

B

600

A

Z

Z

1

Self-tapping screws

A

886 ±1

386 ±

1

900/825≥ 7

0

≥ 7

0

Y

Y

910

8

1

410

2

X

X

Self-tapping screws

Y – Y

≥ 2

0 *

B

Drawer/Cabinet

B

825±1

≥ 20 *

Z – Z

H

Drawer/

Cabinet

Side wall

* The clearance space must be provided!

Type ADepends on producer

B H

GK35TEPS, GK45TEPS ≥ 25 mm ≥ 63.5 mm 43.5 mmGK35TEPSC, GK45TEPSC ≥ 30 mm ≥ 66.5 mm 46.5 mm

A Worktop depth (in combination with directly built-under oven)B Cut-out in side walls (with/without thermal shielding plate set)H Measurement from the top side of the worktop to the underside of the hob tray1 Front and rear struts are reinforced on the underside. The strut width is determined by the producer of the stone

worktop. The minimum strut width can vary according to the property of the stone.2 Thermal shielding plate set Accessories [➙ see page 106]

8

V-ZUG Ltd Planning aid J001.059-12Industriestrasse 66, P.O. Box 59, 6301 ZugTel. +41 58 767 67 67, Fax +41 58 767 61 61

Kitchen appliances03.09.14

[email protected], www.vzug.com

49

Page 50: Planning aid Kitchen appliances - V-ZUG AG · Kitchen appliances 03.09.14 info@vzug.com, 9. 2 Ovens 2.1 Electrical connection data Appliance Country group * Mains connection Fuse

8.4 Flush installation

If a drawer is installed directly underneath – and if the tray can be reached from below without the aid of tools – an inter-mediate base must be used.

A width of 600 mm is recommended for the base unit.Access to the hob from below must be guaranteed. For servicing, the hob control unit can be exchanged from below.

GK25TE.1F (31023)

≥ 4

1.5

≥ 4

1.5 600

275

A

507 ±

1

287 ±1Z

Y

Y

501

X

H

Ri 281

X

C D

Ra

R0–5

8.5 0-1

8.5 0-0.5

Detail Z

8.5

0/+

18.5

0/+

1

Steel angle bonded

or screw mounted

X – X

≥ 2

0 *

275/500

B

H

Side wall

Drawer/Cabinet

Y – Y

H≥

20 *

B

Side wall

Drawer/Cabinet

* The clearance space must be provided!

Type ADepends on producer

B C/D H Corner radiusRa/Ri

GK25TE.1F ≥ 30 mm ≥ 82 mm 270/490 mm 47.5 mm 5/1.5 mm

A Worktop depth (in combination with directly built-under oven)B Minimum measurement in side wall area for disassembly of hob trayH Measurement from the top side of the worktop to the underside of the hob trayRi Corner radii of applianceRa Outer corner radii of cut-out

8

V-ZUG Ltd Planning aid J001.059-12Industriestrasse 66, P.O. Box 59, 6301 ZugTel. +41 58 767 67 67, Fax +41 58 767 61 61

Kitchen appliances03.09.14

[email protected], www.vzug.com

50

Page 51: Planning aid Kitchen appliances - V-ZUG AG · Kitchen appliances 03.09.14 info@vzug.com, 9. 2 Ovens 2.1 Electrical connection data Appliance Country group * Mains connection Fuse

GK45TEAS.1F (31026) GK45TEBS.2F (31028)

761

501

H

Y

Y

Ri507

±1

≥ 4

1.5

≥ 4

1.5

767 ±1

600

Z

600

A

B

X

X

571

501

600

577 ±1

507

±1

≥ 4

1.5

≥ 4

1.5

Z

600

A

H

Ri

C D

Ra

R0–5

8.5 0-1

8.5 0-0.5

Detail Z

8.5

0/+

18.5

0/+

1

Steel angle bonded

or screw mounted

X – X

≥ 2

0 *

275/500

B

H

Side wall

Drawer/Cabinet

Y – Y

H≥

20 *

B

Side wall

Drawer/Cabinet

* The clearance space must be provided!

Type ADepends on producer

B C/D H Corner radiusRa/Ri

GK45TEAS.1F ≥ 30 mm ≥ 82 mm 750/490 mm 47.5 mm 5/1.5 mmGK45TEBS.2F 560/490 mm

A Worktop depth (in combination with directly built-under oven)B Minimum measurement in side wall area for disassembly of hob trayH Measurement from the top side of the worktop to the underside of the hob trayRi Corner radii of applianceRa Outer corner radii of cut-out

8

V-ZUG Ltd Planning aid J001.059-12Industriestrasse 66, P.O. Box 59, 6301 ZugTel. +41 58 767 67 67, Fax +41 58 767 61 61

Kitchen appliances03.09.14

[email protected], www.vzug.com

51

Page 52: Planning aid Kitchen appliances - V-ZUG AG · Kitchen appliances 03.09.14 info@vzug.com, 9. 2 Ovens 2.1 Electrical connection data Appliance Country group * Mains connection Fuse

GK35TEPSF (31032) GK45TEPSF (976)

744

414

H420

±1

≥ 4

1.5

≥ 4

1.5

750 ±1

600

A

B≥ 5

30

Z

YY

Ri

A

886 ±1

386

±1

900/825

Z

≥ 7

0

≥ 7

0

1

YY

380

880

Ri

H

C D

Ra

R0–5

8.5 0-1

8.5 0-0.5

Detail Z

8.5

0/+

18.5

0/+

1

Steel angle bonded

or screw mounted

B

825≥ 20 *

Y – Y

H

Drawer/Cabinet

Side wall

* The clearance space must be provided!

Type ADepends on producer

B C/D H Corner radiusRa/Ri

GK35TEPSF ≥ 30 mm ≥ 82 mm 733/403 mm 47.5 mm 5/1.5 mmGK45TEPSF 869/369 mm

A Worktop depth (in combination with directly built-under oven)B Minimum measurement in side wall area for disassembly of hob trayH Measurement from the top side of the worktop to the underside of the hob trayRi Corner radii of applianceRa Outer corner radii of cut-out1 Front and rear struts are reinforced on the underside. The strut width is determined by the producer of the

stone worktop. The minimum strut width can vary according to the property of the stone.

8

V-ZUG Ltd Planning aid J001.059-12Industriestrasse 66, P.O. Box 59, 6301 ZugTel. +41 58 767 67 67, Fax +41 58 767 61 61

Kitchen appliances03.09.14

[email protected], www.vzug.com

52

Page 53: Planning aid Kitchen appliances - V-ZUG AG · Kitchen appliances 03.09.14 info@vzug.com, 9. 2 Ovens 2.1 Electrical connection data Appliance Country group * Mains connection Fuse

9 Glass ceramic hobs for the replacement market

9.1 Appliances for the replacement market – induction

For general notes, electrical connection data and how to operate the appliance, see section Glass ceramic hobs – induc-tion, wok, teppanyaki [➙ see page 28].Hob must be removable from below!

Corner radii of appliance 11 mm

GK16TIWSF (87A)

H

384

477

390 ±1

≥ 5

5

≥ 5

5

600

483

±1

A

Z

600 ≥ 400

≥ 1

46 *

Ri

1

C D

Ra

R0–5

8.5 0

-1

8.5 0

-0.5

8.5

0/+

18.5

0/+

1

Steel angle bonded or screw mounted

Detail Z

* The clearance space must be provided!

Type ADepends on producer

C/D H Corner radiusRa/Ri

GK16TIWSF ≥ 30 mm 373/466 mm 128.5 mm 14/11 mm

A Worktop depth (in combination with directly built-under oven)B Necessary clearance space for service requirementsH Measurement from the top side of the worktop to the underside of the hob (ventilation openings)Ri Corner radii of applianceRa Outer corner radii of cut-out1 The intermediate base must be removable from below.

9

V-ZUG Ltd Planning aid J001.059-12Industriestrasse 66, P.O. Box 59, 6301 ZugTel. +41 58 767 67 67, Fax +41 58 767 61 61

Kitchen appliances03.09.14

[email protected], www.vzug.com

53

Page 54: Planning aid Kitchen appliances - V-ZUG AG · Kitchen appliances 03.09.14 info@vzug.com, 9. 2 Ovens 2.1 Electrical connection data Appliance Country group * Mains connection Fuse

GK16TIYSF (85A) GK26TIYSF (86A)

H

384

477

Y

Y

600 ≥ 400

≥ 5

5600

≥ 5

5

Z ≥

73

.6 *

≥ 300

483

±1

390 ±1

A

Ri

for

ve

ntila

tio

n

On both sides

for technical

reasons

477

547

H

Y

Y

600 A

Z

≥ 5

5

600

≥ 5

5

≥ 300

553 ±1

483

±1

Ri

On both sides

for technical

reasons

for

ventila

tion

73.6

*

Y – Y

H≥

17.5

*

B

Drawer/Cabinet

Side wall

C D

Ra

R0–5

8.5 0

-1

8.5 0

-0.5

8.5

0/+

18.5

0/+

1

Steel angle bonded or screw mounted

Detail Z

* The clearance space must be provided!

Type ADepends on producer

B C/D H Corner radiusRa/Ri

GK16TIYSF ≥ 30 mm ≥ 55 mm 373/466 mm 57.1 mm 14/11 mmGK26TIYSF 536/466 mm

A Worktop depth (in combination with directly built-under oven)B Necessary clearance space for service requirementsH Measurement from the top side of the worktop to the underside of the hob (ventilation openings)Ri Corner radii of applianceRa Outer corner radii of cut-out

9

V-ZUG Ltd Planning aid J001.059-12Industriestrasse 66, P.O. Box 59, 6301 ZugTel. +41 58 767 67 67, Fax +41 58 767 61 61

Kitchen appliances03.09.14

[email protected], www.vzug.com

54

Page 55: Planning aid Kitchen appliances - V-ZUG AG · Kitchen appliances 03.09.14 info@vzug.com, 9. 2 Ovens 2.1 Electrical connection data Appliance Country group * Mains connection Fuse

GK26TIMSF (84A) GK36TISF (008)

477

272

Y

Y≥ 55

≥ 55

483 ±1

600278±1

A275

Ri

H

Z

483

±1

553 ±1

600

≥ 5

5

≥ 5

5

A

600

547

477

Y

Y

Ri

Z

H

Y – Y

H≥

17.5

*

B

Drawer/Cabinet

Side wall

C D

Ra

R0–5

8.5 0

-1

8.5 0

-0.5

8.5

0/+

18.5

0/+

1

Steel angle bonded or screw mounted

Detail Z

* The clearance space must be provided!

Type ADepends on producer

B C/D H Corner radiusRa/Ri

GK26TIMSF ≥ 30 mm ≥ 55 mm 261/466 mm 50.0 mm 14/11 mmGK36TISF 536/466 mm 51.7 mm

A Worktop depth (in combination with directly built-under oven)B Necessary clearance space for service requirementsH Measurement from the top side of the worktop to the underside of the hob (ventilation openings)Ri Corner radii of applianceRa Outer corner radii of cut-out

9

V-ZUG Ltd Planning aid J001.059-12Industriestrasse 66, P.O. Box 59, 6301 ZugTel. +41 58 767 67 67, Fax +41 58 767 61 61

Kitchen appliances03.09.14

[email protected], www.vzug.com

55

Page 56: Planning aid Kitchen appliances - V-ZUG AG · Kitchen appliances 03.09.14 info@vzug.com, 9. 2 Ovens 2.1 Electrical connection data Appliance Country group * Mains connection Fuse

GK46IDF (95A), GK46TIMSF (88A) GK46IABDF (96A), GK46TIABSF (028)

483

±1

553 ±1

600

≥ 5

5

≥ 5

5

A

600

547

477

Y

Y

Ri

Z

H

483

±1

≥ 5

5

≥ 5

5

600

743 ±1

600

A

Z

477

737Y

Y

Ri

1

H

Y – Y

H≥

17.5

*

B

Drawer/Cabinet

Side wall

C D

Ra

R0–5

8.5 0

-1

8.5 0

-0.5

8.5

0/+

18.5

0/+

1

Steel angle bonded or screw mounted

Detail Z

* The clearance space must be provided!

Type ADepends on producer

B C/D H Corner radiusRa/Ri

GK46IDF, GK46TIMSF ≥ 30 mm ≥ 55 mm 536/466 mm 51.7 mm 14/11 mmGK46IABDF, GK46TIABSF 726/466 mm 50.0 mm

A Worktop depth (in combination with directly built-under oven)B Necessary clearance space for service requirementsH Measurement from the top side of the worktop to the underside of the hob (ventilation openings)Ri Corner radii of applianceRa Outer corner radii of cut-out1 For symmetrical installation, it is not necessary to cut out the side walls.

9

V-ZUG Ltd Planning aid J001.059-12Industriestrasse 66, P.O. Box 59, 6301 ZugTel. +41 58 767 67 67, Fax +41 58 767 61 61

Kitchen appliances03.09.14

[email protected], www.vzug.com

56

Page 57: Planning aid Kitchen appliances - V-ZUG AG · Kitchen appliances 03.09.14 info@vzug.com, 9. 2 Ovens 2.1 Electrical connection data Appliance Country group * Mains connection Fuse

GK56TIMSF (89A)

477

880

H

900

600

886 ±1

≥ 5

5

483

±1

≥ 5

5

Z1

B

825

=

=

≥ 5

38

2

Ri Y – Y

H≥

17.5

*

B

Drawer/Cabinet

Side wall

C D

Ra

R0–5

8.5 0

-1

8.5 0

-0.5

8.5

0/+

18.5

0/+

1

Steel angle bonded or screw mounted

Detail Z

* The clearance space must be provided!

Type ADepends on producer

B C/D H Corner radiusRa/Ri

GK56TIMSF ≥ 30 mm ≥ 55 mm 869/466 mm 53.3 mm 5/1.5 mm

A Worktop depth (in combination with directly built-under oven)B Necessary clearance space for service requirementsH Measurement from the top side of the worktop to the underside of the hob (ventilation openings)Ri Corner radii of applianceRa Outer corner radii of cut-out1 For symmetrical installation, it is not necessary to cut out the side walls2 Front and rear struts are reinforced on the underside. The strut width is determined by the producer of the stone

worktop. The minimum strut width can vary according to the property of the stone.

9

V-ZUG Ltd Planning aid J001.059-12Industriestrasse 66, P.O. Box 59, 6301 ZugTel. +41 58 767 67 67, Fax +41 58 767 61 61

Kitchen appliances03.09.14

[email protected], www.vzug.com

57

Page 58: Planning aid Kitchen appliances - V-ZUG AG · Kitchen appliances 03.09.14 info@vzug.com, 9. 2 Ovens 2.1 Electrical connection data Appliance Country group * Mains connection Fuse

9.2 Appliances for the replacement market – Toptronic

For general notes, electrical connection data and how to operate the appliance, see section Toptronic glass ceramic hobs[➙ see page 46].If a drawer is installed directly underneath – and if the tray can be reached from below without the aid of tools – an inter-mediate base must be used.

A width of 600 mm is recommended for the base unit.Access to the hob from below must be guaranteed. For servicing, the hob control unit can be exchanged from below.Corner radii of appliance 11 mm

GK45TEBS.1F (032) GK45TEASF (977)

547

477X

X

600

553 ±1

483

±1

≥ 5

5

≥ 5

5

Z

600

A

H

Ri

737

X

X

477

483

±1

≥ 5

5

≥ 5

5

743 ±1

600

Z

600

A

B

H

Ri

X–X

H≥

20 *

B

Side wall

Drawer/CabinetC D

Ra

R0–5

8.5 0-1

8.5 0-0.5

Detail Z

8.5

0/+

18.5

0/+

1

Steel angle bonded

or screw mounted

* The clearance space must be provided!

Type ADepends on producer

B C/D H Corner radiusRa/Ri

GK45TEBS.1F ≥ 30 mm ≥ 82 mm 536/466 mm 47.5 mm 14/11 mmGK45TEASF 726/466 mm

A Worktop depth (in combination with directly built-under oven)B Minimum measurement in side wall area for disassembly of hob trayH Measurement from the top side of the worktop to the underside of the hob trayRi Corner radii of appliance Ra Outer corner radii of cut-out

9

V-ZUG Ltd Planning aid J001.059-12Industriestrasse 66, P.O. Box 59, 6301 ZugTel. +41 58 767 67 67, Fax +41 58 767 61 61

Kitchen appliances03.09.14

[email protected], www.vzug.com

58

Page 59: Planning aid Kitchen appliances - V-ZUG AG · Kitchen appliances 03.09.14 info@vzug.com, 9. 2 Ovens 2.1 Electrical connection data Appliance Country group * Mains connection Fuse

10 Examples for combined appliance installation

Size B A ± 1

30 + 40 388.5 674 ± 1 30 + 60 575.5 861 ± 1

Size B A ± 1

40 + 40 388.5 777 ± 1 40 + 60 575.5 964 ± 1

Size B A ± 1

30 + 40 + 40 387 1061 ± 1 30 + 60 + 40 574 1248 ± 1

Size B A ± 1

40 + 40 + 40 387 1164 ± 1 40 + 60 + 40 574 1351 ± 1

Y-Y

Intermediate supportset H63789

281

B

3

285.5

A ±1

384

B

3

388.5

A±1

281

B

384 3

3

285.5

388.5

A±1

384

384

B

3

3

388.5

388.5

501

≥ 600 507±1

≥ 41.5

≥ 41.5

501

507±1

≥ 41.5

≥ 41.5 ≥ 600

501

507±1

≥ 600

≥ 41.5

≥ 41.5

501

507±1

≥ 600

≥ 41.5

≥ 41.5

A±1

≥ 41.5

8.5 0

-1

Y

Y

X

X

H

X-X

Type

Standard

H

GK16TIWSF, GK16TIWS.1F

6.5 mm

7.7 mm

Cementing-in instructions J402.80

8.5

0 -1

10

V-ZUG Ltd Planning aid J001.059-12Industriestrasse 66, P.O. Box 59, 6301 ZugTel. +41 58 767 67 67, Fax +41 58 767 61 61

Kitchen appliances03.09.14

[email protected], www.vzug.com

59

Page 60: Planning aid Kitchen appliances - V-ZUG AG · Kitchen appliances 03.09.14 info@vzug.com, 9. 2 Ovens 2.1 Electrical connection data Appliance Country group * Mains connection Fuse

11 Gas hobs & lava grills

11.1 Gas hobs

When a range hood is installed above the gas hob, a minimum distance of 750 mm must be observed.

≥ 750

≥ 450

≥ 5

GK11TG, GK11TTG

520

45

57

62

44

43

≥ 50

≥ 100*≥ 600

≥ 3

0

270+2

490-

500+2

302

80

≥ 9

5

87

≥ 5

≥ 25

10

–1

5050

30

–5

0

* Minimum distance from mounting cut-out to the wall

** Position of gas connection in cut-out

Designation Art. no. Mains connec-tion

Fuse Rated load Gas type Connectioncable

Country

GK11TG 798.3.49 220-240 V~50/60 Hz

3 A 1 W Natural gas H/E/(L)20 (25) mbar

1 m, without plug RU/UA, UK, LB,HK, SG, TR, IT

798.3.69 Natural gas 1 kPa 1 m, AU plug AUGK11TTG 851.3.89 Town gas G110

8 mbar1 m, BS plug HK, SG

11

V-ZUG Ltd Planning aid J001.059-12Industriestrasse 66, P.O. Box 59, 6301 ZugTel. +41 58 767 67 67, Fax +41 58 767 61 61

Kitchen appliances03.09.14

[email protected], www.vzug.com

60

Page 61: Planning aid Kitchen appliances - V-ZUG AG · Kitchen appliances 03.09.14 info@vzug.com, 9. 2 Ovens 2.1 Electrical connection data Appliance Country group * Mains connection Fuse

GK21TG, GK21TTG

520

302

47

62

44

43

≥ 50

≥ 3

0≥ 600490-

500+2

270+2

≥ 100*

45

≤ 1

50

≥ 1

0 ≥ 25

45

30-5

0

62

≥ 8

0 ≥ 5

GK1121TGCN

520

45

57

62

44

43

≥ 50

≥ 100*

≥ 600

≥ 3

0

576+2

490-

500+2

604

Connection strip

1 × H64140

80

≥ 9

5

87

≥ 5

≥ 25

10–15050

30–50

≤ 1

50

≥ 1

0 ≥ 25

45

30-5

0

62

≥ 8

0 ≥ 5

* Minimum distance from mounting cut-out to the wall

** Position of gas connection in cut-out

Designation Art. no. Mainsconnec-

tion

Fuse Rated load Gas type Connectioncable

Country

GK21TG 797.3.49 220-240 V~50/60 Hz 3 A 1 W

Natural gasH/E/(L)

20 (25) mbar

1 m, without plug RU/UA, UK, LB,HK, SG, TR, IT

GK21TTG 302.3.89 Town gas G1108 mbar

SG, HK

GK1121TGCN 31035.67.200 220 V~50 Hz

Natural gasH/E/(L)

20 (25) mbar

2 × 1 m, 2 × CN plug

CN

11

V-ZUG Ltd Planning aid J001.059-12Industriestrasse 66, P.O. Box 59, 6301 ZugTel. +41 58 767 67 67, Fax +41 58 767 61 61

Kitchen appliances03.09.14

[email protected], www.vzug.com

61

Page 62: Planning aid Kitchen appliances - V-ZUG AG · Kitchen appliances 03.09.14 info@vzug.com, 9. 2 Ovens 2.1 Electrical connection data Appliance Country group * Mains connection Fuse

GK41TG

602

520

45

47

53

≥ 50≥

30≥ 600

26

21

≥ 100*490

±1560±1

≤ 1

50

≥ 1

0

≥ 25

45

30-5

0

50

≥ 8

0 ≥ 5

35

GK51TPG

520

912

45

≥ 150*

≥ 3

0

≥ 50

595

7

42

26

≥ 600490

±1850±1

≤ 1

50

≥ 1

0 ≥ 25

45

30-5

0

≥ 8

0 ≥ 5

* Minimum distance from mounting cut-out to the wall

** Position of gas connection in cut-out

Designation Art. no. Mains connec-tion

Fuse Rated load Gas type Connectioncable

Country

GK41TG 717.3.49 220-240 V~50/60 Hz

3 A 1 W Natural gas H/E/(L)20 (25) mbar

1 m, without plug RU/UA, UK, LB,HK, SG, TR, ITGK51TPG 701.3.49

701.3.69 Natural gas 1 kPa 1 m, AU plug AU

11

V-ZUG Ltd Planning aid J001.059-12Industriestrasse 66, P.O. Box 59, 6301 ZugTel. +41 58 767 67 67, Fax +41 58 767 61 61

Kitchen appliances03.09.14

[email protected], www.vzug.com

62

Page 63: Planning aid Kitchen appliances - V-ZUG AG · Kitchen appliances 03.09.14 info@vzug.com, 9. 2 Ovens 2.1 Electrical connection data Appliance Country group * Mains connection Fuse

11.2 Lava grill

GK11TKLG

≥ 100*

≥ 3

0≥ 50

490-500

+2

520

≥ 6

00

302

108

Dra

in c

ock

~128*

≥ 60-5

0270 +2

17

3

* Minimum distance from cut-out for trough to wall

Designation Art. no. Mains connec-tion

Rated load Mains cable Connection cable Country

GK11TKLG 98A.3.30 220–240 V~50/60 Hz

13 A 2400 W 1 m, without plug RU/UA, UK, LB, HK, SG, TR, CN

11.3 2-zone induction hob

GK21TI

53

≥ 600

≥ 40

≥ 50

≥ 60/50

520

302

270 +2-0

490-

500+2

-0

20/3

0*

* with oven

Designation Art. no. Mains connec-tion

Fuse Rated load Connection cable Country

GK21TI 834.3.89 220-240 V~50/60 Hz

16 A 3700 W 1.1 m, without plug RU/UA, UK, LB, HK, SG, TR, CN

11

V-ZUG Ltd Planning aid J001.059-12Industriestrasse 66, P.O. Box 59, 6301 ZugTel. +41 58 767 67 67, Fax +41 58 767 61 61

Kitchen appliances03.09.14

[email protected], www.vzug.com

63

Page 64: Planning aid Kitchen appliances - V-ZUG AG · Kitchen appliances 03.09.14 info@vzug.com, 9. 2 Ovens 2.1 Electrical connection data Appliance Country group * Mains connection Fuse

11.4 Installation examples for combined gas edition arrangement

Arrangement A (1 × H64140)

30

28830

30288

30288

490 / 500

600

50

R3

≥ 50

30 576+230

36

H64140

Connection strip

Arrangement B (2 × H64140)

30

30

30

30 882+23030

30288

30288

30306

490 / 500

600

50

R3

≥ 5036

H64140

Connection strip

11

V-ZUG Ltd Planning aid J001.059-12Industriestrasse 66, P.O. Box 59, 6301 ZugTel. +41 58 767 67 67, Fax +41 58 767 61 61

Kitchen appliances03.09.14

[email protected], www.vzug.com

64

Page 65: Planning aid Kitchen appliances - V-ZUG AG · Kitchen appliances 03.09.14 info@vzug.com, 9. 2 Ovens 2.1 Electrical connection data Appliance Country group * Mains connection Fuse

Arrangement C (3 × H64140)

30

30 1188+23030

30

30

30

30

30288

30288

30306490 / 500

600

50

R3

≥ 50

30306

36

H64140

Connection strip

Arrangement D (1 × H64140)

30

876+2

60

30

30288

490 / 500

600

50

R3

≥ 50

60588

60

36

H64140

Connection strip

11

V-ZUG Ltd Planning aid J001.059-12Industriestrasse 66, P.O. Box 59, 6301 ZugTel. +41 58 767 67 67, Fax +41 58 767 61 61

Kitchen appliances03.09.14

[email protected], www.vzug.com

65

Page 66: Planning aid Kitchen appliances - V-ZUG AG · Kitchen appliances 03.09.14 info@vzug.com, 9. 2 Ovens 2.1 Electrical connection data Appliance Country group * Mains connection Fuse

Arrangement E (1 × H64140)

30

1186+2

90

30

30288

490 / 500

600

50

R3

≥ 50

90898

90

36

H64140

Connection strip

Arrangement F (2 × H64140)

30

60

30

30288

490 / 500

600

50

R3

≥ 50

60588

60

90898

30306

30

90

1182+230

30 90 1492+230

36

H64140

Connection strip

11

V-ZUG Ltd Planning aid J001.059-12Industriestrasse 66, P.O. Box 59, 6301 ZugTel. +41 58 767 67 67, Fax +41 58 767 61 61

Kitchen appliances03.09.14

[email protected], www.vzug.com

66

Page 67: Planning aid Kitchen appliances - V-ZUG AG · Kitchen appliances 03.09.14 info@vzug.com, 9. 2 Ovens 2.1 Electrical connection data Appliance Country group * Mains connection Fuse

Arrangement G (2 × H64140)

30

60

30

30288

490 / 500

600

50

R3

≥ 50

60588

60

90916

30

90

1182+230

30 90 1492+230

30288

36

H64140

Connection strip

11

V-ZUG Ltd Planning aid J001.059-12Industriestrasse 66, P.O. Box 59, 6301 ZugTel. +41 58 767 67 67, Fax +41 58 767 61 61

Kitchen appliances03.09.14

[email protected], www.vzug.com

67

Page 68: Planning aid Kitchen appliances - V-ZUG AG · Kitchen appliances 03.09.14 info@vzug.com, 9. 2 Ovens 2.1 Electrical connection data Appliance Country group * Mains connection Fuse

12 Range hoods

Technical information on the range hoods can be found in the document J328.35 «TechInfo for range hoods» and the pricelist.

12.1 General notes

If other firing systems are being used at the same time (e.g. wood, gas, oil or coal fired heating appliances), safe operation isonly possible providing a room negative pressure of 4 Pa (0.04 mbar) is not exceeded at the location of the appliance.Risk of toxic fumes! An adequate flow of fresh air must be guaranteed e.g. via non-closable openings in doors or windowsand in combination with an air-intake/exhaust-air wall box or by other technical means.

If the appliance is installed over gas hobs, each cooking zone must be fitted with an ignition fuse and the minimum distances(see «Distance above hob») must be adhered to.

Efficient repairs can only be guaranteed if it is possible to uninstall the whole appliance at any time without causing anydamage.

Extraction mode

The extracted air must not be fed into a chimney which is used for exhausting fumes from appliances burning gas or otherfuels.Observe the local fire regulations.

Installation notes• In addition to the correct dimensioning of the exhaust duct, it is also necessary to ensure a sufficient inflow of fresh air.

Exhaust air needs fresh air.

• Avoid routing the exhaust duct to the side through the flue casing.

• Planning features for non-destructive de-installation and maintenance of the appliance:

– Do not route telescopic casing in suspended ceilings.

– Avoid silicon joints between the telescopic casing and the appliance.

– All plastering, plasterboarding, wall papering or painting work is to be carried out prior to installing the appliance.

12

V-ZUG Ltd Planning aid J001.059-12Industriestrasse 66, P.O. Box 59, 6301 ZugTel. +41 58 767 67 67, Fax +41 58 767 61 61

Kitchen appliances03.09.14

[email protected], www.vzug.com

68

Page 69: Planning aid Kitchen appliances - V-ZUG AG · Kitchen appliances 03.09.14 info@vzug.com, 9. 2 Ovens 2.1 Electrical connection data Appliance Country group * Mains connection Fuse

12.2 Island hoods

Applicable to the following hoods:

• Telescopic casing (adjustable) is supplied in up to 4 basic heights A.

• For activation of external motor flaps, roof ventilators, room fans, etc., see document P60.008.

• Mains connection directly above range hood, connection cable 1.2 m with plug.

DI-Premira DIPQ10 (63007), DIPQ13 (63006)Operatingmode

Extraction/recirculation

Mains connec-tion

220-240 V~ 50/60 Hz, 138.8 W Illumination 4 × 2.2 W Fan speeds 4

Noise level 41-64 dB(A) Fuse 10 A Motor 1 × 130 W Weight ~31.5/35 kgOptions connection (optional) Max. 300 W

Drilling plan (view X)

200

100

00 200 400 600

0

10

20

30

40

Flow volume [m³/h]

pst

at [

Pa]

p stat [m

m W

S/C

E]

300

400

3

2

1

4 intensive

Detail Y

24

10

1

239

55

BA

ø 150

1000/1300 700

h

X

330330

¹

324.8297

240.4180

80

240.4

293.5

324.820

180

55 1

00

R80

h:Extraction/recirculation 2.5 kg: 420 mm

Extraction with metal ring: 477 mmRecirculation 5 kg: 565 mm

¹ For recirculation air (see detail Y):- Air outlet left/right: always possible- Air outlet front/back:

Telescopic casing extracted airAvailable in 3 basic heights A:475-670 mm (standard)675-910 mm (medium)915-1305 mm (long)

for 2.5 kg activated charcoal if A ≥ 605 mmfor 5 kg activated charcoal if A ≥ 750 mm

Telescopic casing recirculation airAvailable in 4 basic heights A:

Distance above hobMinimum distance B

565-645 mm: 2.5 kg activated charcoal (standard)650-780 mm: 5 kg activated charcoal (standard)785-995 mm: 5 kg activated charcoal (medium)1000-1410 mm: 5 kg activated charcoal (long)

For electric hob: 500 mmFor gas hob: 650 mm

12

V-ZUG Ltd Planning aid J001.059-12Industriestrasse 66, P.O. Box 59, 6301 ZugTel. +41 58 767 67 67, Fax +41 58 767 61 61

Kitchen appliances03.09.14

[email protected], www.vzug.com

69

Page 70: Planning aid Kitchen appliances - V-ZUG AG · Kitchen appliances 03.09.14 info@vzug.com, 9. 2 Ovens 2.1 Electrical connection data Appliance Country group * Mains connection Fuse

DI-Mistral DI-M10 (996), DI-M12 (997)Operatingmode

Extraction/recirculation

Mains connec-tion

220-240 V~ 50/60 Hz, 640 W Illumination 4 × 20 W, 12 V~ Fan speeds 4

Noise level 40-59 dB(A) Fuse 10 A Motor 1 × 260 W Weight ~42/48 kgOptions connection Max. 300 W

Drilling plan (view X)

0 200 400 600 800

400

300

200

100

0

40

30

20

10

0

1

23

4

pst

at [

mm

WS

/CE

]

pst

at [

Pa

]

Flow volume [m³/h]

Intensive

25

10

0

Detail Y

166

~4

60

68

BA

ø 150

1000/1200

700

44

0

X

299257

ø 10

ø 102

15

16

4

88

25

7

207

299

235

For recirculation

air, see detail Y

for air outlet

Telescopic casing extracted airAvailable in 3 basic heights A:

Telescopic casing recirculation airAvailable in 3 basic heights A:

Distance above hobMinimum distance B

550-745 mm (standard)750-1000 mm (medium)1000-1250 mm (long)

600-745 mm (standard)750-1000 mm (medium)1000-1250 mm (long)

For electric hob: 600 mmFor gas hob: 750 mm

DI-B10 (816), DI-B12 (63008)Operatingmode

Extraction/recirculation

Mains connec-tion

220-240 V~ 50/60 Hz, 640 W Illumination 4 × 20 W, 12 V~ Fan speeds 4

Noise level 40-59 dB(A) Fuse 10 A Motor 1 × 260 W Weight ~36 kgOptions connection Max. 300 W

Drilling plan (view X)

0 200 400 600 800

400

300

200

100

0

40

30

20

10

0

1

23

4

pst

at [

mm

WS

/CE

]

pst

at [

Pa

]

Flow volume [m³/h]

Intensive

25

10

0

Detail Y

166

68

BA

ø 150

1000/1200 700

44

0

X

299257

ø 10

ø 10

21

5

16

4

88

25

7

207

299

235

For recirculation

air, see Detail Y

for air outlets

Telescopic casing extracted airAvailable in 3 basic heights A:

Telescopic casing recirculation airAvailable in 3 basic heights A:

Distance above hobMinimum distance B

550-745 mm (standard)750-1000 mm (medium)1000-1250 mm (long)

600-745 mm (standard)750-1000 mm (medium)1000-1250 mm (long)

For electric hob: 600 mmFor gas hob: 750 mm

12

V-ZUG Ltd Planning aid J001.059-12Industriestrasse 66, P.O. Box 59, 6301 ZugTel. +41 58 767 67 67, Fax +41 58 767 61 61

Kitchen appliances03.09.14

[email protected], www.vzug.com

70

Page 71: Planning aid Kitchen appliances - V-ZUG AG · Kitchen appliances 03.09.14 info@vzug.com, 9. 2 Ovens 2.1 Electrical connection data Appliance Country group * Mains connection Fuse

DI-B14 (821)Operatingmode

Extraction/recirculation

Mains connec-tion

220-240 V~ 50/60 Hz, 680 W Illumination 6 × 20 W, 12 V~ Fan speeds 4

Noise level 40-59 dB(A) Fuse 10 A Motor 1 × 260 W Weight ~45 kgOptions connection Max. 300 W

Drilling plan (view X)

0 200 400 600 800

400

300

200

100

0

40

30

20

10

0

1

23

4

pst

at [

mm

WS

/CE

]

pst

at [

Pa

]

Flow volume [m³/h]

Intensive

25

10

0

Detail Y

166

80

BA

X

299257

ø 10

ø 10

21

5

16

4

88

25

7

207

299

235

ø 150

45

3

1400 700

For recirculation

air, see Detail Y

for air outlets

Telescopic casing extracted airAvailable in 3 basic heights A:

Telescopic casing recirculation airAvailable in 3 basic heights A:

Distance above hobMinimum distance B

562-757 mm (standard)762-1012 mm (medium)1012-1262 mm (long)

612-757 mm (standard)762-1012 mm (medium)1012-1262 mm (long)

For electric hob: 600 mmFor gas hob: 750 mm

DI-SE10 (076), DI-SE12 (077)Operatingmode

Extraction/recirculation

Mains connec-tion

220-240 V~ 50/60 Hz, 455 W Illumination 4 × 20 W, 12 V~ Fan speeds 4

Noise level 44-64 dB(A) Fuse 10 A Motor 1 × 175 W Weight ~21/23 kgOptions connection Max. 200 W

Drilling plan (view X)

0 100 200 300 400 500 6000

100

200

300

400

500

2

10

10

20

30

40

50

pst

at [

mm

WS

/CE

]

pst

at [

Pa]

4

3

Flow volume [m³/h]

Intensive

Detail Y

36

77

135

273

276.5

236.4

190

14

8

25

222

2506001000/1200

B

60

A ²

316 ¹

X

277277

ø 150

458

¹ With metal ring: 356 mm² Grid spacing: 10 mm

For recirculation air,sett Detail Y for selsctable air outletleft/right or front/back

Telescopic casing extracted airAvailable in 3 basic heights A:

Telescopic casing recirculation airAvailable in 3 basic heights A:

Distance above hobMinimum distance B

550-750 mm (standard)750-905 mm (medium)905-1265 mm (long)

650-750 mm (standard)750-980 mm (medium)980-1340 mm (long)

For electric hob: 600 mmFor gas hob: 750 mm

12

V-ZUG Ltd Planning aid J001.059-12Industriestrasse 66, P.O. Box 59, 6301 ZugTel. +41 58 767 67 67, Fax +41 58 767 61 61

Kitchen appliances03.09.14

[email protected], www.vzug.com

71

Page 72: Planning aid Kitchen appliances - V-ZUG AG · Kitchen appliances 03.09.14 info@vzug.com, 9. 2 Ovens 2.1 Electrical connection data Appliance Country group * Mains connection Fuse

12.3 Wall hoods

Applicable to the following hoods:

• Consider type of piping (straight or elbow).

• Telescopic casing (adjustable) available in up to 4 basic heights A.

• For activation of external motor flaps, roof ventilators, room fans, etc., see document P60.008.

• Connection directly behind telescopic casing, connection cable 1.2 m with plug.

Positions of electrical connections

The specified dimensions are valid for straight exhaust air piping. If exhaust air pipings with an elbow are used, the dimen-sions must be adapted accordingly.

Designation Connection from lower part ofappliance

Connection from centre Type of connection

DW-Premira Recirculation 2,5 kg & extraction:495 mm

Recirculation 5 kg: 645 mm

80 mm

Flush power socket 230 VDW-Forano

DW-Levantemin. 540 mm 80 mm

DW-Mistral, DW-Bora,DW-SMC, DW-SE

550 mm 56 mm

DW-Premira DWPQ12 (62006)Operatingmode

Extraction/recirculation

Mains connec-tion

220-240 V~ 50/60 Hz, 136.6 W Illumination 3 × 2.2 W Fan speeds 4

Noise level 41-64 dB(A) Fuse 10 A Motor 1 × 130 W Weight ~29 kgOptions connection (optional) Max. 300 W

110ø 150

42

0 ¹

/56

5 ²

/ 4

77

³

1198 550

BA

3303102501

14

00

¹/

54

8 ²

18055

600 ¹

/ 7

50

²

For recirculation air,see detail Yfor air outlet

200

100

00 200 400 600

0

10

30

40

Flow volume [m³/h]

pst

at [

Pa]

pst

at [

mm

WS

/CE

]

300

400

20

3

2

1

4 Intensive

¹ Extraction/recirculation 2.5 kg² Recirculation 5 kg³ Extraction with metal ring 2

4

10

1

Detail Y 34,7239

Use of stone cladding20 mm thick wall panels (granite, marble)are possible.

20

Telescopic casing extracted airAvailable in 3 basic heights A:460-660 mm (standard)660-875 mm (medium)875-1305 mm (long)

Telescopic casing recirculation airAvailable in 4 basic heights A:565-650 mm: 2.5 kg activated charcoal (standard)650-780 mm: 5 kg activated charcoal (standard)780-995 mm: 5 kg activated charcoal (medium)995-1425 mm: 5 kg activated charcoal (long)

Distance above hobMinimum distance BFor electric hob: 500 mmFor gas hob: 650 mm

12

V-ZUG Ltd Planning aid J001.059-12Industriestrasse 66, P.O. Box 59, 6301 ZugTel. +41 58 767 67 67, Fax +41 58 767 61 61

Kitchen appliances03.09.14

[email protected], www.vzug.com

72

Page 73: Planning aid Kitchen appliances - V-ZUG AG · Kitchen appliances 03.09.14 info@vzug.com, 9. 2 Ovens 2.1 Electrical connection data Appliance Country group * Mains connection Fuse

DW-Premira DWPQ9 (62007)Operatingmode

Extraction/recirculation

Mains connec-tion

220-240 V~ 50/60 Hz, 134.4 W Illumination 2 × 2.2 W Fan speeds 4

Noise level 41-64 dB(A) Fuse 10 A Motor 1 × 130 W Weight ~25.5 kgOptions connection (optional) Max. 300 W

110ø 150

42

0 ¹

/56

5 ²

/ 4

77

³

898 550

BA

3303102501

14

00

¹/

54

8 ²

18055

For recirculation air, see detail Y

for air outlet

60

0 ¹

/7

50

²

200

100

00 200 400 600

0

10

30

40

Flow volume [m³/h]

pst

at [

Pa]

pst

at [

mm

WS

/CE

]

300

400

20

3

2

1

4 Intensive

¹ Extraction/recirculation 2.5 kg² Recirculation 5 kg³ Extraction with metal ring 2

4

10

1

Detail Y 34,7239

Use of stone cladding20 mm thick wall panels (granite, marble)are possible.

20

Telescopic casing extracted airAvailable in 3 basic heights A:460-660 mm (standard)660-875 mm (medium)875-1305 mm (long)

Telescopic casing recirculation airAvailable in 4 basic heights A:565-650 mm: 2.5 kg activated charcoal (standard)650-780 mm: 5 kg activated charcoal (standard)780-995 mm: 5 kg activated charcoal (medium)995-1425 mm: 5 kg activated charcoal (long)

Distance above hobMinimum distance BFor electric hob: 500 mmFor gas hob: 650 mm

DW-Mistral DW-M9 (991), DW-M12 (992)Operatingmode

Extraction/recirculation

Mains connec-tion

220-240 V~ 50/60 Hz, 640 W Illumination 4 × 20 W, 12 V~ Fan speeds 4

Noise level 40-59 dB(A) Fuse 10 A Motor 1 × 260 W Weight ~42/48 kgOptions connection Max. 300 W

21516

450

154

~700

ø 150

440

~420

67

900/1200

550

BA

304260

140

71

For recirculation

air, see detail Y

for air outlet

0 200 400 600 800

400

300

200

100

0

40

30

20

10

0

1

23

4p

stat [

mm

WS

/CE

]

pst

at [

Pa]

Flow volume [m³/h]

Intensive

Use of stone cladding20 mm thick wall panels (granite,marble) are possible.

20

Telescopic casing extracted airAvailable in 2 basic heights A:500-820 mm (standard)820-1150 mm (long)

Telescopic casing recirculationairAvailable in 2 basic heights A:600-820 mm (standard)820-1150 mm (long)

Distance above hobMinimum distance BFor electric hob: 600 mmFor gas hob: 750 mm

25

10

0

Detail Y

166

12

V-ZUG Ltd Planning aid J001.059-12Industriestrasse 66, P.O. Box 59, 6301 ZugTel. +41 58 767 67 67, Fax +41 58 767 61 61

Kitchen appliances03.09.14

[email protected], www.vzug.com

73

Page 74: Planning aid Kitchen appliances - V-ZUG AG · Kitchen appliances 03.09.14 info@vzug.com, 9. 2 Ovens 2.1 Electrical connection data Appliance Country group * Mains connection Fuse

DW-B9 (993), DW-B12 (62008)Operatingmode

Extraction/recirculation

Mains connec-tion

220-240 V~ 50/60 Hz, 640 W Illumination 4 × 20 W, 12 V~ Fan speeds 4

Noise level 40-59 dB(A) Fuse 10 A Motor 1 × 260 W Weight ~36 kgOptions connection Max. 300 W

147ø 150

44

0

900/1200 550

BA

3042602151

64

50~

70

0

140

71

67

For recirculation air,

see detail Y

for air outlet

0 200 400 600 800

400

300

200

100

0

40

30

20

10

0

1

23

4

pst

at [

mm

WS

/CE

]

pst

at [

Pa]

Flow volume [m³/h]

Intensive

Use of stone cladding20 mm thick wall panels (granite,marble) are possible.

20

Telescopic casing extracted airAvailable in 2 basic heights A:500-820 mm (standard)820-1150 mm (long)

Telescopic casing recirculationairAvailable in 2 basic heights A:600-820 mm (standard)820-1150 mm (long)

Distance above hobMinimum distance BFor electric hob: 600 mmFor gas hob: 750 mm

25

10

0

Detail Y

166

DW-B14 (994)Operatingmode

Extraction/recirculation

Mains connec-tion

220-240 V~ 50/60 Hz, 680 W Illumination 6 × 20 W, 12 V~ Fan speeds 4

Noise level 40-59 dB(A) Fuse 10 A Motor 1 × 260 W Weight ~45 kgOptions connection Max. 300 W

154ø 150

453

1400 550

BA

3042602151

6461~

713

140

80

53

800

For recirculation air,

see detail Y for

air outlet

0 200 400 600 800

400

300

200

100

0

40

30

20

10

0

1

23

4

pst

at [

mm

WS

/CE

]

pst

at [

Pa]

Flow volume [m³/h]

Intensive

Use of stone cladding20 mm thick wall panels (granite,marble) are possible.

20

Telescopic casing extracted airAvailable in 2 basic heights A:513-833 mm (standard)833-1163 mm (long)

Telescopic casing recirculationairAvailable in 2 basic heights A:613-833 mm (standard)833-1163 mm (long)

Distance above hobMinimum distance BFor electric hob: 600 mmFor gas hob: 750 mm

25

10

0

Detail Y

166

12

V-ZUG Ltd Planning aid J001.059-12Industriestrasse 66, P.O. Box 59, 6301 ZugTel. +41 58 767 67 67, Fax +41 58 767 61 61

Kitchen appliances03.09.14

[email protected], www.vzug.com

74

Page 75: Planning aid Kitchen appliances - V-ZUG AG · Kitchen appliances 03.09.14 info@vzug.com, 9. 2 Ovens 2.1 Electrical connection data Appliance Country group * Mains connection Fuse

DW-SE9 (059)Operatingmode

Extraction/recirculation

Mains connec-tion

220-240 V~ 50/60 Hz, 415 W Illumination 2 × 20 W, 12 V~ Fan speeds 4

Noise level 44-64 dB(A) Fuse 10 A Motor 1 × 175 W Weight ~14 kgOptions connection Max. 200 W

477898

240250

AB

60

30

30

1 230~5

76

170

ø 15082

31

6 ¹

45

8

For recirculationair, see deatail Yfor air outlet

* With metal ring: 356 mm

0 100 200 300 400 500 6000

100

200

300

400

500

2

10

10

20

30

40

50

pst

at [

mm

WS

/CE

]

pst

at [

Pa

]

4

3

Flow volume [m³/h]

Intensive

Use of stone cladding20 mm thick wall panels (granite,marble) are possible.

20

Telescopic casing extracted airAvailable in 2 basic heights A:615-825 mm (standard)615-1125 mm (long)

Telescopic casing recirculationairAvailable in 2 basic heights A:700-825 mm (standard)700-1145 mm (long)

Distance above hobMinimum distance BFor electric hob: 600 mmFor gas hob: 750 mm 3

6.5

77

Detail Y 24142

DW-SE12 (068)Operatingmode

Extraction/recirculation

Mains connec-tion

220-240 V~ 50/60 Hz, 435 W Illumination 3 × 20 W, 12 V~ Fan speeds 4

Noise level 44-64 dB(A) Fuse 10 A Motor 1 × 175 W Weight ~20 kgOptions connection Max. 200 W

4771198

240250

AB

60

30

1

230~5

76

170

ø 150

45

8

82

31

6 ¹

30

For recirculationair, see deatail Yfor air outlet

* With metal ring: 356 mm

0 100 200 300 400 500 6000

100

200

300

400

500

2

10

10

20

30

40

50

pst

at [

mm

WS

/CE

]

pst

at [

Pa

]

4

3

Flow volume [m³/h]

Intensive

Use of stone cladding20 mm thick wall panels (granite,marble) are possible.

20

Telescopic casing extracted airAvailable in 2 basic heights A:615-825 mm (standard)615-1125 mm (long)

Telescopic casing recirculationairAvailable in 2 basic heights A:700-825 mm (standard)700-1145 mm (long)

Distance above hobMinimum distance BFor electric hob: 600 mmFor gas hob: 750 mm 3

6.5

77

Detail Y 24142

12

V-ZUG Ltd Planning aid J001.059-12Industriestrasse 66, P.O. Box 59, 6301 ZugTel. +41 58 767 67 67, Fax +41 58 767 61 61

Kitchen appliances03.09.14

[email protected], www.vzug.com

75

Page 76: Planning aid Kitchen appliances - V-ZUG AG · Kitchen appliances 03.09.14 info@vzug.com, 9. 2 Ovens 2.1 Electrical connection data Appliance Country group * Mains connection Fuse

DW-Levante DW-L9 (990)Operatingmode

Extraction/recirculation

Mains connec-tion

220-240 V~ 50/60 Hz, 290 W Illumination 2 × 20 W, 12 V~ Fan speeds 4

Noise level 41-64 dB(A) Fuse 10 A Motor 1 × 250 W Weight ~34 kg

For recirculation air, see detail Y for air outlet

170

30

160

240250

ø 150

765

¹

62

6900

AB

724

.7~102

5

290

750

352309

80

* With metal ring: 805 mm

0 200 400 600 800

400

300

200

100

0

40

500 50

30

20

10

0

1

3

4

pst

at [

mm

WS

/CE

]

pst

at [

Pa

]

2

Flow volume [m³/h]

Intensive

Use of stone cladding20 mm thick wall panels (granite,marble) are possible.

20

Telescopic casing extracted airAvailable in 2 basic heights A:1280-1490 mm (standard)1280-1790 mm (long)

Telescopic casing recirculationairAvailable in 2 basic heights A:1365-1490 mm (standard)1365-1810 mm (long) Standard version recirculation air:without telescopic casing

Distance above hobMinimum distance BFor electric hob: 300 mmFor gas hob: 400 mm 3

6.5

77

Detail Y 24142

DW-Forano DW-F8 (042)Operatingmode

Extraction/recirculation

Mains connec-tion

220-240 V~ 50/60 Hz, 290 W Illumination 2 × 20 W, 12 V~ Fan speeds 4

Noise level 51-66 dB(A) Fuse 10 A Motor 1 × 250 W Weight ~29 kg

285255

ø 150

17

AB

75

167248

423

46

5.5

49

~7

30

46

0

35

5 ¹

47

0

800

300–540273

For recirculation air, see detail Y for air outlets

¹ For air outlet to the back

0 200 400 600 800

400

300

200

100

0

40

500 50

30

20

10

0

1

3

4

pst

at [

mm

WS

/CE

]

pst

at [

Pa

]

2

Flow volume [m³/h]

Intensive

Use of stone cladding20 mm thick wall panels (granite,marble) are possible.

20

Telescopic casing extracted airAvailable in 2 basic heights A:740-970 mm (standard)970-1274 mm (long)

Telescopic casing recirculationairAvailable in 1 basic height A:1024-1374 mm (long)

Standard version recirculation air:without telescopic casing

Distance above hobMinimum distance B: 650 mm

12614.7

49

76

Detail Y

12

V-ZUG Ltd Planning aid J001.059-12Industriestrasse 66, P.O. Box 59, 6301 ZugTel. +41 58 767 67 67, Fax +41 58 767 61 61

Kitchen appliances03.09.14

[email protected], www.vzug.com

76

Page 77: Planning aid Kitchen appliances - V-ZUG AG · Kitchen appliances 03.09.14 info@vzug.com, 9. 2 Ovens 2.1 Electrical connection data Appliance Country group * Mains connection Fuse

12.4 Built-in hoods

Applicable to the following hoods:• For activation of external motor flaps, roof ventilators, room fans, etc., see document P60.008.

• Connection cable 1.2 m with plug

Positions of electrical connections

The specified dimensions are valid for straight exhaust air piping. If exhaust air pipings with an elbow are used, the dimen-sions must be adapted accordingly.

Designation Connection from floor(plinth height 100 mm)

Connection in niche(from centre to connection)

Type of connection

All models 2050 mm 180 mm Flush power socket230 V

12

V-ZUG Ltd Planning aid J001.059-12Industriestrasse 66, P.O. Box 59, 6301 ZugTel. +41 58 767 67 67, Fax +41 58 767 61 61

Kitchen appliances03.09.14

[email protected], www.vzug.com

77

Page 78: Planning aid Kitchen appliances - V-ZUG AG · Kitchen appliances 03.09.14 info@vzug.com, 9. 2 Ovens 2.1 Electrical connection data Appliance Country group * Mains connection Fuse

DF-Premira DFPQ12 (61013)Operatingmode

Extraction/recirculation

Mains connec-tion

220-240 V~ 50/60 Hz, 136.6 W Illumination 3 × 2.2 W Fan speeds 4

Noise level 40-67 dB(A) Fuse 10 A Motor 1 × 130 W Weight ~27.5 kgOptions connection (optional) Max. 300 W

330-370

292

1200

300-345¹

55

¹

¹

290290

300-345

1198

6755

200

h

ø15030

495

55

BC

pst

at [

Pa

]

100

200

300

400

0

Flow volume [m³/h]200 400 6000

pst

at [

mm

WS

/CE

]

10

20

30

40

0

3

2

1

4 Intensive

Use of stone cladding20 mm thick wall panels(granite, marble) arepossible.

20

h: Extraction/recirculation 2.5 kg: 452 mm, extraction with metal ring: 477 mm, Recirculation 5 kg: 600 mm

Distance above hobMinimum distance BFor electric hob: 500 mmFor gas hob: 650 mm

¹ For wall unit depth of 351-370 mm: additional finished profile required

Finished profile included in scope of delivery: Available as option:Type Width Wall unit depth Article no. Type Width Wall unit depth Article no. DFPQ12 1198 mm 330-350 mm H42660 DFPQ12 1198 mm 351-370 mm H42803

Front coverAvailable as option

Recirculation air set for wall unit without panelAvailable as option, can be combined with H42614 andH42615

Type Material Height C Article no. Type Material Article no. DFPQ12 ChromeClass 410-790 mm H42614 DFPQ12 ChromeClass H42630 DFPQ12 ChromeClass 791-1150 mm H42615

CC

292

300

292

330299

A

For changing the filter, the front cover A must be removable.

12

V-ZUG Ltd Planning aid J001.059-12Industriestrasse 66, P.O. Box 59, 6301 ZugTel. +41 58 767 67 67, Fax +41 58 767 61 61

Kitchen appliances03.09.14

[email protected], www.vzug.com

78

Page 79: Planning aid Kitchen appliances - V-ZUG AG · Kitchen appliances 03.09.14 info@vzug.com, 9. 2 Ovens 2.1 Electrical connection data Appliance Country group * Mains connection Fuse

DF-Premira DFPQ6 (61015), DFPQ9 (61014)Operatingmode

Extraction/recirculation

Mains connec-tion

220-240 V~ 50/60 Hz, 134,4 W Illumination 2 × 2,2 W Fan speeds 4

Noise level 40-67 dB(A) Fuse 10 A Motor 1 × 130 W Weight ~19.5/23.5 kg

330-350

292

600/900

300-325

55290290

300-325

598/898

67

55

200

452¹/600²

ø15030

495

BC

¹ Extraction/recirculation 2.5 kg² Recirculation 5 kg

pst

at [

Pa

]

100

200

300

400

0

Flow volume [m³/h]200 400 6000

pst

at [

mm

WS

/CE

]

10

20

30

40

0

3

2

1

4 Intensive

Use of stone cladding20 mm thick wall panels(granite, marble) arepossible.

20

Distance above hobMinimum distance B:For electric hob: 500 mmFor gas hob: 650 mm

Front coverAvailable as option

Recirculation air set for wall unit without panelAvailable as option

Type Material Height C Article no. Type Material Article no.DFPQ6, DFPQ9 ChromeClass 410-790 mm H42614 DFPQ6, DFPQ9 ChromeClass H42630DFPQ6, DFPQ9 ChromeClass 791-1150 mm H42615

CC

292

300

292

330299

A

Can be combined with front cover H4.2614 and H4.2615

12

V-ZUG Ltd Planning aid J001.059-12Industriestrasse 66, P.O. Box 59, 6301 ZugTel. +41 58 767 67 67, Fax +41 58 767 61 61

Kitchen appliances03.09.14

[email protected], www.vzug.com

79

Page 80: Planning aid Kitchen appliances - V-ZUG AG · Kitchen appliances 03.09.14 info@vzug.com, 9. 2 Ovens 2.1 Electrical connection data Appliance Country group * Mains connection Fuse

DF-Premira SL DFPQSL6 (61008), DFPQSL9 (61007)Operatingmode

Extraction/recirculation

Mains connec-tion

220-240 V~ 50/60 Hz, 134.4 W Illumination 2 × 2.2 W Fan speeds 4

Noise level 40-67 dB(A) Fuse 10 A Motor 1 × 130 W Weight ~12.5/16.5 kgOptions connection (optional) Max. 300 W

330-370 ¹

292

550/600/900

300-345 ¹

290290

300-345 ¹

548/598/898

76

200ø1503

0

480

25

78

h

B

C

pst

at [

Pa

]

100

200

300

400

0

Flow volume [m³/h]200 400 6000

pst

at [

mm

WS

/CE

]

10

20

30

40

0

2

1

4

3

Intensive

Use of stone cladding20 mm thick wall panels(granite, marble) arepossible.

20

h: Extraction/recirculation 2.5 kg: 452 mm, extraction with metal ring: 490 mm, Recirculation 5 kg: 600 mm

Distance above hobMinimum distance BFor electric hob: 500 mmFor gas hob: 650 mm

¹ For wall unit depth of 351-370 mm: additional finished profile required

Finished profile included in scope of delivery: Available as option:Type Width Wall unit depth Type Width Wall unit depth Article no.DFPQSL6 598 mm 330-350 mm DFPQSL6 598 mm 351-370 mm H42805DFPQSL9 898 mm 330-350 mm DFPQSL9 898 mm 351-370 mm H42806

Front coverAvailable as option

Recirculation air set for wall unit without panelavailable as option, can be combined with H42614 and H42615

Type Material Height C Article no. Type Material Article no. DFPQSL6/9 ChromeClass 410-790 mm H42614 DFPQSL5/6/9 ChromeClass H42630 DFPQSL6/9 ChromeClass 791-1150 mm H42615

CC

292

300

292

A

330299

For changing the filter, the front cover A must be remov-able.

12

V-ZUG Ltd Planning aid J001.059-12Industriestrasse 66, P.O. Box 59, 6301 ZugTel. +41 58 767 67 67, Fax +41 58 767 61 61

Kitchen appliances03.09.14

[email protected], www.vzug.com

80

Page 81: Planning aid Kitchen appliances - V-ZUG AG · Kitchen appliances 03.09.14 info@vzug.com, 9. 2 Ovens 2.1 Electrical connection data Appliance Country group * Mains connection Fuse

Concave deflector plate DF-SLG9 (385)Operatingmode

Extraction/recirculation

Mains connec-tion

220-240 V~ 50/60 Hz, 260 W Illumination 2 × 20 W, 12 V~ Fan speeds 4

Noise level 47-65 dB(A) Fuse 10 A Motor 2 × 110 W Weight ~17 kg

13

0 ¹

35

7

16

73

B

900

552

192

≥ 200

≤ 525

280–350

896

14–175

21

0

ø 120ø 150

Wall unit depth 280-350mm²

898 Base

898 Finished profile

Reduction connection

¹ With metal ring: 170 mm² Recirculation version only possible with wall unit depth of 280-330 mm

1

4

400

300

200

100

0

40

30

20

10

00 100 200 300 400 500 600 700

pst

at [

mm

WS

/CE

]

pst

at [

Pa

]

3

2

Flow volume [m³/h]

Use of stone cladding20 mm thick wall panels(granite, marble) arepossible.

20

Distance above hobMinimum distance B:For electric hob: 600 mmFor gas hob: 750 mm

Finished profilesincluded in scope of delivery:

70 75

896

Available as option:

70 37.5

896

Type Profilesection

Width Wall unit depth Article no. Type Profilesection

Width Wall unit depth Articleno.

DF-SLG9 Wide 896 mm 320-350 mm H41759 DF-SLG9 Narrow 896 mm 280–315 mm H41758

12

V-ZUG Ltd Planning aid J001.059-12Industriestrasse 66, P.O. Box 59, 6301 ZugTel. +41 58 767 67 67, Fax +41 58 767 61 61

Kitchen appliances03.09.14

[email protected], www.vzug.com

81

Page 82: Planning aid Kitchen appliances - V-ZUG AG · Kitchen appliances 03.09.14 info@vzug.com, 9. 2 Ovens 2.1 Electrical connection data Appliance Country group * Mains connection Fuse

Concave deflector plate DF-SLG6 (384)Operatingmode

Extraction/recirculation

Mains connec-tion

220-240 V~ 50/60 Hz, 260 W Illumination 2 × 20 W, 12 V~ Fan speeds 4

Noise level 47-65 dB(A) Fuse 10 A Motor 2 × 110 W Weight ~15 kg

≥ 200

192

130 ¹

357

16

≤ 525

280–350

73

600

595

552

14–175

210

B

ø 120ø 150

280-350mm ²

598Base

596

598

596

Reduction connection

Finished profile

Wall unit depth

¹ With metal ring: 170 mm² Recirculation version only possible with wall unit depth of 280-330 mm

1

4

400

300

200

100

0

40

30

20

10

00 100 200 300 400 500 600 700

pst

at [

mm

WS

/CE

]

pst

at [

Pa

]

3

2

Flow volume [m³/h]

Use of stone cladding20 mm thick wall panels(granite, marble) are possible.

20

Distance above hobMinimum distance B:For electric hob: 600 mmFor gas hob: 750 mm

Finished profilesincluded in scope of delivery:

70 75

896

Available as option:

70 37.5

896

Type Profilesection

Width Wall unit depth Article no. Type Profilesection

Width Wall unit depth Article no.

DF-SLG6 Wide 596 mm 320-350 mm H41755 DF-SLG6 Narrow 596 mm 280-315 mm H41754

12

V-ZUG Ltd Planning aid J001.059-12Industriestrasse 66, P.O. Box 59, 6301 ZugTel. +41 58 767 67 67, Fax +41 58 767 61 61

Kitchen appliances03.09.14

[email protected], www.vzug.com

82

Page 83: Planning aid Kitchen appliances - V-ZUG AG · Kitchen appliances 03.09.14 info@vzug.com, 9. 2 Ovens 2.1 Electrical connection data Appliance Country group * Mains connection Fuse

Flat deflector plate DF-SG6 (360)Operatingmode

Extraction/recirculation

Mains connec-tion

220-240 V~ 50/60 Hz, 316 W Illumination 2 × 28 W, 230 V~ Fan speeds 3

Noise level 45-63 dB(A) Fuse 10 A Motor 2 × 130 W Weight ~14 kg

13

0 ¹

35

7

B

552

≤ 525

280–350

596

≤ 155

32

21

0

≥ 200

600

192

ø 120ø 150

30

16 598

Finished profile

Reductionconnection

Wall unit depth 280-350mm ²

¹ With metal ring: 170 mm² Recirculation version only possible with wall unit depth of 280-330 mm

1

2

3

pst

at [

mm

WS

/CE

]

pst

at [

Pa]

500

400

300

200

100

0 100 200 300 400 500

40

30

20

10

50

0600

0

Flow volume [m³/h]

Use of stone cladding20 mm thick wall panels(granite, marble) arepossible.

20

Distance above hobMinimum distance B:For electric hob: 600 mmFor gas hob: 750 mm

Finished profilesincluded in scope of delivery:

Wide75

596

26

Type Profilesection

Width Wall unit depth Article no. ChromeClass

DF-SG6 Wide 596 mm 321-350 mm H42281

Available as option: Narrow

26 24

596

Medium

596

44

26

Type Profilesection

Width Wall unit depth Article no. ChromeClass

DF-SG6 Narrow 596 mm 280-300 mm H42225 DF-SG6 Medium 596 mm 290-320 mm H42226

12

V-ZUG Ltd Planning aid J001.059-12Industriestrasse 66, P.O. Box 59, 6301 ZugTel. +41 58 767 67 67, Fax +41 58 767 61 61

Kitchen appliances03.09.14

[email protected], www.vzug.com

83

Page 84: Planning aid Kitchen appliances - V-ZUG AG · Kitchen appliances 03.09.14 info@vzug.com, 9. 2 Ovens 2.1 Electrical connection data Appliance Country group * Mains connection Fuse

Flat deflector plate DF-SG9 (549)Operatingmode

Extraction/recirculation

Mains connec-tion

220-240 V~ 50/60 Hz, 316 W Illumination 2 × 28 W, 230 V~ Fan speeds 3

Noise level 45-63 dB(A) Fuse 10 A Motor 2 × 130 W Weight ~16 kg

130 ¹

210

357

30

16

B

552

321–350

895

≤ 155

32

≤ 525

900

≥ 200

192

ø 120ø 150

321-350mm ²

898

896

Reduction connection

Finished profile

Base

Wall unit depth

¹ With metal ring: 170 mm² Recirculation version only possible with wall unit depth of 321-330 mm

1

2

3

pst

at [

mm

WS

/CE

]

pst

at [

Pa

]

500

400

300

200

100

0 100 200 300 400 500

40

30

20

10

50

0600

0

Flow volume [m³/h]

Use of stone cladding20 mm thick wall panels(granite, marble) are possible.

20

Distance above hobMinimum distance B:For electric hob: 600 mmFor gas hob: 750 mm

Finished profileincluded in scope of delivery:

70 75

896

Type Profilesection

Width Wall unit depth Article no. ChromeClass

DF-SG9 Wide 896 mm 321-350 mm H42294

12

V-ZUG Ltd Planning aid J001.059-12Industriestrasse 66, P.O. Box 59, 6301 ZugTel. +41 58 767 67 67, Fax +41 58 767 61 61

Kitchen appliances03.09.14

[email protected], www.vzug.com

84

Page 85: Planning aid Kitchen appliances - V-ZUG AG · Kitchen appliances 03.09.14 info@vzug.com, 9. 2 Ovens 2.1 Electrical connection data Appliance Country group * Mains connection Fuse

DHL8 (64001), DHL11 (64002)Operatingmode

Extraction/recirculation

Mains connec-tion

220-240 V~ 50/60 Hz, 200 W Illumination 4 × 3 W Fan speeds 4

Noise level 40-61 dB(A) Fuse 10 A Motor 188 W Weight ~22.5/30.5 kg

300

35

5

800/1100

300

275 163.5 ø150

350

24

X

Y

500

400

300

200

100

00 100 200 300 400 500 600

0

10

20

30

40

50

Flow volume [m³/h]

pst

at [

Pa

]

pst

at [

mm

WS

/CE

]4 Intensive

3

2

1

View Y

205

The range hood can be converted so that the exhaustair connection is at the back of the appliance. Distance above hobMinimum distance BFor electric hob: 500 mmFor gas hob: 750 mm

Cut-out for wall unit (view X)

791¹/1091¹

807–885/1107–1185

28

30

35

0

¹ Cut-out measurements Use of stone cladding

20 mm thick wall panels (granite,marble) are possible.

20

12

V-ZUG Ltd Planning aid J001.059-12Industriestrasse 66, P.O. Box 59, 6301 ZugTel. +41 58 767 67 67, Fax +41 58 767 61 61

Kitchen appliances03.09.14

[email protected], www.vzug.com

85

Page 86: Planning aid Kitchen appliances - V-ZUG AG · Kitchen appliances 03.09.14 info@vzug.com, 9. 2 Ovens 2.1 Electrical connection data Appliance Country group * Mains connection Fuse

12.5 Air recycling cassette (LRC)

• Installation in ceiling cover strip

Operating mode Suitable for all built-in range hoods (exception: DF-U!)Replacement activated charcoal filter H40770Pipe connector supplied 1 × ø 125 mmWeight ~6 kg

13

0

530

283

515

≥ 1

0

330

≥ 290

512

133

17–24

11

4

11

2

= =

ø 125

75

20°

12.6 Air outlet cassette (LAC)

• Installation in ceiling cover strip

Operating mode Suitable for all built-in range hoods (exception: DF-U!)Pipe connector supplied 1 × ø 125 mmReduction connections supplied for rangehoods

ø 150 to ø 125 mm

Weight ~5 kg

13

0

530

283

515

≥ 1

0

330

≥ 290

512

133

17–24

11

4

11

2

= =

ø 125

75

20°

12

V-ZUG Ltd Planning aid J001.059-12Industriestrasse 66, P.O. Box 59, 6301 ZugTel. +41 58 767 67 67, Fax +41 58 767 61 61

Kitchen appliances03.09.14

[email protected], www.vzug.com

86

Page 87: Planning aid Kitchen appliances - V-ZUG AG · Kitchen appliances 03.09.14 info@vzug.com, 9. 2 Ovens 2.1 Electrical connection data Appliance Country group * Mains connection Fuse

13 Refrigerators

13.1 General notes

Insufficient ventilation can cause a malfunction and shorten the life of the appliance.

Heavy door panel weights shorten the service life of the door hinges.

Efficient repairs can only be guaranteed if it is possible to uninstall the whole appliance at any time without causing anydamage.

In an open-plan kitchen and living room, a raised noise level can be expected if the ventilation slits face into the room.

13.2 Electrical connection data

Appliance Energy efficiencyclass

Mains connection Fuse Mains cable

RefrigeratorsCooltronic 60i SN-ST

230 V~ 50 Hz

10 A

2.2 m, with plug

Noblesse 60iPrestige P 60i eco SN-TFutura 60i

SN-STRoyal 60iDe Luxe 60iMagnum 60i eco SN-T 230 V~ 50 Hz 2.5 m, with plugKomfort 60i N-STWinecoolerWinecooler SL 60 SN-ST 230 V~ 50 Hz 10 A 2.1 m, with plug

13.3 Room temperature

Climate class Minimum MaximumSN +10 °C +32 °CN +16 °C +32 °CST +16 °C +38 °CT +16 °C +43 °C

13.4 Niche ventilation

Shadow gaps for air circulation – even if extending over the width of several units – are insufficient.

13

V-ZUG Ltd Planning aid J001.059-12Industriestrasse 66, P.O. Box 59, 6301 ZugTel. +41 58 767 67 67, Fax +41 58 767 61 61

Kitchen appliances03.09.14

[email protected], www.vzug.com

87

Page 88: Planning aid Kitchen appliances - V-ZUG AG · Kitchen appliances 03.09.14 info@vzug.com, 9. 2 Ovens 2.1 Electrical connection data Appliance Country group * Mains connection Fuse

13.5 Refrigerators

Cooltronic 60i (51029) Noblesse 60i (51028)KC 60i (integrable in niche height 1778 mm)Maximum permissible weight of door panel is 17.5 kg

KN 60i (integrable)Maximum permissible weight of door panel: 17.5 kg

1270+

a-b/2

508+

a-b/2

a

≤ 594 545

54816–20

560–568

17781776

+2 0

a

≥ 550

≥ 200 cm²

≥ 200 cm²

≥ 50

1270+

a-b/2

508+

a-b/2

a

≤ 594 545

54816–20

560–568

1778

1776

+2 0

a

≥ 550

≥ 200 cm²

≥ 200 cm²

≥ 50

Prestige P 60i eco (51027, 51052) Magnum 60i eco (51031)KRRP 60i eco (integrable in niche height 1778 mm)Maximum permissible weight of door panel is 17.5 kg

KM 60i eco (integrable)Maximum permissible weight of door panel is 25 kg

1143+

a-b/2

635+

a-b/2

a

≤ 594 545

54816–20

560–568

1778

1776

+2 0

a

≥ 550

≥ 200 cm²

≥ 200 cm²

≥ 50

1778+

2 0

≥ 550

≥ 200 cm²

≥ 200 cm²

≥ 50

1778+

a

1770

54816–20

≤ 594 545

560–568

a Niche overlapb Gap (≥ 4 mm)

13

V-ZUG Ltd Planning aid J001.059-12Industriestrasse 66, P.O. Box 59, 6301 ZugTel. +41 58 767 67 67, Fax +41 58 767 61 61

Kitchen appliances03.09.14

[email protected], www.vzug.com

88

Page 89: Planning aid Kitchen appliances - V-ZUG AG · Kitchen appliances 03.09.14 info@vzug.com, 9. 2 Ovens 2.1 Electrical connection data Appliance Country group * Mains connection Fuse

Futura 60i (51020) Royal 60i (51018)KF 60i (integrable in niche height 1524 mm)Maximum permissible weight of door panel is 17.5 kg

KR 60i (integrable)Maximum permissible weight of door panel: 17.5 kg

889+

a-b/2

635+

a-b/2

a

≤ 594 545

54816–20

560–56815241522

+2 0

a

≥ 550

≥ 200 cm²

≥ 200 cm²

≥ 50

560–568

≥ 550

≥ 200 cm²

≥ 200 cm²

≥ 50

1522

1524+

a

54816–20

≤ 594 545

1524+2 0

De Luxe 60i (51017) Komfort 60i (51048)KL 60i (integrable in niche height 1524 mm)Maximum permissible weight of door panel is 17.5 kg

KK 60i (integrable)Maximum permissible weight of door panel is 17.5 kg

560–568

≥ 550

≥ 200 cm²

≥ 200 cm²

≥ 50

1522

1524+

a

54816–20

≤ 594 545

1524+2 0

17

≥ 550

100–185

545

16–20

100–185

600

597

≥ 680

30–60

≥ 600

595

819–869

(≤ 889)

820–870

(≤ 890)

3A

Ventilation partintegrated in plinth

Plinth must be recessed for ventilation purposes

Detail A

a Niche overlapb Gap (≥ 4 mm)

Installation kit for stone cladding is enclosed: H72998

13

V-ZUG Ltd Planning aid J001.059-12Industriestrasse 66, P.O. Box 59, 6301 ZugTel. +41 58 767 67 67, Fax +41 58 767 61 61

Kitchen appliances03.09.14

[email protected], www.vzug.com

89

Page 90: Planning aid Kitchen appliances - V-ZUG AG · Kitchen appliances 03.09.14 info@vzug.com, 9. 2 Ovens 2.1 Electrical connection data Appliance Country group * Mains connection Fuse

13.6 Winecoolers

Winecooler SL (629)KW-SL/60

594 566

873

547

886

≥ 200 cm²

560–568

≥ 550

≥ 200 cm²

≥ 50

H

874–889

X

Y

Detail X

U ²

H1

Detail Y

H U ¹

1

Niche height

HInstallation kit

Art. no.Installation kit

HeightOverlap

U1 U2

874-877 - - 6 mm 3-6 mm877-880 H72435 3 mm 3 mm 3-6 mm

13

V-ZUG Ltd Planning aid J001.059-12Industriestrasse 66, P.O. Box 59, 6301 ZugTel. +41 58 767 67 67, Fax +41 58 767 61 61

Kitchen appliances03.09.14

[email protected], www.vzug.com

90

Page 91: Planning aid Kitchen appliances - V-ZUG AG · Kitchen appliances 03.09.14 info@vzug.com, 9. 2 Ovens 2.1 Electrical connection data Appliance Country group * Mains connection Fuse

14 DishwashersDishwashers with heat pump [➙ see page 100]

14.1 General notes

Efficient repairs can only be guaranteed if it is possible to uninstall the whole appliance at any time without causing anydamage.

At any time it must be possible to pull the appliance out of the niche horizontally without dismantling any part of the cabinet.

For work surfaces that are susceptible to moisture, use work surface protection W70163.

General operating conditionsAmbient temperature: min. 10 °C to max. 35 °C

The appliances are designed for use up to a max. altitude of 2000 m above sea level.

14.2 Electrical connection data / plumbing in

40

12

0

K

L M

N

G1

G2

D

C B

A

Designation Connection from floor

(plinth height 105 mm)Connection in niche (from

centre to connection)Type of connection

A Electrical connection 600 mm K = 160 mm Flush power socket 230 VB Cold water 600 mm N = 170 mm G¾"C Hot water * 600 mm M = 70 mm G¾"D Drain 400 mm L = 110 mm ø 56 mmG1 Dishwasher in base unit Connection in adjacent compartment left and rightG2 Dishwasher in tall unit Connection in max. 2 compartments left and right

* Water connection at >60 °C is not recommended

14

V-ZUG Ltd Planning aid J001.059-12Industriestrasse 66, P.O. Box 59, 6301 ZugTel. +41 58 767 67 67, Fax +41 58 767 61 61

Kitchen appliances03.09.14

[email protected], www.vzug.com

91

Page 92: Planning aid Kitchen appliances - V-ZUG AG · Kitchen appliances 03.09.14 info@vzug.com, 9. 2 Ovens 2.1 Electrical connection data Appliance Country group * Mains connection Fuse

Electrical connection data

Appliance Country group*

Mains connection Rated load Fuse Mains cable

Adora SL (41005-41008, 41042, 41043) A, C, E 230 V~ 50 Hz 3300 W 16 A

1.5 m, withplug

B 2200 W 10 AD 220-240 V~ 50 HzF 3300 W 16 A

Adora S (41010, 41016, 41034-41037) A, B, C, D, E, F 230 V~ 50 Hz 2200 W 10 AAdora N (41011, 41029, 41030-41033)

* Key [➙ see page 2]

Plumbing-in data

For special cases with water hardness in excess of 50 °fH, an external water softener is recommended.

Value Nominal value Minimum MaximumMains pressure (0.1 MPa = 1 bar) Static 0.3–0.4 MPa 0.1 MPa 1.0 MPa

Flowing – 0.08 MPa 1.0 MPaWater hardness – 0.5 °fH 50 °fHWater inlet temperature Cold water – 5 °C 35 °C

Hot water – 40 °C 60 °C

If the water pressure is too high, a pressure reducer valve must be fitted.

Connection example

A1

F

E, C

E, B

D

A2

Designation Adora dishwasherA1 Power socket YesA2 Connection cable Length 1.50 mB Cold water connection YesC Hot water connection YesD Drain hose Length 1.55 m

Internal diameter = 22 mmE Shut-off devices YesF Aqua-stop / water inlet with filter, G¾" Length 1.55 m

14

V-ZUG Ltd Planning aid J001.059-12Industriestrasse 66, P.O. Box 59, 6301 ZugTel. +41 58 767 67 67, Fax +41 58 767 61 61

Kitchen appliances03.09.14

[email protected], www.vzug.com

92

Page 93: Planning aid Kitchen appliances - V-ZUG AG · Kitchen appliances 03.09.14 info@vzug.com, 9. 2 Ovens 2.1 Electrical connection data Appliance Country group * Mains connection Fuse

14.3 Installation summary

Depending on niche height H, either standard or extra height appliances or only one of the two can be installed.

790 800 810 820 830 840 851 860 870 880 890 900 910 920 930 940 950 960

220230240250

S G

210 S S G G

200 S S S G G G

190 S S S S G G G

180 S S S S S G G G

170 S S S S S S

SSSSSS

SSSSSS

SSSSSS

G G G

160 S S S S S S S/G G G G

150 S S S S S S S/G G G G

140 S S S S S S S/G S/G G G G

130 S S S S S S S/G S/G G G G G

120 S S S S S S S/G S/G G G G G G

110 S S S S S S S/G S/G

S/GS/GS/GS/GS/GS/G

S/GS/GS/GS/GS/GS/G

S/GS/GS/GS/GS/GS/G

G G G G G G

107 S S S S S S S/G G G G G G

100 S S S S S S S/G S/G G G G G G G

G

G

G

G

G

G

G

G

G

G

G

G

G

G

G

G

G

G

G

G

G

G

G

G

G

G

G

G

G

G

G

G

G

G

G

G

90 S S S S S S S/G G G G G G G

80 S S S S S S G G G G G G

70 S S S S S G G G G G

60 S S S S G G G G

50 S S S G G G

40 S S G G

30 S G

23 G

S

G

S/G

S/GS/GS/GS/GS/GS/G S/GD

ime

nsio

n A

in

mm

Standard

Extra height

Standard and extra height

Niche height H in mm

H

A

14

V-ZUG Ltd Planning aid J001.059-12Industriestrasse 66, P.O. Box 59, 6301 ZugTel. +41 58 767 67 67, Fax +41 58 767 61 61

Kitchen appliances03.09.14

[email protected], www.vzug.com

93

Page 94: Planning aid Kitchen appliances - V-ZUG AG · Kitchen appliances 03.09.14 info@vzug.com, 9. 2 Ovens 2.1 Electrical connection data Appliance Country group * Mains connection Fuse

14.4 Drilling plans for decor panel 60 cm

61

37

16

9

169

169

576576576

576

582

4 × ø 2.0Depth 12 from rear

8 × ø 2.0Depth 12 from rear

4 × ø 2.0

Integrated Fully integrated Two-part

Depth 12 from rear

(Extr

a h

eig

ht 415)

350

(Extr

a h

eig

ht 415)

(Extr

a h

eig

ht 415)

350

350

14

V-ZUG Ltd Planning aid J001.059-12Industriestrasse 66, P.O. Box 59, 6301 ZugTel. +41 58 767 67 67, Fax +41 58 767 61 61

Kitchen appliances03.09.14

[email protected], www.vzug.com

94

Page 95: Planning aid Kitchen appliances - V-ZUG AG · Kitchen appliances 03.09.14 info@vzug.com, 9. 2 Ovens 2.1 Electrical connection data Appliance Country group * Mains connection Fuse

14.5 Adora SL, S, N with niche width 60 cm

It must be ensured air gap remains in the shadow gap.

Screws and fasteners must be countersunk in the niche. There should be no protruding parts, screw heads, brackets, etc.,otherwise parts of the appliance could become damaged (risk of water damage).

The permissible weights of the front panel / decor system 1 depend on the design variant:

IntegratedNero, white

IntegratedChromeClass

Design integratedMirror glass

Fully integrated

Maximum weight 8 kg 7 kg 6.5 kg 7 kgMinimum weight 5.5 kg 4.5 kg 4 kg 5 kg

• Front panel / decor system (wood) 1 fully integrated must be cut to the necessary dimensions.

For stronger springs, see Accessories Dishwashers [➙ see page 122]

Compensator for ChromeClass and mirror glassCompensator set: See Accessories [➙ see page 106]If the bottom edge of the operating panel Bis not at the same height X as the bottomedge of the adjacent kitchen drawer C, alevelling piece (compensator K) must bemounted (see Installation instructionsJ182.51).

X

B C

K

Compensators contained in the set:8 mm, 12 mm, 16 mm

14

V-ZUG Ltd Planning aid J001.059-12Industriestrasse 66, P.O. Box 59, 6301 ZugTel. +41 58 767 67 67, Fax +41 58 767 61 61

Kitchen appliances03.09.14

[email protected], www.vzug.com

95

Page 96: Planning aid Kitchen appliances - V-ZUG AG · Kitchen appliances 03.09.14 info@vzug.com, 9. 2 Ovens 2.1 Electrical connection data Appliance Country group * Mains connection Fuse

Base unit «standard»

786–867 *

*

21–226

780–861 *

30–100

639–757

1

596 572

585

600

16–22

≥ 580BD

* Up to max. 896 with a second runner only,can be ordered under W82930 ** Up to max. 902 with a second runner only,can be ordered under W82930

Nero, white ChromeClass Mirror glassOperating panel Bincl. compensator

124-146 mm 124-140 mm 124-140 mm

Decor panel D 490-632 mm 496-632 mm 496-632 mm

Size of base gap S.

790 800 810 820 830 840 850 860 870

107107 117

107 117 127117 127 137127 137 147137 147 155

47 57 67 778797

145 155 165

22222222510152330

37 47 57 67 778797

27 37 47 57 67 778797

Min.

Max.

127127 137

107117

127 137 147127 137 147

97107117

157127 137 147 157 167

127 137 147 157

87 97107117

167 177137 147 157 167 177 187147 157 167

77 87 97107117

177 187 197157 167 177 187 197 207167 177

67 77 87 97107117

187 197 207 217175 185 195 205 215 225

880

137147

117127

157167177187197207217227235

890

147157

127137

167177187197207217227237245

900

157167

137147

177187197207217227237247255

57 67 77 87 97107117

Niche height H in mm Min. Sin mm

Dim

ensio

n A

in m

m H30–100

A

S

14

V-ZUG Ltd Planning aid J001.059-12Industriestrasse 66, P.O. Box 59, 6301 ZugTel. +41 58 767 67 67, Fax +41 58 767 61 61

Kitchen appliances03.09.14

[email protected], www.vzug.com

96

Page 97: Planning aid Kitchen appliances - V-ZUG AG · Kitchen appliances 03.09.14 info@vzug.com, 9. 2 Ovens 2.1 Electrical connection data Appliance Country group * Mains connection Fuse

Base unit «extra height»

851–932 *

*

21–226

845–926 *

30–100

704–822

1

596 572

650

600

16–22

≥ 580B

D

* Up to max. 961 with a second runner only,can be ordered under W82930 ** Up to max. 967 with a second runner only,can be ordered under W82930

Nero, white ChromeClass Mirror glassOperating panel Bincl. compensator

124-146 mm 124-140 mm 124-140 mm

Decor panel D 555-697 mm 561-697 mm 561-697 mm

Size of base gap S.

851 860 870 880 890 900 910 920 930

102102 112

103 112 122113 122 132123 132 142133 142 152

42 52 62 728292

141 150 160

22222222510152330

32 42 52 62 728292

23 33 43 53 63 738393

Min.

Max.

122122 132

102112

122 132 142122 132 142

92102112

152122 132 142 152 162

122 132 142 152

82 92102112

162 172132 142 152 162 172 182142 152 162

72 82 92102112

172 182 192152 162 172 182 192 202162 172

62 72 82 92102112

182 192 202 212170 180 190 200 210 220

940

132142

112122

152162172182192202212222230

950

142152

122132

162172182192202212222232240

960

152162

132142

172182192202212222232242250

52 62 72 82 92102112

Niche height H in mm Min. Sin mm

Dim

ensio

n A

in m

m H

30–100

A

S

14

V-ZUG Ltd Planning aid J001.059-12Industriestrasse 66, P.O. Box 59, 6301 ZugTel. +41 58 767 67 67, Fax +41 58 767 61 61

Kitchen appliances03.09.14

[email protected], www.vzug.com

97

Page 98: Planning aid Kitchen appliances - V-ZUG AG · Kitchen appliances 03.09.14 info@vzug.com, 9. 2 Ovens 2.1 Electrical connection data Appliance Country group * Mains connection Fuse

Tall unit «standard»Can also be installed in base unit on base element

Tall unit «extra height»

D

756

757

764

+1

-2

105

596 572

600

501

585

B

3 m

m

C

C Slide plate

12

0

40

D

821

822

829

+1

-2

105

596 572

600

501

650

B

3 m

m

C

Nero, white ChromeClass Mirror glass Nero, white ChromeClass Mirror glassOperating panelB incl. compen-sator

124-146 mm 124-140 mm 124-140 mm Operating panelB incl. compen-sator

124-146 mm 124-140 mm 124-140 mm

Decor panel D 610-632 mm 616-632 mm 616-632 mm Decor panel D 675-697 mm 681-697 mm 681-697 mm

Slide plate for tall unit must be ordered from V-ZUG.

14

V-ZUG Ltd Planning aid J001.059-12Industriestrasse 66, P.O. Box 59, 6301 ZugTel. +41 58 767 67 67, Fax +41 58 767 61 61

Kitchen appliances03.09.14

[email protected], www.vzug.com

98

Page 99: Planning aid Kitchen appliances - V-ZUG AG · Kitchen appliances 03.09.14 info@vzug.com, 9. 2 Ovens 2.1 Electrical connection data Appliance Country group * Mains connection Fuse

Tall unit «extra height» with decor panel and drawer 251 mm

Slide plate for tall unit must be ordered from V-ZUG.

596 572187

600

50

251

829

+1

-2

821

105

650

D

B

757

1

120

40

3 m

m

C

C Slide plateE Removable cover strip

Cross-section of installation variant

60

251

1,5

1016 (

8/6

)

40

D

105

E

Nero, white ChromeClass Mirror glassOperating panel Bincl. compensator

124-146 mm 124-140 mm 124-140 mm

Decor panel D 610-632 mm 616-632 mm 616-632 mm

Installing extra-long decor panel

≥ 100*

H

6

5

E

F

G

* A continuous underside strip is recommended. E WorktopF Continuous underside stripG Decor panelH Niche height

14

V-ZUG Ltd Planning aid J001.059-12Industriestrasse 66, P.O. Box 59, 6301 ZugTel. +41 58 767 67 67, Fax +41 58 767 61 61

Kitchen appliances03.09.14

[email protected], www.vzug.com

99

Page 100: Planning aid Kitchen appliances - V-ZUG AG · Kitchen appliances 03.09.14 info@vzug.com, 9. 2 Ovens 2.1 Electrical connection data Appliance Country group * Mains connection Fuse

15 Dishwashers with heat pump

15.1 General notes

Efficient repairs can only be guaranteed if it is possible to uninstall the whole appliance at any time without causing anydamage.

At any time it must be possible to pull the appliance out of the niche horizontally without dismantling any part of the cabinet.

For work surfaces that are susceptible to moisture, use work surface protection W70163.

General operating conditionsAmbient temperature: min. 10 °C to max. 35 °C

The appliances are designed for use up to a max. altitude of 2000 m above sea level.

15.2 Electrical connection data / plumbing in

40

12

0

K

L M

N

G1

G2

D

C B

A

Designation Connection from floor(plinth height 105 mm)

Connection in niche (fromcentre to connection)

Type of connection

A Electrical connection 600 mm K = 160 mm Flush power socket 230 VB Cold water 600 mm N = 170 mm G¾"C Hot water * 600 mm M = 70 mm G¾"D Drain 400 mm L = 110 mm ø 56 mmG1 Dishwasher in base unit Connection in adjacent compartment left and rightG2 Dishwasher in tall unit Connection in max. 2 compartments left and right

* Water connection at >60 °C is not recommended

15

V-ZUG Ltd Planning aid J001.059-12Industriestrasse 66, P.O. Box 59, 6301 ZugTel. +41 58 767 67 67, Fax +41 58 767 61 61

Kitchen appliances03.09.14

[email protected], www.vzug.com

100

Page 101: Planning aid Kitchen appliances - V-ZUG AG · Kitchen appliances 03.09.14 info@vzug.com, 9. 2 Ovens 2.1 Electrical connection data Appliance Country group * Mains connection Fuse

Electrical connection data

Appliance Country group * Mains connection Rated load Fuse Mains cableAdora SL WP (41009,41038)

A, C, E 230 V~ 50 Hz 3300 W 16 A 1.5 m, with plugB 2200 W 10 A

D 220-240 V~ 50 HzF 3300 W 16 A

* Key [➙ see page 2]

Plumbing-in data

For special cases with water hardness in excess of 50 °fH, an external water softener is recommended.

Value Nominal value Minimum MaximumMains pressure (0.1 MPa = 1 bar) Static 0.3–0.4 MPa 0.1 MPa 1.0 MPa

Flowing – 0.08 MPa 1.0 MPaWater hardness – 0.5 °fH 50 °fHWater inlet temperature – 5 °C 60 °C

Connection example

A1

F

E, C

E, B

D

A2

Designation Adora dishwasherA1 Power socket YesA2 Connection cable Length 1.50 mB Cold water connection YesC Hot water connection YesD Drain hose Length 1.55 m

Internal diameter = 22 mmE Shut-off devices Yes, ¾"F Aqua-stop / water inlet with filter, G¾" Length 1.55 m

15

V-ZUG Ltd Planning aid J001.059-12Industriestrasse 66, P.O. Box 59, 6301 ZugTel. +41 58 767 67 67, Fax +41 58 767 61 61

Kitchen appliances03.09.14

[email protected], www.vzug.com

101

Page 102: Planning aid Kitchen appliances - V-ZUG AG · Kitchen appliances 03.09.14 info@vzug.com, 9. 2 Ovens 2.1 Electrical connection data Appliance Country group * Mains connection Fuse

15.3 Installation summary

Keep base compartment unobstructed, appliance stands on the floor.

Size of base gap S.

870 880 890 900 910

200190180170160150140130120110105

S

SSSSSS

SSSSSS

SSSSSS

SSSSSS

SSSSSS

S

Standard without cabinet plinth

H

A

Niche height H in mm

Dim

en

sio

n A

in

mm

15.4 Drilling plans for decor panel 60 cm

61

37

169

169

169

576576576

576

582

4 × ø 2.0 8 × ø 2.0

4 × ø 2.0

350

350

350

Depth 12 from rear Depth 12 from rear Depth 12 from rear

Integrated Fully integrated Two-part

15

V-ZUG Ltd Planning aid J001.059-12Industriestrasse 66, P.O. Box 59, 6301 ZugTel. +41 58 767 67 67, Fax +41 58 767 61 61

Kitchen appliances03.09.14

[email protected], www.vzug.com

102

Page 103: Planning aid Kitchen appliances - V-ZUG AG · Kitchen appliances 03.09.14 info@vzug.com, 9. 2 Ovens 2.1 Electrical connection data Appliance Country group * Mains connection Fuse

15.5 Adora SL WP with niche width 60 cm

It must be ensured air gap remains in the shadow gap.

Screws and fasteners must be countersunk in the niche. There should be no protruding parts, screw heads, brackets, etc.,otherwise parts of the appliance could become damaged (risk of water damage).

At any time it must be possible to pull the appliance out of the niche horizontally without dismantling any part of the cabinet.

The permissible weights of the front panel / decor system 1 depend on the design variant:

IntegratedNero, white

IntegratedChromeClass

Design integratedMirror glass

Fully integrated

Maximum weight 8 kg 7 kg 6.5 kg 7 kgMinimum weight 5.5 kg 4.5 kg 4 kg 5 kg

• Front panel / decor system (wood) 1 fully integrated must be cut to the necessary dimensions.

For stronger springs, see Accessories Dishwashers [➙ see page 122]

Compensator for ChromeClass and mirror glassCompensator set: see Accessories Dishwashers [➙ see page 122]If the bottom edge of the operating panel Bis not at the same height X as the bottomedge of the adjacent kitchen drawer C, alevelling piece (compensator K) must bemounted (see Installation instructionsJ182.51).

X

B C

K

Compensators contained in the set:8 mm, 12 mm, 16 mm

15

V-ZUG Ltd Planning aid J001.059-12Industriestrasse 66, P.O. Box 59, 6301 ZugTel. +41 58 767 67 67, Fax +41 58 767 61 61

Kitchen appliances03.09.14

[email protected], www.vzug.com

103

Page 104: Planning aid Kitchen appliances - V-ZUG AG · Kitchen appliances 03.09.14 info@vzug.com, 9. 2 Ovens 2.1 Electrical connection data Appliance Country group * Mains connection Fuse

Base element

870–

910 *

10

5–26

5

86

7–90

7

30–100

63

9–757

1

596 572

585

600

16–22

≥ 580BD

* If the niche height is greater than 910 mm,a plate must be placed underneath the appli-ance or an extra-long decor panel must beused.

Mirror glass Fully integratedOperating panel Bincl. compensator

124-140 mm -

Decor panel D 496-632 mm 639-757

Size of base gap S.

870

222222225

10152330

Min.

Max.

127137

107117

147157167177187197207217225

880

137147

117127

157167177187197207217227235

890

147157

127137

167177187197207217227237245

900

157167

137147

177187197207217227237247255

910

167177

147157

187197207217227237247257265

Min. Sin mm

Niche height H in mm

Dim

ensio

n A

in m

m

H

30–100

A

S

15

V-ZUG Ltd Planning aid J001.059-12Industriestrasse 66, P.O. Box 59, 6301 ZugTel. +41 58 767 67 67, Fax +41 58 767 61 61

Kitchen appliances03.09.14

[email protected], www.vzug.com

104

Page 105: Planning aid Kitchen appliances - V-ZUG AG · Kitchen appliances 03.09.14 info@vzug.com, 9. 2 Ovens 2.1 Electrical connection data Appliance Country group * Mains connection Fuse

Tall unit «standard»

A

D

86

7

75

7

87

0

38

1

+1

-2

10

5

596 572

600

≥ 580

1

585

B

12

0

40

Cross-sectionInstallation example

1,5

10

16

(8

/6)

40

D

10

5

C

19

12

7

3

C Removable lower front panel (251)

Niche floor A

G

• Load-bearing capacity of niche floor A: 100 kg

• Given a load of 75 kg per appliance foot G, the niche floor may sag by a max. of 1 mm.

Mirror glassOperating panel Bincl. compensator

124-140 mm

Decor panel D 616-632 mm

Installing extra-long decor panel

≥ 100*

H

6

5

E

F

G

* A continuous underside strip is recommended. E WorktopF Continuous underside stripG Decor panelH Niche height

15

V-ZUG Ltd Planning aid J001.059-12Industriestrasse 66, P.O. Box 59, 6301 ZugTel. +41 58 767 67 67, Fax +41 58 767 61 61

Kitchen appliances03.09.14

[email protected], www.vzug.com

105

Page 106: Planning aid Kitchen appliances - V-ZUG AG · Kitchen appliances 03.09.14 info@vzug.com, 9. 2 Ovens 2.1 Electrical connection data Appliance Country group * Mains connection Fuse

16 Accessories

16.1 Control set option (current sensor module with relay module)57

57

94 94

94 180

The control set option serves to control external devices (such as a fan) by a control signal generated by a V-ZUG appliance. Theelectrical properties of both component parts must be known for an effective interface. This requires special clarification andassumes electrotechnical expertise. Planning and installation must therefore only be carried out by an electrotechnical expert.

For 230 V~/max. 16 A:

Article no. For 400 V 3N~/max. 25 A:

Article no.

Control set option SSM230 P60036 Control set option SSM400 P60037comprised of: comprised of: 1 current sensor module cpl. SSM1 P60031 1 current sensor module cpl. SSM2 P600321 relay module cpl. RM P60033 1 relay module cpl. RM P60033

The example connection below shows a standard situation. For detailed planning, refer to document P60.008 which can be obtainedfrom the Head Office in Zug, Tel. + 41 58 767 67 67, or on the Internet from www.vzug.ch.

Power supply system

appliance

e.g. 400 V 2N~

400 V 3N~

Power supply system

external consumer

230 V~

Current sensor module (current transformer)

SSM1 / SSM2

RM

Relay module (control unit)

V-ZUG

appliance

External

consumer

e.g. ventialtion

16

V-ZUG Ltd Planning aid J001.059-12Industriestrasse 66, P.O. Box 59, 6301 ZugTel. +41 58 767 67 67, Fax +41 58 767 61 61

Kitchen appliances03.09.14

[email protected], www.vzug.com

106

Page 107: Planning aid Kitchen appliances - V-ZUG AG · Kitchen appliances 03.09.14 info@vzug.com, 9. 2 Ovens 2.1 Electrical connection data Appliance Country group * Mains connection Fuse

16.2 Cookers / ovens / steam cookers / microwaves / coffee machines / warming & systems drawers

Compensation elements

Ventilation grille• Ventilation grilles are needed when glass ceramic hobs are installed above ovens.

• For installation, see installation instructions J402.54.

Niche width 60 cmInstallation above the control panel

35

597 Construction types EURO60-600Short oven without drawerArticle no.H63161 (white)H63163 (nero)H63165 (ChromeClass)

Adapter frame• For installation, see installation instructions J731.050.

Niche width 60 cmInstallation below the appliance

Construction types EURO 60-600

Short ovenwithout drawer

48019.53

5

596

560 60-381Mini oven

Article no.K48135 (ChromeClass)K38134 (glass)

Mounting angle for combination possibilities (art. no. K20198)

• For installation, see installation instructions J337.050.

In the niche mount to the wood left and right.

The appliance is placed on the mounting angle and pushed into theniche.

Front of unit

16

V-ZUG Ltd Planning aid J001.059-12Industriestrasse 66, P.O. Box 59, 6301 ZugTel. +41 58 767 67 67, Fax +41 58 767 61 61

Kitchen appliances03.09.14

[email protected], www.vzug.com

107

Page 108: Planning aid Kitchen appliances - V-ZUG AG · Kitchen appliances 03.09.14 info@vzug.com, 9. 2 Ovens 2.1 Electrical connection data Appliance Country group * Mains connection Fuse

Design coverThe design cover covers the intermediate base for EURO niches and is fora combined installation of two appliances e.g. oven 1 and combi-steam 2.The cover is dimensioned for panel overlapping of 4 mm.

• For installation, see installation instructions J340.050.

• Depending on the thickness of the intermediate base b, two variants(nero) of the design cover A are available:

Article no.K37158 (b = 16 mm / a = 10.5 mm)K37159 (b = 19 mm / a = 13.5 mm)

b

aA

1

2

16

V-ZUG Ltd Planning aid J001.059-12Industriestrasse 66, P.O. Box 59, 6301 ZugTel. +41 58 767 67 67, Fax +41 58 767 61 61

Kitchen appliances03.09.14

[email protected], www.vzug.com

108

Page 109: Planning aid Kitchen appliances - V-ZUG AG · Kitchen appliances 03.09.14 info@vzug.com, 9. 2 Ovens 2.1 Electrical connection data Appliance Country group * Mains connection Fuse

16.3 Glass ceramic hobs

Designation Article no. Installation instructionsThermal shielding plate set for Toptronic appliances- GK25TE…- GK45TEBS.1, GK45TEBS.1C, GK45TEBS.2F- GK45TEAS, GK45TEASC, GK45TEAS.1F- GK45TEPS, GK45TEPSC, GK45TEPSF- GK35TEPS…

H62542H62622H62617H62616H63266

J402.70

Ventilation protective plate set for installation below induction hobs(Not possible for wok and induction appliances with dial controls)Niche width 600 mmNiche width 825 mmNiche width 900 mm

H61083H61084H61085 J402.48

Niche width 600 mm without sealNiche width 825 mm without sealNiche width 900 mm without seal

H61087H61088H61089

Ventilation grille, height 35 mmfor built-under short ovensType of construction 60-600- White- Nero- ChromeClass- ChromeClass (TouchClean)

H63161H63163H63165H63256

J402.54

Type of construction 60-450- Nero- ChromeClass- ChromeClass (TouchClean)

H60039H60041H60053

J402.50

Type of construction 60-381- Nero- ChromeClass- ChromeClass (TouchClean)

H60033H60035H60049

J402.52

16

V-ZUG Ltd Planning aid J001.059-12Industriestrasse 66, P.O. Box 59, 6301 ZugTel. +41 58 767 67 67, Fax +41 58 767 61 61

Kitchen appliances03.09.14

[email protected], www.vzug.com

109

Page 110: Planning aid Kitchen appliances - V-ZUG AG · Kitchen appliances 03.09.14 info@vzug.com, 9. 2 Ovens 2.1 Electrical connection data Appliance Country group * Mains connection Fuse

Designation Article no. Installation instructionsAngle set for flush mounted installation with straight stone cut- Hob size 30- Hob size 40- Hob size 60- Hob size 70- Hob size 80- Hob size 90- Hob size 80 Panorama- Hob size 90 Panorama Appropriate adhesive for mounting in stone worktops: Permabond F246, incl. activator, 50 ml tube. From Silitech AG, 3008 Bern.

H63770H63771H63772H63773H63774H63775H62679H62568

B11502

Sealing strip set for flush installationTeppan Yaki (GK16TIYS.1F, GK26TIYS.2F)Other hobs

H62695H62142

J31008.120J004.130

Adjusting brace set for mounting in glass worktopsAdjusting brace set H62510 J416.99

Intermediate support sets for combined installationIntermediate support set for gas (1×) H64140 Intermediate support set for induction (2×) H63789

Cement set for flush installationCement set 86392885 J004.130

Suitable for all absorbent worktop materials (wood and natural stones such as marble, granite).

The set comprises:

Designation Remarks NumberCleaning agent, type T * – 1Spezialprimer Typ 1105 * Flasche à 100 ml

1

Silicon adhesive, black cartridge with nozzle

1

For the remaining, resp. for non-absorbent and artificial stone surfaces, the special primer type 107 *, art. no. 45.2771.76 must beused. Not suitable for polyethylene, polypropylene or Teflon.

* Primer types: Firm name H. OTTO GmbH u. Co., Chemie GK, D-83413 Fridolfing

Good adhesion cannot be obtained on slate or other materials containing oil. The use of such worktop materials is not advised for theflush installation of glass ceramic hobs.

In case of doubt as to the suitablity of cement set materials, especially when using them for the first time, we recommendthat you carry out adhesion trials on test pieces or at non-visible locations.

16

V-ZUG Ltd Planning aid J001.059-12Industriestrasse 66, P.O. Box 59, 6301 ZugTel. +41 58 767 67 67, Fax +41 58 767 61 61

Kitchen appliances03.09.14

[email protected], www.vzug.com

110

Page 111: Planning aid Kitchen appliances - V-ZUG AG · Kitchen appliances 03.09.14 info@vzug.com, 9. 2 Ovens 2.1 Electrical connection data Appliance Country group * Mains connection Fuse

16.4 Range hoods

Technical information on the range hoods can be found in the document J328.36 «TechInfo for range hoods» and the pricelist.

Short exhaust air connectionThe exhaust air connection is used for exceptionally low installation heights, e.g. in older properties. Depending on how it is installed,the air resistance can be 30-40 % higher than with the proposed exhaust air connection. This must be taken into account in thedimensioning of the exhaust air piping.

Article no.H41877

The exhaust air connection can be used for the following models:

• DF-E5, DF-E6

• DF-SG5, DF-SG6, DF-SG8, DF-SG9

• DF-SLG5, DF-SLG6, DF-SLG8, DF-SLG9

Protective plate for side wallsThe protective plates for the side walls are needed to protect the sides of the wall unit from grease and moisture.

x

Designation Dimensions(height × depth)

Wall unit depth x Colour Article no.

Protective plate for side walls 235 × 310 mm 330 mm White K26092Protective plate for side walls 235 × 310 mm 330 mm Nero K26093Protective plate for side walls 235 × 310 mm 330 mm ChromeClass K26094Protective plate for side walls 235 × 330 mm 350 mm White H42792Protective plate for side walls 235 × 330 mm 350 mm Nero H42791Protective plate for side walls 235 × 330 mm 350 mm ChromeClass H42790Protective plate for side walls 235 × 350 mm 370 mm White H42795Protective plate for side walls 235 × 350 mm 370 mm Nero H42794Protective plate for side walls 235 × 350 mm 370 mm ChromeClass H42793

16

V-ZUG Ltd Planning aid J001.059-12Industriestrasse 66, P.O. Box 59, 6301 ZugTel. +41 58 767 67 67, Fax +41 58 767 61 61

Kitchen appliances03.09.14

[email protected], www.vzug.com

111

Page 112: Planning aid Kitchen appliances - V-ZUG AG · Kitchen appliances 03.09.14 info@vzug.com, 9. 2 Ovens 2.1 Electrical connection data Appliance Country group * Mains connection Fuse

Helically wound pipes

Helically wound pipe Description

d1

Strong, helically wound pipe, sendzimir galvanizedMaterial thickness 0.5 mm1× à 3 m

Article no. d1H42028 ø 125 mmH42029 ø 150 mm

Fastening elements

Pipe clip with thread

M8 (M10)

d1

1/2" (3/4") DescriptionFor mounting the helically wound pipe2-piece set with sound insulation insert, incl. screws and nutsGalvanized steelThread M8

Article no. d1H42049 ø 125 mmH42050 ø 150 mm

Double-threaded pin M8, galvanizedDescriptionFor mounting the pipe clip in the concrete wallLength 40 mm

Article no. H42057

Quick-locking hose clamp

Article no. 33121304 ø 110-130 mm33121336 ø 150 mm

16

V-ZUG Ltd Planning aid J001.059-12Industriestrasse 66, P.O. Box 59, 6301 ZugTel. +41 58 767 67 67, Fax +41 58 767 61 61

Kitchen appliances03.09.14

[email protected], www.vzug.com

112

Page 113: Planning aid Kitchen appliances - V-ZUG AG · Kitchen appliances 03.09.14 info@vzug.com, 9. 2 Ovens 2.1 Electrical connection data Appliance Country group * Mains connection Fuse

Connecting nipples / connecting pipes

Connecting nipple

d1

L

DescriptionSendzimir galvanized sheet steel L = 80 mm

Article no. d1H42030 ø 125 mmH42031 ø 150 mmH40169 ø 160 mm

Connecting pipe

d1

L

DescriptionSendzimir galvanized sheet steel L = 90 mm

Article no. d1H42032 ø 125 mmH412033 ø 150 mm

Cladding elbow

Cladding elbow

d140

d1

45

Formwork

DescriptionFor installation on formworkSpecially for inlays in concrete ceilingSendzimir galvanized sheet steel

Article no. d1H42038 ø 125 mmH42039 ø 150 mm

16

V-ZUG Ltd Planning aid J001.059-12Industriestrasse 66, P.O. Box 59, 6301 ZugTel. +41 58 767 67 67, Fax +41 58 767 61 61

Kitchen appliances03.09.14

[email protected], www.vzug.com

113

Page 114: Planning aid Kitchen appliances - V-ZUG AG · Kitchen appliances 03.09.14 info@vzug.com, 9. 2 Ovens 2.1 Electrical connection data Appliance Country group * Mains connection Fuse

Elbows

Elbow 90°

R

d1

DescriptionElbow, pressedUse with flexible and rigid pipesSendzimir galvanized sheet steelR = d1

Article no. d1H42034 ø 125 mmH42036 ø 150 mm

Elbow 45°

R

d1 DescriptionElbow, pressedUse with flexible and rigid pipesSendzimir galvanized sheet steelR = d1

Article no. d1H42035 ø 125 mmH42037 ø 150 mm

Reducers

Reducer

d1 d2

L

DescriptionPressed versionSendzimir galvanized sheet steel L = 22 mm

Article no. d1-d2H42040 ø 150-125 mm

16

V-ZUG Ltd Planning aid J001.059-12Industriestrasse 66, P.O. Box 59, 6301 ZugTel. +41 58 767 67 67, Fax +41 58 767 61 61

Kitchen appliances03.09.14

[email protected], www.vzug.com

114

Page 115: Planning aid Kitchen appliances - V-ZUG AG · Kitchen appliances 03.09.14 info@vzug.com, 9. 2 Ovens 2.1 Electrical connection data Appliance Country group * Mains connection Fuse

Tee pieces

Tee 45°

40 d3

d1

L

DescriptionUse with flexible and rigid pipesFlow-enhancingSendzimir galvanized sheet steel L = 300 mmd3 = 125 mm

Article no. d1H42042 ø 150 mm

Y-pipes

45° y-pipe

L

d3d4

d1

45˚45˚

DescriptionUse with flexible and rigid pipesSendzimir galvanized sheet steel L = d1 = 150 mmd3 = 125 mmd4 = 100 mm

Article no. d1H42045 ø 150 mm

30° y-pipe

L

d3d4

d1

30˚30˚

DescriptionUse with flexible and rigid pipesSendzimir galvanized sheet steel L = d1 = 150 mmd3 = 125 mmd4 = 100 mm

Article no. d1H42046 ø 150 mm

16

V-ZUG Ltd Planning aid J001.059-12Industriestrasse 66, P.O. Box 59, 6301 ZugTel. +41 58 767 67 67, Fax +41 58 767 61 61

Kitchen appliances03.09.14

[email protected], www.vzug.com

115

Page 116: Planning aid Kitchen appliances - V-ZUG AG · Kitchen appliances 03.09.14 info@vzug.com, 9. 2 Ovens 2.1 Electrical connection data Appliance Country group * Mains connection Fuse

Pipe end pieces

Pipe end piece

d1

DescriptionConnection with grilleSendzimir galvanized sheet steel

Article no. d1H42047 ø 125 mmH42048 ø 150 mm

Weather protection grilles

Weather protection grille

d1

L DescriptionWeather protection grille without a non-return flap valve, round,pressed, made from aluminiumWith fly screen and connection piece L = 45 mm

Article no. d1H42063 ø 125 mmH42064 ø 150 mm

Weather protection grille made from plastic

d1 20

0

L

200

DescriptionWeather protection grille without a non-return flap valve, squarewith connection pieceWeatherproof L = 40 mm

Article no. d1H42058 White, ø 125 mmH42059 Beige, ø 125 mmH42060 Brown, ø 125 mmH42080 White, ø 150 mmH42081 Beige, ø 150 mmH42082 Brown, ø 150 mm

16

V-ZUG Ltd Planning aid J001.059-12Industriestrasse 66, P.O. Box 59, 6301 ZugTel. +41 58 767 67 67, Fax +41 58 767 61 61

Kitchen appliances03.09.14

[email protected], www.vzug.com

116

Page 117: Planning aid Kitchen appliances - V-ZUG AG · Kitchen appliances 03.09.14 info@vzug.com, 9. 2 Ovens 2.1 Electrical connection data Appliance Country group * Mains connection Fuse

Wall pipes

Telescopic wall pipe with non-return flap valve

d1

L Description3-partSendzimir galvanized sheet steelGrille made from aluminium; can be painted L = Wall thickness 300-460 mm

Article no. d1H42065 ø 125 mmH42066 ø 150 mm

Flaps

Non-return flap valve with sealing lip

L

d1

DescriptionMade from robust sheet steelFor flexible and rigid pipes L = 80 mm

Article no. d1H42061 ø 125 mmH42062 ø 150 mm

Motor flap, complete, 230V

d1

21

0

80

DescriptionConsisting of motor, flap lever and regulating flap with gasketSendzimir galvanized sheet steel

Article no. d1H43390 ø 125 mmH43391 ø 150 mm

16

V-ZUG Ltd Planning aid J001.059-12Industriestrasse 66, P.O. Box 59, 6301 ZugTel. +41 58 767 67 67, Fax +41 58 767 61 61

Kitchen appliances03.09.14

[email protected], www.vzug.com

117

Page 118: Planning aid Kitchen appliances - V-ZUG AG · Kitchen appliances 03.09.14 info@vzug.com, 9. 2 Ovens 2.1 Electrical connection data Appliance Country group * Mains connection Fuse

Hoses

Aluminium hose, semi-flexible Description

d1

Round Aluflex, semi-flexibleDimensionally stable, flame resistant1× à 3 m

Article no. d1H42051 ø 125 mmH42052 ø 150 mmH40168 ø 160 mm

Aluminium hose, highly flexible Description

d1

Round Aluflex, highly flexibleInternal bending radius 30-60 mmDimensionally stable, flame resistant1× à 10 m

Article no. d1H42053 ø 125 mm16955803 ø 150 mm

Aluminium hose, insulated Description

d1

Round Aluflex, highly flexibleSound-insulating 25 mm1× à 10 m

Article no. d1H42055 ø 125 mmH42056 ø 150 mm

Rectangular aluminium hose

54

140/180

DescriptionAluflex, highly flexibleReinforced with 2 layers of polyester and 3 layers of aluminiumFlame resistantOnly suitable for short exhaust ductsPay attention to back pressure.1× à 10 m

Article no. d1H42083 54 × 140 mm (ø 125 mm)H42084 54 × 180 mm (ø 150 mm)

16

V-ZUG Ltd Planning aid J001.059-12Industriestrasse 66, P.O. Box 59, 6301 ZugTel. +41 58 767 67 67, Fax +41 58 767 61 61

Kitchen appliances03.09.14

[email protected], www.vzug.com

118

Page 119: Planning aid Kitchen appliances - V-ZUG AG · Kitchen appliances 03.09.14 info@vzug.com, 9. 2 Ovens 2.1 Electrical connection data Appliance Country group * Mains connection Fuse

Flat channels

Flat channel

82

254L

DescriptionExhaust ducting system with very low installation height of 82 mmSendzimir galvanized sheet steelCorresponds to nominal diameter ø of 150 mm

Article no. H42068 L = 1000 mmH42069 L = 600 mm

Reinforced flat channel

82

254L

DescriptionExhaust ducting system with very low installation height of 82 mmSendzimir galvanized sheet steelWith reinforcement for concreting inCorresponds to nominal diameter ø of 150 mm

Article no. H42085 L = 600 mmH42086 L = 1000 mm

Telescopic flat channel

254L

82

DescriptionExhaust ducting system with very low installation height of 82 mmSendzimir galvanized sheet steelCorresponds to nominal diameter ø of 150 mm

Article no. H42070 L = 275-535 mm

Reinforcing rib for flat channel

L

DescriptionFor concreting in flat channel

Article no. H42071 L = 600 mmH42072 L = 1000 mm

Mounting bracket for flat channel

257

82

Article no. H42073

16

V-ZUG Ltd Planning aid J001.059-12Industriestrasse 66, P.O. Box 59, 6301 ZugTel. +41 58 767 67 67, Fax +41 58 767 61 61

Kitchen appliances03.09.14

[email protected], www.vzug.com

119

Page 120: Planning aid Kitchen appliances - V-ZUG AG · Kitchen appliances 03.09.14 info@vzug.com, 9. 2 Ovens 2.1 Electrical connection data Appliance Country group * Mains connection Fuse

Elbow 90°, vertical, for flat channel

14

0

254

82

Article no. H42074

Elbow 45°, vertical, for flat channel

16

0

254

82

Article no. H42075

Elbow 90°, horizontal, for flat channel

254

315

82

Article no. H42076

Elbow 45°, horizontal, for flat channel

254

280

82

Article no. H42077

16

V-ZUG Ltd Planning aid J001.059-12Industriestrasse 66, P.O. Box 59, 6301 ZugTel. +41 58 767 67 67, Fax +41 58 767 61 61

Kitchen appliances03.09.14

[email protected], www.vzug.com

120

Page 121: Planning aid Kitchen appliances - V-ZUG AG · Kitchen appliances 03.09.14 info@vzug.com, 9. 2 Ovens 2.1 Electrical connection data Appliance Country group * Mains connection Fuse

Transition piece for flat channel

14

5

254

82

d1 DescriptionFor transitioning from round to flat

Article no. H42078

Diverter piece on flat channel

60

82

115

200 254

Article no. H42087 Connection ø 125 mmH42079 Connection ø 150 mm

Flat channel wall box

150

150300

DescriptionWith non-return flap valve and weather protection grille

Article no. H42054

Sealing tape

Aluminium tapeDescriptionFabric-reinforced tape, with protective film50 mm × 50 m roll

Article no. H42067

16

V-ZUG Ltd Planning aid J001.059-12Industriestrasse 66, P.O. Box 59, 6301 ZugTel. +41 58 767 67 67, Fax +41 58 767 61 61

Kitchen appliances03.09.14

[email protected], www.vzug.com

121

Page 122: Planning aid Kitchen appliances - V-ZUG AG · Kitchen appliances 03.09.14 info@vzug.com, 9. 2 Ovens 2.1 Electrical connection data Appliance Country group * Mains connection Fuse

16.5 Refrigerators

Designation Article no. RemarksSupplementary kit 60 cm (filler strip)- KFi, KRi, KLi, KIi- KCi, KNi, KPRPieco, KPRieco, KPRi, KCLi

H71755H71756

Length 1530 mmLength 1780 mm

Bottle rack- KMi 60 eco

H72731

16.6 Dishwashers

Adora

Stainless steel fronts (option)Integrated Width Height Depth Article no.Decor set 60 standard ChromeClass 596 mm 632 mm 20 mm W83523Decor set 60 extra height ChromeClass 596 mm 697 mm 20 mm W83524

Mirror glass fronts (option)Integrated Width Height Depth Article no.Decor set 60 standard mirror glass 596 mm 632 mm 20 mm W83526Decor set 60 extra height mirror glass 596 mm 697 mm 20 mm W83527

Diverse setsSet Article no. RemarksConversion kit for slide plate W83583 In place of the plinth runners, for the installation on a plinth or for the tall

unit.Installation set, fully integrated, two-part W83931 For a two-part, fully integrated decor front panel.Compensator set, ChromeClass W81302 Supplied for «ChromeClass» appliances.Compensator set, black W82043 Additional order for «Mirror glass» appliances.

The set can also be used for «ChromeClass» appliances.Plinth runner W82930 For height compensation in a nicheWork surface protection W70163 Protection against escaping moistureCS set containing strong spring W84603 For heavier decor panels, standard height, weight of decor panel max.

10.5 kgCS set containing strong spring W84604 For heavier decor panels, extra height, weight of decor panel max.

10.5 kgCS set containing long hoses SL W86140 Conversion to 3 m Aqua-Stop and 3 m drain hose*CS set containing long hoses N/S W86139 Conversion to 3 m Aqua-Stop and 3 m drain hose*

* The conversion should be carried out by trained personnel only.

16

V-ZUG Ltd Planning aid J001.059-12Industriestrasse 66, P.O. Box 59, 6301 ZugTel. +41 58 767 67 67, Fax +41 58 767 61 61

Kitchen appliances03.09.14

[email protected], www.vzug.com

122

Page 123: Planning aid Kitchen appliances - V-ZUG AG · Kitchen appliances 03.09.14 info@vzug.com, 9. 2 Ovens 2.1 Electrical connection data Appliance Country group * Mains connection Fuse

Notes

V-ZUG Ltd Planning aid J001.059-12Industriestrasse 66, P.O. Box 59, 6301 ZugTel. +41 58 767 67 67, Fax +41 58 767 61 61

Kitchen appliances03.09.14

[email protected], www.vzug.com

123

Page 124: Planning aid Kitchen appliances - V-ZUG AG · Kitchen appliances 03.09.14 info@vzug.com, 9. 2 Ovens 2.1 Electrical connection data Appliance Country group * Mains connection Fuse

V-ZUG Ltd Planning aid J001.059-12Industriestrasse 66, P.O. Box 59, 6301 ZugTel. +41 58 767 67 67, Fax +41 58 767 61 61

Kitchen appliances03.09.14

[email protected], www.vzug.com

124

Page 125: Planning aid Kitchen appliances - V-ZUG AG · Kitchen appliances 03.09.14 info@vzug.com, 9. 2 Ovens 2.1 Electrical connection data Appliance Country group * Mains connection Fuse

V-ZUG Ltd Planning aid J001.059-12Industriestrasse 66, P.O. Box 59, 6301 ZugTel. +41 58 767 67 67, Fax +41 58 767 61 61

Kitchen appliances03.09.14

[email protected], www.vzug.com

125

Page 126: Planning aid Kitchen appliances - V-ZUG AG · Kitchen appliances 03.09.14 info@vzug.com, 9. 2 Ovens 2.1 Electrical connection data Appliance Country group * Mains connection Fuse

Index

AAccessories ..........................................................................106

Adapter frame ............................................................... 107Compensation elements for combination possibilities .. 107Design cover ................................................................. 108for cookers, ovens, steam cookers, microwaves .......... 107for glass ceramic hobs .................................................. 109for range hoods ............................................................. 111for refrigerators .............................................................. 122

Adapter frame ......................................................................107Adjusting brace set ..............................................................110Air outlet cassette (LAC) ........................................................86Air recycling cassette (LRC) ..................................................86Ancillary equipment

Control set option .......................................................... 106Angle set ..............................................................................110

BBuilt-in hoods .........................................................................77

CCement set ...........................................................................110Coffee machines

Accessories ................................................................... 107Combination possibilities

Ovens .............................................................................. 11Steam cookers ................................................................ 16

Compensation elementsAdapter frame ............................................................... 107Design cover ................................................................. 108Mounting angle for combination possibilities ................. 107Ventilation grille ............................................................. 107

Compensator .........................................................................95Control set option .................................................................106Controlling external devices .................................................106Cookers

Accessories ................................................................... 107Country groups ........................................................................2Current sensor module with relay module ...........................106

DDesign cover ........................................................................108Dishwashers

Accessories ................................................................... 122Compensator ................................................................... 95Electrical connection data ............................................... 92Plumbing-in data ............................................................. 92

Dishwashers with heat pump ...............................................100Compensator ................................................................. 103Electrical connection data ............................................. 101Plumbing-in data ........................................................... 101

EElectrical connection data

Adora dishwashers .................................................. 91, 100Ovens .............................................................................. 10Toptronic hobs ................................................................ 46Warming and system drawers ......................................... 19

Electrical connectionsGeneral operating conditions ............................................ 5Steam cookers ................................................................ 12

Electrical connections and installation dimensions ..................5Exhaust air connection .........................................................111

FFrequency stability ...................................................................5Frequency variation .................................................................5Front dimensions of the appliances

Manufacturing tolerance .................................................... 9

GGeneral operating conditions ...................................................5Glass ceramic hobs

Accessories ................................................................... 109Examples for combined installation ................................. 59Hobs for the replacement market .................................... 53Induction hobs ................................................................. 28Toptronic hobs ................................................................ 46

HHeatable appliance drawers ..................................................19Hobs

Accessories ................................................................... 107

IInduction hobs ........................................................................28Induction woks .......................................................................28Installation dimensions .............................................................5

Front dimensions ............................................................... 9Island hoods ...........................................................................69

MMicrowaves

Accessories ................................................................... 107Mounting angle for combination possibilities .......................107

OOperating conditions

General ............................................................................. 5Ovens

Accessories ................................................................... 107Combination possibilities ................................................. 11Electrical connection data ............................................... 10

PPlumbing in

Adora dishwashers .................................................. 91, 100Positions of electrical connections

Range hoods ................................................................... 72

V-ZUG Ltd Planning aid J001.059-12Industriestrasse 66, P.O. Box 59, 6301 ZugTel. +41 58 767 67 67, Fax +41 58 767 61 61

Kitchen appliances03.09.14

[email protected], www.vzug.com

126

Page 127: Planning aid Kitchen appliances - V-ZUG AG · Kitchen appliances 03.09.14 info@vzug.com, 9. 2 Ovens 2.1 Electrical connection data Appliance Country group * Mains connection Fuse

RRange hoods ..........................................................................68

Air outlet cassette (LAC) ................................................. 86Air recycling cassette (LRC) ............................................ 86Built-in hoods .................................................................. 77Cladding elbow .............................................................. 113Connecting nipples ........................................................ 113Connecting pipes ........................................................... 113Elbow ............................................................................ 114Exhaust air connection .................................................. 111Fastening elements ....................................................... 112Flaps ............................................................................. 117Flat channels ................................................................. 119Helically wound pipes .................................................... 112Hoses ............................................................................ 118Island hoods .................................................................... 69Pipe end pieces ............................................................. 116Positions of electrical connections .................................. 72Reducers ....................................................................... 114Sealing tape .................................................................. 121TechInfo for range hoods .............................................. 111Tee pieces ..................................................................... 115Wall hoods ...................................................................... 72Wall pipes ...................................................................... 117Weather protection grilles .............................................. 116Y-pipes .......................................................................... 115

Refrigerators ..........................................................................87

SSealing strip set ...................................................................110Steam cookers .......................................................................12

Accessories ................................................................... 107Installation ....................................................................... 14plumbing in ...................................................................... 15

Supplementary documents ......................................................2TechInfo for range hoods .............................................. 111

Symbols used ..........................................................................2System drawers .....................................................................19

Accessories ................................................................... 107

TTechInfo for range hoods .....................................................111Thermal shielding plate set ..................................................109Toptronic hobs .......................................................................46

UUse at altitude ..........................................................................5

VValidity .....................................................................................5Ventilation grille ............................................................107, 109Ventilation protective plate set .............................................109

WWall hoods .............................................................................72Warming and system drawers

Electrical connection data ............................................... 19Warming drawers

Accessories ................................................................... 107

V-ZUG Ltd Planning aid J001.059-12Industriestrasse 66, P.O. Box 59, 6301 ZugTel. +41 58 767 67 67, Fax +41 58 767 61 61

Kitchen appliances03.09.14

[email protected], www.vzug.com

127

Page 128: Planning aid Kitchen appliances - V-ZUG AG · Kitchen appliances 03.09.14 info@vzug.com, 9. 2 Ovens 2.1 Electrical connection data Appliance Country group * Mains connection Fuse

V-ZUG Ltd – in the centre of Europe,in the heart of Switzerland

Welcome! V-ZUG Ltd Industriestrasse 66 P.O. Box 59 6301 Zug, Switzerland Tel. +41 58 767 67 78 [email protected] www.vzug.com

The Swiss Leader