Upload
bartholomew-samson-atkins
View
227
Download
0
Tags:
Embed Size (px)
Citation preview
PipeGuard PipeGuard byby MAGAL MAGAL
The Pipelines Security Solution for BOTAThe Pipelines Security Solution for BOTASSThe Pipelines Security Solution for BOTAThe Pipelines Security Solution for BOTASS
MAGAL proprietary and commercially secret information.
Not to be copied to third parties without MAGAL’s prior written permission
PipeGuard’s BackgroundPipeGuard’s Background
• Although being recognized as a strong need by the oil & Gas industry for years - Securing the pipes has been an unanswered challenge till nowSecuring the pipes has been an unanswered challenge till now.
• Magal has identified that need, and has implemented a unique identification identification technology developed in the Technion Technion (Israel institute of technology) .(Israel institute of technology) .
• Together with unique short range communication technology - and in-house in-house command & control systemcommand & control system – the PipeGuard patent based comprehensive solution.
Regional Theatre during Digging EventRegional Theatre during Digging Event
3 –
20
Km
PipeGuard sensing
unit
PipeGuard sensing
unit
Pipeline existing regional stationPipeline existing regional station
Pipeline control center
Pipeline control center
Pipeline Patrol vehicle
Pipeline Patrol vehicle
Wireless LAN, Video, GPS, data
PipeGuard is good for: PipeGuard is good for:
The PipeGuard was find suitable to the following applications:
• Oil & Gas industry:–Theft
–Terror
–3rd party
• Underground Data transfer highways (buried fiber optics).
• Tunnels digging detection (prisons)
PipeGuard main CharacteristicsPipeGuard main Characteristics
• Non-exposed components.Non-exposed components.
• Damage preventionprevention by alarming at preparation phase .
• Inherent recognition capabilityrecognition capability – of more then 95%.
• Accurate locationlocation.
• All weather all soil typesall soil types operation.
• System redundancySystem redundancy.
• AdaptiveAdaptive to typical local signals and noise .
• Fits all pipesFits all pipes – from existing and operational to new under construction ones.
Basic logic flow of a “sensing unit”Basic logic flow of a “sensing unit”
Seismic signature bank
Seismic signature bank
Signal analysis
Signal analysis
==
ALARM message ALARM message
DiscardDiscard
NO
YES
OutputOutput
PipeGuard Uniqueness PipeGuard Uniqueness
• Combination of seismic sensors (Geo-Phones) Geo-Phones) with an advanced identification identification capability capability .
• The Discrete buried sensing units are autonomousautonomous. Signal analysis is fully conducted in every unit, thus “Alert message” is forwarded to the control room only when the signal is recognized as “real”.
• Wireless Communication is based on short range transmission to both neighboring units, and on to the nearest pumping station to avail duplex communication chain.
• The principal of continuously signal-monitoring enables adaptive performance and time enhancement..
Conceptual Comparison: Conceptual Comparison: critical parameterscritical parameters
#CharacterPipeGuardFiber-optic wireDetecting wire
1Intrusion identificationVery good (Pd>95%)Medium - LowNone
2Multiple eventVery goodLowNone
3FARVery lowMediumVery low
4Location accuracyHighHighMedium
5Damage preventiongoodMediumNone
6Robustness High. System is constructed on
independent detectors
Low. Failure of the Fiber-Optic wire will fail the
whole system
Low. Failure of the wire will fail the whole system
√X
Schematic SummarySchematic Summary
System installationSystem installation
System Installation & ComponentsSystem Installation & Components
Signal analyzer
Transceiver
50-80 cm
Ground level
“sensing unit” “sensing unit”
Power source
Principal of Phased Array CoveragePrincipal of Phased Array Coverage(Top view)(Top view)
Shape of coverage zone
Shape of coverage zone
Geo-phones array
(Example only)
Geo-phones array
(Example only)
150 meter
3 - 5 m
Shape of coverage zone
Shape of coverage zone
100 m
System Installation ConceptSystem Installation Concept
1 Km
200 - 300 meters
Ground level
Sensing units
Sensing units
Discrete Sensing units
Discrete Sensing units
Wireless Configuration Concept SchemeWireless Configuration Concept Scheme
Ground level
Wire Configuration Concept SchemeWire Configuration Concept Scheme
60 – 80 cm
Ground level
1 – 5 m
30-40 cm
Control Center Information during AlertControl Center Information during Alert
1. Alert from sensor # 347: Digging with Pd of 98%.
2. Position is 5364/7764 (UTM).
3. Time of event: 12:43.
4. Closest patrol call-sign “Charlie 21”
5. Optional courses or response (based on pre-planned checklist).