Vascu-PICC TLS Pediatric PICC Components Description Catheter Only Basic Set OTN Basic Set MST Basic Set No MST Procedure Tray Ped. Procedure Tray Vascu-PICC TLS with pre-loaded stylet Patient information booklet Needle free valve(s) Patient chart sticker Securement device 10 cc Syringe 2” x 2” Gauze Tape measure(s) Tearaway introducer Tourniquet Guidewire Safety needle Pre-filled saline syringes (3) Safety scalpel Scissors Chlorhexidine (2) Surgical tape 37” x 24” Fenestrated drape Steri-strips Adhesive dressing Needle stick pad 5 cc Lidocaine HCL 1% Filter straw Lidocaine/saline stickers Surgical gloves (3) 40” x 70” Drape Face masks (2) 36” x 24” Drape 5 cc Syringe Bouffant cap 4” x 4” Gauze XL Gown Steel forceps 19” x 12” Fenestrated drape Designed to provide exceptional treatment for your smallest patients. Vascu-PICC TLS features dual and single lumen configurations, a polyurethane body, and high flow rates in a small French size. Since smaller veins require greater precision, it makes sense to offer you more choices in PICC sizes. Part Number Lumen Size (F) Length (cm) Catheter Only Kits MD17011100 Single 1.9 50 MD17012600 Dual 2.6 50 Basic Kits (OTN) MD17011121 Single 1.9 20 MD17011101 Single 1.9 50 MD17012621 Dual 2.6 20 MD17012601 Dual 2.6 50 Basic (No Insertion Components) MD17021121 Single 1.9 20 MD17022601 Dual 2.6 50 Basic Kits (MST) MD170111224S Single 1.9 20 MD170111024S Single 1.9 50 MD170126224S Dual 2.6 20 MD170126024S Dual 2.6 50 Maximal Barrier Kits MRVSP19001 Single 1.9 20 MRVSP26001 Dual 2.6 50 Part Number Description Accessories MR17019001 Pediatric PICC Procedure w/ Maximal Barrier Easy-to-Read Depth Marks Taperless Polyurethane Material Provides strength, versatility, and high flow rates in a smaller French size Radiopaque Identifiable under X-Ray Multiple Function Luers Eliminates separate access lines Vascu-PICC TLS Pediatric Ordering Information For all ages PICCs Pro-PICC CT, Vascu-PICC and Vascu-PICC TL Catheters INDICATION FOR USE: The Peripherally Inserted Central Vein Access Catheters are designed for Long or Short - Term peripheral access to the central venous system for intravenous therapy and blood sampling, and allows for central venous pressure monitoring. This catheter may be inserted via the basilic, cephalic, or median cubital vein. PRO-PICC CT, VASCU-PICC and VASCU-PICC TL INDICATION FOR USE: The Peripherally Inserted Central Vein Access Catheters are designed for Long or Short - Term peripheral access to the central venous system for intravenous therapy and blood sampling, and allows for central venous pressure monitoring. This catheter may be inserted via the basilic, cephalic, or median cubital vein. CONTRAINDICATIONS: This catheter is not intended for any use other than that which is indicated. Do not implant catheter in thrombosed vessels. The presence of skin related problems around the insertion site (infection, phlebitis, scars, etc.) The presence of device related bacteremia or septicemia.History of mastectomy on insertion side. Previous history of venous/subclavian thrombosis or vascular surgical procedures at insertion site. Fever of unknown origin. The patient’s body size is insufficient to accommodate the size of the implanted device. The patient is known or is suspected to be allergic to materials contained in the device. Past irradiation of prospective insertion site. Local tissue factors will prevent proper device stabilization and / or access. Refer to Directions for provided with the product for complete Instructions, Warnings, Precautions, Possible Adverse Effects and Contraindications. Observe all instructions for use prior to use. Failure to do so may result in patient complications. CAUTION: Federal Law (USA) restricts this device to sale by or on the order of a physician. VASCU-PICC TLS INDICATION FOR USE: The 1.9F and 2.6F Peripherally Inserted Central Vein Access Catheters are indicated for short or long term access to the central venous system via peripheral insertion in neonates, infants, and children. It may be used for administration of fluids, medication, and nutritional therapy.Recommended insertion sites are the median cubital vein of the elbow or the basilic vein. The long saphenous veins of the ankle may also be used. This catheter is not suitable for insertion through nonsuperficial veins. CONTRAINDICATIONS: This catheter is not intended for any use other than that which is indicated. Do not implant catheter in thrombosed vessels. The presence of skin related problems around the insertion site (infection, phlebitis, scars, etc.) The presence of device related bacteremia or septicemia. Previous history of venous/subclavian thrombosis or vascular surgical procedures at insertion site. Fever of unknown origin. The patient's body size is insufficient to accommodate the size of the implanted device. The patient is known or is suspected to be allergic to materials contained in the device. Past irradiation of prospective insertion site. Local tissue factors will prevent proper device stabilization and/ or access. Refer to Directions for provided with the product for complete Instructions, Warnings, Precautions, Possible Adverse Effects and Contraindications. Observe all instructions for use prior to use. Failure to do so may result in patient complications. CAUTION: Federal Law (USA) restricts this device to sale by or on the order of a physician. Vascu-PICC TLS Catheters The 1.9F and 2.6F Peripherally Inserted Central Vein Access Catheters are indicated for short or long term access to the central venous system via peripheral insertion in neonates, infants, and children. It may be used for administration of fluids, medication, and nutritional therapy. Recommended insertion sites are the median cubital vein of the elbow or the basilic vein. The long saphenous veins of the ankle may also be used. This catheter is not suitable for insertion through nonsuperficial veins. CONTRAINDICATIONS: The Pro-PICC, Vascu-PICC, Vascu-PICC TL and Vascu- PICC TLS Catheters are not intended for any use other than that which is indicated. Do not implant catheter in thrombosed vessels. The presence of skin related problems around the insertion site (infection, phlebitis, scars, etc.) The presence of device related bacteremia or septicemia. History of mastectomy on insertion side. Previous history of venous/subclavian thrombosis or vascular surgical procedures at insertion site. Fever of unknown origin. The patient’s body size is insufficient to accommodate the size of the implanted device. The patient is known or is suspected to be allergic to materials contained in the device. Past irradiation of prospective insertion site. Local tissue factors will prevent proper device stabilization and / or access. Refer to Directions for provided with the product for complete Instructions, Warnings, Precautions, Possible Adverse Effects and Contraindications. Observe all instructions for use prior to use. Failure to do so may result in patient complications. CAUTION: Federal Law (USA) restricts this device to sale by or on the order of a physician. IMPORTANT RISK INFORMATION USA > 14 Plaza Drive, Latham, NY 12110 > tel: 800-772-6446 or 518-798-1215 > fax: 518-798-1360 International > Haaksbergweg 75 (Margriettoren), 1101 BR, Amsterdam Z-O > The Netherlands tel: +31 (0)20 753 2949 > fax: +31 (0)20 753 2939 www.angiodynamics.com Distributed by AngioDynamics, Inc. *AngioDynamics and the AngioDynamics logo are trademarks and/or registered trademarks of AngioDynamics, Inc., an affiliate or a subsidiary. Medcomp, the Medcomp logo, Vascu-PICC, the Vascu-PICC logo, VASCU-PICC TL, the VASCU-PICC TL logo, Pro-PICC, and the Pro-PICC logo, are trademarks and/or registered trademarks of Medical Components, Inc. All other trademarks are property of their respective owners. © 2020 AngioDynamics, Inc. US/VA/BR/590 Rev 02 01/2021 Consult your AngioDynamics representative for country specific product availability.

PICCs...Basic Kits (MST) MD170111224S Single 1.9 20 MD170111024S Single 1.9 50 MD170126224S Dual 2.6 20 MD170126024S Dual 2.6 50 Maximal Barrier Kits MRVSP19001 Single 1.9 …

  • Upload
    others

  • View
    1

  • Download
    0

Embed Size (px)

Citation preview

Page 1: PICCs...Basic Kits (MST) MD170111224S Single 1.9 20 MD170111024S Single 1.9 50 MD170126224S Dual 2.6 20 MD170126024S Dual 2.6 50 Maximal Barrier Kits MRVSP19001 Single 1.9 …

Vascu-PICC TLS Pediatric PICC Components

Description Catheter Only Basic Set OTN Basic Set MST Basic Set No MST Procedure Tray Ped. Procedure TrayVascu-PICC TLS with pre-loaded stylet

Patient information booklet

Needle free valve(s)

Patient chart sticker

Securement device

10 cc Syringe

2” x 2” Gauze

Tape measure(s)

Tearaway introducer

Tourniquet

Guidewire

Safety needle

Pre-filled saline syringes (3)

Safety scalpel

Scissors

Chlorhexidine (2)

Surgical tape

37” x 24” Fenestrated drape

Steri-strips

Adhesive dressing

Needle stick pad

5 cc Lidocaine HCL 1%

Filter straw

Lidocaine/saline stickers

Surgical gloves (3)

40” x 70” Drape

Face masks (2)

36” x 24” Drape

5 cc Syringe

Bouffant cap

4” x 4” Gauze

XL Gown

Steel forceps

19” x 12” Fenestrated drape

Designed to provide exceptional treatment for your smallest patients. Vascu-PICC TLS features dual and single lumen configurations, a polyurethane body, and high flow rates in a small French size. Since smaller veins require greater precision, it makes sense to offer you more choices in PICC sizes.

Part Number Lumen Size (F) Length (cm)

Catheter Only Kits

MD17011100 Single 1.9 50

MD17012600 Dual 2.6 50

Basic Kits (OTN)

MD17011121 Single 1.9 20

MD17011101 Single 1.9 50

MD17012621 Dual 2.6 20

MD17012601 Dual 2.6 50

Basic (No Insertion Components)

MD17021121 Single 1.9 20

MD17022601 Dual 2.6 50

Basic Kits (MST)

MD170111224S Single 1.9 20

MD170111024S Single 1.9 50

MD170126224S Dual 2.6 20

MD170126024S Dual 2.6 50

Maximal Barrier Kits

MRVSP19001 Single 1.9 20

MRVSP26001 Dual 2.6 50

Part Number Description

Accessories

MR17019001 Pediatric PICC Procedure w/ Maximal Barrier

Easy-to-Read Depth Marks

Taperless

Polyurethane Material Provides strength, versatility,

and high flow rates in a smaller French size

Radiopaque Identifiable under X-Ray

Multiple Function Luers Eliminates separate access lines

Vascu-PICC TLS Pediatric Ordering Information

For all ages

PICCs

Pro-PICC CT, Vascu-PICC and Vascu-PICC TL Catheters

INDICATION FOR USE: The Peripherally Inserted Central Vein Access Catheters are designed for Long or Short - Term peripheral access to the central venous system for intravenous therapy and blood sampling, and allows for central venous pressure monitoring. This catheter may be inserted via the basilic, cephalic, or median cubital vein.

PRO-PICC CT, VASCU-PICC and VASCU-PICC TL

INDICATION FOR USE: The Peripherally Inserted Central Vein Access Catheters are designed for Long or Short - Term peripheral access to the central venous system for intravenous therapy and blood sampling, and allows for central venous pressure monitoring. This catheter may be inserted via the basilic, cephalic, or median cubital vein.

CONTRAINDICATIONS: This catheter is not intended for any use other than that which is indicated. Do not implant catheter in thrombosed vessels. The presence of skin related problems around the insertion site (infection, phlebitis, scars, etc.) The presence of device related bacteremia or septicemia.History of mastectomy on insertion side. Previous history of venous/subclavian thrombosis or vascular surgical procedures at insertion site. Fever of unknown origin. The patient’s body size is insufficient to accommodate the size of the implanted device. The patient is known or is suspected to be allergic to materials contained in the device. Past irradiation of prospective insertion site. Local tissue factors will prevent proper device stabilization and / or access. Refer to Directions for provided with the product for complete Instructions, Warnings, Precautions, Possible Adverse Effects and Contraindications. Observe all instructions for use prior to use. Failure to do so may result in patient complications. CAUTION:

Federal Law (USA) restricts this device to sale by or on the order of a physician.

VASCU-PICC TLS

INDICATION FOR USE: The 1.9F and 2.6F Peripherally Inserted Central Vein Access Catheters are indicated for short or long term access to the central venous system via peripheral insertion in neonates, infants, and children. It may be used for administration of fluids, medication, and nutritional therapy.Recommended insertion sites are the median cubital vein of the elbow or the basilic vein. The long saphenous veins of the ankle may also be used. This catheter is not suitable for insertion through nonsuperficial veins.

CONTRAINDICATIONS: This catheter is not intended for any use other than that which is indicated. Do not implant catheter in thrombosed vessels. The presence of skin related problems around the insertion site (infection, phlebitis, scars, etc.) The presence of device related bacteremia or septicemia. Previous history of venous/subclavian thrombosis or vascular surgical procedures at insertion site. Fever of unknown origin. The patient's body size is insufficient to accommodate the size of the implanted device. The patient is known or is suspected to be allergic to materials contained in the device. Past irradiation of prospective insertion site. Local tissue factors will prevent proper device stabilization and/ or access. Refer to Directions for provided with the product for complete Instructions, Warnings, Precautions, Possible Adverse Effects and Contraindications. Observe all instructions for use prior to use. Failure to do so may result in patient complications. CAUTION: Federal Law (USA) restricts this device to sale by or on the order of a physician.

Vascu-PICC TLS Catheters

The 1.9F and 2.6F Peripherally Inserted Central Vein Access Catheters are indicated for short or long term access to the central venous system via peripheral insertion in neonates, infants, and children. It may be used for administration of fluids, medication, and nutritional therapy. Recommended insertion sites are the median cubital vein of the elbow or the basilic vein. The long saphenous veins of the ankle may also be used. This catheter is not suitable for insertion through nonsuperficial veins.

CONTRAINDICATIONS: The Pro-PICC, Vascu-PICC, Vascu-PICC TL and Vascu-PICC TLS Catheters are not intended for any use other than that which is indicated. Do not implant catheter in thrombosed vessels. The presence of skin related problems around the insertion site (infection, phlebitis, scars, etc.) The presence of device related bacteremia or septicemia. History of mastectomy on insertion side. Previous history of venous/subclavian thrombosis or vascular surgical procedures at insertion site. Fever of unknown origin. The patient’s body size is insufficient to accommodate the size of the implanted device. The patient is known or is suspected to be allergic to materials contained in the device. Past irradiation of prospective insertion site. Local tissue factors will prevent proper device stabilization and / or access.

Refer to Directions for provided with the product for complete Instructions, Warnings, Precautions, Possible Adverse Effects and Contraindications. Observe all instructions for use prior to use. Failure to do so may result in patient complications.

CAUTION: Federal Law (USA) restricts this device to sale by or on the order of a physician.

IMPORTANT RISK INFORMATION

USA > 14 Plaza Drive, Latham, NY 12110 > tel: 800-772-6446 or 518-798-1215 > fax: 518-798-1360International > Haaksbergweg 75 (Margriettoren), 1101 BR, Amsterdam Z-O > The Netherlandstel: +31 (0)20 753 2949 > fax: +31 (0)20 753 2939

www.angiodynamics.com

Distributed by AngioDynamics, Inc.

* AngioDynamics and the AngioDynamics logo are trademarks and/or registered trademarks of AngioDynamics, Inc., an affiliate or a subsidiary. Medcomp, the Medcomp logo, Vascu-PICC, the Vascu-PICC logo, VASCU-PICC TL, the VASCU-PICC TL logo, Pro-PICC, and the Pro-PICC logo, are trademarks and/or registered trademarks of Medical Components, Inc. All other trademarks are property of their respective owners. © 2020 AngioDynamics, Inc. US/VA/BR/590 Rev 02 01/2021

Consult your AngioDynamics representative for country specific product availability.

Page 2: PICCs...Basic Kits (MST) MD170111224S Single 1.9 20 MD170111024S Single 1.9 50 MD170126224S Dual 2.6 20 MD170126024S Dual 2.6 50 Maximal Barrier Kits MRVSP19001 Single 1.9 …

Vascu-PICC TL (Taperless) Ordering Information

Part Number Lumen Size (F) Length (cm)

Basic Kits (MST)

MD81013101 Single 3 60

MD81014101* Single 4 60

MD81014201* Dual 4 60

MD81015201* Dual 5 60

Maximal Barrier Kits

MR81013106MB Single 3 60

MR81014106MB Single 4 60

MR81014206MB Dual 4 60

MR81015206MB Dual 5 60

*AngioDynamics does not keep high inventory levels of this code.Please check with your sales representative for availability and lead times.

Bi-Directional Performance Valve

Pro-PICC CT Ordering Information

Part Number Lumen Size (F) Length (cm)

Catheter Only Kits

MD17033100 Single 3 55

Basic Kits (MST)

MD17033101 Single 3 55

MD17034101 Single 4 55

MD17035101 Single 5 60

MD17035201 Dual 5 55

MD17035211* Dual 5 55

MD17036201 Dual 6 60

MD17036301 Triple 6 60

MD17035222** Dual 5 55

MR17036322** Triple 6 60

IR/Long Wire Kits

MD17033102 Single 3 55

MD17034102 Single 4 55

MD17035102MD17035111*

Single 5 60

MD17035202MD17035211*MD17035222**

Dual 5 55

MD17036202 Dual 6 60

MD17036302MR17036322**

Triple 6 60

* Has flushable stylet ** Has 0.016" guidewire and no stylet

CT, Non-Valved Catheters

The Pro-PICC CT Catheter reduces patient trauma and risks associated with secondary venous access by allowing for the combination of CT Power Injection capabilities and infusion therapy. Flow rates are easily identifiable on the ID tags, which also provide strength and durability for repeated use.

CT, Valved Catheters

The Pro-PICC Valved Catheter can be used for power injection of contrast media and central venous pressure (CVP) monitoring. The catheter's bi-directional valve allows for ease of aspiration.

Pro-PICC, Vascu-PICC and Vascu-PICC TL PICC Kit Components

Description Catheter Only Basic Set MST IR Kit (Long Wire) Nursing Kit Full Nursing Kit Maximal Barrier Kit

PICC (w/ stylet)

Peelable sheath introducer

Mini scalpel

Guidewire

10 cc Syringe

Tape measure(s)

Introducer needle

Needle free valve(s)

Catheter securement device

Patient information pack

Patient chart sticker*

Patient ID card*

Safety scalpel

Safety introducer needle

Safety Needle

Tourniquet

5 cc Syringe

Surgical Tape

Pre-filled saline syringe(s)

Chlorhexidine

Tinted chlorhexidine

5 cc Lidocaine

Adhesive wound dressing

Needle stick pad

4” x 4” Gauze

Surgical gloves

Filter straw

Scissors

Steri-strips

Face mask(s)

2” x 2” Gauze

Fenestrated drape

Drape

Safety hypodermic needle

Lidocaine/saline stickers

Full body drape

XL gown

Surgical face mask with eye shield

Bouffant cap

Probe cover with gel

*Patient ID cards are not included in VASCU-PICC Kits

Part Number Lumen Size (F) Length (cm)

Basic Nursing Kits

MD17033105 Single 3 55

MD17034105 Single 4 55

MD17035105 Single 5 60

MD17035205 Dual 5 55

MD17036205 Dual 6 60

MD17036305 Triple 6 60

Full Nursing Kits

MR17033106 Single 3 55

MR17034106 Single 4 55

MR17035206 Dual 5 55

MR17036306 Triple 6 60

Maximal Barrier Kits

MR17033106MB Single 3 55

MR17034106MB Single 4 55

MR17035106MB Single 5 60

MR17035206MB Dual 5 55

MR17036306MB Triple 6 60

Pro-PICC Ordering Information

Part Number Lumen Size (F) Length (cm)

Basic Kits (MST)

MD82034101* Single 4 55

MD82035101* Single 5 60

MD82035201* Double 5 55

MD82036301* Triple 6 60

*AngioDynamics does not keep high inventory levels of this code.Please check with your sales representative for availability and lead times.† CAN approved only

Part Number Description

Accessories

MR17019000 PICC Procedure Tray w/ Maximal Barrier

MR17019001 Pediatric PICC Procedure Tray w/ Maximal Barrier

MR190000 Maximal Barrier Protection Tray

MR190001 Accessory Pack (Gown, Drape, Cap, Mask)

Printed Identification and Purple Color

denote maximum flow rates for contrast injection

Easy-to-Read Depth Marks for easy identification

of catheter length

Size (F) Lumen Flow Rate

4 Single 5 cc/sec

5 Single 5 cc/sec

5 Dual 5 cc/sec

6 Dual 5 cc/sec

6 Triple 5 cc/sec

Non-CT, Non-Valved Catheters

Vascu-PICC and Vascu-PICC TL catheters provide a range of options to meet the unique needs of your patients. Vascu-PICC offers a tapered design that may help reduce bleeding at the insertion site, while Vascu-PICC TL features a taperless lumen, ideal for smaller vasculature.

Vascu-PICC Ordering Information

Part Number Lumen Size (F) Length (cm)

Catheter Only Kits

MD17013100 Single 3 60

Basic Kits (MST)

MD17013101 Single 3 60

MD17014101 Single 4 60

MD17015101 Single 5 60

MD17014201 Dual 4 60

MD17015201 Dual 5 60

MD17016201* Dual 6 60

*AngioDynamics does not keep high inventory levels of this code.Please check with your sales representative for availability and lead times.

Part Number Lumen Size (F) Length (cm)

IR/Long Wire Kits

MD17015202 Dual 5 60

Basic Nursing Kits

MD17013105 Single 3 60

MD17014105 Single 4 60

MD17014205 Dual 4 60

Maximal Barrier Kits

MR17014106MB Single 4 60

MR17015206MB Dual 5 60

Easy-to-Read Depth Marks

Taperless (Vascu-PICC TL) or Tapered (Vascu-PICC) Design

Polyurethane Material

Radiopaque Identifiable under X-Ray