4
www.UsePhoenix.com DESIGN PERFORMANCE innovative proven V ALUE exceptional Made in USA FireBird HD308 System – 4032510 (with generator), 4032500 (without generator) Phoenix FireBird HD308 Hydronic Diesel Heat Drying System Designed and built for the rigors of the restoration industry, the Phoenix FireBird HD308 is the safest, most efficient, flexible, and durable heat system made. The FireBird HD308 uses superior design to maximize heating capacity and minimize your fuel cost, while its innovative safety features and system flexibility create revenue opportunities unavailable to competing units. System includes: 4 - TX 80 Fan Coils 1 - HD308 Heating Unit 1 - 7’ x 14’ Enclosed Trailer 2 - 1” x 50’ Hoses 8 - 3/4” x 50’ Hoses 2 - Manifolds 2 - Filter Boxes (11kW Generator - included with 4032510 System) System Warranty: One Full Year – Parts and Labor (Generator not included in Phoenix Warranty) Capacity – Through superior design, the HD308 can heat larger areas than competing units. The Phoenix key advantage is in its system setup. By recirculating at least two-thirds of the airflow and associated BTUs, and using up to one-third outside air, the HD308 heats structures very quickly and evenly, while using far less fuel than competing units. The result of this quick and even heat distribution is that even large structures are brought up to temperature quickly, maximizing the speed of evaporation while minimizing the possibility of secondary damage often associated with cold spots and pressurization. Efficiency The FireBird HD308 features the highest system efficiency in the market, providing the most heating capacity per gallon of fuel consumed. Even at maximum output, the FireBird HD308 burns only 2.4 gallons of fuel per hour. Once the structure is up to temperature, fuel consumption drops to less than 1 gallon per hour. Flexibility Multiple fan coils allow numerous heating configurations and the flexibility to scale your equipment to the job size. In addition, Phoenix glycol lines can be run up to 300 feet vs. flex duct, which can only extend 25 to 50 feet, giving you access to many jobs that are physically unreachable with competing systems and ensuring effective and even heat distribution throughout the structure. Finally, unlike the propane-fired burners, which have transportation problems, fuel availability issues, and altitude limitations, the FireBird HD308, with its efficient diesel burner and 120 gallon onboard tank, can be transported virtually anywhere and has enough onboard fuel to finish the majority of heat drying jobs. Safety The FireBird HD308 is UL, CSA, and TUV certified for safe operation. Unlike direct-fired competitors, the HD308 completely isolates combustion gases from the heat source, rather than blowing them into the structure, while using a low pressure, open glycol system specifically designed for the restoration professional. Return on Investment Capacity, efficiency, flexibility, and safety add up to a better return on your investment. The FireBird HD308 can heat more with less fuel, in more situations, maximizing the number of restoration jobs you can do and the profitability on each job. The FireBird HD308 System also offers a variety of additional revenue opportunities; including emergency temporary heat after weather events, fires, and power outages; construction site heat applications and outdoor events, such as weddings. These applications can boost your equipment use and expand your revenue. Just Pull Up to the Jobsite and Start Drying with Phoenix. The Phoenix FireBird HD308 is the industry leader in:

Phoenix FireBird HD308 · Phoenix FireBird HD308 is the safest, most efficient, flexible, and durable heat system made. The FireBird HD308 uses superior design to maximize heating

  • Upload
    vothuan

  • View
    220

  • Download
    0

Embed Size (px)

Citation preview

www.UsePhoenix.com DESIGN PERFORMANCEinnovative proven™

VALUE exceptionalMade in USA

FireBird HD308 System – 4032510 (with generator), 4032500 (without generator)

Phoenix FireBird HD308Hydronic Diesel Heat Drying System

Designed and built for the rigors of the restoration industry, the Phoenix FireBird HD308 is the safest, most efficient, flexible, and durable heat system made. The FireBird HD308 uses superior design to maximize heating capacity and minimize your fuel cost, while its innovative safety features and system flexibility create revenue opportunities unavailable to competing units.

System includes:

4 - TX 80 Fan Coils 1 - HD308 Heating Unit 1 - 7’ x 14’ Enclosed Trailer 2 - 1” x 50’ Hoses 8 - 3/4” x 50’ Hoses 2 - Manifolds 2 - Filter Boxes (11kW Generator - included with 4032510 System)

System Warranty: One Full Year – Parts and Labor (Generator not included in Phoenix Warranty)

Capacity – Through superior design, the HD308 can heat larger areas than competing units. The Phoenix key advantage is in its system setup. By recirculating at least two-thirds of the airflow and associated BTUs, and using up to one-third outside air, the HD308 heats structures very quickly and evenly, while using far less fuel than competing units. The result of this quick and even heat distribution is that even large structures are brought up to temperature quickly, maximizing the speed of evaporation while minimizing the possibility of secondary damage often associated with cold spots and pressurization.

Efficiency – The FireBird HD308 features the highest system efficiency in the market, providing the most heating capacity per gallon of fuel consumed. Even at maximum output, the FireBird HD308 burns only 2.4 gallons of fuel per hour. Once the structure is up to temperature, fuel consumption drops to less than 1 gallon per hour.

Flexibility – Multiple fan coils allow numerous heating configurations and the flexibility to scale your equipment to the job size. In addition, Phoenix glycol lines can be run up to 300 feet vs. flex duct, which can only extend 25 to 50 feet, giving you access to many jobs that are physically unreachable with competing systems and ensuring effective and even

heat distribution throughout the structure. Finally, unlike the propane-fired burners, which have transportation problems, fuel availability issues, and altitude limitations, the FireBird HD308, with its efficient diesel burner and 120 gallon onboard tank, can be transported virtually anywhere and has enough onboard fuel to finish the majority of heat drying jobs.

Safety – The FireBird HD308 is UL, CSA, and TUV certified for safe operation. Unlike direct-fired competitors, the HD308 completely isolates combustion gases from the heat source, rather than blowing them into the structure, while using a low pressure, open glycol system specifically designed for the restoration professional.

Return on Investment – Capacity, efficiency, flexibility, and safety add up to a better return on your investment. The FireBird HD308 can heat more with less fuel, in more situations, maximizing the number of restoration jobs you can do and the profitability on each job. The FireBird HD308 System also offers a variety of additional revenue opportunities; including emergency temporary heat after weather events, fires, and power outages; construction site heat applications and outdoor events, such as weddings. These applications can boost your equipment use and expand your revenue.

Just Pull Up to the Jobsite and Start Drying with Phoenix.

The Phoenix FireBird HD308 is the industry leader in:

www.UsePhoenix.com [email protected]

4201 Lien Rd. 608-237-8400

Madison, WI 53704 1-800-533-7533

Therma-Stor LLC 02/13

Specifications subject to change without notice.

Hydronic Diesel Heat Drying System

Phoenix FireBird HD308 Hydronic Heating Unit

Designed and built from the ground up for the rigors of the restoration industry, the Phoenix FireBird HD308 offers unparalleled performance, efficiency, and durability. Offering 308,000 BTUs of heating capacity, the Phoenix FireBird HD308 provides a central source of hot heat transfer fluid (HTF) for a variety of restoration application including emergency temporary heat after weather events, fires, and power outages; construction site heat applications and outdoor events, such as weddings. These applications can boost your equipment use and expand your revenue.

The FireBird HD308 is diesel-fuel fired. The first step in landing a big restoration job is getting there. Most competing systems burn propane, which is becoming more and more difficult to transport. Many large cities, such as New York, Boston, and Washington D.C., do not allow liquid propane to be transported unless specifically licensed and authorized to do so. Similarly, propane can no longer be legally transported through tunnels or over many bridges. In large, widespread storm zones, finding propane or obtaining refills for your equipment can be impossible. As a result, the number of restoration jobs that can be done with propane fired heat systems is declining quickly. With its diesel burner and 120 gallon onboard tank, the FireBird

HD308 can be transported virtually anywhere and has enough onboard fuel to finish almost any drying job. Even if refueling is necessary, the restorer can use a portable tank and transport pump to refuel rather than relying on an expensive fueling service.

Assuming you can get to your job and have access to enough fuel to heat it, you need the flexibility to adapt to as many job sizes and setups as possible. Glycol lines can be run much farther than flex duct (up to 300 feet vs. 25 to 50 feet), giving you access to many jobs that are physically unreachable with competing systems. Multiple fan coils allow you to not only scale your equipment to the job size, but also help you ensure that heat is dispersed evenly and effectively throughout the structure. This is particularly important in areas that have multiple rooms, where a central fan leaves wet spots in any area outside the airflow path.

Like all Phoenix equipment, safety was a primary concern in the design and manufacturing of the HD308. Unlike direct-fired competitors, the HD308 completely isolates flue by-products from the heat source, rather than blowing them into the structure. As a result, combustion by-products such as carbon dioxide and carbon monoxide are safely vented out a chimney 50 feet (or more) from the structure instead of blown into your customers’ structures or homes.

The Phoenix FireBird HD308 is built to last. All exposed components are made of non-corrosive stainless steel and aluminum. For easy diagnostics, all FireBird HD308 gauges and indicators are clearly visible even when the unit is securely locked down. In addition to the standard temperature, pressure, fuel level, and HTF level gauges, the FireBird HD308 control system includes a sequence of status indicator lights which provide a quick function check and easy troubleshooting.

Features:• 308,000 BTU Capacity

• Atmospherically-Vented HTF Circuit

• Stainless Steel and Aluminum Construction

HD308 Heating Unit SpecificationsPart No. 4031010Fuel Input 308,000 BTU/hrFuel Options Diesel Run Time at Full Load 50 HoursEfficiency 85%Heat Transfer Fluid Propylene Glycol Pump 1 HPLifting Hook 1 Operating Temp Range -30°F to 140°FFluid Temperature 100°F to 200°F RangeFuel Tank Capacity 120 GallonsFuel Consumption at Full Load 2.4 GallonsHydronic Flow Rate 30 GPM, 1.89 liters/secHydronic Connections 1” ISO 7241 Series B CouplingsDimensions 72”L x 31”W x 48”H - inches 1829L x 787W x 1219H - millimeters (Cabinet with Fuel Tank) Weight 800 lbs. / 363 kg (Empty Fuel Tank) 1700 lbs. / 771 kg (Full Fuel Tank)HD308 Hydronic Heating Unit Xactimate Code: Heat>

www.UsePhoenix.com [email protected]

4201 Lien Rd. 608-237-8400

Madison, WI 53704 1-800-533-7533

Therma-Stor LLC 02/13

Specifications subject to change without notice.

Kubota GL11000 11kW Generator Kubota Specifications

Output 11kW - Standby 10kW - PrimePower 120/240V 83.4 Amps, 120 Vac 41.7 Amps, 240 Vac Single PhaseFrequency 60HzFuel Diesel fuel No. 2 (ASTM D975) Engine Type Vertical, Liquid-cooled, 4-cycle diesel engineSound Level 68dB (A)Dimensions 50.4”W x 24.3”H X 27.5”D

Weight 650 lbs.

Generator is optional.(Included with 4032510 System)

Features• Thermostatically Controlled

• Multiple Ducting Options

• Multiple Filtration Options

• Stainless Steel Construction

• Inboard wheels

• Integrated Lift hook

• ETL/CSA Certified

System includes: 4 TX 80 Fan Coils

Phoenix FireBird TX 80 Fan Coil FireBird TX 80 SpecificationsPart No. 4029790Output 80,000 BTU/hrBlower 950 CFMPower 1.8 full load amps, 120 Vac, GroundedOperating -30°F to 140°F Temp RangeThermostat 30°F to 120°F RangeFilter Box Filter Size: 16” x 16” x 2”(optional)Ducting Inlet: 16” Flex Duct (optional) Connections Supply: 14” Lay-Flat DuctHydronic 3/4” ISO 7241 Series B couplings Connections

Dimensions 20.25”W x 40”H X 21.375”D

Weight 85 lbs.

Trailer Specifications

GVWR 7,000 lbs.Dimensions 7’ x 14’, enclosedAxle TandemBrakes ElectricLights 6 pole connector

Hook-up 2” Class IV ball

Features• Enclosed design provides

secure storage and weather protection

• 7,000 lbs. GVWR leaves plenty of capacity to store additional equipment

7’ x 14’ Enclosed Trailer

Glycol Distribution SystemFeatures• High quality, industrial grade

hoses and fittings for dura-bility and puncture resistance

• Precision couplings for leak-free operation

System includes: 2 - 1” x 50’ hoses 8 - 3/4” x 50’ hoses 2 manifolds

System Accessories SpecificationsHose EPDM Glycol-Compatible hose Heater to Manifold: 1” x 50’ 4030154 Manifold to Fan Coil: 3/4” x 50’ 4030153

Manifold Kit (2 ea.) 4030700

Hydronic Heater to Manifold: Connections 1” ISO 7241 Series B Couplings Manifold to Fan Coil: 3/4” ISO 7421 Series B Couplings

TX80 Xactimate Code: HeatX>

www.UsePhoenix.com [email protected]

4201 Lien Rd. 608-237-8400

Madison, WI 53704 1-800-533-7533

Therma-Stor LLC 02/13

Specifications subject to change without notice.

DESIGN VALUE PERFORMANCEinnovative exceptional proven™

MADE IN AMERICA... It’s a Phoenix

Hydronics Comparison Chart