of 8/8
For those who get there first Philips HeartStart FRx Defibrillator

Philips HeartStart FRx Defibrillator Brochure

  • View
    261

  • Download
    5

Embed Size (px)

DESCRIPTION

Philips HeartStart FRx Defibrillator Brochure

Text of Philips HeartStart FRx Defibrillator Brochure

  • For those who get there firstPhilipsHeartStartFRxDefibrillator

    452296261601.indd 1 19-8-2010 10:05:40

    The print quality of this copy is not an accurate representation of the original.

  • Philips HeartStart FRx Defibrillator2

    Anyone, anywhere, anytime

    Thecurrentsurvivalrateforsuddencardiacarrest(SCA)isunder7%

    Thelikelihoodofsuccessfulresuscitationdecreasesbyabout10%witheveryminutethatpasses

    Itisestimatedanadditional40,000livescouldbesavedeachyearintheU.S.alonewithwidespreadaccesstoAEDs1

    452296261601.indd 2 19-8-2010 10:05:49

    The print quality of this copy is not an accurate representation of the original.

  • Philips HeartStart FRx Defibrillator 3

    Anyone, anywhere, anytime

    Power to save a lifeEachyearsuddencardiacarrest(SCA)strikesnearly300,000peopleintheUS,700,000peopleinEurope,andhundredsofthousandsmoreworldwide.MorepeoplediefromSCAthanfrombreastcancer,prostatecancer,housefires,handguns,trafficaccidents,andAIDScombined.

    SCAcanhappentoanyone,anytime,anywhereandsometimesinextremeconditions.RelyonthePhilipsHeartStartFRxDefibrillatortobeuptothetask.Inthehandsofthosewhogettherefirst,itprovidesthepowertohelpsavealife.

    Coming to the rescueIn many emergency situations, police are often the

    first to arrive on the scene, and early defibrillation

    by these first responders has been shown to

    improve survival.2,3

    Taking care of businessThirteen percent of workplace fatalities reported

    in 1999 and 2000 were due to cardiac arrest.4

    Protecting kids, parents and teachersAn estimated 5,000-7,000 children in the U.S.

    succumb to sudden cardiac arrest annually,5 many

    related to sporting events.

    452296261601.indd 3 19-8-2010 10:06:09

    The print quality of this copy is not an accurate representation of the original.

  • Philips HeartStart FRx Defibrillator4

    Rugged and reliable

    ThePhilipsFRxDefibrillatorfeaturestechnologicaladvancementstohelpintreatingthemostcommoncauseofSCA.Itsdesignedtobeeasytosetupanduse,aswellasruggedandreliableforthosewhogettherefirst.Onthescenewithlawenforcement,onthefieldwithstudentathletesoronthejobwithemployees,theFRxDefibrillatoristhesolutionfortreatingSCAinenvironmentsandconditionstoodemandingforotherdefibrillators.

    Prescriptionrequired.

    452296261601.indd 4 19-8-2010 10:06:16

    The print quality of this copy is not an accurate representation of the original.

  • Philips HeartStart FRx Defibrillator 5

    Preconnected SMART Pads II SMARTPadsIIcanbeusedforbothadultsandchildren.Theyeliminatetheexpenseofhavingtopurchasedifferentsetsofpadsfordifferentpatienttypes.SMARTPadsIIenabletheFRxtokeeppacewithrespondersbyadjustingtotheiractions.

    Infant/Child keySimplyinserttheInfant/ChildkeyintotheFRxtosignaltothedevicethatyouretreatinganinfantorachild.ThedefibrillatoradjuststoprovidespecialpadsplacementandCPRinstructions.Thepadsiconsalsoflashtoshowyoutheoptimizedpadsplacement,andthedevicereducestheshockenergytoalevelmoreappropriateforaninfantorachild.

    IntuitiveCleandesignandclearvoiceinstructions,includingCPRcoaching,aredesignedtohelpinstilltheconfidencethatsneededwhentreatingapersonincardiacarrest.

    Wireless Data TransferInfrareddataportforeasytransmissiontoaSmartphoneorPCrunningEventReviewsoftware,withoutcablesorhardwirecompatibilityissues.

    Bringinginnovationtothetreatmentofcardiacarrest

    Proven therapyAtthecoreofallHeartStartDefibrillatorsisSMARTBiphasictechnology.ThePhilipsSMARTBiphasicwaveformishighlyeffective,yetminimizesharmfulsideeffects.Itseffectivenessisbackedbyover40published,peer-reviewedstudies.6

    SMARTAnalysisautomaticallyassessesthevictimsheartrhythmandisdesignednottodelivertherapyunlesstherhythmisdeterminedtobeshockableeveniftheShockbuttonispressed.AndwithpatentedQuickShock,theFRxisamongthefastestinclassatdeliveringashockafterCPR.Studiesshowthatminimizingtimeto

    shockafterCPRmayimprovesurvival.7,8,9,10,11AsAmericanHeartAssociationGuidelines2005note,Reductionintheintervalfromcompressiontoshockdeliverybyevenafewsecondscanincreasetheprobabilityofshocksuccess.12

    Designed for real world useThePhilipsHeartStartFRxDefibrillatorisexceptionallyrugged.Designedtosurpassrigoroustestingrequirements,theFRxwithstandsjettingwater,loadsupto500pounds,andaone-meterdropontoconcrete.

    452296261601.indd 5 19-8-2010 10:06:25

    The print quality of this copy is not an accurate representation of the original.

  • Philips HeartStart FRx Defibrillator6

    Built on a platform of proven ease-of-useTheHeartStartFRxDefibrillatorwasdesignedtobeaseasytouseastheHeartStartOnSiteDefibrillatorandsharesmanyofitsfeatures,includingCPRcoachingandintuitiveicon-drivenoperation.Smallandlightweightjust3.5lbs/1.5kgtheFRxisequippedtodirectyouthroughtheresuscitationofaSCAvictim.

    TheHeartStartFRxguidesyouthrougheverystepwithclear,calmvoicecommandsanddescriptivevisualicons.TheFRxevenremindsyoutocallemergencymedicalservices(EMS).Pressingthebluei-buttonactivatesHeartStartCPRCoachingforassistancewithCPR.Theflashingiconsandthequickreferenceguidecanbeusedtoleadyouthroughthedefibrillationstepseveninsituationswherehearingvoiceinstructionsisachallenge.

    OnceEMSarrives,hand-offisfastandeasybecausetheFRxiscompatiblewithadvanceddefibrillatorsliketheHeartStartMRx.WithHeartStartadapters,ourpadscanbepluggedintodevicesfromothermanufacturerstoensurecontinuityofcare.

    Easy to set upTheHeartStartFRxReady-Packconfigurationarrivestoyoucompleteandvirtuallyreadytorescue.JustpullthegreentabtoinitiatetheFRxself-test,confirmingitsreadinessforuse,andputthedevicerightintoservice.TheFRxReady-PackcomeswiththeFRxalreadyinsideitscarrycase,padspre-connected,batteryinserted,andasetofsparepadsinplace.Set-upiseasy,andyouhavethepeaceofmindofknowingthedeviceisdeployedcorrectly.

    Establishing a successful program from the startAstheworldleaderinautomatedexternaldefibrillators(AEDs),werealsoaleaderinprovidingproductsandservicesdesignedtohelpyouestablishandmaintainasuccessfulAEDprogram,includingSMARTTrackAEDprogrammanagement,medicaldirection,accesstotrainingproviders,andpost-eventsupportoptions.

    OurcustomersagreethatwithPhilips,yourewellprepared,evenacrossmultiplesiteswithhundredsorthousandsofemployees.PhilipsexpertshavehelpeddefineindustrybestpracticesinAEDprogrammanagement,andwesupportAmericanHeartAssociationandEuropeanResuscitationCouncilguidelinesforearlydefibrillationprograms.

    Designed to be the easiest-to-own AED

    Easy as 1 2 3 in an emergency

    1Press the green On/Off button, which activates voice instruction

    and visual icons.

    2Place the pads on the patient as directed.

    3When advised by the device, press the orange Shock button.

    Reliability backed by PhilipsEveryHeartStartFRxgoesthrougha120-pointqualitytestbeforeitleavesthefactory.TheHeartStartFRxDefibrillatorispoweredbyaneasy-to-install,long-life(four-year)battery,soyouknowthedeviceischargedandready.Thedevicesautomateddaily,weekly,andmonthlyself-testscheckpadreadiness,andverifyfunctionalityandcalibrationofcircuitsandsystems.Withover85tests,theFRxisoneofthemostcomprehensiveself-testingdevicesonthemarketandisvirtuallymaintenance-free.TheblinkinggreenReadylightonthedefibrillatorisyourassurancethatthedevicehaspasseditslastselftestandthereforeisreadyforuse.

    452296261601.indd 6 19-8-2010 10:06:29

    The print quality of this copy is not an accurate representation of the original.

  • Philips HeartStart FRx Defibrillator 7

    HeartStart FRx Defibrillator specificationsDefibrillatorDefibrillatorfamily

    Order861304.Defibrillator,battery,SMARTPadsII(1set),SetupandMaintenanceGuides,OwnersManual,QuickReferenceGuide,Datesticker

    HeartStartFRxReady-Packconfiguration

    OrderOptionR01.Defibrillator,battery,carrycase,SMARTPadsII(1pre-connectedset,1spareset),SetupandMaintenanceGuides,OwnersManual,QuickReferenceGuide,DateSticker

    Waveform TruncatedExponentialBiphasic.Waveformparametersadjustedasafunctionofeachpatientsimpedance

    Therapy Adultdefibrillation:Peakcurrent32A(150Jnominalintoa50-ohmload).PediatricdefibrillationwithoptionalFRxInfant/Childkeyinstalled:Peakcurrent19A(50Jnominalinto50-ohmload)

    Protocol Devicefollowspreconfiguredsettings.DefibrillationandCPRprotocolcanbecustomizedusingHeartStartEventReviewsoftware

    User interfaceInstructions Detailedvoicepromptsandvisualiconsguide

    responderthroughuseofthedefibrillatorCPRcoaching Voicecoachingforadultandinfant/childCPR

    providesinstructionsandaudiocuesfortheappropriatenumber,rateanddepthofchestcompressions,aswellasforeachbreath

    Controls GreenOn/Offbutton,bluei-button,orangeShockbutton,optionalInfant/Childkey

    Indicators Readylight,bluei-button,cautionlight,illuminatedpads,icons,Shockbuttonlightsupwhenshockisadvised

    PhysicalSize 2.4x7.1x8.9(6cmx18cmx22cm)

    DxHxWWeight Withbatteryandpadscase:3.5lbs.(1.5kg)Environmental/physical requirementsSealing WaterjetproofIPX5perIEC60529

    DustprotectedIP5XperIEC60529Temperature Operating/Standby:32-122F(0-50C)Altitude 0to15,000feetAircraft Device:RTCA/DO-160D;1997Crush 500poundsVibration Operating:meetsMILSTD810FFig.514.5C-17,

    random;Standby:meetsMILSTD810FFig.514.5C-18,sweptsine

    EMI(radiated/immunity)

    CISPRIIGroupIClassB,IEC61000-4-3,andIEC61000-4-8

    Data recording and transmissionInfrared Wirelesstransmissionofeventdatatoa

    SmartphoneorPC,usingtheIrDAprotocolHeartStartEventReviewsoftware

    Datamanagementsoftware(optional)fordownloadandreviewofdataretrievedthroughdefibrillatorsinfrareddataport

    Datastored First15minutesofECGandtheentireincidentseventsandanalysisdecisions

    Patient analysis systemPatientanalysis EvaluatespatientECGtodetermineifarhythm

    isshockable.Rhythmsconsideredshockableareventricularfibrillation(VF)andcertainventriculartachycardias(VT)associatedwithlackofcirculation.Forsafetyreasons,someVTrhythmsassociatedwithcirculationwillnotbeinterpretedasshockable,andsomeverylow-amplitudeorlow-frequencyrhythmswillnotbeinterpretedasshockableVF

    Sensitivity/specificity

    MeetsAAMIDF80guidelinesandAHArecommendationsforadultdefibrillation

    Shockadvised Abletodeliverashockassoonasthedeviceindicatesashockisadvised

    QuickShock AbletodeliverashockaftertheendofaCPRinterval,typicallyin8seconds

    Shock-to-Shockcycletime

    Typicallylessthan20secondsbetweenshocksinaseries

    Artifactdetection

    AllowsaccurateECGanalysiseveninthepresenceofmostpacemakerartifactandelectricalnoisesources.Otherartifactsaredetectedandcorrectivevoicepromptsissued

    Battery (M5070A)Itemnumber(s) Standard:M5070A

    Aviation:989803139301(TSOC-142-U.S.only)Type 9VoltDC,4.2Ah,lithiummanganesedioxide,

    disposablelong-lifeprimarycellCapacity Minimum200shocksor4hoursofoperating

    time(EN60601-2-4:2003)Install-bydate Batteryislabeledwithaninstall-bydateofat

    least5yearsfromdateofmanufactureStandbylife Fouryearstypicalwhenbatteryisinstalledbythe

    install-bydate.(WillpowertheAEDinstandbystatewithinthespecifiedstandbytemperaturerange,assuming1batteryinsertiontestandnodefibrillationuses)

    SMART Pads IIItemnumber 989803139261Activesurfacearea

    12.42(80cm2)each13.22(85cm2)each

    Cablelength 48(121.9cm)Use-bydate Padscaseislabeledwithause-bydateofatleast

    2yearsfromdateofmanufactureInfant/ChildKey Item#989803139311Training Pads IIItemnumber 989803139271Function SpecialpadsplaceHeartStartFRxintotraining

    modeanddisableitsenergydeliverycapability.Featureseightreal-worldtrainingscenarios

    Automated and user-activated self-testsDailyautomaticself-tests

    Testsinternalcircuitry,waveformdeliverysystem,pads,andbatterycapacity

    Padsintegritytest

    Specificallytestsreadiness-for-useofpads(gelmoisture)

    Batteryinsertiontest

    Uponbatteryinsertion,extensiveautomaticself-testsanduser-interactivetestcheckdevicereadiness

    Statusindicators

    BlinkinggreenReadylightindicatesreadyforuse.Audiblechirpindicatesneedformaintenance

    *RefertotheHeartStartFRxDefibrillatorOwnersManualfordetailedproductinstructions.

    Allspecificationsbasedon25Cunlessotherwisenoted.Thedefibrillatoranditsaccessoriesaremadeoflatex-freematerials.

    452296261601.indd 7 19-8-2010 10:06:29

    The print quality of this copy is not an accurate representation of the original.

  • 2010KoninklijkePhilipsElectronicsN.V.Allrightsarereserved.

    PhilipsHealthcarereservestherighttomakechangesinspecificationsand/ortodiscontinueanyproductatanytimewithoutnoticeorobligationandwillnotbeliableforanyconsequencesresultingfromtheuseofthispublication.

    PrintedinTheNetherlands.452296261601*JUL2010

    Please visit www.philips.com/FRx for more information

    1. AboutSuddenDeathandCardiacArrest.AmericanHeartAssociation.Availableat:http://www.americanheart.org/presenter.jhtml?identifier=604.AccessedJuly28,2010.

    2. WhiteRD,AsplinBR,BugliosiTF,HankinsDG.Highdischargesurvivalrateafterout-of-hospitalventricularfibrillationwithrapiddefibrillationbypoliceandparamedics.Ann Emerg Med.1996;28:480-5.

    3. MosessoVNJr,DavisEA,AubleTE,ParisPM,YealyDM.Useofautomatedexternaldefibrillatorsbypoliceofficersfortreatmentofout-of-hospitalcardiacarrest.Ann Emerg Med.1998;32:200-7.

    4. OccupationalSafety&HealthAdministration(OSHA).www.osha.gov/dts/tib/tib_data/tib20011217.pdf.

    5. BergerS,DhakaA,FriedbergDZ.SuddenCardiacDeathinInfants,ChildrenandAdolescents.Pediatric Clinics of North America.Apr.1999;46(2):221.

    6. PhilipsMedicalSystems.SMARTBiphasicStudies,listedalphabeticallybystudyauthor:http://www.healthcare.philips.com/au_en/products/resuscitation/biphasic_technology/references.wpd

    7. Yuetal.AdverseOutcomesofInterruptedPrecordialCompressionDuringAutomatedDefibrillation.Circulation.2002;106:368-372.

    8. EftesolT,SundeK,SteenPA.EffectsofInterruptingPrecordialCompressionsintheCalculatedProbabilityofDefibrillationSuccessDuringOut-of-HospitalCardiacArrest.Circulation.2002;105:2270-2273.

    9. Snyderetal.BiphasicDefibrillationWaveformCombinedwithAED-ImposedHands-OffIntervalsSignificantlyAffectOutcomeFollowingProlongedCardiacArrest.Abstractfrom7thScientificCongressoftheEuropeanCouncil.2004.

    10.Snyder&Morgan.CPRInterruptionIntervalVariesWidelyAmongCommerciallyAvailableAEDs.Abstractfrom7thScientificCongressoftheEuropeanCouncil,2004.

    11.Snyder,D.E.andMorgan,C.WideVariationsinCardiopulmonaryResuscitationIntervalsAmongCommerciallyAvailableAutomatedExternalDefibrillatorsMayAffectSurvivalDespiteHighDefibrillationEfficacy.Critical Care Medicine.2004;32(9)Supplement:S421-S424.

    12.AmericanHeartAssociation.2005AmericanHeartAssociationGuidelinesforCardiopulmonaryResuscitationandEmergencyCardiovascularCare.Circulation.2005.112:IV-36.

    PhilipsisaGlobal500companyandoneoftheworldslargestmedicalproductscompanies.

    Philipshasshippednearlythree-quartersofamillionAEDunits.

    PhilipsHeartStartdefibrillatorsaredeployedonairlinesandinairports,workplaces,schools,healthcarefacilities,andcommunitiesworldwide.

    Philips Healthcare is part of Royal Philips Electronics

    Howtoreachuswww.philips.com/[email protected]

    Asia+4970314632254

    Europe,MiddleEast,Africa+4970314632254

    LatinAmerica+551121250744

    NorthAmerica+142548770008002855585(tollfree,USonly)

    HeartStartDefibrillators+197865933328002633342(tollfree,USonly)

    452296261601.indd 8 19-8-2010 10:06:29