Document Number: 461365
AGENDA Advisory Committee on Development Design
March 21, 2018 12:00 p.m.
2nd Floor Conference Room, City Hall
A. COMMENCEMENT
B. ADOPTION OF AGENDA
C. C.1
ADOPTION OF MINUTES Committee Minutes from the meeting held February 28, 2018
D. D.1
NEW BUSINESS DP100624 Location:1616 8th Avenue New Build Applicant: Bruce Johnston Presenter: Bruce Johnston
E. ADJOURNMENT
Please confirm your attendance by contacting Leslie Jackson at [email protected]
Thank you.
Document Number: 459443
ADVISORY COMMITTEE ON DEVELOPMENT DESIGN Minutes of the City of Prince George Advisory Committee on Development Design meeting, held in the, 2nd Floor Conference Room, City Hall, 1100 Patricia Boulevard, Prince George, BC, on February 28, 2018 at 12:00 p.m.
PRESENT:
Ms. Linda Parker <Chair>; Mr. Willy Baldwin; Ms. Kathleen Petrovic (Alternate for Ms. Ashley Elliott); Mr. Vincent Hosein; Mr. Bruce Johnston; Ms. Nancy Harris; Ms. Ginny Parsons; and Mr. Lars Lindstrom. IN ATTENDANCE: Ms. Nicole Fraser, Planner; and Ms. Leslie Jackson, Legislative Coordinator.
A. Commencement
The meeting was called to order at 12:00 p.m.
B. Adoption of Agenda
Moved by Mr. Baldwin, seconded by Ms. Parsons, that the agenda for the February 28, 2018 Advisory Committee on Development Design, BE ADOPTED.
Carried Unanimously
C.
C.1
Adoption of Minutes
Committee Minutes from the meeting held February 7, 2018 Moved by Ms. Parker, seconded by Ms. Harris, that the Advisory Committee on Development Design minutes from the meeting held February 7, 2018 BE ADOPTED.
Carried Unanimously
D.
New Business
D.1
D.2
Review and Approval of the 2017 Annual Report to Council The Committee reviewed the draft 2017 Annual Report to Council and proposed 2018 Work Plan. Discussion commenced regarding the parameters on how projects are chosen to receive the Certificate of Project Recognition. Ms. Fraser confirmed that so long as the permit has been issued the project can be considered for the award. It was further noted that the project does not need to be completed as many permits have up to two years before completion must be met.
Moved by Ms. Petrovic, seconded by Ms. Parker, that the 2017 Annual Report to Council from the Advisory Committee on Development Design, as attached to the agenda for the February 28, 2018 committee meeting, BE APPROVED.
Carried Unanimously
Ms. Parker and Ms. Fraser will work on a PowerPoint presentation and submit to Ms. Jackson before 12:00 p.m. on Friday, March 2, 2018. Recruitment for Committee Membership
Ms. Jackson reminded the Committee the application deadline to volunteer on the Advisory Committee on Development Design or Advisory Committee on Accessibility is 5:00 p.m. on Monday, March 19, 2018.
E. Adjournment
THE ADVISORY COMMITTEE ON DEVELOPMENT DESIGN MEETING ADJOURNED AT 12:18 p.m.
__________________________________ Ms. Linda Parker, Chair
__________________________________
Ms. Leslie Jackson, Legislative Coordinator
__________________________________ CERTIFIED CORRECT
UP
DN
MANHOLE
PRO
PER
TY L
INE
108'
-0"
PROPERTY LINE 61'-3"
PRO
PER
TY L
INE
108'
-0"
PROPERTY LINE 61'-3"
1 6
7 8
9
S/C2 3 4 5
OFFSET LINE
CS
CS
ENTRANCE
VA
NC
OU
VE
R S
TRE
ET
8TH AVENUE
LANE
EX. SIDEWALK
EX.
SID
EW
ALK
TP
EXISTING FENCETO BE REPLACEDWITH NEW FENCEALONG P.L.
PEDESTRIAN GATE CO
NC
RET
E SI
DEW
ALK
PARKING
FLAT ROOFOVERHANG
PROPOSED BUILDING274.4m2 (2952 sq. ft.)
PARKING
MAIN ENTRYCONCRETEWALKWAY
COVEREDPATIO
SNOWSTORAGE
L.S.
L.S.
L.S.
NEW CITY LIGHTSSEE ELECTRICAL
BIKE RACK(2 SPACES REQ'D)
EXISTING ELM TREETREE DIA 600 MMTO BE RETAINED
MAIN ENTRY PORCH,BRUSHED CONCRETESURFACE
PLANTER FORSEASONAL GARDENINGOPPORTUNITES CW600MM DEPTH GROWINGMEDIUM. APPROX HEIGHT450MM OFF PATIO /DRAINROCK SURFACE
BOLLARD LIGHT
FLAT ROOFOVERHANG
24" x 24" PRECASTCONCRETE PAVERS
EXISTING ELM TREETREE DIA 750 MMTO BE RETAINED
ENTRANCE
47' - 0"
15' -
0"
73' -
0"
LANE
PRO
PER
TY L
INE
108'
-0"
TELEPHONE POLE
TELEPHONE POLE
7 8
GATE
SID
EWAL
K
NEW FENCE ALONG P.L.
PATIO
TELEPHONE POLE
C.B.
NEW R.C.
C.B.
20' -
0"
LEGAL DESCRIPTION
PARCEL D (BEING A CONSOLIDATION OF LOTS 13 & 14 , SEE CA6324065) DISTRICT LOT 343, BLOCK 180, PLAN 1268, PID 030-272-131
CIVIC ADDRESS
1616 8TH AVENUE PRINCE GEORGE, B.C. ZONING C8
OCCUPANCY D - OFFICE & C - RESIDENTIAL
THIS BUILDING CONFORMS TO BRITISH COLUMBIABUILDING CODE 2012.
BUILDING DESIGNED UNDER PART 9 SECTIONS:
* SEE ATTACHED CODE ANALYSIS*
OCCUPANCY LOAD
OFFICE - 26 RESIDENCE -4
SQUARE FOOTAGES
SITE 609m2 (6555 sq. ft.) BASEMENT 70.1m2 (754 sq. ft.) MAIN FLOOR 274.41m2 (2953 sq. ft.) 2ND FLOOR 129.24m2 (1391 sq. ft.)
TOTAL COMMERICAL AREA: 234.95m² (2529 sq. ft.)
TOTAL RESIDENTIAL AREA: 238.83m² (2570 sq. ft.)(SECURITY OPERATOR UNIT)
SITE & BUILDING INFORMATION NUMBER OF STREETS 3 SITE COVERAGE 45% NUMBER OF STORIES 2 NUMBER OF EXITS 3 NUMBER OF W/C'S 2 COMBUSTIBLE CONSTRUCTION YES SPRINKLER SYSTEM REQUIRED NO STANDPIPE REQUIRED NO FIRE ALARM SYSTEM REQUIRED NO
FIRE RESISTANCE RATINGS FLOORS TYP. 1 HR EXTERIOR WALLS 1 HR EXIT STAIRS 1 HR SERVICE ROOM 1 HR STORAGE ROOF 45 min. ROOF N/A
PARKING:SECURITY OPERATOR UNIT - 1OFFICE 3.4/100m²x235m² = 7.99 => 8TOTAL STALLS = 9
LOADING:N/A (BUSINESS) - SEE TABLE 7.5 OF ZONING BL7850
BICYCLE PARKING:OFFICE 2 PER BLDG W/ < 500m² GFA
SITE & BUILDING INFORMATION
14
84
2N
D A
VE
NU
E
V2
L 3
B6
FA
X: 5
63-4
878
TE
L: 5
62
-93
45
PR
INC
E G
EO
RG
E, B
. C
.
DAT
E
ACAD
FIL
ED
WG
NO
.
DR
AWN
BY
PRO
J. N
O.
SCAL
E
CLI
ENT
PRO
JEC
T
DW
G T
ITLE
REV
ISIO
NS
chec
ked
chec
ked
ENG
INEE
R'S
SEA
LD
ATE
ISSU
EDE
NG
INE
ER
ING
CO
NS
UL
TA
NT
S L
TD
.
Con
tract
ors
shal
l ver
ify a
nd b
eres
pons
ible
for a
ll dim
ensio
ns a
nd c
ondi
tions
Writ
ten
dim
ensio
ns s
hall h
ave
prec
eden
ce o
ver s
cale
d di
men
sions
.fo
r cor
rect
ion,
inte
rpre
tatio
n or
revis
ion.
Disc
repa
ncie
s, e
rrors
and
om
issio
ns s
hall b
e re
ferre
d to
the
Con
sulta
ntTh
is dr
awin
g an
d th
e co
pyrig
ht a
re th
e pr
oper
ty o
f the
EN
GIN
EER
.
show
n on
the
draw
ings
. Sho
p dr
awin
gs s
hall b
e su
bmitt
ed to
the
Con
sulta
nt fo
r app
rova
l bef
ore
proc
eedi
ng w
ith fa
bric
atio
n.En
gine
er's
Seal
App
lies
toSt
ruct
ural
Det
ails
Onl
y
NO
.D
ATE
EXPL
ANAT
ION
CO
-DES
IGN
ER
ARC
HIT
ECTU
RAL
DES
IGN
ENG
INEE
RIN
G D
ESIG
NAs
indi
cate
d
Site
Pla
nAc
cess
Eng
inee
ring
Con
sulta
nts
Ltd
1714
1
Ow
ner
A0
Mar
8, 2
018
S. G
ibso
nBr
uce
John
ston
, P. E
ng.
-
1/8" = 1'-0"A01 Site Plan
Residential Area
Basement Storage 70.123 m² 755 ft²Storage Area 39.470 m² 425 ft²Suite Area 129.242 m² 1391 ft²
238.834 m² 2571 ft²
Commercial Area
Office Area 234.946 m² 2529 SF234.946 m² 2529 SF
0102
/6/1
8IS
SUED
FO
R D
EVEL
OPM
ENT
PER
MIT
- 1 3/4" GYPSUM CONC. TOPPING- 3/4" T&G PLYWOOD- 11 7/8" TJI JOISTS @ 16" O/C- RESILIENT CHANNEL @ 16" O/C- 2 LAYER 5/8" TYPE "X" GWB
FL1
FLOOR SCHEDULE
(F15a) FFR 1 HR STC 57
- 5/8" T&G PLYWOOD- 2x4 STRAPPING @ 16" O/C- 11 7/8" TJI JOISTS @ 16" O/C- BATT INSULATION- 1 LAYER 5/8" TYPE "X" GWB
FL2
(F10c) FFR 45 HR STC 51
R1
ROOF SCHEDULE
- 2 PLY SBS ROOF MEMBRANE- SLOPE KIT (FOR DRAINAGE)- 5/8" T&G PLYWOOD- 2x4 STRAPPING @ 16" O/C- 11 7/8" TJI JOISTS @ 16" O/C- BATT INSULATION- 1 1/2" SILVERBOARD (EPS)- VAPOUR BARRIER- 1 LAYER 5/8" GWB
R2
- 2 PLY SBS ROOF MEMBRANE- SLOPE KIT (FOR DRAINAGE)- 5/8" T&G PLYWOOD- 24" DP ENGINEERED TRUSSES
@ 24" O/C TYP.- BLOWN IN & BATT INSULATION- VAPOUR BARRIER- 1 LAYER 5/8" GWB
- 5/16" HARDIE PANEL OR LAP SIDING- 1X4 STRAPPING @ 16" O/C- BUILDING WRAP- 1 1/2" RIGID INSULATION (EPS)- 1/2" PLYWOOD SHEATHING- 2x6 STUDS @ 16" O/C TYP.- R24 BATT INSULATION- VAPOUR BARRIER- 1/2" GYPSUM WALL BOARD
- 5/16" HARDIE PANEL OR LAP SIDING- 1x4 STRAPPING @ 16" O/C- BUILDING WRAP- 1/2" EXTERIOR GWB- 6" CONC. ICF WALL R28 (11.25" THK)- VAPOUR BARRIER- 1/2" GYPSUM WALL BOARD
- 5/8" TYPE "X" GWB- 2x6 STUDS @ 16" O/C TYP.- ROCKWOOL SAFE n SOUND- 5/8" TYPE "X" GWB
- 1/2" GWB- 2x4 STUDS @ 16" O/C TYP.- ROCKWOOL SAFE n SOUND- 1/2" GWB
EW1
EW2
W1a
W2
- 1/2" GWB- 2x4 STUDS @ 16" O/C TYP.- 1/2" GWB
W3
WALL SCHEDULE
Roof Insulation- Standard Truss
Roof - Raised Heel Scissor TrussTruss Bottom chord dimensional lumber - 38mm x 89mm (2"X4") with RSI = 0.757m²K/WElementContinuous Material
DetailsRoof Sheathing
Table Effective RSIn/a 0.00
Continuous Material Vented Roof Air Space CM-1 0.03Continuous Material Blown -in insulation for attics, 268mm
at 0.025 RSI/mmCM-1 6.7
Frame Cavity Roof truss bottom chord dimensional lumber: 38 mm x 89 mm (2x4) spruce @ 610 mm (24") c/c, R-12 nominal cavity fill between trusses
CM-1 1.76
Continuous Material Gypsum board, 12.7mm (1/2") at 0.0063 RSI/mm
CM-1 0.08
Continuous Material Air Film interior, Ceiling (heat flow up) CM-1 0.11
Total: 8.68 > 4.67 Req'd
Continuous Material Polyethylene Vapour Retarder n/a 0.00
Typical Exterior Walls - 2x6 @ 16" c/c w/out HRVWall Above and Not in Contact with Ground - Lumber Studs
Wall Stud dimensional lumber - 38mm x 140mm (2"X6") with RSI = 1.19 m²K/WElementContinuous Material
DetailsAir Film Exterior
Table Effective RSICM-1 0.03
Continuous Material Siding - Fibre Cement CM-1 0.024
Continuous Material Plywood sheathing - 1/2" at 0.0087 RSI/mm
CM-1 0.11
Frame Cavity Stud dimensional lumber: 38 mm x 140 mm (2"x6"), 406 mm (16") on-centre, RSI 4.23 (R24) nominal cavity fill between studs
WA-2 2.66
Continuous Material Polyethylene Vapour Retarder n/a 0.00Continuous Material Gypsum board, 12.7mm (5/8") at
0.0063 RSI/mmCM-1 0.08
Continuous Material Air Film interior, Wall (heat flow up) CM-1 0.12
Total: 4.014 > 3.08 Req'd
Continuous Material Extruded Polystyrene (XPS)38mm at 0.026 RSI/mm
CM-1 0.99Continuous Material 3/4" Air space CM-1 0.00
Unheated Floor Above Frost Line - (XPS)Wall Below and in Contact with Ground
Concrete Slab ElementContinuous Material
DetailsAir Film interior, Floor (heat flow down)
Table Effective RSICM-1 0.16
Concrete Concrete floor slab 100mm (4") at0.0004 RSI/mm
CM-1 0.04
Insulation Extruded Polystyrene (XPS), 76mm (3") at 0.035 RSI/mm
CM-1 2.66
Total: 2.86 > 1.96 Req'd
Foundation Wall - 6" ICF Wall Below and in Contact with Ground
Element
Continuous Material
Details
Concrete - 152mm at 0.0004 RSI/mm
Table Effective RSI
CM-1 0.06Frame Cavity Type 2 EPS, 79mm at 0.028 RSI/mm CM-1 2.21Continuous Material Polyethylene Vapour Retarder n/a 0.00Continuous Material Gypsum board, 12.7mm (5/8") at
0.0063 RSI/mmCM-1 0.08
Continuous Material Air Film interior, Wall (heat flow Horiz) CM-1 0.12
Total: 4.71 > 2.98 Req'd
Foundation Wall - 6" ICF Cast-in-place
Continuous Material Expanded polystyrene (Type 2 EPS) -79mm at 0.028 RSI/mm
CM-1 2.21Continuous Material Air Film Exterior CM-1 0.03
Roof Insulation- Cathedral Ceiling/ Flat Roofs - w/ HRVRoof - Cathedral Ceiling
Roof - Lumber Joists - 302mm I-joist (11 7/8" ) with RSI = 2.56m²K/W through webElementContinuous Material
DetailsRoof Sheathing
Table Effective RSIn/a 0.00
Continuous Material Vented Roof Air Space CM-1 0.03Frame Cavity Cathedral Ceiling - I-Joists :
302mm deep @ 406mm (16")c/cRSI 5.64 (R32) 8" nominal cavity fillthrough webs
R2-2 5.09
Continuous Material Polyethylene Vapour Retarder n/a 0.00Continuous Material Gypsum board, 12.7mm (1/2") at
0.0063 RSI/mmCM-1 0.08
Continuous Material Air Film interior, Ceiling (heat flow up) CM-1 0.11
Total: 6.3 > 4.67 Req'd
Continuous Material Silverboard Expanded Polystyrene (EPS)38mm at 0.026 RSI/mm
CM-1 0.99
NOTES1) Roof sheathing: is to the exterior of the vented roof air space, therefore excluded from calculation. 2) Polyethylene vapour retarder: negligible contribution to effective thermal resistance.
14
84
2N
D A
VE
NU
E
V2
L 3
B6
FA
X: 5
63-4
878
TE
L: 5
62
-93
45
PR
INC
E G
EO
RG
E, B
. C
.
DAT
E
ACAD
FIL
ED
WG
NO
.
DR
AWN
BY
PRO
J. N
O.
SCAL
E
CLI
ENT
PRO
JEC
T
DW
G T
ITLE
REV
ISIO
NS
chec
ked
chec
ked
ENG
INEE
R'S
SEA
LD
ATE
ISSU
EDE
NG
INE
ER
ING
CO
NS
UL
TA
NT
S L
TD
.
Con
tract
ors
shal
l ver
ify a
nd b
eres
pons
ible
for a
ll dim
ensio
ns a
nd c
ondi
tions
Writ
ten
dim
ensio
ns s
hall h
ave
prec
eden
ce o
ver s
cale
d di
men
sions
.fo
r cor
rect
ion,
inte
rpre
tatio
n or
revis
ion.
Disc
repa
ncie
s, e
rrors
and
om
issio
ns s
hall b
e re
ferre
d to
the
Con
sulta
ntTh
is dr
awin
g an
d th
e co
pyrig
ht a
re th
e pr
oper
ty o
f the
EN
GIN
EER
.
show
n on
the
draw
ings
. Sho
p dr
awin
gs s
hall b
e su
bmitt
ed to
the
Con
sulta
nt fo
r app
rova
l bef
ore
proc
eedi
ng w
ith fa
bric
atio
n.En
gine
er's
Seal
App
lies
toSt
ruct
ural
Det
ails
Onl
y
NO
.D
ATE
EXPL
ANAT
ION
CO
-DES
IGN
ER
ARC
HIT
ECTU
RAL
DES
IGN
ENG
INEE
RIN
G D
ESIG
NAs
indi
cate
d
Gen
eral
Not
es &
Sch
edul
esAc
cess
Eng
inee
ring
Con
sulta
nts
Ltd
1714
1
Ow
ner
A1.1
Feb
6, 2
018
S. G
ibso
nBr
uce
John
ston
, P. E
ng.
Che
cker
0102
/6/1
8IS
SUED
FO
R D
EVEL
OPM
ENT
PER
MIT
UP
DN
DW
REF
.
11' - 10 3/4" 4' - 6 1/2"
12' -
0"
22' - 8"
4' -
0"
1' -
10"
14' -
2"
1' -
10"
6' - 0"
13' -
1 1
/2"
14' -
2 1
/2"
24' -
2"
2' -
6"
17' - 4 1/2" 29' - 7 1/2"
2' - 0" 10' - 0" 2' - 0" 3' - 4 1/2"
47' - 0"
1' - 4 1/2" 8' - 0" 1' - 5" 8' - 0" 1' - 5" 8' - 0" 1' - 5"
10' -
0"
3' -
6"10
' - 0
"
2' - 0" 8' - 0" 6' - 6" 8' - 0" 6' - 6" 8' - 0"
3' -
0"10
' - 0
"3'
- 0"
7' -
8"
AA5.1
BA5.1
CA5.1
DA5.2
EA5.2
Suite Garage
Workstations
Layout Area
Waiting AreaReception
ACCESS W/C
Board Room
W/C
2' - 6" 3' - 4" 2' - 6" 3' - 4 1/2" 2' - 6" 2' - 6" 3' - 4 1/2" 2' - 6" 3' - 4"
5' -
0"3' - 6" 5' - 0"
PLO
TTER
(50"
wX3
0"D
)
PRIN
TER
DRAWINGRACKS
Staff Room
2' - 6" 4' - 0" 3' - 6" 4' - 6 1/2" 2' - 6"
Bruce Office
4' -
0"
9' - 10 1/2" 9' - 10 1/2"
OfficeOfficeOffice Office
ELEC.METERS
4' - 1 1/4"
4
5
321
14
13 11 10
9
8
7
6
7' -
6"3'
- 1"
5
1110 2
3
4
14 13
16
12
1
8
15
6' - 0"
5' - 0"
9
6
Hallway
4' -
0"
1' -
0"
5' -
2 1/
2"
2' -
0"
JAN.
MECH. ROOM
CLEANING
COATS
7
68' -
0"
2' -
0"
25' -
6"
24' -
8"
1' -
0"
3' -
6"
4' -
0"10
' - 0
"
14
84
2N
D A
VE
NU
E
V2
L 3
B6
FA
X: 5
63-4
878
TE
L: 5
62
-93
45
PR
INC
E G
EO
RG
E, B
. C
.
DAT
E
ACAD
FIL
ED
WG
NO
.
DR
AWN
BY
PRO
J. N
O.
SCAL
E
CLI
ENT
PRO
JEC
T
DW
G T
ITLE
REV
ISIO
NS
chec
ked
chec
ked
ENG
INEE
R'S
SEA
LD
ATE
ISSU
EDE
NG
INE
ER
ING
CO
NS
UL
TA
NT
S L
TD
.
Con
tract
ors
shal
l ver
ify a
nd b
eres
pons
ible
for a
ll dim
ensio
ns a
nd c
ondi
tions
Writ
ten
dim
ensio
ns s
hall h
ave
prec
eden
ce o
ver s
cale
d di
men
sions
.fo
r cor
rect
ion,
inte
rpre
tatio
n or
revis
ion.
Disc
repa
ncie
s, e
rrors
and
om
issio
ns s
hall b
e re
ferre
d to
the
Con
sulta
ntTh
is dr
awin
g an
d th
e co
pyrig
ht a
re th
e pr
oper
ty o
f the
EN
GIN
EER
.
show
n on
the
draw
ings
. Sho
p dr
awin
gs s
hall b
e su
bmitt
ed to
the
Con
sulta
nt fo
r app
rova
l bef
ore
proc
eedi
ng w
ith fa
bric
atio
n.En
gine
er's
Seal
App
lies
toSt
ruct
ural
Det
ails
Onl
y
NO
.D
ATE
EXPL
ANAT
ION
CO
-DES
IGN
ER
ARC
HIT
ECTU
RAL
DES
IGN
ENG
INEE
RIN
G D
ESIG
N 1
/4" =
1'-0
"
Mai
n Fl
oor P
lan
Acce
ss E
ngin
eerin
g C
onsu
ltant
s Lt
d
1714
1
Ow
ner
A2.1
Feb
6, 2
018
S. G
ibso
nBr
uce
John
ston
, P. E
ng.
Che
cker
1/4" = 1'-0"A2.11 Main Floor Plan
Window Schedule
Mark Sill Height Width Height Area
1 2' - 6" 8' - 0" 5' - 6" 44.000 SF2 2' - 6" 8' - 0" 5' - 6" 44.000 SF3 2' - 6" 8' - 0" 5' - 6" 44.000 SF4 2' - 6" 3' - 0" 5' - 6" 16.500 SF5 2' - 6" 3' - 0" 5' - 6" 16.500 SF6 1' - 6" 7' - 6" 6' - 6" 48.750 SF7 1' - 6" 3' - 0" 6' - 6" 19.500 SF8 2' - 6" 10' - 0" 7' - 6" 75.000 SF9 2' - 6" 10' - 0" 7' - 6" 75.000 SF10 2' - 6" 8' - 0" 7' - 6" 60.000 SF11 2' - 6" 8' - 0" 7' - 6" 60.000 SF13 2' - 6" 8' - 0" 7' - 6" 60.000 SF14 2' - 0" 6' - 0" 6' - 0" 36.000 SF15 6' - 0" 6' - 0" 1' - 4" 8.000 SF16 1' - 6" 8' - 0" 6' - 6" 52.000 SF17 1' - 6" 8' - 0" 6' - 6" 52.000 SF18 1' - 6" 3' - 0" 6' - 6" 19.500 SF19 1' - 6" 3' - 0" 6' - 6" 19.500 SF20 5' - 0" 3' - 0" 3' - 0" 9.000 SF21 1' - 6" 3' - 6" 6' - 6" 22.750 SF22 5' - 0" 2' - 0" 2' - 0" 4.000 SF23 5' - 0" 2' - 0" 2' - 0" 4.000 SF24 5' - 0" 2' - 0" 2' - 0" 4.000 SF25 1' - 6" 6' - 0" 6' - 6" 39.000 SF26 1' - 6" 3' - 0" 6' - 6" 19.500 SF27 1' - 6" 3' - 0" 6' - 6" 19.500 SF
Door Schedule
Mark Width Height Fire Rating Comments
1 3' - 0" 8' - 0" No2 3' - 0" 8' - 0"3 4' - 0" 8' - 0"4 4' - 0" 8' - 0"5 3' - 0" 8' - 0"6 3' - 0" 7' - 0" Yes 45 Min. Rated Door & Frame7 2' - 8" 7' - 0"8 3' - 0" 7' - 0"9 2' - 8" 7' - 0"10 3' - 0" 7' - 0"11 3' - 0" 7' - 0"12 3' - 0" 7' - 0"13 3' - 0" 7' - 0" Yes 45 Min. Rated Door & Frame14 3' - 0" 7' - 0" Yes 45 Min. Rated Door & Frame c/w
Weather Stripping & Close15 10' - 0" 8' - 0"16 3' - 0" 8' - 0"17 3' - 0" 7' - 0" Yes C/W Weather Stripping & Closer18 4' - 0" 7' - 0"19 3' - 0" 7' - 0"20 2' - 6" 7' - 0"21 2' - 6" 7' - 0"22 2' - 6" 7' - 0"23 2' - 8" 7' - 0"24 4' - 0" 7' - 0"25 2' - 8" 7' - 0"26 2' - 6" 7' - 0"27 2' - 6" 7' - 0"28 2' - 2" 7' - 0"29 3' - 0" 7' - 0"
0102
/6/1
8IS
SUED
FO
R D
EVEL
OPM
ENT
PER
MIT
DN
DW
70.096 m²
Storage131
13' - 6" 14' - 0" 13' - 6"
9' - 4" 8' - 2" 14' - 10" 6' - 8"
17' - 6" 29' - 6"
47' - 0"
2' -
6"24
' - 0
"14
' - 6
"13
' - 0
"14
' - 0
"
68' -
0"
6' - 0" 41' - 0"
14' -
2"
12' -
6 3
/4"
14' -
9 1
/4"
26' -
6"
41' -
6"
68' -
0"
4' -
6"19
' - 6
"
8' - 0"
12' - 9" 4' - 9"
5' -
6 1/
4"8'
- 6"
3' -
5 1/
4"
3' -
1"3'
- 6
1/2"
7' -
6 1/
2"
AA5.1
BA5.1
CA5.1
DA5.2 E
A5.2
Bedroom
Patio
Lower Roof
38' - 11 1/2"
4' - 10"
15' -
4"
8' - 0" 10' - 10" 8' - 0"
3 1/
2"3'
- 0"
4' -
4 1/
2"3'
- 0"
10' -
0"
3' -
0"
5' - 11 3/4" 2' - 0" 8' - 1 1/2" 2' - 0" 9' - 6" 2' - 0" 8' - 7 1/4" 9"
BENCHW D
12' - 2"
4' - 0"
17
18
20
26
19
29
22
26
27
16 17
18
19
20
21
25
5' -
8 1/
2"6'
- 0"
4' -
0 1/
2"
15' -
9"
ON DEMANDHOT WATER
Mech.
23
22
21
25
3' - 6"
4' -
0"
21' - 3"
4' -
6 1/
2"
6"
244' - 0"
benchhanging
shoes
9' -
6 1/
2"
12' - 10" 8' - 5"
linen
2324
shower
4' -
6"
Walk-in Closet
Room
Ensuite
10" 2'
- 2
1/2"
1' -
6"
3' -
11"
5' -
7 1/
2"
27
28
14
84
2N
D A
VE
NU
E
V2
L 3
B6
FA
X: 5
63-4
878
TE
L: 5
62
-93
45
PR
INC
E G
EO
RG
E, B
. C
.
DAT
E
ACAD
FIL
ED
WG
NO
.
DR
AWN
BY
PRO
J. N
O.
SCAL
E
CLI
ENT
PRO
JEC
T
DW
G T
ITLE
REV
ISIO
NS
chec
ked
chec
ked
ENG
INEE
R'S
SEA
LD
ATE
ISSU
EDE
NG
INE
ER
ING
CO
NS
UL
TA
NT
S L
TD
.
Con
tract
ors
shal
l ver
ify a
nd b
eres
pons
ible
for a
ll dim
ensio
ns a
nd c
ondi
tions
Writ
ten
dim
ensio
ns s
hall h
ave
prec
eden
ce o
ver s
cale
d di
men
sions
.fo
r cor
rect
ion,
inte
rpre
tatio
n or
revis
ion.
Disc
repa
ncie
s, e
rrors
and
om
issio
ns s
hall b
e re
ferre
d to
the
Con
sulta
ntTh
is dr
awin
g an
d th
e co
pyrig
ht a
re th
e pr
oper
ty o
f the
EN
GIN
EER
.
show
n on
the
draw
ings
. Sho
p dr
awin
gs s
hall b
e su
bmitt
ed to
the
Con
sulta
nt fo
r app
rova
l bef
ore
proc
eedi
ng w
ith fa
bric
atio
n.En
gine
er's
Seal
App
lies
toSt
ruct
ural
Det
ails
Onl
y
NO
.D
ATE
EXPL
ANAT
ION
CO
-DES
IGN
ER
ARC
HIT
ECTU
RAL
DES
IGN
ENG
INEE
RIN
G D
ESIG
N 1
/4" =
1'-0
"
Basm
ent &
Sec
ond
Floo
r Pla
nAc
cess
Eng
inee
ring
Con
sulta
nts
Ltd
1714
1
Ow
ner
A2.2
Feb
6, 2
018
S. G
ibso
nBr
uce
John
ston
, P. E
ng.
Che
cker
1/4" = 1'-0"A2.21 Basement
1/4" = 1'-0"A2.22 Second Floor Plan
Residential Area
Garage Area 39.470 m² 425 ft²Storage 70.123 m² 755 ft²Suite Area 129.242 m² 1391 ft²
238.834 m² 2571 ft²
0102
/6/1
8IS
SUED
FO
R D
EVEL
OPM
ENT
PER
MIT
14
84
2N
D A
VE
NU
E
V2
L 3
B6
FA
X: 5
63-4
878
TE
L: 5
62
-93
45
PR
INC
E G
EO
RG
E, B
. C
.
DAT
E
ACAD
FIL
ED
WG
NO
.
DR
AWN
BY
PRO
J. N
O.
SCAL
E
CLI
ENT
PRO
JEC
T
DW
G T
ITLE
REV
ISIO
NS
chec
ked
chec
ked
ENG
INEE
R'S
SEA
LD
ATE
ISSU
EDE
NG
INE
ER
ING
CO
NS
UL
TA
NT
S L
TD
.
Con
tract
ors
shal
l ver
ify a
nd b
eres
pons
ible
for a
ll dim
ensio
ns a
nd c
ondi
tions
Writ
ten
dim
ensio
ns s
hall h
ave
prec
eden
ce o
ver s
cale
d di
men
sions
.fo
r cor
rect
ion,
inte
rpre
tatio
n or
revis
ion.
Disc
repa
ncie
s, e
rrors
and
om
issio
ns s
hall b
e re
ferre
d to
the
Con
sulta
ntTh
is dr
awin
g an
d th
e co
pyrig
ht a
re th
e pr
oper
ty o
f the
EN
GIN
EER
.
show
n on
the
draw
ings
. Sho
p dr
awin
gs s
hall b
e su
bmitt
ed to
the
Con
sulta
nt fo
r app
rova
l bef
ore
proc
eedi
ng w
ith fa
bric
atio
n.En
gine
er's
Seal
App
lies
toSt
ruct
ural
Det
ails
Onl
y
NO
.D
ATE
EXPL
ANAT
ION
CO
-DES
IGN
ER
ARC
HIT
ECTU
RAL
DES
IGN
ENG
INEE
RIN
G D
ESIG
N 1
/4" =
1'-0
"
Ref
lect
ed C
eilin
g Pl
ans
Acce
ss E
ngin
eerin
g C
onsu
ltant
s Lt
d
1714
1
Ow
ner
A3.1
Feb
6, 2
018
S. G
ibso
nBr
uce
John
ston
, P. E
ng.
Che
cker
1/4" = 1'-0"A3.11 Main Floor Reflected Ceiling
1/4" = 1'-0"A3.12 Basement Reflected Ceiling
1/4" = 1'-0"A3.13 Second Floor Reflected Ceiling Plan
0102
/6/1
8IS
SUED
FO
R D
EVEL
OPM
ENT
PER
MIT
Level 10"
Level 211' - 3 1/4"
u/s truss 320' - 4 3/8"
1 2 3
171626
Level 10"
Level 10"
Level 211' - 3 1/4"
u/s truss 320' - 4 3/8"
u/s truss 112' - 0"
18
4 5
19
20
6 7
21
8 9
14
84
2N
D A
VE
NU
E
V2
L 3
B6
FA
X: 5
63-4
878
TE
L: 5
62
-93
45
PR
INC
E G
EO
RG
E, B
. C
.
DAT
E
ACAD
FIL
ED
WG
NO
.
DR
AWN
BY
PRO
J. N
O.
SCAL
E
CLI
ENT
PRO
JEC
T
DW
G T
ITLE
REV
ISIO
NS
chec
ked
chec
ked
ENG
INEE
R'S
SEA
LD
ATE
ISSU
EDE
NG
INE
ER
ING
CO
NS
UL
TA
NT
S L
TD
.
Con
tract
ors
shal
l ver
ify a
nd b
eres
pons
ible
for a
ll dim
ensio
ns a
nd c
ondi
tions
Writ
ten
dim
ensio
ns s
hall h
ave
prec
eden
ce o
ver s
cale
d di
men
sions
.fo
r cor
rect
ion,
inte
rpre
tatio
n or
revis
ion.
Disc
repa
ncie
s, e
rrors
and
om
issio
ns s
hall b
e re
ferre
d to
the
Con
sulta
ntTh
is dr
awin
g an
d th
e co
pyrig
ht a
re th
e pr
oper
ty o
f the
EN
GIN
EER
.
show
n on
the
draw
ings
. Sho
p dr
awin
gs s
hall b
e su
bmitt
ed to
the
Con
sulta
nt fo
r app
rova
l bef
ore
proc
eedi
ng w
ith fa
bric
atio
n.En
gine
er's
Seal
App
lies
toSt
ruct
ural
Det
ails
Onl
y
NO
.D
ATE
EXPL
ANAT
ION
CO
-DES
IGN
ER
ARC
HIT
ECTU
RAL
DES
IGN
ENG
INEE
RIN
G D
ESIG
N 1
/4" =
1'-0
"
Exte
rior E
leva
tions
Acce
ss E
ngin
eerin
g C
onsu
ltant
s Lt
d
1714
1
Ow
ner
A4.1
Feb
6, 2
018
S. G
ibso
nBr
uce
John
ston
, P. E
ng.
Che
cker
1/4" = 1'-0"A4.11 8th Aveune Elevation
1/4" = 1'-0"A4.12 Vancouver St Elevation
A4.13 Perspective 1
A4.14 Perspective 2
0102
/6/1
8IS
SUED
FO
R D
EVEL
OPM
ENT
PER
MIT
Level 10"
u/s joist 210' - 0 7/8"
u/s truss 320' - 4 3/8"
u/s truss 112' - 0"
22
131110
23 24
Level 10"
Level 10"
u/s joist 210' - 0 7/8"
Level 211' - 3 1/4"
u/s truss 320' - 4 3/8"
u/s truss 112' - 0"
25
14
105
19
27
u/s Joists1-1' - 2 3/8"
15
14
84
2N
D A
VE
NU
E
V2
L 3
B6
FA
X: 5
63-4
878
TE
L: 5
62
-93
45
PR
INC
E G
EO
RG
E, B
. C
.
DAT
E
ACAD
FIL
ED
WG
NO
.
DR
AWN
BY
PRO
J. N
O.
SCAL
E
CLI
ENT
PRO
JEC
T
DW
G T
ITLE
REV
ISIO
NS
chec
ked
chec
ked
ENG
INEE
R'S
SEA
LD
ATE
ISSU
EDE
NG
INE
ER
ING
CO
NS
UL
TA
NT
S L
TD
.
Con
tract
ors
shal
l ver
ify a
nd b
eres
pons
ible
for a
ll dim
ensio
ns a
nd c
ondi
tions
Writ
ten
dim
ensio
ns s
hall h
ave
prec
eden
ce o
ver s
cale
d di
men
sions
.fo
r cor
rect
ion,
inte
rpre
tatio
n or
revis
ion.
Disc
repa
ncie
s, e
rrors
and
om
issio
ns s
hall b
e re
ferre
d to
the
Con
sulta
ntTh
is dr
awin
g an
d th
e co
pyrig
ht a
re th
e pr
oper
ty o
f the
EN
GIN
EER
.
show
n on
the
draw
ings
. Sho
p dr
awin
gs s
hall b
e su
bmitt
ed to
the
Con
sulta
nt fo
r app
rova
l bef
ore
proc
eedi
ng w
ith fa
bric
atio
n.En
gine
er's
Seal
App
lies
toSt
ruct
ural
Det
ails
Onl
y
NO
.D
ATE
EXPL
ANAT
ION
CO
-DES
IGN
ER
ARC
HIT
ECTU
RAL
DES
IGN
ENG
INEE
RIN
G D
ESIG
N 1
/4" =
1'-0
"
Exte
rior E
leva
tions
Acce
ss E
ngin
eerin
g C
onsu
ltant
s Lt
d
1714
1
Ow
ner
A4.2
Feb
6, 2
018
S. G
ibso
nBr
uce
John
ston
, P. E
ng.
Che
cker
1/4" = 1'-0"A4.21 Lane Elevation
1/4" = 1'-0"A4.22 Side Elevation
A4.23 Perspective 3
A4.24 Perspective 4
0102
/6/1
8IS
SUED
FO
R D
EVEL
OPM
ENT
PER
MIT
Level 10"
Level 211' - 3 1/4"
u/s truss 320' - 4 3/8"
T.O. Ftg 2-8' - 8"
11' -
0 1
/2"
Suite Garage
Patio
Workstations
11 7
/8"
6' -
11 7
/8"
9' -
6 7/
8"
9' -
4"4'
- 0"
13' -
4"
u/s Joists1-1' - 2 3/8"
4' - 0"
1/8" / 1'-0"1/8" / 1'-0"
9' -
1"
Reception Waiting Area
Bedroom
Level 10"
u/s truss 112' - 0"
T.O. Ftg 1-4' - 0"
Board Room
10' -
1"
11' -
11
3/8"
ACCESS W/C
14
84
2N
D A
VE
NU
E
V2
L 3
B6
FA
X: 5
63-4
878
TE
L: 5
62
-93
45
PR
INC
E G
EO
RG
E, B
. C
.
DAT
E
ACAD
FIL
ED
WG
NO
.
DR
AWN
BY
PRO
J. N
O.
SCAL
E
CLI
ENT
PRO
JEC
T
DW
G T
ITLE
REV
ISIO
NS
chec
ked
chec
ked
ENG
INEE
R'S
SEA
LD
ATE
ISSU
EDE
NG
INE
ER
ING
CO
NS
UL
TA
NT
S L
TD
.
Con
tract
ors
shal
l ver
ify a
nd b
eres
pons
ible
for a
ll dim
ensio
ns a
nd c
ondi
tions
Writ
ten
dim
ensio
ns s
hall h
ave
prec
eden
ce o
ver s
cale
d di
men
sions
.fo
r cor
rect
ion,
inte
rpre
tatio
n or
revis
ion.
Disc
repa
ncie
s, e
rrors
and
om
issio
ns s
hall b
e re
ferre
d to
the
Con
sulta
ntTh
is dr
awin
g an
d th
e co
pyrig
ht a
re th
e pr
oper
ty o
f the
EN
GIN
EER
.
show
n on
the
draw
ings
. Sho
p dr
awin
gs s
hall b
e su
bmitt
ed to
the
Con
sulta
nt fo
r app
rova
l bef
ore
proc
eedi
ng w
ith fa
bric
atio
n.En
gine
er's
Seal
App
lies
toSt
ruct
ural
Det
ails
Onl
y
NO
.D
ATE
EXPL
ANAT
ION
CO
-DES
IGN
ER
ARC
HIT
ECTU
RAL
DES
IGN
ENG
INEE
RIN
G D
ESIG
N 1
/4" =
1'-0
"
Build
ing
Sect
ions
Acce
ss E
ngin
eerin
g C
onsu
ltant
s Lt
d
1714
1
Ow
ner
A5.1
Feb
6, 2
018
S. G
ibso
nBr
uce
John
ston
, P. E
ng.
Che
cker
1/4" = 1'-0"A5.1A Section A
1/4" = 1'-0"A5.1B Section B
1/4" = 1'-0"A5.1C Section C
0102
/6/1
8IS
SUED
FO
R D
EVEL
OPM
ENT
PER
MIT
Level 10"
Level 10"
Level 211' - 3 1/4"
u/s truss 320' - 4 3/8"
u/s truss 112' - 0"
T.O. Ftg 1-4' - 0"
T.O. Ftg 2-8' - 8"
Patio
Suite Garage
Level 10"
Level 10"
Level 211' - 3 1/4"
u/s truss 219' - 4 3/8"
u/s truss 320' - 4 3/8"
u/s truss 112' - 0"
T.O. Ftg 1-4' - 0"
T.O. Ftg 2-8' - 8"
Bruce OfficeWorkstations Waiting Area
Bedroom
Board Room
14
84
2N
D A
VE
NU
E
V2
L 3
B6
FA
X: 5
63-4
878
TE
L: 5
62
-93
45
PR
INC
E G
EO
RG
E, B
. C
.
DAT
E
ACAD
FIL
ED
WG
NO
.
DR
AWN
BY
PRO
J. N
O.
SCAL
E
CLI
ENT
PRO
JEC
T
DW
G T
ITLE
REV
ISIO
NS
chec
ked
chec
ked
ENG
INEE
R'S
SEA
LD
ATE
ISSU
EDE
NG
INE
ER
ING
CO
NS
UL
TA
NT
S L
TD
.
Con
tract
ors
shal
l ver
ify a
nd b
eres
pons
ible
for a
ll dim
ensio
ns a
nd c
ondi
tions
Writ
ten
dim
ensio
ns s
hall h
ave
prec
eden
ce o
ver s
cale
d di
men
sions
.fo
r cor
rect
ion,
inte
rpre
tatio
n or
revis
ion.
Disc
repa
ncie
s, e
rrors
and
om
issio
ns s
hall b
e re
ferre
d to
the
Con
sulta
ntTh
is dr
awin
g an
d th
e co
pyrig
ht a
re th
e pr
oper
ty o
f the
EN
GIN
EER
.
show
n on
the
draw
ings
. Sho
p dr
awin
gs s
hall b
e su
bmitt
ed to
the
Con
sulta
nt fo
r app
rova
l bef
ore
proc
eedi
ng w
ith fa
bric
atio
n.En
gine
er's
Seal
App
lies
toSt
ruct
ural
Det
ails
Onl
y
NO
.D
ATE
EXPL
ANAT
ION
CO
-DES
IGN
ER
ARC
HIT
ECTU
RAL
DES
IGN
ENG
INEE
RIN
G D
ESIG
N 1
/4" =
1'-0
"
Build
ing
Sect
ions
Acce
ss E
ngin
eerin
g C
onsu
ltant
s Lt
d
1714
1
Ow
ner
A5.2
Feb
6, 2
018
S. G
ibso
nBr
uce
John
ston
, P. E
ng.
Che
cker
1/4" = 1'-0"A5.2D Section D
1/4" = 1'-0"A5.2E Section E
0102
/6/1
8IS
SUED
FO
R D
EVEL
OPM
ENT
PER
MIT
104
S1.1
11 7
/ 8" T
JI J
OIS
TSBY
SU
PPLI
ER
11 7
/ 8" T
JI J
OIS
TSBY
SU
PPLI
ER
5' - 0 1/4" 8' - 9" 8' - 9 7/8" 11' - 7 7/8"
13' -
8 3
/4"
12' -
9 1
/4"
29' - 6"17' - 6"
2' -
6"24
' - 0
"14
' - 6
"13
' - 0
"14
' - 0
"
68' -
0"
9' - 4" 8' - 2" 14' - 10" 6' - 8"
13' - 6" 14' - 0" 13' - 6"
14' -
2"
12' -
6 3
/4"
14' -
9 1
/4"
6' - 0" 41' - 0"
47' - 0"
26' -
6"
41' -
6"
68' -
0"
Eng Beam
R @ 7 11/16"13
Eng
Beam
F1 F1F1
F1F1 F1
F1F1F1
F1F1
F1
SF
SF
SF
SF
SF
SF
SF
SF
SFSF SFSF
SFSF
101
S1.1
100
S1.1
103
S1.1
102
S1.1
Level 10"
T.O. Ftg 1-4' - 0"
4"
4 3/4" 7 1/2"
1' - 0 1/4"
8"
1' - 8"
4" XPS INSULATION
COMPACTEDGRANULAR FILL
Level 10"
4' -
0"8"
1' - 8"
Varie
s
4" XPS INSULATION
Level 10"
T.O. Ftg 2-8' - 8"
u/s Joists1-1' - 2 3/8"
2" m
in.
8' -
4"
6' -
11 7
/8"
4" XPS INSULATION
LVL LEDGER C/WICFVL HANGERS
Level 10"
T.O. Ftg 2-8' - 8"
u/s Joists1-1' - 2 3/8"
4"8'
- 4"
6"
Level 10"
u/s Joists1-1' - 2 3/8"
14
84
2N
D A
VE
NU
E
V2
L 3
B6
FA
X: 5
63-4
878
TE
L: 5
62
-93
45
PR
INC
E G
EO
RG
E, B
. C
.
DAT
E
ACAD
FIL
ED
WG
NO
.
DR
AWN
BY
PRO
J. N
O.
SCAL
E
CLI
ENT
PRO
JEC
T
DW
G T
ITLE
REV
ISIO
NS
chec
ked
chec
ked
ENG
INEE
R'S
SEA
LD
ATE
ISSU
EDE
NG
INE
ER
ING
CO
NS
UL
TA
NT
S L
TD
.
Con
tract
ors
shal
l ver
ify a
nd b
eres
pons
ible
for a
ll dim
ensio
ns a
nd c
ondi
tions
Writ
ten
dim
ensio
ns s
hall h
ave
prec
eden
ce o
ver s
cale
d di
men
sions
.fo
r cor
rect
ion,
inte
rpre
tatio
n or
revis
ion.
Disc
repa
ncie
s, e
rrors
and
om
issio
ns s
hall b
e re
ferre
d to
the
Con
sulta
ntTh
is dr
awin
g an
d th
e co
pyrig
ht a
re th
e pr
oper
ty o
f the
EN
GIN
EER
.
show
n on
the
draw
ings
. Sho
p dr
awin
gs s
hall b
e su
bmitt
ed to
the
Con
sulta
nt fo
r app
rova
l bef
ore
proc
eedi
ng w
ith fa
bric
atio
n.En
gine
er's
Seal
App
lies
toSt
ruct
ural
Det
ails
Onl
y
NO
.D
ATE
EXPL
ANAT
ION
CO
-DES
IGN
ER
ARC
HIT
ECTU
RAL
DES
IGN
ENG
INEE
RIN
G D
ESIG
NAs
indi
cate
d
Foun
datio
n Pl
an &
Det
ails
Acce
ss E
ngin
eerin
g C
onsu
ltant
s Lt
d
1714
1
Ow
ner
S1.1
Feb
6, 2
018
S. G
ibso
nBr
uce
John
ston
, P. E
ng.
Che
cker
1/4" = 1'-0"S1.11 Foundation Plan
3/4" = 1'-0"S1.1100 Detail 100
3/4" = 1'-0"S1.1101 Detail 101
3/4" = 1'-0"S1.1102 Detail 102
3/4" = 1'-0"S1.1103 Detail 103
3/4" = 1'-0"S1.1104 Detail 104
0102
/6/1
8IS
SUED
FO
R D
EVEL
OPM
ENT
PER
MIT
11 7
/ 8" T
JI J
OIS
TSBY
SU
PPLI
ER11
7/ 8
" TJI
JO
ISTS
BY S
UPP
LIER
11 7
/ 8" T
JI J
OIS
TSBY
SU
PPLI
ER
Eng Beam
Eng Beam
Eng BeamEng Beam
Eng Beam
4' -
4"
Eng Beam
11 7
/ 8" T
JI J
OIS
TS
11 7/8" TJI JOISTS
11 7
/ 8" T
JI J
OIS
TSBY
SU
PPLI
ER
11 7
/ 8" T
JI J
OIS
TSBY
SU
PPLI
ER
Eng Beam
12' - 10" 14' - 0"
8' - 8" 8' - 2" 14' - 10" 6' - 0"
11 7/8" TJI JOISTS
11 7
/ 8" T
JI J
OIS
TS
Eng Beam Eng Beam Eng Beam
3' - 9" 13' - 5 3/4" 8' - 5 1/2"
17' - 6 7/8"
15' -
0"
12' -
6 3
/4"
13' -
9"
202
S2.2
201
S2.2
203
S2.2POINT LOAD ABOVE
200
S2.2 ALL ENG. BEAMS TO BE SUPPLIED& ENGINEERED BY MANUFACTURED WOOD PRODUCTS SUPPLIER TYP.
Eng
Beam
24" ENG. ROOF TRUSSBY SUPPLIER
Eng Beam
8' - 0 7/8" 9' - 0 3/4"11' - 5"
11 7
/ 8" T
JI J
OIS
TSBY
SU
PPLI
ER
38' - 8"
15' -
5 1
/2"
15' -
10
1/2"
4' - 6 1/2"
204
S2.2
14
84
2N
D A
VE
NU
E
V2
L 3
B6
FA
X: 5
63-4
878
TE
L: 5
62
-93
45
PR
INC
E G
EO
RG
E, B
. C
.
DAT
E
ACAD
FIL
ED
WG
NO
.
DR
AWN
BY
PRO
J. N
O.
SCAL
E
CLI
ENT
PRO
JEC
T
DW
G T
ITLE
REV
ISIO
NS
chec
ked
chec
ked
ENG
INEE
R'S
SEA
LD
ATE
ISSU
EDE
NG
INE
ER
ING
CO
NS
UL
TA
NT
S L
TD
.
Con
tract
ors
shal
l ver
ify a
nd b
eres
pons
ible
for a
ll dim
ensio
ns a
nd c
ondi
tions
Writ
ten
dim
ensio
ns s
hall h
ave
prec
eden
ce o
ver s
cale
d di
men
sions
.fo
r cor
rect
ion,
inte
rpre
tatio
n or
revis
ion.
Disc
repa
ncie
s, e
rrors
and
om
issio
ns s
hall b
e re
ferre
d to
the
Con
sulta
ntTh
is dr
awin
g an
d th
e co
pyrig
ht a
re th
e pr
oper
ty o
f the
EN
GIN
EER
.
show
n on
the
draw
ings
. Sho
p dr
awin
gs s
hall b
e su
bmitt
ed to
the
Con
sulta
nt fo
r app
rova
l bef
ore
proc
eedi
ng w
ith fa
bric
atio
n.En
gine
er's
Seal
App
lies
toSt
ruct
ural
Det
ails
Onl
y
NO
.D
ATE
EXPL
ANAT
ION
CO
-DES
IGN
ER
ARC
HIT
ECTU
RAL
DES
IGN
ENG
INEE
RIN
G D
ESIG
N 1
/4" =
1'-0
"
Fram
ing
Plan
sAc
cess
Eng
inee
ring
Con
sulta
nts
Ltd
1714
1
Ow
ner
S2.1
Feb
6, 2
018
S. G
ibso
nBr
uce
John
ston
, P. E
ng.
Che
cker
1/4" = 1'-0"S2.11 Second Floor Framing
1/4" = 1'-0"S2.12 Top Roof Framing
0102
/6/1
8IS
SUED
FO
R D
EVEL
OPM
ENT
PER
MIT
u/s joist 210' - 0 7/8"
Level 211' - 3 1/4"
u/s truss 112' - 0"
1' -
11"
11 7
/8"
1 1/
2"
u/s joist 210' - 0 7/8"
Level 211' - 3 1/4"
u/s truss 112' - 0"
Board Room
Reception
T-BAR CEILING
1' -
11"
1' -
8 3/
4"
8 7/
8"
1' -
0 7/
8"
LVL RIM JOIST
LVL LEDGER
u/s truss 112' - 0"
LVL RIM TYP.ALL FASCIA
I-JOIST BLOCKINGENSURE AIR PATH ABOVE i.e. AS SHOWN
u/s truss 320' - 4 3/8"
1' -
10"
9"
2' - 0"
TRUSS BLOCKING
LVL FASCIA
HARDIE SOFFITSMOOTH/PERFORATEDEXCEPT WITHIN 4'-0" OF PLON WEST SIDEi.e. GARAGE & MECH. ROOM
14
84
2N
D A
VE
NU
E
V2
L 3
B6
FA
X: 5
63-4
878
TE
L: 5
62
-93
45
PR
INC
E G
EO
RG
E, B
. C
.
DAT
E
ACAD
FIL
ED
WG
NO
.
DR
AWN
BY
PRO
J. N
O.
SCAL
E
CLI
ENT
PRO
JEC
T
DW
G T
ITLE
REV
ISIO
NS
chec
ked
chec
ked
ENG
INEE
R'S
SEA
LD
ATE
ISSU
EDE
NG
INE
ER
ING
CO
NS
UL
TA
NT
S L
TD
.
Con
tract
ors
shal
l ver
ify a
nd b
eres
pons
ible
for a
ll dim
ensio
ns a
nd c
ondi
tions
Writ
ten
dim
ensio
ns s
hall h
ave
prec
eden
ce o
ver s
cale
d di
men
sions
.fo
r cor
rect
ion,
inte
rpre
tatio
n or
revis
ion.
Disc
repa
ncie
s, e
rrors
and
om
issio
ns s
hall b
e re
ferre
d to
the
Con
sulta
ntTh
is dr
awin
g an
d th
e co
pyrig
ht a
re th
e pr
oper
ty o
f the
EN
GIN
EER
.
show
n on
the
draw
ings
. Sho
p dr
awin
gs s
hall b
e su
bmitt
ed to
the
Con
sulta
nt fo
r app
rova
l bef
ore
proc
eedi
ng w
ith fa
bric
atio
n.En
gine
er's
Seal
App
lies
toSt
ruct
ural
Det
ails
Onl
y
NO
.D
ATE
EXPL
ANAT
ION
CO
-DES
IGN
ER
ARC
HIT
ECTU
RAL
DES
IGN
ENG
INEE
RIN
G D
ESIG
N 1
" = 1
'-0"
Floo
r & R
oof F
ram
ing
Det
ails
Acce
ss E
ngin
eerin
g C
onsu
ltant
s Lt
d
1714
1
Ow
ner
S2.2
Feb
6, 2
018
S. G
ibso
nBr
uce
John
ston
, P. E
ng.
Che
cker
1" = 1'-0"S2.2203 Detail 203
1" = 1'-0"S2.2201 Detail 201
1" = 1'-0"S2.2202 Detail 202
1" = 1'-0"S2.2200 Detail 200
1" = 1'-0"S2.2204 Detail 204
0102
/6/1
8IS
SUED
FO
R D
EVEL
OPM
ENT
PER
MIT
ByRevisionsDate
Project
Sheet Title
Date
Drawing No.
Scale
Drawn By
Project No.
Copyright reserved. This drawing and the
design are, and at all times remain the
exclusive property of Jay Lazzarin and
cannot be used without the Landscape
Architect's written consent.
1616 8th AvenuePrince George, BC
Landscape Plan
January 31, 2018
1:75
LS
L 1
FEB. 1, 2018 DRAFT FOR REVIEW LS
1484 2ND AVENUE
V2L 3B6FAX: 563-4878
TEL: 562-9345
PRINCE GEORGE, B. C.
ENGINEERING CONSULTANTS LTD.
Sb
Sb
Sb
CBSb
CkCkCk
Ck
CkCkCk
Ck
CkCkCk
Ck
CkCkCk
Ck
CkCk
Ck
Ck
Ck
Ck
Ck
Ck
Ck
CkCkCk
Ck
CkCkCk
CB
CB
CBCB
CBCB
CB
podpod
podpod
pod
pod
pod pod
Ck
Pm
Rp
O
Ppgg
Ppgg
Ppgg
Ppgg
Ppgg
Ppgg
Ms
MsMsMs
O
OO
Pm
Pm
Pm
Pm
Pm
Pm
PmPmPm
Rp
Rp
podpod
pod
PmRp Rp
RpRp
pnpn
pnpn pn
pnpn
pnpn
pn
pn
pn
pn
pnpn
pn
Rp
lc lclc
lc
lclc
kkkk
kk
k
k
kkk
k k
PmPmPmPmPm
Ms Ms Ms
pnpn pn
podpod
pod
pod
pod
pod
Sgf
Sgf
Sgf
SgfSgf
SgfSgf
SgfSgfpn
pnpn
pn
Ck
SgfSgf
SgfSgf
SgfSgf Sgf
Rp
pod
HH
H H HH
H
H HHH
H HHHH
SgfSgfSgf H
HH
H
HHHHH
H
MR
Sr
MR
MR
CB
CB
UP
DN
ENTRANCE
PRO
PER
TY L
INE
108'
-0"
PROPERTY LINE 61'-3"
PRO
PER
TY L
INE
108'
-0"
PROPERTY LINE 61'-3"
VA
NC
OU
VE
R S
TRE
ET
8TH AVENUE
LANE
EX. SIDEWALK
EX
. SID
EW
ALK
TP
EXISTING FENCETO BE REPLACEDWITH NEW FENCE ALONG P.L.
1 6
7 8
9
PEDESTRIAN GATE CO
NC
RE
TE S
IDE
WA
LK
PARKING
OFFSET LINE
FLAT ROOFOVERHANG
PROPOSED BUILDING274.4m2 (2952 sq. ft.)
PARKINGS/C
MAIN ENTRYCONCRETEWALKWAY
COVEREDPATIO
MANHOLESNOW
STORAGE
L.S.
L.S.
L.S.
NEW CITY LIGHTSSEE ELECTRICAL
BIKE RACK(2 SPACES REQ'D)
2 3 4 5
EXISTING ELM TREETREE DIA 600 MMTO BE RETAINED
MAIN ENTRY PORCH,BRUSHED CONCRETE SURFACE
PLANTER FORSEASONAL GARDENING OPPORTUNITES CW600MM DEPTH GROWING MEDIUM. APPROX HEIGHT450MM OFF PATIO / DRAINROCK SURFACE
BOLLARD LIGHT
FLAT ROOFOVERHANG
AE
AE
24" x 24" PRECAST CONCRETE PAVERS
EXISTING ELM TREETREE DIA 750 MMTO BE RETAINED
400 MM
14890MM
To TRE
E C
EN
TER
420 MM
9060 MM
To TRE
E C
EN
TER
N
ENTRANCE
HOOP BIKE RACK BY DERO (OR APPROVED EQUIVALENT)TOTAL ONE (1) - HOLDS 2 BIKESCOLOUR STANDARD BLACK
AE
Property Line / LEED Boundary Line
Brushed Concrete Sidewalk - Refer to Civil Eng. Dwgs.
Proposed 24" x 24" Precast Concrete Pavers on Prepared Subbase
Planting Beds cw 70 mm Bark Mulch on Filter Fabric on Approved Growing Medium At Specified Depths(450 mm minimum For Shurbs & 750 mm minimum For Trees)
Lawn Areas Within ROW cw 150 mm Min of Approved Growing MediumOver Prepared Subgrade.
100 MM Depth, 3/4" - 2" Decorative Rock Groundcover onFilter Fabric Liner cw 2" x 6" Pressure Treated Wood Edger
1/8th x 4" Aluminum Edger (Lawn / Planting Seperation)
Proposed New 6' Wood Fence For Privacy Screening- Refer to Arch. Dwgs. For Details
Bollard - With Full Cut Off & Directional Lighting DSC ( 1 Total )
Catch Basin - Refer to Civil Engineers Drawings
Telephone Pole - Existing
Existing Mature Trees (2 Total) - To Be RetainedUlmus pumila - Siberian ElmSizes & Locations As Indicated On Drawing
CS
TP
ALL WORK AND MATERIALS SHALL BE TO BCSLA, CNLA STANDARDS
LEGENDDARK SKY COMPLIANT BOLLARD LIGHTSELUX INULA OR EQUIVALENT TOTAL ONE (1)COLOUR BLACK
1.8 METER HIGH WOOD PRIVACY FENCE - SIMILAR TO ABOVENATURAL WOOD STAIN TO COMPLEMENT BUILDING
PLANT LISTSYMBOL BOTANICAL NAME COMMON NAME COUNT SIZE
TreesMaR Malus x adstringens 'Spring Snow' 'Spring Snow' Flowering Crab Apple 3 6cm Cal. Typ.Sr Syringa reticulata Japanese Lilac Tree 1 6cm Cal. Typ.
Shrubs Ms Philadelphus x Galahad Galahad Mock Orange 7 #2 potpod Physocarpus opulifolius 'Donna May' Little Devil Ninebark 18 #2 potPm Pinus mugo pumilio Dwarf Mugo Pine 16 #5pot
Ppgg Picea pungens 'Glauca Globosa' Dwarf Globe Blue Spruce 6 #5potRp Rosa acicularis Prickly Rose 9 #2 potSgf Spiraea x bumalda Goldflame Spirea 19 #2 potSb Symphoricarpos albus Snowberry 4 #2 pot
Groundcovers / Grasses / Perennials / Fernsk Arctostaphyllos uva-ursi Kinnickinnick 13 #1pot
Ck Calamagrostis x acutiflora 'Karl Foerster' Feather Reed Grass 34 #1potH Helictotrichon sempervirens Blue Oat Grass 26 #1pot
Hpp Heuchera micrantha Purple Leaved Coral Bells 8 #1potlc Lilium lancifolium Tiger Lily 6 #1potO Matteuccia struthiopteris Ostrich Fern 4 #1potpn Potentilla tridentata 'Nuuk' Nuuk Cinquefoil 23 #1pot
FEB. 5, 2018 ISSUED FOR DEVELOPMENT PERMIT LS