PG-Flex micro-DLC System
Upload
others
View
6
Download
0
Embed Size (px)
344 x 292
429 x 357
514 x 422
599 x 487
Citation preview
PG Flex Subscriber Carrier System.qxdmicro-DLC System
ADC's PG-Flex micro-DLC provides feeder (F1), distribution (F2) or
drop "pair relief" in areas of the network suffering from copper
pair shortages. It enables Local Exchange Carriers (LECs) to
quickly and cost-effective- ly meet held order demands for POTS or
ISDN services in these areas. PG-Flex is a far superior alternative
to expensive and time consuming alternatives of cable rearrange-
ments, laying more cable or installing a large capacity Digital
Loop Carrier (DLC) system.
The PG-Flex micro-DLC is a highly versatile platform supporting
both indoor and out- door pair relief applications. Remote termi-
nals (RTs), which are deployed in 24-channel increments, are
available in 24, 48 and 96- channel configurations. Outside plant
hard- ened enclosures include 24/48-channel ver- sions with
complete lightning protection for installation at crossboxes or
existing
DLC/SLC cabinets. Indoor RTs, available in 24/48/96-channel
versions, provide a cost- effective alternative to standard D4
channel banks. All PG-Flex remotes are line-powered reducing the
need for costly batteries and UPS systems.
Features:
• Traditional HDSL transmission architecture • 24-channel system
architecture • Extended temperature rating • Supports POTS and ISDN
services • Supports MLT testing (TR-909) • Indoor and outdoor
specific remotes • TR-57 (VF) switch interface • Supports
crisis/temporary service needs
1 /
0 0
0 4
0 P
R PG
-F le
x Su
b sc
ri b
er C
ar ri
er S
ys te
m Application
w w w . a d c . c o m • + 1 - 9 5 2 - 9 3 8 - 8 0 8 0 2
Figure 1. Basic PG-Flex Configuration
CO Residential or Business Customers
Crossbox PG-Flex RT
CO
Business
1 /
0 0
0 4
0 P
R PG
-F le
x Su
b sc
ri b
er C
ar ri
er S
ys te
m Description
w w w . a d c . c o m • + 1 - 9 5 2 - 9 3 8 - 8 0 8 0 3
General Specifications COT and RT equipment are designed to operate
over an extended temperature range. RTs meet the environmental
conditions found in the outside plant. The following specifications
apply to all PG-Flex hardware:
Temperature: -40º to +65º C (-40º to +150º F) Relative Humidity: 5%
to 95% (non-condensing) Altitude: -200 to 13,000 ft (-60 to 4,000
m)
COT Equipment Specifications COT Shelves Dimensions (HxWxD):
FCS-718: 8.75 x 19.0 x 11.75 in (22.2 x 48.3 x 29.9 cm)
FCS-719: 8.75 x 23.0 x 11.75 in (22.2 x 58.4 x 29.9 cm) Weight:
FCS-718: 15.5 lbs (7.0 kg) FCS-719: 20.2 lbs (9.2 kg) Mounting: EIA
hole spacing on universal mounting flanges Finish: zinc plated and
aluminum irridited Terminations: Subscriber Lines: 25-pair Amphenol
or wire wrap
HDSL Lines: wire wrap Alarm Relays: wire wrap CO Battery: screw
terminal Metallic Bypass: wire wrap PGTC Interface: 25-pair
Amphenol
System Power Input Voltage: Fused -42 to -56 VDC Requirements Input
Power: 145 watts (maximum)
Line Output Voltage: ±130 VDC (maximum) Line Output Power: 100
watts (maximum)
POTS Channel Interface Analog Impedance: 900 (FLC-703 L4) DC
Off-Hook Resistance: 960
Ringer Equivalence: 0.9 REN at 20 Hz Ring Detection at COT: 65 to
104 Vrms @20 to 60 Hz, superimposed on a DC component of -36 to -56
VDC
ISDN Channel Interface “U” Interface: per ANSI T1.601-1992
RT Equipment Specifications Ring Output Voltage (At Station):
>40 Vrms AC at full load Generator Output Voltage DC Pedestal:
-75 VDC to -40 VDC
Frequency: 20, 25, 30 Hz (±1 Hz) (programmable at system setup and
fixed for the entire system) Crest Factor: 1.2 to 1.6 Output Load:
15 REN maximum per system
RT Power Input Voltage: ±130 VDC to ±70 VDC Supply Input Power:
<40 watts
POTS Analog Impedance: 600 DC Loop Current: >23 mA into off-hook
DC resistance Ringer Output Drive: 5 REN maximum per port RT DC
Supervisory Range: 960 (Max. cable loop resistance, minus 430 for
handset, is 530 ) RT Idle State Loop Voltage (On-Hook): >40 VDC
(Note: ring is negative with respect to Tip) RT Loop Closure
Detection (Off-Hook): RT recognizes resistance between tip and ring
960 as loop closure RT On-Hook Detection: The RT recognizes a
resistance 10 k as an on-hook condition
ISDN “U” Interface: per ANSI T1.601-1992
Wire Gauge
26 AWG 0.4 mm 24 AWG 0.5 mm 22 AWG 0.6 mm 19 AWG 0.9 mm
PG-Flex Distance Table
9.0 kft 2.7 km
12.3 kft 3.7 km 16.1 kft 4.9 km 22.8 kft 7.0 km
Subscriber Drop
6.3 kft 1.9 km
10.2 kft 3.1 km 16.3 kft 4.9 km 29.4 kft 7.5 km
Web Site: www.adc.com From North America, Call Toll Free:
1-800-366-3891 • Outside of North America: +1-952-938-8080 Fax:
+1-952-946-3292 For a complete listing of ADC's global sales office
locations, please refer to our web site.
ADC Telecommunications, Inc., P.O. Box 1101, Minneapolis, Minnesota
USA 55440-1101 Specifications published here are current as of the
date of publication of this document. Because we are continuously
improving our products, ADC reserves the right to change
specifications without prior notice. At any time, you may verify
product specifications by contacting our headquarters office in
Minneapolis. ADC Telecommunications, Inc. views its patent
portfolio as an important corporate asset and vigorously enforces
its patents. Products or features contained herein may be covered
by one or more U.S. or foreign patents.
100040PR 1/02 Revised ©2002 ADC Telecommunications, Inc. All Rights
Reserved An Equal Opportunity Employer
RT Equipment Catalog Number Description Line Units FRL-742 L3C
24-channel RTLU (POTS, LS/GS, ISDN, PGTC) Channel Units FRC-753 L4C
8-channel LS/GS RTCU (µ-Law, PGTC)
FRC-756 L1A 4-channel ISDN RTCU (PGTC)
FRE-765 FRE-860 FRE-865 FRE-867 FRE-868 FRE-869 Remote Terminals
L4A L1 L1 L1B L1 L1B L1 L2 L3 L4 L1 L2 Mounting: Indoor • • • • •
•
Outdoor • • • • • • Wall • • • • • • • • • • Pole • • • • •
Pedestal • Rack •
Subscriber 24 (1 System) • • • • • • Lines: 48 (2 Systems) • • •
•
96 (4 Systems) • • Subscriber 35’ Gel-filled Stub • • Terminations
35’ Non-filled Stub • •
Amphenol (male) • • • • • • Gel-filled IDC • Marconi A-Line •
HDSL, Bypass, 35’ Gel-filled Stub • • Auxiliary Power 35’
Non-filled Stub • • Terminations Amphenol (male) • •
Marconi A-Line • AMP Quiet Front • Screw Terminal • • • •
Subscriber 5-Pin Sockets • • • • • Protection Included in IDC
•
None • • • • • • HDSL, Bypass, 5-Pin Sockets • • • • • • •
Auxiliary Power AMP Quiet Front • Protection None • • • •
Dimensions Height (in/cm) 19.25/48.9 23.6/59.9 23.6/59.9 23.6/59.9
23.6/60.2 23.6/60.2 22.7/57.8 22.7/57.6 22.7/57.8 22.7/57.6
22.7/57.7 22.7/57.7
Width (in/cm) 14.25/36.2 8.7/22.1 8.7/22.1 8.7/22.1 17.25/43.7
17.25/43.7 11.3/28.6 6.0/15.2 11.3/28.6 6.0/15.2 23.0/58.4
23.0/58.4 Depth (in/cm) 5.93/15.0 6.8/17.3 6.8/17.2 6.8/17.2
6.8/17.2 6.8/17.2 7.25/18.4 7.25/18.4 7.27/18.4 7.25/18.4 7.25/18.4
7.25/18.4
Weight Pounds 26.3 30.0 34.0 34.0 56.0 56.0 25.0 15.0 25.0 15.0
46.0 46.0 Kilograms 11.9 13.6 15.4 15.4 25.4 25.4 11.3 6.8 11.3 6.8
20.9 20.9
R T C o n f i g u r a t i o n s
COT Equipment Catalog Number Description Common Equipment FCS-718
L2B 19" COT shelf (wire wrap, split power, heat deflector)
FCS-718 L4B 19" COT shelf (amphenol, split power, heat deflector)
FCS-719 L2B 23" COT shelf (wire wrap, split power, heat deflector)
FCS-719 L4B 23" COT shelf (amphenol, split power, heat deflector)
FAU-728 L1B alarm unit FAU-728 L2 alarm unit (composite clock)
FPI-729 L1 PGTC interface unit (composite clock)
Line Units FLL-712 L3C 24-channel COLU (POTS, LS/GS, ISDN, PGTC)
Channel Units FLC-703 L4B 8-channel LS/GS COCU (µ-Law, PGTC)
FLC-706 L1A 4-channel ISDN COCU (PGTC) Doublers HDU-404 L2
24-channel doubler
HDU-407 L2 24-channel doubler HDU-409 L2 24-channel doubler
O r d e r i n g I n f o r m a t i o n