12
PERSEUS USER TEST Joerg Klingenfuss updated 5 March 2014 Klingenfuss Radio Monitoring www.klingenfuss.org A radio monitoring service "in a neighbouring country" - they say so in Malaysia whenever they mean Indonesia, and everybody knows it - recently asked us to test the Software Defined Receiver Perseus manufactured by Microtelecom from Italy. The set did run "along" beside the continuous reception and decoding of utility radio stations with  professional equipment. The receiver, i.e. the hardware, is very good. The software is così-così. Overall: good! There is a 1,600 kHz wide FFT/sonagram window, and a smaller window for the filters. The FFT/sonagram window allows a good overall view on "neighbouring signals" and has been used precisely for that: to check what else is around, and tune interesting signals afterwards on a  professional receiver (it takes way too long to do that on the Perseus) and continue the standard  procedure with WAVECOM. Playing around patiently in the filter window gives pretty nice results. For once, a strong signal  just outside of the filter passband does not influence the sensit ivity of the receiver. Well done. The Graphical User Interface is easy to operate if you have compiled - with great difficulty! -, wrote down and studied intensively the numerous - and in some cases unusual - abbreviations and functions (see Appendix) that show up on all those controls, and are far from being completely described in all those instruction manuals. Fa da ridere. Inoltre, as with any reasonable handbook from the Cheap Chinese Hinterland, we expect a nice graphic overview of the complete GUI with clear definitions of all controls, i.e. exactly that what we used to call explosive drawing. Comunque ... non c'è! Poi, c'è il caso del software. And here is the big problem. There are no scanning functions at all, that come already with all those cheap little radios of today, and the direct frequency input - i.e. the most important and most frequent (sic) setting at all! - is a bad joke from the ergonomic Stone Age, and in a "new" software version is even worse than before. Believe it or not, but you have to 1 double-click on the frequency 2 click again in the input window 3 enter the frequency on the keyboard, or click on numeric keys 4 click MHz or kHz 5 close the frequency window. Mai visto una roba pazza del genere. Fa davvero scuotere la testa, 'starobalì d'oltroalpe. Roba da matt'!

persuser.pdf

  • Upload
    fer-gu

  • View
    9

  • Download
    0

Embed Size (px)

Citation preview

  • 5/21/2018 persuser.pdf

    1/12

    PERSEUS USER TEST

    Joerg Klingenfuss updated 5 March 2014

    Klingenfuss Radio Monitoring

    www.klingenfuss.org

    A radio monitoring service "in a neighbouring country" - they say so in Malaysia whenever they

    mean Indonesia, and everybody knows it - recently asked us to test the Software Defined

    Receiver Perseus manufactured by Microtelecom from Italy.

    The set did run "along" beside the continuous reception and decoding of utility radio stations with

    professional equipment.

    The receiver, i.e. the hardware, is very good. The software is cos-cos. Overall: good!

    There is a 1,600 kHz wide FFT/sonagram window, and a smaller window for the filters.

    The FFT/sonagram window allows a good overall view on "neighbouring signals" and has been

    used precisely for that: to check what else is around, and tune interesting signals afterwards on a

    professional receiver (it takes way too long to do that on the Perseus) and continue the standard

    procedure with WAVECOM.

    Playing around patiently in the filter window gives pretty nice results. For once, a strong signaljust outside of the filter passband does not influence the sensitivity of the receiver. Well done.

    The Graphical User Interface is easy to operate if you have compiled - with great difficulty! -,

    wrote down and studied intensively the numerous - and in some cases unusual - abbreviations and

    functions (see Appendix) that show up on all those controls, and are far from being completely

    described in all those instruction manuals. Fa da ridere. Inoltre, as with any reasonable handbook

    from the Cheap Chinese Hinterland, we expect a nice graphic overview of the complete GUI with

    clear definitions of all controls, i.e. exactly that what we used to call explosive drawing.

    Comunque ... non c'!

    Poi, c' il caso del software. And here is the big problem. There are no scanning functions at all,

    that come already with all those cheap little radios of today, and the direct frequency input - i.e.

    the most important and most frequent (sic) setting at all! - is a bad joke from the ergonomic Stone

    Age, and in a "new" software version is even worse than before. Believe it or not, but you have to

    1 double-click on the frequency2 click again in the input window3 enter the frequency on the keyboard, or click on numeric keys4 click MHz or kHz5

    close the frequency window.

    Mai visto una roba pazza del genere. Fa davvero scuotere la testa, 'starobal d'oltroalpe.

    Roba da matt'!

  • 5/21/2018 persuser.pdf

    2/12

    NOI INVECE DESIDERUMMA:

    SPACE BAR

    12345

    ENTER

    and the receiver is tuned to the frequency 12345, without any more fuss, and that was that.How else? Porco cane!

    What's more, this product is yet another proof that the poor radio amateurs don't have the faintest

    idea of professional utility radio stations. There is no 0.5 kHz or 3 kHz, let alone free definable,

    channel spacing, but only 5 and 9 kHz for the rapidly dying out "BCLs". Equally useless is the

    limit on 499 Hz in the database window. What we need is a reasonable value that can be freely

    set by the user, per esempio 3 or 10 kHz.

    Starobal realizzata, the set would be quite suitable for the reception of utility radio stations ...

  • 5/21/2018 persuser.pdf

    3/12

    Hundreds of fascinating screenshots of Perseus - and superb WAVECOM Digital Data Decoders

    such as W-CODE W61PC W51PC - can be found on our website www.klingenfuss.org .

    More than 9,400 (nine thousand four hundred!) screenshots are published on our brandnew

    DIGITAL DATA DECODER SCREENSHOTS ON USB STICK!

    Another note on the hardware. Ragazzi, the attached power supply by Friwo or the like at a cost

    of four Mickey Mouse Dollars (see Internet) or the like is a real disaster, vuol dire a perfect

    sawtooth generator. We just can't understand that such bad equipment is thrown into the cardboxof such a sensitive shortwave receiver. See also several bloody vicious comments on the Internet,

    per example by the long-term receiver test guru of Passport on http://n9ewo.angelfire.com/

    perseus.html.

    PS "See what you hear " might be an alleged and incredible sensation for "DXers", for the

    decoding of digital utility radio stations however it has been our standard procedure for decades

    and, ragazzi, really is not worth mentioning. More than 30 years ago - our invention! - we used

    high-tuned fast-running mechanical fax machines for the perfect analysis of all types of unknown

    data transmissions. The last time we explained this technique in the RADIOTELETYPE CODE

    MANUAL- today's RADIO DATA CODE MANUAL- 10thedition 1987 page 60. Only afterthat, WAVECOM - who else - got the idea to implement this as "Bit Correlation Analysis" ...

  • 5/21/2018 persuser.pdf

    4/12

    Yet another note on the GUI itself: several parameters are nearly unreadable; that is drastically

    inconsiderate against the user. Colour selection and typeface size are simply disastrous.Passport

    2009says on page 147 "dark with smallish typeface, several GUI icons are hardly legible", and

    that goes particularly for the most important parameter at all, i.e. the frequency, what else, porco

    cane! How about readable and reasonable icons and colours and contrasts?! A "new" software

    version of December 2009 provided, again, totally useless colour pallette gimmicks and the like

    in the sonagram, while leaving the dreadful GUI unchanged at the same time!

    Many users think and say the same and contacted us nel frattempo. For example, DG2HAWsaw

    the unique Perseus utility station reception screenshots on our webpage and asked on 18 Novem-

    ber 2009: "I've seen the modified software interface of the Perseus on your website. It looks

    really great. I would like to ask if I can realize the same modification on my Perseus?? If so, can

    you give me some advice?" Hans-Jrgen Kariuswrote on 3 December 2009: "Where can I get

    the beautiful white GUI for the Perseus, that you use to illustrate the Perseus database?

    It is decidedly clearly arranged."

    Answer: "That WOULD be nice, but it is not available. Already one year ago we proposed

    several suggestions for improvement to that Mister Nico - io parlo perfettamente Valsesianoperch sono ... - but he did not even answer our e-mails and letters. Only if even more customers

    complain about the unergonomic colours and the idiotic frequency control, there could finally

    happen something. Let's go!"

  • 5/21/2018 persuser.pdf

    5/12

    Appendix: Functions

    The amateurish "instruction manuals" of both the manufacturer and the German distri-

    butor SSB are tutte e due incomplete and, consequently, unprofessional! Larry van Horn

    N5FPW gets the same impression inMonitoring TimesSeptember 2009: "The instruction manual

    itself isnt among the best. A lot of the monitoring capability of this SDR isnt discussed adequa-

    tely or at all." Says John Collins on 24 February 2010: "The documentation might as well not beincluded. I discovered more from the quick-tips in your review than I can find anywhere in the

    original documentation." Says Gene Fender KE5JPP on www.eham.net: "There are some buttons

    that do not work with no explanation in the manual. The manufacturer Microtelecom has a histo-

    ry of treating customers like enemies on the Perseus Yahoo support group when you make any

    criticisms of the Perseus." Says Chris Black N1CP on 29 November 2010: "My repeated commu-

    nications concerning bugs have gone unanswered. I am not qualified nor do I want to become

    qualified to have to overlay some nimrad software with the product I purchased in order to have it

    perform as originally advertised." Ecco, ragazzi: il discorso questo. Te cap?! Che vergogna!

    On the two graphics on page 52, an expert can easily see the disastrous sawtooth generator calledcheap power supply. Che vergogna that not even the dealer SSB uses something professional ...

    Click on the Perseus icon upper left, makes all software parameters accessible via Settings. Set

    Reverse Mouse Wheel to 1, RTTY Tone Pitch to 1700 Hz instead of 1360 Hz. This gives a

    correct display of digital data station's frequencies in our frequency list, using the RTTY mode

    with the standard decoding offset of 1700 Hz.

    CF Step defines the step in the main window with arrows .

    In the main window, running the FFT spectrum makes arrows set the amplitude in the

    same way like Ref Lev and Scale on the left side. This is not possible with the sonagram.

    What all those amateurs out there call a "waterfall" is in reality a perfect sonagram.

    See the precise definition in the ITU Spectrum Monitoring Handbook!

    AVG Main controls the averaging in the main window. AVG Sec does the same in the filter

    window.

    Dither should be used only for measurements, in any case don't use it with very low noise levels.

    Preamp is a preamplifier, gives just 2-3 dB and makes sense only above 20 MHz.

    For DRM AGC on Slow; bandwidth to 25 kHz, close filter window to around 11-12 kHz.

    Center activated, clicking on a signal in the main window tunes this frequency with the

    parameters used in the filter window, and the frequency range in the main window sets to the new

    frequency in the center. Center disactivated, clicking on a signal in the main window does the

    same without setting the frequency range to the new center. The description of that feature in the

    instruction manual is totally useless.

    ZOOM in the filter window zooms the main window, set values with the arrows of Span (kHz).

    Using the notch filter, the mouse wheel adjusts the filter width.

    NB Lev is noise blanker inversed: high threshold below, low threshold on the top ...

    NBW is Noise Blanker Wide, NBN is Narrow.

  • 5/21/2018 persuser.pdf

    6/12

    SpkRej is Spike Rejection against pulse interference, use only with CW and SSB, avoid with

    digital data.

    NR is Noise Reduction, do not use with digital data.

    For digital data set AGC always to Fast, only for DRM and complex STANAG aggregates set to

    Med or Slow.

    ADC Clip is Analog Digital Converter Clip control, ATT adds 10 20 30 dB.

    For Squelch tuning, click below S 9. Right mouse key switches off.

    For Mute tuning, click above S 9. Right mouse key switches off.

    Click on WFall in the sonagram mode changes the running direction su e gi.

    Activate Labels, gives frequency and signal strength parameters in the main window. Activate

    PeakSrc, tunes to the nearest signal peak.

    BANK in the MEM window makes up to 6 frequency databases with up to 100 entries each.

    ALL in the MEM window shows all entries of a database (not of alldatabases!) independently

    from the time. "Active" stations are displayed in yellow. Strangely enough, scrolling the frequen-

    cy list runs vice versa, i.e. the first entry for each frequency is on the bottom and the last one on

    the top. It makes more sense to use our SUPER FREQUENCY LIST ON CDthat has been pre-

    sorted perfectly ergonomic - for decades!

    The USER demodulator (on the right side of DRM) can be used for VAC and W-CODE.

    VAC Control Panel, Cable Parameters to SR 62500 ... 192500.

  • 5/21/2018 persuser.pdf

    7/12

    VAC Control Panel, Cable Parameters for SIGMIRAhave not been changed. SIGMIRA does

    a good job decoding STANAG 4285, however it is a quite stubborn program, like principally all

    those "solutions" from and for the amateur market, and per questo unacceptable for professional

    users. Install and de-install several times to get it running.

    VAC Control Panel, Cable Parameters for DRMto SR 62500 ... 62500. Different settings seem

    to work as well, check on the Internet.

    This setting, however, is unstable and results in phase jumps with weatherfax reception. Cable

    Parameters for Wetterfax have to be set to 22050 - 192000, see the WAVECOM website.We also use 22050 - 96000. If this constellation does not help - since PERSEUS and W-CODE

    excessively use slow PC's computing power! -, simply try smaller Sampling Rates on the Perseus.

  • 5/21/2018 persuser.pdf

    8/12

    For the modification of the settings for e.g. SIGMIRA and DRM, or weatherfax, exit not only

    W-CODE and Perseus, but also the WAVECOM Server!

  • 5/21/2018 persuser.pdf

    9/12

    Klingenfuss Radio Monitoring has been testing and optimizing the brandnewPLATH go2monitorand go2signalsdigital data decoders since their introductiononly in 2013. These easily connect to SDRs such as the PERSEUS and display upto 1,600 kHz bandwidth in their sonagram and/or FFT. The sophisticated softwareruns up to 64 (!) classification / recognition / decoding / recording channels overthat wide frequency range by simply clicking on a selected signal!

  • 5/21/2018 persuser.pdf

    10/12

    8454.8 kHz STANAG 4285 + 8434.0 kHz CW 4250.5 kHz PACTOR-2 11384.0 kHz ACARS

  • 5/21/2018 persuser.pdf

    11/12

    2014 FREQUENCY DATABASE

    FOR THE PERSEUS LF-MF-HF

    SOFTWARE-DEFINED RECEIVER

    We again offer an updated and ready-to-use specially formatted individual frequency list

    USERLIST.TXT. Our latest 2014 data comprises more than 13'500 entries and includes

    thousands of fascinating digital data stations on HF. This is the only database that includ-

    es both broadcast and utility radio stations worldwide. See the contents in the MEM field

    of the sample screenshots below and overleaf!

    For even more superb screenshots click "Perseus Database" on our website. An 8-pages

    critical field test of the MICROTELECOM Perseus SDR, referring particularly to thereception of digital utility radio stations, can be found on our website as well.

    The frequency 8424 kHz gives you 5 entries. The waterfall display here is 100 kHz wide and shows in

    full detail, from left to right:

    ellipse: the single letters of the Morse code identification IAR and the SITOR call burst on 8418 kHz ellipse: the single letters of the Morse code identification SVO and the SITOR call burst on 8424 kHz ellipse: SITOR call burst of station TAH on 8431 kHz weak, not marked: SITOR call burst of station UAT on 8431.5 kHz ellipse: the single letters of the Morse code identification TAH (clearly not in parallel to 8431 kHz!)

    and the SITOR call burst on 8434 kHz circle: teleprinter emission of station PBB on 8439 kHz circle: PSK aggregate signal of station FUG on 8454.8 kHz circle: PSK aggregate signal of station RETJ on 8465 kHz

  • 5/21/2018 persuser.pdf

    12/12