Performance Testing of Vertical Turbine Pumps for Power Plant Applications

Embed Size (px)

Citation preview

  • 8/11/2019 Performance Testing of Vertical Turbine Pumps for Power Plant Applications

    1/20

    Xylem Water Solutions (India) Pvt. Ltd.

    PERFORMANCE TESTING OF VERTICAL TURBINE PUMPSFOR

    POWER PLANT APPLICATIONS

    Ron SassoonCell : + 91 7738083550

    Email : [email protected] April 2012

  • 8/11/2019 Performance Testing of Vertical Turbine Pumps for Power Plant Applications

    2/20

    Xylem Water Solutions (India) Pvt. Ltd.,

    Transformation (November 2011) -

    The name Xylem is derived from classical Greek and is the tissue that transports water inplants, highlighting the engineering efficiency of our water-centric business by linking it withthe best water transportation of all that which occurs in nature

    Xylem is a premier pure-play water technology company

    A singular focus on innovative solutions serving global water marketsHeadquartered in White Plains, N.Y12,000 employees worldwidePresence in more than 150 countries

    2011 revenues of $ 3.8 billionMore than a century of experience in the water industry

    Xylem [XYL] will be a leading global water technology provider, enabling customers totransport, treat, test and efficiently use water in public utility, residential and commercialbuilding services, industrial and agricultural settings.

    2

  • 8/11/2019 Performance Testing of Vertical Turbine Pumps for Power Plant Applications

    3/20

    Xylem Water Solutions (India) Pvt. Ltd.,

    Present scenario : -

    3

  • 8/11/2019 Performance Testing of Vertical Turbine Pumps for Power Plant Applications

    4/20

    Xylem Water Solutions (India) Pvt. Ltd.,

    Need for change : -

    1. Critical analysis of existing performance qualification methods.

    2. Acceptance of pumps > 90% Efficiency.

    3. Evaluate performance measurement with direct measurements.

    4

  • 8/11/2019 Performance Testing of Vertical Turbine Pumps for Power Plant Applications

    5/20

    Xylem Water Solutions (India) Pvt. Ltd.,

    Leap forward for high efficiency system: -

    5

  • 8/11/2019 Performance Testing of Vertical Turbine Pumps for Power Plant Applications

    6/20

    Xylem Water Solutions (India) Pvt. Ltd.,

    Testing pump for 90 % & above : -

    6

  • 8/11/2019 Performance Testing of Vertical Turbine Pumps for Power Plant Applications

    7/20

    Xylem Water Solutions (India) Pvt. Ltd.,

    Testing pump for 90 % & above ( Multispeed ) : -

    7

  • 8/11/2019 Performance Testing of Vertical Turbine Pumps for Power Plant Applications

    8/20

    Xylem Water Solutions (India) Pvt. Ltd.,

    Impact of efficiency on the pump operating cost : -

    Case I Case II

    Plant capacity 2 x 660 MW 2 x 660 MW

    Pump application Circulating cooling water

    Number of pumps 2 x 50 % ( 4 nos ) 2 x 50 % ( 4 nos )

    Cooling Water required per unit 90,000 Cu.m / Hr 90,000 Cu.m / Hr

    Pump capacity @ head 45,000 Cu.m / Hr @ 25 MWC 45,000 Cu.m / Hr @ 25 MWC

    Pump efficiency 88 % 90 %

    Duty point pump input power 3481.51 KW per pump 3404.14 KW per pump

    Motor rating @ 15 % Margin 4004 KW per pump 3915 KW per pump

    Total duty point power ( 4 pumps

    )

    13,926.02 KW 13,616.56 KW

    Difference in duty point power 309.46 KW

    8

    Cost of operating a low efficiency circulating cooling water pumps ???

  • 8/11/2019 Performance Testing of Vertical Turbine Pumps for Power Plant Applications

    9/20

    Xylem Water Solutions (India) Pvt. Ltd.,

    Pump testing : -

    9

    TRADITIONAL 2 WATT METER TESTINGWITH JOB MOTOR

  • 8/11/2019 Performance Testing of Vertical Turbine Pumps for Power Plant Applications

    10/20

    Xylem Water Solutions (India) Pvt. Ltd.,

    Shortfalls in normal Performance testing method : -

    1. Full column pipe length.

    2. Calibrated job motor.

    3. Full speed.

    4. Indirect way of shaft power measurement.

    5. Manual recording of reading # No data log.

    6. Lack of verification of motor efficiency at full & part load.

    7. Unavailability of performance at variable speed.

    8. All the above results in shaft power measurement errors & inefficiencies.

    10

  • 8/11/2019 Performance Testing of Vertical Turbine Pumps for Power Plant Applications

    11/20

    Xylem Water Solutions (India) Pvt. Ltd.,

    Suggested Performance testing method : -

    11

    1. SUPPLY WITH HIGH VOLTAGE VFD FOR 50/ 60 HZ CONSTANT

    2. FREQUENCY IRRESPECTIVE OF VARATION OF GRID FREQUENCY

    VARIATION

    3. STEPLESS OUT PUT VOLTAGE SELECTABLE FORM 3.3 KV TO 11 KV.

    4. TORQUE TRANSDUCER BETWEEN PUMP AND MOTOR FOR ACCURATESHAFT POWER MEASUREMENT.

    5. DATA ACQUISITION SYSTEM TO ELEMENT MANUAL READING.

    6. ACCURATE MEASUREMENT OF PUMP AND MOTOR POWER ANDEFFICIENCY.

    7. NO CALIBRATED MOTOR IS REQUIRED.

    8. PUMP TESTING WITH FULL COLOUMN LENGTH AND FULL SPEED.

    9. PUMP AND MOTOR POWER MEASUREMENT AT MULTI SPEED OPERATION.

  • 8/11/2019 Performance Testing of Vertical Turbine Pumps for Power Plant Applications

    12/20

  • 8/11/2019 Performance Testing of Vertical Turbine Pumps for Power Plant Applications

    13/20

    Xylem Water Solutions (India) Pvt. Ltd.,

    Key features of the proposed system : -

    13

    1. Supply with high voltage VFD offering 50/ 60 HZ constant.

    2. Stable frequency irrespective of variation of the grid frequency variation.

    3. Step less output voltage selectable from 3.3 KV to 11 KV.

    4. Torque transducer between pump & motor gives accurate shaft power readings.

    5. Automated data acquisition system eliminates requirement of manual readings.

    6. Accurate measurement of pump & motor power & efficiency.

    7. Calibrated motor not required.

    8. Pump to be tested with full column suspension length & at full speed.

    9. Pump & motor power measurements can be had at multi speed operation.

  • 8/11/2019 Performance Testing of Vertical Turbine Pumps for Power Plant Applications

    14/20

    Xylem Water Solutions (India) Pvt. Ltd.,

    Schematic diagram of the proposed system : -

    14

  • 8/11/2019 Performance Testing of Vertical Turbine Pumps for Power Plant Applications

    15/20

    Xylem Water Solutions (India) Pvt. Ltd.,

    Test facility specifications : -

    15

    1. Wet pit 45 mts x 7.9 mts x 10 mts deep for testing vertical turbine pumps.

    2. Dry pit 25 mts x 8 mts x 7 mts deep for testing horizontal split case pumps &

    metallic volute pumps.

    3. Overhead crane capacity 90 T & 40 T.

    4. Variable frequency drive for testing of pumps at 50 Hz & 60Hz frequency.

    5. Supply capacity up-to 7.3 MW.

    6. Flow measuring capacity of up-to 1,20,000 m^3/hr

  • 8/11/2019 Performance Testing of Vertical Turbine Pumps for Power Plant Applications

    16/20

    Xylem Water Solutions (India) Pvt. Ltd.,

    Test facility instrumentation : -

    16

    1. Details of measuring instruments :

    2. Output of all the instruments integrated thru DAS in control room.

    3. No human intervention during testing process to eliminate any errors.

  • 8/11/2019 Performance Testing of Vertical Turbine Pumps for Power Plant Applications

    17/20

    Xylem Water Solutions (India) Pvt. Ltd.,

    Select reference of high efficiency pumps : -

    17

    Sr.

    No.

    Client Year of

    supply

    Qty Model Type Discharge

    Cu.M/Hr

    Head

    M

    Speed

    RPM

    Motor

    HP

    1 Yanpet, Saudi Arabia 1998 1 132 x 96 WCBRVerticalColumn

    60,046 20 212 5360

    2

    Korea Hydro & Nuclear

    Power - Shin Kori Units 1 & 2 2003 8 100 x 84 WCA

    Vertical

    Column

    44,324

    15 293 3200

    3Southern Power Station,Israel

    1982 4 108 x 78 WCARVerticalColumn

    41,328 15 330 3000

    4 We Energies - Elm Road 2007 4 96 WCAXVerticalColumn

    46,597 5.9 225 1750

    5 Amergen - Clinton 2008 1 114 x 84 WMCCVerticalColumn

    43,089 29.8 320 5500

  • 8/11/2019 Performance Testing of Vertical Turbine Pumps for Power Plant Applications

    18/20

    Xylem Water Solutions (India) Pvt. Ltd.,

    18

    This is not special for us.

  • 8/11/2019 Performance Testing of Vertical Turbine Pumps for Power Plant Applications

    19/20

    Xylem Water Solutions (India) Pvt. Ltd.,

    Registered Office & Factory : Plot no. 731, GICD Savli, Manjusar, Savli Road,

    Vadodara 391 770

    Telephone : +91-2667-265 700

    Fax : +91-2667-265 764

    Corporate office : Ground & First Floor, Vishnu Shivam Mall,

    Thakur Village, Kandivali (East),

    Mumbai 400 101

    Telephone : + 91 22 40 370 370

    Web : www.xyleminc.com / www.xylemindia.in

    19

  • 8/11/2019 Performance Testing of Vertical Turbine Pumps for Power Plant Applications

    20/20

    Xylem Water Solutions (India) Pvt. Ltd.,

    THANK YOU

    20