Performance Evaluation of an Installed Insulated Tension

System

M.J. Augustyniak, T.D. McCoy, T.M. Connell and S. Gellin

Page 2: Performance Evaluation of an Installed Insulated Tension System M.J. Augustyniak, T.D. McCoy, T.M. Connell and S. Gellin

Dedmon Center, Radford University, Radford, VA USA

Original Construction

•Built 1987

•Air supported fabric with liner

•Fabric coverage: Gym – 4800 m2

Pool – 560 m2

Page 3: Performance Evaluation of an Installed Insulated Tension System M.J. Augustyniak, T.D. McCoy, T.M. Connell and S. Gellin

Problems

•High energy consumption (air conditioning, supporting the air supported roof)

•Poor acoustics in the gym; could not use as a multi-use facility

•Condensation on the pool liner, causing dirt stains

Page 4: Performance Evaluation of an Installed Insulated Tension System M.J. Augustyniak, T.D. McCoy, T.M. Connell and S. Gellin
Page 5: Performance Evaluation of an Installed Insulated Tension System M.J. Augustyniak, T.D. McCoy, T.M. Connell and S. Gellin

New Build Requirements

•State code required a level of insulation not met by old system (R = 12) (0.47 W/m2-°K)

•New insulated system will maintain the natural daylight

•In gym, air supported system replaced by a truss support structure with the insulated fabric system as cladding; flexibility required to protect roof supports

Page 6: Performance Evaluation of an Installed Insulated Tension System M.J. Augustyniak, T.D. McCoy, T.M. Connell and S. Gellin

Properties of New Insulated System

•Top layer: PTFE coated fiberglass

•Bottom layer (liner): PTFE coated fiberglass; special vapor barrier for pool

Page 7: Performance Evaluation of an Installed Insulated Tension System M.J. Augustyniak, T.D. McCoy, T.M. Connell and S. Gellin

Properties of New Insulated System (continued)

•Inside: Aerogel blanket- Lightest solid material on earth- Hydrophobic- Lowest thermal conductivity of any

solid- Translucent- Stable properties- Made from silica- Re-usable

Page 8: Performance Evaluation of an Installed Insulated Tension System M.J. Augustyniak, T.D. McCoy, T.M. Connell and S. Gellin

Gym: Thermal Performance

Page 9: Performance Evaluation of an Installed Insulated Tension System M.J. Augustyniak, T.D. McCoy, T.M. Connell and S. Gellin

Gym: Lighting

Page 10: Performance Evaluation of an Installed Insulated Tension System M.J. Augustyniak, T.D. McCoy, T.M. Connell and S. Gellin

Gym: Acoustical Performance

Conventional Construction vs. Tensotherm Roof(Occupied)

Page 11: Performance Evaluation of an Installed Insulated Tension System M.J. Augustyniak, T.D. McCoy, T.M. Connell and S. Gellin

Pool: Lighting

Page 12: Performance Evaluation of an Installed Insulated Tension System M.J. Augustyniak, T.D. McCoy, T.M. Connell and S. Gellin

Conclusions

•Energy costs significantly reduced

•Lighting more than adequate

•Acoustic performance in gym allows for multi-function usage

•Fabric can now compete with conventional roofing systems in cold weather climates!